Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LR008_JONES_AS-DESIGNED
BUILDING FILE REPORT File Name: LR008_JONES_CODE.blg Date: April 03, 2017 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Property/Builder: Organization Building Name: LR008 Org. Name: TSI ENERGY SOLUTIONS Owner's Name: JONES BUILDING GROUP Address: P.O. BOX 705 Property Address: 10523 LAUREL RIDGE LN City, St, Zip: CARMEL, IN 46082 City, St, Zip: CARMEL (AS DESIGNED), IN 46032 Phone No: 317-846-4655 Phone No: Website: www.tsienergysolutions.com Builder's Name: JONES BUILDING GROUP Rater's Name: DEVIN SIELSCHOTT Phone No: Rater's Email: dsielschott@tsienergysolutions.com Email Address: Rater's ID: 5701119 Model: ALLAM RESIDENCE Provider ID: 1998-053 Development: LAUREL RIDGE 8 Sample Set ID: 0000 Permit Date/Number: Rating Date: 04-03-2017 Rating Type: Projected Rating Reason: New Home Rating No.: Registry ID: Verifier's Name: Verifier's ID: Verifier's Name:: Verifier's ID: Verifier's Name:: Verifier's ID: Verifier's Name: Verifier's ID: BUILDING FILE REPORT LR008 Page 2 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. General Building Information Area of Cond. Space(sq ft): 20460 Volume of Cond. Space: 247380 Year Built: 2017 Housing Type: Single-family detached Level Type(Apartments Only): None Floors on or Above-Grade: 2 Number of Bedrooms: 5 Foundation Type: More than one type Enclosed Crawl Space Type: Unvented Number of Stories Including Conditioned Basement: 3 Thermal Boundary Location: REM Default Foundation Wall Info: 1 2 3 Name COND/AMB COND/GAR CRAWL/AMB Library Type Uninsulated Uninsulated R-10 Draped, Full Length(ft) 322.0 32.0 223.0 Total Height(ft) 10.0 10.0 3.0 Depth Below Grade(ft) 9.0 9.0 2.0 Height Above Grade(ft) 1.0 1.0 1.0 Location Cond->ambient/grnd Cond->garage/grnd Cond crwl->amb/grnd Uo Value (wall, airfilm, & soil) 0.171 0.171 0.077 Uo Value (wall assembly only) 1.205 1.205 0.094 Foundation Wall: Uninsulated Type: Solid concrete or stone Thickness(in): 10.0 Studs: None Interior Insulation: Continuous R-Value: 0.0 Frame Cavity R-Value: 0.0 Cavity Insulation Grade: 1 Ins top: 0.0 ft from top of wall Ins Bottom: 0.0 ft from bottom of wall Exterior Insulation: R-Value: 0.0 Ins top: 0.0 ft from top of wall Ins bottom: 0.0 ft below grade Note: BUILDING FILE REPORT LR008 Page 3 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Foundation Wall: R-10 Draped, Full Type: Solid concrete or stone Thickness(in): 8.0 Studs: None Interior Insulation: Continuous R-Value: 10.0 Frame Cavity R-Value: 0.0 Cavity Insulation Grade: 1 Ins top: 0.0 ft from top of wall Ins Bottom: 0.0 ft from bottom of wall Exterior Insulation: R-Value: 0.0 Ins top: 0.0 ft above grade Ins bottom: 0.0 ft from bottom of wall Note: Slab Floor Info: 1 Name BSMT Library Type Uninsulated Area(sq ft) 7152 Depth Below Grade(ft) 9.0 Full Perimeter(ft) 426 Exposed Perimeter(ft) 426 On-Grade Perimeter(ft) 0 Slab Floor: Uninsulated Slab Covering None Perimeter Insulation (R-Value): 0.0 Perimeter Insulation Depth (ft): 0.0 Under-Slab Insulation (R-Value): 0.0 Under-Slab Insulation Width (ft): 0.0 Slab Insulation Grade: 1 Radiant Slab: No Note: Floor Info: 1 Name OVER CRAWL Library Type Uninsulated Area (sq ft) 1622 Location Btwn cond & cond (adiabatic) Uo Value 0.292 BUILDING FILE REPORT LR008 Page 4 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Floor: Uninsulated Information From Quick Fill Screen: Continous Insulation R-Value 0.0 Cavity Insulation R-Value 0.0 Cavity Insulation Thickness (in.) 0.0 Cavity Insulation Grade 1.0 Joist Size (w x h, in) 1.5 x 9.5 Joist Spacing (in oc) 16.0 Framing Factor - (default) 0.1300 Floor Covering CARPET Note: Layers Paths Cavity Framing Grade Inside Air Film 0.920 0.920 0.920 Floor covering 1.230 1.230 1.230 Subfloor 0.820 0.820 0.820 Cavity ins 0.000 