Loading...
HomeMy WebLinkAbout17020120 Building PlansMAIN STREET POKE 110 West Main Street, Ste. 106 Carmel, IN 46032 PROJECT #.0 100303 DATE: 1-24-1 7 _. P PLAN NORTH SITE MAP: VICINITY MAP: ABBREVIATIONS 1-1 INDEX SHEET, BUILDING CODE DATA, SITE AND VICINITY PLAN A-1 DEMOLITION PLAN FLOOR PLAN LIFE SAFETY PLAN WITH NOTES A.F.F ABOVE FINISHED FLOOR FE FIRE EXTINGUISHER R RISER ACT ACOUSTICAL CEILING TILE FEC FIRE EXTINGUISHER CABINET RA RETURN AIR APP APPROXIMATE GA GAUGE RB RESILIENT BASE AWT ACOUSTICAL WALL TREATMENT GB GRAB BAR REF REFERENCE BLKG BLOCKING GWB GYPSUM WALL BOARD REFR REFRIGERATOR B..O. BOTTOM OF HDWR HARDWARE READ REQUIRED BOT BOTTOM HM HOLLOW METAL RO ROUGH OPENING CAB CABINET HORIZ HORIZONTAL SA SUPPLY AIR CPT CARPET HVAC HEATING, VENTILATING, AIR CONDITIONING SCHED SCHEDULE CJ CONTROL JOINT HW HOT WATER SEC SECTION CL CENTER LINE JST JOIST SIM SIMILAR CMU CONCRETE MASONRY UNIT JT JOINT SPECS SPECIFICATIONS COL COLUMN KIT KITCHEN SA SUPPLY AIR CONC CONCRETE LAM LAMINATE SF SQUARE FOOT CONST CONSTRUCTION LAV LAVATORY SS STAINLESS STEEL CONT CONTINOUS LLH LONG LEG HORIZONTAL STD STANDARD CT CERAMIC TILE LLV LONG LEG VERTICAL STL STEEL CW COLD WATER MAS MASONRY SUSP SUSPENDED DET DETAIL MAX MAXIMUM TB TACK BOARD DF DRINKING FOUNTAIN MB MARKER BOARD TEL TELEPHONE DIM DIMENSION MECH MECHANICAL T.O. TOP OF DRWGS DRAWINGS MEZZ MEZZANINE TV TELEVISION EA EACH MFR MANUFACTURER TYP TYPICAL EC EXPOSED CEILING MIN MINIMUM UON UNLESS OTHERWISE NOTIFIED EJ EXPANSION JOINT M.O. MASONRY OPENING UR URINAL EIFS EXTERIOR INSULATION FINISH MATERIAL OD OUTSIDE DIAMETER VCT VINYL COMPOSITION TILE EL ELEVATION OPNG OPENING VERT VERTICAL EWC ELECTRIC WATER COOLER OPP OPPOSITE VT VINYL TILE EXIST EXISTING O.H. OPPOSITE HAND W/ WITH EXP EXPANSION O.T.O OUT TO OUT W/O WITHOUT EXT EXTERIOR PL PLASTIC LAMINATE WB WOOD BASE FD FLOOR DRAIN PLWD PLYWOOD WC WALL COVERING FIN FINISH PT PORCELAIN TILE WD WOOD FLR FLOOR PS PROJECTION SCREEN WH WATER HEATER FT FEET QT QUARRY TILE WP WORKING POINT INDEX SHEET 1-1 INDEX SHEET, BUILDING CODE DATA, SITE AND VICINITY PLAN A-1 DEMOLITION PLAN FLOOR PLAN LIFE SAFETY PLAN WITH NOTES A-2 DEMO RCP AND RCP NOTES AND LEGEND A-3 DETAILS AND CROSS-SECTIONS A -3a ELEVATIONS A-4 WALL TYPE AND DOOR SCHEDULE A-5 FINISH PLAN AND SCHEDULE A-6 EQUIPMENT PLAN AND SCHEDULE E-1 FLOOR PLAN- ELECTRICAL WORK M-1 FLOOR PLAN- MECHANICAL WORK P-1 FLOOR PLAN- PLUMBING WORK BUILDING CODE DATA OCCUPANCY CLASSIFICATION: A-2 ASSEMBLY OCCUPANCY LOAD: OCCUPANCY LOAD SUMMARY: UNCONCENTRATED AT 15 SF/PERSON= 484 SF= 32 Scole NTS STANDING AT 5 SF/PERSON= 254 SF= 50 3 TOILET,ACCESS. USE AT 100 SF/PERSON= 199 SF= 2 KITCHEN AT 200 SF/PERSON= 385 SF= 1 TOTAL OCCUPANT LOAD = 85 PEOPLE CONSTRUCTION TYPE: CONSTRUCTION TYPE LEVELS P2,P19 1- TYPE IA LEVELS 2,3,4, MEZZ: IA SEPARATION PROVIDED BETWEEN FIRST FLOOR AND 3 FLOORS ABOVE: 2 HOUR 4 STORY WITH MEZZANINE, FULLY SPRINKLED REMODELED AREA: 19480 SQ. FT. TOTAL BUILDING AREA: 599200 SQ. FT. FIRST FLOOR PLUMBING FIXTURES AN EXISTING UNISEX RESTROOM WITHIN THE REQUIRED: TENANT SPACE WILL BE MAINTAINED. ADDITIONAL PUBLIC TOILET FACILITIES (SEPARATE SEX) ARE EXISTING WITHIN 500 FEET IN AN ADJACENT BUILDING UNDER THE SAME OWNERSHIP AS PERMITTED BY TABLE 2902.1, FOOTNOTE "J" AND SECTION 2902.3.2. THE EXISTING PUBLIC FACILITIES ARE ACCESSED BY AND ACCESSIBLE ROUTE OF 263 FT THROUGH AN EXISTING OPEN COURTYARD AND WILL BE AVAILABLE AT ALL TIMES THE RESTAURANT IS OCCUPIED AS REQUIRED BY SECTION 2902.3.1. Project Name and Address MAIN STREET POKE 110 WEST MAIN STREET SUITE 106 CARMEL, IN 46032 Firm Name and Address Lehner Designs 1290 Old Heritage Place Greenwood. ln,&ana 46143 317.888.7086 www.lehn,erdesigns.com THIS DRAWING SET IS PROVIDED IN CONFIDENCE AND SHALL BE USED ONLY AS INTENDED BY THE AGREEMENT WITH LEHNER DESIGNS. NO OTHER USE OR DUPLICATION MAYBE MADE WITHOUT PRIOR WRITTEN CONSENT OF LEHNER DESIGNS. ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLY RESERVED. INDEX SHEET , MH Revision/Issue Date Date 1 /24/17 F4No. 2 Scole NTS 3 INDEX SHEET , MH PLAN NORTH rApproved Date 1 /24/17 Project # 100303 Sheet Date 1 /24/17 Scole NTS 3 DEMOLITION PLAN 2 FLOOR PLAN IFIED 1 -D AS`. E WALI DEMOLITION PLAN KEY NOTES: 1. DEMOLISH EXISTING INTERIOR WALLS, BULKHEADS, DOORS, AND DOOR FRAMES AS SHOWN ON PLAN. SHORE UP ANY REMAINING WALLS AS REQUIRED. ANY EXISTING ELECTRICAL/ DATA WITHIN WALLS BEING DEMOLISHED TO BE TERMINATED BACK TO SOURCE. 2. DEMOLISH EXISTING BUILT-IN CABINETRY, SHELVING, DISPLAY CASES, AND COUNTERTOPS, INCLUDING ANY PLUMBING WITHIN THESE CABINETS. TERMINATE PLUMBING SUPPLY AND DRAIN LINES FLUSH WITH FLOOR AND INSIDE REMAINING WALLS. TERMINATE ANY ELECTRICAL IN THIS CABINETRY BACK TO SOURCE. 3. DEMOLISH EXISTING INTERIOR FINISHES (UNLESS NOTED) ON WALLS, AND FLOORS INCLUDING CARPET, BASE, VINYL TILE, VCT TILE, PALLET WOOD, FINISHED TRIM, SIGNAGE/ GRAPHICS, AND MIRRORS. REMOVE ALL ADHESIVES FROM FLOOR. 4. REFER TO MEP DRAWINGS (ELECTRICAL, MECHANICAL, AND PLUMBING) FOR ADDITIONAL NOTES RELATED TO THAT SCOPE. 5. ALL PLUMBING AND FLOOR RUN ELECTRIC WILL NEED TO BE CORE DRILLED THROUGH THE EXISTING STRUCTURE AND RUN BELOW THE PRECAST. ALL CORE DRILLING THROUGH PRECAST MUST BE COORDINATED WITH STRUCTURAL T'S. ANY DAMAGE TO THE STRUCTURAL CONCRETE WILL BE THE RESPONSIBILITY OF THE TENANT TO REPAIR. 6. EXISTING TILE FLOOR IN VESTIBULE AND RESTROOM TO REMAIN. ONLY THING TO DEMOLISH IN EXISTING RESTROOM IS BASE. 7. EXISTING GRID, CEILING TILE, AND LIGHTING TO BE DEMOLISHED AS INDICATED ON PLAN. REFER TO NEW REFLECTED CEILING PLAN FOR FIXTURES TO BE REUSED IN NEW LOCATIONS. 8. DEMOLISH EXISTING SIDE STEPPED BULKHEADS AND LIGHTING AS INDICATED ON PLAN. CENTRAL LOWER BULKHEAD TO REMAIN. REFER TO NEW REFLECTED CEILING PLAN FOR FIXTURES TO BE REUSED IN NEW LOCATIONS. 9. REMOVE EXISTING FIRE EXTINGUISHER CABINET TO BE RELOCATED PER FLOOR PLAN. 10. REMOVE LIGHTING IN EXISTING LOWER BULKHEAD AS SHOWN ON PLAN. REFER TO NEW REFLECTED CEILING PLAN FOR FIXTURES TO BE REUSED IN NEW LOCATIONS. FLOOR PLAN GENERAL NOTES: NOT ALL NOTES APPLY TO EVERY PROJECT. 1. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL FIELD CONDITIONS AND ALL DIMENSIONS. ANY DISCREPANCY FROM PLANS SHOULD BE BROUGHT TO DESIGNERS ATTENTION. 2. ALL DIMENSIONS ARE TO FACE OF FINISHES, BRICK, MASONRY, OR DRYWALL, UNLESS OTHERWISE NOTED ON PLANS. 3. REFER TO DOOR AND WINDOW SCHEDULES FOR ALL MATERIALS, FINISHES, AND HARDWARE INFORMATION. 4. PROVIDE FIRE BLOCKING AT ANY OPENINGS IN FIRE RATED ASSEMBLIES. 5. PROVIDE FIRE RATED WOOD BLOCKING IN WALLS FOR ANY WALL SUPPORTED ITEMS. 6. ALL ITEMS LOCATED IN THE CEILING PLENUM SHALL BE RATED FOR SUCH INSTALLATION, OR PROTECTED TO PROVIDE COMPLIANCE. THIS INCLUDES BUT NOT LIMITED TO POWER, WIRING, DATA/ TELECOMMUNICATIONS, PLUMBING AND DRAIN LINES, SUPPORT BRACKETS AND WOOD BLOCKING. 7. CONTRACTOR SHALL SUBMIT SAMPLES IN TRIPLICATE OF ALL FINISH MATERIALS FOR DESIGNERS APPROVAL PRIOR TO ORDERING. THE CONTRACTOR IS SOLE RESPONSIBLE PARTY FOR ANY FINISHES ORDERED INCORRECTLY WHEN APPROVALS HAVE NOT BEEN RECEIVED. 8. ALL PLUMBING FIXTURES SHALL BE ADA COMPLIANT. 9. FIRE SUPPRESSION SYSTEM SCOPE BY GENERAL CONTRACTOR. KEY FLOOR PLAN NOTES: 1. INFILL AROUND CORE DRILLS AS NEEDED TO SUPPLY A SMOOTH SURFACE FOR FLOORING MATERIAL. 2. BUILT-IN CABINETRY- REFER TO ELEVATIONS AND REFER TO FINISH PLAN AND SCHEDULE FOR FINISHES. 3. REFER TO WALL TYPES FOR DETAILS ON ALL NEW OR MODIFIED EXISTING WALL TYPE CONSTRUCTION. 