HomeMy WebLinkAbout16060091 Building PlansTOM WOOD
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895MUREDOOG.RD
IVADPROF
ESSIONALENGINEER DENADIINAGERRTSIESTATE OFNo.10200395MEP Engineer
874 Cheltenham Way
Avon, IN 46123
317.506.8151
317.745.5761
gnaengineering@aol.com
GOODERUM & ASSOCIATES ENGINEERING
P:
F:
E:MECHANICAL SPECIFICATIONSGENERAL1.BID INSTRUCTIONS: CONTRACTORS SHALLPROVIDE BASE BID IN STRICT ACCORDANCE WITHDESIGN BASIS EQUIPMENT AND MATERIALS.PROJECT DOES ENCOURAGE COMPETITIVEPRICING AND ALLOWS FOR SUBSTITUTIONS OFEQUIPMENT AND MATERIALS AS ALTERNATEDEDUCTS TO BASIS OF DESIGN BIDS. LIST ALLSUBSTITUTIONS ALONG WITH DEDUCTS OFFEREDON BID. ENGINEER RESERVES THE RIGHT TOREJECT SUBSTITUTIONS FOUND NOT TO BE EQUALTO ITEMS LISTED IN DESIGN BASIS.2.PRIOR TO PROCUREMENT CONTRACTOR SHALLSUBMIT TO ARCHITECT FULL SUBMITTALS FOR ALLENERGY CONSUMING OR PRODUCING ITEMS ANDFOR ALL DUCT ACCESSORIES, INSULATION, VAVBOXES, REGISTERS, GRILLES, DIFFUSERS ANDLOUVERS. SUBMITTALS SHALL BE DELINEATEDWITH TAGS INDICATED ON PRINTS, CONTRACTORSNAME, PROJECT NAME. CLEARLY INDICATE ALLMODEL NUMBERS AND ALL ACCESSORIES ANDOPTIONS BEING PROVIDED. SUBMISSIONS SHALLBE IN PDF FORMAT. ALL EQUIPMENT AND ITEMSSHALL BE PER DESIGN BASIS OR APPROVEDEQUAL. ENGINEER RESERVES THE RIGHT TOREJECT ANY SUBSTITUTE ITEM.3.CONTRACTOR SHALL BE RESPONSIBLE TO VISITTHE SITE TO EXAMINE ALL CONDITIONS THAT MAYIN ANY WAY AFFECT THE EXECUTION OF HIS WORK.HE SHALL ALSO EXAMINE THE DRAWINGS ANDSPECIFICATIONS FOR OTHER BRANCHES OF WORKMAKING REFERENCE TO THEM FOR DETAILS OFEXISTING BUILDING CONDITIONS. NO EXTRAS WILLBE ALLOWED FOR FAILURE TO INCLUDE ALLREQUIRED WORK IN THE BID. CONTRACTOR SHALLGUARANTEE ALL LABOR AND MATERIALS ENTERINGINTO CONTRACT FOR A PERIOD OF ONE (1) YEARFROM DATE OF ACCEPTANCE.4.THE DRAWINGS IN THIS SECTION AREDIAGRAMMATIC AND ARE NOT INTENDED TODEFINE EXACT QUANTITIES, LOCATIONS ORCODIFIED REQUIREMENTS. DRAWINGS SHOWGENERAL INTENT OF SYSTEMS. M.C. SHALLPROVIDE AND PAY FOR ALL REQUIRED PERMITS.5.UPON COMPLETION OF THE MECHANICALINSTALLATION, DEMONSTRATE TO THE ENGINEERAND THE OWNER'S SATISFACTION THAT THESYSTEMS HAVE BEEN INSTALLED IN ACCORDANCEWITH THE DRAWINGS, SPECIFICATIONS ANDAPPLICABLE CODES. DEMONSTRATE THE DYNAMICOPERATION OF EACH SYSTEM. VERIFY PROPEROPERATION OF EQUIPMENT, FILTERS ARE CLEANAND COMPONENTS OF THE SYSTEM AREINSTALLED AND ADJUSTED IN FULL ACCORDANCEWITH MANUFACTURER RECOMMENDATIONS.6.ALL WORK SHALL BE IN FULL ACCORDANCE WITH2014 INDIANA MECHANICAL CODE (2012INTERNATIONAL MECHANICAL CODE), INDIANAENERGY CODE (ASHRAE 90.1-2007) PERTINENTSTATE, COUNTY, CITY CODES AND ORDINANCESAND INDIANA AMENDMENTS.DUCTWORK1.CONCEALED ROUND DUCTWORK SHALL BECONSTRUCTED PER SMACNA LOW PRESSURESTANDARDS 1" PRESSURE CLASS, 5' MAXIMUMJOINT LENGTHS, SEAL CLASS B LONGITUDINALSEAM SNAP LOCK PIPE AND ADJUSTABLE FITTINGS.2.EXPOSED ROUND DUCTWORK (OR WHERE SPIRALIS INDICATED ON THE PLANS) SHALL BE LINDAB OREQUAL GALVANIZED STEEL CONFORMING TO ASTMSTANDARDS A653 AND A924 GASKETED SPIRALDUCTING WITH NO SEALER. EDPM RUBBER GASKETSHALL BE U.L. CLASSIFIED RATING OF FLAMESPREAD 0 AND SMOKE DEVELOPED 5 INACCORDANCE WITH ASTM STANDARD E84-91ASMACNA LEAKAGE CLASS 3. FITTINGS SHALL BEMANUFACTURED USING ONE OR MORE OF THEFOLLOWING CONSTRUCTION METHODS:OVERLAPPED EDGES STITCH WELDED ALONG THEENTIRE LENGTH OF THE FITTING, STANDING SEAMGORE LOCKED AND INTERNALLY SEALED, BUTTONPUNCHED AND INTERNALLY SEALED. ELBOWS3-INCH THROUGH 12-INCH DIAMETER WILL BE DIESTAMPED AND CONTINUOUSLY STITCH WELDED.3.PROVIDE SHEET METAL 90 FOR ALL TURNS DO NOTUSE FLEXIBLE DUCT FOR GREATER THAN 45 DEGCHANGES IN DIRECTION. PROVIDE MANUALBALANCING DAMPERS FOR ALL SUPPLY AIR RUNS.ROUND DAMPERS SHALL BE SECURED ON BOTHSIDES OF DUCT AND SHALL CONTAIN LOCKINGHANDLE. SPIRAL DUCTS SHALL USE SPIRAL STYLEDAMPERS WITH FULL WIDTH SHAFT AND NYLONBEARINGS AT EACH END. RECTANGULAR DUCTSSHALL USE MULTI OR SINGLE BLADE WELDEDFRAMED DAMPERS WITH JACK SHAFTS ANDLOCKING HANDLE. INSTALL NYLON RIBBON ON ALLDAMPER HANDLES TO AID IN LOCATION OFDAMPER.4.INSULATED FLEXIBLE DUCTING FOR STRAIGHTCONNECTIONS SHALL NOT EXCEED 7 FEET.FLEXIBLE DUCT EQUAL TO FLEXIBLE DUCT CLASS 1AIR DUCT, DOUBLE LAMINATED POLYESTER FILMON STEEL WIRE REINFORCING, INSULATED WITHSCRIM REINFORCED METALIZED POLYESTEROUTER FIRE RETARDANT JACKET. R-4.2 FORCONDITIONED SPACES AND R-6.0 FOR ANY SPACESOUTSIDE BUILDING THERMAL ENVELOPE.5.RECTANGULAR DUCTWORK SHALL BECONSTRUCTED IN ACCORDANCE WITH SMACNALOW PRESSURE DUCT STANDARDS, +/- 1.0" W.C.)520$670$$0 G-90 COATEDGALVANIZED SHEET STEEL. SEAMS SHALL BEPITTSBURGH CONSTRUCTION, NO BUTTON PUNCHOR SNAP LOCK SEAMS ARE ACCEPTABLE. SEAL ALLTRANSVERSE AND LONGITUDINAL SEAMS WITHWATER BASED DUCT SEALER, SEAL CLASS B.GAUGE AND JOINT CLASSIFICATIONS ACCEPTABLEARE AS FOLLOWS, ALL SECTION LENGTHS ARE 48"MAXIMUM, REFER TO SMACNA RIGIDITY TABLESFOR GAUGES ON LONGER SECTIONS IF REQUIRED:< 12"26 GAUGE, FLAT S