Loading...
HomeMy WebLinkAbout02_2017-03-30 - Sun King Distillery - CDs - Structural DwgsA B INDCATES DEPRESSED OR RAISED EDGE OF SLAB INDCATES START OR END OF SLOPED SLAB INDCATES NON-SEISMIC BEAM-TO-COLUMN MOMENT CONNECTION INDCATES NON-SEISMIC BEAM-TO-GIRDER MOMENT CONNECTION INDCATES SEISMIC BEAM-TO-COLUMN MOMENT CONNECTION MCX INDCATES SPAN DIRECTION OF COMPOSITE FLOOR SLAB. REFER TO FRAMING PLANS FOR SLAB EXTENTS AND INFORMATION. INDCATES SPAN DIRECTION OF STEEL ROOF DECK. REFER TO FRAMING PLANS FOR ROOF DECK EXTENTS AND INFORMATION. TC TB INDCATES BEAM OR GIRDER RUNS OVER TOP OF COLUMN. REFER TO TYPICAL DETAILS FOR CONNECTION DETAILS. INDCATES COLUMN SUPPORTED BY BEAM OR GIRDER. REFER TO TYPICAL DETAILS FOR CONNECTION DETAILS. PLAN ANNOTATION SYMBOL KEY www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 1/4" = 1'-0"3/30/201710:51:09AMS001 GENERAL NOTES AND ABBREVIATIONS Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 1.IF THE DRAWINGS AND SPECIFICATIONS ARE IN CONFLICT, THE MORE STRINGENT RESTRICTIONS AND REQUIREMENTS SHALL GOVERN. 2.PLAN NOTES, DETAILS AND SECTIONS SHALL TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES. TYPICAL DETAILS AND SECTIONS NOT CUT ON THE PLANS SHALL APPLY UNLESS NOTED OTHERWISE. 3.REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS NOT SHOWN ON THE STRUCTURAL DRAWINGS. 4.CONTRACTORS ARE REQUIRED TO COORDINATE THEIR RESPECTIVE WORK WITH ALL OTHER DISCIPLINES TO AVOID ANY CONFLICTS DURING CONSTRUCTION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE THE STRUCTURAL DRAWINGS WITH ALL OTHER CONSTRUCTION DOCUMENTS. 5.LOCATION, SIZES AND QUANTITY OF ALL OPENINGS MAY NOT BE COMPLETELY INDICATED ON THE STRUCTURAL DRAWINGS. CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL OPENINGS WITH ALL OTHER DISCIPLINES PRIOR TO ANY FABRICATION. 6.CONTRACTORS ARE REQUIRED TO VERIFY EXISTING CONDITIONS PRIOR TO ANY FABRICATION OR CONSTRUCTION. IF EXISTING CONDITIONS ARE DIFFERENT THAN SHOWN, NOTIFY A/E IMMEDIATELY FOR MODIFICATIONS TO THE DRAWINGS. 7.THE CONTRACT DOCUMENTS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT LIMITED TO, BRACING, SHORING, UNDERPINNING, ETC. THE A/E IS NOT RESPONSIBLE FOR THE CONTRACTOR'S MEANS, METHODS, TECHNIQUES, SEQUENCES OR SAFETY PROCEDURES DURING CONSTRUCTION. GENERAL NOTES: GENERAL INFORMATION 1.WHERE LINTELS ARE NOT SPECIFICALLY SHOWN OR NOTED ON THE STRUCTURAL OR ARCHITECTURAL DRAWINGS, PROVIDE THE FOLLOWING LINTELS OVER ALL OPENINGS AND RECESSES IN BOTH INTERIOR AND EXTERIOR WALLS. PROVIDE 8" MINIMUM BEARING U.N.O: - PRECAST LINTELS: PROVIDE 4", 6" OR A COMBINATION FOR OPENINGS UP TO 10'-0" WIDE. - LOOSE LINTEL ANGLES FOR BRICK/STONE VENEER: OPENINGS UP TO 5'-0" ........................:USE L5x5x5/16" OPENINGS 5'-0" TO 7'-0" ......................:USE L6x4x5/16" (LLV) OPENINGS 7'-0" TO 10'-0" ....................:USE L7x4x3/8" (LLV) - ALL LOOSE LINTEL AND CONTINUOUS RELIEF ANGLES SHALL BE HOT-DIPPED GALVANIZED LINTELS 1.ALL CONCRETE, UNLESS OTHERWISE NOTED IN SCHEDULES OR DETAILS, SHALL HAVE A MINIMUM 28 DAY CONCRETE COMPRESSIVE STRENGTH OF 4000 PSI. ALL CONCRETE SHALL BE NORMAL WEIGHT (145 PCF),EXCEPT, ALL ELEVATED CONCRETE SLABS OVER METAL DECK SHALL BE LIGHTWEIGHT (110 PCF) U.N.O. ON PLANS. 2.ALL CONCRETE EXPOSED TO THE WEATHER SHALL BE AIR-ENTRAINED. FOR SURFACE FINISHES AND OTHER REQUIREMENTS, REFER TO THE CONCRETE SPECIFICATIONS. 3.DETAILS OF FABRICATION OF REINFORCEMENT, HANDLING AND PLACEMENT OF THE CONCRETE, CONSTRUCTION OF FORMS AND PLACEMENT OF REINFORCEMENT, NOT OTHERWISE COVERED BY THE PLANS AND SPECIFICATIONS, SHALL COMPLY WITH THE LATEST ADDITION OF THE A.C.I. CODE AND C.R.S.I. REQUIREMENTS. 4.PROVIDE 3/4" CHAMFERS ON ALL EXPOSED EDGES OF CONCRETE AND THE EXPOSED CORNERS OF BEAMS, GIRDERS AND COLUMNS UNLESS OTHERWISE SHOWN OR NOTED. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL DETAILS. 5.ALL MISCELLANEOUS ITEMS TO BE INSTALLED IN ANY CONCRETE WORK, SUCH AS PIPES, ELECTRICAL CONDUITS, DOVETAIL ANCHOR SLOTS, REGLETS, ETC., SHALL BE PROPERLY LOCATED, INSTALLED AND CHECKED BY THE G.C. PRIOR TO PLACEMENT OF CONCRETE. REFER TO ARCHITECTURAL AND MEP DRAWINGS FOR THE EXACT EXTENT AND LOCATION OF THESE ITEMS THAT ARE NOT SPECIFICALLY SHOWN ON THE STRUCTURAL DRAWINGS. 6.PROVIDE SLEEVES FOR ALL PIPE AND CONDUIT PENETRATIONS IN FOUNDATION WALLS, GRADE BEAMS, WALL FOOTINGS AND TRENCH FOOTINGS TO TOTALLY SEPARATE THE PIPES FROM THE CONCRETE. REFER TO TYPICAL DETAILS. 7.THE CONTRACTOR SHALL CONSULT WITH THE ENGINEER BEFORE STARTING CONCRETE WORK TO ESTABLISH A SATISFACTORY PLACING SCHEDULE AND TO DETERMINE THE LOCATION OF CONSTRUCTION JOINTS SO AS TO MINIMIZE THE EFFECTS OF SHRINKAGE. NO CONCRETE POUR SHALL EXCEED THE FOLLOWING DIMENSION IN ANY DIRECTION: - NORMAL WEIGHT CONCRETE .............................................:80 LINEAL FEET - LIGHTWEIGHT CONCRETE ...................................................:60 LINEAL FEET - LENGTH TO WIDTH RATIO SHALL BE LESS THAN OR EQUAL TO 2 8.NO HORIZONTAL CONSTRUCTION JOINTS SHALL BE MADE IN CONCRETE WALLS, FOOTINGS, BEAMS OR SLABS UNLESS SHOWN OR NOTED IN THE CONTRACT DRAWINGS. VERTICAL JOINTS ARE PERMITTED IN CONCRETE SLABS, WALLS, WALL FOOTINGS, TRENCH FOOTINGS AND GRADE BEAMS. REFER TO TYPICAL DETAILS. 9.ALL CONSTRUCTION JOINTS IN CONCRETE WALLS, FOOTINGS, BEAMS OR SLABS SHALL BE PROVIDED WITH A KEYWAY. THE SURFACE OF THE CONCRETE SHALL BE THOROUGHLY CLEANED AND ALL LATIANCE REMOVED. IN ADDITION, THE JOINT SHALL BE THOROUGHLY WETTED AND SLUSHED WITH A COAT OF CEMENT GROUT OR A BONDING AGENT IMMEDIATELY BEFORE PLACING CONCRETE. 10.CONTROL JOINTS, IF NOT SHOWN ON DRAWINGS, SHALL BE PROVIDED IN ALL SLABS-ON-GRADE THAT ARE EXPOSED OR THAT SUPPORT BRITTLE FINISHES SUCH AS CERAMIC TILE OR TERAZZO. JOINTS SHALL BE LOCATED ON EACH COLUMN LINE AND NOT TO EXCEED 15' IN EITHER DIRECTION U.N.O. SEE TYPICAL SLAB-ON-GRADE DETAILS. 11.THE SAW CUTTING OF CONTROL JOINTS IN A SLAB-ON-GRADE MAY BEGIN WHEN THE CUTTING ACTION WILL NOTTEAR, ABRADE, OR OTHERWISE DAMAGE THE SURFACE AND BEFORE THE CONCRETE DEVELOPS RANDOM SHRINKAGE CRACKING. SAW CUTTING MAY BEGIN AND FINISH WITHIN 4 TO 12 HOURS AFTER SURFACE FINISHING ISCOMPLETE. 12.REFER TO CONCRETE SPECIFICATIONS FOR FLOOR FLATNESS REQUIREMENTS AT THE SLAB-ON-GRADE ANDELEVATED CONCRETE SLAB TYP. 13.MAINTAIN A MAXIMUM SLOPE OF 1 VERTICAL TO 2 HORIZONTAL BETWEEN BEARING ELEVATIONS OF ADJACENT FOOTINGS TO AVOID UNDERMINING FOUNDATIONS UNLESS NOTED OTHERWISE IN PLANS. 14.SET ANCHOR BOLTS WITH 3/4" THICK PLYWOOD TEMPLATES OR 1/4" THICK STEEL PLATE TEMPLATES AND BRACE AGAINST DISPLACEMENT. CONCRETE STRUCTURAL STEEL 1.BUILDING CODE: THE 2012 INTERNATIONAL BUILDING CODE (IBC) W/ 2014 INDIANA BUILDING CODE AMENDMENTS. 2.DESIGN CODES: - AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), 360-10 SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS - AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), 341-10 SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS - AMERICAN IRON AND STEEL INSTITUTE (AISI), NAS-07 NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS INCLUDING 2010 SUPPLEMENT - AMERICAN CONCRETE INSTITUTE (ACI), 318-11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE - AMERICAN CONCRETE INSTITUTE (ACI), 530-11 BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES & 530.1-11 SPECIFICATIONS FOR MASONRY STRUCTURES - AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE), 7-10 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES - ALL OTHER APPLICABLE CODES AS REFERENCED IN CHAPTER 35 OF THE 2012 IBC 3.DESIGN LOAD CRITERIA: GRAVITY LOADS: DEAD LOAD OF STRUCTURE ..................................................:ACTUAL ADDITIONAL DEAD LOAD ALLOWANCES: - SUSPENDED M/E/P TYPICAL ...............................................:15 PSF - SUSPENDED CEILINGS/FLOORING .....................................:3 PSF - ADD'L CONCRETE TO MAINTAIN FLOOR FLATNESS ..............:8 PSF - ROOFING MATERIAL & INSULATION ....................................:15 PSF - MECHANICAL EQUIPMENT (OUTSIDE MECH ROOM) ..............:AS NOTED ON PLANS LIVE LOADS: - ELEVATED FLOOR LIVE LOAD .............................................:100 PSF SNOW LOADS: - GROUND SNOW LOAD, Pg ..................................................:20 PSF - SNOW EXPOSURE FACTOR .................................................:1.0 - THERMAL FACTOR, Ct .........................................................:1.0 AT RESTAURANT 1.2 AT PATIO - SNOW IMPORTANCE FACTOR, Is .........................................:1.0 - FLAT ROOF SNOW LOAD, Pf ................................................:25 PSF - SNOW DRIFTS ARE CALCULATED PER ASCE 7-10 AND SUPERIMPOSED ON FLAT ROOF SNOW LOADS AS APPLICABLE AT LOWER ROOFS WIND LOAD CRITERIA: - BASIC WIND SPEED .............................................................:115 MPH (3 SECOND GUST) - WIND EXPOSURE CATEGORY ...............................................:B - BUILDING OCCUPANCY CATEGORY .....................................:II - INTERNAL PRESSURE COEFFICIENT, GCpi ...........................:+/- 0.18 - DESIGN WIND PRESSURE FOR COMPONENTS & CLADDING:35 PSF (LOAD GIVEN IS AT THE ULTIMATE LEVEL PER ASCE 7-10) SEISMIC LOAD CRITERIA: - BUILDING OCCUPANCY CATEGORY ......................................:II - SEISMIC IMPORTANCE FACTOR .............................................:1.0 - SITE CLASS ...........................................................................:C - MAPPED SPECTRAL RESPONSE ACCELERATION ....................:Ss = 0.146, S1 = 0.081 - DESIGN SPECTRAL RESPONSE ACCELERATION .....................:Sds = 0.117, Sd1 = 0.092 - SEISMIC DESIGN CATEGORY .................................................:B - OVERALL BUILDING HEIGHT ...................................................:31 FT - LATERAL FORCE RESISTING SYSTEM .....................................:ORDINARY STEEL MOMENT FRAMES, NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE - RESPONSE MODIFICATION COEFFICIENT, R ...........................:3 - OVERSTRENGTH FACTOR, O0 .................................................:3 - DEFLECTION AMPLIFICATION FACTOR, Cd ..............................:3 - SEISMIC RESPONSE COEFFICIENT, Cs ...................................:0.039 - ANALYSIS PROCEDURE USED ................................................:EQUIVALENT LATERAL FORCE 4.PROVISION FOR FUTURE EXPANSION IS NOTED AS FOLLOWS:NONE DESIGN 1.ALL MASONRY WORK SHALL CONFORM TO THE REQUIREMENTS OF THE LOCAL BUILDING CODE, BUILDINGCODE REQUIREMENTS OF MASONRY STRUCTURES (ACI 530-11/ ASCE 5-11/TMS 402-11) AND SPECIFICATIONS FOR MASONRY STRUCTURES (ACS 530.1-11/ASCE 6-11/TMS 602-11). 2.ALL MASONRY WORK SHALL BE SUBJECTED TO CONTROLLED INSPECTION. 3.ALL CONCRETE MASONRY SHALL CONFORM WITH ASTM C90 HOLLOW LOAD BEARING UNITS WITH A MINIMUM COMPRESSIVE STRENGTH OF 1900 PSI ON THE NET SECTION. ALL CMU SHALL BE LIGHTWEIGHT UNLESS NOTED OTHERWISE. 4.ALL MORTAR SHALL CONFORM WITH ASTM C270 (REFERENCE SPECIFICATIONS). MORTAR SHALL BE PLACED IN ALL CONTACT AREAS, INCLUDING HORIZONTAL CONTACT AREAS AND VERTICAL SIDES. 5.ALL GROUT SHALL CONFORM WITH ASTM C476 AND HAVE AN AVERAGE COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS (REFERENCE SPECIFICATION). CONCRETE SHALL NOT BE USED IN LIEU OF MASONRY GROUT. 6.UNLESS OTHERWISE NOTED, CENTER ALL VERTICAL REINFORCING IN CMU CORE AND HOLD IN POSITION WITH CAGING DEVICES. 7.THE MINIMUM LENGTH OF LAP FOR REINFORCING IN MASONRY WALLS UNLESS OTHERWISE NOTED SHALL BE 48 BAR DIAMETERS. 8.REFERENCE THE SPECIFICATIONS FOR HORIZONTAL JOINT REINFORCING SIZE AND SPACING. 9.ALL BOND BEAMS SHALL BE CONTINUOUS AND SHALL BE FILLED WITH GROUT AND CONTINUOUS REINFORCEMENT AS SHOWN ON THE DRAWINGS OR AS FOLLOWS: - 6" WIDE BOND BEAM ....................................:(1) #5 REBAR - 8" AND 10" WIDE BOND BEAM .....................:(2) #5 REBAR - 12" WIDE BOND BEAM ..................................:(2) #6 REBAR 10.DISCONTINUE REINFORCING STEEL AT CONTROL JOINTS AND PROVIDE REINFORCEMENT AT CORNERS AND INTERSECTIONS AS SHOWN IN THE TYPICAL DETAILS. 11.GROUT SHALL BE PLACED IN THE VERTICAL CORES OF THE MASONRY UNITS UTILIZING THE LOW LIFT GROUTING METHOD SET FORTH IN NCMA-TEK 23A: A.GROUT SHALL COMPLY WITH ASTM C476 (MORTAR OR CONCRETE SHALL NOT BE USED T0 FILL CMU CORES.) REFERENCE SPECIFICATION. B.WEBS ADJACENT TO CORES TO BE GROUTED SHALL BE MORTARED. MORTAR SHALL BE STRUCK FLUSH WITH THE INSIDE FACE OF CORES TO BE GROUTED. CORES TO BE GROUTED SHALL BE CLEARED OF ALL MORTAR DROPPINGS AND OTHER DEBRIS PRIOR TO GROUTING. C.THE MAXIMUM HEIGHT OF A GROUT SHALL BE 4 FEET. D.STEP GROUT POURS 1-1/2 INCHES BELOW THE UPPERMOST PORTION OF THE CAVITY BEING FILLED TO PROVIDE A KEY FOR THE NEXT LIFT OR POUR. E.CONSOLIDATE GROUT BY VIBRATING TWICE WITH A MECHANICAL VIBRATOR EACH LIFT. ONCE IMMEDIATELY AFTER POUR AND ONCE APPROXIMATELY 30 MINUTES AFTER GROUT IS INSTALLED. F.ALL REINFORCING STEEL SHALL BE INSPECTED IN PLACE BEFORE GROUTING AND THERE SHALL BE CONTINUOUS INSPECTION DURING THE GROUTING OPERATION. 