4. REFER TO EQUIPMENT PLAN FOR LOCATIONS OF ALL OWNER PROVIDED KITCHEN EQUIPMENT. REFER TO PLUMBING, MECHANICAL, AND ELECTRICAL SHEETS FOR DETAILS ON KITCHEN EQUIPMENT REQUIREMENTS. 1 LIFE SAFETY PLAN -1'-0" :PAIR ALL FLOOR, CEILING, AND WALL SURFACES TO AS NEW CONDITION FOR 'PLICATION OF NEW FINISH MATERIALS. PAINTED WALLS TO HAVE A LEVEL 5 DISH. iR NEW FLOOR DRAIN LOCATIONS REFER TO PLUMBING SHEETS FOR DRAIN AND IPPLY REQUIREMENTS. JILT -IN BENCH SEAT, REFER TO FLOOR PLAN AND SECTION (1,2 /A3) FOR :TAILS. PROVIDE REMOVABALE CUSHIONS PER FINISH SCHEDULE AND .EAN-OUT SECTION ALONG BACK OF SEAT. LOCATED DOOR FROM PREVIOUS STORAGE ROOM )RNER WINDOW WITH PAINTED WOOD FRAMING, BUTT JOINT CLEAR TEMPERED .ASS ON OUTSIDE CORNER AND PROVIDE CLEAR SEALANT, SEE WINDOW :TAIL ELEVATIONS (2/A4) FOR DETAILS. .ISTING FIRE EXTINGUISHER CABINET RELOCATED. INSTALLED SO TOP OF LBINET IS NO HIGHER THAN 60". .W FIRE EXSTINGUISHER CABINET TO MATCH EXISTING. INSTALLED SO TOP OF LBINET IS NO HIGHER THAN 60". OWNER PROVIDED 60" MONITORS, POST MOUNTED OFF OF CEILING. )ORDINATE WITH OWNER ON REQUIREMENTS. MODIFIED TO 2HR RATED ASSEMBLY —SEE WALL TYPES 1/A4 Project Name and Address MAIN STREET POKE 110 WEST MAIN STREET SUITE 106 CARMEL, IN 46032 Firm Name and Address Lehner Designs 1290 Old Heritage Place Greenwood. Indiana 461 3 317,8887086 ^'rVWwr 1ehnerdesigns.com THIS DRAWING SET IS PROVIDED IN CONFIDENCE AND SHALL BE USED ONLY AS INTENDED BY THE AGREEMENT WITH LEHNER DESIGNS. NO OTHER USE OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF LEHNER DESIGNS. ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLYRESERVED. No. Revision/Issue Date 1 [Date 24-17Al 2 3 4 DEMOLITION PLAN FLOOR PLAN LIFE SAFETY PLAN AND NOTES MH/GL PLAN NORTH [Approved [Date 24-17Al 00303 Sheet [Date 24-17Al RIES 1 DEMO REFLECTED CEILING PLAN 3/16"-1'-0" (: 1REFLECTED0" CEILING PLAN 3/16" -1' - DEMOLITION PLAN KEY NOTES: 1. DEMOLISH EXISTING INTERIOR WALLS, BULKHEADS, DOORS, AND DOOR FRAMES AS SHOWN ON PLAN. SHORE UP ANY REMAINING WALLS AS REQUIRED. ANY EXISTING ELECTRICAL/ DATA WITHIN WALLS BEING DEMOLISHED TO BE TERMINATED BACK TO SOURCE. 2. DEMOLISH EXISTING BUILT-IN CABINETRY, SHELVING, DISPLAY CASES, AND COUNTERTOPS, INCLUDING ANY PLUMBING WITHIN THESE CABINETS. TERMINATE PLUMBING SUPPLY AND DRAIN LINES FLUSH WITH FLOOR AND INSIDE REMAINING WALLS. TERMINATE ANY ELECTRICAL IN THIS CABINETRY BACK TO SOURCE. 3. DEMOLISH EXISTING INTERIOR FINISHES (UNLESS NOTED) ON WALLS, AND FLOORS INCLUDING CARPET, BASE, VINYL TILE, VCT TILE, PALLET WOOD, FINISHED TRIM, SIGNAGE/ GRAPHICS, AND MIRRORS. REMOVE ALL ADHESIVES FROM FLOOR. 4. REFER TO MEP DRAWINGS (ELECTRICAL, MECHANICAL, AND PLUMBING) FOR ADDITIONAL NOTES RELATED TO THAT SCOPE. 5. ALL PLUMBING AND FLOOR RUN ELECTRIC WILL NEED TO BE CORE DRILLED THROUGH THE EXISTING STRUCTURE AND RUN BELOW THE PRECAST. ALL CORE DRILLING THROUGH PRECAST MUST BE COORDINATED WITH STRUCTURAL T'S. ANY DAMAGE TO THE STRUCTURAL CONCRETE WILL BE THE RESPONSIBILITY OF THE TENANT TO REPAIR. 6. EXISTING TILE FLOOR IN VESTIBULE AND RESTROOM TO REMAIN. ONLY THING TO DEMOLISH IN EXISTING RESTROOM IS BASE. 7. EXISTING GRID, CEILING TILE, AND LIGHTING TO BE DEMOLISHED AS INDICATED ON PLAN. REFER TO NEW REFLECTED CEILING PLAN FOR FIXTURES TO BE REUSED IN NEW LOCATIONS. 8. DEMOLISH EXISTING SIDE STEPPED BULKHEADS AND LIGHTING AS INDICATED ON PLAN. CENTRAL LOWER BULKHEAD TO REMAIN. REFER TO NEW REFLECTED CEILING PLAN FOR FIXTURES TO BE REUSED IN NEW LOCATIONS. 9. REMOVE EXISTING FIRE EXTINGUISHER CABINET TO BE RELOCATED PER FLOOR PLAN. REFLECTED CEILING PLAN NOTES: 1. CEILING HEIGHTS REFER TO RCP FOR VARIOUS HEIGHTS. 2. NEW BULKHEAD SECTIONS TO TIE IN AND MATCH CONDITIONS OF EXISTING BULKHEAD. 3. PATCH AND REPAIR PREVIOUS DEMOED LIGHTING ON BULKHEAD. REFER TO RCP FOR NEW FIXTURE LOCATIONS. 4. NEW CEILING GRID AND TILE. REFER TO FINISH SCHEDULE. 5. REFER TO MECHANICAL DRAWINGS FOR ALL HVAC DISTRIBUTION INFORMATION. 6. ALL CIRCUITRY/SWITCHING TO BE TIED BACK TO EXISTING ELECTRICAL PANEL IN FLEX SPACE 104. REFER TO ELECTRICAL PLAN SHEET FOR DETAILS. 7. SECURITY AND FIRE ALARM SYSTEM MODIFICATIONS BY GENERAL CONTRACTOR. 8. PROVIDE ALL NEW PRISMATIC TYPE LENS AND NEW LAMPING ON ALL EXISTING 2X4 LIGHT FIXTURES. 9. REWIRE ALL EXISTING LIGHTING AS REQUIRED BY NEW LAYOUT. 10. ANY SUBSTITUTE ON LIGHT FIXTURE TO BE APPROVED BY DESIGNER. 11. OWNER PROVIDED 60" MONITORS. NEW REFLECTED CEILING PLAN LEGEND 2X2 ACOUSTICAL CEILING TILE AND EX./MODIFIED GRID. ACT -1 REFER TO FINISH SCHEDULE. Project Name and Address MAIN STREET POKE 110 WEST MAIN STREET SUITE 106 CARMEL, IN 46032 Firm Name and Address Lehner Designs 1290 Old Heritage Place Greenwood. Indiana 461 3 317,8887086 THIS DRAWING SET IS PROVIDED IN CONFIDENCE AND SHALL BE USED ONLY AS INTENDED BY THE AGREEMENT WITH LEHNER DESIGNS. NO OTHER USE OR DUPLICATION MAYBE MADE WITHOUT PRIOR WRITTEN CONSENT OF LEHNER DESIGNS. ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLY RESERVED. EXISTING 2X4 FLORESCENT LIGHT FIXTURE REPLACE ALL LENS AND LAMPING IN ALL FIXTURES EX—RL O NEW 12" PENDANT LIGHT HILITE MFG—H-15612 96 CORD 6061-0 iNCANDESCENT 200 WATT MAX QTY 2 RCP AND DEMO RCP NOTES AND LEGEND Designed By MH/GL PLAN NORTH Checked By GL EXISTING RELOCATED TRACK LIGHT Approved By [Date 24/2017A2 n n n n ELITE—ET4—WH TRACK QTY 5 EX—RL ET402WH—HEADS QTY 20 DEMOLITION REFLECTED CEILING PLAN LEGEND USHIO XL LIFE MR16—LAMPS QTY 20 2X2 ACOUSTICAL CEILING TILE AND EX./MODIFIED GRID. ACT -1 REFER TO FINISH NEW 4" CEILING DOWNLIGHT SCHEDULE. O ELITE—HH4—LED 4501 900L 120 WD 40K 85+ CL—WH (OR SIMILAR) QTY 19 Revision/Issue Date ® EXISTING CEILING FIXTURENo. NEW 6" CEILING DOWNLIGHT ELITE—FUSION—FC3LV—N-50W—E-120—F—WH—BK QTY 2 0 USHIO XL LIFE MR16—LAMPS QTY 6 ELITE—HH6—LED 6501 90OL—DIMTR 120 WD 40K 85+ CL—SCH (OR SIMILAR) QTY 14 1 n n n n *EXISTING TRACK LIGHT ELITE—ET4—WH TRACK QTY 5 EX—RL QO EXISTING RELOCATED CEILING CAN LIGHT 2 ET402WH—HEADS QTY 20 RL625 14W 120 DIMTR 30K W WH B61C—AT QTY 5 USHIO XL LIFE MR16—LAMPS QTY 20 3 NEW WALL MOUNT ACCENT LIGHT HILITE MFG—H-18112 96 SHADE WITH HL—A MOUNTING ARM 6061-0 INCANDESCENT MAX 200 WATTS QTY 7 4 � EXISTING CEILING MONO POINT WINONA LIGHTING— LED—POPS07—ARR—S-002—DM24V—BAL—STD SMALL QTY 8 LED—POPS07—ARR—M-002—DM24V—BAL—STD MEDIUM QTY 8 OEX EXISTING CEILING CAN LIGHT LED—POPS07—ARR—L-002—DM24V—BAL—STD LARGE QTY 8 RL625 14W 120 DIMTR 30K W WH B61C—AT QTY 5 0 *EXISTING CEILING CAN LIGHTO NEW 16" PENDANT LIGHT ELITE—RL625 14W 120 DIMTR 30K W WH—LED MODULE QTY 12 HILITE MFG—H-15616 96 CORD 6061-0 iNCANDESCENT 200 WATT MAX QTY B61C—AT—HOUSING QTY 12 3 O EXISTING CEILING FIXTURE ® EXISTING RELOCATED EXIT SIGN SOLID DENOTES DIRECTION OF FACEPLATE. ELITE—BL3-50W—M-120-61312—WH— QTY 6 EX—RL USHIO XL LIFE MR16—LAMPS—QTY 6 EXISTING EXIT SIGN . O EXISTING CEILING FIXTURE EX ELITE—BL3-50W—M-120—B1302CL—WH— QTY 9 USHIO XL LIFE MR16—LAMPS QTY 9 NEW EXIT/EMERGENCY LIGHT ® NAVILITE—NXPBA 3 R WH WITH BATTERY BACK—UP. SOLID DENOTES DIRECTION OF FACEPLATE. QTY 3 EXISTING CHANDELIER (FIXTURE REMOVED) NEW EXIT/EMERGENCY LIGHT NAVILITE—NXPCL 3 R WH WITH BATTERY BACK—UP. SOLID DENOTES EXISTING 2X4 FLORESCENT LIGHT FIXTURE DIRECTION OF FACEPLATE. ARROW DENOTES DIRECTION TO EXIT. QTY 1 EMERGENCY LIGHT NAVILITE—N1LWH QTY 2 GENERAL NOTE: — EXISTING LIGHT FIXTURE TO BE DEMOED AND STORED FOR POSSIBLE REUSE. SINGLE SWITCH NL NIGHT LIGHT EXISTING 2X4 FLORESCENT LIGHT FIXTURE REPLACE ALL LENS AND LAMPING IN ALL FIXTURES EX—RL O NEW 12" PENDANT LIGHT HILITE MFG—H-15612 96 CORD 6061-0 iNCANDESCENT 200 WATT MAX QTY 2 RCP AND DEMO RCP NOTES AND LEGEND Designed By MH/GL PLAN NORTH Checked By GL Approved By 00303 Sheet [Date 24/2017A2 6"=1'-0" 3 ASSEMBLY CASEGOOD DETAIL 2 BOOTH CROSS-SECTION 1 "W X 3'-4"H FINISHED WOOD BACK PANEL WITH REMOVABLE CUSHION BACK 1"H X 1'-8"W FINISHED WOOD SEAT WITH EASED EDGE AND CRUMB GRAB AT BACK. PROVIDE BACKING AND SUPPORT AS NEEDED. 