0.000 0.000 Continuous ins 0.000 0.000 0.000 Framing 0.000 0.000 0.000 0.000 0.000 0.000 Outside Air Film 0.455 0.455 0.455 Total R-Value 3.425 3.425 3.425 U-Value 0.292 0.292 0.292 Relative Area 0.870 0.130 0.000 UA 0.254 0.038 0.000 Total Component UA: 0.292 Total Component Area: 1.0 Component Uo: 0.292 BUILDING FILE REPORT LR008 Page 5 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Rim and Band Joist: 1 2 3 Name COND/AMB COND/GAR COND/ATTIC Area(sq ft) 636.0 32.0 167.0 Continuous Ins 0.5 0.5 0.5 Framed Cavity Ins 19.0 19.0 15.0 Cavity Ins Thk(in) 5.5 5.5 3.5 Joist Spacing 16.0 16.0 16.0 Insulation Grade 1 1 1 Location Cond -> ambient Cond -> garage Cond -> attic Uo Value 0.049 0.049 0.061 Above-Grade Wall: 1 2 3 Name COND/AMB COND/GAR COND/ATTIC Library Type G1 R-19, OSB 2x6 G1 R-19, 2x6 GAR G1 R-19, OSB 2x6 Gross Area(sq ft) 9234.00 384.00 1976.00 Exterior Color Medium Medium Medium Location Cond -> ambient Cond -> garage Cond -> attic Uo Value 0.058 0.058 0.058 BUILDING FILE REPORT LR008 Page 6 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Above-Grade Wall: G1 R-19, OSB 2x6 Information From Quick Fill Screen: Standard Wood Frame Continuous Insulation (R-Value) 0.5 Frame Cavity Insulation (R-Value) 19.0 Frame Cavity Insulation Thickness (in) 5.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in) 1.5 x 5.5 Stud Spacing (in o.c.) 24.0 Framing Factor - (default) 0.1988 Gypsum Thickness (in) 0.5 Note: Layers Paths Cavity Framing Grade Inside Air Film 0.680 0.680 0.680 Gyp board 0.450 0.450 0.450 Air Gap/Frm 0.000 0.000 0.000 Cavity ins/Frm 19.000 6.875 1.030 Continuous ins 0.500 0.500 0.500 Ext Finish 0.940 0.940 0.940 0.000 0.000 0.000 Outside Air Film 0.170 0.170 0.170 Total R-Value 21.740 9.615 3.770 U-Value 0.046 0.104 0.265 Relative Area 0.801 0.199 0.000 UA 0.037 0.021 0.000 Total Component UA: 0.058 Total Component Area: 1.0 Component Uo: 0.058 BUILDING FILE REPORT LR008 Page 7 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Above-Grade Wall: G1 R-19, 2x6 GAR Information From Quick Fill Screen: Standard Wood Frame Continuous Insulation (R-Value) 0.0 Frame Cavity Insulation (R-Value) 19.0 Frame Cavity Insulation Thickness (in) 5.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in) 1.5 x 5.5 Stud Spacing (in o.c.) 24.0 Framing Factor - (default) 0.1988 Gypsum Thickness (in) 1.0 Note: Layers Paths Cavity Framing Grade Inside Air Film 0.680 0.680 0.680 Gyp board 0.900 0.900 0.900 Air Gap/Frm 0.000 0.000 0.000 Cavity ins/Frm 19.000 6.875 1.030 Continuous ins 0.000 0.000 0.000 Ext Finish 0.940 0.940 0.940 0.000 0.000 0.000 Outside Air Film 0.170 0.170 0.170 Total R-Value 21.690 9.565 3.720 U-Value 0.046 0.105 0.269 Relative Area 0.801 0.199 0.000 UA 0.037 0.021 0.000 Total Component UA: 0.058 Total Component Area: 1.0 Component Uo: 0.058 BUILDING FILE REPORT LR008 Page 8 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Window Information: 1 2 3 Name FRONT FRONT SLIDER BACK Library Type U-.31, SHGC-.30 U-.31, SHGC-.30 U-.31, SHGC-.30 U-Value 0.310 0.310 0.310 SHGC 0.300 0.300 0.300 Area(sq ft) 396.00 48.00 458.00 Orientation South South North Overhang Depth 0.0 0.0 0.0 Overhang To Top 0.0 0.0 0.0 Overhang To Bottom 0.0 0.0 0.0 Interior Winter Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Winter Shading None None None Adjacent Summer Shading None None None Wall Assignment AGWall 1 AGWall 1 AGWall 1 Window Information: 4 5 6 Name BACK SLIDER BACK SLIDER BACK SLIDER Library Type U-.31, SHGC-.30 U-.31, SHGC-.30 U-.31, SHGC-.30 U-Value 0.310 0.310 0.310 SHGC 0.300 0.300 0.300 Area(sq ft) 48.00 48.00 48.00 Orientation North North North Overhang Depth 0.0 0.0 0.0 Overhang To Top 0.0 0.0 0.0 Overhang To Bottom 0.0 0.0 0.0 Interior Winter Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Winter Shading None None None Adjacent