12.REINFORCE AND GROUT CORES AT EACH JAMB OF MASONRY OPENINGS AS FOLLOWS: - UP TO 9'-0" OPENING ....................................:(1) #6 REBAR - 9'-0" TO 16'-0" OPENING ................................:(2) #6 REBAR 13.FOR BOND BEAM LINTEL REINFORCEMENT REQUIREMENTS, SEE TYPICAL DETAILS. REINFORCED MASONRY 1.ALL METAL DECK MATERIAL, FABRICATION, AND INSTALLATION SHALL CONFORM TO THE CURRENT EDITION OF THE STEEL DECK INSTITUTE (SDI) "SPECIFICATIONS AND COMMENTARY" AND "CODE OF RECOMMENDED STANDARD PRACTICE". 2.COMPOSITE FLOOR DECK TO BE GALVANIZED AND MEET OR EXCEED LOAD CAPACITIES OF VULCRAFT "VLI SERIES" COMPOSITE STEEL FLOOR DECK AND CONFORM TO ALL SDI CRITERIA AND RECOMMENDATIONS. REFER TO STRUCTURAL PLANS FOR COMPOSITE DECK SIZE, GAUGE, ORIENTATION AND LOCATION. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. 3.PROVIDE ALL REQUIRED ACCESSORIES FOR A COMPLETE JOB INCLUDING DECK SUPPORT ANGLES AT COLUMNS AND DECK SPAN CHANGES, COVER PLATES, CLOSURES AND SUMP PANS. 4.DECK SHALL BE PROVIDED IN A MINIMUM OF 3 SPAN LENGTHS WHERE POSSIBLE. 5.DECK SHALL BE FASTENED TO SUPPORTING MEMBERS WITH SHEAR CONNECTORS OR 3/4" MINIMUM DIAMETER FUSION WELDS AT 12" O.C. MAXIMUM SPACING. FASTEN SIDELAPS AT INTERVALSNOT TO EXCEED 2'-0" O.C. MAXIMUM. 6.SCREEDS SHALL BE SET TAKING INTO ACCOUNT THE DEAD LOAD DEFLECTIONS NOTED ON THE PLANS AND ANY CAMBER IN THE BEAMS IN ORDER TO ACHIEVE A LEVEL FLOOR. SET BEAMS AND GIRDERS WITH CAMBER UP. 7.THE SEQUENCE AND METHOD OF POURING THE FLOORS SHALL BE SUBMITTED TO THE A/E PRIOR TO STARTING ANY CONCRETE OPERATIONS. IN GENERAL, CONCRETE POURS SHOULD BE MADE ACROSS THE ENTIRE WIDTHOF A FLOOR IN A DIRECTION PARALLEL TO THE GIRDERS. ANY SINGLE POUR SHOULD BE STOPPED AT A COLUMN LINE. 8.SHEAR CONNECTORS SHALL BE 3/4"ø x 4 1/2" LONG HEADED STUDS. SEE PLANS FOR LOCATION. 9.CONTRACTOR SHALL SUBMIT SHOP DRAWINGS INDICATING SHEAR STUD LOCATIONS ON EACH BEAM. 10.SHEAR STUDS SHALL BE LOCATED IN ACCORDANCE WITH THE LATEST AISC SPECIFICATIONS. 11.SHEAR STUD INSTALLATION SHALL BE TESTED BY THE TESTING INSPECTOR PER AWS SPECIFICATIONS AND APPROVED BEFORE ANY SLABS CAN BE POURED. THE ARCHITECT/ENGINEER MAY RANDOMLY TEST THE STUDS AND MAY REQUIRE ADDITIONAL WORK IF THE WORK IS DEEMED INADEQUATE. COMPOSITE METAL DECK 1.TYPICAL BUILDING FOUNDATION DESIGN BASED ON NET ALLOWABLE SOIL BEARING PRESSURE OF 2500 PSF FOR COLUMN SPREAD FOOTINGS AND 2000 PSF FOR CONTINUOUS WALL FOOTINGS. BUILDING FOUNDATIONS EXTENDING TO AT LEAST 9 FEET BELOW EXISTING GRADE MAY BE DESIGNED FOR 3500 PSF AT SPREAD FOOTINGS AND 2800 PSF AT CONTINUOUS WALL FOOTINGS. REFER TO GEOTECHNICAL REPORT NO. 15IN0457-0516 DATED MAY 31, 2016 BY ALT & WITZIG ENGINEERING, INC. SOIL BEARING PRESSURE TO BE FIELD VERIFIED BY A QUALIFIED SOILS ENGINEER PRIOR TO CONSTRUCTION. 2.THE SOILS REPORT REFERENCED ABOVE WAS SPEFICIALLY PREPARED FOR THE IMMEDIATELY ADJACENT ALLIED SOLUTIONS HEADQUARTERS. HOWEVER, TWO BORINGS WERE PERFORMED IN THE FOOTPRINT OF THE SUN KING DISTILLERY IN ANTICIPATION OF THIS PROJECT. TOM COFFEY WITH ALT & WITZIG CONFIRMED VIA TELEPHONE AND EMAIL ON DECEMBER 15, 2016 THAT THE SHALLOW FOUNDATION RECOMMENDATIONS IN THE ABOVE REFERENCED GEOTECHNICAL REPORT ARE APPROPRIATE FOR THE SUN KING FACILITY. 3.BUILDING FOUNDATION SHALL BE PLACED ON FIRM, UNDISTURBED NATURAL SOILS OR ON ENGINEERED FILL MATERIAL. FOR AREAS REQUIRING ENGINEERED FILL, THIS MATERIAL SHALL CONSIST OF CLEAN GRANULAR FILL COMPACTED AS NOTED IN THE EARTHWORK SPECIFICATIONS AND PLACED IN LIFTS AS RECOMMENDED BY THE SOILS ENGINEER ON SITE OR AS SHOWN IN THE GEOTECHNICAL REPORT. SOIL BEARING PRESSURE OF ENGINEERED FILL TO BE FIELD VERIFIED BY A THE SOILS ENGINEER ON SITE PRIOR TO CONSTRUCTION. 4.SUBBASE MATERIAL UNDER SLABS-ON-GRADE TO BE CLEAN GRANULAR FILL COMPACTED AS NOTED IN THE EARTHWORK SPECIFICATIONS AND THE GEOTECHNICAL REPORT. 5.BACKFILL AGAINST GRADE BEAMS AND FROST WALLS SHALL BE PLACED EVENLY ON BOTH SIDES. 6.UNDERCUTTING OF THE SOIL FOR FOUNDATION AND/OR PLACEMENT MAY BE REQUIRED AS NOTED IN THE GEOTECHNICAL REPORT. THE STRUCTURAL DRAWINGS MAY NOT INDICATE THE ENTIRE SCOPE OF UNDERCUTTING, FILL, BAD SOIL OR ROCK REMOVAL THAT MAY BE REQUIRED TO ATTAIN THE DESIGN SOIL BEARING PRESSURES. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ASSESS THE EXTENT OF EXCAVATION AND COMPACTION THAT MAY BE REQUIRED TO MEET THE DESIGN CRITERIA. 7.A REPORT CERTIFIED BY THE SOILS ENGINEER ON SITE SHALL BE FURNISHED TO THE A/E VERIFYING THAT ALL FOUNDATIONS WERE PLACED ON A MATERIAL CAPABLE OF SUSTAINING THE DESIGN BEARING PRESSURES. 8.IF DEWATERING IS REQUIRED, SUMPS SHALL NOT BE PLACED WITHIN THE FOUNDATION EXCAVATION. EARTHWORK/FOUNDATION NOTES 1.ALL METAL DECK MATERIAL, FABRICATION, AND INSTALLATION SHALL CONFORM TO THE CURRENTEDITION OF THE STEEL DECK INSTITUTE (SDI) "SPECIFICATIONS AND COMMENTARY" AND "CODE OF RECOMMENDED STANDARD PRACTICE". 2.ROOF DECK TO BE GALVANIZED AND MEET OR EXCEED LOAD CAPACITIES OF VULCRAFT "B SERIES" METAL ROOF DECK AND CONFORM TO ALL SDI CRITERIA AND RECOMMENDATIONS. REFER TO STRUCTURAL PLANS FOR METAL ROOF DECK SIZE, GAUGE, ORIENTATION AND LOCATION. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. 3.DECK SHALL BE PROVIDED IN A MINIMUM OF 3 SPAN LENGTHS WHERE POSSIBLE. 4.METAL ROOF DECK IS DESIGNED AS A HORIZONTAL DIAPHRAGM. ALL WELDS TO BE 5/8" PUDDLE WELDS. WELDING PATTERN SHALL BE 36/4 WITH #10 TEK SCREWS AT 24" O.C. AT SIDELAPS. 5/8" PUDDLE WELDS AROUND EDGES OF ROOF SHALL BE AT 24" O.C. 5.PROVIDE ALL REQUIRED ACCESSORIES FOR A COMPLETE JOB INCLUDING DECK SUPPORT ANGLES AT COLUMNS AND DECK SPAN CHANGES, COVER PLATES, CLOSURES AND SUMP PANS. 6.DO NOT SUSPEND LIGHT FIXTURES, DUCTS, BULKHEADS, OTHER UTILITIES, ETC., FROM THE STEEL ROOF DECK. METAL ROOF DECK 1.ALL REINFORCING STEEL SHALL BE DETAILED AND PLACED IN ACCORDANCE WITH THE LATEST ADDITION OF ACI 315, ACI 318, AND CRSI. 2.REINFORCEMENT SHALL HAVE DEFORMED SURFACES IN ACCORDANCE WITH ASTM A615 WITH MINIMUM YIELD STRENGTH OF 60,000 PSI. 3.WELDED WIRE FABRIC SHALL BE SMOOTH CONFORMING TO ASTM A185. 4.THE SHOP DRAWINGS FOR REINFORCING STEEL SHALL INCLUDE SCALE ELEVATIONS OF ALL CONCRETE WALLS. 5.PROVIDE CORNER BARS AT ALL WALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. 6.REINFORCING STEEL SHALL HAVE THE FOLLOWING CONCRETE PROTECTION (CLEAR COVER) UNLESS OTHERWISE NOTED: - SURFACES NOT FORMED AND IN CONTACT WITH SOIL .................:3" - FORMED SURFACES IN CONTACT WITH SOIL OR WEATHER .........:2" - BEAMS, GIRDERS AND COLUMNS ......................................................:1 1/2" - SLABS, WALLS AND JOISTS ................................................................:3/4" 7.PROVIDE 50 BAR DIA. LAP SPLICES FOR #6 REBAR AND SMALLER AND 62 BAR DIA. LAP SPLICES FOR #7 REBAR AND LARGER. TYPICAL U.N.O. 8.PROVIDE ADDITIONAL REINFORCING BARS AROUND ALL OPENINGS IN CONCRETE SLABS AND WALLS EQUAL TO THE AMOUNT INTERRUPTED BY THE OPENINGS (1/2 EA. SIDE TYPICAL). WHERE OPENINGS ARE SUCH THAT THE REINFORCING STEEL IS NOT INTERRUPTED, NO ADDITIONAL REINFORCING IS REQUIRED. REFER TO TYPICAL CONCRETE OPENING DETAIL. 9.OPENINGS THROUGH CONCRETE WALLS, SLABS OR OTHER STRUCTURAL ELEMENTS NOT DETAILED ON THE STRUCTURAL DRAWINGS MUST BE LOCATED AND SHOWN ON THE APPLICABLE REINFORCING STEEL SHOP DRAWINGS. THE FINAL LOCATION OF ALL OPENINGS MUST BE REVIEWED BY THE A/E BEFORE THE CONCRETE IS POURED. 10.THE WELDED WIRE FABRIC IN THE COMPOSITE ELEVATED SLAB SHALL BE SUPPORTED BY PLACING CONTINUOUS HEAVY BOLSTERS AT 2'-6" O.C. MAXIMUM OVER THE COMPOSITE METAL DECK. 11.THE WELDED WIRE FABRIC IN THE CONCRETE SLAB-ON-GRADE SHALL BE SUPPORTED BY CONTINUOUS #4 SUPPORT BARS AT 2'-6" O.C. MAXIMUM. THE #4 BARS SHALL BE TIED AND SUPPORTED BY CHAIRS (2 1/4" HIGH) AT 2'-6" O.C. MAXIMUM. 12.THE CONTRACTOR SHALL PROVIDE A UNIT COST TO SUPPLY, FABRICATE AND INSTALL 2 TONS OF REINFORCING STEEL IN ADDITION TO THAT SHOWN ON THE PLANS. THIS ADDITIONAL REINFORCING STEEL SHALL BE INSTALLED AT THE DIRECTION OF THE A/E. THE OWNER SHALL BE GIVEN A CREDIT AT THE CONTRACT UNIT PRICE FOR THE UNUSED PORTION. REINFORCING STEEL ADDL ADJ ALT APPRX ARCH B/ B/B BLDG BLK BLKG BM BOT BRDG BRG BTWN C C/C CIP CL CLR CMU COL COMP CONC CONN CONST CONT DBL DET DIA DIAG DIM(S) DL DWG(S) DWL(S) ECC EA EF EL ELEC ENGR E.O.D. E.O.S EQ EQUIP EW EXP EXST EXT F/F FIN FL FND FP FS FTG GA GALV GEN GR HK HORZ HP HT ID IF INFO INT INTRM JST(S) JT K KLF KSF LL LLH ADDITIONAL ADJACENT ALTERNATE APPROXIMATE ARCHITECT OR ARCHITECTURAL BOTTOM OF BACK TO BACK BUILDING BLOCK BLOCKING BEAM BOTTOM BRIDGING BEARING BETWEEN COMPRESSION CENTER TO CENTER CAST-IN-PLACE CENTER LINE CLEAR OR CLEARANCE CONCRETE MASONRY UNIT COLUMN COMPRESSION CONCRETE CONNECTION CONSTRUCTION(S) CONTINUOUS DOUBLE DETAIL DIAMETER DIAGONAL DIMENSION(S) DEAD LOAD DRAWING(S) DOWEL(S) ECCENTRICITY EACH EACH FACE ELEVATION ELECTRICAL ENGINEER EDGE OF DECK EDGE OF SLAB EQUAL EQUIPMENT EACH WAY EXPANSION EXISTING EXTERIOR FACE TO FACE FINISH(ED) FLOOR FOUNDATION FIREPROOF(ING) FAR SIDE FOOTING GAGE OR GAUGE GALVANIZED GENERAL GRADE HOOK HORIZONTAL HIGH POINT HEIGHT INSIDE DIAMETER INSIDE FACE INFORMATION INTERIOR INTERMEDIATE JOIST(S) JOINT KIPS (OR 1,000 POUNDS) KIP PER LINEAR FOOT KIP PER SQUARE FOOT LIVE LOAD LONG LEG HORIZONTAL LLV LONG LP LWC LWT M MATL MAX MC MECH MEZZ MFGR MID MIN MISC NIC NO NOM NS NTS NWC NWT O.C. O.D. O.F. O.H. OPNG(S) OPP PC PCY PERP PL PRCST PRLL PSF PSI PT RAD REF REINF REQD RD SCHED SDL SECT SF SHT SIM SOG SP SPEC(S) STD STL STRCT STRCTL SUPPTS SYM T T/ T&B TEMP TH T/FTG T/SLAB T/STEEL TYP UNO V VERT VIF W/ W/O WD WP WPFG WS WWF LONG LEG VERTICAL LONGITUDINAL LOW POINT LIGHTWEIGHT CONCRETE LIGHTWEIGHT MOMENT MATERIAL MAXIMUM MOMENT CONNECTION(S) MECHANICAL MEZZANINE MANUFACTURER MIDDLE MINIMUM MISCELLANEOUS NOT IN CONTRACT NUMBER NOMINAL NEAR SIDE NOT TO SCALE NORMAL WEIGHT CONCRETE NORMAL WEIGHT ON CENTER OUTSIDE DIAMETER OUTSIDE FACE OPPOSITE HAND OPENING(S) OPPOSITE PIECE POUNDS PER CUBIC YARD PERPENDICULAR PLATE PRECAST PARALLEL POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH POINT RADIUS REFERENCE REINFORCE(D) (ING) OR (MENT) REQUIRED ROOF DRAIN SCHEDULE(D) SUPERIMPOSED DEAD LOAD SECTION SQUARE FOOT (FEET) SHEET SIMILAR SLAB ON GRADE SPACE SPECIFICATION(S) STANDARD STEEL STRUCTURE STRUCTURAL SUPPORT(S) SYMMETRICAL TENSION TOP OF TOP AND BOTTOM TEMPERATURE THICK OR THICKNESS TOP OF FOOTING TOP OF SLAB TOP OF STEEL TYPICAL UNLESS NOTED OTHERWISE SHEAR VERTICAL VERIFY IN FIELD WITH WITHOUT WOOD WORK POINT WATERPROOFING WATERSTOP WELDED WIRE FABRIC Ø # (# #) (# #) (# # #) C# # C=# # GB# HSS# # L# # 2L# # P# PX# PXX# PG# S# W# # WT# # DIAMETER NUMBER, SIZE OR SECTION IDENTIFICATION NUMBER OF STUDS UNIFORMLY SPACE-TYP DETAIL (# #) NUMBER OF STUDS PER SECTION EQUALLY SPACED-TYP DETAIL DESIGN REACTION IN KIPS FOR FACTORED LOADS (LRFD) CHANNEL SECTION CAMBER IN INCHES GRADE BEAM HOLLOW STRUCTURAL SECTION SINGLE ANGLE SECTION DOUBLE ANGLE SECTION STRUCTURAL STEEL PIPE SECTION EXTRA STRONG STRUCTURAL STEEL PIPE SECTION DOUBLE-EXTRA STRONG STRUCTURAL STEEL PIPE SECTION PLATE GIRDER SPAN DIRECTION AND TYPE WIDE FLANGE SECTION TEE SECTION (CUT FROM A WIDE FLANGE SECTION) LBS POUNDS PLF POUNDS PER LINEAR FOOT ABBREVIATIONS AND SYMBOLS ABBREVIATIONS 1.DETAILS FOR DESIGN, FABRICATION AND ERECTION OF ALL STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH THE LATEST A.I.S.C. STANDARDS UNLESS OTHERWISE NOTED OR SPECIFIED. 2.ALL STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING U.N.O. ON THE STRUCTURAL DRAWINGS: WIDE FLANGE SHAPES ..................................:ASTM A572 OR ASTM A992 (Fy = 50 KSI) CHANNELS, ANGLES, PLATES, BARS .........:ASTM A36 (Fy = 36 KSI) RECTANGULAR TUBES (HSS) .......................:ASTM A500 GRADE B (Fy = 46 KSI) STRUCTURAL PIPE .........................................:ASTM A53 GRADE B (Fy = 35 KSI) 3.ALL STRUCTURAL BOLTS (INCLUDING WASHERS AND NUTS) SHALL CONFORM TO THE REQUIREMENTS OF ASTM A325OR A490. ALL BOLTS SHALL BE TIGHTENED TO THE SNUG TIGHT CONDITION U.N.O. BOLTING OF STRUCTURAL STEEL SHALL CONFORM TO THE PROVISIONS OF RCSC "SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A325 AND A490 BOLTS." 4.MINIMUM SIZE OF BOLTS SHALL BE 3/4" DIAMETER, AND EACH CONNECTION SHALL HAVE A MINIMUM OF 2 BOLTS WITHONE HARDENED WASHER PER BOLT. 5.ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 AS NOTED ON THE DRAWINGS. REFER TO TYPICAL DETAIL FOR SIZE AND LENGTH. 6.PERMANENT MACHINE BOLTS, USING AN APPROVED TYPE OF SELF ANCHORING HEX NUT, MAY BE USED FOR SUCH MINOR CONNECTIONS AS SHELF ANGLES, CLOSURES, ETC. 7.WELDING PROCEDURES SHALL CONFORM TO THE LATEST EDITION OF THE AMERICAN WELDING SOCIETY'S (AWS) STRUCTURAL WELDING CODES. ALL WELDING SHALL BE PERFORMED BY PREQUALIFIED WELDERS. 