AND DRIVE12"-24"24 GAUGE, FLAT S AND DRIVE25"-34"22 GAUGE, STANDING S AND FLATDRIVE34"-40"22 GAUGE, STANDING S ANDSTANDING DRIVE>40"REFER TO SMACNA FOR STANDARDS.6.DUCT HANGERS: COMPLY WITH SMACNA'S "HVACDUCT CONSTRUCTION STANDARDS - METAL AND)/(;,%/(&+$37(5+$1*(56$1'SUPPORTS." PROVIDE GALVANIZED MINIMUM 22GAUGE 1" WIDE STRAP TO HANG RECTANGULARDUCTWORK SMALLER THAN 30" WIDE. DUCTHANGERS FOR RECTANGULAR SHEET METALDUCTS 30" AND LARGER SHALL BE TRAPEZE STYLEUSING UNI-STRUT AND 3/8" OR 1/2" ROD. PROVIDEGRIPPLE, DURODYNE OR EQUAL CABLE HANGERSFOR HANGING ROUND DUCTWORK. SUPPORT ALLHANGERS FROM STRUCTURE PER SMACNASTANDARDS.HANGERS FOR SPIRAL DUCTSGREATER THAN 28" IN DIAMETER SHALL BE HUNGWITH ROD AND DUCT CLAMP. FLEXIBLE DUCTINGSHALL BE SUPPORTED USING MINIMUM 2" WIDENYLON STRAP. ALL INTERVALS ARE PER SMACNA.7.TYPE I HOOD EXHAUST DUCTWORK SHALL BECONSTRUCTED IN ACCORDANCE SPECIFICATIONSON PROJECT SPECIFIC HOOD DRAWINGS. PROVIDEA GREASE DUCT PROTECTION SYSTEM FROM THEPOINT AT WHICH THE DUCT PENETRATES ACEILING, WALL, OR FLOOR TO THE OUTLETTERMINAL, SUCH GREASE DUCT PROTECTIONSYSTEMS SHALL BE CLASSIFIED AND LABELEDMATERIAL, SYSTEM, METHOD OF CONSTRUCTION,OR PRODUCT SPECIFICALLY EVALUATED FOR SUCHPURPOSE AND APPROVED BY THE CODE OFFICIAL.DUCT ACCESSORIES1.COORDINATE WITH ARCHITECTURAL DRAWINGSAND PROVIDE FIRE AND FIRE AND SMOKEDAMPERS AT FIRE RATED ASSEMBLYPENETRATIONS IN ACCORDANCE WITH THEINTERNATIONAL BUILDING CODE.DUCT INSULATION2.ALL DUCT INSULATION MATERIALS SHALL HAVE AFLAME SPREAD RATING OF 25 OR LESS (ON THEFLAME SPREAD TEST SCALE) AND SMOKEDEVELOPMENT OF 50 OR LESS (ON THE SMOKETEST SCALE) OR AS DEFINED BY NFPA 255STANDARD METHOD OF TESTING OF SURFACEBURNING CHARACTERISTICS OF BUILDINGMATERIALS, LOCAL CODES AND LOCALAUTHORITIES HAVING JURISDICTION. DUCT WRAPSHALL BE FIBERGLASS MATERIAL PER ASTMC-411,ASTM C-1104,ASTM C665, ASTM C-1338, ASTME-84, UL723, NFPA 90A,CAN/ULC S102-1188,ASTMC1290, ASTM C553, ASTM C1136.3.INSULATION: INSTALL ALL INSULATION IN STRICTACCORDANCE WITH MANUFACTURERSINSTRUCTIONS IN A TIGHT AND NEAT MANOR. NOSAGGING, FRAYED OR TORN INSULATION WILL BEEXCEPTED. UNLESS OTHERWISE NOTED ON PLANSDUCTWORK SHALL BE INSULATED AS FOLLOWS:SA/RA-1-1/2" FIBERGLASS DUCT WRAP WITHFSK FACING, 75 #/FT3 MINIMUMAPPLIED R-3.5 INSTALLED IN STRICTACCORDANCE WITH MANUFACTURERSREQUIREMENTS.SA/RAIN UNCONDITIONED OR ATTIC SPACESOUTSIDE THE BUILDING INSULATIONENVELOPE; 2" MINIMUM R-6 ASAPPLIED FSK DUCT WRAP.SA/RA-IN RETURN AIR PLENUMS ORCONDITIONED SPACES WHERE NOTCONCEALED BY DRYWALL CEILING ORBULKHEAD CONSTRUCTION WITHINTHE BUILDING INSULATION LINE NONEREQUIRED.SA/RADUCT LINER FOR DUCTS SHALL BE0,1,080´7+,&.'(16,7<PER CU. FT., HAVING MAT FACED ORMONOLITHIC CONSTRUCTION WITHSKIN SMOOTH MICROBIAL SURFACETO WITHSTAND VELOCITIES TO 4000FPM. INSULATION SHALL FIT SNUGLYAGAINST THE INTERIOR DUCTSURFACES, AND BE FASTENED TO THEDUCT WITH A 50% HEAVY COAT OFRECOMMENDED ADHESIVE ANDMETAL FASTENERS WHICH DO NOTPIERCE THE DUCT, SPACED ON´&(17(56$//(;326('('*(6OF THE INSULATION SHALL BECOATED WITH MANUFACTUREDRECOMMENDED ADHESIVEEA- NONE REQUIRED UNLESS NOTED ONPLANS.OA-IN UNCONDITIONED OR ATTIC SPACESOUTSIDE THE BUILDING ENVELOPE;1-1/2" MINIMUM R-3.5 FSK DUCT WRAP.OA-EXPOSED OR IN MECHANICAL ROOMS,1-1/2 FIBERGLASS RIGID BOARDINSULATION WITH FOIL SCRIM LAGGEDWITH 0.024 Al JACKET.OA-IN UNCONDITIONED OR ATTIC SPACESOUTSIDE THE BUILDING ENVELOPE;1-1/2" FIBERGLASS DUCT WRAP WITHFSK FACING, 75 #/FT3 MINIMUMAPPLIED R-4.0 INSTALLED IN STRICTACCORDANCE WITH MANUFACTURERSINSTRUCTIONS.EXTERIOR-ALL PROVIDE LAGGING SYSTEM TOENSURE INSULATION IS PROTECTEDFROM DAMAGE. LAG WITH 0.024 Al,TPO ROOFING, EDPM ROOFING ORPVC JACKET SEALED WATER TIGHT.CHECK TEST AND START UP REQUIREMENTS1.LABEL ALL MAJOR PIECES OF EQUIPMENT WITHLAMACOID PLASTIC, BLACK WITH WHITE LETTERS.SIZE TO BE CONSISTENT WITH EQUIPMENT BEINGLABELED. LENGTH AND WIDTH VARY FORREQUIRED LABEL CONTENT. THERMOSTAT ANDSENSOR LABELS SHALL BE ADJUSTED TO PROVIDEESTHETIC APPEARANCE.2.PROVIDE AIR BALANCE BY CONTRACTOR.CONTRACTOR SHALL BALANCE SUPPLY, RETURN,OUTSIDE, RELIEF AND EXHAUST AIR SYSTEMS INACCORDANCE WITH CURRENT SMACNA, NEEB ORAABC STANDARDS TO DESIGN VALUES ANDPROVIDE WRITTEN REPORT TO ARCHITECT.MECHANICAL CONTRACTOR SHALL BERESPONSIBLE FOR PROVIDING ALL DEVICES,DRIVES, SHEAVES, MOTOR CHANGES AND REWORKAS REQUIRED TO MEET DESIGN REQUIREMENTS.3.MECHANICAL CONTRACTOR SHALL HIREINDEPENDENT THIRD PARTY NEEB, AABC OR PECERTIFIED TEST AND BALANCE (TAB) CONTRACTORWITH MINIMUM OF 5 YEARS EXPERIENCE. TABSHALL BALANCE SUPPLY, RETURN, OUTSIDE AIR,RELIEF AND EXHAUST SYSTEMS IN ACCORDANCEWITH CURRENT SMACNA, NEEB OR AABCSTANDARDS TO DESIGN VALUES AND PROVIDEWRITTEN CERTIFIED REPORT TO ARCHITECT.MECHANICAL CONTRACTOR SHALL BERESPONSIBLE FOR PROVIDING ALL DEVICES,DRIVES, SHEAVES, MOTOR CHANGES AND REWORKAS REQUIRED TO MEET DESIGN REQUIREMENTS.4.MECHANICAL CONTRACTOR SHALL ENSUREEMPLOYEES ARE MEETING AND