Summer Shading None None None Wall Assignment AGWall 1 AGWall 1 AGWall 1 BUILDING FILE REPORT LR008 Page 9 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Window Information: 7 8 9 Name BACK SLIDER LEFT RIGHT Library Type U-.31, SHGC-.30 U-.31, SHGC-.30 U-.31, SHGC-.30 U-Value 0.310 0.310 0.310 SHGC 0.300 0.300 0.300 Area(sq ft) 48.00 192.00 155.00 Orientation North West East Overhang Depth 0.0 0.0 0.0 Overhang To Top 0.0 0.0 0.0 Overhang To Bottom 0.0 0.0 0.0 Interior Winter Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Winter Shading None None None Adjacent Summer Shading None None None Wall Assignment AGWall 1 AGWall 1 AGWall 1 Window: U-.31, SHGC-.30 U-Value: 0.310 Solar Heat Gain Coefficient: 0.300 Note: Door Information: 1 2 Name FRONT GARAGE Opaque Area(sq ft) 60.0 24.0 Library Type Steel-urth w/brk Steel-urth w/brk Wall Assignment AGWall 1 AGWall 2 Uo Value 0.187 0.187 Door: Steel-urth w/brk R-Value of Opaque Area: 4.4 Storm Door: No Note: Roof Information: 1 Name SECOND Library Type R-38 Blown, Attic, 1 Ceiling Area(sq ft) 8774.00 Roof Area(sq ft) 8774.00 Color Medium Radiant Barrier No Type(Attic) Attic Uo Value 0.026 Clay or Cement Tiles: No Sub Roof Ventilation: No BUILDING FILE REPORT LR008 Page 10 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Ceiling: R-38 Blown, Attic, 1 Information From Quick Fill Screen: Continous Insulation (R-Value) 25.0 Cavity Insulation (R-Value) 13.0 Cavity Insulation Thickness (in) 3.5 Cavity Insulation Grade 1 Gypsum Thickness (in) 0.500 Insulated Framing Size(w x h, in) 1.5 x 3.5 Insulated Framing Spacing (in o.c.) 24.0 Framing Factor - (default) 0.1100 Ceiling Type Attic Note: Layers Paths Framing Cavity Grade Inside Air Film 0.610 0.610 0.610 Gyp board 0.450 0.450 0.450 Cavity Ins/Frm 4.375 13.000 0.000 Continuous ins 25.000 25.000 25.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Outside Air Film 0.610 0.610 0.610 Total R-Value 31.045 39.670 26.670 U-Value 0.032 0.025 0.037 Relative Area 0.110 0.890 0.000 UA 0.004 0.022 0.000 Total Component UA: 0.026 Total Component Area: 1.0 Component Uo: 0.026 Mechanical Equipment: General Number of Mechanical Systems: 9 Heating SetPoint(F): 68.00 Heating Setback Thermostat: Present Cooling SetPoint(F): 78.00 Cooling Setup Thermostat: Present BUILDING FILE REPORT LR008 Page 11 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Heat: 912SB66120SA24 SystemType: Fuel-fired air distribution Fuel Type: Natural gas Rated Output Capacity (kBtuh): 112.0 Seasonal Equipment Efficiency: 92.1 AFUE Auxiliary Electric: 1193 Eae Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 29 Number Of Units: 1 Heat: 912SA48100S17A SystemType: Fuel-fired air distribution Fuel Type: Natural gas Rated Output Capacity (kBtuh): 93.0 Seasonal Equipment Efficiency: 92.1 AFUE Auxiliary Electric: 756 Eae Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 24 Number Of Units: 1 Heat: 912SA48100S17A SystemType: Fuel-fired air distribution Fuel Type: Natural gas Rated Output Capacity (kBtuh): 93.0 Seasonal Equipment Efficiency: 92.1 AFUE Auxiliary Electric: 756 Eae Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 24 Number Of Units: 1 BUILDING FILE REPORT LR008 Page 12 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Heat: 912SA48100S17A SystemType: Fuel-fired air distribution Fuel Type: Natural gas Rated Output Capacity (kBtuh): 93.0 Seasonal Equipment Efficiency: 92.1 AFUE Auxiliary Electric: 756 Eae Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 24 Number Of Units: 1 Cooling Equipment: CA13NA060 System Type: Air conditioner Fuel Type: Electric Rated Output Capacity (kBtuh): 58.2 Seasonal Equipment Efficiency: 13.0 SEER Sensible Heat Fraction (SHF): 0.70 Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 36 Number Of Units: 1 Cooling Equipment: CA13NA036 System Type: Air conditioner Fuel Type: Electric Rated Output Capacity (kBtuh): 34.2 Seasonal Equipment Efficiency: 13.0 SEER Sensible Heat Fraction (SHF): 0.70 Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 21 Number Of Units: 1 BUILDING FILE REPORT LR008 Page 13 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Cooling Equipment: CA13NA036 System Type: Air conditioner Fuel Type: Electric Rated Output Capacity (kBtuh): 34.2 Seasonal Equipment Efficiency: 13.0 SEER Sensible Heat Fraction (SHF): 0.70 Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 21 Number Of Units: 1 Cooling Equipment: CA13NA036 System Type: Air conditioner Fuel Type: Electric Rated Output Capacity (kBtuh): 34.2 Seasonal Equipment Efficiency: 13.0 SEER Sensible Heat Fraction (SHF): 0.70 Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 21 Number Of Units: 1 Water Heating Equipment: RG1PV75S6N Water Heater Type: Conventional Fuel Type: Natural gas Energy Factor: 0.65 Recovery Efficiency: 0.80 Water Tank Size (gallons): 75 Extra Tank Insulation (R-Value): 0.0 Note: Location: Conditioned area Percent Load Served: 100 Performance Adjustment: 100 Number Of Units: 1 BUILDING FILE REPORT LR008 Page 14 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. DHW Efficiencies All bath faucets & showers <= 2gpm: false All DHW pipes fully insulated >= R-3: false Recirculation type: None (standard system) Farthest fixture to DHW heater 134 TOTAL Pipelength for longest DHW run: 164 DWHR unit present?: false Duct System Information: Name SYSTEM 1 Heating System 912SB66120SA24 Cooling System CA13NA060 Supply Area(sq ft) 372.6 Return Area(sq ft) 345.0 Conditioned Floor Area(sq ft) 5115.0 # of Registers 6 Duct Leakage Qualitative Assessment - Not Applicable Duct Leakage to Outside: 204.00 CFM @ 25 Pascals Supply Duct Leakage - Not Applicable Return Duct Leakage - Not Applicable Total Duct Leakage: 264.00 CFM @ 25 Pascals Duct Tightness Test: Postconstruction Test Duct Information: 3 4 Type Supply Return Percent Area 100.0 100.0 R-Value 6.0 6.0 Location Conditioned space Conditioned space BUILDING FILE REPORT LR008 Page 15 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Duct System Information: Name SYSTEM 2 Heating System 912SA48100S17A Cooling System CA13NA036 Supply Area(sq ft) 236.5 Return Area(sq ft) 218.9 Conditioned Floor Area(sq ft) 5115.0 # of Registers 5 Duct Leakage Qualitative Assessment - Not Applicable Duct Leakage to Outside: 204.00 CFM @ 25 Pascals Supply Duct Leakage - Not Applicable Return Duct Leakage - Not Applicable Total Duct Leakage: 408.00 CFM @ 25 Pascals Duct Tightness Test: Postconstruction Test Duct Information: 3 4 Type Supply Return Percent Area 100.0 100.0 R-Value 6.0 6.0 Location Conditioned space Conditioned space Duct System Information: Name SYSTEM 3 Heating System 912SA48100S17A Cooling System CA13NA036 Supply Area(sq ft) 236.5 Return Area(sq ft) 218.9 Conditioned Floor Area(sq ft) 5115.0 # of Registers 5 Duct Leakage Qualitative Assessment - Not Applicable Duct Leakage to Outside: 204.00 CFM @ 25 Pascals Supply Duct Leakage - Not Applicable Return Duct Leakage - Not Applicable Total Duct Leakage: 400.00 CFM @ 25 Pascals Duct Tightness Test: Postconstruction Test Duct Information: 1 2 3 Type Supply Return Supply Percent Area 90.0 90.0 10.0 R-Value 30.0 30.0 6.0 Location Attic, under insulation Attic, under insulation Conditioned space BUILDING FILE REPORT LR008 Page 16 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Duct Information: 4 Type Return Percent Area 10.0 R-Value 6.0 Location Conditioned space Duct System Information: Name SYSTEM 4 Heating System 912SA48100S17A Cooling System CA13NA036 Supply Area(sq ft) 236.5 Return Area(sq ft) 218.9 Conditioned Floor Area(sq ft) 5115.0 # of Registers 5 Duct Leakage Qualitative Assessment - Not Applicable Duct Leakage to Outside: 250.00 CFM @ 25 Pascals Supply Duct Leakage - Not Applicable Return Duct Leakage - Not Applicable Total Duct Leakage: 400.00 CFM @ 25 Pascals Duct Tightness Test: Postconstruction Test Duct Information: 1 2 3 Type Supply Return Supply Percent Area 90.0 90.0 10.0 R-Value 30.0 30.0 6.0 Location Attic, under insulation Attic, under insulation Conditioned space Duct Information: 4 Type Return Percent Area 10.0 R-Value 6.0 Location Conditioned space BUILDING FILE REPORT LR008 Page 17 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Infiltration and Mechanical Ventilation Whole House Infiltration Measurement Type: Blower door test Heating Season Infiltration Value: 5.00 ACH @ 50 Pascals Cooling Season Infiltration Value: 5.00 ACH @ 50 Pascals Shelter Class 4 Code Verification: Tested Mechanical Ventilation for IAQ Type: None Rate(cfm): 0 Sensible Recovery Efficiency(%): 0.00 Total Recovery Efficiency(%): 0.00 Hours per Day: 24.00 Fan Power (watts): 0.00 ECM Fan Motor: false Ventilation Strategy for Cooling Cooling Season Ventilation: Natural Ventilation Lights and Appliances Simplified Audit Refrigerator KWh: 727 Refrigerator Location: Conditioned Dishwasher EF: 0.46 Dishwasher kWh/yr: 0 Dishwasher Capacity: 12 Dishwasher kWh/Year: 0 Range/Oven Fuel Type: Natural gas Induction Range: No Convection Oven: No Clothes Dryer Fuel Type: Electric Clothes Dryer Location: Conditioned Clothes Dryer Moisture Sensing: No Clothes Dryer Energy Factor: 3.01 Clothes Dryer Gas Energy Factor: 2.67 Clothes Washer Location: Conditioned Clothes Washer LER: 704.0 Clothes Washer MEF: 0.817 Clothes Washer Capacity: 2.874 Clothes Washer Electricity Rate: 0.08 BUILDING FILE REPORT LR008 Page 18 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Lights and Appliances Clothes Washer Gas Rate: 0.58 Clothes Washer Annual Gas Cost: 23.00 Percent CFLs: 0.0 Percent Fluorescent: 10.0 Percent Exterior Lights: 0.0 Percent Garage Lights: 0.0 Ceiling Fan CFM / Watt: 0.00 Mandatory Requirements IECC Requirements Verified IECC 04: true Verified IECC 06: true Verified IECC 09: true Verified IECC 12: false Verified IECC 15: false Verified NY-ECCC 2010: false Verified Michigan: false Rater certifies that the home complies with the following requirements for: None Rater Design Review Checklist (National) Rater Field Checklist(National) HVAC Design Report HVAC Commissioning Checklist (optional) ENERGY STAR Version 3 Appliances Refrigerators: 0 Ceiling Fans: 0 Exhaust Fans: 0 Dishwashers: 0 ENERGY STAR Version 3 Basements Basement Wall Area 50% Below Grade: true Basement Floor Area: 7152 2009 IECC Prescriptive Requirements for ENERGY STAR v3.0 false Slab Insulation Exemption: false Indoor airPlus Verification Checklist: false EPA Field App ID ENERGY CODE INSPECTION CHECKLIST Date: April 03, 2017 Rating No.: Building Name: LR008 Rating Org.: TSI ENERGY SOLUTIONS Owner's Name: JONES BUILDING GROUP Phone No.: 317-846-4655 Property: 10523 LAUREL RIDGE LN Rater's Name: DEVIN SIELSCHOTT Address: CARMEL (AS DESIGNED), IN 46032 Rater's No.: 5701119 Builder's Name: JONES BUILDING GROUP Weather Site: Indianapolis, IN Rating Type: Projected Rating File Name: LR008_JONES_CODE.blg Rating Date: 04-03-2017 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Building Information: Conditioned Area (sq ft): 20460 Conditioned Volume (cubic ft): 247380 Insulated Shell Area (sq ft): 32564 The building assemblies and the energy features listed below have been modeled to demonstrate compliance with the IECC utilizing the Simulated Performance Path. At times the energy features listed below will change in the field from what has been input in the analysis. TSI ENERGY SOLUTIONS's field inspection process will identify any changes to ensure that the home continues to meet the intent of the IECC. Reports and