1'-5"H X 1'-9"W FULL FINISHED WOOD SUPPORT PANEL AS NEEDED. 2 A3 BUILT—IN STORAGE CABINETS WITH ADJUSTABLE SHELF. SEE ELEVATION 3,5,6,7/A3a AND FINISH PLAN AND SCHEDULE. n Q0 •6, T L &_BO_CASEGOOD DETAIL STORAGE CABINET, 1 /A3a AND FINISH SCHEDULE. SEE ELEVATION PLAN AND BUILT—IN BENCH, SEE AND ELEVATION 1 /A3a REFER TO FINISH PLAN SCHEDULE. SECTION 1 /A3 FOR DETAILS. AND Project Name and Address MAIN STREET POKE 110 WEST MAIN STREET SUITE 106 CARMEL, IN 46032 Firm Name and Address Lehner Designs 1290 Old Heritage Place Greenwood.,Indiana 4614 17.'888 7086 www.lohnerdesigns.com THIS DRAWING SET IS PROVIDED IN CONFIDENCE AND SHALL BE USED ONLY AS INTENDED BY THE AGREEMENT WITH LEHNER DESIGNS. NO OTHER USE OR DUPLICATION MAYBE MADE WITHOUT PRIOR WRITTEN CONSENT OF LEHNER DESIGNS. ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLYRESERVED. DETAILS AND CROSS-SECTIONS / GL Revision/Issue Date 1 F4No. 2 Scale VARIES 3 DETAILS AND CROSS-SECTIONS / GL PLAN NORTH [pproved Project Sheet #100303 Date 1 /24/2017 Scale VARIES 0 I N 7 FEATURE WALL ELEVATION 4 RESTROOM ELEVATION 4'-6„ 9'-11 '/4„ *1 L 1 L 6 POS COUNTER ELEVATION 5 BUFFET ELEVATION -1'-0" MENU WWC Revision/Issue 5 P1 POKE POKE POKE P2 24/2017 F gO (9 4) 4'-0» PL1 3 2 ELEVATION 3'-8)/4„ 4)-0)) S'-6.. -L/2 3 )_MENU WALL ELEVATION -1'-0" 0 14 I RP1 RP1� PL1 PL1 N = RB1 _ LO I 5�PL1 ELEVATION KEY NOTES 1. TEMPERED GLASS SECURED IN U -CHANNEL CENTERED ON SS1 ON TOP OF HALF WALL TO SERVE AS SNEEZE GUARD. 2. FRP TO BE INSTALLED BEHIND BUFFET EQUIPMENT TO PROTECT WALL SURFACE. 3. 4"H SS1 BACKSPLASH TO BE INSTALLED ON WALLS BEHIND ALL BASE CABINETS IN ASSEMBLY AREA. 7 P3 4. ALL INTERIOR DOOR FRAMES AND WINDOW FRAMES TO BE PAINTED o IN A SEMI -GLOSS FINISH IN P2. P1 ^I 5. 60" MONITORS AND ART TO BE SELECTED AND INSTALLED AT A LATER DATE. POKE POKE POKE PL2 6. WINDOW TO WRAP AROUND CORNER. PL1 7. P4 TO BE PAINTED ON THE BULKHEAD. 10 Q0 8. VWC TO BE APPLIED IN A RAILROAD MANNER. CPL P2 9. COMBINATION ELECTRIC/DUAL USB OUTLETS CENTERED IN RB1 WAINSCOTING AT 34"H. 2' - 2" 4 2'-10%4" 10. WAINSCOTING TO HAVE 4"H RAISED RUNS AND 4"W RISERS IN PL1 2'-23/4" WITH WALL BEHIND TO BE PAINTED IN P2. REFER TO KEY FINISH PLAN NOTE A5. 2'-43/ 4 1 BOOTH /CONDIMENT COUNTER ELEVATION 11. SS1 BAR COUNTER TO BE SECURED TO WALL AT 3'-4"H WITH 4"H BACKSPLASH. 12. WAINSCOTING TO HAVE 2"H RAISED RUNS (TO ACCOMODATE SS1) AND 4"W RISERS IN PL1 WITH WALL BEHIND PAINTED IN P2. REFER TO GENERAL FINISH PLAN NOTE A5. 13. WAINSCOTING TO HAVE 4"H RUNS IN PL1 AND NO RISERS. PL1 PANEL TO BE GLUED TO WALL. 14. RP1 SECURED IN U -CHANNEL CENTERED ON SS1 ON TOP OF HALF WALL TO SERVE AS SNEEZE GUARD. Project Name and Address MAIN STREET POKE 110 WEST MAIN STREET SUITE 106 CARMEL, IN 46032 Firm Name and Address Lehrer Des 1290 Old Hedt0ge NaCe Greenwood. Indiana 46143 317 888.7OB6 www.lei nerdes gns.com THIS DRAWING SET IS PROVIDED IN CONFIDENCE AND SHALL BE USED ONLY AS INTENDED BY THE AGREEMENT WITH LEHNER DESIGNS. NO OTHER USE OR DUPLICATION MAYBE MADE WITHOUT PRIOR WRITTEN CONSENT OF LEHNER DESIGNS. ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLYRESERVED. ELEVATIONS MH/GL Revision/Issue Date 1 24/2017 F F4No. 2 3 ELEVATIONS MH/GL PLAN NORTH [Approved a 24/2017 F 00303 Sheet a 24/2017 F "= 1 1-011 3' - 79-599 2 WINDOW DETAIL WALL TYPE 1 "' SOLID SURFACE SILL OVER WOOD SUBSTRATE. z"T RESIN DIVIDER SCREEN WITH ALUMINUM U CHANNEL ATTACHMENT. 2X4 WOOD STUDS AT 16" O.C.. PLASTIC LAMINATE SKIN ON BOTH SIDES. RESILIENT WALL BASE ON BOTH SIDES. 1 WALL TYPES DOOR SCHEDULE DOOR FRAME CODE TYPE SIZE MATERIAL FINISH RATING MATERIAL FINISH TYPE RATING HEAD JAMB HDWRE REMARKS A EX. 3'-0" X 7'-0" ALUM./ GLASS EX. -- EX. ALUMINUM EX. EX. -- -- -- EX. REFER TO HARDWARE NOTE 4 B 1 3'-0" X 7'-0" ALUM./GLASS STANDARD METAL -- WOOD PAINTED 1 -- -- -- 1 TWO WAY SWING C EX -RL 3' X 7'-0" WOOD STAINED -- WOOD PAINTED 1 -- -- -- EX REUSE EXISTING DOOR D EX 3'-0" X 7'-0" WOOD STAINED -- WOOD PAINTED 1 -- -- -- EX EXISTING HARDWARE E EX 3'-0" X 7'-0" ALUM./ GLASS EX -- EX. ALUMINUM EX. 1 -- -- -- EX REFER TO HARDWARE NOTE 4 2' - All 99 103/4 WALL TYPE 2 2X4 WOOD STUDS AT 16" O.C.. PLASTIC LAMINATE SKIN ON OUTSIDE SIDES AND FRP BOARD ON INSIDE. RESILIENT WALL BASE ON BOTH SIDES. Project Name and Address MAIN STREET POKE 110 WEST MAIN STREET SUITE 106 CARMEL, IN 46032 Firm Name and Address Lehrer Des 1290 Old Henit0ge PICa e Greenwood. mw ood. Indianal 46143 312 888.2 10 wwwww leI n ides gns.com THIS DRAWING SET IS PROVIDED IN CONFIDENCE AND SHALL BE USED ONLY AS INTENDED BY THE AGREEMENT WITH LEHNER DESIGNS. NO OTHER USE OR DUPLICATION MAYBE MADE WITHOUT PRIOR WRITTEN CONSENT OF LEHNER DESIGNS. ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLYRESERVED. WINDOW NOTES: —BUTT JOINT OUTSIDE CORNER TEMPERED GLASS —2" WOOD FRAME IN P2. 3'11" FINISHED FLOOR TO BOTTOM OF 3' - OF CLEAR FROM FRAME. WALL TYPE 3 2" SOLID SURFACE SILL OVER WOOD SUBSTRATE. a "T CLEAR TEMPERED GLASS DIVIDER SCREEN WITH POLISHED EDGES AND ALUMINUM U CHANNEL ATTACHMENT. 2X4 WOOD STUDS AT 16" O.C.. PLASTIC LAMINATE SKIN ON OUTSIDE AND FRP BOARD ON INSIDE. RESILIENT WALL BASE ON BOTH SIDES. P.►LlA��7»� TYPE "X" GYPSUM BOARD. DTH SIDES- FINISH TO 4" BOVE ACT CEILING GRID. $" 25 GA. METAL STUDS AT i" O.C.- WALL HEIGHT TO BE J BOTTOM CONCRETE DECK/ EAMS. LL WALL FULL DEPTH WITH DUND ATTENTION BLANKET. EX. $" TYPE "X" GYPSUM BOARD ON BOTH SIDES WITH CONTINUOUS ACOUSTICAL SEALANT BOTH SIDES. EX. 6" 20 GA. METAL STUD AT 16" O.C.- WALL HEIGHT IS TO BOTTOM OF EXISTING CONCRETE DECK/BEAM. EX. 5-1/2" BATT SOUND BATT ATTENTION BLANKET. 2- NEW $" TYPE "X" GYPSUM BOARD ON PROJECT SIDE WITH ATTACHMENT UTILIZING TYPE S SCREWS AND CONTINUOUS ACOUSTICAL SEALANT PROVIDE ADDITIONAL SEALANT AT THE TOP AND BOTTOM OF ALL DEMISING WALLS AND AT ALL PENETRATIONS THROUGH DEMISING WALLS TO BE SURE ANY ODORS FROM THIS PREMISES DOES NOT ENTER THE ADJACENT TENANTS PREMISES. WALL TYPE 5 UL DESIGN U408 (SIMILAR) 2 HOUR RATED ASSEMBLY WALL TYPE AND DOOR SCHEDULE MH/GL SEE rApproved Date 1 /24/2017 SCHED, 1 /4"= 1 1-011 DOOR SCHEDULE NOTES 1. KEEP EXISTING INTERIOR DOOR FROM PREVIOUS STORAGE ROOM FOR REUSE. Q PAINTED HARDWARE NOTES w = WOOD FRAME HARDWARE SET #1 U 3 HINGES 1. ALL NEW DOORS TO RECEIVE STANDARD ADA COMPLIANT LEVER No. Revision/Issue Date 2 PUSH PLATES HANDLES. 2 KICKPLATES 0U U 2 BUMPERS 2. ALL DOORS TO HAVE WALL OR FLOOR MOUNTED BUMPER. PROVIDE REQUIRED TYPE FOR EACH SITUATION. 1 TYPE 1 3. ALL EXPOSED HARDWARE TO MATCH EXISTING FINISH. TYPE 1 2 4. MUST HAVE LOCK CORES THAT ARE THE BEST CORE SYSTEM AND KEYED 3 DOOR TYPES FRAME TYPES HARDWARE SETS TO THE LANDLORDS BUILDING MASTER SYSTEM. 4 WINDOW NOTES: —BUTT JOINT OUTSIDE CORNER TEMPERED GLASS —2" WOOD FRAME IN P2. 3'11" FINISHED FLOOR TO BOTTOM OF 3' - OF CLEAR FROM FRAME. WALL TYPE 3 2" SOLID SURFACE SILL OVER WOOD SUBSTRATE. a "T CLEAR TEMPERED GLASS DIVIDER SCREEN WITH POLISHED EDGES AND ALUMINUM U CHANNEL ATTACHMENT. 