DOCUMENTING ALLOSHA AND JOB SPECIFIC SAFETY REQUIREMENTSAS REQUIRED BY LAW AND BY CONTRACT.PERSONAL PROTECTIVE EQUIPMENT SHALL BEPROVIDED AND UTILIZED AS REQUIRED.MECHANICAL CONTRACTOR SHALL PAY ALL FINESLEVIED BY OSHA FOR FAILURE TO COMPLY WITHOSHA REQUIREMENTS.5.TEMPERATURE CONTROL WORK SHALL BE THERESPONSIBILITY OF THE HVAC CONTRACTOR.PROVIDE ALL COMPONENTS INCLUDING T/S, T/SWIRE (PLENUM RATED IN RA PLENUMS), SWITCHES,ACTUATORS ETC. AS REQUIRED FOR A COMPLETESYSTEM.PIPING1.PIPING SLEEVES; INTERIOR OR EXTERIOR ABOVEGRADE; GALVANIZED-STEEL-PIPE SLEEVES ORPVC-PIPE SLEEVES. VERIFY, WITH FIREAUTHORITIES HAVING JURISDICTION, THAT PVCMATERIALS ARE ALLOWED FOR SLEEVES. BELOWGRADE; ALL; MECHANICAL GALVANIZED-STEEL PIPESLEEVE SYSTEM LIKE LINK-SEAL. ALL SLEEVESSHALL BE FIRE STOPPED OR CAULKED. EXTERIORSLEEVES SHALL PROVIDE WATER/AIR TIGHTPENETRATION SYSTEM.2.REFRIGERATION PIPING;A.6 TONS AND LARGER CAPACITIES; COPPER, TYPEACR, ANNEALED-TEMPER TUBING ANDWROUGHT-COPPER FITTINGS WITH MINIMUM 15%SIL-FLOS BRAZED JOINTS.B.SYSTEMS 5 TONS OR LESS; MANUFACTUREDREFRIGERANT LINE SETS: ANNEALED-COPPERSUCTION AND LIQUID LINES FACTORYCLEANED,DRIED, PRESSURIZED WITH NITROGEN, SEALED,AND WITH SUCTION LINE INSULATED. PROVIDE INSTANDARD LENGTHS FOR INSTALLATION WITHOUTJOINTS, EXCEPT AT EQUIPMENT CONNECTIONS ORACCESSIBLE LOCATIONS. CONNECTIONS ANDWROUGHT-COPPER FITTINGS WHERE REQUIREDSHALL BE BRAZED WITH MINIMUM 8% SIL-FLOS.C.INSULATION; SUCTION AND ALL DUCTLESS SPLITOR VRF LINES; MINIMUM 1/2" THICK WALLINSULATION SHALL BE A FLEXIBLE, CLOSED-CELLELASTOMERIC PIPE INSULATION, AP ARMAFLEX ORAC ACCOFLEX. ADHESIVE SHALL BE ARMAFLEX 520,520 BLACK OR 520 BLV ADHESIVE. THE INSULATIONMUST CONFORM TO ASTM C534 GRADE 1, TYPE IARMAFLEX AND BE INSTALLED IN STRICTACCORDANCE WITH MANUFACTURERSRECOMMENDATIONS. (3/8" WALL WILL NOT BEACCEPTED).D.ALL INSULATION EXPOSED TO OUTDOORS SHALLBE EITHER PVC LAGGED OR SHALL BE PAINTEDWITH ARMA-FINISH FR UV PROTECTING PAINT.E.LINES SHALL BE RUN KINK FREE AND GENERALLYCONTINUOUS AND AT 90 DEGREE ANGLES TOSTRUCTURE. AVOID JOINTS WHEN POSSIBLE. ALLREQUIRED JOINTS SHALL BE MADE IN ACCESSIBLELOCATIONS OR M.C. SHALL PROVIDE ACCESSPANELS AS NEEDED. ALL BENDS SHALL BE MADEWITH LONG RADIUS FITTINGS OR WITHMECHANICAL BENDING TOOL TO PROVIDE SMOOTHLONG RADIUS TURNS. SUPPORT ALL PIPINGWITHOUT CRUSHING OR DEPRESSING INSULATION.USE REFRIGERATION STYLE CUSH CLAMPSMOUNTED TO STRUT, DO NOT LAY PIPING ONSTRUCTURAL BUILDING MEMBERS. SLEEVE ALLPENETRATIONS AND SEAL WATER TIGHT.F.PRESSURE TEST, TRIPLE EVACUATE AND PREPAREALL PIPING IN STRICT ACCORDANCE WITHMANUFACTURERS RECOMMENDATIONS.ROOF JACK, MATCH ROOF COLORROOF TOP UNITREVOLUTIONS PER MINUTESUPPLY AIR FANRJRPMRTUSAFSTATIC PRESSURESPTCCTSPTOTAL STATIC PRESSUREWALL CAPWCWALK IN COOLERWICWALK IN FREEZERWIFETEXPANSION TANKELECTRIC WATER COOLEREWCTMVTHERMOSTATIC MIXING VALVEAFFABOVE FINISH FLOORURINALSKSINKMOP SINKWATER CLOSETWATER HEATERCOCLEAN OUTPLUMBING CONTRACTORSTORM DRAINVENT THROUGH ROOFSANITARY SEWERSTSTORAGE TANKSDSANCWCOLD WATER DOMESTICPCPRVPSIPRESSURE RELEIF VALVEPOUNDS PER SQUARE INCHMSLAVLAVATORYHWSHWRHOT WATER RETURN DOMESTICHOT WATER SUPPLY DOMESTICGPMGALLONS PER MINUTEWHGCGENERAL CONTRACTORVTRURWCFOOTFTINCHINLEAVING AIR TEMPERATURELINEAR SLOT DIFFUSERMANUALLATIRMANLS1000 BTUHMECHANICAL CONTRACTORMOTOR CONTROL CENTERMBHMCMCCMFRMANUFACTURERPRESSURE DROPPOOL DEHUMIDIFICATION UNITPACKAGE TERMINAL AIR CONDITIONERPOUNDS PER SQUARE INCHPRESSURE RELEIF VALVEPDPDUPTACPSIPRVINFRA-RED AIR HANDLING UNITACCUAHUBOTTOM OF DUCTBACKDRAFT DAMPERBODBDDCOMBUSTION AIRCUBIC FEET PER MINUTECACFMAIR COOLED CONDENSING UNITENTERING AIR WET BULBENTERING AIR DRY BULBROUND EAWBEADBDRY BULBDBELECTRICAL CONTRACTORECELECTRIC WALL HEATEREXHAUST FANEFEWHHOODEXTERNAL STATIC PRESSUREELECTRIC REHEAT COILHESPERCEGEXHAUST GRILLE OR REGISTERFURNACEFCUFFIRE DAMPER OR FLOOR DRAINFIRE AND SMOKE DAMPERFDFD/SDFEET PER MINUTEFPMFAN COIL UNIT ABBREVIATIONSUNLESS OTHERWISE NOTEDUONTEMPERATURE CONTROL CONTRACTORREDUCED PRESSURE ZONED BACKFLOWRPZBFSKFOIL SCRIM VAPOR BARRIERRETURN AIRRASUPPLY AIRSAEACHEAOUTSIDE AIROAVARIABLE AIR VOLUME BOXVAVFAN POWERED VAV BOXFPVAVDEGREES FARENHEITDEG FAIR COOLED CONDENSING UNITMANUAL VOLUME DAMPER LOCKING WITH SHAFTFIRE DAMPERROUND MOTORIZED DAMPERMCOMBINATION FIRE/SMOKE DAMPERTHERMOSTATLAY-IN EXHAUST GRILLEROOF EXHAUST FANTURNING VANES DOUBLE THICKNESSSYMBOLSXXXX-#EQUIPMENT SYMBOLSFDFDSDROOF TOP UNITW/DW/DECHHORIZONTAL FURNACE OR FC WITHDRAIN PANHORIZONTAL AIR COOLED CONDENSING UNITRECTANGULAR CENTERED DUCT TRANSISTIONRECTANGULAR ECCENTRIC DUCT TRANSITION WALL MOUNTED EXHAUST FANLAY-IN SUPPLY AIR DIFFUSERLAY-IN RETURN AIR REGISTER OR GRILLESURFACE MOUNTED SUPPLY AIR DIFFUSERDUCT MOUNTED ROUND DIFFUSERLINEAR OR SLOT DIFFUSERROOF MOUNTED INTAKE/EXHAUST HOODRECTANGULARROOF MOUNTED INTAKE/EXHAUST HOODROUNDSURFACE MOUNTED SUPPLY AIR DIFFUSERCEILING MOUNTED EXHAUST FANMODULAR AIR HANDLING