8.WELDED CONNECTIONS FOR STEEL MEETING ASTM A992 OR A572 SHALL BE MADE WITH E70XX LOW HYDROGEN ELECTRODES. OTHER WELDED CONNECTIONS TO BE MADE WITH REGULAR E70XX ELECTRODES. 9.WELDS NOT OTHERWISE NOTED ON DRAWINGS SHALL BE CONTINUOUS FILLET WELDS. THE MINIMUM SIZE SHALL BE 1/4" OR AS REQUIRED BY THE AISC SPECIFICATIONS, WHICHEVER IS LARGER. 10.MINIMUM THICKNESS OF ALL CONNECTION MATERIAL TO BE 5/16" UNLESS NOTED OTHERWISE. 11.UNLESS NOTED OTHERWISE, ALL SIMPLE BEAM SHEAR CONNECTIONS SHALL BE MADE USING DOUBLE ANGLE CONNECTIONS AND/OR SHEAR PLATE CONNECTIONS. CONNECTIONS SHALL BE HIGH STRENGTH BOLT BEARING TYPE WITH THREADED PARTS INCLUDED IN THE SHEAR PLANE. ALL CONNECTIONS, UNLESS FULLY DETAILED ON THE STRUCTURAL DRAWINGS, SHALL BE DESIGNED AND DETAILED BY THE STRUCTURAL STEEL FABRICATOR TO MEET BOTH AISC AND OSHA REQUIREMENTS. REFER TO TYPICAL DETAILS FOR TYPE OF SIMPLE BEAM CONNECTION AND MINIMUM BOLT REQUIREMENTS. 12.STEEL CONNECTIONS THAT ARE PART OF THE LATERAL FORCE RESISTING SYSTEM SHALL BE DESIGNED BY THE STEEL FABRICATOR'S CONNECTION ENGINEER FOR THE LOADS NOTED ON THE PLANS. CALCULATIONS AND SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A LICENSED PROFESSIONAL ENGINEER IN THE STATE OF INDIANA AND SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL. 13.PROVIDE TEMPORARY ERECTION BRACING OF THE STRUCTURE UNTIL ALL PERMANENT LATERAL SUPPORTS ARE IN PLACE. 14.STEEL COLUMNS BELOW GRADE SHALL PAINTED WITH 2 COATS OF ASPHALTIC PAINT AND ENCASED IN A MINIMUM OF 4" OF CONCRETE. 15.ALL EDGE ANGLES OR BENT PLATES SHALL BE FIELD APPLIED TO THE BEAMS WITH ±1/8" HORIZONTAL AND VERTICAL TOLERANCE TO FACILITATE OTHER INSTALLATIONS. 16.FIELD PAINT, WHERE APPLICABLE, ALL FIELD WELDS, ABRASIONS, RUST SPOTS AND FIELD BOLTS ON STRUCTURAL STEEL, JOISTS AND DECKING AFTER ERECTION. 17.ALL STEEL THAT IS EXPOSED TO THE ELEMENTS SHALL BE HOT-DIP GALVANIZED, TYPICAL. 18.ALL STEEL THAT IS TO REMAIN EXPOSED IN THE FINISHED STRUCTURE SHALL BE PAINTED PER ARCHITECTURAL DRAWINGS AND/OR SPECIFICATIONS. 19.THE CONTRACTOR SHALL PROVIDE A UNIT COST TO SUPPLY, FABRICATE AND INSTALL 2 TONS OF STRUCTURAL STEEL IN ADDITION TO THAT SHOWN ON THE PLANS. THIS ADDITIONAL STRUCTURAL STEEL SHALL BE INSTALLED AT THE DIRECTION OF THE A/E. THE OWNER SHALL BE GIVEN A CREDIT AT THE CONTRACT UNIT PRICE FOR THE UNUSED PORTION. 20.THE CONTRACTOR SHALL PROVIDE A UNIT COST TO SUPPLY, FABRICATE AND INSTALL 2 TONS OF MISCELLANEOUSSTEEL (ANGLES, PLATES, ETC.) IN ADDITION TO THAT SHOWN ON THE PLANS. THIS ADDITIONAL MISCELLANEOUS STEEL SHALL BE INSTALLED AT THE DIRECTION OF THE A/E. THE OWNER SHALL BE GIVEN A CREDIT AT THE CONTRACT UNIT PRICE FOR THE UNUSED PORTION. SYMBOLS 1.ALL STEEL JOISTS SHALL BE DESIGNED, FABRICATED AND ERECTED IN ACCORDANCE WITH THE LATEST SJI STANDARD SPECIFICATIONS UNLESS OTHERWISE NOTED. 2.JOIST BRIDGING SHALL CONFORM TO THE LATEST SJI SPECIFICATIONS AND/OR OSHA REQUIREMENTS. FIELD WELD BRIDGING AT ENDS AND INTERSECTIONS. ALL JOISTS FORTY (40) FEET AND LONGER REQUIRE A ROW OF BOLTED CROSS BRIDGING TO BE IN PLACE BEFORE SLAKENING OF HOISTING LINES. 3.ALL JOISTS SHALL BE PROPERLY ANCHORED AT BEARINGS BY EITHER BOLTING OR FIELD WELDING PER TYPICAL DETAILS. 4.JOIST BRIDGING AND CONNECTIONS SHALL BE COMPLETELY INSTALLED PRIOR TO PLACING ANY CONSTRUCTION LOADS ON THE JOISTS. CONSTRUCTION LOADING SHALL NOT EXCEED THE JOIST DESIGN LOADS. 5.ALL ROOF JOISTS SHALL BE DESIGNED FOR A NET WIND UPLIFT OF 10 PSF TYPICAL U.N.O. PROVIDE ADDITIONAL CONTINUOUS HORIZONTAL BOTTOM CHORD BRIDGING AS REQUIRED TO RESIST WIND UPLIFT. JOIST FABRICATOR MAY TAKE A 1/3 ALLOWABLE STRESS INCREASE FOR WIND LOADING DESIGN PER SJI SPECIFICATIONS. 6.ALL JOISTS SHALL BE SHOP PAINTED IN ACCORDANCE WITH SJI REQUIREMENTS. 7.THE JOIST MANUFACTURER SHALL SUBMIT CALCULATIONS FOR ALL SPECIAL JOISTS TO THE A/E FOR APPROVAL PRIOR TO FABRICATION. THESES CALCULATIONS SHALL BEAR THE SIGNED AND DATED SEAL OF A PROFESSIONAL ENGINEER REGISTERED IN THE STATE WHERE PROJECT IS LOCATED. 8.THE JOIST MANUFACTURER SHALL BE A SJI CERTIFIED SHOP AND MAINTAIN APPROVED FABRICATION PROCEDURES AS REQUIRED PER SJI REQUIREMENTS. 9.JOISTS AT COLUMN CENTERLINES SHALL HAVE EXTENDED BOTTOM CHORD CONNECTIONS. DO NOT CONNECT BOTTOM CHORD EXTENSIONS UNTIL ALL GRAVITY DEAD LOADS ARE IN PLACE. STEEL JOIST HWS HEADED WELDED STUD No.Description Date C D B 1 1 2 3 3 4 AA 5 5 6 6 E 1.2 D.8 1.4 2.4 2.3 3.7 A.9 C.3 C.5 HSS4X4X3/8 HSS5X5X3/8 HSS7X7X1/2 HSS7X7X5/8 HSS5X5X5/16 HSS10X10X1/2HSS10X10X5/8HSS10X10X5/8 HSS10X10X1/2 HSS10X8X1/2 HSS6X6X3/8 HSS6X6X3/8 HSS10X10X1/2 HSS10X10X5/8 HSS10X10X5/8 HSS10X10X5/8 HSS10X10X5/8 HSS10X10X1/2 HSS10X10X5/8 HSS7X7X5/8 HSS10X10X1/2 HSS5X5X1/2 HSS7X7X5/8 HSS5X5X3/8 HSS4X4X1/4 HSS4X4X1/4 124' - 10"78'-8"77'-4"22'-0"21'-10"13'-6"12'-6"7'-6"15' - 6" 124' - 10" 34' - 8"19' - 5"30' - 5"24' - 10"30'-111/4"20'-103/4"26'-10"24' - 8"25' - 2"24' - 10"15' - 0"12' - 6"12' - 6"8' - 8"1' - 6" 5' - 3"8'-0"5'-6"111/4"1'-4"F4 FB FC FE FA F8 F11 F10 F8 F6 F4 F5 F9 F11 F10 F10 F8 F6F7F7 F8 F5F6F4 F4 F3 T/FTG (90'-0") T/FTG (90'-0") T/FTG (90'-0") T/FTG (90'-0") T/FTG (90'-0") T/FTG (90'-0") T/FTG (90'-0")T/FTG(90'-0")T/FTG(92'-4")FOOTING STEP PER 8/S300 T/FTG (97'-0") FOOTING STEPS PER 8/S300 T/FTG (97'-0") T/FTG (95'-8") T/FTG (95'-8") T/FTG (92'-4") T/FTG (92'-4") T/FTG (90'-0")FOOTINGSTEPSPER8/S300T/FTG (96'-0") 4" SLAB ON GRADE SEE NOTE 66" SLAB ON GRADE SEE NOTE 9 6" SLAB ON GRADE SEE NOTE 18 S250 1 SOUTH FRAMING ELEVATION 8"SLABONGRADESEENOTE128"SLABONGRADESEENOTE129 S210 (SIM.) 10 S210 3 S211 (SIM.) 3 S211 6 S210 (SIM.) 6 S210 1 S210 9 S210 2 S210 12 S210 (TYP.) 1 S210 5 S210 1 S210 5 S210 (SIM.) S251 1 SOUTH PATIO FRAMING ELEVATION S251 2WESTPATIO FRAMINGELEVATIONFD FD FD FDFD FD FDFDFDFD FDFD FDFD FD 5'-77/8"SEE NOTE 11 SEE NOTE 11 T/FTG (95'-8")4'-8"FD 1' - 8"1'-8"13' - 5 1/2" 1' - 10"31/4"2'-87/8"1'-6"3'-0"11' - 2 1/2"4'-61/4"4'-71/4"11 S210 (TYP.) HSS6X4X5/16 HSS6X4X5/16 5' - 7 5/8" 6' - 0"2' - 1 1/4"53/4"7'-9"1'-10"8'-1"10' - 6 1/2"10'-7"1 S211 (TYP.) BP2/AR2 PG PJ PK BP3/AR3 BP9/AR4 BP9/AR4 BP3/AR3 PK PG PA BP6/AR5BP6/AR8BP7/AR8 BP7/AR8 BP5/AR6 PB BP1/AR1 BP1/AR1 PB BP7/AR7 BP6/AR7 BP6/AR7 BP6/AR9 PAPE BP7/AR5 BP2/AR2 BP2/AR2 BP3/AR3 BP4/AR4 BP3/AR3 BP7/AR5 BP9/AR4 BP7/AR9 BP6/AR9 PH PH PH PHPF PC PD PA PC T/FTG (92'-4") 8" SLAB ON GRADE SEE NOTE 12 LIMIT OF 8" SLAB LIMIT OF 8" SLAB LIMIT OF 6" SLAB LIMIT OF 6" SLAB LIMIT OF 6" SLAB 2 S211 YARD DRAINS, SEE NOTE 13 SEE NOTE 15 SEE NOTE 14 3 S211 11 S210 (TYP.) 10' - 1" 9 S300 9 S300 9 S300 FD PL (SIM.)(AT DOORS) 9 S3003'-4"2'-47/8"3'-4"3' - 9 1/4"4'-113/4"3'-4"1'-4"9'-41/4"1'-41/4"3 S210 9 S300 1 S210 9 1/4"9' - 3 3/8"7'-81/4"HSS5X5X1/4HSS5X5X1/4 BP3/AR3 F3 F3 T/FTG (98'-0")BP3/AR3 T/FTG (95'-0") PHPH 8" EXTERIOR SLAB SEE NOTE 16 2' - 6 3/4"3'-0"6x6 PRESSURE TREATED LUMBER COLUMN (TYP. OF 7) HSS6X6X3/8 HSS6X6X3/8 BP1/AR1 BP1/AR1 24" DIA. PIER PER 8/S210 (TYP. OF 6) 3' - 3 3/4"5' - 11"5' - 11"5' - 11"5' - 11"5' - 11" 6 1/4"EOS 1'-13/4"61/4"5'-7"105/8"41/4"3' - 8 5/8" 5 1/4" 24" DIA. PIER PER 4/S211 36" DIA. PIER PER 5/S211 6" SLAB ON GRADE SEE NOTE 9 4 S210 4 S210 FD 51/2"FD FD 2' - 5 1/8"13' - 0"5'-2"3'-2"SEE NOTE 17 www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 1/8" = 1'-0"3/30/201710:51:11AMS110 FOUNDATION PLAN Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 1/8" = 1'-0"S110 1 FOUNDATION PLAN COLUMN FOUNDATION SCHEDULE Type ANBP Geometry Bottom Rienforcing Top Reinforcing CommentsLengthWidthThicknessBott Long Bott Short Top Long Top Short F3 2.5 3' - 0"3' - 0"1' - 0"(4)-#4 (4)-#4 (4)-#4 (4)-#4 F4 2.5 4' - 0"4' - 0"1' - 0"(6)-#4 (6)-#4 F5 2.5 5' - 0"5' - 0"1' - 0"(7)-#4 (7)-#4 F6 2.5 6' - 0"6' - 0"1' - 3"(7)-#5 (7)-#5 (5)-#4 (5)-#4 F7 2.5 7' - 0"7' - 0"1' - 3"(8)-#5 (8)-#5 F8 2.5 8' - 0"8' - 0"1' - 3"(7)-#6 (7)-#6 F9 2.5 9' - 0"9' - 0"1' - 3"(8)-#6 (8)-#6 F10 2.5 10' - 0"10' - 0"1' - 6"(9)-#6 (9)-#6 F11 2.5 11' - 0"11' - 0"1' - 9"(9)-#7 (9)-#7 FA 2.5 6' - 0"4' - 8"1' - 0"(7)-#4 (12)-#4 FB 2.5 5' - 11"8' - 6"1' - 0"(8)-#4 (17)-#4 FC 2.5 7' - 2"11' - 0"1' - 0"(13)-#4 (16)-#4 (10)-#4 (6)-#4 FE 2.5 7' - 8"12' - 0"1' - 0"(19)-#4 (15)-#4 (6)-#4 (10)-#4 PLAN NOTES: 1.USGS DATUM 828.83 = FIRST FLOOR SLAB ELEVATION (100'-0"). 2.REFER TO DRAWING S001 FOR GENERAL NOTES, ABBREVIATIONS AND PLAN ANNOTATION SYMBOL KEY. 3.REFER TO DRAWING S300 FOR TYPICAL FOUNDATION DETAILS. 4.REFER TO DRAWING S305 FOR TYPICAL SLAB ON GRADE DETAILS. 5.REFER TO DRAWING S501 FOR TYPICAL STEEL COLUMN, BASE PLATE AND ANCHOR ROD DETAILS. 6.THE SLAB ON GRADE SHALL BE 4" THICK TYPICAL U.N.O. POUR SLAB OVER VAPOR RETARDER ON 6" OF WASHED GRANULAR FILL OVER COMPACTED STRUCTURAL FILL. REINFORCE SLAB WITH 6x6-W2.1xW2.1 WELDED WIRE REINFORCING IN SHEET FORM. TOP OF SLAB SHALL BE AT ELEVATION 100'-0" U.N.O. REFER TO PROJECT SOILS REPORT REFERENCED ON DRAWING S001 FOR ADDITIONAL INFORMATION. 7.THE TOP OF ALL INTERIOR FOOTINGS SHALL BE AT ELEVATION (99'-4") U.N.O. THE TOP OF ALL EXTERIOR FOOTINGS SHALL BE AT ELEVATION (97'-0") U.N.O. 8.THE GC SHALL COORDINATE THE SIZE AND LOCATIONS OF ALL OPENINGS IN WALLS, SLABS, ETC. WITH THE VARIOUS TRADES. 9.THE SLAB ON GRADE SHALL BE 6" THICK WHERE NOTED. POUR SLAB OVER VAPOR RETARDER ON 6" OF WASHED GRANULAR FILL OVER COMPACTED STRUCTURAL FILL. REINFORCE SLAB WITH 6x6-W2.9xW2.9 WELDED WIRE REINFORCING IN SHEET FORM. TOP OF SLAB SHALL BE AT ELEVATION 100'-0" U.N.O. REFER TO PROJECT SOILS REPORT REFERENCED ON DRAWING S001 FOR ADDITIONAL INFORMATION. SLOPE TO DRAINS AS REQUIRED. 10.O FD DENOTES A FLOOR DRAIN. SLAB SHALL BE SLOPED LOCALLY AROUND FLOOR DRAINS TO PROVIDE APPROPRIATE DRAINAGE. 11.THICKEN SLAB AT BASE OF STAIR STRINGERS PER DETAIL 9/S305. EXTEND THICKENED SLAB 12" BEYOND EDGE OF STAIR. 12.THE SLAB ON GRADE SHALL BE 8" THICK WHERE NOTED. POUR SLAB OVER VAPOR RETARDER ON 6" OF WASHED GRANULAR FILL OVER COMPACTED STRUCTURAL FILL. REINFORCE SLAB WITH #6@12" O.C. PERPENDICULAR TO FOUNDATION WALL AND #4@13" O.C. PARALLEL TO WALL AT BOTTOM OF SLAB AND 6x6-W2.1xW2.1 WELDED WIRE REINFORCING IN SHEET FORM AT TOP OF SLAB. TOP OF SLAB SHALL BE AT ELEVATION 100'-0" U.N.O. REFER TO PROJECT SOILS REPORT REFERENCED ON DRAWING S001 FOR ADDITIONAL INFORMATION. 13.SLOPE DOCK SLAB TO YARD DRAINS AS REQUIRED. COORDINATE WITH PLUMBING FOR FINAL LOACTIONS. 14.GREASE INTERCEPTOR BELOW DOCK SLAB. REFER TO PLUMBING DRAWINGS FOR LOCATION. 15.SEE PLUMBING DRAWINGS AND SPECIFICATIONS FOR SIZE AND LOCATION OF STAINLESS STEEL TRENCH DRAIN. 16.THE PATIO SLAB SHALL BE 8" THICK TYPICAL. POUR SLAB OVER 4" OF WASHED GRANULAR FILL OVER COMPACTED STRUCTURAL FILL. REINFORCE SLAB WITH #6@12" O.C. PERPENDICULAR TO FOUNDATION WALL AND #4@13" O.C. PARALLEL TO WALL AT BOTTOM OF SLAB AND 6x6-W2.1xW2.1 WELDED WIRE REINFORCING IN SHEET FORM AT TOP OF SLAB. ALL PATIO SLAB REINFORCING SHALL BE EPOXY COATED. TOP OF SLAB SHALL SLOPE FROM ELEVATION 100'-0" AT THE BRICK FACE TO MEET GRADE AT THE OUTER EDGE. COORDINATE WITH CIVIL DRAWINGS. REFER TO PROJECT SOILS REPORT REFERENCED ON DRAWING S001 FOR ADDITIONAL INFORMATION. 17.PROVIDE ISOLATED SLAB BELOW WALK IN COOLER. REFER TO SECTION 7/S210 FOR DETAIL AT JOINT. COORDINATE FINAL DIMENSIONS WITH COOLER MANUFACTURER. 18.THE LOADING DOCK SLAB ON GRADE SHALL BE 6" THICK. POUR SLAB OVER 4" OF WASHED GRANULAR FILL ON COMPACTED STRUCTURAL FILL. REINFORCE SLAB WITH EPOXY COATED 6x6-W2.9xW2.9 WELDED WIRE REINFORCING IN SHEET FORM. TOP OF SLAB SHALL SLOPE FROM ELEVATION 100'-0" AT BUILDING FACE TO YARD DRAINS AND GRADE AT PERIMETER AS REQUIRED. COORDINATE WITH PLUMBING AND CIVIL DRAWINGS. REFER TO PROJECT SOILS REPORT REFERENCED ON DRAWING S001 FOR ADDITIONAL INFORMATION. 19.REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATION SECTION 03350 FOR LOCATION AND LEVEL OF POLISHED CONCRETE FOR FLOOR SLABS. NOTES: 1.REFER TO GENERAL NOTES AND SPECIFICATIONS FOR INFORMATION PERTAINING TO FOUNDATIONS, FORMWORK, CAST-IN-PLACE CONCRETE AND REINFORCING. 2.ALL FOUNDATIONS HAVE BEEN DESIGNED BASED ON THE ALLOWABLE NET BEARING PRESSURE (ANBP) LISTED IN THE SCHEDULE AND AS INDICATED IN THE EARTHWORK/FOUNDATION NOTES ON DRAWING S001. 3.REFER TO THE PROJECT MANUAL AND SUBSURFACE INVESTIGATION AND GEOTECHNICAL RECOMMENDATIONS REPORT FOR ADDITIONAL INFORMATION PERTAINING TO FOUNDATIONS AND CONCRETE NOT SHOWN IN THE DETAILS, PLANS OR GENERAL NOTES. 