HomeMy WebLinkAbout04_2017-03-30 - Sun King Distillery - CDs - DIV-21 DWGSA1 P1 P1OR A1 OH 1 2 1 P2 B P2 GENERAL FLOOR PLAN NOTES RISER OR STACK NUMBER DETAIL: B = DETAIL DESIGNATION P2 = SHEET WHERE DETAIL IS LOCATED FIRE SUPPRESSION HAZARD CLASSIFICATION AND HAZARD CLASSIFICATION GROUP SECTION: 1 = SECTION DESIGNATION P2 = SHEET WHERE DETAIL IS LOCATED EQUIPMENT REFERENCE. LETTER DESIGNATION VARIES. REFER TO SCHEDULES. EQUIPMENT, DEVICE, OR PLUMBING FIXTURE MARK. LETTER DESIGNATIONS REFER TO SCHEDULES. CONNECT TO EXISTING PLAN NOTE. APPLIES ONLY TO THE SHEET WHICH IT IS SHOWN UNLESS NOTED OTHERWISE. DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL. "UP TO" SYMBOL (ITEM ON FLOOR ABOVE) 10"10" ELEV: 8' - 0"ELEV: 8' - 0" TOE: 3' - 0" BOE: 0' - 6" APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO TOP OR BOTTOM OF EQUIPMENT, UNLESS NOTED OTHERWISE APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO CENTERLINE OF PIPE, UNLESS NOTED OTHERWISE FIRE SUPPRESSION SYMBOLS DOUBLE LINE SINGLE LINE CONCEALED PENDENT SPRINKLER FS PIV S FIRE HYDRANT FLOW SWITCH GATE VALVE OS&Y INSTITUTIONAL PENDENT SPRINKLER PENDENT SPRINKLER POST INDICATOR VALVE RECESSED PENDENT SPRINKLER SIDE WALL SPRINKLER SUPERVISED VALVE UPRIGHT SPRINKLER PIPING SYMBOLS DOUBLE LINE SINGLE LINE BOTTOM CONNECTION (45°) BRANCH TEE CONNECTION (NOTE: BULLHEAD TEE'S ARE NOT PERMITTED) DIRECTION OF PITCH DROP ELBOW DOWN ELBOW UP EXISTING PIPE TO BE REMOVED EXISTING PIPE TO REMAIN FLOW DIRECTION DESIGNATION PUMP RISE TOP CONNECTION (45°) TOP CONNECTION (90°) BOTTOM CONNECTION (90°) DD RR SPECIALTY GAS SYMBOLS AIR OUTLET - LAB TYPE VC VC CARBON DIOXIDE OUTLET - HOSPITAL TYPE MEDICAL AIR OUTLET - HOSPITAL TYPE MEDICAL VACUUM INLET - HOSPITAL TYPE NITROGEN OUTLET - HOSPITAL TYPE NITROUS OXIDE OUTLET - HOSPITAL TYPE OXYGEN OUTLET - HOSPITAL TYPE WAGD INLET - HOSPITAL TYPE NATURAL GAS OUTLET - LAB TYPE VACUUM OUTLET - LAB TYPE VACUUM CLEANING STATION - WALL VACUUM CLEANING STATION - FLOOR PLUMBING AND FIRE SUPPRESSION PIPING DESIGNATIONS DOMESTIC COLD WATER DOMESTIC HOT WATER DOMESTIC HOT WATER RETURN EXISTING PIPE TO REMAIN EXISTING PIPE TO BE REMOVED HOT WATER PIPE (140 DEGS. F.) HOT WATER PIPE (180 DEGS. F.) HOT WATER RETURN PIPE (140 DEGS. F.) HOT WATER RETURN PIPE (180 DEGS. F.) ARGON PIPE COMPRESSED AIR PIPE MEDICAL CARBON DIOXIDE