UNITAHUACCUREFIHRHIHRHFCFACEFEFRTUCEILING MOUNTED ELECTRIC HEATERDIFFUSER SYMBOLSDUCT SYMBOLSDIRECT DUCT MOUNTED REGISTERDIFFUSER TAGEWHELECTRIC WALL HEATERECCENTRIC SQUARE TO ROUND TRANSITIONCENTERED SQUARE TO ROUND TRANSITIONSHEET METAL DUCT WIDTH BY DEPTHLINED SHEET METAL DUCT FREE AREA WIDTHBY DEPTH.ACCESS DOORSQUARE SHEET METAL 90 PROVIDE WITHDOUBLE THICKNESS TURNING VANES.RADIUS SHEET METAL 90, R=1.5*DROUND HIGH EFFICIENCY BRANCH DUCTTAKE OFF ON ROUND DUCT.ROUND TAP BRANCH DUCT TAKE OFF ONROUND DUCT.HIGH EFFICIENCY BRANCH DUCT TAKE OFFON RECTANGULAR.STANDARD ROUND TAP BRANCH DUCT TAKEOFF ON ROUND DUCT.SQUARE SHEET METAL 90 PROVIDE WITHDOUBLE THICKNESS TURNING VANES.FULL BODY ROUND TEE FITTINGCONTROL SYMBOLSTHERMOSTAT IN LOCK BOXSENSORCARBON MONOXIDE SENSORCARBON DIOXIDE SENSORNITROGEN OXIDE SENSORMRECTANGULAR MOTORIZED DAMPERDIRECT DUCT MOUNTED REGISTERMARKCFMTTSCOCO2NO
TOM WOOD
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895MUREDOOG.RD
IVADPROF
ESSIONALENGINEER DENADIINAGERRTSIESTATE OFNo.10200395MEP Engineer
874 Cheltenham Way
Avon, IN 46123
317.506.8151
317.745.5761
gnaengineering@aol.com
GOODERUM & ASSOCIATES ENGINEERING
P:
F:
E:ROUND CHIMNEY TOPNOTEFLASHINGROOFSTORM COLLARMETAL ROOFAIR SPACE AROUND FLUEHEATER FLUERADIANT FLUE DETAILNO SCALEALISTEDB-VENT TO HEATER.CONNECT TO APPLIANCE STAINLESS STEEL SINGLE WALLFLUE PIPING SLOPE AT MINIMUM 1/4" PER FOOTROOF DECKFAN HOUSINGEXHAUSTSECURE WITHPREFABRICATED CURB WITH FOR CONTINUATION.DUCTWORK SEE PLANSBACKDRAFT DAMPERINSULATIONEXHAUST FAN DETAIL NO SCALEB#10 SCREWS 12" O.C.PERIMETER SUPPORTANGLES, 2" X 2" X 5/16"TACK TO ROOFFRAMING.12" HIGH PRE-FABRICATEDROOF CURB BY FANMANUFACTURER.PROVIDE NEOPRENEGASKET AND ENSUREAIR TIGHT SEAL ATCURB NAILER.INSTALL PERMANUFACTURER'SRECOMMENDATIONS ANDROOFING CONTRACTORSINSTRUCTIONS.CEILING FAN MOUNTING DETAILNO SCALEC16' FAN WEIGHT = 200 LBS.FAN MOUNTING BRACKETS,BOLTS, WASHERS AND SAFETYCABLE BY FAN MANUFACTURER.Per Fan Specifications16' FAN WEIGHT = 200 LBS.1/4" MOUNTING PLATE BOLTED TOSTRUCTURAL MEMBER OR 3X3ANGLES.(2) BACK TO BACK 3 X 3 X 5/16 ANGLESBOLTED TO ROOF JOIST BY M.C.SECTION AAAA6'-0" MAXIMUM. CONSULTSTRUCTURAL ENGINEER IF SPANIS GREATER THAN 6'-0"3 X 3 X 5/166863(16,212/0 GA CHAIN(TWISTED LINK,PLATED) TYPICAL.EYE HOOKCHAIN('U' TYPE SHOWN)* THESE ANGLES TO BE EQUAL$1'127025(7+$1****SLOPE DOWNWARDS TOWARDS BURNER BY APPROXIMATELY 1/2"MAXINFRA RED HEATER DETAILSNO SCALEDWHERE CHAIN SUPPORTS HAVEAN ANGLE OF INCLINATIONGREATER THAN 15 DEG. ANEQUAL AND OPPOSITESUPPORT IS RECOMMENDED.NOTE:REFER TO MANUFACTURERSINSTALLATION INSTRUCTIONSAND INSTALL HEATER INACCORDANCE WITH ALLCLEARANCE AND INSTALLATIONRECOMMENDATIONS.VERTICAL SUSPENSION CHAINIDEAL WHERE SUPPORTS AREINCLINED. MAXIMUMRECOMMENDED ANGLE OFINCLINATION IS 15 DEG.BEAM CLAMP
TOM WOOD
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895MUREDOOG.RDIVADPROF
ESSIONALENGINEER DENADIINAGER
RTSIESTATE OFNo.10200395MEP Engineer
874 Cheltenham Way
Avon, IN 46123
317.506.8151
317.745.5761
gnaengineering@aol.com
GOODERUM & ASSOCIATES ENGINEERING
P:
F:
E:DIFFUSER, REGISTERS AND GRILLESDESCRIPTIONTAGMFRMODELCFMMAT'L.MOUNTINGSTYLENOTES:S-1S-2S-324"X24" LAY-IN DIFFUSER - 6" NECKPRICEPRICEPRICESCDSTL0-120130-220230-400LAY-INPAINT AREA BEHIND GRILLE FLAT BLACK.COLOR: WHITE24"X24" LAY-IN DIFFUSER - 8" NECK24"X24" LAY-IN DIFFUSER -10" NECKS-5S-6SCDSCDSTLSTLLAY-INLAY-INS-40-1000R-1PRICE24/24 PERFORATED GRILLE10STLLAY-N24/12 PERFORATED GRILLER-20-500PRICE10STLLAY-IN30"X24" BAR FACE GRILLER-32400PRICE530STLSURFACEE-18"X8" BAR FACE0-150E-2PRICE630AlSURFACE12"X12" BAR FACE0-350E-3PRICE630AlSURFACESONESESPCFMTYPE FAN ANDDESCRIPTIONEXHAUST FAN SCHEDULETAGMODEL #LOCATIONFLAMOTOR DATAHPRPMVOLTNOTESEF-10WATTSFAN DATARPM1GREENHECKWATTSSERVICE BAYCF-1NOTESVOLTRPMHPMOTOR DATALOCATIONMODEL #TAGCEILING FAN SCHEDULEDESCRIPTIONTYPE FAN ANDBIG ASS FAN 11PROVIDE WITH WALL MOUNTED CONTROLLER AND ALL REQUIRED MOUNTING HARDWARE.16', POWERFOIL X2.03460951.516' CEILING FANPROVIDE WITH CERRUS MOTOR STARTER CONTAINING DISCONNECT, HAND OFF AUTO SWITCH, PILOT LIGHTS AND DAMPER INTERLOCK.0-300PRICE6"X6" MODULAR CORE DIFFUSERSMDSURFACESTL0-500PRICERNDSTLDUCT0-300PRICESDG-16X4STLDUCT500PRICE630AlSURFACE16"X8" BAR FACE2111ROUND DIFFUSER NECK PER PLANSDUCT MOUNTED DIFFUSER111116"X8" BAR FACE GRILLER-4550PRICE530STLSURFACE111111122222FCU-3ARNU543BRA45400015.836140017.991819/1678/1395208-230/60/1FCU-4Multi V Indoor unitMARKBtu/hMODELTYPECOOLINGFANPIPING CONNECTIONS (inch)POWERkWTYPEAIR FLOW(CFM)LIQUIDGASDRAIN (ID)9+]HEATINGBtu/hkWPOWER INPUT (kW)CoolingHeatingNOTESDuct High StaticARNU763B8A4Duct High Static7640022.408600025.20Sirocco Fan2260/1766/17660.750.753/83/4Sirocco Fan1"1"208-230/60/10.450.453/85/8GAS-FIRED RADIANT HEATER SCHEDULEMARKCONFIGURATIONHEATING DATAELECTRICAL DATAUNITWEIGHT(LBS)MANUFACTURER WITHMODEL NUMBERNOTESINPUTMBHFUEL TYPELENGTH(FT)AMPSVOLTSPHRH1NOTESPLEASE PROVIDE THE FOLLOWING ACCESSORIES1 BALL VALVE