certificates will be furnished before CO to ensure that the house meets the intent of the IECC. Ceilings: [ ] 1. Attic: R-38 Blown, Attic, 1 (8774 s.f.) R-25.0 continuous insulation, R-13.0 cavity insulation. Name: SECOND Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Above-Grade Walls: [ ] 1. Wall: G1 R-19, OSB 2x6 (9234 s.f.), Between conditioned space and ambient R-0.5 continuous insulation, R-19.0 cavity insulation. Name: COND/AMB Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 2. Wall: G1 R-19, 2x6 GAR (384 s.f.), Between conditioned space and garage R-0.0 continuous insulation, R-19.0 cavity insulation. Name: COND/GAR Insulation Grade: I II III Face / Inset ENERGY CODE INSPECTION CHECKLIST LR008 Page 2 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Comments/Location___________________________________________________________ [ ] 3. Wall: G1 R-19, OSB 2x6 (1976 s.f.), Between conditioned space and attic R-0.5 continuous insulation, R-19.0 cavity insulation. Name: COND/ATTIC Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Windows and Skylights: Window-to-Wall Area Ratio: 0.12 [ ] 1. Window: U-.31, SHGC-.30 (396 s.f., South), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: FRONT Orientation: South Comments/Location___________________________________________________________ [ ] 2. Window: U-.31, SHGC-.30 (48 s.f., South), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: FRONT SLIDER Orientation: South Comments/Location___________________________________________________________ [ ] 3. Window: U-.31, SHGC-.30 (458 s.f., North), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: BACK Orientation: North Comments/Location___________________________________________________________ [ ] 4. Window: U-.31, SHGC-.30 (48 s.f., North), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: BACK SLIDER Orientation: North Comments/Location___________________________________________________________ [ ] 5. Window: U-.31, SHGC-.30 (48 s.f., North), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: BACK SLIDER Orientation: North Comments/Location___________________________________________________________ [ ] 6. Window: U-.31, SHGC-.30 (48 s.f., North), U-Value: 0.310, SHGC: 0.300 ENERGY CODE INSPECTION CHECKLIST LR008 Page 3 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. For windows without labeled U-factors, describe features: Name: BACK SLIDER Orientation: North Comments/Location___________________________________________________________ [ ] 7. Window: U-.31, SHGC-.30 (48 s.f., North), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: BACK SLIDER Orientation: North Comments/Location___________________________________________________________ [ ] 8. Window: U-.31, SHGC-.30 (192 s.f., West), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: LEFT Orientation: West Comments/Location___________________________________________________________ [ ] 9. Window: U-.31, SHGC-.30 (155 s.f., East), U-Value: 0.310, SHGC: 0.300 For windows without labeled U-factors, describe features: Name: RIGHT Orientation: East Comments/Location___________________________________________________________ Doors: [ ] 1. Door: Steel-urth w/brk (60 s.f.), R-Value 4.4 Comments/Location___________________________________________________________ [ ] 2. Door: Steel-urth w/brk (24 s.f.), R-Value 4.4 Comments/Location___________________________________________________________ Floors: [ ] 1. Floor: Uninsulated (1622 s.f.), Between conditioned space and another (adiabatic) R-0.0 continuous insulation, R-0.0 cavity insulation. Name: OVER CRAWL Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Foundation Walls: ENERGY CODE INSPECTION CHECKLIST LR008 Page 4 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. [ ] 1. Wall: Uninsulated (3220 s.f.), Between conditioned space and ambient/ground R-0.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: COND/AMB Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 2. Wall: Uninsulated (320 s.f.), Between conditioned space and garage/ground R-0.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: COND/GAR Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 3. Wall: R-10 Draped, Full (669 s.f.), Between conditioned crawl space and ambient/ground R-10.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: CRAWL/AMB Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Slab Floors: [ ] 1. Slab: Uninsulated (7152 s.f.) R-0.0 perimeter insulation, R-0.0 under slab insulation. Name: BSMT Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Rim and Band Joists: [ ] 1. Joist: COND/AMB (636 s.f.), Between conditioned space and ambient R-0.5 continuous insulation, R-19.0 cavity insulation. Name: COND/AMB Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 2. Joist: COND/GAR (32 s.f.), Between conditioned space and garage R-0.5 continuous insulation, R-19.0 cavity insulation. Name: COND/GAR Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 3. Joist: COND/ATTIC (167 s.f.), Between conditioned space and attic R-0.5 continuous insulation, R-15.0 cavity insulation. Name: COND/ATTIC Insulation Grade: I II III Face / Inset ENERGY CODE INSPECTION CHECKLIST LR008 Page 5 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Comments/Location___________________________________________________________ Mechanical Equipment: [ ] 1. Heating: Fuel-fired air distribution, Natural gas, 92.1 AFUE. Make and Model Number:_____________________________________________________ [ ] 2. Heating: Fuel-fired air distribution, Natural gas, 92.1 AFUE. Make and Model Number:_____________________________________________________ [ ] 3. Heating: Fuel-fired air distribution, Natural gas, 92.1 AFUE. Make and Model Number:_____________________________________________________ [ ] 4. Heating: Fuel-fired air distribution, Natural gas, 92.1 AFUE. Make and Model Number:_____________________________________________________ [ ] 5. Cooling: Air conditioner, Electric, 13.0 SEER. Make and Model Number:_____________________________________________________ [ ] 6. Cooling: Air conditioner, Electric, 13.0 SEER. Make and Model Number:_____________________________________________________ [ ] 7. Cooling: Air conditioner, Electric, 13.0 SEER. Make and Model Number:_____________________________________________________ [ ] 8. Cooling: Air conditioner, Electric, 13.0 SEER. Make and Model Number:_____________________________________________________ [ ] 9. Water Heating: Conventional, Natural gas, 0.65 EF, 75.0 Gal. Make and Model Number:_____________________________________________________ ENERGY CODE INSPECTION CHECKLIST LR008 Page 6 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Air Leakage Control: [ ] Blower Door Test at Final __________________________ [ ] House is air-sealed so as to achieve 5.00 ACH50 or less at final blower door test. (Max CFM50 is: 20615) [ ] Visual inspection at rough for mandatory code air barrier and insulation features. INFILTRATION REQUIREMENTS FOR IECC. 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage and Insulation: [ ] Duct System 1 Leakage to Outside _________________________ and Total Duct Leakage _________________________ [ ] Duct System 1 Leakage to Outside is specified in REM/Rate at 204.000 CFM @ 25 Pascals [ ] Duct System 1 Total Duct Leakage is specified in REM/Rate at 264.000 CFM @ 25 Pascals [ ] Duct System 2 Leakage to Outside _________________________ and Total Duct Leakage _________________________ [ ] Duct System 2 Leakage to Outside is specified in REM/Rate at 204.000 CFM @ 25 Pascals [ ] Duct System 2 Total Duct Leakage is specified in REM/Rate at 408.000 CFM @ 25 Pascals [ ] Duct System 3 Leakage to Outside _________________________ and Total Duct Leakage _________________________ [ ] Duct System 3 Leakage to Outside is specified in REM/Rate at 204.000 CFM @ 25 Pascals [ ] Duct System 3 Total Duct Leakage is specified in REM/Rate at 400.000 CFM @ 25 Pascals [ ] Duct System 4 Leakage to Outside _________________________ and Total Duct Leakage _________________________ [ ] Duct System 4 Leakage to Outside is specified in REM/Rate at 250.000 CFM @ 25 Pascals [ ] Duct System 4 Total Duct Leakage is specified in REM/Rate at 400.000 CFM @ 25 Pascals DUCT LEAKAGE CODE REQUIREMENTS FOR IECC 2009 IECC Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. 2009 IECC Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. 2009 IECC Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. ENERGY CODE INSPECTION CHECKLIST LR008 Page 7 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. NOTES 2009 IECC ANNUAL ENERGY COST COMPLIANCE Date: April 03, 2017 Rating No.: Building Name: LR008 Rating Org.: TSI ENERGY SOLUTIONS Owner's Name: JONES BUILDING GROUP Phone No.: 317-846-4655 Property: 10523 LAUREL RIDGE LN Rater's Name: DEVIN SIELSCHOTT Address: CARMEL (AS DESIGNED), IN 46032 Rater's No.: 5701119 Builder's Name: JONES BUILDING GROUP Weather Site: Indianapolis, IN Rating Type: Projected Rating File Name: LR008_JONES_CODE.blg Rating Date: 04-03-2017 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Annual Energy Cost ($) 2009 IECC As Designed Heating: 4290 4442 Cooling: 1004 817 Water Heating: 185 202 SubTotal - Used to Determine Compliance: 5479 5461 Lights & Appliances: 3817 3826 Photovoltaics: -0 -0 Service Charge: 248 248 Total: 9544 9535 * Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.480 0.310 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code based on a climate zone of 5A. In fact, this home surpasses the requirements by 0.3%. Name: DEVIN SIELSCHOTT Signature: Organization: TSI ENERGY SOLUTIONS Date: April 03, 2017 * Design energy cost is based on the following systems: Heating: Fuel-fired air distribution, 112.0 kBtuh, 92.1 AFUE. Heating: Fuel-fired air distribution, 93.0 kBtuh, 92.1 AFUE. Heating: Fuel-fired air distribution, 93.0 kBtuh, 92.1 AFUE. Heating: Fuel-fired air distribution, 93.0 kBtuh, 92.1 AFUE. Cooling: Air conditioner, 58.2 kBtuh, 13.0 SEER. 2009 IECC ANNUAL ENERGY COST COMPLIANCE LR008 Page 2 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Cooling: Air conditioner, 34.2 kBtuh, 13.0 SEER. Cooling: Air conditioner, 34.2 kBtuh, 13.0 SEER. Cooling: Air conditioner, 34.2 kBtuh, 13.0 SEER. Water Heating: Conventional, Gas, 0.65 EF. Window-to-Floor Area Ratio: 0.07 Blower door test: Htg: 0.30 Clg: 0.30 ACHnat In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 10523 LAUREL RIDGE LN, CARMEL (AS DESIGNED), IN by JONES BUILDING GROUP exceeds the minimum requirements for the 2009 International Energy Conservation Code Building Features Ceiling Flat: R-38.0 Duct Leakage to Outside: 204.00 CFM @ 25 Pascals Sealed Attic: NA Total Duct Leakage: 264.00 CFM @ 25 Pascals Vaulted Ceiling: NA Infiltration: Htg: 5.00 Clg: 5.00 ACH50 Above Grade Walls: R-19.5 Window: U-Value: 0.310, SHGC: 0.300 Foundation Walls: R-0.0 Heating Fuel-fired air distribution, Natural gas, 92.1 AFUE. Exposed Floor: NA Cooling Air conditioner, Electric, 13.0 SEER. Slab: R-0.0 Edge, R-0.0 Under Water Heating Conventional, Natural gas, 0.65 EF, 75.0 Gal. Duct: NA 04-03-2017 The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in compliance with Chapter 4 based on Climate Zone 5A and with all mandatory requirements. Name: DEVIN SIELSCHOTT Signature: Organization: TSI ENERGY SOLUTIONS Date: April 03, 2017 The 2009 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( “ICC”). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software v15.3