4.ALL SIDES OF FOOTINGS SHALL BE FORMED UNLESS SPECIFICALLY APPROVED OTHERWISE BY THE EOR. 5.REFER TO DRAWING S300 FOR TYPICAL DETAILS PERTAINING TO FOUNDATION CONSTRUCTION. No.Description Date C D B 1 1 2 3 3 4 AA 5 5 6 6 E 1.2 D.8 1.4 2.4 2.3 3.7 A.9 C.3 C.5 W12X16 (10)W14X22 (12)W21X55 (14)W16X31 (16) W30X116 (24)W24X68 (17)W18X60(16)W24X55W24X68 (11)W24X68 (20)W16X67(26)W12X16 W21X44 (14)W24X55(25)W24X62(20)W24X55 (9)W30X90(35)W16X50(12)W12X26 W18X40 HSS12X6X1/2W24X55 W24X68W12X16(8)W18X40 (14)W18X35(15)W12X19(10)W14X22(10)W12X16(8)W18X40 (20)W16X26W24X55 W24X55W24X68(28)W24X55W18X35W24X55(26)W10X15 W24X55(27)W24X55(26)W24X55(26)W24X55(19)W24X55W12X16(8)W12X19(10)W12X19(10)W16X31(14)W16X31(14)W12X19(10)W12X19(10)W12X19(10)W12X16(8)W12X16(8)W24X55(26)W16X26(12)W16X26(12)W18X40(19)W10X15 (8)W10X15W10X15(8)W14X22(10)W18X35(19)W12X16W12X16(12)W16X36(16)W16X36(16)W24X55(20)W12X16 W18X35(18)124' - 10" 19' - 5"30' - 5"24' - 10"15' - 6"34' - 8" 124' - 10" 1' - 6"8' - 8"12' - 6"12' - 6"15' - 0"24' - 8"25' - 2"24' - 10" 5' - 3"8'-0"78'-8"30'-111/4"20'-103/4"26'-10"77'-4"22'-0"21'-10"13'-6"12'-6"7'-6"5 1/4" COMPOSITE SLAB T/SLAB (115'-0") SEE NOTE 6 5 1/4" COMPOSITE SLAB T/SLAB (114'-0") SEE NOTE 6 W12X16HSS12X4X1/4 W24X68 (17)W21X44(22)2'-0"13'-67/8"W16X31(15)W16X31(15)W16X31(15)W24X55(26)W16X26(12)W12X16(8)W12X16(8)W12X16(8)S250 1 SOUTH FRAMING ELEVATION S250 3WEST FRAMINGELEVATIONW10X15W12X16 4 S220 7 S220 6 S220 3 S220 2 S220 1 S220 4 S220 5 S220 4 S220 1 S220 4 S220 W12X16W12X16 6 S220 6 S220 5 7/8" EOS 71/2"EOS3"EOS3"EOS SEE NOTE 8 4"EOS 2 S220 1' - 1" EOS 7 S220 41/2"31/4"EOSEOS3"EOS4" EOS 4"EOS4"EOS 4 S220 (TYP.) 5 1/4"EOS 3"EOSSEE NOTE 8 11 3/4"EOS 5'-111/8"41/2"EOSWIND GIRT (H) S251 1 SOUTH PATIO FRAMING ELEVATION S251 2WESTPATIO FRAMINGELEVATION7' - 8"7' - 7"6' - 4"6' - 2"6' - 2"6' - 2"5' - 2"5' - 2"5' - 2"7' - 7"7' - 7"111/4"4' - 8"4' - 9"5' - 1"5' - 1" 5' - 0" 5' - 0 3/4"4' - 7 1/4"4'-81/2"6' - 1"6' - 1"6' - 0"6' - 8"6' - 4"6' - 5 1/4" 5' - 10"5' - 10"5' - 11 3/4"11'-83/8"4' - 11"4' - 10"4' - 10"4' - 10" FD 2'-113/4"8'-51/2"1' - 4 1/4" 5' - 7 5/8" HSS6X4X5/16HSS6X4X5/16 FD FD FD 4' - 4"4' - 4"6' - 3"6' - 3"6' - 3"6' - 3"6' - 9"6' - 8" 1' - 7" 1' - 2 5/8"EOS 101/4"EOS8"EOS 11 S220 12 S220 10 S220 3 S221 9 S220 1 S221 2 S221T/STEEL(115'-0")**** * *************W12X19(10)W10X15 W10X15 W10X15 3'-3"1'-5"2'-8"4'-11"2' - 8" 7' - 4"4' - 7" 4' - 10" 1' - 3"EOS EOSU.N.O.6"RD RD RD RD SEENOTE11SEENOTE11SEENOTE11SEE 5/S250 FOR ENTRY FRAMING ELEVATION EAST SEE 4/S250 FOR ENTRY FRAMING ELEVATION WEST S120 2 5' - 11"5' - 11"5' - 11"5' - 11"5' - 11"3' - 3 3/4"5'-7"1'-13/4"SEE 3/S251 FOR TYPICAL FRAMING BAY FD 4 E 4 E S250 1 SOUTH FRAMING ELEVATION MC18X42.7MC18X42.7MC18X42.7W8X24W8X24W8X13 W8X13W8X13W8X13 W8X13 MC18X42.7 MC18X42.7MC18X42.74 S2214 S221 W8X13 5 S221 S221 6 (TYP.) 7 S221(TYP.) ** ** ******** ****W8X13 W8X13**** 1 1/2" METAL DECK SEE NOTE 13 HSS4X4X1/4 HSS4X4X1/4 HANGER HANGER 8 S221 RD www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR As indicated 3/30/201710:51:12AMS120 SECOND FLOOR FRAMING PLAN Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 1/8" = 1'-0"S120 1 SECOND FLOOR FRAMING PLAN PLAN NOTES: 1.REFER TO DRAWING S001 FOR GENERAL NOTES, ABBREVIATIONS AND PLAN ANNOTATION SYMBOL KEY. 2.REFER TO DRAWING S310 FOR TYPICAL COMPOSITE SLAB REINFORCING DETAILS. 3.REFER TO DRAWING S505 FOR TYPICAL STEEL CONNECTION DETAILS. 4.REFER TO DRAWING S510 FOR TYPICAL FLOOR FRAMINNG DETAILS. 5.THE TOP OF STEEL SHALL BE AT ELEVATION (114'-6 3/4") TYPICAL U.N.O. THE TOP OF ALL BEAMS DENOTED WITH AN * SHALL BE AT ELEVATION (113'-6 3/4"). 6.THE FLOOR SLAB SHALL BE 3 1/4" LIGHTWEIGHT CONCRETE OVER 2" 20 GAUGE GALVANIZED COMPOSITE METAL DECK (TOTAL THICKNESS = 5 1/4"). SLAB SHALL BE REINFORCED WITH 6x6-W2.1xW2.1 WIRE MESH REINFORCING IN SHEET FORM SUPPORTED BY BOLSTERS. TOP OF SLAB SHALL BE AT ELEVATION (115'-0") U.N.O. 7.PROVIDE FRAMED OPENINGS FOR MISCELLANEOUS PENETRATIONS THROUGH THE FLOOR SLAB PER DETAIL 5/S510. THE GC SHALL COORDINATE THE SIZE AND LOCATIONS OF ALL OPENINGS IN WALLS, SLABS, ETC. WITH THE VARIOUS TRADES. 8.COORDINATE EDGE OF SLAB DIMENSION WITH METAL STAIR DETAILER. SLAB EDGE SHALL BE PER DETAIL 4/S220. 9.O FD DENOTES A FLOOR DRAIN. SLAB SHALL BE SLOPED LOCALLY AROUND FLOOR DRAINS TO PROVIDE APPROPRIATE DRAINAGE. 10.RD DENOTES A ROOF DRAIN. FRAME AROUND PENETRATIONS PER DETAIL 5/S510. COORDINATE WITH ARCHITECTURAL ROOF PLAN AND PLUMBING FOR SIZE AND LOCATIONS OF DRAINS. 11.PROVIDE FITTED STIFFENER PLATES BELOW PERGOLA POST LOCATIONS, (4) LOCATIONS PER BEAM (12 TOTAL). REFER TO DETAIL 8/S220. 12.THE TOP OF STEEL FOR ENTRANCE CANOPY BEAMS NOTED WITH A ** SHALL BE AT ELEVATION (109'-10"). THE TOP OF STEEL FOR CHANNEL MEMBERS AROUND THE PERIMETER OF THE ENTRANCE CANOPY SHALL BE AT ELEVATION (110'-3"). 13.THE ROOF DECK SHALL BE 1 1/2" 20 GAUGE GALVANIZED WIDE-RIB METAL DECK. 14.REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATION SECTION 03350 FOR LOCATION AND LEVEL OF POLISHED CONCRETE FOR FLOOR SLABS. 1/4" = 1'-0"S120 2 ENTRANCE CANOPY FRAMING PLAN No.Description Date C D B 1 1 2 3 3 4 AA 5 5 6 6 E 1.2 D.8 1.4 2.4 2.3 3.7 A.9 C.3 C.5 W12X16 (10)W14X22 (12)W21X55 (14)W16X31 (16) W30X116 (24)W24X68 (17)W18X60(16)W24X55W24X68 (11)W24X68 (20)W16X67(26)W12X16 W21X44 (14)W24X55(25)W24X62(20)W24X55 (9)W30X90(35)W16X50(12)W12X26 W18X40 HSS12X6X1/2W24X55 W24X68W12X16(8)W18X40 (14)W18X35(15)W12X19(10)W14X22(10)W12X16(8)W18X40 (20)W16X26W24X55 W24X55W24X68(28)W24X55W18X35W24X55(26)W10X15 W24X55(27)W24X55(26)W24X55(26)W24X55(19)W24X55W12X16(8)W12X19(10)W12X19(10)W16X31(14)W16X31(14)W12X19(10)W12X19(10)W12X19(10)W12X16(8)W12X16(8)W24X55(26)W16X26(12)W16X26(12)W18X40(19)W10X15 (8)W10X15W10X15(8)W14X22(10)W18X35(19)W12X16W12X16(12)W16X36(16)W16X36(16)W24X55(20)W12X16 W18X35(18)124' - 10" 19' - 5"30' - 5"24' - 10"15' - 6"34' - 8" 124' - 10" 1' - 6"8' - 8"12' - 6"12' - 6"15' - 0"24' - 8"25' - 2"24' - 10"78'-8"30'-111/4"20'-103/4"26'-10"77'-4"22'-0"21'-10"13'-6"12'-6"7'-6"5 1/4" COMPOSITE SLAB T/SLAB (115'-0") SEE NOTE 6 W12X16HSS12X4X1/4 W24X68 (17)W21X44(22)W16X31(15)W16X31(15)W16X31(15)W24X55(26)W16X26(12)W12X16(8)W12X16(8)W12X16(8)W10X15W12X16 W12X16W12X16 WIND GIRT (H) HSS6X4X5/16HSS6X4X5/16 **** * *************V = 40 KIPS M = 47 K-FT P = 2 KIPS V = 40 KIPS M = 50 K-FT P = 2 KIPS V = 77 KIPS M = 198 K-FT P = 3 KIPS V = 69 KIPS M = 154 K-FT V = 16 KIPS M = 76 K-FT P = 3 KIPS V = 36 KIPS M = 113 K-FT P = 1 KIP V = 62 KIPS M = 160 K-FT P = 4 KIPS V = 79 KIPS M = 195 K-FT V = 52 KIPS M = 200 K-FT P = 3 KIPS V = 60 KIPS M = 215 K-FT P = 4 KIPS V = 52 KIPS M = 161 K-FT P = 3 KIPS V = 69 KIPS M = 95 K-FT P = 4 KIPSV=33KIPSM=65K-FTV=36KIPSM=178K-FTV=71KIPSM=209K-FTV=72KIPSM=281K-FTP=2KIPSV=20KIPSM=142K-FTP=2KIPSV=12KIPSM=83K-FTP=3KIPSV=10KIPSM=43K-FTV=10KIPSM=37K-FTV=27KIPSM=153K-FTP=3KIPSV=26KIPSM=143K-FTP=3KIPSV=37KIPSM=185K-FTP=2KIPSV=34KIPSM=122K-FTP=3KIPSV=59KIPSM=110K-FTV=28KIPSM=152K-FTP=2KIPSV=11KIPSM=73K-FTV=15KIPSM=93K-FTP=1KIPV=15KIPSM=101K-FTP=1KIPV=13KIPSM=98K-FTP=2KIPSV = 19 KIPS P = 1 KIP V = 23 KIPS P = 1 KIP V = 23 KIPS P = 2 KIPS V = 33 KIPS P = 2 KIPS V = 10 KIPS P = 3 KIPS V = 118 KIPS P = 3 KIPS V = 102 KIPS P = 1 KIP V = 57 KIPS P = 1 KIP V = 57 KIPS P = 1 KIP V = 45 KIPS P = 4 KIPS V = 50 KIPS P = 3 KIPS V = 67 KIPS P = 4 KIPS V = 11 KIPS P = 1 KIP V = 19 KIPS P = 1 KIP V = 19 KIPS P = 2 KIPS V = 19 KIPS P = 2 KIPS V = 19 KIPS P = 3 KIPS V = 23 KIPS P = 3 KIPS V = 39 KIPS P = 3 KIPS V = 41 KIPS P = 2 KIPS V = 10 KIPS P = 2 KIPS V = 42 KIPS P = 4 KIPSV=74KIPSP=3KIPSV=23KIPSP=3KIPSV=21KIPSP=3KIPSV=22KIPSP=3KIPSV=12KIPSP=2KIPSW10X15 W10X15 W10X15 www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 1/8" = 1'-0"3/30/201710:51:13AMS121 SECOND FLOOR CONNECTION LOADS Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 1/8" = 1'-0"S121 1 SECOND FLOOR FRAMING LATERAL CONNNECTION LOADS NOTES: 1.STEEL CONNECTIONS THAT ARE PART OF THE LATERAL FORCE RESISTING SYSTEM SHALL BE DESIGNED BY THE STEEL FRABRICATOR'S CONNECTION ENGINEER FOR THE LOADS NOTED ON THE PLANS. 2.CALCULATIONS FOR STEEL CONNECTIONS SHALL BE SIGNED AND SEALED BY A LICENSED PROFESSIONAL ENGINEER IN THE STATE OF INDIANA AND SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL. 3.ALL CONNECTION LOADS PROVIDED AREE PER THE AISC LRFD LOAD COMBINATIONS IN ACCORDANCE WITH IBC 2012 AND ASCE 7-10. No.Description Date C B 1 2 3 3 4 5 5 6 6 E 3.7 A.9 C.3W14X26 W18X40 W18X40 W12X19 W21X55 W18X35 W12X19 W18X35 W14X30 W24X62W14X34W18X40 W16X26 W12X19W14X30 W14X30 24K524K524K524K5W16X26W16X2624K824K524K524K5W18X3524K824K8W16X2624K824K824K524K5W14X2614K114K1W18X3514K114K1W18X3514K1W14X22W16X45W16X36W18X35W14X34W18X4614K122'-0"124' - 10" 19' - 5"30' - 5"24' - 10"27' - 6"22' - 8"57'-91/4"30'-111/4"26'-10"8'-0"74' - 8" 25' - 2"24' - 10"24' - 8" 1 1/2" METAL DECK SEE NOTE 5 1 1/2" METAL DECK SEE NOTE 5 T/STEEL @ ELEV. (128'-10 1/2") T/STEEL @ ELEV. (129'-6 7/8") T/STEEL @ ELEV. (130'-1 1/8") T/STEEL @ ELEV. (129'-10 1/2") T/STEEL @ ELEV. (126'-2 1/2") S250 1 SOUTH FRAMING ELEVATION S2502EASTFRAMINGELEVATION S250 3WEST FRAMINGELEVATION8 S230 6 S230 7 S230 4 S230 3 S230 1 S230 9 S230 2 S230 1 S230 5 S230 W18X35 T/S (129'-4")W8X13T/S(128'-7")5' - 6"5' - 6"3' - 8"4' - 3"4' - 4"4' - 3"6' - 3"6' - 3" 2' - 2" 6' - 5"6' - 5"3' - 4"4' - 9"4' - 9"6' - 4"6' - 2"6' - 3"6' - 3"6' - 2"8'-51/2"1' - 4 1/4" 10 S230 W12X16 W12X16 5'-0"12'-41/2"T/STEEL @ (129'-1 15/16") T/STEEL @ (129'-1 11/16") T/STEEL @ (128'-8 5/16") 6' - 1"5' - 2"W16X26W/HSS4x21/2x1/4W/HSS4x21/2x1/4W/HSS4x21/2x1/4W/HSS4x21/2x1/4W/HSS4x21/2x1/4W/HSS4x21/2x1/411 S230 11 S230 W/HSS4x21/2x1/4W/HSS4x21/2x1/411 S230 W/HSS4x21/2x1/411 S230 W/HSS4x21/2x1/411 S230 4' - 4"2' - 3"W16X26SEE NOTE 7 SEE NOTE 7 SEE NOTE 7SEE NOTE 7 HORIZONTAL BRIDGING SEE NOTE 8 (TYP.) HORIZONTAL BRIDGING SEE NOTE 8 (TYP.)W18X355' - 6"2' - 6"SEENOTE10SEENOTE10SEENOTE10www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 1/8" = 1'-0"3/30/201710:51:14AMS130 ROOF FRAMING PLAN Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 1/8" = 1'-0"S130 1 ROOF FRAMING PLAN PLAN NOTES: 1.REFER TO DRAWING S001 FOR GENERAL NOTES, ABBREVIATIONS AND PLAN ANNOTATION SYMBOL KEY. 2.REFER TO DRAWING S505 FOR TYPICAL STEEL CONNECTION DETAILS. 3.REFER TO DRAWING S510 FOR TYPICAL FLOOR FRAMING DETAILS. 4.THE TOP OF STEEL SLOPES AS NOTED ON THE PLAN. ELEVATIONS SHOWN ARE DECK BEARING LEVELS AND ARE VALID FOR NORTH/SOUTH SLOPED MEMBERS. EAST/WEST GIRDER ELEVATIONS SHALL BE 2 1/2" LOWER TO ACCOUNT FOR BAR JOIST BEARING. 5.THE ROOF DECK SHALL BE 1 1/2" 20 GAUGE GALVANIZED WIDE-RIB METAL DECK. 6.PROVIDE FRAMED OPENINGS FOR MISCELLANEOUS PENETRATIONS THROUGH THE ROOF DECK PER DETAIL 5/S510. THE GC SHALL COORDINATE THE SIZE AND LOCATIONS OF ALL OPENINGS IN WALLS, SLABS, ETC. WITH THE VARIOUS TRADES. 7.PROVIDE FRAMED OPENINGS AROUND ALL ROOF PENETRATIONS PER DETAIL 5/S510. COORDINATE WITH MEP AND ARCHITECTURAL DRAWINGS FOR SIZES AND LOCATIONS OF ALL PENETRATIONS. 8.PROVIDE 1 1/2"x7/64" CONTINUOUS HORIZONTAL JOIST BRIDGING AT TOP AND BOTTOM CHORDS AS SHOWN ON PLAN. BRIDGING SHALL BE AT THIRD POINTS OF JOISTS AND SHALL BE SPACED AT NO MORE THAN 7'-6" O.C. FROM NEXT LINE OF BRIDGING OR JOIST END SUPPORT. ANY ADJUSTMENTS TO BRIDGING LOCATIONS IN THE PORTION OF THE BUILDING WHERE THE FINISHED STRUCTURE IS TO REMAIN EXPOSED MUST BE APPROVED BY THE ARCHITECT/ENGINEER. ATTACHMENT OF BRIDGING TO JOIST CHORDS AND BEAMS SHALL BE MADE BY WELDING OR MECHANICAL MEANS AND MUST BE CAPABLE OF RESISTING A NOMINAL UNFACTORED HORIZONTAL FORCE OF 700 LB. IN AREAS WHERE THERE IS NO CEILING AND BRIDGING IS TO REMAIN EXPOSED IN THE FINISHED STRUCTURE, ALL BRIDGING SHALL ALIGN IN A SINGLE LINE. 9.ALL ROOF JOISTS AND BRIDGING SHALL BE DESIGNED FOR A NET FACTORED UPLIFT OF 8 LB/SQFT. AS A MINIMUM, A SINGLE LINE OF BOTTOM CHORD BRIDGING SHALL BE PROVIDED NEAR THE FIRST BOTTOM CHORD PANEL POINT AT EACH END OF THE JOIST. 10.COORDINATE SIZE AND LOCATION OF BEAMS TO SUPPORT BRIDGE CRANE IN DISTILLERY. No.Description Date C B 1 2 3 3 4 5 5 6 6 E 3.7 A.9 C.3W14X26 W18X40 W18X40 W12X19 W21X55 W18X35 W12X19 W18X35 W14X30 W24X62W14X34W18X40 W16X26 W12X19W14X30 W14X30 24K524K524K524K5W16X26W16X2624K824K524K524K5W18X3524K824K8W16X2624K824K824K524K5W14X2614K114K1W18X3514K114K1W18X3514K1W14X22W16X45W16X36W18X35W14X34W18X4614K122'-0"124' - 10" 19' - 5"30' - 5"24' - 10"27' - 6"22' - 8"57'-91/4"30'-111/4"26'-10"74' - 8" 25' - 2"24' - 10"24' - 8" T/STEEL @ ELEV. (128'-10 1/2") T/STEEL @ ELEV. (129'-6 7/8") T/STEEL @ ELEV. (130'-1 1/8") T/STEEL @ ELEV. (129'-10 1/2") T/STEEL @ ELEV. (126'-2 1/2") W18X35 W8X13W12X16 W12X16W16X26W/HSS4x21/2x1/4W/HSS4x21/2x1/4W/HSS4x21/2x1/4W/HSS4x21/2x1/4W/HSS4x21/2x1/4W/HSS4x21/2x1/4W/HSS4x21/2x1/4W/HSS4x21/2x1/4V = 11 KIPS M = 39 K-FT P = 2 KIPS V = 12 KIPS M = 48 K-FT V = 11 KIPS M = 49 K-FT P = 2 KIPS V = 12 KIPS M = 57 K-FTV=10KIPSM=21K-FTP=1KIPV=10KIPSM=17K-FTV=10KIPSM=44K-FTV=10KIPSM=32K-FTV=14KIPSM=83K-FTV=10KIPSM=39K-FTV=21KIPSM=110K-FTV=33KIPSM=155K-FTP=1KIPV=10KIPSM=62K-FTP=4KIPSV=10KIPSM=55K-FTV=10KIPSM=39K-FTV=10KIPSM=49K-FTV=10KIPSM=57K-FTV=10KIPSM=49K-FTV=12KIPSM=40K-FTV=16KIPSM=84K-FTP=2KIPSV=17KIPSM=94K-FTP=2KIPSV=14KIPSM=58K-FTV = 21 KIPS M = 74 K-FT V = 20 KIPS M = 49 K-FT P = 4 KIPS V = 32 KIPS M = 111 K-FT P = 3 KIPS V = 30 KIPS M = 119 K-FT P = 4 KIPS V = 15 KIPS M = 66 K-FT P = 4 KIPS V = 14 KIPS M = 57 K-FT V=10KIPSP=4KIPSW/HSS4x21/2x1/4V = 10 KIPS P = 2 KIPS V = 10 KIPS P = 2 KIPS V = 20 KIPS P = 4 KIPS V = 23 KIPS P = 2 KIPS V = 10 KIPS P = 2 KIPS V = 16 KIPS P = 3 KIPS V = 21 KIPS P = 4 KIPS V = 19 KIPS P = 4 KIPS V = 20 KIPS P = 2 KIPS V = 19 KIPS P = 2 KIPSW16X26 www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 1/8" = 1'-0"3/30/201710:51:15AMS131 ROOF FRAMING CONNECTION LOADS Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 1/8" = 1'-0"S131 1 ROOF FRAMING LATERAL CONNECTION LOADS NOTES: 1.STEEL CONNECTIONS THAT ARE PART OF THE LATERAL FORCE RESISTING SYSTEM SHALL BE DESIGNED BY THE STEEL FRABRICATOR'S CONNECTION ENGINEER FOR THE LOADS NOTED ON THE PLANS. 2.CALCULATIONS FOR STEEL CONNECTIONS SHALL BE SIGNED AND SEALED BY A LICENSED PROFESSIONAL ENGINEER IN THE STATE OF INDIANA AND SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL. 3.ALL CONNECTION LOADS PROVIDED AREE PER THE AISC LRFD LOAD COMBINATIONS IN ACCORDANCE WITH IBC 2012 AND ASCE 7-10. No.Description Date T/SLAB @ ELEV. (100'-0") 6 1/2"1' - 3"6 1/2"1'-0"1' - 8" T/FTG. PER PLAN (3)#5 CONT. #4 SUPPORT BARS @ 48" O.C. #4@12" O.C. E.W. E.F. #4@12" O.C. E.W. E.F. 2' - 4" 3/4" CHAMFER 1/2" COMPRESSIBLE FILLER AND SEALANT RIGID INSULATION PER ARCH. T/SLAB @ ELEV. (100'-0") 1' - 3"6 1/2"1'-0"1' - 8" T/FTG. PER PLAN (3)#5 CONT. #4 SUPPORT BARS @ 48" O.C. #4@12" O.C. E.W. E.F. #4@12" O.C. E.W. E.F. 2' - 4" 3/4" CHAMFER 1/2" COMPRESSIBLE FILLER AND SEALANT T/STEEL @ ELEV. (102'-0") L4x4x3/8, CONT. HSS6x3x1/4 CONT. HSS6x3x1/4 @ 4'-0" O.C. 10 3/8" 1/2"x8"x1'-0" PLATES W/(4)1/2"x4" HWS @ 4'-0" O.C. 1/4 1/4 2-12 RIGID INSULATION PER ARCH. NOTE: SEE ELEVATION 1/S250. D T/SLAB @ ELEV. (100'-0")1'-0"1'-7" AT SIM. 1' - 5" T/FTG. PER PLAN (3)#5 CONT. #4 SUPPORT BARS @ 48" O.C. #4@12" O.C. E.W. E.F. #4@12" O.C. E.W. E.F. 2' - 4" 1/2" COMPRESSIBLE FILLER AND SEALANT T/STEEL @ ELEV. (102'-3") HSS6x3x1/4 CONT. HSS6x3x1/4 @ 4'-0" O.C. 1/2"x8"x1'-0" PLATES W/(4)1/2"x4" HWS @ 4'-0" O.C. 1.4 AT SIM. 8 1/8" 6 1/2"1' - 3" 1/4 RIGID INSULATION PER ARCH. NOTE: SEE ELEVATIONS 1/S251 & 2/S251. #6@12" O.C. T/SLAB @ ELEV. (100'-0") 11"6 1/2"1'-0"1'-6 1/8" @ SIM. 1' - 5 3/4" T/FTG. PER PLAN (3)#5 CONT. #4 SUPPORT BARS @ 48" O.C. #4@12" O.C. E.W. E.F. #4@12" O.C. E.W. E.F. 2' - 0" 3/4" CHAMFER 1/2" COMPRESSIBLE FILLER AND SEALANT RIGID INSULATION PER ARCH. 1 T/SLAB @ ELEV. (100'-0") 11"6 1/2"1'-0"1' - 6 1/8" T/FTG. PER PLAN (3)#5 CONT. #4 SUPPORT BARS @ 48" O.C. #4@12" O.C. E.W. E.F. #4@12" O.C. E.W. E.F. 2' - 0" 3/4" CHAMFER 1/2" COMPRESSIBLE FILLER AND SEALANT 8 1/2"9 5/8"8"RIGID INSULATION PER ARCH. 6"10"6"1' - 0" T/SLAB @ ELEV. (100'-0") THICKENED SLAB PER 9/S305 (1) #4 CONT. HORZ. #4@18" O.C. VERT. 3/4" CHAMFER (TYP.) SEALANT ON BOTH SIDES T/SLAB PER PLAN 1'-0"6" 8"4'-0"8"2 1 PIT SLAB @ ELEV. (96'-0") #4@10" O.C. E.W. #4@10" O.C. E.W. #5@12" O.C. E.W. T&B #5@12" O.C. E.W. T&B #4@18" O.C. x 3'-0" 1'-6" (2) #4 CONT. SUPPORT BARS SILL ANGLE W/ (3) 3/4" HILTI KB3 EXP. ANCHORS EMBEDDED 3 3/4", COORD. SIZE, LENGTH AND LOCATION OF ANGLE W/ ELEVATOR MANUFACTURER WATERPROOFING PER ARCH. T/SLAB @ ELEV. (100'-0")1'-0"1' - 8" T/FTG. PER PLAN (3)#5 CONT. #4 SUPPORT BARS @ 48" O.C. #4@12" O.C. E.W. E.F. #4@12" O.C. E.W. E.F. 2' - 4" 3/4" CHAMFER 1/2" COMPRESSIBLE FILLER AND SEALANT RIGID INSULATION PER ARCH. 1' - 3"1' - 1" 1' - 4 7/8"#4x3'-0" @ 18" O.C. W/(3)#4 CONT. SUPPORT BARS DOCK SLAB PER PLAN T/WALL @ ELEV. (99'-4") T/SLAB @ ELEV. (100'-0")1/2"OVERHEAD DOOR LOC. COORD. W/ 6 1/2"1' - 3"6 1/2"1'-0"T/FTG. PER PLAN (3)#5 CONT. #4 SUPPORT BARS @ 48" O.C. #4@12" O.C. E.W. E.F. #4@12" O.C. E.W. E.F. 2' - 4" 1/2" COMPRESSIBLE FILLER AND SEALANT RIGID INSULATION PER ARCH. SLAB PER PLAN @ ELEV. (100'-0") WALK-IN COOLER PER ARCH. 1/2" RIGID INSULATION 2'-0"3'-8"8"6'-4"(2)#4x2'-0"W/(2)#4 SUPPORT BARS AT EA. PIER FDN (EPOXY COATED) 3'-0" #3 TIES @ 10" O.C. (8)#5 VERT. 2' - 0" ø PRESSURE TREATED FENCE POST PER PLAN SLAB ON GRADE PER PLAN PER PLAN 5 7/8" SEE NOTE ALUMINUM RAILING PER ARCH. COLUMN PER PLAN #3@12" O.C. TIES (EPOXY COATED) 2 1 T/PIER @ ELEV. (99'-0") PIER PER PLAN 2" NON-SHRINK GROUT8"MIN.8"BASE PLATE AND ANCHOR RODS PER PLAN (2)#7 CONT. TOP & BOTTOM SLAB ON GRADE PER PLAN #6x @12" O.C. W/(2)#4 CONT. SUPPORT BARS (EPOXY COATED) 6'-0" NOTE: COORDINATE FINAL LOCATION OF ALUMINUM RAILING WITH ARCH DRAWINGS. EDGE OF SLEEVE SHALL BE NO CLOSER THAN 2" FROM EDGE OF SLAB. www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR As indicated 3/30/201710:51:17AMS210 SECTIONS Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 3/4" = 1'-0"S210 1 SECTION 3/4" = 1'-0"S210 5 SECTION 3/4" = 1'-0"S210 6 SECTION 3/4" = 1'-0"S210 9 SECTION 3/4" = 1'-0"S210 10 SECTION 3/4" = 1'-0"S210 11 SECTION 3/4" = 1'-0"S210 12 SECTION 3/4" = 1'-0"S210 2 SECTION 3/4" = 1'-0"S210 3 SECTION 3/4" = 1'-0"S210 7 SECTION 3/4" = 1'-0"S210 8 SECTION 1" = 1'-0"S210 4 SECTION No.Description Date T/SLAB @ ELEV. (100'-0") VERT HSS PER PLAN 1/2"x6"x10" PLATE W/(4)1/2"x4" HWS 1/4 8"1"4" 1" 8" PER 12/S210 4"4" **COORDINATE WITH PLUMBING FOR SIZE OF PREFABRICATED STAINLESS STEEL TRENCH DRAIN. PREFABRICATED STAINLESS STEEL TRENCH DRAIN PER PLUMBING DWGS T/SLAB PER PLAN MIN.6"#4@12" O.C. (5)#4 CONT.****T/SLAB @ ELEV. (100'-0") 11"6 1/2"1'-0"1'-6 1/8" @ SIM. 1' - 5 3/4" T/FTG. PER PLAN (3)#5 CONT. #4 SUPPORT BARS @ 48" O.C. #4@12" O.C. E.W. E.F. #4@12" O.C. E.W. E.F. 2' - 0" 1/2" COMPRESSIBLE FILLER AND SEALANT RIGID INSULATION PER ARCH. THICKENED SLAB PER 9/S305 (1) #4 CONT. HORIZ. #4@18" O.C. VERT. 3/4" CHAMFER (TYP.) SEALANT 1' - 0"10"(2)#4x2'-0"W/(2)#4 SUPPORT BARS AT EA. PIER FDN (ALL SLAB BARS EPOXY COATED) 3'-0" #3 TIES @ 10" O.C. GALV. COLUMN PER PLAN SLAB ON GRADE PER PLAN 5'-8"8"COLUMN BASE PLATE AND ANCHOR RODS PER PLAN (8)#5 VERT. 2' - 0" ø 2" NON-SHRINK GROUT (3)#4x2'-0"x EPOXY COATED 3'-0" #3 TIES @ 12" O.C. GALV. COLUMN PER PLAN SLAB ON GRADE PER PLAN COLUMN BASE PLATE AND ANCHOR RODS PER PLAN 2" NON-SHRINK GROUT (12)#6 VERT. PRESSURE TREATED FENCE POST EMBEDDED IN CONCRETE PER PLAN 3' - 0" DIA. (2)#4 SUPPORT BARS 2'-0"3'-8"8"6'-4"www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/4" = 1'-0"3/30/201710:51:19AMS211 SECTIONS Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 3/4" = 1'-0"S211 1 SECTION 3/4" = 1'-0"S211 2 SECTION 3/4" = 1'-0"S211 3 SECTION 3/4" = 1'-0"S211 4 SECTION 3/4" = 1'-0"S211 5 SECTION No.Description Date 10 3/8"T/STEEL @ ELEV.(117'-0") T/SLAB@ ELEV.(115'-0") B/STEEL @ ELEV.(109'-0") HSS 6x3x1/4 @ 4'-0" O.C. L4x4x3/8 CONT. (HOT-DIP GALV.) GALV. HSS 3x3x1/4" @ 3'-0" O.C. L5x3 1/2x3/8(LLH) CONT. (HOT-DIP GALV.)51/4"4" COMPOSITE SLAB PER PLAN NOTE: SEE ELEVATION 1/S250 ERECTION BOLT AND SLOTTED HOLES 1/4 3 SIDES TYP. (2) L4x3x5/16 @ EA. VERT. (TYP.) 1/4 3-12 HSS6x3x1/4, CONT. HSS6x3x1/4, CONT. SLAB EDGE PER 3/S510 1/4 3-12 L4x4x5/16, CONT. 1/4 TYP. BOTH ENDS OF HSS 3 1' - 7" 10 7/8"T/SLAB@ ELEV.(115'-0")51/4"51/4"T/SLAB@ ELEV.(114'-0") BEAM PER PLAN (TYP.) BEAM COMPOSITE SLAB PER PLAN(5) #4 CONT. SUPPORT BARS #4@18" O.C. L3x3x5/16 CONT. 1/4 2-12 3 1' - 7" 10 7/8" T/SLAB@ ELEV.(115'-0")51/4"51/4"T/STEEL@ ELEV.(118'-3") BEAM PER PLAN (TYP.) BEAM T/SLAB@ ELEV.(114'-0") COMPOSITE SLAB PER PLAN(5) #4 CONT. SUPPORT BARS #4@18" O.C. L3x3x5/16 CONT. HSS6x3x1/4 CONT. HSS6x3x1/4 @ 4'-0" O.C. 1/2"x8"x1'-0" PLATES W/(4)1/2"x4" HWS @ 4'-0" O.C. NOTE: SEE ELEVATION 3/S250. 1/4 TYP. BOTH ENDS T/SLAB @ ELEV. (115'-0") BEAM PER PLAN COMPOSITE SLAB PER PLAN PER PLAN 51/4"SLAB EDGE PER 3/S510 T/STEEL @ ELEV. (114'-6 3//4") 6 BEAM PER PLAN 4" METAL STUD PER ARCH. SLIDE CLIP BY METAL STUD SUPPLIER L4x4x5/16 CONT. TOP & BOT 3/16 3-12 TYP. T/SLAB @ ELEV. (115'-0") BEAM PER PLAN COMPOSITE SLAB PER PLAN PER PLAN 51/4"SLAB EDGE PER 3/S510 METAL STUD PER ARCH. SLIDE CLIP BY METAL STUD SUPPLIER T/SLAB PER PLAN 51/4"BEAM PER PLAN COMPOSITE SLAB PER PLAN PER PLAN POUR STOP T/STEEL @ ELEV.(116-0") T/SLAB @ ELEV.(114'-0") B/STEEL @ ELEV.(109'-0") HSS 6x3x1/4 @ 4'-0" O.C. HSS 6x3x1/4 CONT. C12x20.7 CONT, GALV 51/4"10 1/8" 5 1/8" GALV. HSS 4x3x1/4 @ 12'-0" O.C. 1 1/8"x10"x10" (HOT-DIP GALV.) AT EACH VERT. 9 1/2"10"1'-2"HSS 6x3x1/4 CONT. L3x3x1/4 @ EA. VERT.4"NOTE: SEE ELEVATIONS 1/S251 & 2/S251. B/STEEL @ ELEV.(109'-1") ERECTION BOLT AND SLOTTED HOLES 1/4 TYP. BOTH ENDS 1/4 3 SIDES TYP. (2) L4x3x5/16 @ EA. VERT. 1/4 BEAM PER PLAN (TYP.) 1/4 TYP. BOTH ENDS OF HSS BEAM PER PLAN WT13.5x51 T/STEEL@ ELEV.(115'-0") T/STEEL @ ELEV.(114'-11 3/4") 3-12 1/4 3-12 1 B WIND GIRT PER PLAN GIRT @ ELEV. (114'-6")METAL STUD PER ARCH SLIDE CLIP BY METAL STUD SUPPLIER B T/STEEL @ ELEV.(114'-6 3/4") 7" 3/16 2-12 TYP. BEAM, PER PLAN L7x4x3/8 (LLH) CONT. TOP & BOT. SLIDE CLIP BY METAL STUD SUPPLIER METAL STUD PER ARCH T/SLAB PER PLAN 51/4"BEAM PER PLAN COMPOSITE SLAB PER PLAN BEAM PAIR OF 1/2" FITTED STIFFENER PLATES BELOW EACH PERGOLA POST PERGOLOA POST PER ARCH. www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR As indicated 3/30/201710:51:21AMS220 SECTIONS Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 3/4" = 1'-0"S220 1 SECTION 3/4" = 1'-0"S220 2 SECTION 3/4" = 1'-0"S220 3 SECTION 3/4" = 1'-0"S220 4 SECTION 3/4" = 1'-0"S220 5 SECTION 3/4" = 1'-0"S220 6 SECTION 3/4" = 1'-0"S220 7 SECTION 3/4" = 1'-0"S220 9 SECTION 1 1/2" = 1'-0"S220 10 SECTION 1" = 1'-0"S220 11 SECTION 3/4" = 1'-0"S220 12 SECTION 3/4" = 1'-0"S220 8 SECTION No.Description Date T/STEEL @ ELEV.(114'-6 3/4")1/4"MIN.L6x4x5/16 (LLV) W/3/4"ø A325 BOLT IN LONG-SLOTTED HOLE VERT. HSS PER PLAN VERT. HSS PER PLAN 1/4 BEAM PER PLAN T/SLAB @ ELEV.(115'-0") L6x4x5/16 (LLV) W/3/4"ø A325 BOLT IN LONG-SLOTTED HOLE VERT. HSS PER PLAN VERT. HSS PER PLAN 1/4 4 3/4" BEAMS, PER PLAN 1"MIN.51/4"COMPOSITE SLAB, PER PLAN 1/2"x6"x10" EMBED PLATE W/(4)1/2"x4" HWS C.3 6" T/STEEL @ ELEV.(116-0") T/SLAB @ ELEV.(114'-0") B/STEEL @ ELEV.(109'-0") HSS 6x3x1/4 @ 4'-0" O.C. HSS 6x3x1/4 CONT. C12x20.7 CONT, GALV 10 1/8" 5 1/8" GALV. HSS 4x3x1/4 @ 12'-0" O.C. 1 1/8"x10"x10" (HOT-DIP GALV.) AT EACH VERT. 9 1/2"10"HSS 6x3x1/4 CONT. L3x3x1/4 @ EA. VERT.4"NOTE: SEE ELEVATIONS 1/S251 & 2/S251. B/STEEL @ ELEV.(109'-1") ERECTION BOLT AND SLOTTED HOLES 1/4 TYP. BOTH ENDS 1/4 3 SIDES TYP. (2) L4x3x5/16 @ EA. VERT. 1/4 BEAM PER PLAN 1/4 TYP. BOTH ENDS OF HSS L3x3x5/16 KICKERS TO NEXT BEAM @ 3'-0" O.C. T/STEEL @ ELEV. (110'-6") GALV. CHANNEL PER PLAN 1 1/2" GALV. METAL ROOF DECK L3x3x1/4, CONT. T/STEEL @ ELEV. (109'-10") 1/4 2-12 T/STEEL @ ELEV. (110'-6") BEAMS PER PLAN (TYP) 1 1/2" GALV. METAL ROOF DECK T/STEEL @ ELEV. (109'-10") BEAM 4"T/SLAB @ ELEV.(115'-0") GALV. CHANNEL PER PLAN CONNECTION PER 4/S501 OR 5/S501 (TYP. TOP & BOTTOM) 5' - 7"1' - 11"2' - 1 1/2"10 1/4"5' - 1" L3x3x1/4, BTWN BEAMS 1/4 2-12 HSS HANGER PER PLAN T/STEEL @ ELEV.(115'-6") B/STEEL @ ELEV.(110'-1 1/4") HSS 6x3x1/4 @ 4'-0" O.C. L5x3 1/2x3/8(LLH) CONT. (HOT-DIP GALV.) COMPOSITE SLAB PER PLAN NOTE: REFER TO SECTION 2/S222 FOR INFORMATION NOT SHOWN HERE. ERECTION BOLT AND SLOTTED HOLES (2) L4x3x5/16 @ EA. VERT. (TYP.) HSS6x3x1/4, CONT. TOP & BOTT. SLAB EDGE PER 3/S510 L4x4x5/16, CONT. (INTERRUPT AT HANGERS) 6"L6x3 1/2x5/16, CONT. 10 3/8"51/4"HSS COLUMN PER PLAN 1/4 AT TUBE (TYP.) CHANNEL PER PLAN (TYP.) PROVIDE ALL AROUND WELD, GROUND SMOOTH AT MITERED CORNER 7 S221 T/STEEL @ ELEV. (110'-6") BEAM PER PLAN 1 1/2" GALV. METAL ROOF DECK T/STEEL @ ELEV. (109'-10") 1/4 AT CHANNEL 1/2" PLATE HSS COLUMN PER PLAN BEAMS PER PLAN (TYP) T/STEEL @ ELEV. (109'-10") HANGER T/SLAB @ ELEV.(115'-0") CONNECTION PER 4/S501 OR 5/S501 (TYP. TOP & BOTTOM) 1/4 TYP. BOTH ENDS HSS HANGER PER PLAN (TYP.) HANGER L3x3x1/4, WELD TO FACE OF HSS AT TOP & STIFFENER PLATE AT BOTTOM COMPOSITE SLAB PER PLAN FLOOR BEAM PER PLAN www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR As indicated 3/30/201710:51:23AMS221 SECTIONS Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 1" = 1'-0"S221 1 SECTION 1" = 1'-0"S221 2 SECTION 3/4" = 1'-0"S221 3 SECTION 1" = 1'-0"S221 4 SECTION 1" = 1'-0"S221 5 SECTION 1" = 1'-0"S221 6 SECTION 1" = 1'-0"S221 7 SECTION 1" = 1'-0"S221 8 SECTION No.Description Date 10 3/8" T/STEEL @ ELEV.(115'-6")T/SLAB@ ELEV.(115'-0") B/STEEL @ ELEV (110'-1 1/4") HSS 6x6x1/4 PER LOCATIONS ON 1/S250 L5x3 1/2x3/8(LLH) CONT. (HOT-DIP GALV.)51/4"4" COMPOSITE SLAB PER PLAN NOTES: 1. SEE ELEVATION 1/S250. 2. COORDINATE SIZE AND LOCATIONS OF BARREL SUPPORT STEEL WITH MANUFACTURER. 3. REFER TO SECTIONS 2/S222 AND 5/S230 FOR INFORMATION NOT SHOWN OR CALLED OUT. 1/4 3-12 HSS6x3x1/4, CONT. HSS6x3x1/4, CONT. SLAB EDGE PER 3/S510 1/4 3-12 L4x4x5/16, CONT. 1/4 TYP. BOTH ENDS OF HSS 10 3/8" T/STEEL @ ELEV. (131'-3 3/8") T/STEEL PER PLAN B/STEEL @ ELEV.(127'-3 1/8") 4" E HSS 6x3x1/4 @ 4'-0" O.C. L5x3 1/2x3/8 (LLH) CONT. HOT-DIP GALV.)JOIST PER PLAN 3" HSS6x3x1/4 CONT. T&B L4x4x5/16, CONT. TOP & BOT (GALV.) 1 1/2" GALV. METAL ROOF DECK ERECTION BOLT AND SLOTTED HOLES NOTE: SEE ELEVATION 1/S250. 