AND STAINLESS STEEL FLEX GAS CONNECTOR2 4", 16GA. ALUMINIZED STEEL TUBING3STAINLESS STEEL REFLECTORS4 STAINLESS STEEL REFLECTOR END CAPS5 PROVIDE SMART COM LOW VOLTAGE ZONED THERMOSTATS, SEE PLANS64" VENT ADAPTER & OUTSIDE COMBUSTION AIR ADAPTERS7HANGING CHAIN SETS (CHAIN, KARABINER CLIPS, BEAM CLAMPS, EYE BOLTS)NOTE:A. SIDEWALL REFLECTORS - INCLUDE WHERE SHOWN ON DRAWING8PROVIDE WATERPROOF THERMOSTAT COVER FOR WASH BAY HEATERSSTRAIGHT TUBE150NAT. GAS52'1.21201210AMBIRADVSUSN150-ER-S501-7AMBIRAD GX22-S201-4, 6-8RH4STRAIGHT TUBE75NAT. GAS22'1.2120121011PROVIDE NEW FCU WITH THERMOSTAT AND CONNECT TO EXISTING VRF SYSTEM. ADJUST CHARGE PER LG AND CONNECT TO EXISTING NETWORK.S-70-300PRICESDG-16X4STLDUCT1DUCT MOUNTED DIFFUSERS-80-200PRICESDS-075STLLAY-IN148" x 2 SLOT LINEAR DIFFUSER3MOUNT SLOT DIFFUSER IN ARMSTRONG CEILING SYSTEM COORDINATE WITH CEILING CONTRACTOR.3S-90-200PRICE520STLLAY-IN112X6 DOUBLE DEFLECTION REGISTER3EF-11G-123-VGBELT DRIVE.12515008.41/2ECM115---COMPRESSOR EXHAUST1G-123-VGBELT DRIVE.55008.41/2ECM115---CAR WASH HALL VENTILATION12PROVIDE WITH BIRD SCREEN AND BAKED ENAMEL PAINT, COLOR TO BE SELECTED BY ARCHITECTGREENHECKLV-1NOTES:MODELMFRDESCRIPTIONTAGLOUVERSJ BLADE EXTRUDED ALUMINUM HEAVY GAUGEEXTERIOR CHANNEL FRAME LOUVERSIZE48/48FREEAREA FT2CFM60006.011EF-1GB-240BELT DRIVE.12560001711750460-730COMPRESSOR EXHAUST312PROVIDE WITH CERRUS MOTOR STARTER CONTAINING DISCONNECT, HAND OFF AUTO SWITCH, PILOT LIGHTS AND COOLING ONLY LINE VOLTAGE THERMOSTAT.GREENHECKLV-2J BLADE EXTRUDED ALUMINUM HEAVY GAUGEEXTERIOR CHANNEL FRAME LOUVER30/3015003.01
16/1230/1416/148/14
20/1426/1630/18IR-EIR-E12/1210/108/6 10/10
10/10Up toEF-48/14
8/14
14/12
8/14
8/14
8/14 12/14
8/14 12/14 8/12
8/1412/14
8/14 EF-1Up20/20200S-230/18
LV-EMMS18/18 16/16
20/16 IR-1IR-1IR-120/16Up to Mezz20/16
20/16T16/8Up to20/12 16/12 12/12
TTTTTTTSmart ComIR ControllerTT7\S7\SMezzCF-2CF-2Route Thru Joist
Route Thru JoistCU-2FCU-3CU-2FCU-2CU-1FCU-5CU-1FCU-2CU-1FCU-5CU-2
FCU-3
CU-2
FCU-3
CU-2FCU-5CU-3FCU-2CU-3FCU-53/8:5/8RSRSRS RSRS
CU-2
FCU-3
20/16CU-2FCU-4RSRSRSRSRSRS
RS3/8:3/4RS200S-2200S-2100S-1300S-3200S-2200S-2400S-3400S-3400S-318/1418/12 16/121100R-11500R-x300S-x300S-x200S-220/14
Typ.Typ.250S-2250S-2TT200S-x200S-x1100R-1200S-x100S-x100S-x100S-x100S-x100S-x100S-x350S-x350S-x200S-2275S-x100S-x150S-6200S-8Typ of (8)320S-8Typ of (5)300S-318/1212/12
Typ.200S-2200S-9200S-9400R-4Typ.EXTEND EXISTING VRF PIPING AND INSTALL NEWFAN COIL AS SHOWN. REPORT FINAL LENGTH OFPIPING EXTENSION TO LG AND ADD REQUIREDREFRIGERANT TO NETWORK. EXTEND NETWORK,INSTALL NEW THERMOSTAT AND ADDRESS NEWFCU ON EXISTING SYSTEM.REMOVE (3) EXISTING 12" NECK DIFFUSERS ANDREPLACE WITH (5) NEW DIFFUSERS AS SHOWN.CONNECT TO EXISTING MAIN DUCT WITH NEWBRANCH RUN AND BALANCE TO CFMS AS LISTED.RELOCATE EXISTING 16" RA GRILLE. REMOVEOTHER 16" RA GRILLE AND EXTEND DUCTING ASSHOWN. CONNECT TO (4) NEW RA GRILLES IN NEWOFFICES AS SHOWN.REMOVE, CLEAN AND REINSTALL EXISTINGSUPPLY/RETURN AIR DIFFUSER IN NEW CEILINGSYSTEM. REBALANCE CFMS ON AS SHOWN.COORDINATE WITH ARCHITECTURAL RCP.REMOVE EXISTING DIFFUSER AND BRANCH DUCTBACK TO MAIN AND PATCH AIR TIGHT.REMOVE EXISTING LAY-IN SUPPLY AIR DIFFUSERSAND BRANCH DUCTING. INSTALL NEW TAKE OFFSAND BRANCH DUCTS TO NEW DIFFUSERS IN NEWCEILING SYSTEM. COORDINATE WITH ARCHITECTSRCP.INSTALL NEW TAKE-OFF AND BRANCH DUCT TONEW LAY-IN SUPPLY AIR DIFFUSER.REWORK EXISTING DUCTING AND PROVIDE NEWDIFFUSERS AS SHOWN TO ACCOMMODATE FORNEW TIRE CAROUSEL AND EXPANDED PARTS AREAROUTE NEW STAINLESS STEEL DOUBLE WALLFIREPLACE FLUE ABOVE CEILING AND OUTTHROUGH ROOF. COORDINATE REQUIREMENTSWITH FIREPLACE VENDOR.INSTALL REGISTER 4" ABOVE CAT WALK.COORDINATE WITH FRAMING. REFERENCEARCHITECTURAL SECTIONS FOR MOREINFORMATION.KEY NOTES:1.REFERENCE SHEET M-001 FOR LEGENDS, ABBREVIATIONS,SPECIFICATIONS AND NOTES.2.REFERENCE SHEET M-002 AND M-003 FOR INSTALLATION DETAILS3.PRIOR TO ROUGH IN, COORDINATE TEMPERATURE CONTROLRACEWAYS WITH E.C. M.C. TO PROVIDE ALL CONTROLS AND LOWVOLTAGE CABLES, E.C. TO PROVIDE ALL MOTOR STARTERS,RACEWAYS AND LINE VOLTAGE CONDUCTORS.GENERAL NOTES:11SCALE: 3/32" = 1'-0"FIRST FLOOR HVAC PLAN - AREA 'A'TOM WOOD
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895MUREDOOG.RDIVADPROF
ESSIONALENGINEER DENADIINAGERRTSIESTATE OFNo.10200395MEP Engineer
874 Cheltenham Way
Avon, IN 46123
317.506.8151
317.745.5761
gnaengineering@aol.com
GOODERUM & ASSOCIATES ENGINEERING
P:
F:
E:2NKEY PLANAAA3412344444445656447741188799101010
%220
TO BE MOUNTED
TO CEILING 20566 SQFTLV-E181" bot of steelIR-EMIR-EIR-EWH-E1291 FT24 ton 322 ft/tonFuture space 1200ft2, need taps for 5ton ducted unitPHASE 2 -6500 FT216 TONS400 ft2/t2400 CFM24/12 14/1016/10Up toEF-712/12RSRSRS3/8:5/8CU-1
FCU-3