2X4 WOOD STUDS AT 16" O.C.. PLASTIC LAMINATE SKIN ON OUTSIDE AND FRP BOARD ON INSIDE. RESILIENT WALL BASE ON BOTH SIDES. P.►LlA��7»� TYPE "X" GYPSUM BOARD. DTH SIDES- FINISH TO 4" BOVE ACT CEILING GRID. $" 25 GA. METAL STUDS AT i" O.C.- WALL HEIGHT TO BE J BOTTOM CONCRETE DECK/ EAMS. LL WALL FULL DEPTH WITH DUND ATTENTION BLANKET. EX. $" TYPE "X" GYPSUM BOARD ON BOTH SIDES WITH CONTINUOUS ACOUSTICAL SEALANT BOTH SIDES. EX. 6" 20 GA. METAL STUD AT 16" O.C.- WALL HEIGHT IS TO BOTTOM OF EXISTING CONCRETE DECK/BEAM. EX. 5-1/2" BATT SOUND BATT ATTENTION BLANKET. 2- NEW $" TYPE "X" GYPSUM BOARD ON PROJECT SIDE WITH ATTACHMENT UTILIZING TYPE S SCREWS AND CONTINUOUS ACOUSTICAL SEALANT PROVIDE ADDITIONAL SEALANT AT THE TOP AND BOTTOM OF ALL DEMISING WALLS AND AT ALL PENETRATIONS THROUGH DEMISING WALLS TO BE SURE ANY ODORS FROM THIS PREMISES DOES NOT ENTER THE ADJACENT TENANTS PREMISES. WALL TYPE 5 UL DESIGN U408 (SIMILAR) 2 HOUR RATED ASSEMBLY WALL TYPE AND DOOR SCHEDULE MH/GL PLAN NORTH rApproved Date Project #100303 Sheet Date 1 /24/2017 Scale 1 /4"= 1 1-011 1 FINISH PLAN 3/16"-1'-0" FINISH LEGEND CODE DESCRIPTION MANUFACTURER STYLE/PATTERN COLOR SIZE NOTES CONTACT LVT1 LUXURY VINYL TILE PATCRAFT 1207V NORTH RIDGE 6 PC 02540 CABIN TIMBER 6' X 36' TILE -- scott,martin@patcraft,com LVT2 LUXURY VINYL TILE PATCRAFT 1700V STRATIFIED 00550 PEWTER 12' X 24' TILE -- scott,martin@patcraft,com EPF EPDXY PAINTED FLOOR - - TO MATCH RB1 - GRIT ADDED FOR SLIP RESISTANCE -- RB1 RESILIENT BASE J❑HNS❑NITE STANDARD WALL BASE 29 MOON ROCK WG 4'H -- jbatt@cdcdist.com PL1 PLASTIC LAMINATE WILS❑NART STUDIO TEAK 796OK-18 -- -- lukeb@lumbermens-inc,com PL2 PLASTIC LAMINATE WILS❑NART FROSTY WHITE 1573-60 -- -- lukeb@lumbermens-inc,com P1 PAINT SHERWIN-WILLIAMS -- SW7042 SH❑JI WHITE -- SATIN FINISH angie, julian@sherwin,com P2 PAINT SHERWIN WILLIAMS -- SW7047 P❑RP❑ISE -- SATIN FINISH angie, julian@sherwin,com P3 PAINT SHERWIN WILLIAMS -- SW6493 EBBTIDE -- SATIN FINISH angie, julian@sherwin,com RP1 RESIN PANEL LUMIC❑R LUMICLEAR COASTAL -- FINISH: MATTE/MATTE Amy@wmbakerco,com RP2 RESIN PANEL LUMIC❑R LUMICLEAR SEAGLASS -- FINISH: MATTE/MATTE Array@wmbakerco,com TG TEMPERED GLASS PANEL -- -- CLEAR -- 25' THICK POLISHED EDGES -- VWC VINYL WALL COVERING DL COUCH VERSA -WAVELENGTHS A115-000 SATIN -- INSTALL: RAILR❑AD mchandler@dlcouch,com FRP1 FRP WALL BOARD INPR❑ C❑RP❑RATI❑N -- CLAMSHELL 0154 4' X 8' SHEET SMOOTH SURFACE dharmon@inprocorp,com SS1 S❑LID SURFACE C❑RIAN -- GLACIER WHITE -- larry,brett@ovsco,com FAB FABRIC - -- -- -- -- -- ACT1 ACOUSTIC CEILING TILE ARMSTRONG CALLA WHITE 24'x 24'x 9/16' TEGULAR TILE SILHOUETTE XL 1/4' REVEAL GRID ANSmith@armstrongceilings,com ACT2 ACOUSTICAL CEILING TILE ARMSTRONG KITCHEN ZONE WHITE 24'x 24'x 1' TILE STANDARD ACOUSTICAL T- GRID ANSmith@armstrongceilings,com WWC WOOD WALL COVERING FASHI❑N ARCHITECTURAL DESIGNS FASHI❑N STACKED WOOD NATURALE FAD 0310 NANAVUT - - kguerrettaz@fashionadco,com GENERAL FINISH PLAN NOTES 1. CONTRACTOR TO REPAIR ALL EXISTING WALLS AND CEILINGS TO CONDITION SUITABLE TO ACCEPT NEW FINISHES. 2. ALL FLOORING TRANSITIONS TO OCCUR UNDER DOOR UNLESS INDICATED DIFFERENTLY ON PLANS. 3. CONTRACTOR TO SUBMIT FINISH SAMPLES IN TRIPLICATE TO LEHNER DESIGNS FOR APPROVAL PRIOR TO ORDERING. CONTRACTOR SHALL BE THE SOLE RESPONSIBLE PARTY IF ANY FINISHES ARE ORDERED INCORRECTLY IF PRODUCT WAS NOT APPROVED BY DESIGNER. 4. CONTRACTOR TO PROVIDE PROTECTION AS NEEDED FOR ANY EXISTING FINISHES TO REMAIN. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS AND JOB CONDITIONS. ANY DEVIATION FROM WHAT IS SHOW ON PLANS SHOULD BE BROUGHT TO DESIGNERS ATTENTION. 6. ALL DIMENSIONS SHOWN ARE TO FACE OF FINISH MATERIAL, UNLESS INDICATED OTHERWISE ON PLANS. 7. ALL INTERIOR DOORS AND DOOR FRAMES TO BE PAINTED IN A SEMI -GLOSS FINISH IN P2. 8. EXTERIOR EXISTING STEEL DOOR TO BE PAINTED IN SEMI -GLOSS iN P2 ON INSIDE ONLY. EXTERIOR TO MATCH BUILDING STANDARD. 9. WAINSCOTING TO BE A J"X4" (UNLESS OTHER DIMENSION SPECIFIED) WOOD WRAPPED ON 3 SIDES WITH PL1 AT VARYING LENGTHS. REFER TO ELEVATIONS (1,2,3,4/A3a). 10. THE SPACE BETWEEN WAINSCOTING RUNS AND RAISERS TO BE WALL PAINTED IN P2. REFER TO ELEVATIONS. (1,2,3,4/A3a). KEY FINISH PLAN NOTES 1. USE SCHLUTER TRANSITION FOR TRANSITION FROM EPDXY ONTO LVT. 2. EXISTING TILE FLOORING TO REMAIN. CLEAN AND REPAIR AS NEEDED. Project Name and Address MAIN STREET POKE 110 WEST MAIN STREET SUITE 106 CARMEL, IN 46032 Firm Name and Address Lehner Designs 1 290 Old Heritage Place Greenwood. Indiana 46 143 17.888.708e6 www.lehn,erdesigns.com THIS DRAWING SET IS PROVIDED IN CONFIDENCE AND SHALL BE USED ONLY AS INTENDED BY THE AGREEMENT WITH LEHNER DESIGNS. NO OTHER USE OR DUPLICATION MAYBE MADE WITHOUT PRIOR WRITTEN CONSENT OF LEHNER DESIGNS. ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLY RESERVED. No. Revision/Issue Date 1 Approved By 1 /24/2017 2 Scale 1 /4"= 1 1-011 3 4 FINISH PLAN AND SCHEDULE Designed By MH/GL PLAN NORTH Checked By GL Approved By Project #100303 Sheet Date 1 /24/2017 A5 Scale 1 /4"= 1 1-011 1 )_�� MENT PLAN 3/16"-1'-0" EQUIPMENT PLAN GENERAL NOTES: 1. ALL KITCHEN EQUIPMENT AND PLUMBING FIXTURES BY OWNER. CONTRACTOR TO COORDINATE ALL REQUIRED PLUMBING, POWER, HVAC, AND BLOCKING WITH OWNER AND PER MANUFACTURER CUT SHEET SPECIFICATIONS. 2. ALL LOOSE FURNITURE BY OWNER. EQUIPMENT PLAN LEGEND O18"D X 30"W ADJUSTABLE WIRE SHELVING O24"D X 60"W ADJUSTABLE WIRE SHELVING O24"W X12"D WALL SHELF O54"W X 324"D X 82 J"H REACH—IN REFRIGERATOR O88"W X 254"D 3—COMPARTMENT SINK O25" W X 21" D UTILITY SINK O38 J"W X 23 J"D 1—COMPARTMENT SINK O12"W X 16"D SPACE SAVER HAND SINK OI 12"W X 27"D COUNTERTOP COOKER & WARMER OJ 16"W X 27"D MICROWAVE OVEN O59"W X 27 4"D BUFFET DISPLAY TABLE WITH 12"D TRAY SLIDE O23 QT ELECTRIC RICE COOKER/WARMER O29"W X 324"D REACH—IN FREEZER O18"W X 18"D 1—COMPARTMENT BUDGET SINK O35J"W X 21i"D BUFFET DISPLAY TABLE WITH 12"D TRAY SLIDE OP 23.4"W X 30.7"D KEGERATOR O60"W X 30"D STAINLESS STEEL WRAPPED TABLE O10"W X 14"D 1—COMPARTMENT DROP—IN SINK OPOS SYSTEM O20.5"X45.125" AO SMITH ELECTRIC WATER HEATER DEN -40 O4'X4'X24"HOODMART EXHAUST HOOD CANOPY TYPE 1 TO BE INSTALLED AT A LATER DATE O28"X32"X84" AVANTCO GDC178GDC23 1 GLASS DOOR MERCHANDISING REFRIGERATOR 120V OOWNER PROVIDED 60" MENU MONITORS. Project Name and Address MAIN STREET POKE 110 WEST MAIN STREET SUITE 106 CARMEL, IN 46032 Firm Name and Address Lehner Designs 1 290 Old Heritage Place G reenwood. Indiana 461 3 317,8887086 THIS DRAWING SET IS PROVIDED IN CONFIDENCE AND SHALL BE USED ONLY AS INTENDED BY THE AGREEMENT WITH LEHNER DESIGNS. NO OTHER USE OR DUPLICATION MAYBE MADE WITHOUT PRIOR WRITTEN CONSENT OF LEHNER DESIGNS. ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLY RESERVED. EQUIPMENT PLAN AND SCHEDULE Designed By MH/GL Revision/Issue Date 1 Approved By 1 /24/2017 F4No. 2 Scale 1 /4"= 1 1-011 3 EQUIPMENT PLAN AND SCHEDULE Designed By MH/GL PLAN NORTH Checked By GL Approved By Project #100303 Sheet Date 1 /24/2017 A6 Scale 1 /4"= 1 1-011 PANEL/SPACE FEEDER LCL INPUT FACTOR VA CKT. CATALOG# BKR BKR signage, general lighting, POS, unit heater, etc. 5861 1.25 7326 show -window or entry lighting at show -window SIZE A B C 1.25 0 * track lighting 20 75.00 1500 * track lighting show -window 60/2 4992 75.00 0 " a.c. equipment rtu, ahu, cu, etc. - 208 volt, 3 ph 3 360.26 0 ** a.c. equipment rtu, ahu, cu, etc. - 208 volt, 1 ph 4 208.00 0 Misc. HVAC - coolers, freezers, MUA, etc. 24384 1 24384 6 FURNACES BUFFET DISPLAY TABLE 7 1023 Sub Total 4992 33210 120V COOKER/WARMER 9 1500 NON LCL 30/3 2138 10 HH4-4501 RICE COOKER 11 96 - water heater, sensormatic, traffic counter, misc., etc. 11499 1 11499 "* receptacles 4020 120V 4020 *** show window lighting requirement in feeder only) F --B EXISTING RECEPTICALS 0 *** Kitchen equipment 100% - exhaust hoods, etc. 200 1 200 *** Kitchen equipment 90% - ovens, mist. equipment, etc. 8174 0.65 5313 EXISTING RELOCATED LED DOWNLIGHT 180 T_ 18 EX. BATHROOM GFI SPARE Sub Total - 21032 1128 20 REACH IN REFRIGERATOR GEN RECEPTS 21 TOTALI RECESSED 54242 208 volt - total amperage e auls 1 150.6 " Track lighting calculated per 2011 NEC ** MCA used includes 125% of largest motor per 2011 NEC *** Receptacles calculated per 2011 NEC Article 220.14(1) **** Show -window lighting calculated per 2011 NEC Article 220.14(G) ***** Kitchen equipment calculated per NEC Article 220-56 4 HALLWAY SWITCH TO 0 0 BE THREE-WAY KITCHEN HALLWAY LIGHTING LIGHTING 1 -2-GANG LIGHT SWITCH +46" AFF COVERPLATE PROVIDE PERMANENT, TYPED LABELS AS SHOWN. SWITCH BANK DETAIL #2 NOT TO SCALE 34 36 40 0 0 0 42 0 LDINNIIING NG LDINNIIING LNG I I DINNING 11 LIGHTING NG NG 1 `4 -GANG LIGHT SWITCH +46" AFF COVERPLATE PROVIDE PERMANENT, TYPED LABELS AS SHOWN. SWITCH BANK DETAIL #1 NOT TO SCALE 1st 10 kva @ 100%, All other @ 50% 200 VA per LF of show -window minus actual lig PANEL DIRECTORY PANEL EX. PANEL TO REMAIN 120/208 VOLT 3 PHASE 4 WIRE SYM LUGS EX. 200 AMP MAIN BREAKER EX. 200 AMP DESCRIPTION CKT. CATALOG# BKR BKR CKT. REMARKS USE NO. LOAD SIZE A B C SIZE LOAD NO. USE MENU MONITORS 1 1500 20/1 60/2 4992 2 FURNACES POS SYSTEM 3 500 PENDANT 4992 4 Al BUFFET DISPLAY TABLE 5 759 20OW 60/2 4992 6 FURNACES BUFFET DISPLAY TABLE 7 1023 V.I.F. 4992 8 120V COOKER/WARMER 9 1500 B 30/3 2138 10 HH4-4501 RICE COOKER 11 96 - 21,388 12 EX AHU-1 RICE COOKER 13 96 120V 2138 14 F --B EXISTING RECEPTICALS 15 720 MFG -H-18112 20/1 1500 16 EX. HANDRYER FUT REFRIGERATOR 17 1128 EXISTING RELOCATED LED DOWNLIGHT 180 T_ 18 EX. BATHROOM GFI SPARE 19 - pQ 1128 20 REACH IN REFRIGERATOR GEN RECEPTS 21 1080 RECESSED 30/3 3333 22 EX/X REACH -IN FREEZER 23 1032 V.I.F. 3333 24 WATER HEATER EX WATER HEATER 25 1500 V.I.F. 3333 26 120V GEN RECEPTS 27 540 X 30/2 3100 28 MICROWAVE BEVERAGE DISPLAY 29 912 MATCH EXISTING, FIELD VERIFY MAKE AND MODEL 3100 30 EXIT LIGHT WITH 90MIN BATTERY BACKUP AND DUAL HEAD EMERGENCY LIGHTING PACK FUT. EXHAUST HOOD 31 200 120V 20/1 216 32 KEGERATOR SPARE 33 - N1L 770 34 GEN LIGHTS SIGN 35 1000 541 36 GEN LIGHTS SPARE 37 - 30 38 EM LIGHTS GEN LIGHTS 39 278 906 40 GEN LIGHTS GEN LIGHTS 41 600 736 42 GEN LIGHTS PHASE A: 21763 WATTS PHASE B: 21357 WATTS PHASE C: 20763 WATTS TOTAL: 63268 WATTS BALANCE: 2.78 % LIGHT FIXTURE SCHEDULE SYM MARK DESCRIPTION MFG CATALOG# LAMP TYPE VOLTAGE MOUNTING REMARKS n n n n EXR/TL EXISTING RELOCATED TRACK LIGHT TRACK QTY: 5 HEAD QTY: 20 ELITE TRACK: ET4-WH HEADS: ET402WH 50W MR16 LED 120V TRACK 1 9.4 OA I PENDANT LIGHT HI -LITE H-15216 30W LED 120V PENDANT 1 O Al PENDANT LIGHT HI -LITE H-15212 20OW 120V PENDANT 208 1 EXR/A2 EXISTING RELOCATED 2X4 V.I.F. V.I.F. V.I.F. 120V RECESSED NL DENOTES NIGHT LIGHT O B LED DOWNLIGHT ELITE HH4-4501 27W LED 120V RECESSED - O C LED DOWNLIGHT ELITE HH6-6501 55W LED 120V RECESSED - F --B D WALL MOUNT ACCENT LIGHT HI -LITE MFG -H-18112 38W LED 120V WALL FURNISH AND INSTALL WITH HL -A MOUNTING ARM OQ EXR/E EXISTING RELOCATED LED DOWNLIGHT ELITE RL625 14W LED 120V RECESSED NL DENOTES NIGHT LIGHT pQ EX/E EXISTING LED DOWNLIGHT ELITE RL625 14W LED 120V RECESSED NL DENOTES NIGHT LIGHT ® EX/X EXISTING EXIT LIGHT WITH BATTERY BACKUP V.I.F. V.I.F. V.I.F. 120V CEILING POS ® EXR/X EXISTING RELOCATED EXIT LIGHT WITH BATTERY BACKUP V.I.F. V.I.F. V.I.F. 120V CEILING/ WALL 27.7 ® X EXIT LIGHT WITH BATTERY BACKUP V.I.F. V.I.F. V.I.F. 120V CEILING/ WALL MATCH EXISTING, FIELD VERIFY MAKE AND MODEL 7.6 Y EXIT LIGHT WITH 90MIN BATTERY BACKUP AND DUAL HEAD EMERGENCY LIGHTING PACK NAVILITE NXPCL INCLUDED LED 120V CEILING/ / Y1 DUAL HEAD EMERGENCY LIGHTING PACK WITH 90MIN BATTERY BACKUP NAVILITE N1L INCLUDED LED 120V CEILING/ WALL RISER DIAGRAM NOTES 1. CONTRACTOR SHALL OBTAIN AVAILABLE FAULT CURRENT RATING AND PROVIDE PROTECTION FOR MAIN CIRCUIT BREAKER AND ALL BRANCH DEVICES AS REQUIRED. 2. CONTRACTOR TO MAINTAIN ALL REQUIRED CLEARENCES PER ARTICLE 110-26 NEC ELECTRIC RISER DIAGRAM NOT TO SCALE KEYNOTES 1. EXISTING 120/208 VOLT, 3 PHASE, 4 WIRE, 200 AMP SERVICE TO SPACE TO REMAIN. (4 -X3/0 -2"C) 2. EXISTING 120/208 VOLT, 3 PHASE, 4 WIRE, 200 AMP PANEL WITH 200 AMP MAIN BREAKER TO REMAIN. 3. EXISTING AC -1 ON THE ROOF TO REMAIN. 4. EXISTING DISCONNECT SWITCH ON THE ROOF TO REMAIN. 5. EXISTING CONDUIT AND WIRE TO REMAIN. FIELD VERIFY EXACT SIZE. EQUIPMENT SCHEDULE TAG MANUFACTURER MODEL CW HW DRAIN VOLTAGE PHASE AMP DESCRIPTION D AVANTCO 178CFD2RR - - - 120 1 9.4 REACH IN REFRIGERATOR I APW WYOTT W -43V - - - 120 1 12.5 COUNTERTOP COOKER/WARMER J TURBOCHEF SOTA TOUCH i 1 -9500-400 _ _ 208 1 30 MICROWAVE K TURBO AIR JBT-60 - - - 115 1 8.9 BUFFET TABLE L TOWN 56919 - - - 115 1 0.83 23QT RICE COOKER M AVANTCO 178CFDlFF - - - 120 1 8.6 REACH IN FREEZER 0 TURBO AIR JBT-36 - - - 115 1 6.6 BUFFET TABLE P KEGCO XCK-1 - - - 115 1 1.8 KEGERATOR S CLOVER CLOVER STATION - - - 120 1 - POS T AO SMITH DEN -40 3/4" 3/4" 3/4" ID 208 3 27.7 WATER HEATER V AVANTCO 178GDC23 - - - 120 1 7.6 BEVERAGE DISPLAY COOLER FLOOR PLAN - LIGHTING WORK SCALE: 3/16" = V-0" KEY NOTES 1. EXISTING SWITCH TO BE REWIRED TO LIGHTING IN AREA. 2. FURNISH AND INSTALL NEW SWITCH BANK FOR CONTROL OF DINING AREA LIGHTS, SEE DETAIL #1 THIS SHEET. 3. FURNISH AND INSTALL NEW SWITCH BANK FOR CONTROL OF KITCHEN AND HALLWAY LIGHTS, SEE DETAIL #2 THIS SHEET. 4. EXISTING EXHAUST FAN TO REMAIN, RECONNECT AS REQUIRED. FLOOR PLAN - MISCELLANEOUS ELECTRIC WORK SCALE: 3/16" = V-0" KEY NOTES 1. PROVIDE RECEPTACLE AT CEILING FOR USE WITH 60" SUSPENDED MONITOR, VERIFY EXACT LOCATION WITH PROJECT MANAGER AND COORDINATE LOCATION WITH TV MOUNTING SYSTEM. 2. EXISTING PANEL 120/208 VOLT, 3 PHASE, 4 WIRE, 200 AMP PANEL WITH 200 AMP MAIN BREAKER TO REMAIN. 3. TAMPER RESISTANT COMBINATION USB RECEPTACLE. COOPER WIRING DEVICES MODEL: TR7740BK-BOX. 4. INSTALL USB RECEPTACLES 6" ABOVE TABLE TOP, COORDINATE EXACT MOUNTING HEIGHT WITH PROJECT MANAGER PRIOR TO ROUGH -IN. 5. EXISTING AHU-1 IN CEILING TO REMAIN 6. EXISTING AC -1 ON ROOF TO REMAIN. 7. FURNISH AND INSTALL GFI FLOOR BOX FOR DUPLEX RECEPTACLE, PROVIDE TRENCH TO WALL, CUT AND PATCH FLOOR AS REQUIRED. 8. FURNISH AND INSTALL JUNCTION BOX FOR SIGN, COORDINATE EXACT LOCATION AND HEIGHT WITH PROJECT COORDINATOR. Project Name and Address MAIN STREET POKE 110 WEST MAIN STREET CARMEL, IN 46032 Firm Name and Address Lehner Desips 1290, Old Heritage Place Greenwood, Indiana 46143 317.8897086 waw+wv.�ehnerdesigns.com THIS DRAWING SET IS PROVIDED IN CONFIDENCE AND SHALL BE USED ONLYAS INTENDED BY THE AGREEMENT WITH LEHNER DESIGNS. NO OTHER USE OR DUPLICATION MAYBE MADE WITHOUT PRIOR WRITTEN CONSENT OF LEHNER DESIGNS. ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLY RESERVED. P f. 1533 EAST NORTHFIELD DRIVE SUITE 400 W SPEGPWWNCfRMECOM FLOOR PLAN ELECTRICAL WORK Revision/Issue Date 1 F4No. 2 Scale 3/16"=1'-0" 3 1/24/2017 FLOOR PLAN ELECTRICAL WORK Project PLAN NORTH C E Project Sheet #100303 Date 1 /20/2017 Scale 3/16"=1'-0" MECHANICAL WORK NOTES - GENERAL 1. MECHANICAL WORK SHALL BE COMPLETE IN EVERY DETAIL AND ALL MISCELLANEOUS ITEMS OF MATERIAL AND LABOR NECESSARY TO COMPLETE THE WORK DESCRIBED, SHOWN OR REASONABLY IMPLIED ON DRAWINGS OR SPECIFICATIONS SHALL BE INCLUDED IN THE CONTRACT. CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO THE WORK WHERE REQUESTED BY THE TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 2. MECHANICAL CONTRACTOR SHALL VISIT THE SITE AND VIEW ALL EXISTING CONDITIONS BEFORE SUBMITTING A PROPOSAL FOR THE WORK AS DESCRIBED AND SHOWN. NO EXTRAS WILL BE ENTERTAINED FOR FAILURE TO MAKE THIS VISIT. 3. MECHANICAL CONTRACTOR SHALL ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 4. CONFORM TO GENERAL CONTRACTOR'S SCHEDULE AND INSTRUCTIONS THROUGHOUT THE DURATION OF THE PROJECT AS REQUIRED TO COMPLY IN EVERY WAY NECESSARY. 5. CONTRACTOR SHALL NOTIFY THE ARCHITECT AND/OR ENGINEER OF ERRORS, OMMISSIONS OR DISCREPENCIES BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK, OR, FAILING SUCH NOTICE, SHALL BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, ARCHITECT OR ENGINEER. 6. ORDER EQUIPMENT ON A TIMELY BASIS (WITHIN 5 DAYS OF RECEIPT OF CONTRACT) TO MAINTAIN CONSTRUCTION SCHEDULE. 7. SUBMIT FIVE (5) COPIES OF SHOP DRAWINGS OF ALL EQUIPMENT FOR REVIEW BY THE ENGINEER/ARCHITECT. ONE (1) COPIES WILL BE RETAINED FOR RECORD. ONLY FURNISH SYSTEMS, EQUIPMENT AND MATERIAL IN COMPLIANCE WITH APPROVED SHOP DRAWINGS. 8. WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS, WARRANTEE FOR ALL EQUIPMENT AND ONE YEAR GUARANTEE OF ALL WORKMANSHIP, COMMENCING ON DATE OF ACCEPTANCE BY THE TENANT. 9. WORK SHALL ALSO INCLUDE FULL ONE (1) YEAR MAINTENANCE, PARTS AND SERVICE CONTRACT FOR ALL EQUIPMENT FURNISHED UNDER THE CONTRACT. 10. ON ALL AIR CONDITIONING EQUIPMENT WHICH INCLUDES COMPRESSORS (ROOFTOP, SPLIT SYSTEMS, ETC.), INCLUDE AN EXTENDED FOUR (4) YEAR WARRANTY FOR THE COMPRESSOR. 11. VOLUME DAMPERS, SPLITTERS AND DEFLECTORS SHALL BE INSTALLED IN ALL DUCTS TO PERMIT ACCURATE BALANCING OF SYSTEM. THE DAMPERS, SPLITTERS AND DEFLECTORS SHALL BE ADJUSTED TO SATISFY THE HVAC REQUIREMENTS OF THE CONDITIONED SPACE AND LOCKED IN PLACE AS REQUIRED. 12. WORK SHALL ALSO INCLUDE TESTING AND BALANCING OF A.C. SYSTEM BY A CERTIFIED BALANCING CONTRACTOR. CONTRACTOR SHALL SUBMIT COPIES OF TEST AND BALANCE REPORTS SHOWING DETAILED RESULTS OF WORK, INCLUDING, BUT NOT LIMITED TO THE FOLLOWING: FLOW READINGS, STATIC PRESSURES, TEMPERATURE READINGS, MOTOR AMPERAGE, BALANCING OF AIR QUANTITIES TO PLAN REQUIREMENTS, ETC. AS REQUIRED. MAKE ALL ADJUSTMENTS AS REQUIRED TO PROVIDE DESIGN AIR FLOW. 13. FURNISH ALL EQUIPMENT MANUALS AND WARRANTIES TO TENANT AT THE COMPLETION OF THE PROJECT. 14. WHERE APPLICABLE, FURNISH AND INSTALL VIBRATION ISOLATION AS REQUIRED TO REDUCE, LIMIT OR REMOVE ALL VIBRATIONS FOR ALL MOVING EQUIPMENT. VIBRATION ISOLATION SHALL BE IN ACCORDANCE WITH ASHRAE RECOMMENDATIONS. 15. PROVIDE ENGRAVED BAKELITE NAMEPLATES FOR ALL MECHANICAL EQUIPMENT INCLUDING TENANT'S NAME AND SPACE NUMBER. LETTERS SHALL BE 2" HIGH OR AS REQUIRED BY THE LANDLORD. 16. ALL FABRICATED COMPONENTS (CONTRACTOR OR MANUFACTURER) OF THE OUTSIDE AIR, SUPPLY AIR, RETURN AIR AND EXHAUST AIR SYSTEMS SHALL BE CONSTRUCTED AND INSTALLED AIR TIGHT. THE INSTALLED SYSTEMS SHALL BE PRESSURE TESTED AS REQUIRED. 17. NOT USED. 18. FURNISH TWO (2) COPIES OF AS BUILT DRAWINGS OF THE A.C. SYSTEM TO THE OWNER FOR REVIEW AND APPROVAL, OR SUBMIT A LETTER TO THE OWNER CONFIRMING THAT THE SYSTEM WAS INSTALLED AS PER PLANS AND SPECIFICATIONS. 19. ALL WORK AND EQUIPMENT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING PROJECT OVER TO THE OWNER. 20. SEAL ALL PENETRATIONS THROUGH WALLS, CEILINGS, FLOORS, ETC. SO THAT THEY ARE AIR, WATER AND FIRE TIGHT. 21. FURNISH AND INSTALL ACCESS PANELS FOR ALL CONCEALED EQUIPMENT, FIRE DAMPERS, PIPING VALVES, CLEANOUTS, ETC. ACCESS PANELS SHALL BE OF SUFFICIENT SIZE TO PROVIDE ADEQUATE WORKING CLEARANCE AND ACCESS. 22. FURNISH ALL MATERIAL AND EQUIPMENT AS SPECIFIED, EXCEPT WHERE SPECIFIC APPROVAL FOR SUBSTITUTION IS GIVEN BY THE TENANT. 23. PROPOSAL SHALL BE BASED ON SPECIFIED MATERIAL AND EQUIPMENT. IN ORDER TO PROMOTE COMPETITION, HOWEVER, BIDDERS ARE ENCOURAGED TO SUBMIT ALTERNATE PROPOSALS ON ANY ALTERNATE MATERIALS AND/OR EQUIPMENT THEY WISH TO PROPOSE, INCLUDING ANY PRICE CHANGES EFFECTED BY ACCEPTANCE OF ALTERNATES. 24. COST OF ANY CHANGES REQUIRED BY OTHER TRADES DUE TO SUBSTITUTION OF ALTERNATE EQUIPMENT SHALL BE INCLUDED IN THE ALTERNATE PROPOSAL. 25. ALTERNATE PROPOSALS WILL BE ACCEPTED OR REJECTED BEFORE ISSUANCE OF CONTRACTS. NO CHANGES WILL BE ALLOWED AFTER THE CONTRACT IS SIGNED. ANY UNAUTHORIZED CHANGES TO THE DESIGN AND LAYOUT MAY BE REQUIRED TO BE REMOVED AT CONTRACTOR'S EXPENSE IF DEEMED NECESSARY BY THE ARCHITECT, ENGINEER OR OWNER'S REPRESENTATIVE. 26. VERIFY LOCAL CONDITIONS AT SITE. 27. COMPLY WITH ALL APPLICABLE CODES. 28. SECURE AND PAY FOR ALL REQUIRED PERMITS. 29. SEE REFLECTED CEILING PLAN FOR EXACT LOCATION OF CEILING GRID, LIGHT FIXTURES, ETC. 30. ALL INSULATION MATERIALS, INCLUDING, BUT NOT LIMITED TOO DUCT INSULATION AND PIPING INSULATION SHALL HAVE A FLAME SPREAD RATING OF 25 OR LESS (ON THE FLAME SPREAD TEST SCALE) AND SMOKE DEVELOPMENT OF 50 OR LESS (ON THE SMOKE TEST SCALE) OR AS DEFINED BY NFPA 255 STANDARD METHOD OF TESTING OF SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, LOCAL CODES AND LOCAL AUTHORITIES HAVING JURISDICTION. 31. DIELECTRIC UNIONS SHALL BE USED TO CONNECT DISSIMILIAR METALS OR METAL PIPING SHALL HAVE METAL CONNECTIONS ON EACH END THREADED TO MATCH THE ADJACENT PIPING. METAL COMPONENTS SHALL BE SEPARATED BY A NYLON INSULATOR TO PREVENT CURRENT FLOW BETWEEN DISSIMILAR METALS. UNIONS SHALL BE SUITABLE FOR THE SYSTEM OPERATING PRESSURES AND TEMPERATURE WELD TYPE: ASTM A-234. MECHANICAL WORK NOTES -AIR FILTERS 1. ON THE DAY OF STORE CONSTRUCTION COMPLETION/TURNOVER, THE AIR CONDITIONING EQUIPMENT FILTERS, IF ANY, (WHETHER NEW CONSTRUCTION OR EXISTING) SHALL BE REPLACED WITH NEW FILTERS. 1. PULL OUTER INSULATION JACKET BACK AND SLIDE INNER LINE OVER SHEETMETAL COLLAR SHEETMETAL BOOT COLLAR SUPPLY DIFF RETURN AIR ITER INSULATION JACKET VER DUCT LINER 2.. TAPE INNER -LINER TO SHEETMETAL COLLAR WITH SILVER DUCT TAPE. DUCT TAPE SHOULD BE WRAPPED AROUND SHEETMETAL. COLLAR TWO FULL TURNS SHEETMETAL BOOT COLLAR SUPPLY DIFFI RETURN AIR LITER INSULATION JACKET NER DUCT LINER UCT TAPE TEMPERATURE CONTROL NOTES 1. FURNISH AND INSTALL A NEW THERMOSTATS FOR CONTROL A.C. UNITS. HONEYWELL, MODEL #TB710OA1000/U. 2. INSTALL IN THE LOCATION SHOWN. 3. VERIFY THE NUMBER OF CONTROL WIRES REQUIRED FOR A COMPLETE INSTALLATION. 4. INSTALLATION OF THE THERMOSTATS SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS. 5. WITH SYSTEM ON "DAY" CYCLE: A. SUPPLY FAN RUNS CONTINUOUSLY. B. THERMOSTAT SHALL ENERGIZE COOLING OR HEATING CYCLES IN THE A.C. UNIT AS REQUIRED. 6. WITH SYSTEM ON "NIGHT" CYCLE: A. SUPPLY FAN OFF. B. COOLING CYCLE INOPERATIVE. C. ON A CALL FOR HEATING FROM THE THERMOSTAT, FAN SHALL START AND HEATING CYCLE SHALL BE ENERGIZED; BOTH SHALL CONTINUE TO OPERATE UNTIL THE THERMOSTAT IS SATISFIED. MECHANICAL GENERAL NOTES 1. THE BUILDING IS EXISTING AND HAS PREVIOUSLY BEEN OCCUPIED. 2. RELOCATE EXISTING AND INSTALL NEW DIFFUSERS AND REGISTERS AS SHOWN AND SPECIFIED. FURNISH AND INSTALL VOLUME DAMPERS AT ALL NEW BRANCH TAKEOFFS. 3. TEMPERATURE CONTROLS, INCLUDING WIRING, SHALL BE PART OF THE MECHANICAL CONTRACT. 4. FIBERGLASS DUCTWORK IS NOT PERMITTED. 5. FLEXIBLE DUCTWORK MAY BE USED FOR VERTICAL DIFFUSER CONNECTIONS ONLY AND SHALL BE LIMITED IN LENGTH TO 5'-0" MAX. 6. ALL DUCTWORK SHALL CONFORM TO THE LATEST EDITION OF SMACNA STANDARDS AND RECOMMENDATIONS. 7. DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSION AND SHALL BE ADJUSTED IF REQUIRED TO ACCOUNT FOR METHOD OF INSULATION. 8. FIRE STOP ALL PENETRATIONS THROUGH FIRE RATED PARTITIONS (IF REQUIRED) IN STRICT ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES. VERIFY EXACT METHOD OF FIRE AND MOISTURE CONTROL WITH LANDLORD AND/OR ARCHITECT. A.C. UNIT REFURBISHMENT NOTES 1. BASE BID SHALL INCLUDE A DETAILED FIELD INSPECTION OF THE EXISTING A.C. UNITS TO DETERMINE THEIR CONDITION AND COSTS TO PERFORM MAINTENANCE SERVICE ON EXISTING SYSTEM AS REQUIRED TO GUARANTEE PROPER OPERATION, CONSISTING OF, BUT NOT LIMITED TO, THE FOLLOWING: A. CHECK AND ADJUST BELTS. REPLACE IF REQUIRED. B. CHECK FAN FOR PROPER OPERATION. REPLACE BEARINGS IF REQUIRED. C. CHECK REFRIGERANT PIPING SYSTEM FOR LEAKS. REPAIR AS REQUIRED. D. CHECK REFRIGERANT CHARGE. ADD REFRIGERANT AS REQUIRED. E. REPLACE REFRIGERANT FILTER/DRIER IF EXISTING. F. CHECK REFRIGERANT LINE PRESSURES. IF ABOVE RATED LIMITS, CLEAN AND/OR REPLACE PIPING AS REQUIRED. G. CHECK COMPRESSOR AND FAN MOTOR AMPERAGE. IF ABOVE RATED LIMITS, REPLACE AS REQUIRED. H. CLEAN COIL SURFACE IF REQUIRED. I. REPLACE FILTERS. J. CHECK AND ADJUST CONTROLS. K. REPAIR ANY RUSTED AREAS ON UNIT CASINGS. REPAINT AS REQUIRED. L. CHECK HEAT EXCHANGER FOR PROPER OPERATION AND/OR DETERIORATION. REPLACE AS REQUIRED. M. CHECK AND REPLACE FAN PROVING SWITCH TO ENSURE PROPER OPERATION OF HEATING CYCLE, ETC. N. ADJUST AS REQUIRED TO DELIVER AIR QUANTITY SHOWN OR CALLED FOR. 2. SUBMIT AN ALTERNATE PROPOSAL ACCOMPANYING BID TO REPLACE ALL EXISTING EQUIPMENT, WHICH WILL BE CONSIDERED BY THE TENANT IF THE EQUIPMENT IS DETERMINED TO BE IN NEED OF REPLACEMENT AFTER THE INITIAL INSPECTION AT THE JOB SITE. ALTERNATE PROPOSAL SHALL BE COMPLETE, INCLUDING LABOR, RIGGING COSTS (IF ANY), ETC. SYMBOLS AND ABBREVIATIONS CFM CUBIC FEET PER MINUTE CD CEILING DIFFUSER RAR RETURN AIR REGISTER S.A. SUPPLY AIR R.A. RETURN AIR O.A. OUTDOOR AIR OT THERMOSTAT HVAC UNIT SCHEDULE MARK SERVICE TYPE MODULE/FACE SIZE BACKPAN MFGR. & MOD. NO. MFR. AND NOMINAL SA OSA COMMENTS COOLING CAPACITY SQUARE HEATING CAPACITY 18" X 18" ELECTRICAL 3 - LAY -IN APPROX. 2,4,7 SENSIBLE TOTAL EER/ INPUT OUTPUT PH. EVAP. FAN COMPRESSORS CONDENSER FAN MIN. MARK MODEL NO. TONS CFM CFM OPER. REMARKS VOLT FLA QTY. RLA LRA QTY. HP FLA AIMPSIT TITUS 50F 3 - LAY -IN - 10 (MBH) (MBH) SEER (MBH) (MBH) BS. EX. AHU-1 CARRIER FB4CNF048 40 1600 * * * * * * 208 1 * - - - - - - * * 1002 03 EX. AC -1 BRYANT 113APA048-E 4.0 - - , * * - - 208 3 - 1 13.1 83.1 1 1/4 1/4 17.5 * 1002 03 1N LOW AMBIENT CONTROL TO 0' O RATED @ 80' EDB, 67' EWB, 95' AMBIENT O PROVIDE 5 YEAR COMP. WARRANTY O STANDARD EFFICIENCY MODEL COMPLETE WITH ECONOMIZER CYCLE AND ALL FACTORY SAFETY AND OPERATING CONTROLS O PROVIDE 2" THICK THROWAWAY FILTERS 07 TRANE, YORK AND LENNOX ARE ACCEPTABLE ALTERNATES. CONTRACTOR SHALL SUBMIT ALTERNATE FOR APPROVAL. SEE NOTES #23-25 UNDER MECHANICAL WORK NOTES - GENERAL FOR ALTERNATE SUBMITTAL INSTRUCTIONS. OFURNISH AND INSTALL MANUFACTURER CURB. *EXISTING INFORMATION UNKNOWN. FIELD VERIFY. AIR DEVICE SCHEDULE MARK SERVICE TYPE MODULE/FACE SIZE BACKPAN MFGR. & MOD. NO. BORDER TYPE PATTERN NOTES COLOR COMMENTS A SUPPLY SQUARE 24" X 24" 18" X 18" TITUS TDCA 3 - LAY -IN 4 -WAY 2,4,7 WHITE BORDER CORE AREA B RETURN SQUARE 24" X 24" SEE PLAN TITUS 50F 3 - LAY -IN - 10 WHITE NOTES: 1. PROVIDE WITH AG -35 -AA OPPOSED BLADE VOLUME DAMPER (RECT. 272RS & 23RL) 2. PROVIDE WITH MODEL EG EQUALIZING GRID 3. PROVIDE WITH MODEL AG -95 OPPOSED BLADE VOLUME DAMPER (SQUARE) 4. PROVIDE WITH MODEL AG -75 OPPOSED BLADE VOLUME DAMPER (ROUND) 5. PROVIDE WITH TRM PLASTER FRAME 6. PROVIDE WITH RUSKIN MODEL CFD FIRE DAMPER 7. LIMIT FLEXIBLE DUCT CONNECTION TO 5'-0" MAXIMUM 8. PROVIDE WITH TITUS MODEL MPI37 INSULATED PLENUM (DO NOT SUPPLY FOR BLANK SECTIONS) 9. PROVIDE PREFAB PLASTER FRAME FOR MOUNTING 10. PROVIDE WITH MODEL AG -15 -AA VOLUME DAMPER (RETURN RECT. 50F) 3. PULL OUTER INSULATION HACKET OVER SHEETMETAL COLLAR AND PLACE A METAL DRAW BAND OVER THE OUTER INSULATED JACKET BELOW THE SHEETMETAL COLLAR BEAD SHEETMETAL BOOT COLLAR SUPPLY DIFFU`. RETURN AIR GI LITER INSULATION JACKET NER DUCT LINER dETAL DRAW BAND 4. CUT EXCESS METAL DRAW BAND OFF AND WRAP METAL DRAW BAND WITH SILVER DUCT TAPE. SHEETMETAL BOOT COLLAR SUPPLY DIFFU RETURN AIR G FLEX DUCT CONNECTION TO DUFFUSERS, GRILLES AND SHEETMETAL PLENUM COLLARS NOT TO SCALE MUTER INSULATION JACKET INER DUCT LINER DUCT TAPE WRAPPED OVER METAL DRAW BAND DIFFUSER A 400 6"0 AIR QUANTITY (CFM) FLEXIBLE DUCT CONNECTION SIZE REGISTER TYPE G 1200 16X16 AIR QUANTITY (CFM) CORE AREA ROOF DECKING GROMMET GALVANIZED CARBON' --3 1/2" WIDE NYLON STRAPS STEEL HANGER WIRE NAILED TO BOTTOM OF JOIST (FURNISHED BY HVAC INSTALLING FLEXIBLE CONTRACTOR)0 DUCTWORK FLEXIBLE DUCT SUPPORT DETAIL NOT TO SCALE FLOOR PLAN - MECHANICAL WORK SCALE: 3/16" = V-0" KEYNOTES 1. EXISTING DUCTWORK TO REMAIN SHOWN HATCHED, EXACT LOCATION AND LAYOUT MAY VARY, VERIFY EXACT LOCATION AND LAYOUT IN FIELD. 2. EXISTING DIFFUSER TO REMAIN. 3. CONNECT NEW DIFFUSER TO EXISTING SUPPLY DUCT AND ADJUST EXISTING DAMPERS AS REQUIRED. 4. CONNECT NEW DUCTWORK TO EXISTING DUCTWORK ABOVE CEILING AS REQUIRED. PATCH AND REPAIR EXISTING CONNECTIONS IF REQUIRED. 5. FURNISH AND INSTALL NEW VOLUME DAMPERS AT ALL DUCTWORK TAKE -OFFS. 6. CUT AND PATCH MAIN DUCTWORK TRUNK AS REQUIRED TO TERMINATE AT THIS LOCATION. 7. EXISTING AHU-1 ABOVE CEILING TO REMAIN. 8. EXISTING AC -1 ON ROOF TO REMAIN. LIQUID AND SUCTION CONNECTIONS TO EX. AHU-1 TO REMAIN. 9. EXISTING EXHAUST FAN TO REMAIN. Project Name and Address MAIN STREET POKE 110 WEST MAIN STREET CARMEL, IN 46032 Firm Name and Address Lehner Deem 1290, Old Heritage Place Greenwood. Indicaraa 46143 312'.8818,. 086 wrwrw.lehnerd�esigiis.com THIS DRAWING SET IS PROVIDED IN CONFIDENCE AND SHALL BE USED ONLYAS INTENDED BY THE AGREEMENT WITH LEHNER DESIGNS. NO OTHER USE OR DUPLICATION MAYBE MADE WITHOUT PRIOR WRITTEN CONSENT OF LEHNER DESIGNS. ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLY RESERVED. V"41 wxA .M G,, 1533 EAST NORTHFIELD DRIVE SUITE 400 BROWNSBURG IN 46112 WWW.SPENCfRMEP.COM No.3 PLAN NORTH (I Date 1 FRevision/Issue 2 Scale 3/16"=1'-0" 4 1/24/2017 ER� ® VVu V ® ®� o. 10403982 ®� = STATE OF ®®®SFS ' . �ND I A VA \�®NN ®mmo�e®o J FLOOR PLAN MECHANICAL WORK Project PLAN NORTH (I C EApproved Project Sheet #100303 Date 1 /20/2017 Scale 3/16"=1'-0" GREASE INTERCEPTOR CALCULATION 3 -COMPARTMENT SINK (A) -16" X 20" X 12" X 3 = 11,520 CUBIC INCHES TOTAL -11,520 CUBIC INCHES CONTENTS IN GALLONS: 11,520 CUBIC INCHES/231 • = 49.8 GALLONS ACTUAL DRAINAGE LOAD: 49.8 X 0.75 = 37.40 GALLONS (25% DISPLACED BY DISHES) 2 MINUTE DRAINAGE RATE: 37.40/2 = 18.7 GALLONS ;1 GALLON = 231 CUBIC INCHES GENERAL NOTES A. DESIGN DRAWINGS ARE SCHEMATIC. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. B. CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. C. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WTIH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING, THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. L� BRASS CLEANOUT PLUG - WITH COUNTERSUNK HEAD C.I. WASTE PIPEX1/8 C.I. BEND LENGTH TO SUIT FIXTURE UNIT CALCULATION TAG PLUMBING QUANTITY SAN. F.U. SAN. F.U. WATER F.U. WATER F.U. FIXTURES EACH TOTAL EACH TOTAL EX. WATER CLOSET 1 4.0 4.0 5.0 5.0 EX. LAVATORY 1 1.0 1.0 2.0 2.0 FLOOR DRAIN 3 2.0 6.0 - - MOP SINK 1 2.0 2.0 3.0 3.0 SINK 3 2.0 6.0 3.0 9.0 DUMP SINK 1 2.0 2.0 3.0 3.0 KITCHEN SINK 1 2.0 2.0 4.0 4.0 SODA MACHINE 1 - - 2.0 2.0 REGENCY 6005118188 22.0 1/2" 28.0 SERVICE SIZE REQ. VENTWASTE - 1 COMPARTMENT SINK WATER EAGLE GROUP a a 1/2" a PLUMBING FIXTURE SCHEDULE: FIXTURES IN THIS SCHEDULE OR THEIR APPROVED EQUIVALENT ARE PROVIDED BY THE PLUMBING CONTRACTOR. SUBMIT SHOP DRAWINGS ON EACH OF THESE ITEMS. REFER TO SPECIFICATIONS FOR FURTHER INFORMATION AND INSALLATION REQUIREMENTS. VERIFY ROUGH -IN REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSRUCTIONS AND INSTALL PER MANUFACTURER'S RECOMMENDATIONS. REFER TO THE ARCHITECTURAL DRAWINGS FOR THE PLUMBING FIXTURE MOUNTING HEIGHTS. FLOOR DRAIN: JAY R. SMITH #2005L (-A), CAST IRON BODY AND CLAMPING COLLAR, ® ADJUSTABLE 6" ROUND NICKEL BRONZE STRAINER. USE PUSH -ON JOINT OF OUTLET SIZE AS SHOWN ON PLANS. CLEANOUT: JAY R. SMITH, CAST IRON BODY, FLANGE WITH CLAMPING COLLAR, ABS PLUG AND CO ADJUSTABLE, ROUND, SECURED, NICKEL BRONZE TOP. GT GREASE INTERCEPTOR: ZURN, MODEL #1170, SIZE: 500. © BACKFLOW PREVENTER: WILKENS, MODEL #975XL, 1". PLUMBING EQUIPMENT SCHEDULE TAG MANUFACTURER MODEL CW HW DRAIN VOLTAGE PHASE AMP DESCRIPTION E REGENCY 60OS31620218 1/2" 1/2" 2" - - - 3 COMPARTMENT SINK F REGENCY 600SM16206 1/2" 1/2" 4. - - - FLOOR MOUNTED MOP SINK G T.B.D. T.B.D. 1/2" 1/2" 3" - - - 1 COMPARTMENT SINK H REGENCY 600HS12SP 1/2" 1/2" 2" - - - SPACE SAVER HAND SINK N REGENCY 6005118188 1/2" 1/2" 2" - - - 1 COMPARTMENT SINK R EAGLE GROUP SR10-14-5-1 1/2" 1/2" 2" _ _ _ DROP IN HAND SINK T AO SMITH DEN -40 3/4" 3/4" 3/4" ID 208 3 27.7 WATER HEATER Project Name and Address MAIN STREET POKE 110 WEST MAIN STREET CARMEL, IN 46032 Firm Name and Address PROVIDE CLEANOUT TEE WITH I I COLUMN OR PARTION AS COUNTERSUNK ABS PLASTIC SHOWN ON FLOOR PLAN FLOOR PLUG: TAPERED -THREAD WITH I I (� \logos\Logo with Address, jpg TFE JOINT COMPOUND I I WHERE CLEANOUT TEE IS CONCEALED IN A CHASE OR PARTITION, PROVIDE A ROUND 18 GAUGE STAINLESS STEEL COVER WITH BEVELED EDGES AND FLATHEAD MACHINE SCREW FINISHED FLOOR-\ ° n STRUCTURAL PRECAST FLOOR =Cr -4 U� SANITARY PIPE PIPE cm��/ we DIRECTION FLOW 1 /8 BEND, IF CLEANOUT DIRECTION OF FLOW OCCURS AT END OF PIPE FLOOR CLEANOUT WALL CLEANOUT NOTES: 1. LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS OF PIPE GREATER THAN 45 DEGREES, AT 50' INTERVALS ON STRAIGHT RUNS, AND WHERE SHOWN ON PLANS. PROVIDE BACKFILL PER ARCHITECTURAL SPECIFICATIONS. LOCATE CLEANOUTS WHERE THERE IS 18" CLEAR AROUND. CONSULT LOCAL CODES FOR OTHER FCO REQUIREMENTS. 2. FLOOR CLEANOUTS NOT TO BE LOCATED IN CARPETED AREAS. 3. PROVIDE WALL CLEANOUTS (WCO) WHERE SHOWN ON PLAN AND ON 4 SANITARY BRACHES NOT SERVED BY A FLOOR CLEANOUT: LOCATED �V ABOVE FIXTURE FLOOD RIM WITHIN 4" OF FLOOR. CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS. 1 1/2" SANITARY CLEANOUT DETAILS SANITARY AND VENT RISER DIAGRAM NOT TO SCALE 0 Se NOT TO SCALE THREE COMPARTMENT SINK 2" V IN WALL -7 CLEANOUTS IN ENDS OF PIPE - FLOOR J GREASE TRAP ROUTE COMBINED SANITARY DRAIN LINE TO WALL. ROUTE VENT UP, AND SANITARY DOWN AS SHOWN ON PLANS. ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS OR MEET LOCAL CODE REQUIREMENTS. HUBLESS CAST IRON PIPE, FITTINGS AND CONNECTORS ALL AROUND SINK AND TRAP. CONNECT TRAP FROM CENTER COMPARTMENT. 3- COMPARTMENT SINK DETAIL NOT TO SCALE TOPPING SLAB FINISH FLOOR O 9•, r -STRUCTURAL PRECAST FLOOR a �d . TRAP REQUIRED- BUT NOT SHOWN AS PART OF INSTILLATION DETAIL FLOOR DRAIN DETAIL WOOD JOILST ALL -THREAD ROD. LENGTH AS REQUIRED TOP BEAM C -CLAMP, FOR PIPE SLOPE IF STEEL BAR JOIST PROVIDE COPPER OR NON-METALLIC COATING WHERE CLEVIS HANGER FOR HANGERS CONTACT PIPE OVER FOUR INCH BARE COPPER PIPE .-.Alb ADJUSTABLE BAND HANGER FOUR INCH OR LESS PIPES DO NOT HANG PIPE PROVIDE GALVANIZED STEEL SADDLE FOR ALL LARGER THAN 3" FROM INSULATED PIPE LARGER THAN 3/4". VERIFY BOTTOM OF JOISTS. INSULATION THICKNESS WHEN SIZING HANGERS. PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN HERE. DO NOT INSTALL HANGER INSIDE INSULATION OR OTHERWISE PENETRATE VAPOR BARRIER. DO NOT HANG ONE PIPE FROM ANOTHER EXCEPT IN CHASES. TRAPEZE HANGERS MAY BE USED FOR MULTIPLE PARALLEL PIPES. HANGER 1 SPACING FOR 1 /P4E 7 SIZE: 1 "=6' 3/4 =6, 11//2"35'.1 CAST Id(ON 10' AND ONE NEAR ALL JOINTS. STEEL: 4"=14' 3"=12 2-1/2"=11 2"=10' 1-1/0=9' 1"=7' 3/4"=6' 1/2"=5'. LOCATE HANGERS AS CLOSE AS POSSIBLE TO TURNS AND TES OF PIPE. PROVIDE SUPPLEMENTARY STEEL STRUTS BETWEEN JOISTS IF REQUIRED.LOCATE HANGERS TO TAKE LOAD OFF OF EQUIPMENT CONNECTIONS. ANCHOR WATER PIPE AGAINST SWAYING DUE TO CHANGES IN WATER VELOCITY. PROVIDE SEISMIC BRACING IF AS REQUIRED BY LOCAL AUTHORITIES. CHAINS OR PERFORATED STRAP IRON OR STEEL IS NOT ACCEPTABLE. REFER TO CODES FOR FURTHER INFORMATION. PIPE SUPPORT DETAIL NOT TO SCALE CLEANOUT FACE SHALL BE WITHIN 4" OF WALL SURFACE. PROVIDE PIPE EXTENSION, IF REQUIRED. n. Al FLOOR PLAN - SANITARY AND VENT PIPING WORK SCALE: 3/16" = 1'-0" KEY NOTES 1. EXISTING TOILET ROOM TO REMAIN. NO WORK REQUIRED. 2. NEW GREASE TRAP, SEE 3 - COMPARTMENT SINK DETAIL ON THIS SHEET. ZURN MODEL: Z1170, SIZE: 500 3. EXACT LOCATION OF EXISTING SANITARY AND DIRECTION OF FLOW UNKNOWN, LOCATION SHOWN ON DRAWINGS IS APPROXIMATE. CONTRACTOR TO FIELD VERIFY EXACT LOCATION OF EXISTING SANITARY AND DIRECTION OF FLOW. 4. PROVIDE AIR ADMITTANCE VALVE (AAV) ABOVE CEILING. 5. EXTEND AND CONNECT TO EXISTING SANITARY IN AREA. CUT AND PATCH AS REQUIRED. TENANT AND GC TO UTILIZE THE EXISTING WATER SUBMETER. IF ANY CHANGES OCCUR, THE TENANT IS RESPONSIBLE FOR PROVIDING A NEW SUBMETER FROM SPEEDREAD THAT IS COMPATIBLE WITH THE CURRENT SYSTEM BEING READ BY URS. )RESTROOMEd 103 1 1/2" H 1/2"CW 1" CW 3/4" H RP )/2" HW �IIW 1/2" HW = 1/2" HW M. HALLWAY I � I 1/2- CW KITCHEN 102 1/2- CW 3/4" HW ASSEMBLY 101 I I I I I O FLOOR PLAN - WATER PIPING WORK SCALE: 3/16" = 1'-0" KEY NOTES O 1. EXISTING TOILET ROOM TO REMAIN. NO WORK REQUIRED. 2. EXISTING COLD WATER SERVICE TO BUILDING. CONTRACTOR TO FIELD VERIFY EXACT LOCATION AND SIZE. 3. EXISTING COLD WATER SUPPLY TO SPACE AND EXISTING WATER METER. CONTRACTOR TO FIELD VERIFY EXISTING SERVICE SIZE, AND INCREASE SIZE OF SUPPLY PIPING AND METER AS REQUIRED TO MEET DEMAND. CONTRACTOR WILL INCLUDE REPLACEMENT OF METER AND COLD WATER SUPPLY PIPE IN BASE BID. 4. TIE INTO SPACE COLD WATER SERVICE AFTER WATER METER AS REQUIRED TO MAINTAIN SERVICE TO EXISTING FIXTURES. LOCATION SHOWN ON DRAWINGS IS APPROXIMATE. THIS DRAWING SET IS PROVIDED IN CONFIDENCE AND SHALL BE USED ONLYAS INTENDED BY THE AGREEMENT WITH LEHNER DESIGNS. NO OTHER USE OR DUPLICATION MAYBE MADE WITHOUT PRIOR WRITTEN CONSENT OF LEHNER DESIGNS. ALL COMMON LAW RIGHTS OF COPYRIGHT ARE SPECIFICALLY RESERVED. SP--N"U f 1533 EAST NORTHFIELD DRIVE SUITE 400 W SPECGWWNERMEPCOM N1,0011111111 No STF�'///i No. _--a 10403982: A.•• i STATE OF i N DIA J FLOOR PLAN PLUMBING WORK Designed By Revision/Issue Date NDLORD COMMENTS 2/6/2017 FLA Approved By 3/16"=1'-0" N1,0011111111 No STF�'///i No. _--a 10403982: A.•• i STATE OF i N DIA J FLOOR PLAN PLUMBING WORK Designed By PLAN NORTH AB Checked By MWC Date 1 /20/2017 Approved By Project Sheet #100303 P 1 Date 1 /20/2017 Scale 3/16"=1'-0"