3' - 0" L3x3x1/4 KICKERS @ 4'-0" O.C. L4x4x1/4 BTWN JOISTS, WELD ALL AROUND @ BOTH ENDS HSS4x2 1/2x1/4 BTWN JOISTS (GALV.)2'-0"2'-0"8'-0"4"7 3/8"1' - 0 7/8" HSS4x4x1/4 W/ 1"x8"x8" PLATE SEE NOTE 2 1/4 TYP. BOTH ENDS OF HSS L4x4x5/16 AT EA. 6X6 TUBE, WELD ALL AROUND BOTH ENDS 10 3/8" T/STEEL @ ELEV.(115'-6") T/SLAB@ ELEV.(115'-0") B/STEEL @ ELEV.(110'-11 1/4") HSS 6x3x1/4 @ 4'-0" O.C. GALV. HSS 3x3x1/4" @ 3'-0" O.C. L5x3 1/2x3/8(LLH) CONT. (HOT-DIP GALV.)51/4"4"COMPOSITE SLAB PER PLAN NOTE: SEE ELEVATIONS 1/S250, 4/S250 & 5/S250. ERECTION BOLT AND SLOTTED HOLES 1/4 3 SIDES TYP. (2) L4x3x5/16 @ EA. VERT. (TYP.) 1/4 3-12 HSS6x3x1/4, CONT. HSS6x3x1/4, CONT. SLAB EDGE PER 3/S510 1/4 3-12 L4x4x5/16, CONT. 1/4 TYP. BOTH ENDS OF HSS www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/4" = 1'-0"3/30/201710:51:24AMS222 SECTIONS Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 3/4" = 1'-0"S222 1 SECTION 3/4" = 1'-0"S222 2 SECTION No.Description Date 10 3/8" T/STEEL @ ELEV.(131'-3 3/8") T/STEEL SLOPES PER PLAN B/STEEL @ ELEV.(124'-0") 4" HSS 6x3x1/4 @ 4'-0" O.C. GALV. HSS 3x3x1/4 @ 3'-0" O.C. L5x3 1/2x3/8(LLH) CONT. (HOT-DIP GALV.) BEAM PER PLAN JOIST PER PLAN E 3" HSS6x3x1/4 CONT. L4x4x5/16, CONT. TOP & BOT (GALV.) 3/16 3-12 TYP. HSS6x3x1/4 CONT. 1 1/2" GALV. METAL ROOF DECK ERECTION BOLT AND SLOTTED HOLES 1/4 3 SIDES TYP. (2) L4x3x5/16 @ EA. VERT. (TYP.) 1/4 TYP. BOTH ENDS OF HSS NOTE: SEE ELEVATION 1/S250. HSS4x2 1/2x1/4 BTWN JOISTS (GALV.) 3' - 0" L4x4x1/4 BTWN JOISTS, WELDED ALL AROUND AT BOTH ENDS L3x3x1/4 KICKERS @ 4'-0" O.C. 10 3/8" T/STEEL @ ELEV.(131'-3 3/8") T/STEEL PER PLAN B/STEEL @ ELEV.(126'-2 3/8") 4" 6 HSS 6x3x1/4 @ 4'-0" O.C. GALV. HSS 3x3x1/4 @ 3'-0" O.C. L5x3 1/2x3/8 (LLH) CONT. HOT-DIP GALV.) BEAM PER PLAN 3" HSS6x3x1/4 CONT. T&B L4x4x5/16, CONT. TOP & BOT (GALV.) 3/16 3-12 TYP. 1 1/2" GALV. METAL ROOF DECK ERECTION BOLT AND SLOTTED HOLES 1/4 3 SIDES TYP. (2) L4x3x5/16 @ EA. VERT. (TYP.) 1/4 TYP. BOTH ENDS OF HSS NOTE: SEE ELEVATION 2/S250. L4x4x5/16 KICKERS @ 4'-0" O.C. HSS4X2 1/2x1/4 CONT., STITCH WELDED TO WF BEAM (GALV.) T/STEEL PER PLAN A.9 4" JOIST PER PLAN BEAM PER PLAN L4x4x5/16, CONT. (GALV.) 3/16 2-12 METAL STUD PER ARCH. SLIDE CLIP BY METAL STUD SUPPLIER 1 1/2" GALV. METAL ROOF DECK 3' - 0" L4x4x1/4 BTWN JOISTS, WELD ALL AROUND @ BOTH ENDS L3x3x1/4 KICKERS @ 4'-0" O.C. HSS4x2 1/2x1/4 BTWN JOISTS (GALV.) 10 3/8" T/STEEL @ ELEV.(131'-3 3/8") T/STEEL PER PLAN B/STEEL @ ELEV.(124'-0") 4" 3 HSS 6x3x1/4 @ 4'-0" O.C. GALV. HSS 3x3x1/4" @ 3'-0" O.C. L5x3 1/2x3/8" (LLH) CONT. HOT-DIP GALV.) BEAM PER PLAN 3" HSS6x3x1/4 CONT. L4x4x5/16, CONT. TOP & BOT (GALV.) 3/16 3-12 TYP. HSS6x3x1/4 CONT. 1 1/2" GALV. METAL ROOF DECKERECTION BOLT AND SLOTTED HOLES 1/4 3 SIDES TYP. (2) L4x3x5/16 @ EA. VERT. (TYP.) 1/4 TYP. BOTH ENDS OF HSS NOTE: SEE ELEVATIONS 2/S250 & 3/S250. HSS4X2 1/2x1/4 CONT., STITCH WELDED TO WF BEAM (GALV.) L4x4x1/4 KICKERS @ 4'-0" O.C. 10 3/8" T/STEEL PER PLAN B/STEEL @ ELEV.(126'-2 3/8") 4" 3 2' - 2" JOIST T/STEEL PER PLAN 6" T/STEEL @ ELEV.(131'-3 3/8") HSS 6x3x1/4 @ 4'-0" O.C. GALV. HSS 3x3x1/4 @ 3'-0" O.C. L5x3 1/2x3/8 (LLH) CONT. (HOT-DIP GALV.) 3" HSS6x3x1/4 CONT. T&B L4x4x5/16, CONT. TOP & BOT (GALV.) 3/16 3-12 TYP. BEAM PER PLAN 1 1/2" GALV. METAL ROOF DECK HSS4x2 1/2x1/4 CONT., STITCH WELD TO WF BEAM (GALV.) BRICK VENEER PER ARCH. 1 1/2" GALV. METAL ROOF DECK L6x4x5/16, CONT. JOIST PER PLAN ERECTION BOLT AND SLOTTED HOLES 1/4 3 SIDES TYP. (2) L4x3x5/16 @ EA. VERT. (TYP.) 1/4 TYP. BOTH ENDS OF HSS NOTE: SEE ELEVATION 3/S250. L4x4x1/4 KICKERS @ 4'-0" O.C. T/STEEL SLOPES PER PLAN B 7" 1' - 3 1/4" BEAM PER PLAN JOIST PER PLAN 3/16 3-12 TYP. L7x4x3/8 (LLH), CONT. BENT PLATE PER 4/S510 (GALV.) 1 1/2" GALV. METAL ROOF DECK HSS4x2 1/2x1/4 BTWN JOISTS (GALV.) METAL STUDS PER ARCH. SLIDE CLIP BY METAL STUD SUPPLIER 3' - 0" L4x4x1/4 BTWN JOISTS, WELD ALL AROUND @ BOTH ENDS L3x3x1/4 KICKERS @ 4'-0" O.C. T/STEEL SLOPES PER PLAN C 7" 1' - 3 3/4" JOIST PER PLAN BEAM PER PLAN L7x4x3/8 (LLH), CONT. BENT PLATE PER 4/S510 (GALV.) 1 1/2" GALV. METAL ROOF DECK HSS4x2 1/2x1/4 BTWN JOISTS (GALV.) METAL STUDS PER ARCH. SLIDE CLIP BY METAL STUD SUPPLIER 3' - 0" L4x4x1/4 BTWN JOISTS, WELD ALL AROUND @ BOTH ENDS L3x3x1/4 KICKERS @ 4'-0" O.C. 1 T/STEEL PER PLAN 7" 1' - 3 7/8" BEAM PER PLAN BENT PLATE PER 4/S510 1 1/2" GALV. METAL ROOF DECK METAL STUDS PER ARCH. SLIDE CLIP BY METAL STUD SUPPLIER 3/16 3-12 TYP. L7x4x3/8 (LLH), CONT. L4x4x1/4 KICKERS @ 4'-0" O.C. HSS4X2 1/2X1/4 CONT., STITCH WELDED TO WF BEAM (GALV.) 10 3/8" T/STEEL @ ELEV. (131'-3 3/8") T/STEEL PER PLAN B/STEEL @ ELEV.(127'-3 1/8") 4" E HSS 6x3x1/4 @ 4'-0" O.C. GALV. HSS 3x3x1/4 @ 3'-0" O.C. L5x3 1/2x3/8 (LLH) CONT. HOT-DIP GALV.)BEAM PER PLAN JOIST PER PLAN 3" HSS6x3x1/4 CONT. T&B L4x4x5/16, CONT. TOP & BOT (GALV.) 3/16 3-12 TYP. 1 1/2" GALV. METAL ROOF DECK ERECTION BOLT AND SLOTTED HOLES 1/4 3 SIDES TYP. (2) L4x3x5/16 @ EA. VERT. (TYP.) 1/4 TYP. BOTH ENDS OF HSS NOTE: SEE ELEVATION 1/S250. 3' - 0" L3x3x1/4 KICKERS @ 4'-0" O.C. L4x4x1/4 BTWN JOISTS, WELD ALL AROUND @ BOTH ENDS HSS4x2 1/2x1/4 BTWN JOISTS (GALV.) STEEL SLOPES PER PLAN 1 1/2" GALV. METAL ROOF DECK BEAMS PER PLAN (TYP.) L6x4x5/16 (LLV) W/3/4"ø A325 BOLT IN LONG-SLOTTED HOLE1"MIN.11/2"T/STEEL @ ELEV. (129'-4") T/VERT. @ ELEV. (127'-8 3/4") L6x4x5/16 (LLV) W/3/4"ø A325 BOLT IN LONG-SLOTTED HOLE VERT. HSS PER PLAN VERT. HSS PER PLAN T/STEEL @ ELEV. (128'-7") T/STEEL SLOPES PER PLAN BEAM PER PLAN 1 1/2" GALV. METAL ROOF DECK 21/2"HSS4x2 1/2x1/4 CONT., STITCH WELD TO WF BEAM www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR As indicated 3/30/201710:51:27AMS230 SECTIONS Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 3/4" = 1'-0"S230 1 SECTION 3/4" = 1'-0"S230 2 SECTION 3/4" = 1'-0"S230 9 SECTION 3/4" = 1'-0"S230 3 SECTION 3/4" = 1'-0"S230 4 SECTION 3/4" = 1'-0"S230 6 SECTION 3/4" = 1'-0"S230 7 SECTION 3/4" = 1'-0"S230 8 SECTION 3/4" = 1'-0"S230 5 SECTION 3/4" = 1'-0"S230 10 SECTION 1" = 1'-0"S230 11 SECTION No.Description Date 3 4 5 6 1 S220 1 S220 1 S222 1 S230 1 S230 5 S210 5 S210 5 S210 5 S210 5 S210 HSS6X3X1/4 HSS6X3X1/4 HSS6X3X1/4 HSS6X3X1/4 HSS6X3X1/4 HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4 HSS6X3X1/4 HSS6X3X1/4 HSS6X3X1/4 HSS6X3X1/4 HSS6X3X1/4 HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4T/FIRST FLOOR SLAB @ ELEV. (100'-0") T/STEEL @ ELEV. (102'-0") B /STEEL @ ELEV. (109'-0") T/SLAB @ ELEV. (115'-0") T /STEEL @ ELEV. (117'-0") B /STEEL @ ELEV. (124'-0") T /STEEL ELEV. PER PLAN T /STEEL @ ELEV. (131'-3 3/8") 4' - 0" 24' - 10"25' - 2"24' - 8" 4' - 0"4' - 0"4' - 0"4' - 0"4' - 0"4' - 0"2' - 0 1/4"3' - 4"3' - 4"3' - 4"1' - 10 1/2" B/STEEL @ ELEV. (127'-3 1/8") 4' - 0"4' - 0"4' - 0"4' - 0"4' - 0"4' - 0"4' - 0"4' - 0" 5 1/2"1' - 6 3/4" 2 1/2" 3 1/4"3' - 8 3/4" 6 3/4" 3' - 8"3' - 8"3' - 8" 1' - 4" 3' - 8"3' - 8"3' - 8"1' - 4"4' - 0"4' - 0"4' - 0"4' - 0"4' - 0"4' - 0"4' - 0"4' - 0"4' - 0" 3"3' - 9" 7" 3' - 3"3' - 1"2' - 3"3' - 1"3' - 3"3' - 3"1' - 7 1/2"3' - 1"1' - 9 1/2"3' - 3"3' - 3"3' - 3"3' - 1"3' - 3" 1' - 9 1/2"1' - 9 1/2" 3' - 1"3' - 3"2' - 3"3' - 1"3' - 1"1' - 9 1/2"HSS6X3X1/4HSS6X6X1/4HSS6X3X1/4HSS6X3X1/4 HSS6X3X1/4 1' - 3 1/2"1' - 2 1/2"2' - 9 1/2"3' - 6"HSS6X6X1/42 S222 2 S222 5 S230 T/STEEL @ ELEV. (115'-6") B/STEEL @ ELEV. (110'-1 1/4") E A.9C.3 2 S230 HSS6X3X1/4 HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4T/STEEL ELEV. PER PLAN T/STEEL @ ELEV. (131'-3 3/8") B/STEEL @ ELEV. (126'-2 3/8") 4' - 0"4' - 0"4' - 0" 26' - 10"30' - 11 1/4" 4' - 0"4' - 0"4' - 0"4' - 0"4' - 0"4' - 0"4' - 0"4' - 0"4' - 0"4' - 0" 2' - 1 3/8"1' - 10 5/8" 1' - 0 5/8"8 5/8"4' - 0" CB EA.9 C.3 3 S230 4 S230 3 S220 T/SLAB @ ELEV. (115'-0") T/STEEL @ ELEV. (131'-3 3/8") T/STEEL ELEV. PER PLAN B/STEEL @ ELEV. (124'-0")B/STEEL @ ELEV. (126'-2 3/8")3'-3"HSS6X3X1/4HSS6X3X1/4 HSS6X3X1/4 HSS6X3X1/4 HSS6X3X1/4 3' - 7"3' - 7"3' - 7"1' - 4 5/8" 4' - 0"4' - 0"4' - 0"3' - 10 1/2" 22' - 0"8' - 0"26' - 10" 4' - 0"4' - 0"4' - 0"4' - 0" 2' - 0" 10 1/8"1' - 3 1/8"3' - 10 1/2" 9"3' - 1 1/2" 3' - 10 1/2"3' - 10 1/2"3' - 10 1/2"3' - 10 1/2" 5 5/8"5 5/8"HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/44' - 0" 2' - 0" T/STEEL @ ELEV. (118'-6") 1' - 6" 11 1/4" E 2 S222 T/SLAB @ ELEV. (115'-0") T/STEEL @ ELEV. (117'-0") B/STEEL @ ELEV. (110'-1 1/4") HSS6X3X1/4 HSS6X3X1/4 HSS6X3X1/4HSS6X3X1/411 1/2" 7/8" 2 S222 HSS6X3X1/4 HSS6X3X1/4HSS6X3X1/4HSS6X3X1/41' - 10" T/SLAB @ ELEV. (115'-0") T/STEEL @ ELEV. (115'-6") B/STEEL @ ELEV. (110'-1 1/4") www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR As indicated 3/30/201710:51:31AMS250 FRAMING ELEVATIONS Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 1/4" = 1'-0"S250 1 SOUTH FRAMING ELEVATION 1/4" = 1'-0"S250 2 EAST FRAMING ELEVATION 1/4" = 1'-0"S250 3 WEST FRAMING ELEVATION 1/2" = 1'-0"S250 4 ENTRY FRAMING ELEVATION WEST 1/2" = 1'-0"S250 5 ENTRY FRAMING ELEVATION EAST No.Description Date 2 31.2 1.4 2.4 6 S210 6 S210 6 S210 9 S220 T/FIRST FLOOR SLAB @ ELEV. (100'-0") T/PATIO SLAB @ ELEV. (114'-0") HSS6X3X1/4 HSS6X3X1/4 HSS6X3X1/4 HSS6X3X1/4 HSS6X3X1/4 4' - 0" 12' - 6"12' - 6"8' - 8"15' - 0" 4' - 0"4' - 0" 3/4"3' - 11 1/4" 4' - 0"4' - 0"4' - 0" 6 3/4"3' - 5 1/4"1' - 10 3/4"1' - 8" 3' - 6 3/4"4' - 0"4' - 0"4' - 0"4' - 0"4' - 0" 5 1/4"3' - 6 3/4"1' - 1 1/4"HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4T/STEEL @ ELEV. (116'-0") B/STEEL @ ELEV. (109'-1")HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/42'-3"2'-3"2'-3"3' - 3"3' - 3"3' - 3"3' - 9 1/2" 1' - 5 1/2"1' - 9 1/2" 3' - 3"3' - 3"3' - 3" 11 1/2"1' - 3 1/2" 3' - 3"3' - 3"3' - 3" 1' - 5 1/2" C D D.8C.5 6 S210 9 S2204 5/8"3' - 7 3/8"1 3/8"3' - 10 5/8"1' - 10 5/8"4 5/8"3' - 7 3/8" 4' - 0"4' - 0"4' - 0"4' - 0" 12' - 6"7' - 6" 4' - 0"4' - 0" 4 1/8" 4' - 0"4' - 0" 3' - 3"3' - 3"3' - 3"1' - 11 1/2"9 1/2" T/FIRST FLOOR SLAB @ ELEV. (100'-0")2'-3"HSS6X3X1/4 HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4T/PATIO SLAB @ ELEV. (114'-0") HSS6X3X1/4 HSS6X3X1/4 13' - 6"HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4HSS6X3X1/4T/STEEL @ ELEV. (116'-0") B/STEEL @ ELEV. (109'-1") EQUAL EQUAL PER PLAN 11/2"11/2"ELEV. (106'-10 1/2") POST POST PRESSURETREATED6x6PRESSURETREATED2x6PRESSURETREATED6x6PRESSURE TREATED 2x6 11/2"ELEV. (100'-3 1/2") ELEV. (100'-0") PRESSURE TREATED 2x6 1 1/2" EMBED POST IN CONCRETE PER 8/S210 OR 5/S211 www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR As indicated 3/30/201710:51:32AMS251 FRAMING ELEVATIONS Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 1/4" = 1'-0"S251 1 SOUTH PATIO FRAMING ELEVATION 1/4" = 1'-0"S251 2 WEST PATIO FRAMING ELEVATION 1/2" = 1'-0"S251 3 TYPICAL SCREEN WALL BAY FRAMING No.Description Date FIELD APPLY ASPHALTIC PROTECTIVE COATING TO COLUMN, BASE PLATE, AND HEAD OF ANCHOR BOLTS. EXTEND 2" ABOVE FLOOR TYP. COLUMN BLOCK-OUT POURED AFTER SLAB IS POURED OR AS PART OF SLAB IF SLAB DOES NOT INCLUDE CONSTRUCTION JOINTS BASE PLATE SIZE PER PLAN OR COLUMN SCHEDULE SEE PLAN FOR SLAB THICKNESS, REINFORCING AND ELEVATION COLUMN PER PLAN OR SCHEDULE ANCHOR BOLTS WITH NUTS & WASHERS PER TYPICAL DETAIL LEVELING NUT & WASHER IN NON-SHRINK GROUT SPACE PER TYPICAL ANCHOR DETAIL T/FTG PER PLAN (1) CLOSED TIE W/ CROSS TIES IN FOOTING TIES CLOSED TIES WITH CROSS TIES @ 3" O.C. OVER THE LENGTH OF THE ANCHORS. SEE PIER DETAILS FOR SPACING BEYOND. SEE PLAN FOR PIER MARKS. SEE PIER DETAILS FOR SIZE AND REINFORCING COLUMN FOOTING SEE PLAN AND SCHEDULE T/PIER PER PLAN TYP.3"CLR.TYP. 3" CLR. TYP. 1 1/2" CLR.TYP.2"CLR.FIELD APPLY ASPHALTIC PROTECTIVE COATING TO COLUMN, BASE PLATE, AND HEAD OF ANCHOR BOLTS. EXTEND 2" ABOVE FLOOR TYP. COLUMN BLOCK-OUT POURED AFTER SLAB IS POURED OR AS PART OF SLAB IF SLAB DOES NOT INCLUDE CONSTRUCTION JOINTS BASE PLATE SIZE PER PLAN OR COLUMN SCHEDULE SEE PLAN FOR THICKNESS, REINFORCING AND ELEVATION COLUMN PER PLAN OR SCHEDULE ANCHOR BOLTS WITH NUTS & WASHERS PER TYPICAL DETAIL LEVELING NUT & WASHER IN NON- SHRINK GROUT SPACE PER TYPICAL ANCHOR DETAIL VAPOR RETARDER IF APPLICABLE T/FTG PER PLAN COLUMN FOOTING SEE PLAN & SCHEDULE COMPACTED GRANULAR FILL ISOLATION JOINT PER PLAN TYP. 3" CLR.TYP.3"CLR.TYP.2"CLR.CORNER BARS TO MATCH SIZE AND SPACING OF HORIZ. WALL REINF. EXTEND ALL HORIZONTAL REINF. BARS TO WITHIN 1 1/2" OF THE OUTSIDE FACE OF WALLS. STANDARD HOOK OR MIN. 8" TYP. KEYED CONST. JOINT NOTE: SEE SECTIONS FOR SIZE AND SPACING OF VERTICAL AND HORIZONTAL WALL REINFORCING WHICHEVER IS LONGER 40 BAR DIA. OR 24" LAP FOUNDATION WALL AND REINF. PER PLANS AND DETAILS COORDINATE INVERT ELEVATION OF OPENINGS W/ MECHANICAL, ELECTRICAL OR PLUMBING (2) #6 BARS x OPENING WIDTH + 6'-0" IN LENGTH SEEMECH.PLANSMIN. 1' - 0" BETWEEN OPENINGS U.N.O OR APPROVED BY STRUCTURAL ENGINEER (2) #6 BARS x OPENING WIDTH + 6'-0" IN LENGTH #5 EACH SIDE OF OPENING x OPENING WIDTH +4'-0" IN LENGTH FOR TYPICAL WALL REINFORCING, SEE PLAN AND DETAILS CONTACT A/E IF OPENING IS LARGER THAN 8'-0"T/3T/3T/33" PREVIOUS POUR NEW POUR PROVIDE 2-#5x3'-0" LONG THRU JOINT (IF NO TOP REINF. IN FTG.) PROVIDE KEY FULL WIDTH OF FOOTING PROVIDE FOOTING REINF CONT. THROUGH JOINT U.N.O1'-0"2"CLR.TOP OF SLEEVE DOES NOT INTERRUPT REINFORCING TOP OF SLEEVE INTERRUPTS BOTTOM REINFORCING 12" LEG (TYP)CONT WALL FOOTING REINFORCING PIPE SLEEVE 3" LARGER THAN PIPE DIAMETER LOOSE INSULATION PROVIDE DEEPENED WALL FOOTING AT PIPE BARS TO MATCH FOOTING REINFORCING KEEP 6" MIN OF CONCRETE ALL AROUND (4) #3 BARS TRANSVERSE 12 12" LEG (TYP)CONT WALL FOOTING REINFORCING PIPE SLEEVE 3" LARGER THAN PIPE DIAMETER LOOSE INSULATION PROVIDE DEEPENED WALL FOOTING AT PIPE #3 BARS @ 12" O.C. KEEP 6" MIN. OF CONCRETE ALL AROUND (4) #3 BARS TRANSVERSE 12 NOTE: THESE DETAILS DO NOT APPLY IF TOP OF PIPE IS MORE THAN 8" BELOW BOTTOM OF WALL FOOTING (16" MIN.) 2 x H HU.N.O.1'-0"1 2NOTE: REFER TO FOUNDATION PLAN FOR FOOTING STEP ELEVATIONS AND LOCATIONS CONTINUOUS WALL FOOTING REINFORCING, SEE PLAN & DETAILS (TYP.) (MIN.) 2' - 0" LAP (MIN.) 2' - 0" LAP(TYP.)3"CLR.(TYP.)3"CLR.(TP.)3"CLR.SEE PLAN PER SITE DRAWINGS SEE PLAN VARIES SEEPLANSLOPE PER SITE DRAWINGS #5 @ 18" O.C. 2'-6" 1'-6"(3) #5 CONT. T/FTG. PER PLAN #5 @ 18" O.C. 3'-0" 1'-6"SLAB PER PLAN 1/2" COMPRESSIBLE FILLER (LOCATE UNDER THRESHOLD) FDN WALL PER PLAN (2)#5 SUPPORT BARS TYPICALSEEPLAN .NOTE: REFER TO SECTIONS FOR WALL AND FNDN REINFORCING AND DIMENSIONS 2'-0"8" B B+D MINIMUM LIMIT OF STRUCTURAL FILL EXCAVATION LINE SOFT OR UNSUITABLE SOILS EXCAVATED AND REPLACED WITH COMPACTED STRUCTURAL FILL DT/FTG. ELEV. PER PLAN B = WIDTH OF FOOTING D = DEPTH OF SUITABLE SOILS FUTURE GRADE 3' - 0"1'-0"1'-6"2' - 0" ø (3)-#4 SHAPED BAR EACH WAY #5@12" O.C. EACH WAY TOP AND BOT. #5@12" O.C. EACH WAY TOP AND BOT. 1" GALVANIZED STEEL BAR GRATING B/ELEVATOR PIT PER PLAN ROLLED L1 1/4"x1 1/4"x1/4" HOT DIPPED GALVANIZED WITH 1/2"x6" LONG HEADED STUD @ 16" O.C. WATER STOP NOTE: COORDINATE LOCATION OF SUMP PIT W/ PLUMBING.1'-0"www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR As indicated 3/30/201710:51:34AMS300 TYPICAL FOUNDATION DETAILS Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 1/2" = 1'-0"S300 1 TYPCIAL COLUMN ON PIER DETAIL 1/2" = 1'-0"S300 2 TYPICAL COLUMN ON FOOTING DETAIL 3/4" = 1'-0"S300 5 TYPICAL CONCRETE WALL REINFORCEMENT AT CORNER AND INTERSECTION 3/4" = 1'-0"S300 6 TYPICAL FOUNDATION WALL PENETRATION DETAIL 3/4" = 1'-0"S300 4 WALL FOOTING CONSTRUCTION JOINT 3/8" = 1'-0"S300 7 TYPICAL PIPE SLEEVE THROUGH WALL FOOTING 3/4" = 1'-0"S300 8 TYPICAL STEPPED FOOTING DETAIL 3/4" = 1'-0"S300 9 TYPICAL STOOP DETAIL 1/2" = 1'-0"S300 3 FOUNDATION UNDERCUTTING DETAIL 1/2" = 1'-0"S300 10 TYPCIAL ELEVATOR SUMP PIT DETAIL No.Description Date 1' - 0"1'-0"1'-0"T/PIER @ ELEV. (99'-4") 1' - 0" 2' - 0"2'-0"#3 TIES @ 3" O.C. OVER ANCHOR RODS AND @ 12" O.C. THEREAFTER (8) #6 VERT. W/ 180 DEG. HOOKS AT TOP OF CORNER BARS 1' - 0"1'-0"1'-0"T/PIER @ ELEV. (99'-0") 1' - 0" 2' - 0"2'-0"#3 TIES @ 3" O.C. OVER ANCHOR RODS AND @ 12" O.C. THEREAFTER (8) #6 VERT. W/ 180 DEG. HOOKS AT TOP OF BARS 9"9"9"T/PIER @ ELEV. (99'-0") AT PATIO COLUMNS (99'-4") AT VESTIBULE COLUMNS 9" 1' - 6"1'-6"#3 TIES @ 12 " O.C. (4)#6 VERT. (4) #6 VERT. CONTINUE WALL BARS THROUGH PIER T/PIER @ ELEV. (99'-4") #3 TIES @ 12" O.C.9"5"1'-3"9"9" 1' - 6"1'-8"(8) #6 VERT. W/ 180 DEG. HOOK AT TOP OF CORNER BARS CONTINUE WALL BARS THROUGH PIER T/PIER @ ELEV. (99'-4") #3 TIES @ 3" O.C. OVER ANCHOR RODS AND @ 12" O.C. THEREAFTER 1' - 1"1' - 1"9"1'-1"11"2' - 2"1'-8"2' - 3" 1' - 1 1/2"1' - 1 1/2"1'-3"5"1'-11/2"1'-8"(8) #6 VERT.W/180 DEG HOOK AT TOP OF BARS CONTINUE WALL BARS THROUGH PIER T/PIER @ ELEV. (99'-4") #3 TIES @3" O.C. OVER ANCHOR RODS AND @ 12" O.C. THEREAFTER 11"63/4"10"1'-53/4"11"7 1/8"10" #3 TIES @ 3" O.C. OVER ANCHOR RODS AND @ 10" O.C. THEREAFTER (8)#5 VERT. W/180 DEG HOOKS AT TOP OF CORNER BARS 1' - 6 1/8" T/PIER @ ELEV. (99'-4") CONTINUE WALL BARS THROUGH PIER (TYP.) #3 TIES @ 3" O.C. OVER ANCHOR RODS AND @ 12" O.C. THEREAFTER (8) #6 VERT. W/ 180 DEG. HOOKS AT TOP OF BARS 1' - 3"5"1' - 0" 1' - 8"1'-3"5"1'-0"CONTINUE WALL BARS THROUGH PIER (TYP.)1'-8"T/PIER @ ELEV. (99'-4")#3 TIES @ 3" O.C. OVER ANCHOR RODS AND @ 10" O.C. THEREAFTER (8) #5 VERT. W/180 DEG. HOOKS AT TOP OF CORNER BARS 1' - 3"7"10" 1' - 10"1'-3"5"10"CONTINUE WALL BARS THROUGH PIER (TYP.)1'-8"T/PIER @ ELEV. (99'-4") (8) #6 VERT. W/ 180 DEG. HOOK AT TOP OF BARS CONTINUE WALL BARS THROUGH PIER T/PIER @ ELEV. (99'-4") #3 TIES @ 3" O.C. OVER ANCHOR RODS AND @ 12" O.C. THEREAFTER 10 1/2"10 1/2"63/4"101/2"11"1' - 9" #3 TIES @ 12" O.C. (4) #6 VERT. CONTINUE WALL BARS THROUGH PIER (TYP.) T/PIER @ ELEV. (99'-4")1'-8"1'-3"5"9"5"1' - 3" 1' - 8" 9" www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/4" = 1'-0"3/30/201710:51:37AMS302 CONCRETE PIER DETAILS Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 3/4" = 1'-0"S302 5 PIER PE 3/4" = 1'-0"S302 6 PIER PF 3/4" = 1'-0"S302 8 PIER PH 3/4" = 1'-0"S302 9 PIER PJ 3/4" = 1'-0"S302 10 PIER PK 3/4" = 1'-0"S302 1 PIER PA 3/4" = 1'-0"S302 2 PIER PB 3/4" = 1'-0"S302 3 PIER PC 3/4" = 1'-0"S302 4 PIER PD 3/4" = 1'-0"S302 12 PIER PL 3/4" = 1'-0"S302 7 PIER PG No.Description Date SLAB OPENING (SEE PLAN FOR PIT OR OTHER CONSTRUCTION BELOW OPENING) 1-#5 x 4'-0" EACH CORNER, TYP LOCATE REINFORCING WITH 2" CLR TO TOP OF SLAB TYPICAL21/2"CLRTYPICALEQUALTYPICALEQUALPLUMBINGDETAILSCOORDINATEWITHPIPE SET DRAIN PRIOR TO CONCRETE PLACEMENT SEE TYPICAL SLAB ON GRADE CONSTRUCTION DETAIL(S) FOR BELOW SLAB REQUIREMENTS TOP OF SLAB (OR FINISHED FLOOR) ELEVATION AT DRAIN PLANSEECMU WALL REFER TO PLANS FOR SIZE AND LAYOUT. REFER TO TYPICAL DETAILS FOR WALL REINFORCING.DRILL AND EPOXY GROUT DOWELS TO MATCH VERTICAL REINFORCING SIZE AND SPACINGDOWELS T/SLAB PER PLAN. SEE PLAN FOR THICKNESS AND REINFORCEMENT SEEPLANtS(8"MIN)2*ts(12" MIN.) 2*tw tw 1 1 (2)-#6 CONT.#4 SUPT. BARS ON BOLSTERS @ 3'-0" O.C.SEESCHEDULELAPSPLICENOTES: 1. SEE CONCRETE GENERAL NOTES AND SPECIFICATION SECTION 033000 - CAST-IN-PLACE CONCRETE FOR SLAB FINISH AND CURING REQUIREMENTS 2. SEE SPECIFICATION SECTION 312000 - EARTH MOVING FOR SUBGRADE MATERIAL AND COMPACTION REQUIREMENTS. SLAB ON GRADE PROVIDE MINIMUM OF 6" LAYER OF FREE DRAINING GRANULAR FILL MATERIAL COMPACTED TO AT LEAST 95% OF THE MODIFIED PROCTOR DENSITY (ASTM D1557). COORDINATE SUBGRADE REQUIREMENTS WITH GEOTECHNICAL REPORT SHEET VAPOR RETARDER WHERE INDICATED SEE SPECIFICATIONS WELDED WIRE MESH SHRINKAGE & TEMPERATURE REINFORCING WHERE INDICATED (SEE PLAN)PLANSEE1"CLRNOTES: 1. SAWCUT JOINT AS SOON AS POSSIBLE AFTER THE CONCRETE HARDENS. THE CONCRETE IS HARD ENOUGH WHEN THE BLADE DOES NOT DISLODGE AGGREGATE, AND WHEN THE EDGES OF THE CUT DO NOT RAVEL. COMPLETE SAWCUTTING BEFORE SHRINKAGE STRESSES BECOME SUFFICIENT TO PRODUCE CRACKING. 2. PREPARE AND SEAL JOINT AS SPECIFIED IN DIVISION 7 OF THE PROJECT MANUAL. 3. CURLING OF THE SLAB ON GRADE WILL OCCUR AT CONTROL JOINT LOCATIONS. FOR SLABS WITH FLOOR COVERINGS, GRINDING MAY BE REQUIRED FOR PROPER INSTALLATION OF FLOOR COVERING. 4. LAYOUT CONTROL JOINT LOCATIONS BEFORE SLAB CONSTRUCTION AND DISCONTINUE ANY SLAB REINFORCING AT JOINTS. 5. SEE SPECIFICATION 033000 FOR JOINT WIDTH & DEPTH WHEN SOFF-CUT SYSTEM IS USED FOR CUTTING CONTROL JOINTS.PLANSEESEE TYPICAL SLAB ON GRADE CONSTRUCTION DETAIL(S) FOR BELOW SLAB REQUIREMENTS 1/4" MAXIMUM JT WIDTH (SEE NOTE 5)(SEENOTE5)THKNS/4CONTINUOUS SAWCUT CONTROL JOINT (SEE NOTES 1 AND 2) 2"2" NOTES: 1. CONTRACTOR SHALL COORDINATE CONSTRUCTION JOINTS SUCH THAT THEY COINCIDE WITH CONTROL JOINT LOCATIONS SHOWN ON PLANS. SEE PLANS FOR LOCATIONS WHERE FULL-DEPTH CONSTRUCTION JOINTS ARE REQUIRED. 2. APPLY LIQUID BONDBREAKER TO FULL DEPTH OF CONSTRUCTION JOINT. 3. PREPARE AND SEAL JOINT AS SPECIFIED IN DIVISION 7 OF THE PROJECT MANUAL.PLANSEESEE TYPICAL SLAB ON GRADE CONSTRUCTION DETAIL(S) FOR BELOW SLAB REQUIREMENTS 1 2 1 2 CONTINUOUS 2x4 SHEAR KEY 6"6"8"MIN.NOTES: 1. SEE PLAN FOR SLAB RECESS LOCATIONS AND DIMENSIONS. SLAB ON GRADE SEE TYPICAL SLAB ON GRADE CONSTRUCTION DETAIL(S) FOR BELOW SLAB REQUIREMENTSTHICKNESS 2 x SLAB PLANSEE(SEENOTE1)SLABRECESS,RPROVIDE KEYWAY AT REQUIRED (SEE PLAN) OR OPTIONAL CONSTRUCTION JOINT LOCATIONS #4 @ 18" O.C. CONCRETE PIER NOTE 3 CJ CJ CJ CJ CJCJ CJCJTYPICAL2"CLRNOTE 4 TYPICAL2"CLRNOTE 3 AND 7 TYPICAL2"CLRNOTE 1 AND 7 CJCJNOTE 2 AND 7 BASE PLATE NOTE 4 CONCRETE PIER NOTE 1 AND 7 NOTE 4 BASE PLATETYPICAL2"CLRINTERIOR COLUMN WITHOUT PIER INTERIOR COLUMN WITH PIER NOTE 4 CONTROL OR CONSTRUCTION JOINT ON COLUMN CENTERLINES, TYP NOTE 4 NOTE 4 TYPICAL2"CLRCONCRETE PIER NOTE 1 AND 7 NOTE 5 NOTE 5 NOTE 5SLAB ON GRADE NOTES: COLUMN ISOLATION SECTION: DEPTH OF CONCRETE ISOLATION SECTION TO EXTEND TO TOP OF CONCRETE PIER. COLUMN ISOLATION SECTION: DEPTH OF CONCRETE ISOLATION SECTION TO EXTEND TO TOP OF FOOTING. COLUMN ISOLATION SECTION: DEPTH OF CONCRETE ISOLATION SECTION TO MATCH THICKNESS OF ADJACENT SLAB ON GRADE. PROVIDE BONDBREAKER BETWEEN COLUMN ISOLATION SECTIONS AND SLAB ON GRADE, UNLESS OTHERWISE NOTED. SEE PLAN FOR LOCATIONS WHERE ROUND ISOLATION JOINTS ARE REQUIRED. PROVIDE BONDBREAKER BETWEEN WALL OR GRADE BEAM AND SLAB ON GRADE, UNLESS OTHERWISE NOTED. "CJ" DENOTES SAWCUT CONTROL JOINT IN SLAB ON GRADE. SEE TYPICAL SLAB ON GRADE CONTROL JOINT DETAIL. AT BRACED-BAY COLUMNS, ENLARGE ISOLATION SECTION AS REQUIRED SUCH THAT PORTION OF BRACING THAT PENETRATES SLAB IS COMPLETELY WITHIN ISOLATION SECTION. PROVIDE (1) #4 REINFORCING IN ISOLATION SLAB AS INDICATED. LOCATE REINFORCING WITH 2" CLEAR TO TOP OF SLAB. DETAIL REINFORCING TO MATCH ISOLATION SLAB GEOMETRY, WITH STANDARD LAP LENGTHS AS REQUIRED AT BAR SPLICES (REDUCE LENGTHS AS REQUIRED BY ISOLATION SLAB GEOMETRY). 1. 2. 3. 4. 5. 6. 7. 8. NOTE 3 CJ TYPICAL2"CLRNOTE 46"6"CJ CJCJ CJCJ CJCJ CJNOTE 8 TYPICAL2"CLR2"CLRCOLUMN BASE PLATE OR CONCRETE PIER (NOTES 1, 2, AND 7 AS APPLICABLE) SPECIAL CONDITIONS TYPICAL11/2"CLRwww.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR As indicated 3/30/201710:51:39AMS305 TYPICAL SLAB ON GRADE REINFORCING Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 3/4" = 1'-0"S305 6 TYPICAL OPENING IN SLAB ON GRADE 1 1/2" = 1'-0"S305 7 TYPICAL FLOOR DRAIN 3/4" = 1'-0"S305 9 TYPICAL CMU WALL ON SLAB ON GRADE 1 1/2" = 1'-0"S305 1 TYPICAL SLAB ON GRADE CONSTRUCTION 1 1/2" = 1'-0"S305 3 TYPICAL SLAB ON GRADE CONTROL JOINT 1 1/2" = 1'-0"S305 2 TYPICAL SLAB ON GRADE CONSTRUCTION JOINT 1 1/2" = 1'-0"S305 4 TYPICAL SLAB ON GRADE DEPRESSION 3/8" = 1'-0"S305 5 TYPICAL COLUMN ISOLATION JOINT No.Description Date CENTERLINE OF COLUMN CENTERLINE OF COLUMN (1) #4 x 4'-0" TOP BAR TYPICAL AT EACH STEEL COLUMN CENTERLINE OF COLUMN CENTERLINE OF COLUMN (1) #4 x 4'-0" (1) #4 TOP 3'-0" 3'-0" EDGE OF SLAB SEEPLANSEE EDGE REINFORCING DETAIL CENTERLINE OF COLUMN (1) #4 x 4'-0" (1) #4 TOP 3'-0"3'-0" EDGE OF SLAB SEEPLANSEE EDGE REINFORCING DETAIL TOP OF SLAB - SEE PLAN SEE ELEVATED FLOOR PLANS FOR CONCRETE AND STEEL DECK INFORMATION SEE PLAN AND SLAB SCHEDULE FOR TYPICAL SLAB REINFORCING. SUPPORT WIRE MESH ON SLAB BOLSTERS AT 2'-6" O.C. WHERE NO REBAR BELOW IS REQUIRED.1"CLRTYP2' - 0"2' - 0" #4 AT 12" O.C. x 4'-0" LONG, CENTERED OVER ALL INTERIOR GIRDERS (WHERE DECK SPAN IS PARALLEL WITH GIRDER). LOCATE BELOW WIRE MESH AS INDICATED SUPPORT REINFORCING ON SLAB BOLSTERS AS INDICATED. SEE PLAN FOR TOP OF SLAB SEE PLAN EOS 1-#4 CONTINUOUS (LOCATE AT BOTTOM SIDE OF BENT PLATE SHEAR STUDS AS INDICATED) #5 WITH 180-DEG HOOK, AT 12" O.C. TYPICAL (TURN HOOKS AS REQUIRED TO MAINTAIN REQUIRED CLEAR COVER TO TOP OF SLAB) SEE TYPICAL COMPOSITE SLAB REINFORCING DETAIL(S) FOR INTERIOR REINFORCING REQUIREMENTS (IF ANY). INTERIOR REINFORCING SHALL EXTEND TO WITHIN 1" OF EDGE OF DECK, TYPICAL 1/2"CLRTYPSUPPORT REINFORCING ON SLAB BOLSTERS AS INDICATED.www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 1" = 1'-0"3/30/201710:51:40AMS310 TYPICAL COMPOSITE SLAB REINFORCING Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 1" = 1'-0"S310 3 TYPICAL COMPOSITE SLAB REINFORCEMENT AT INTERIOR COLUMN 1" = 1'-0"S310 5 TYPICAL COMPOSITE SLAB REINFORCEMENT AT CORNER COLUMN 1" = 1'-0"S310 4 TYPICAL COMPOSITE SLAB REINFORCEMENT AT EDGE COLUMN 1" = 1'-0"S310 1 TYPICAL COMPOSITE SLAB REINFORCING DETAIL 1" = 1'-0"S310 2 TYPICAL COMPOSITE SLAB REINFORCING AT EDGE No.Description Date 5/16 TYP.STEEL COLUMN PER PLAN OR SCHEDULE 3/4" BASE PLATE s/(4)3/4"ø A325 BOLTS STIFF PLATE EACH SIDE OF BEAM WEB ALIGN W/ FACE OF COLUMN FLANGE. MIN STIFF PLATE THICNESS TO MATCH COLUMN FLANGE THICKNESS 5/16 3 SIDES TYP FINISH END 5/16 TYP. STEEL COLUMN PER PLAN OR SCHEDULE 3/4" BASE PLATE W/(4) - 3/4" DIA. A325 BOLTS 1/2" STIFF PLATE EACH SIDE OF BEAM WEB ALIGN W/ OUTSIDE EDGE OF COLUMN FLANGE WIDTH 5/16 3 SIDES TYP FINISH END STIFF. PLATE EACH SIDE OF BEAM WEB ALIGN W/ COLUMN WEB. MIN. STIFF PLATE THICKNESS TO MATCH COLUMN WEB THICKNESS. 1/2" THICK STIFFENER PLATE EACH SIDE OF BEAM WEB ALIGN W/ COLUMN FLANGES. STIFFENER PLATE SHALL BE USED FOR SHEAR CONNECTION FOR BEAM IN XVERSE DIR. CONNECTION SHALL BE IAW BEAM-TO-COLUMN TYPICAL CONNECTION.5/16 3 SIDES TYP FINISH END 3/4"x12"x1'-4" CAP PLATE W/(4) - 3/4" DIA. A325 BOLTS STEEL COLUMN PER PLAN 5/16 TYP. 5/16 3 SIDES TYP FINISH END3/4" CAP PLATE W/(4) - 3/4" DIA. A325 BOLTS COLUMN PER PLAN 5/16 TYP. 1 1/2" 6 1/2"6 1/2" 1 1/2" 1/2" THICK STIFFENER PLATE EACH SIDE OF BEAM WEB ALIGN W/ CL. OF COLUMN OR COLUMN WEB. STIFFENER PLATE SHALL BE USED FOR SHEAR CONNECTION FOR BEAM IN XVERSE DIR. CONNECTION SHALL BE IAW BEAM- TO-COLUMN TYPICAL CONNECTION. STRONG AXIS WEAK AXIS 1/2" THICK STIFFENER PLATE EACH SIDE OF BEAM WEB ALIGN W/ CL. OF COLUMN OR COLUMN WEB. STIFFENER PLATE SHALL BE USED FOR SHEAR CONNECTION FOR BEAM IN XVERSE DIR. CONNECTION SHALL BE IAW BEAM-TO-COLUMN TYPICAL CONNECTION. Sb SbCb Cb = B/2 - Sb Cn=N/2-SnSnSnCnNB PLATE THICKNESS, Tbp PER SCHEDULE wbl 3"TYPE 1 OVER-SIZED ANCHOR HOLES (SEE NOTE 2) NOTES: 1. 2. REFER TO BASE PLATE SCHEDULE FOR ALL DIMENSIONS, THICKNESSES, NUMBER AND SIZE OF ANCHORS PROVIDE THE FOLLOWING ANCHOR HOLE DIAMETER BASED ON ANCHOR SIZE: 3/4" ANCHOR = 1 5/16" HOLE 1" ANCHOR = 1 13/16" HOLE 1 1/4" ANCHOR = 2 1/16" HOLE 2" ANCHOR = 3 1/4" HOLE NOTES: 1. 2. 3. 4. 5. 6. REFER TO GENERAL NOTES FOR INFORMATION PERTAINING TO STRUCTURAL STEEL CONSTRUCTION REFER TO PLAN OR COLUMN SCHEDULE FOR BASE PLATE MARK. REFER TO TYPICAL BASE PLATE DETAIL (THIS DRAWING) FOR BASE PLATE FABRICATION AND ATTACHMENT REQUIREMENTS. ANCHOR LAYOUT SHALL MATCH BASE PLATE HOLE LAYOUT SHOWN IN TYPICAL BASE PLATE DETAIL AND GIVEN IN THIS SCHEDULE. CONTRACTOR SHALL USE RIGID TEMPLATES TO SET ANCHORS IN CORRECT POSITION AND ELEVATION. ALL BASE PLATES SHALL BE A572 GRADE 50 STEEL.EMBEDMENTDEPTH,He(SEESCHEDULE)BASEPLATETHICKNESS,TbpTgr=2*DaNON-SHRINK,NON-METALICGROUTBEDLe=Tg+Tp+2*DaEXTENSIONANCHOR SIZE, Da TOP OF PIER OR FOUNDATION PER PLAN ASTM F1554 HEADED ANCHOR BOLT WITH DOUBLE NUTS AT TOP FOR LEVELING. REFER TO PLAN AND / OR COLUMN SCHEDULE FOR SIZE, GRADE, AND QUANTITY REQ'D AT EA. ANCHORAGE www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR As indicated 3/30/201710:51:42AMS501 TYPICAL STEEL COLUMN DETAILS Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 1" = 1'-0"S501 4 TYPICAL TRANSFER COLUMN DETAIL 1" = 1'-0"S501 5 TYPICAL BEAM OVER COLUMN DETAIL 1" = 1'-0"S501 2 TYPICAL BASE PLATE DETAILS 1" = 1'-0"S501 1 BASE PLATE SCHEDULE STEEL BASE PLATE SCHEDULE MARK GEOMETRY ANCHORAGE WELD SIZE, wblLENGTH, N WIDTH, B THICKNESS, Tp TYPE Sn Sb NUMBER, N SIZE BP1 12"12"1 1/2"1 4 1/2"4 1/2"4 3/4"3/8" BP2 10"10"3/4"1 3 1/2"3 1/2"4 3/4"3/16" BP3 11"11"3/4"1 4"4"4 3/4"3/16" BP4 13"13"1 1/4"1 5"5"4 1"5/8" BP5 16"14"1 1/2"1 6 1/2"5 1/2"4 3/4"3/16" BP6 16"16"1 1/2"1 6 1/2"6 1/2"4 1"5/8" BP7 16"16"1 1/4"1 6 1/2"6 1/2"4 1"1/2" BP8 13"13"1 3/8"1 5"5"4 3/4"5/16" BP9 13"13"1 1/2"1 5"5"4 1"3/8" 1 1/2" = 1'-0"S501 3 TYPICAL CAST-IN ANCHOR DETAIL No.Description Date 4 1/2"4 1/2"41/2"41/2"(4)3/4"ø F1554 GR.36 ANCHOR RODS W/ 15" EMBEDMENT 3 1/2"3 1/2"31/2"31/2"(4)3/4"ø F1554 GR.36 ANCHOR RODS W/ 9" EMBEDMENT 4"4"4"4"(4)3/4"ø F1554 GR.36 ANCHOR RODS W/ 9" EMBEDMENT 5"5"5"5"(4)1"ø F1554 GR.36 ANCHOR RODS W/ 15" EMBEDMENT 6 1/2"6 1/2"61/2"61/2"(4)1"ø F1554 GR.36 ANCHOR RODS W/ 15" EMBEDMENT 5 1/2"5 1/2"61/2"61/2"(4)1"ø F1554 GR.36 ANCHOR RODS W/ 12" EMBEDMENT 6 1/2"6 1/2"61/2"61/2"(4)1"ø F1554 GR.36 ANCHOR RODS W/ 12" EMBEDMENT 6 1/2"6 1/2"61/2"61/2"(4)3/4"ø F1554 GR.36 ANCHOR RODS W/ 12" EMBEDMENT 6 1/2"6 1/2"61/2"61/2"(4)3/4"ø F1554 GR.36 ANCHOR RODS W/ 15" EMBEDMENT www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 1 1/2" = 1'-0"3/30/201710:51:44AMS502 ANCHOR ROD LAYOUTS Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 1 1/2" = 1'-0"S502 1 LAYOUT AR1 1 1/2" = 1'-0"S502 2 LAYOUT AR2 1 1/2" = 1'-0"S502 3 LAYOUT AR3 1 1/2" = 1'-0"S502 4 LAYOUT AR4 1 1/2" = 1'-0"S502 5 LAYOUT AR5 1 1/2" = 1'-0"S502 6 LAYOUT AR6 1 1/2" = 1'-0"S502 7 LAYOUT AR7 1 1/2" = 1'-0"S502 8 LAYOUT AR8 1 1/2" = 1'-0"S502 9 LAYOUT AR9 No.Description Date AABEAM PER PLAN GIRDER PER PLAN SECTION A-A 1. 2. 3. 4. 5. SEE STRUCTURAL STEEL GENERAL NOTES FOR INFORMATION PERTAINING TO CONNECTIONS. SLAB OR ROOF DECK NOT SHOWN FOR CLARITY. REFER TO PLANS AND TYPICAL DETAILS FOR INFORMATION PERTAINING TO SLAB AND OR STEEL DECKING. DOUBLE ANGLES MAY BE EITHER SHOP WELDED OR FIELD BOLTED TO BEAM OR COLUMN AT CONTRACTOR'S OPTION. DETAIL SHOWS BOTH OPTIONS - DO NOT USE WELDS AND BOLTS IN COMBINATION. CONNECTIONS SHALL NOT BE FIELD-WELDED UNLESS SPECIFICALLY INDICATED. SEE CONNECTION SCHEDULE FOR BOLTING AND WELDING REQUIREMENTS. ADD 1/2" TO "L" DIMENSION IN SCHEDULE IF WELDED OPTION(S) USED. WHERE BEAM-TO-GIRDER CONNECTION IS A MOMENT CONNECTION, NUMBER OF BOLTS MAY BE REDUCED BY ONE BOLT IF NECESSARY FOR CONNECTIONS HAVING THREE OR MORE BOLTS. IF NUMBER OF BOLTS IS REDUCED, BOLTS IN CONNECTION SHALL BE 1" DIAMETER A490-N BOLTS THROUGH STD. DIA. HOLES. ANGLE THICKNESS SHALL ALSO BE INCREASED TO 3/8". ALL SHEAR CONNECTION CONDITIONS WHERE THIS DETAIL IS NOT APPLICABLE OR IS NOT DESIRED BY THE CONTRACTOR SHALL BE DESIGNED AND DETAILED BY THE FABRICATOR'S ENGINEER AND ONLY AFTER EXPRESSED CONSENT OF THE ENGINEER OF RECORD. NOTES: BEAM SIZE LENGTH OF ANGLES, L (IN) NUMBER OF 3/4" DIA. A325-X BOLTS W8 5 1/2"2 W10 5 1/2"2 W12 8 1/2"3 W14 W16 11 1/2"4 W18 14 1/2"5 W21 17 1/2"6 W24 W27 W30 W33 W36 W40 W44 20 1/2"7 23 1/2"8 26 1/2"9 29 1/2"10 29 1/2"10 33 1/2"11 35 1/2"12 WELD @ GDR. WEB, wa WELD @ BEAM WEB, wb 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 5/16 1/4 1/4 1/4 1/4 BEAM 3/4" DIA. A325-X BOLTS PER SCHEDULE 8 1/2"3 5/16 5/16 5/16 5/1611/4"n-1@3"41/4"wa WELDED OPTION (SEE NOTE 3) wb WELDED OPTION (SEE NOTE 3) wa 2wa WELDED OPTION (SEE NOTE 3)LGIRDER PER PLAN SHEAR CONNECTION PER TYPICAL BEAM-TO-GIRDER SHEAR CONNECTION DETAIL (SEE NOTE 2) BEAM PER PLAN BEAM PER PLAN CJP - TYP. EA. SIDE T & B WELD ACCESS HOLES PER AISC REQ'S SHEAR CONNECTION PER TYPICAL BEAM-TO-GIRDER SHEAR CONNECTION DETAIL (SEE NOTE 3) CJP - TYP. EA. SIDET & B GIRDER PER PLAN BEAM PER PLAN WELD ACCESS HOLES PER AISC REQ'S BEAM TO HSS COLUMN BEAM TO BEAM NOTE: WHEN NO REACTIONS ARE SHOWN ON THE STRUCTURAL FRAMING PLANS, DESIGN CONNECTION TO SUPPORT A MINIMUM REACTION VALUE EQUAL TO THE AISC "TABULATED ALLOWABLE UNIFORM LOAD" VALUE FOR THE GIVEN SHAPE, GRADE OF STEEL, AND SPAN LENGTH DIVIDED BY TWO FOR THE PARTICULAR BEAM IN QUESTION. IF THE BEAM IS DESIGNED AS A COMPOSITE BEAM WITH SHEAR STUDS, MULTIPLY THE REACTION VALUE BY A FACTOR OF 1.5. PLATE LENGTHS AND MINIMUM NUMBER OF BOLTS ARE LISTED BELOW. W8 W10 W12 W14 W16 W18 W21 6 6 9 9 12 15 18 2 2 3 3 4 5 6 3/8" THICK SHEAR PLATE THROUGH SLOTTED TUBE TYP.ERECTION ANGLE IF REQUIRED 3/8" SHEAR PLATE TYP. OF GIRDER W24 W27 W30 W36 W40 W44 21 24 24 30 33 36 7 8 8 10 11 12 W33 27 9 BEAM LENGTH OF PLATE, L (IN) NUMBER OF 3/4" DIA 490-N BOLTS BEAM LENGTH OF PLATE, L (IN) NUMBER OF 3/4" DIA A490-N BOLTS OF COLUMN SYMMETRICAL Ld/21/4" 1/4" TYP.1/4" 1/4" TYP.d/2LL11/2"BEAM PER PLAN COLUMN PER PLAN TYP. TOP & BOTTOM FLANGE 3/4" TOP PLATE 10"x10"x1" PLATE SHOP WELDED IN COLUMN www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR As indicated 3/30/201710:51:45AMS505 TYPICAL STEEL CONNECTION DETAILS Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 1" = 1'-0"S505 5 TYPICAL DOUBLE ANGLE SHEAR CONNECTION 1" = 1'-0"S505 1 TYPICAL BEAM TO DEEP GIRDER MOMENT CONNECTION 1" = 1'-0"S505 2 TYPICAL BEAM TO SHALLOW GIRDER MOMENT CONNECTION 3/4" = 1'-0"S505 4 TYPICAL SHEAR PLATE CONNECTION DETAIL 1" = 1'-0"S505 3 TYPICAL WIDE FLANGE BEAM TO TUBE COLUMN MOMENT CONNECTION No.Description Date SEENOTE2SUPPORTFASTENERSSEE NOTE 3 SIDELAP FASTENERS PERIMETER DECK EDGE FASTENERS TO SUPPORT (SEE NOTE 2) LAYOUT OR SPLIT DECK AS REQUIRED TO ALLOW FOR DECK FASTENING TO INTERIOR BEAMS WHICH ARE INCLUDED IN BRACED BAYS OR NOTED AS HAVING AXIAL TRANSFER CONNECTIONS AT ONE OR BOTH ENDS (DENOTED ON PLAN BY 'CX'). PROVIDE PERIMETER EDGE FASTENING PATTERN. NOTES: 1. 2. 3. SEE GENERAL NOTES AND COMPOSITE STEEL DECKING SPECIFICATION SECTION FOR ADDITIONAL INFORMATION PERTAINING TO STEEL ROOF DECKING AND ITS ATTACHMENTS. STEEL ROOF DECK FASTENERS TO STEEL FRAME SHALL BE 5/8" DIA (MIN) PUDDLE WELDS. STEEL ROOF DECK SIDELAP FASTENERS SHALL BE #10 SELF-DRILLING (TEK) SCREWS, MINIMUM. PROVIDE SIDE LAP FASTENERS AT 1/3 POINTS OR 2'-0" WHICHEVER IS LESSER. SEE NOTE 2 EOD (SEE PLAN) BENT PLATE (SEE NOTE 1) tp (SEE SCHEDULE) PLATE THICKNESS, EDGE OF DECK DIMENSION EOD < 14" tp MIN 14" > EOD < 18" 1/4" 3/8" BENT PLATE THICKENSS SHOWN IN SHEDULE IS THE VALUE TO BE USED WHEN PLATE THICKNESS IS NOT OTHERWISE NOTED IN PLAN OR DETAILS. WHEN PLATE THICKNESS LARGER THAN SCHEDULED THICKNESS IS SPECIFIED, USE THE LARGER THICKNESS WHERE DETAIL OR PLAN NOTE DESIGNATION IS APPLICABLE. BENT PLATE AT EDGE OF DECK SHALL BE FIELD INSTALLED. THE "EOD" DIMENSION REFERENCED IN PLAN IS A NOMINAL DIMENSION. DUE TO TOLERANCES IN FABRICATION AND ERECTION, THE STEEL BEAM/GIRDER MAY NOT BE EXACTLY PARALLEL TO AND CENTERED ON THE GRIDLINE DEPICTED IN THE DRAWINGS. THE BENT PLATE SHALL BE FIELD ALIGNED WITH THE ARCHITECTURAL BUILDING LINE TAKING INTO ACCOUNT ALL TOLERANCES IN FABRICATION AND ERECTION.4"TYPNOTES: 1. 2. BEAM PER PLAN ROOF DECK PER PLAN. SEE PLAN FOR SPAN DIRECTION. 3/16 2-12 PROVIDE L3x3x1/4 @ 4'-0" O.C. KICKER IF E.O.D. IS GREATER THAN 12" FASTEN PERIMETER DECK EDGES TO SUPPORT @ 12" OC TYPICAL (SEE NOTE 2) LAYOUT OR SPLIT DECK AS REQUIRED TO ALLOW FOR DECK FASTENING TO INTERIOR BEAMS WHICH ARE INCLUDED IN BRACED BAYS OR NOTED AS HAVING AXIAL TRANSFER CONNECTIONS AT ONE OR BOTH ENDS (DENOTED ON PLAN BY 'CX'). FASTENING @ 12" OC TYPICAL IN THESE CONDITIONS. SEE GENERAL NOTES AND COMPOSITE STEEL DECKING SPECIFICATION SECTION FOR ADDITIONAL INFORMATION PERTAINING TO COMPOSITE STEEL DECKING AND ITS ATTACHMENTS. COMPOSITE STEEL DECK SHALL BE FASTENED TO STEEL FRAME USING 3/4" DIA. (MIN) PUDDLE WELDS. WHERE SHEAR STUDS ARE REQUIRED ON STEEL BEAMS, SHEAR STUD WELDS MAY BE USED TO REPLACE DECK FASTENERS. WHERE CONCRETE SUPPORTS ARE PROVIDED AT BASEMENT WALLS OR OTHER SIMILAR CONDITIONS, ATTACH DECK USING POWER ACTUATED FASTENERS IF STEEL EMBED PLATE IS NOT PROVIDED. STEEL FLOOR DECK SIDELAP FASTENERS SHALL BE #10 SELF-DRILLING (TEK) SCREWS, MINIMUM. FASTEN DECK TO SUPPORTS @ 12" OC TYPICAL (SEE NOTE 2) PROVIDE SIDELAP FASTENERS AT THIRD- POINTS OF DECK SPAN, OR 3'-0", WHICHEVER IS LESS. 1. 2. 3. NOTES:BEAMSPACINGPERPLANAISC MIN. TYP. BEAM PER PLAN L4"x4"x5/16" AT COMPOSITE SLAB L3"x3"x5/16" AT METAL DECK BEAM PER PLAN NOTES: 1. 2. 3. 4. PROVIDE STEEL FRAME AROUND ALL OPENINGS WITH ANY DIMENSION 12" OR LARGER. VERIFY SIZE AND LOCATION OF OPENINGS WITH THE VARIOUS TRADES. PROVIDE STEEL FRAME AROUND THE GROUP OF ANY TWO OR MORE PIPE PENETRATIONS WITH LESS THAN 12" CLEAR BETWEEN THE PENETRATIONS. VERIFY SIZE AND LOCATION OF THE PENETRATIONS WITH THE VARIOUS TRADES. SUBMIT FRAME LAYOUTS AS COORDINATED WITH OTHER TRADES FOR SIZES AND LOCATIONS FOR A/E APPROVAL. PROVIDE STEEL FRAME AROUND ALL ROOF DRAINS REQUIRING METAL SUMP PAN. FOR NUMBER AND LOCATIONS OF ROOF DRAINS, SEE PLUMBING & ARCHL DWGS. COMPOSITE SLAB PER PLAN (SEE NOTE 2) BEAM PER PLAN 1/4 3-12 3/4" DIA. x 6" WELDED HEAD ANCHOR STUDS @ 1'-6" O.C.SEEPLANEDGE OF SLAB DIMENSION EOS < 14" tp MIN 14" > EOS < 18" 1/4" 3/8" (SEE SCHEDULE) PLATE THICKNESS, tp BENT PLATE THICKENSS SHOWN IN SHEDULE IS THE VALUE TO BE USED WHEN PLATE THICKNESS IS NOT OTHERWISE NOTED IN PLAN OR DETAILS. WHEN PLATE THICKNESS LARGER THAN SCHEDULED THICKNESS IS SPECIFIED, USE THE LARGER THICKNESS WHERE DETAIL OR PLAN NOTE DESIGNATION IS APPLICABLE. BENT PLATE AT EDGE OF DECK SHALL BE FIELD INSTALLED. THE "EOS" DIMENSION REFERENCED IN PLAN IS A NOMINAL DIMENSION. DUE TO TOLERANCES IN FABRICATION AND ERECTION, THE STEEL BEAM/GIRDER MAY NOT BE EXACTLY PARALLEL TO AND CENTERED ON THE GRIDLINE DEPICTED IN THE DRAWINGS. THE BENT PLATE SHALL BE FIELD ALIGNED WITH THE ARCHITECTURAL BUILDING LINE TAKING INTO ACCOUNT ALL TOLERANCES IN FABRICATION AND ERECTION. SEE PLAN FOR DECK SPAN DIRECTION. SLAB REINFORCING NOT SHOWN FOR CLARITY. SEE PLAN AND TYPICAL DETAILS FOR COMPOSITE SLAB REINFORCING REQUIRED. 1. 2. 3. NOTES: SEE PLAN EOS PROVIDE L3x3x1/4 @ 4'-0" O.C. KICKER IF E.O.S. IS GREATER THAN 18" www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION CO. 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR As indicated 3/30/201710:51:46AMS510 TYPICAL FLOOR FRAMING DETAILS Sun King Spirits TAC JCB 16-048 30 MARCH 2017 CONSTRUCTION DOCUMENTS 1/2" = 1'-0"S510 2 TYPICAL ROOF DECK FASTENING REQUIREMENTS 1" = 1'-0"S510 4 TYPICAL ROOF EDGE DETAIL (EOD UP TO 1'-6") 1/2" = 1'-0"S510 1 TYPICAL COMPOSITE DECK FASTENING 3/4" = 1'-0"S510 5 TYPICAL FRAMED OPENING DETAIL 1" = 1'-0"S510 3 TYPICAL SLAB EDGE DETAIL No.Description Date