1-1/4"RH-44"4" FlueTTUp B-vent4" FlueUp B-ventRH-1CF-1CF-1EF-1RH-18000 FT2600 MBH RADIANTHEATING, 6000 CFMEXH. COCONTROLLEDLV-1MRSRSRS3/8:5/8RH-4W.C.4"W.C.RH-44"6" FlueUp B-ventRH-4W.C.4"W.C.6" FlueUp B-ventVSCOSVSMSTTTTTTEWH500R-4500R-4RH-1500R-44" FlueUp B-vent16/8 Upto EF-11M.C. TO PROVIDE AND INSTALL BAF AS SCHEDULED.EXPOSED ROUND DUCTWORK SHALL BE GASKETEDSPIRAL DUCTWORK LIKE LINDAB. MOUNTDIFFUSERS ON DUCT PER DETAIL ON M003.IR HEATERS SHALL BE SIMULTANEOUSLYCONTROLLED BY SMARTCOM MULTIZONE IRTEMPERATURE CONTROL PANEL WITH REMOTEBLACK BULB AND OA SENSOR. RACEWAYS FOR TCCAND BURNER/BLOWER INTERLOCKS ARE BY E.C.ALL CONTROLS AND HEATER COMPONENTS BY M.C.TYPICAL.VRF NETWORK WIRING BY M.C. RACEWAYS FROMSINGLE GANG BOX IN WALL TO ACCESSIBLECEILING SPACES OR IDUS BY .E.C. GROUP UNITSWHERE SHOWN. SEE SHEETS M502 AND M503 FORWIRING DIAGRAMS. TYPICAL.M.C. TO PROVIDE AND INSTALL BAF AS SCHEDULED.IR HEATERS SHALL BE SIMULTANEOUSLYCONTROLLED BY SMARTCOM MULTIZONE IRTEMPERATURE CONTROL PANEL WITH REMOTEBLACK BULB AND OA SENSOR. RACEWAYS FOR TCCAND BURNER/BLOWER INTERLOCKS ARE BY E.C.ALL CONTROLS AND HEATER COMPONENTS BY M.C.TYPICAL.PACKAGED SNOWMELT SYSTEM. SEE P-103 FORCONTINUATION.KEY NOTES:1.REFERENCE SHEET M-001 FOR LEGENDS, ABBREVIATIONS,SPECIFICATIONS AND NOTES.2.REFERENCE SHEET M-002 AND M-003 FOR INSTALLATION DETAILS3.PRIOR TO ROUGH IN, COORDINATE TEMPERATURE CONTROLRACEWAYS WITH E.C. M.C. TO PROVIDE ALL CONTROLS AND LOWVOLTAGE CABLES, E.C. TO PROVIDE ALL MOTOR STARTERS,RACEWAYS AND LINE VOLTAGE CONDUCTORS.GENERAL NOTES:11SCALE: 3/32" = 1'-0"FIRST FLOOR HVAC PLAN - AREA 'B'TOM WOOD
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895MUREDOOG.RDIVADPROF
ESSIONALENGINEER DENADIINAGERRTSIESTATE OFNo.10200395MEP Engineer
874 Cheltenham Way
Avon, IN 46123
317.506.8151
317.745.5761
gnaengineering@aol.com
GOODERUM & ASSOCIATES ENGINEERING
P:
F:
E:2NKEY PLANB3456565777
11'-0"9'-8"131'-7"ST54'-9"10'-6"495 ft @ 12 in282 ft @ 12 in287 ft @ 12 in
279 ft @ 12 in245 ft @ 12 inPexROUTE TO 2ND FLOORIN FLOOR MECHANICALROOM AREA EQUIPMENT(SEE M-200 FOR CONTINUATION)1-1/4" S/R1SCALE: 3/32" = 1'-0"SHOW ROOM FLOOR HEATINGTOM WOOD
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895MUREDOOG.RDIVADPROF
ESSIONALENGINEER DENADIINAGERRTSIESTATE OFNo.10200395MEP Engineer
874 Cheltenham Way
Avon, IN 46123
317.506.8151
317.745.5761
gnaengineering@aol.com
GOODERUM & ASSOCIATES ENGINEERING
P:
F:
E:NKEY PLAND3SCALE: NONEINFLOOR PIPING DETAILHYDRONIC HEATING DETAILSCAPACITYDESCRIPTIONAREA FLOOR HEATINGFT2MBTUHNUMBEROF LOOPSLOOPSPACING1750GPMLOOPSLOOPPIPINGFTDP-FT512" maxType A5/8" hepexM-1A/SFSLEGEND:2SCALE: N.T.S.FLOOR HEAT PIPING DIAGRAM ET RP-1P-1B-138.03900.827.7GPM4.1TOTALSEE PLANS FOR LOOP LAYOUTS AND ZONE LENGTHS.CONTACT BAKER SPECIALTIES, 317-407-0187 KENSHOCKLEY FOR FLOOR HEAT PACKAGE PRICING. ALLCOMPONENTS ARE BY M.C., RACEWAYS ARE BY E.C ANDPROGRAMMING AND STARTUP IS BY VENDOR.TYPICAL TUBING TIE DOWN4' TYPCONCRETE SLABINSULATION BOARD BYHEATING CONTRACTORSHALL BE INSTALLED UNDERSLABS AND AT EXTERIORWALL EDGES OF SLABS FORALL AREAS CONTAININGFLOOR TUBING.SENSOR TUBINGROUTE TO WALLTHERMOSTAT.COORDINATE WITH E.C.4"MAXREBAR AND WIRE MESHGRID ELEVATED ONNSTAND OFFS. PLANE TO BEAPPROXIMATELY CENTEROF SLAB DEPTH.SECURE PIPING WITH STAPLES ANDOR WIRE TIES, PRESSURIZE PRIORTO POUR AND MONITOR PRESSUREDURING CONCRETE POURSEQUENCE OF OPERATIONBOILER1.BOILER SHALL BE ENABLED BELOW 40 (ADJ) OA TEMP.2.ON CALL FOR FLOOR HEAT, FIRE BOILER AND MAINTAIN 120(ADJ) WATER TEMPERATURE.3.BOILER CONTROL SHALL BE INTEGRAL WITH BOILERPACKAGE.FLOOR HEAT1.TEKMAR 538 THERMOSTAT SHALL ENABLE FLOOR HEATBASED ON ROOM SET POINT AND SLAB TEMPERATURE.2.UPON ENABLE THERMOSTAT WILL START P1 FIRE BOILERAND CYCLE PUMP TO MAINTAIN SLAB TEMPERATURESETPOINT.5/8" PEX TUBINGO2 BARRIER TYPE3/4"ET BOILER1-1/4"CNDCNDCND CNDCNDCNDCNDCNDCNDCND EXHCA3/4" PVC DRAIN PRVCND HOSEFS-2TO FLOOR DRAIN3" PVC ROUTE UP THROUGHROOF JACKS PERMANUFACTURERSRECOMMENDATIONS.TEKMAR 538 FLOOR HEATXFRMSOAB-1THERMOSTATCW3/4"BY P.C.A/S1-1/4"P-1RSM25 loopsFLOOR HEAT1-1/4"SLAB 1S1-1/4"KEY NOTES:1.REFERENCE SHEET M-001 FOR LEGENDS,ABBREVIATIONS, SPECIFICATIONS AND NOTES.2.COORDINATE ALL IN SLAB HEAT PIPING WITH INFLOOR MOUNTED DEVICES. ROUTE PIPINGAROUND THESE LOCATIONS AS NEEDED.COORDINATE WITH GENERAL CONTRACTOR.3.INSTALL SHUT OFF VALVES ON AND UNIONS ONSUPPLY AND RETURN OF ALL COMPONENTS.GENERAL NOTES:1(5) 5/8" LOOPS FROM S/R MANIFOLDS. PIPELOOPS UNDER SLAB. FEED OVER CEILING FROMMECHANCAL ROOM AND DOWN CHASE TOMANIFOLDS. SEE SHEET M201 FORCONTINUATION FROM MECH ROOM ABOVE.SENSORS, CONDUIT BY E.C. WIRING BY SLABHEATING CONTRACTOR.221UPONOR A2670501 (5) PORT SUPPLY ANDRETURN MANIFOLD, WALL MOUNTED,INTEGRAL BALANCING VALVES/GAUGES.AIR SEPERATOR: CALEFFI 551035A 1-1/4"DISCAL AIR SEPARATOR.COMBINATION AUTO FILL/BACKFLOW VALVE:CALEFFI 57309A W/GAUGEEXPANSION TANK - EXTROL 30BOILER CIRCULATION PUMP: GRUNDFOSCAST IRON UPS26-99F-MED, 15 GPM @ 3.0 FT.ZONE CIRCULATION PUMP: GRUNDFOS CASTIRON UPS, 3.1 GPM @ 20 FT.WALL MOUNTED HIGH EFFICIENCY BOILER:TRIANGLE TUBE PA80, 80 MBH NATURAL GAS,WITH INPUT MODULATION, 95% AFUE.