PIPE COMBINATION FIRE SUPPRESSION AND DOMESTIC WATER SERVICE DIESEL FUEL PIPE SPRINKLER PIPE (DRY) FIRE SUPPRESSION (STANDPIPE / SPRINKLER MAIN) FIRE SERVICE FUEL OIL FLOW LINE FUEL OIL GAUGE LINE FUEL OIL RETURN LINE FUEL OIL SUPPLY LINE NATURAL GAS PIPE GARAGE DRAINAGE PIPE GAS SERVICE HYDROGEN PIPE HELIUM PIPE MEDICAL INSTRUMENT AIR PIPE KITCHEN WASTE PIPE LABORATORY COMPRESSED AIR PIPE LABORATORY VENT PIPE LABORATORY VACUUM PIPE LABORATORY WASTE PIPE MEDICAL NITROGEN PIPE MEDICAL COMPRESSED AIR PIPE MEDICAL-SURGICAL VACUUM PIPE GASOLINE PIPE (NON-LEAD) MEDICAL NITROUS OXIDE PIPE NON-POTABLE MEDICAL OXYGEN PIPE (OVERFLOW) SECONDARY STORM DRAINAGE PIPE PROPANE GAS PIPE PUMP DISCHARGE PIPE PRE-ACTION / DELUGE SPRINKLER PIPE PURE WATER PIPE SPRINKLER PIPE (WET) SANITARY DRAINAGE PIPE SOFT COLD WATER SPRINKLER DRAIN PIPE STORM DRAINAGE PIPE FUEL TANK VENT PIPE TRAP PRIMER DISCHARGE PIPE TEMPERED WATER PIPE SANITARY SEWER VENT WASTE ANESTHESIA GAS DISPOSAL PIPE WATER SERVICE 140 LV 180 140R 180R AR CA CO2 CWS DF DS F FS FOF FOG FOR FOS G GD GS H2 HE IA IV IW LA LV LW N2 MA MV NG NO NPW O2 OD P PD PS PW S SAN SCW SD STM T TP TW V WAGD WS INDIRECT VENT PIPE INDIRECT WASTE PIPE K 3 3 CHECK VALVE T P FOB FOT SHUTOFF VALVE (REFER TO SPECIFICATIONS FOR REQUIRED TYPE BASED ON APPLICATIONS) CONCENTRIC PIPE REDUCER ECCENTRIC PIPE REDUCER PRESSURE GAUGE TEMPERATURE GAUGE OR THERMOMETER UNION CLEANOUT STRAINER STRAINER WITH A BLOW DOWN VALVE AND HOSE CONNECTION DRAIN VALVE WITH HOSE END CONNECTION AUTOMATIC FLOW CONTROLLER WITH P/T PLUG IN AND OUT EXPANSION JOINT PRESSURE REGULATING VALVE SAFETY RELIEF VALVE. PIPE DISCHARGE AIR GAPPED TO FLOOR DRAIN UNLESS NOTED OTHERWISE. PRESSURE AND TEMPERATURE TEST PLUG TRAP PRIMER VACUUM GAUGE WITH STOP CLEANOUT TO GRADE OR FINISHED FLOOR END CAP MIXING FAUCET PLUG HOSE BIB WALL HYDRANT PLUG VALVE SHUTOFF VALVE AND BOX SHUTOFF VALVE ON RISER V TP CO COMBINATION SHUTOFF AND BALANCING VALVE (REFER TO SPECIFICATIONS FOR REQUIRED TYPE BASED ON APPLICATIONS) BALL VALVE BUTTERFLY VALVE GATE VALVE VALVES AND FITTINGS DOUBLE LINE SINGLE LINE SOLENOID VALVES P/T PRESSURE AND TEMPERATURE SAFETY RELIEF VALVE. PIPE DISCHARGE AIR GAPPED TO FLOOR DRAIN UNLESS NOTED OTHERWISE. FIRE DEPARTMENT VALVE WATER METERM ACID VENT PIPEAV ACID WASTE PIPEAW ABBREVIATIONS AAP - AREA ALARM PANEL (MEDICAL GAS) AC - AIR COMPRESSOR OR AIR CONDITIONER ACC - ACCESS ACCU - AIR COOLED CONDENSING UNIT AD - ACCESS DOOR OR AREA DRAIN ADB - ACID DILUTION BASIN ADJ - ADJUSTABLE AFF - ABOVE FINISHED FLOOR AFG - ABOVE FINISHED GRADE ALT - ALTERNATE AP - ACCESS PANEL APPROX - APPROXIMATE AR - AIR RECEIVER OR ARGON ARCH - ARCHITECT OR ARCHITECTURAL ASSY - ASSEMBLY AV - ACID VENT AW - ACID WASTE BDD - BACK DRAFT DAMPER BFP - BACKFLOW PREVENTER BLDG - BUILDING BOB - BOTTOM OF BEAM BOD - BOTTOM OF DUCT BOE - BOTTOM OF EQUIPMENT BOF - BOTTOM OF FOOTING BOG - BOTTOM OF GRILLE BOP - BOTTOM OF PIPE BOT - BOTTOM BT - BATHTUB BTU - BRITISH THERMAL UNIT BTUH - BRITISH THERMAL UNIT PER HOUR BTWN - BETWEEN CA - COMPRESSED AIR CB - CATCH BASIN CBD - COUNTER BALANCED BACKDRAFT DAMPER CFCI - CONTRACTOR FURNISHED CONTRACTOR INSTALLED CFM - CUBIC FEET PER MINUTE CHS - CHILLED WATER SUPPLY CHR - CHILLED WATER RETURN CI - CAST IRON CK - CLINICAL SINK CLG - CEILING CMU - CONCRETE MASONRY UNIT CO - CLEAN OUT CO2 - MEDICAL CARBON DIOXIDE CONN - CONNECT OR CONNECTION CONTR - CONTRACTOR CORR - CORRIDOR CS - CLINICAL SINK OR COLD SOFT WATER CTR - CENTER CU - COPPER CW - COLD WATER CWS - COMBINATION WATER SERVICE OR CONDENSER WATER SUPPLY CWR - CONDENSER WATER RETURN D - DEPTH OR DRAIN LINE DD - DECK DRAIN DET - DETAIL DF - DRINKING FOUNTAIN OR WATER COOLER OR DIESEL FUEL DFU - DRAINAGE FIXTURE UNIT DI - DEIONIZED WATER DIA - DIAMETER DIM - DIMENSION DN - DOWN DS - DOWN SPOUT OR SPRINKLER (DRY) DT - PERFORATED DRAIN TILE DWG - DRAWING EA - EACH EC - ELECTRICAL CONTRACTOR (DIVISION 26) EEW - EMERGENCY EYE WASH EJ - EXPANSION JOINT ELEC - ELECTRICAL ELEV - ELEVATOR EQ - EQUAL EQUIP - EQUIPMENT ET - EXPANSION TANK ETR - EXISTING TO REMAIN ES - EMERGENCY SHOWER EQS - EQUIPMENT SUPPLIER EWC - ELECTRICAL WATER COOLER EXH - EXHAUST AIR EXP - EXPANSION EXT - EXTERIOR EX - EXISTING F - FIRE SUPPRESSION (STANDPIPE/SPRINKLER MAIN) FCE - FIRE CONTROL EQUIPMENT FCO - FLOOR CLEANOUT FD - FLOOR DRAIN FDC - FIRE DEPARTMENT CONNECTION FDV - FIRE DEPARTMENT VALVE FF - FINISHED FLOOR ELEVATION FHC - FIRE HOSE CABINET FLR - FLOOR FM - FORCE MAIN FOB - FLAT ON BOTTOM FOF - FUEL OIL FLOW FOG - FUEL OIL GAUGE FOR - FUEL OIL RETURN FOS - FUEL OIL SUPPLY FOT - FLAT ON TOP FPM - FEET PER MINUTE FR - FIRE RISER FS - FLOOR SINK OR FIRE SERVICE FSC - FIRE SUPPRESSION CONTRACTOR (DIVISION 21) FT - FEET FTG - FOOTING G - GAS OR NATURAL GAS GA - GAUGE GAL - GALLON GALV - GALVANIZED GC - GENERAL TRADES CONTRACTOR GD - GARAGE DRAINAGE GPM - GALLONS PER MINUTE GS - GAS SERVICE GW - GREASE WASTE H2 - HYDROGEN HB - HOSE BIBB HC - HVAC CONTRACTOR (DIVISION 23) HD - HUB DRAIN HE - HELIUM HG - REFRIGERANT HOT GAS HP - HORSEPOWER OR HIGH POINT HPC - HIGH PRESSURE CONDENSATE RETURN HPS - HIGH PRESSURE STEAM SUPPLY HPW - HIGH PURITY WATER HPWR - HIGH PURITY WATER RETURN HR - HOSE REEL HT - HEAT TRACE HTR - HEATER HVAC - HEATING, VENTILATING, AND AIR CONDITIONING HW - HOT WATER HWR - HEATING HOT WATER RETURN HWS - HEATING HOT WATER SUPPLY IA - MEDICAL INSTRUMENT AIR ID - INSIDE DIAMETER INV - INVERT ELEVATION IN - INCHES IV - INDIRECT VENT IW - INDIRECT WASTE JS - JANITOR SINK K - KITCHEN WASTE KEC - KITCHEN EQUIPMENT CONTRACTOR K - KITCHEN WASTE KEC - KITCHEN EQUIPMENT CONTRACTOR L - LENGTH LA - LABORATORY COMPRESSED AIR LAV - LAVATORY LBS - POUNDS LCW - LABORATORY COLD WATER LEC - LABORATORY EQUIPMENT CONTRACTOR LHW - LABORATORY HOT WATER LHWR - LABORATORY HOT WATER RETURN LPC - LOW PRESSURE CONDENSATE RETURN LPS - LOW PRESSURE STEAM SUPPLY LV - LABORATORY VACUUM OR LABORATORY VENT LW - LABORATORY WASTE MA - MEDICAL COMPRESSED AIR MAP - MASTER ALARM PANEL (MEDICAL GAS) MAX - MAXIMUM MB - MOP BASIN MC - MECHANICAL CONTRACTOR (DIVISION 23) MEZZ - MEZZANINE MFR - MANUFACTURER MH - MANHOLE MIN - MINIMUM OR MINUTE MISC - MISCELLANEOUS MTD - MOUNTED MTG - MOUNTING MPC - MEDIUM PRESSURE CONDENSATE RETURN MPS - MEDIUM PRESSURE STEAM SUPPLY MU - WATER MAKE-UP MV - MEDICAL SURGICAL VACUUM N2 - MEDICAL NITROGEN NG - GASOLINE (NON-LEAD) NIC - NOT IN CONTRACT NO - MEDICAL NITROUS OXIDE NOM - NOMINAL NPW - NON-POTABLE WATER NPT - NATIONAL PIPE THREAD NTS - NOT TO SCALE 02 - MEDICAL OXYGEN OA - OUTDOOR AIR OD - OUTSIDE DIAMETER OR OVERFLOW DRAIN OFCI - OWNER FURNISHED CONTRACTOR INSTALLED OFOI - OWNER FURNISHED OWNER INSTALLED P - PROPANE GAS PC - PLUMBING CONTRACTOR (DIVISION 22) OR PUMPED CONDENSATE RETURN PD - PUMP DISCHARGE OR PARAPET DRAIN PIV - POST INDICATOR VALVE PLBG - PLUMBING PS - PRE-ACTION/DELUGE SPRINKLER PRESS - PRESSURE PRV - PRESSURE REGULATING VALVE PSF - POUNDS PER SQUARE FOOT PSI - POUNDS PER SQUARE INCH PSV - PRESSURE SUSTAINING VALVE PSIG - POUNDS PER SQUARE INCH GAUGE PW - PURE WATER RA - RETURN AIR RAD - RADIUS RCP - REINFORCED CONCRETE PIPE RD - ROOF DRAIN REC - RECESSED REQD - REQUIRED RI - ROUGH IN RL - REFRIGERANT LIQUID ROS - REVERSE OSMOSIS WATER SUPPLY ROR - REVERSE OSMOSIS WATER RETURN RPM - REVOLUTIONS PER MINUTE RS - REFRIGERANT SUCTION RV - RELIEF VALVE S - SPRINKLER (WET) SA - SHOCK ARRESTOR OR SUPPLY AIR SAN - SANITARY OR SANITARY DRAIN SCH - SCHEDULE SCW - SOFT COLD WATER SD - SPRINKLER DRAIN OR SUBSOIL DRAIN SH - SHOWER SHT - SHEET SK - SINK SPEC - SPECIFICATIONS SQ - SQUARE SR - SUPPLY RISER SS - SANITARY STACK (SOIL OR WASTE) OR STAINLESS STEEL STD - STANDARD STM - STORM OR STORM DRAINAGE STRUC - STRUCTURAL OR STRUCTURE SUC - SITE UTILITY CONTRACTOR T - FUEL TANK VENT TD - TRENCH DRAIN TEMP - TEMPERATURE TOB - TOP OF BEAM TOD - TOP OF DUCT TOE - TOP OF EQUIPMENT TOF - TOP OF FOOTING TOJ - TOP OF JOIST TOP - TOP OF PIPE TOS - TOP OF SLAB OR TOP OF STEEL TF - TRAP FILLER TP - TRAP PRIMER OR TRAP PRIMER DISCHARGE TW - TEMPERED WATER TYP - TYPICAL UR - URINAL UNO - UNLESS NOTED OTHERWISE V - VENT OR SANITARY SEWER VENT VAC - VACUUM VC - VACUUM CLEANING VCV - VACUUM CLEANING VALVE VE - VACUUM EXHAUST VEL - VELOCITY VIB - VALVE IN BOX VOL - VOLUME VP - VACUUM PUMP VS - VENT STACK VTR - VENT THROUGH ROOF VR - VENT RISER W/ - WITH W/0 - WITHOUT W - WASTE WAGD - WASTE ANESTHESIA GAS DISPOSAL WC - WATER CLOSET WCO - WALL CLEANOUT WH - WALL HYDRANT OR WATER HEATER WIV - WALL INDICATOR VALVE WS - WATER SERVICE YCO - YARD CLEANOUT ZVC - ZONE VALVE CABINET PIPE RISER NOTE: ALL SYMBOLS AND ABBREVIATIONS ARE SUBJECT TO MODIFICATIONS ON OTHER DRAWINGS. ALL SYMBOLS OR ABBREVIATIONS MIGHT NOT NECESSARILY BE USED ON THIS PROJECT. www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 11:07:44 AMFS000 SYMBOLS, ABBREVIATIONS, INDEX Sun King Spirits RGF RGF 16-048 CONSTRUCTION DOCUMENTSBP2 PROJECT STATUSBP3 PROJECT STATUSBP4 PROJECT STATUSBP5 PROJECT STATUSBP6 PROJECT STATUS 30 MARCH 201730 MARCH 201730 MARCH 2017 FIRE SUPPRESSION SHEET LIST Sheet Number Sheet Name FS000 SYMBOLS, ABBREVIATIONS, INDEX FS100 FIRE SUPPRESSION PLANS HYDRANT FLOW TEST DATA: STATIC - 55 PSI RESIDUAL - 35 PSI FLOW - 1000 GPM No. Description Date A B C C.4 D E.7 11.2 1.4 2 2.4 3 4 5 6 Mill Room 121 Water 110 Food 1 120 JNTR CLST 119 Distillery 104 Freezer 109 Cooler 108 Cooler 107 Food 3 114 Hall 118 RR 116 RR 117 Hall 106 STAIR 112 STORAGE 105 Bar 102 Retail 122 Bar 103 Elec. 111 Food 2 115 Dining 101 Kitchen 113 VESTIBULE 100 Info 54 3 FS100 FS FS3 3 3 2 OH 2 OH 1 OH 1 OH 1 OH 1 OH 2 OH 1 1 SS SFS A B C C.4 D E.7 11.2 1.4 2 2.4 3 4 5 6 RR 212 PIZZA OVEN 216 HALL 206 BOILER ROOM 207 RR 204 RR 205 STAFF BREAK 211 CATERING PREP 214 SUPPORT 215 JAN 208 OFFICE 210 CATERING ALCOVE 63 BAR 201 DECK 202 PRIVATE FUNCTION 203 DINING 200 STAIR 213Hall 209 OH 1 OH 1 OH 1 4 S S5 1 2 4 2 3 1 1 2 1 2 90 ELL PLUG 45 ELL45 ELL UNDISTURBED EARTH SURFACE CONCRETE PAD - SEE SCHEDULE PLUG TWO - 1.5" THICK OAK BLOCKS PIPE SIZE 90 ELL 45 ELL TEE & PLUG 3" 4" 6" 8" 10" 1.5" 2" 3" 4" 8" 1" 1"1.5"2"5" 1"1.5"2"8"7" (APPROX. ONE CU.FT. CONCRETE/SQ.FT. BEARING AREA) EARTH BEARING AREA - SQ. FT. 1 2 3 4 FIRE MAIN F FS SIGNAL WIRING IN CONDUIT TO ALARM BELL ON WALL OF BLDG. WATER FLOW SWITCH FURNISHED AND WIRED SWING CHECK VALVE MAIN DRAIN VALVE MAIN DRAIN & TEST LINE FLOOR FLANGE-TYPICAL SLEEVE THRU FOUNDATION WALL FOOTING FIRE SUPPRESSION SERVICE EXTERIOR WALL SWING CHECK VALVE PRESSURE GAUGE SLEEVE THRU WALL, CAULK WEATHER TIGHT SPLASH BLOCK GRADE P P S FSROUTE TO FDC. REFER TO CIVIL DWGS www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 11:07:49 AMFS100 FIRE SUPPRESSION PLANS Sun King Spirits RGF RGF 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 SCALE: 1/8" = 1'-0" FIRST FLOOR FIRE SUPPRESSION PLAN1 SCALE: 1/8" = 1'-0" SECOND FLOOR FIRE SUPPRESSION2 SCALE: NONE UNDER GROUND WATER PIPE THRUST BLOCKS4 A. ALL PIPING IS ABOVE THE CEILING (AT THE UNDERSIDE OF STRUCTURE IN EXPOSED STRUCTURAL AREAS) UNLESS OTHERWISE INDICATED. B. REFER TO ARCHITECTURAL DRAWINGS FOR REFLECTED CEILING PLANS AND GENERAL TRADES CONSTRUCTION INFORMATION. COORDINATE SPRINKLER LOCATIONS WITH CEILING DEVICES (LIGHTING, GRILLES, ETC.) OBTAIN ARCHITECTS APPROVAL OF SPRINKLER LAYOUT PRIOR TO INSTALLATION. FINAL FINISHED APPEARANCE OF WORK MUST BE APPROVED BY THE ARCHITECT. C. TOTAL SQUARE FOOTAGE OF PROJECT IS 16,300 SQUARE FEET. MAXIMUM PER FLOOR SQUARE FOOTAGE IS 20,000 SQUARE FEET. TOTAL NUMBER OF FIRE RISERS REQUIRED 1. D. CONTRACTOR SHALL MAKE REQUIRED FLOW TESTS, LAY OUT SYSTEMS, OBTAIN APPROVALS FROM THE AUTHORITY HAVING JURISDICTION AND THE OWNER’S INSURER PRIOR TO BEGINNING ANY FABRICATION OR INSTALLATION WORK. E. FIRE SUPPRESSION SPRINKLER SYSTEMS. REFER TO DRAWING AND SPECIFICATIONS FOR COMPLETE SCOPE OF WORK. 1 FIRE SUPPRESSION CONTRACTOR SHALL DESIGN AND INSTALL AUTOMATIC SPRINKLER SYSTEMS AND SUPERVISORY ALARM SYSTEM FOR THE ENTIRE BUILDING. BUILDING TO BE TOTALLY FIRE SUPPRESSED. F. BASIS FOR DESIGN OF FIRE SUPPRESSION SYSTEM(S) TO BE: 1. LIGHT HAZARD 1500 SQUARE FEET, 0.10 GPM/SQ. FT., 225 SQUARE FEET MAXIMUM PER SPRINKLER. 100 GPM HOSE STREAM ALLOWANCE. 2. ORDINARY HAZARD, (GROUP 1) 1500 SQUARE FEET, 0.15 GPM/SQ. FT., 130 SQUARE FEET MAXIMUM PER SPRINKLER. 250 GPM HOSE STREAM ALLOWANCE. AREA OF OPERATION REDUCTIONS AND INCREASES SHALL BE CALCULATED PER NFPA STANDARDS. VERIFY DENSITIES WITH GOVERNING AUTHORITIES AND OWNER’S INSURER BEFORE PROCEEDING WITH DESIGN OF SYSTEM(S). IF GOVERNING AUTHORITIES OR OWNER’S INSURER REQUIREMENTS ARE MORE STRINGENT THOSE REQUIREMENTS SHALL PREVAIL. ALL AREAS ARE TO BE LIGHT HAZARD CLASSIFICATION, UNLESS OTHERWISE INDICATED ON THE PLANS OR REQUIRED BY THE GOVERNING AUTHORITY. G. PROVIDE THE FOLLOWING SPRINKLER TYPES, UNLESS OTHERWISE NOTED ON THE DRAWINGS. PENDENT TYPE SPRINKLERS SHALL BE LOCATED IN THE CENTER OF SQUARE PADS AND AT THE CENTER OR AT QUARTERPOINTS OF THE LONG AXIS OF RECTANGULAR PADS. 1. SPRINKLERS IN PUBLIC AREAS WITH CEILINGS SHALL BE CONCEALED TWO PIECE ADJUSTABLE PENDENT QUICK RESPONSE TYPE WITH WHITE FINISH COVERPLATE. 2. SPRINKLERS IN EXPOSED AREAS SHALL BE QUICK RESPONSE BRASS UPRIGHT TYPE. H. ALL PIPING SHOWN (WITH SIZES) SHALL BE INSTALLED AS SIZED UNLESS HYDRAULIC CALCULATIONS INDICATED A LARGER SIZE IS NECESSARY. FOR PIPING NOT SHOWN OR SIZED ON THE DRAWINGS, PIPE SIZING SHALL BE BASED ON FIRE SUPPRESSION CONTRACTORS HYDRAULIC CALCULATIONS. I. EXERCISE SPECIAL CARE TO COORDINATE PIPING AND EQUIPMENT LOCATIONS WITH ALL OTHER TRADES. FIRE SUPPRESSION DESING NOTES 1 ROUTE 6" FS TO FDC. INSTALL BALL DRIP AND ROUTE TO EXTERIOR. SEAL WALL PENETRATION WEATHER TIGHT. REFER TO CIVIL DRAWINGS FOR CONTINUATION. 2 NO PIPING TO BE ROUTED OVER THIS AREA OTHER THEN WHAT SERVES THIS AREA. 3 PROVIDE DRY TYPE SPRINKLER HEADS TO SERVCE COOLER/FREEZER. 4 DRY PIPE SYSTE TO SERVE PERGOLA. ROUTE DRY PIPING WITHIN CAN LIGHT TRACK. (WORK AS PART OF ALTERNATE BID). 5 FS DRY PIPE VALVE. ROUTE DRAIN TO ADJACENT MOP BASIN. NOTES SCALE: NONE FIRE RISER - W/PUMPER CONNECTION3 No. Description Date