%220
TO BE MOUNTED
TO CEILING
Circuit 5
350 ft
Circuit 6
350 ft
Circuit 7
325 ft
Circuit 8
316 ft
Circuit 1
316 ft
Circuit 2
325 ft
Circuit 3
350 ft
Circuit 4
350 ft M3M230'22'-4"22'-4"29'-7"SSSSOASnow MeltController6" FlueDwn B-vent6" FlueDwn B-vent6" FlueUp B-vent6" FlueUp B-ventEF-2EF-1BoilerP2BP2GLYHWSHWSHWS HWS HWS HWS HWS HWS HWS HWS HWS HWS HWS HWS HWS HWS HWS
HWRHWRHWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR
1-1/4"HWSHWR14/10LV-1MTTCOORDINATE DROPWITH CAR WASHEQUIPMENT1SCALE: 3/32" = 1'-0"CAR WASH SNOW MELT AND MECH VENTILATIONTOM WOOD
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895MUREDOOG.RDIVADPROF
ESSIONALENGINEER DENADIINAGERRTSIESTATE OFNo.10200395MEP Engineer
874 Cheltenham Way
Avon, IN 46123
317.506.8151
317.745.5761
gnaengineering@aol.com
GOODERUM & ASSOCIATES ENGINEERING
P:
F:
E:NKEY PLAND3SCALE: NONECAR WASH PAD DETAILSKEY NOTES:1.REFERENCE SHEET M-001 FOR LEGENDS,ABBREVIATIONS, SPECIFICATIONS AND NOTES.2.COORDINATE ALL IN SLAB HEAT PIPING WITH INFLOOR MOUNTED DEVICES. ROUTE PIPINGAROUND THESE LOCATIONS AS NEEDED.COORDINATE WITH GENERAL CONTRACTOR.3.INSTALL SHUT OFF VALVES ON AND UNIONS ONSUPPLY AND RETURN OF ALL COMPONENTS.GENERAL NOTES:1(4) 5/8" LOOPS FROM S/R MANIFOLDS. PIPELOOPS UNDER SLAB. FEED MAINS DOWN FROMMECH ROOM ABOVE.CARWASH SNOWMELT HEATING DETAILSCAPACITYDESCRIPTIONAREA FT2MBTUHNUMBEROF LOOPSLOOPSPACING6605GPMLOOPSLOOPPIPINGType A5/8" hepexFTDP-FTSNOW MELT 1 100.06" max296.1.4414.2GPM7.2TOTALSEE PLANS FOR LOOP LAYOUTS AND ZONE LENGTHS.TYPICAL TUBING TIE DOWN4' TYPCONCRETE SLABINSULATION BOARD BYFLOOR HEAT CONTRACTORSHALL BE INSTALLED UNDERSLABS AND AT EXTERIORWALL EDGES OF SLABS FORALL AREAS CONTAININGFLOOR TUBING.SENSOR TUBINGROUTE TO WALLTHERMOSTAT.COORDINATE WITH E.C.4"MAXREBAR AND WIRE MESHGRID ELEVATED ON STANDOFFS. PLANE TO BEAPPROXIMATELY CENTEROF SLAB DEPTH.SECURE PIPING WITH STABLES ANDOR WIRE TIES, PRESSURIZE PRIORTO POUR AND MONITOR PRESSUREDURING CONCRETE POURSEQUENCE OF OPERATIONBOILER1.BOILER SHALL BE ENABLED BELOW 40 (ADJ) OA TEMP.2.ON CALL FOR SLAB HEAT, FIRE BOILER AND MAINTAIN 120(ADJ) WATER TEMPERATURE.3.BOILER CONTROL SHALL BE INTEGRAL WITH BOILERPACKAGE.4.CALL FOR HEAT SHALL OCCUR AT TEMPERATURES BELOW35 AND SNOW/RAIN OR OCCUPIED HOURS.5/8" PEX TUBINGO2 BARRIER TYPE6605SNOW MELT 2 100.06" max296.1.447.2Type A5/8" hepex1A/SCW3/4"3/4"ET1-1/4"1-1/4"BOILER1-1/4"CNDCNDCND CNDCNDCNDCNDCNDCNDCND EXHCA3/4" PVC DRAIN PRVCND HOSEFS-2TO FLOOR DRAINBP-2P-2GLYCOLFEEDERRSM25 loopsSNOW MELTGLYPVC ROUTE UP THROUGHROOF JACKS PERMANUFACTURERSRECOMMENDATIONS.RSM34 loops1-1/4"TEKMAR 654 SNOW SRAIN/SNOWSLAB 1SMELT CONTROLLERXFRMSSLAB 2SOAB-1SOUTSIDE AIR1-1/4"FILL STATIONBY P.C.1-1/4"3SCALE: NONECAR WASH PAD HEAT PIPING DIAGRAM2(5) 5/8" LOOPS FROM S/R MANIFOLDS. PIPELOOPS UNDER SLAB. FEED MAINS DOWN FROMMECH ROOM ABOVE.SENSORS, CONDUIT BY E.C. WIRING BY SLABHEATING CONTRACTOR.23333SLOOP TEMPLEGEND:14.2M-2A/SAIR SEPERATOR: CALEFFI 551035A 1-1/4" AIRSEPARATOR.FSCOMBINATION FILL/BACKFLOW VALVE:CALEFFI 57301 W/GAUGEM-3GLYGLYCOL FEEDER - AXIOM MF200 PRESSUREPAL MINI FEEDER.ETEXPANSION TANK - EXTROL 30BP-2BOILER CIRCULATION PUMP: GRUNDFOSCAST IRON UPS26-99F-MED, 15 GPM @ 3.0 FT.P-2SNOW MELT CIRCULATION PUMP: GRUNDFOSCAST IRON UPS26-99F-MED, 15 GPM @ 20 FT.BOILERWALL MOUNTED HIGH EFFICIENCY BOILER:TRIANGLE TUBE SOLO PA175, 175 MBHNATURAL GAS WITH INPUT MODULATION, 96%AFUE.UPONOR A2670401 (4) PORT SUPPLY ANDRETURN MANIFOLD, WALL MOUNTED,INTEGRAL BALANCING VALVES/GAUGES.UPONOR A2670501 (5) PORT SUPPLY ANDRETURN MANIFOLD, WALL MOUNTED,INTEGRAL BALANCING VALVES/GAUGES.
INOUTHR2ARSRSRSRS RS
RS RSRSINOUTHR3ARS RS RS RSRSRSRSRS RS RSRSRSRSRSRSRSRSRS
1/2:7/8:1+1/83/8:3/43/8:5/83/8:5/83/8:5/83/4:1+1/8:1+3/8IN OUT
HR3A
3/8:5/83/8:5/83/8:5/83/8:5/85/8:7/8:1+1/83/4:1+1/8:1+5/83/8:5/83/8:5/83/8:5/83/8:5/83/4:1+1/8:1+3/81/2:7/8:1+1/8RSRSRSRSRSRS3/8:5/8DOWN3/8:5/8DOWNDOWN TO UNITS CU-3FCU-1CU-3FCU-4CU-3FCU-2CU-3FCU-2CU-3FCU-2RSRSRSRSRSRSRSRSRSTO CU-3 SEEM300 FORCONTINUATIONRSRSRSRSTO CU-2 SEEM300 FORCONTINUATIONFLOOR HEAT
EQUIPMENT
TO INFLOOR HEATING SYSTEM(SEE M-102 FOR CONTINUATION)1SCALE: 3/32" = 1'-0"SECOND FLOOR VRF PIPING PLANTOM WOOD
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895MUREDOOG.RDIVADPROF
ESSIONALENGINEER DENADIINAGERRTSIESTATE OFNo.10200395MEP Engineer
874 Cheltenham Way
Avon, IN 46123
317.506.8151
317.745.5761
gnaengineering@aol.com
GOODERUM & ASSOCIATES ENGINEERING
P:
F:
E:REMOVE 410A REFRIGERANT, RELOCATE VRFCONDENSER FARM, REPIPE AS SHOWN, RECHARGE PERLG LATS AND RESTART. ALL PIPING SHALL BE INSTALLEDPER LG REQUIREMENTS. PRIOR TO RELOCATION VERIFYALL SIZES AND LENGTHS AGAINST LATS SUBMITTAL. SEEM300 FOR NEW CONDENSER FARM LOCATIONS.COORDINATE ALL WORK WITH G.C. AND ROOFER.SLEEVE PIPING PENETRATION ABOVE COUNTERFLASHING AND SEAL WATER TIGHT.FLOOR HEATING EQUIPMENT LOCATION. SEE SHEET M102FOR DETAILS.1.REFERENCE SHEET M-001 FOR LEGENDS, ABBREVIATIONS,SPECIFICATIONS AND NOTES.2.REFERENCE SHEET M-002 AND M-003 FOR INSTALLATION DETAILS3.PRIOR TO ROUGH IN, COORDINATE TEMPERATURE CONTROLRACEWAYS WITH E.C. M.C. TO PROVIDE ALL CONTROLS AND LOWVOLTAGE CABLES, E.C. TO PROVIDE ALL MOTOR STARTERS,RACEWAYS AND LINE VOLTAGE CONDUCTORS.GENERAL NOTES:KEY NOTES:12NKEY PLANAAC1233
EF-4CU-11,2C8CU-31,2,&3C9C8
3/4:1+1/8:1+5/81/2:3/4:1+1/85/8:1+1/8:1+3/85/8:1+1/8:1+3/81/2:7/8:1+1/83/8:3/4:7/83/8:3/4:7/81/2:7/8:1+1/8MAU13400 CFM1.0 SP75 deg dt1534 LBAC-1FlueEF-3FlueFlueACCUACCUEF-2EF-11168 LBS1884 LBSFlueFlueFlueFlueFlueFlueFlueFlueFlueFlueFlueFlueReliefHoodFlueFlueFlueExhaust VentFlueFlueFlueEF-7CapEF-8CU-31,2,&3C9C8
3/4:1+1/8:1+5/81/2:3/4:1+1/85/8:1+1/8:1+3/83/8:3/4:7/81/2:7/8:1+1/81884 LBSCU-21,2C85/8:7/8:1+1/83/4:1+1/8:1+3/85/8:7/8:1+1/81256 LBSROOF ADDITIONROOF ADDITIONROOF ADDITIONROOF ADDITIONROOF ADDITIONFlue6" FlueEF-11EF-106" Flue4" Flue4" Flue4" FlueEXISTING RTU ABANDON IN PLACE TO BE REMOVEDTO ACCOMMODATE NEW ROOFING. COORDINATEWITH ROOFING CONTRACTOR.KEY NOTES:11SCALE: 3/32" = 1'-0"ROOF HVAC PLAN TOM WOOD
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895MUREDOOG.RDIVADPROF
ESSIONALENGINEER DENADIINAGERRTSIESTATE OFNo.10200395MEP Engineer
874 Cheltenham Way
Avon, IN 46123
317.506.8151
317.745.5761
gnaengineering@aol.com
GOODERUM & ASSOCIATES ENGINEERING
P:
F:
E:EXISTING ACCU AND PITCH POCKET ABANDON INPLACE TO BE REMOVED TO ACCOMMODATE NEWROOFING. COORDINATE WITH ROOFINGCONTRACTOR. TO BE REMOVED.2NEW FLUE SEE FLASHING DETAIL ON SHEET M00234KEY NOTES:5EXISTING VRF CONDENSER FARM ON EQUIPMENTRAILS TO BE RELOCATED FROM HIGH ROOF TO LOWROOF AS SHOWN. PROVIDE NEW EQUIPMENT RAILSAS REQUIRED. COORDINATE RELOCATION WITHROOFING CONTRACTOR.NEW STAINLESS STEEL DOUBLE WALL FIREPLACEFLUE, COORDINATE REQUIREMENTS WITH FIREPLACEVENDOR.NKEY PLANBAAADAAC1.PROJECT INTENT: THIS IS THE SECOND PHASE OF A MULTI PHASE PROJECT.UNDER THIS PHASE NEW ADDTIONS ARE BEING ADDED TO THE EXISTINGBUILDING AND ROOF IS BEING REPLACED. REFERENCE ARCHITECTURAL PLANSFOR MORE INFORMATION. EXISTING ROOF TOP UNITS ABANDON ON PREVIOUSPHASES ARE BEING REMOVED ON THIS PHASE.2.REFERENCE SHEET M-001 FOR LEGENDS, ABBREVIATIONS, SPECIFICATIONS ANDNOTES.3.EXISTING CONDITIONS ARE BASED ON LIMITED SURVEYS AND AS BUILTDRAWINGS. PRIOR TO BID CONTRACTOR SHALL REVIEW ALL PLANS, PERFORMSITE VISIT AND MAKE ADJUSTMENTS TO BID AS REQUIRED TO MEET INTENT OFPROJECT.GENERAL NOTES:11111113NEW EXHAUST FAN. SEE FLASHING DETAIL ONSHEET M002.335566344
1WALL SECTION 3WALL SECTION 2WALL SECTION 4WALL SECTIONNPAA321PMM.1N.2 ADETAIL MM.1 5WALL SECTIONM.9KEY NOTES:KEY NOTES: (CONT.)EXISTING BUILDING:A321DATA
REV.
DATA
DWG.
TOM WOODTOM WOOD
AUTOMOTIVE GROUP
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895
ARCHITECTS
YALAB
TCETIHCRA YALAB
SNAVELEAHCIM880149
No.
STATE OF
ANAIDNI DE
RETSIGER GENERAL NOTES:
1WALL SECTION 2WALL SECTION 3WALL SECTIONMM.1M.9NN.2QQM.9 4WALL SECTION4
A322 7.48.2KEY NOTES:KEY NOTES: (CONT.)EXISTING BUILDING:A322DATA
REV.
DATA
DWG.
TOM WOODTOM WOOD
AUTOMOTIVE GROUP
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895
ARCHITECTS
YALAB
TCETIHCRA YALAB
SNAVELEAHCIM880149
No.
STATE OF
ANAIDNI DE
RETSIGER GENERAL NOTES:
1WALL SECTION 2WALL SECTION 3WALL SECTION 4WALL SECTION10.888.154.90.5AA3231.2 ADETAIL KEY NOTES:KEY NOTES: (CONT.)EXISTING BUILDING:A323DATA
REV.
DATA
DWG.
TOM WOODTOM WOOD
AUTOMOTIVE GROUP
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895
ARCHITECTS
YALAB
TCETIHCRA YALAB
SNAVELEAHCIM880149
No.
STATE OF
ANAIDNI DE
RETSIGER GENERAL NOTES:
1WALL SECTION 2WALL SECTION 3WALL SECTION1.20.51.221.9KEY NOTES:KEY NOTES: (CONT.)EXISTING BUILDING:A324DATA
REV.
DATA
DWG.
TOM WOODTOM WOOD
AUTOMOTIVE GROUP
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895
ARCHITECTS
YALAB
TCETIHCRA YALAB
SNAVELEAHCIM880149
No.
STATE OF
ANAIDNI DE
RETSIGER GENERAL NOTES:
1WALL SECTION 2WALL SECTION 3WALL SECTION10.91110.911KEY NOTES:KEY NOTES: (CONT.)EXISTING BUILDING:A325DATA
REV.
DATA
DWG.
TOM WOODTOM WOOD
AUTOMOTIVE GROUP
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895
ARCHITECTS
YALAB
TCETIHCRA YALAB
SNAVELEAHCIM880149
No.
STATE OF
ANAIDNI DE
RETSIGER GENERAL NOTES:
1WALL SECTION 2WALL SECTION 3WALL SECTION 4WALL SECTIONA.7KEY NOTES:KEY NOTES: (CONT.)EXISTING BUILDING:A326DATA
REV.
DATA
DWG.
TOM WOODTOM WOOD
AUTOMOTIVE GROUP
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895
ARCHITECTS
YALAB
TCETIHCRA YALAB
SNAVELEAHCIM880149
No.
STATE OF
ANAIDNI DE
RETSIGER GENERAL NOTES:
1WALL SECTION 2WALL SECTION 3WALL SECTION 4WALL SECTION12.112.1KEY NOTES:KEY NOTES: (CONT.)EXISTING BUILDING:A327DATA
REV.
DATA
DWG.
TOM WOODTOM WOOD
AUTOMOTIVE GROUP
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895
ARCHITECTS
YALAB
TCETIHCRA YALAB
SNAVELEAHCIM880149
No.
STATE OF
ANAIDNI DE
RETSIGER GENERAL NOTES:
1WALL SECTION 2WALL SECTION 3WALL SECTION 4WALL SECTIONKEY NOTES:KEY NOTES: (CONT.)EXISTING BUILDING:A328DATA
REV.
DATA
DWG.
TOM WOODTOM WOOD
AUTOMOTIVE GROUP
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895
ARCHITECTS
YALAB
TCETIHCRA YALAB
SNAVELEAHCIM880149
No.
STATE OF
ANAIDNI DE
RETSIGER GENERAL NOTES:
KEY NOTES:KEY NOTES: (CONT.) 2WALL SECTION 1WALL SECTION 3WALL SECTION 4WALL SECTION1.11A01A 5WALL SECTION12.112CB.7EXISTING BUILDING:A329DATA
REV.
DATA
DWG.
TOM WOODTOM WOOD
AUTOMOTIVE GROUP
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895
ARCHITECTS
YALAB
TCETIHCRA YALAB
SNAVELEAHCIM880149
No.
STATE OF
ANAIDNI DE
RETSIGER GENERAL NOTES:
KEY NOTES:KEY NOTES: (CONT.) 1WALL SECTION 2WALL SECTION 3WALL SECTION 5SCUPPER SECTION13A03A03 4WALL SECTIONEXISTING BUILDING:A330DATA
REV.
DATA
DWG.
TOM WOODTOM WOOD
AUTOMOTIVE GROUP
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895
ARCHITECTS
YALAB
TCETIHCRA YALAB
SNAVELEAHCIM880149
No.
STATE OF
ANAIDNI DE
RETSIGER GENERAL NOTES:
KEY NOTES:KEY NOTES: (CONT.) 1WALL SECTION1.1 2SCREEN WALL SECTIONEXISTING BUILDING:A331DATA
REV.
DATA
DWG.
TOM WOODTOM WOOD
AUTOMOTIVE GROUP
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895
ARCHITECTS
YALAB
TCETIHCRA YALAB
SNAVELEAHCIM880149
No.
STATE OF
ANAIDNI DE
RETSIGER GENERAL NOTES:
KEY NOTES:STAIR NOTES:KEY NOTES: (CONT.) EXTERIOR STAIR PLANN
E
A333
1A3321A332E
A333
EXISTING BUILDING:A332DATA
REV.
DATA
DWG.
TOM WOODTOM WOOD
AUTOMOTIVE GROUP
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895
ARCHITECTS
YALAB
TCETIHCRA YALAB
SNAVELEAHCIM880149
No.
STATE OF
ANAIDNI DE
RETSIGER GENERAL NOTES:
KEY NOTES:EXTERIOR REVEALS DETAILACM PANEL BASE DETAILACM PANEL SOFFIT DETAILACM PANEL PLAN DETAIL AT OVERHEAD DOORACM WINDOW HEAD DETAILKEY NOTES: (CONT.)GUARD RAIL ANCHORAGEEXISTING BUILDING:A333DATA
REV.
DATA
DWG.
TOM WOODTOM WOOD
AUTOMOTIVE GROUP
3003 E. 98th Street Suite 201
Indianapolis, IN 46280 (317) 574-0143
Fax (317) 573-9895
ARCHITECTS
YALAB
TCETIHCRA YALAB
SNAVELEAHCIM880149
No.
STATE OF
ANAIDNI DE
RETSIGER GENERAL NOTES: