HomeMy WebLinkAbout05_2017-03-30 - Sun King Distillery - CDs - DIV-22 DWGSA1 P1 P1OR A1 OH 1 2 1 P2 B P2 GENERAL FLOOR PLAN NOTES RISER OR STACK NUMBER DETAIL: B = DETAIL DESIGNATION P2 = SHEET WHERE DETAIL IS LOCATED FIRE SUPPRESSION HAZARD CLASSIFICATION AND HAZARD CLASSIFICATION GROUP SECTION: 1 = SECTION DESIGNATION P2 = SHEET WHERE DETAIL IS LOCATED EQUIPMENT REFERENCE. LETTER DESIGNATION VARIES. REFER TO SCHEDULES. EQUIPMENT, DEVICE, OR PLUMBING FIXTURE MARK. LETTER DESIGNATIONS REFER TO SCHEDULES. CONNECT TO EXISTING PLAN NOTE. APPLIES ONLY TO THE SHEET WHICH IT IS SHOWN UNLESS NOTED OTHERWISE. DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL. "UP TO" SYMBOL (ITEM ON FLOOR ABOVE) 10"10" ELEV: 8' - 0"ELEV: 8' - 0" TOE: 3' - 0" BOE: 0' - 6" APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO TOP OR BOTTOM OF EQUIPMENT, UNLESS NOTED OTHERWISE APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO CENTERLINE OF PIPE, UNLESS NOTED OTHERWISE FIRE SUPPRESSION SYMBOLS DOUBLE LINE SINGLE LINE CONCEALED PENDENT SPRINKLER FS PIV S FIRE HYDRANT FLOW SWITCH GATE VALVE OS&Y INSTITUTIONAL PENDENT SPRINKLER PENDENT SPRINKLER POST INDICATOR VALVE RECESSED PENDENT SPRINKLER SIDE WALL SPRINKLER SUPERVISED VALVE UPRIGHT SPRINKLER PIPING SYMBOLS DOUBLE LINE SINGLE LINE BOTTOM CONNECTION (45°) BRANCH TEE CONNECTION (NOTE: BULLHEAD TEE'S ARE NOT PERMITTED) DIRECTION OF PITCH DROP ELBOW DOWN ELBOW UP EXISTING PIPE TO BE REMOVED EXISTING PIPE TO REMAIN FLOW DIRECTION DESIGNATION PUMP RISE TOP CONNECTION (45°) TOP CONNECTION (90°) BOTTOM CONNECTION (90°) DD RR SPECIALTY GAS SYMBOLS AIR OUTLET - LAB TYPE VC VC CARBON DIOXIDE OUTLET - HOSPITAL TYPE MEDICAL AIR OUTLET - HOSPITAL TYPE MEDICAL VACUUM INLET - HOSPITAL TYPE NITROGEN OUTLET - HOSPITAL TYPE NITROUS OXIDE OUTLET - HOSPITAL TYPE OXYGEN OUTLET - HOSPITAL TYPE WAGD INLET - HOSPITAL TYPE NATURAL GAS OUTLET - LAB TYPE VACUUM OUTLET - LAB TYPE VACUUM CLEANING STATION - WALL VACUUM CLEANING STATION - FLOOR PLUMBING AND FIRE SUPPRESSION PIPING DESIGNATIONS DOMESTIC COLD WATER DOMESTIC HOT WATER DOMESTIC HOT WATER RETURN EXISTING PIPE TO REMAIN EXISTING PIPE TO BE REMOVED HOT WATER PIPE (140 DEGS. F.) HOT WATER PIPE (180 DEGS. F.) HOT WATER RETURN PIPE (140 DEGS. F.) HOT WATER RETURN PIPE (180 DEGS. F.) ARGON PIPE COMPRESSED AIR PIPE MEDICAL CARBON DIOXIDE PIPE COMBINATION FIRE SUPPRESSION AND DOMESTIC WATER SERVICE DIESEL FUEL PIPE SPRINKLER PIPE (DRY) FIRE SUPPRESSION (STANDPIPE / SPRINKLER MAIN) FIRE SERVICE FUEL OIL FLOW LINE FUEL OIL GAUGE LINE FUEL OIL RETURN LINE FUEL OIL SUPPLY LINE NATURAL GAS PIPE GARAGE DRAINAGE PIPE GAS SERVICE HYDROGEN PIPE HELIUM PIPE MEDICAL INSTRUMENT AIR PIPE KITCHEN WASTE PIPE LABORATORY COMPRESSED AIR PIPE LABORATORY VENT PIPE LABORATORY VACUUM PIPE LABORATORY WASTE PIPE MEDICAL NITROGEN PIPE MEDICAL COMPRESSED AIR PIPE MEDICAL-SURGICAL VACUUM PIPE GASOLINE PIPE (NON-LEAD) MEDICAL NITROUS OXIDE PIPE NON-POTABLE MEDICAL OXYGEN PIPE (OVERFLOW) SECONDARY STORM DRAINAGE PIPE PROPANE GAS PIPE PUMP DISCHARGE PIPE PRE-ACTION / DELUGE SPRINKLER PIPE PURE WATER PIPE SPRINKLER PIPE (WET) SANITARY DRAINAGE PIPE SOFT COLD WATER SPRINKLER DRAIN PIPE STORM DRAINAGE PIPE FUEL TANK VENT PIPE TRAP PRIMER DISCHARGE PIPE TEMPERED WATER PIPE SANITARY SEWER VENT WASTE ANESTHESIA GAS DISPOSAL PIPE WATER SERVICE 140 LV 180 140R 180R AR CA CO2 CWS DF DS F FS FOF FOG FOR FOS G GD GS H2 HE IA IV IW LA LV LW N2 MA MV NG NO NPW O2 OD P PD PS PW S SAN SCW SD STM T TP TW V WAGD WS INDIRECT VENT PIPE INDIRECT WASTE PIPE K 3 3 CHECK VALVE T P FOB FOT SHUTOFF VALVE (REFER TO SPECIFICATIONS FOR REQUIRED TYPE BASED ON APPLICATIONS) CONCENTRIC PIPE REDUCER ECCENTRIC PIPE REDUCER PRESSURE GAUGE TEMPERATURE GAUGE OR THERMOMETER UNION CLEANOUT STRAINER STRAINER WITH A BLOW DOWN VALVE AND HOSE CONNECTION DRAIN VALVE WITH HOSE END CONNECTION AUTOMATIC FLOW CONTROLLER WITH P/T PLUG IN AND OUT EXPANSION JOINT PRESSURE REGULATING VALVE SAFETY RELIEF VALVE. PIPE DISCHARGE AIR GAPPED TO FLOOR DRAIN UNLESS NOTED OTHERWISE. PRESSURE AND TEMPERATURE TEST PLUG TRAP PRIMER VACUUM GAUGE WITH STOP CLEANOUT TO GRADE OR FINISHED FLOOR END CAP MIXING FAUCET PLUG HOSE BIB WALL HYDRANT PLUG VALVE SHUTOFF VALVE AND BOX SHUTOFF VALVE ON RISER V TP CO COMBINATION SHUTOFF AND BALANCING VALVE (REFER TO SPECIFICATIONS FOR REQUIRED TYPE BASED ON APPLICATIONS) BALL VALVE BUTTERFLY VALVE GATE VALVE VALVES AND FITTINGS DOUBLE LINE SINGLE LINE SOLENOID VALVES P/T PRESSURE AND TEMPERATURE SAFETY RELIEF VALVE. PIPE DISCHARGE AIR GAPPED TO FLOOR DRAIN UNLESS NOTED OTHERWISE. FIRE DEPARTMENT VALVE WATER METERM ACID VENT PIPEAV ACID WASTE PIPEAW ABBREVIATIONS AAP - AREA ALARM PANEL (MEDICAL GAS) AC - AIR COMPRESSOR OR AIR CONDITIONER ACC - ACCESS ACCU - AIR COOLED CONDENSING UNIT AD - ACCESS DOOR OR AREA DRAIN ADB - ACID DILUTION BASIN ADJ - ADJUSTABLE AFF - ABOVE FINISHED FLOOR AFG - ABOVE FINISHED GRADE ALT - ALTERNATE AP - ACCESS PANEL APPROX - APPROXIMATE AR - AIR RECEIVER OR ARGON ARCH - ARCHITECT OR ARCHITECTURAL ASSY - ASSEMBLY AV - ACID VENT AW - ACID WASTE BDD - BACK DRAFT DAMPER BFP - BACKFLOW PREVENTER BLDG - BUILDING BOB - BOTTOM OF BEAM BOD - BOTTOM OF DUCT BOE - BOTTOM OF EQUIPMENT BOF - BOTTOM OF FOOTING BOG - BOTTOM OF GRILLE BOP - BOTTOM OF PIPE BOT - BOTTOM BT - BATHTUB BTU - BRITISH THERMAL UNIT BTUH - BRITISH THERMAL UNIT PER HOUR BTWN - BETWEEN CA - COMPRESSED AIR CB - CATCH BASIN CBD - COUNTER BALANCED BACKDRAFT DAMPER CFCI - CONTRACTOR FURNISHED CONTRACTOR INSTALLED CFM - CUBIC FEET PER MINUTE CHS - CHILLED WATER SUPPLY CHR - CHILLED WATER RETURN CI - CAST IRON CK - CLINICAL SINK CLG - CEILING CMU - CONCRETE MASONRY UNIT CO - CLEAN OUT CO2 - MEDICAL CARBON DIOXIDE CONN - CONNECT OR CONNECTION CONTR - CONTRACTOR CORR - CORRIDOR CS - CLINICAL SINK OR COLD SOFT WATER CTR - CENTER CU - COPPER CW - COLD WATER CWS - COMBINATION WATER SERVICE OR CONDENSER WATER SUPPLY CWR - CONDENSER WATER RETURN D - DEPTH OR DRAIN LINE DD - DECK DRAIN DET - DETAIL DF - DRINKING FOUNTAIN OR WATER COOLER OR DIESEL FUEL DFU - DRAINAGE FIXTURE UNIT DI - DEIONIZED WATER DIA - DIAMETER DIM - DIMENSION DN - DOWN DS - DOWN SPOUT OR SPRINKLER (DRY) DT - PERFORATED DRAIN TILE DWG - DRAWING EA - EACH EC - ELECTRICAL CONTRACTOR (DIVISION 26) EEW - EMERGENCY EYE WASH EJ - EXPANSION JOINT ELEC - ELECTRICAL ELEV - ELEVATOR EQ - EQUAL EQUIP - EQUIPMENT ET - EXPANSION TANK ETR - EXISTING TO REMAIN ES - EMERGENCY SHOWER EQS - EQUIPMENT SUPPLIER EWC - ELECTRICAL WATER COOLER EXH - EXHAUST AIR EXP - EXPANSION EXT - EXTERIOR EX - EXISTING F - FIRE SUPPRESSION (STANDPIPE/SPRINKLER MAIN) FCE - FIRE CONTROL EQUIPMENT FCO - FLOOR CLEANOUT FD - FLOOR DRAIN FDC - FIRE DEPARTMENT CONNECTION FDV - FIRE DEPARTMENT VALVE FF - FINISHED FLOOR ELEVATION FHC - FIRE HOSE CABINET FLR - FLOOR FM - FORCE MAIN FOB - FLAT ON BOTTOM FOF - FUEL OIL FLOW FOG - FUEL OIL GAUGE FOR - FUEL OIL RETURN FOS - FUEL OIL SUPPLY FOT - FLAT ON TOP FPM - FEET PER MINUTE FR - FIRE RISER FS - FLOOR SINK OR FIRE SERVICE FSC - FIRE SUPPRESSION CONTRACTOR (DIVISION 21) FT - FEET FTG - FOOTING G - GAS OR NATURAL GAS GA - GAUGE GAL - GALLON GALV - GALVANIZED GC - GENERAL TRADES CONTRACTOR GD - GARAGE DRAINAGE GPM - GALLONS PER MINUTE GS - GAS SERVICE GW - GREASE WASTE H2 - HYDROGEN HB - HOSE BIBB HC - HVAC CONTRACTOR (DIVISION 23) HD - HUB DRAIN HE - HELIUM HG - REFRIGERANT HOT GAS HP - HORSEPOWER OR HIGH POINT HPC - HIGH PRESSURE CONDENSATE RETURN HPS - HIGH PRESSURE STEAM SUPPLY HPW - HIGH PURITY WATER HPWR - HIGH PURITY WATER RETURN HR - HOSE REEL HT - HEAT TRACE HTR - HEATER HVAC - HEATING, VENTILATING, AND AIR CONDITIONING HW - HOT WATER HWR - HEATING HOT WATER RETURN HWS - HEATING HOT WATER SUPPLY IA - MEDICAL INSTRUMENT AIR ID - INSIDE DIAMETER INV - INVERT ELEVATION IN - INCHES IV - INDIRECT VENT IW - INDIRECT WASTE JS - JANITOR SINK K - KITCHEN WASTE KEC - KITCHEN EQUIPMENT CONTRACTOR K - KITCHEN WASTE KEC - KITCHEN EQUIPMENT CONTRACTOR L - LENGTH LA - LABORATORY COMPRESSED AIR LAV - LAVATORY LBS - POUNDS LCW - LABORATORY COLD WATER LEC - LABORATORY EQUIPMENT CONTRACTOR LHW - LABORATORY HOT WATER LHWR - LABORATORY HOT WATER RETURN LPC - LOW PRESSURE CONDENSATE RETURN LPS - LOW PRESSURE STEAM SUPPLY LV - LABORATORY VACUUM OR LABORATORY VENT LW - LABORATORY WASTE MA - MEDICAL COMPRESSED AIR MAP - MASTER ALARM PANEL (MEDICAL GAS) MAX - MAXIMUM MB - MOP BASIN MC - MECHANICAL CONTRACTOR (DIVISION 23) MEZZ - MEZZANINE MFR - MANUFACTURER MH - MANHOLE MIN - MINIMUM OR MINUTE MISC - MISCELLANEOUS MTD - MOUNTED MTG - MOUNTING MPC - MEDIUM PRESSURE CONDENSATE RETURN MPS - MEDIUM PRESSURE STEAM SUPPLY MU - WATER MAKE-UP MV - MEDICAL SURGICAL VACUUM N2 - MEDICAL NITROGEN NG - GASOLINE (NON-LEAD) NIC - NOT IN CONTRACT NO - MEDICAL NITROUS OXIDE NOM - NOMINAL NPW - NON-POTABLE WATER NPT - NATIONAL PIPE THREAD NTS - NOT TO SCALE 02 - MEDICAL OXYGEN OA - OUTDOOR AIR OD - OUTSIDE DIAMETER OR OVERFLOW DRAIN OFCI - OWNER FURNISHED CONTRACTOR INSTALLED OFOI - OWNER FURNISHED OWNER INSTALLED P - PROPANE GAS PC - PLUMBING CONTRACTOR (DIVISION 22) OR PUMPED CONDENSATE RETURN PD - PUMP DISCHARGE OR PARAPET DRAIN PIV - POST INDICATOR VALVE PLBG - PLUMBING PS - PRE-ACTION/DELUGE SPRINKLER PRESS - PRESSURE PRV - PRESSURE REGULATING VALVE PSF - POUNDS PER SQUARE FOOT PSI - POUNDS PER SQUARE INCH PSV - PRESSURE SUSTAINING VALVE PSIG - POUNDS PER SQUARE INCH GAUGE PW - PURE WATER RA - RETURN AIR RAD - RADIUS RCP - REINFORCED CONCRETE PIPE RD - ROOF DRAIN REC - RECESSED REQD - REQUIRED RI - ROUGH IN RL - REFRIGERANT LIQUID ROS - REVERSE OSMOSIS WATER SUPPLY ROR - REVERSE OSMOSIS WATER RETURN RPM - REVOLUTIONS PER MINUTE RS - REFRIGERANT SUCTION RV - RELIEF VALVE S - SPRINKLER (WET) SA - SHOCK ARRESTOR OR SUPPLY AIR SAN - SANITARY OR SANITARY DRAIN SCH - SCHEDULE SCW - SOFT COLD WATER SD - SPRINKLER DRAIN OR SUBSOIL DRAIN SH - SHOWER SHT - SHEET SK - SINK SPEC - SPECIFICATIONS SQ - SQUARE SR - SUPPLY RISER SS - SANITARY STACK (SOIL OR WASTE) OR STAINLESS STEEL STD - STANDARD STM - STORM OR STORM DRAINAGE STRUC - STRUCTURAL OR STRUCTURE SUC - SITE UTILITY CONTRACTOR T - FUEL TANK VENT TD - TRENCH DRAIN TEMP - TEMPERATURE TOB - TOP OF BEAM TOD - TOP OF DUCT TOE - TOP OF EQUIPMENT TOF - TOP OF FOOTING TOJ - TOP OF JOIST TOP - TOP OF PIPE TOS - TOP OF SLAB OR TOP OF STEEL TF - TRAP FILLER TP - TRAP PRIMER OR TRAP PRIMER DISCHARGE TW - TEMPERED WATER TYP - TYPICAL UR - URINAL UNO - UNLESS NOTED OTHERWISE V - VENT OR SANITARY SEWER VENT VAC - VACUUM VC - VACUUM CLEANING VCV - VACUUM CLEANING VALVE VE - VACUUM EXHAUST VEL - VELOCITY VIB - VALVE IN BOX VOL - VOLUME VP - VACUUM PUMP VS - VENT STACK VTR - VENT THROUGH ROOF VR - VENT RISER W/ - WITH W/0 - WITHOUT W - WASTE WAGD - WASTE ANESTHESIA GAS DISPOSAL WC - WATER CLOSET WCO - WALL CLEANOUT WH - WALL HYDRANT OR WATER HEATER WIV - WALL INDICATOR VALVE WS - WATER SERVICE YCO - YARD CLEANOUT ZVC - ZONE VALVE CABINET PIPE RISER NOTE: ALL SYMBOLS AND ABBREVIATIONS ARE SUBJECT TO MODIFICATIONS ON OTHER DRAWINGS. ALL SYMBOLS OR ABBREVIATIONS MIGHT NOT NECESSARILY BE USED ON THIS PROJECT. www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 12:36:12 PMP001 SYMBOLS, ABBREVIATIONS & INDEX Sun King Spirits RGF RGF 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 PLUMBING SHEET LIST Sheet Number Sheet Name P001 SYMBOLS, ABBREVIATIONS & INDEX P101 FOUNDATION PLUMBING PLAN P102 FIRST & SECOND FLOOR PLUMBING PLAN P103 PLUMBING ROOF PLAN P400 SOIL, WASTE & VENT DIAGRAM P500 PLUMBING SCHEDULES AND DETAILS GAS LOAD DATA HVAC EQUIPMENT - 950 CFH BOILER - 630 CFH KITCHEN - 1500 CFH FIRE PLACE - 80 CFH WATER HEATER - 76 CFH TOTAL = 3236 CFH @ 2 PSI No. Description Date 1.2 4 4" - K6" - K 4" - SAN SAN4" - SAN 6" - K VR 4" - DCW6" - FS 4" - SAN 4"SS 3"SS SANSAN 8" - STM 8" - STM8" - STM 8" - STM6" SAN INV. ELEV. = 824.64' G FS 4" SAN INV. ELEV. = 825.10' CO+TEST-Y 4" SAN INV. ELEV. = 824.09' CO 8" STORM INV. ELEV. = 824.71' CO CO CO CO CO CO COCOCO G FFE = 828.10 CO FS ROUTE 6" FS TO FDC FD6 FD6 FD6 FD6 FD6 FD6 FD4 FD4 FD4 FD1 FD1 FD4 FD4FD4 FD5 FD2 FD2FD1 FD2 TD1 8" DS (7440 SF) 6" DS (2440 SF) D1 FD2 FD2 CO 4" STORM INV. ELEV. = 825.10' FD7 FD7 STM 4" 4" FD3 B2B2 2" SS 3" KW 2" SS VR VR VR VR A1 A2 A2 A1 C1 C1 C2 B3(2) VR B2 2.5" G 4" DCW 6" FS UP CO+TEST-Y CO+TEST-Y SAN SAN SANSANSAN SAN SANSAN STM 1 1 1 1 1 1 10" PVC CONDUIT 10" PVC CONDUIT www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 12:36:16 PMP101 FOUNDATION PLUMBING PLAN Sun King Spirits RGF RGF 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 SCALE: 1/8" = 1'-0" 0 - Plumbing1 PLAN NOTES 1. REFER TO CIVIL DRAWINGS FOR CONTINUATION. No. Description Date CRCRCRCRCRCRBFPM A B C C.4 D E.7 11.2 1.4 2 2.4 3 4 5 6 Mill Room 121 Water 110 Food 1 120 JNTR CLST 119 Distillery 104 Freezer 109 Cooler 108 Cooler 107 Food 3 114 RR 116 RR 117 Hall 106 STAIR 112 STORAGE 105 Bar 102 Retail 122 Bar 103 Elec. 111 Food 2 115 Dining 101 Kitchen 113 VESTIBULE 100 Info 54 TD-1 FD4FD4 FD6FD6FD6FD6FD6FD6 FD4 FD4 FD4 FD4 FD1 HB-1 GAS METER K K VR P102 3 G G GGG GG FD5 FD1 FD1G GGFD2 B2 C2 C1 C1 A1 A2 A2 A1 B2 D1 (1220 SF) 8" DS DN (7440 SF) CO CO 6" DS DN (2440 SF) STM 6" 3" 3" 0.75" 3"1" 0.75" 0.75" 1" 0.5" 0.75" 0.75" 1" 1" 0.5" 2" 2" 1.25" 0.75" 3" 1" 3" 2" 2.5" 0.75" 2"1"0.5" 1.25"1" 3" 3" B4 HB-1 SAN SAN SANSANSANSAN CO CO PW PWB2PW0.5" 0.5" CO RD1OD1 (3720 SF) CORD1OD1(3720 SF) STM 6" 6" OD1 RD1 (1220 SF)RD1 OD1 4"4" 6"STMSTMSTM SAN SANFD2 FD2 PW 0.5" 1.5" 1.5" 1.5" 1.5" 2.5" 2.5" 0.75" 2.5" 1.5" 2" 1.5" F1 B3 B3 GREASE INTERCEPTOR 500 GALLON FD7 FD7 12 FD2 B2 FD4 4 3 41 4 4 5 30 FD5 B2 FD2 D1 A1 FD2 B1 B3 FD1 A2 A1 FD1A1 C1 C2 VR VR VR VR 3" 4" SS FD4 3" SS 8 17 12 26 25 27 28 31 34 27 VR 33 33 35 12 2727 34 12 12 30 31 35 36 29 35 2712 22 22 12 29 CA CA 23 CA 0.75" 24 32 17 12 12 25 0.75" 0.75" 0.75" G 100 CFH 125 CFH G 0.75" 17 17 10" PVC CONDUIT 10" PVC CONDUIT A B C C.4 D E.7 11.2 1.4 2 2.4 3 4 5 6 RR 212 PIZZA OVEN 216 HALL 206 BOILER ROOM 207 RR 204 RR 205 STAFF BREAK 211 CATERING PREP 214 SUPPORT 215 JAN 208 OFFICE 210 BAR 201 DECK 202 PRIVATE FUNCTION 203 DINING 200 STAIR 213 Hall 209 NG NG NGPW 4"VTRFD1 FD1 FD2 FD4 FD5 FD4 C2 C2 C1 A1 A1 A2 A1 B1 D1 A2 B2 FD2 FD2 VVVVVVV V1.25"GGGG 0.75" 0.75" 1" F1 B3 B4 1 2 4" AIR INTAKE 4" EXHAUST 1"G DN 22 10 10 12 12 11 12 18 11 21 13 11 15 14 16 19 11 1219 20 HB-1 9 B2 B2 10" PVC CONDUIT STUB A 6 SALT STORAGE DWH1 ROP1,2 ROST1 ROM1 CF1 WS1 TMV1 RCP1 ET1 FD2 FD2 FD3 HB-1 4" AIR INTAKE 4" EXHAUST NC TMV2 G GPWPWPW PW 1" 1" 1.25" 1.25" 0.75" 1" 1.25" 3" 0.75" 1" 1" 5 P500 7 38 3839 40 1" 37 www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 12:36:23 PMP102 FIRST & SECOND FLOOR PLUMBING PLAN Sun King Spirits RGF RGF 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 SCALE: 1/8" = 1'-0" 1 - Plumbing1 SCALE: 1/8" = 1'-0" 2 - Plumbing2 SCALE: 1/2" = 1'-0" ENLARGED WATER ROOM3 PLAN NOTES 1. PRESSURE REGULATING VALVE SET @ 14" W.C. FROM 2 PSI (200CFH). 2. PRESSURE REGULATING VALVE SET @ 14" W.C. FROM 2 PSI (350CFH). 3. PRESSURE REGULATING VALVE SET @ 14" W.C. FROM 2 PSI (40 CFH). 4. PRESSURE REGULATING VALVE SET @ 14" W.C. FROM 2 PSI (500CFH). 5. PRESSURE REGULATING VALVE SET @ 14" W.C. FROM 2 PSI (400CFH). 6. PRESSURE REGULATING VALVE SET @ 14" W.C. FROM 2 PSI (630CFH). 7. PRESSURE REGULATING VALVE SET @ 14" W.C. FROM 2 PSI (76 CFH). 8. 4" DCW DROP TO REDUCED PRESSURE BACKFLOW PREVENTER. ROUTE DRAIN LINE TO NEAREST FLOOR DRAIN. 9. CONNECT 0.75" G TO FIRE PLACE PER MANUFACTURER'S INSTRUCTIONS. 10. 2" CW DN. PROVIDE FULL SIZE MANIFOLD WITH VALVE AND SERVE EACH FIXTURE INDIVIDUALLY FROM MANIFOLD. INSTALL HAMMER ARRESTOR. 11. 0.75" DCW, DHW DN. 12. INSTALL TRAP PRIMER ON FLOOR DRAIN. 13. 0.75" G, PW DN. CONNECT 0.75" G, PW TO BOILER PER MANUFACTURERS INSTRUCTIONS. 14. 1.25" DCW DN. 15. 0.5" DHW DN. 16. 0.75" G, PW DN. CONNECT PW TO ICE MACHINE. STUB & CAP IN #216 FOR FUTURE. 17. STUB 10" PVC CONDUIT UP 12"AFF. 18. CONNECT 1.25" G TO AHU PER MANUFACTURERS INSTRUCTIONS. 19. 0.5" DCW, DHW DN. 20. 0.5" PW DN. 21. 1.25" G DN. LOCATE SHUT OFF VALVE BELOW LAY-IN CEILING. 22. 2" CW DROP. PROVIDE FULL SIZE MANIFOLD WITH VALVE AND SERVE EACH FIXTURE INDIVIDUALLY FROM MANIFOLD. INSTALL HAMMER ARRESTOR. 23. 0.75" CA DROP TO OWNER PROVIDED CONTRACTOR INSTALLED AIR COMPRESSOR. 24. COORDINATE FINAL 0.75" CA TERMINATION POINT WITH OWNER. 25. 0.75" G UP. 26. 1" G UP. 27. 0.75" DCW, DHW UP. 28. 1.25" G UP. 29. 0.5" DCW, DHW UP. 30. 0.75" G, PW UP. 31. 0.5" PW DROP. 32. 0.75" DCW UP. 33. 2" DCW UP. 34. 0.75" DCW, DHW UP. 35. 1.5" G DROP, STUB PIPING IN WALL FOR FUTURE. 36. 0.5" DCW, DHW DROP. 37. 1" G DROP TO DWH1. 38. 1" DCW DROP TO WS1. 39. 1" DCW, DHW DROP - 1" 77F DHW UP FROM TMV-2. 40. 1" SCW DROP TO REDUCED PRESSURE BACKFLOW PREVENTER. ROUTE DRAIN LINE TO NEAREST FLOOR DRAIN. 41. PRESSURE REGULATING VALVE SET @ 14" W.C. FROM 2 PSI (265 CFH). GENERAL NOTES 1. COORDINATE ALL NATURAL GAS VALVE LOCATIONS WITH RETURN AIR PLENUMS. NO VALVES ARE PERMITTED TO BE LOCATED IN PLENUM SPACES. 2. PROVIDE LONG SWEEP 90 DEGREE ELBOWS ON PVC CONDUIT. COORDINATE EXACT LOCATIONS AND REQUIREMENTS WITH OWNER PRIOR TO INSTALLATION. 3. PVC PIPING LOCATED WITH IN RETURN AIR PLENUM SPACE IS REQUIRED TO BE FIRE WRAPPED. WRAPPING SHALL BE 3M FIRE BARRIER PLENUM WRAP 5A+ OR EQUAL. 4. ROUTE ALL NATURAL GAS REGULATOR VENTS TO THE OUTSIDE INDIVIDUALLY PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS. 5. ALL DRAINAGE PIPING LOCATED ABOVE FOOD PREP AND DINING AREAS SHALL HAVE A GALVANIZED DRAIN PAN INSTALLED UNDER DRAINAGE PIPING. No. Description Date ROOF SYSTEM 01 ROOF SYSTEM 01 ROOF SYSTEM 02 TYP. OPEN TO BELOW A B C C.4 D E.7 11.2 1.4 2 2.4 3 4 5 6 4"VTR OD1 RD1OD1 RD1 (3720 SF)(3720 SF) (1220 SF)(1220 SF)RD1 OD1 RD1 OD1 www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 12:36:25 PMP103 PLUMBING ROOF PLAN Sun King Spirits RGF RGF 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 SCALE: 1/8" = 1'-0" Roof1 No. Description Date 2"2" 1.5" 2" 2.5" 2" 2"1.5" 3" 3"4" 4" 3" 4" 2" 2" 3" 3" 3" 3" FD6 FD6 FD6 FD6 FD6 FD6 FD4 FD4 3" 3" 4" 4" 3"3" 3" 3" 2" 4" 4" 6" 6" 3"3" 3" CO CO CO CO CO CO 3" 3" 3" 3" 3" 3" 4" 4" FD1 C1 C2 C2 A1 A1 A2 FD1 A2 3" 2" 6" 4" 2" 2" 2" 2" 2" 1.5" 1.5"2" 2" 2" 2" 2" 4" 4" 3"4" 3" A2 A2 A1 B2 A1 FD4 FD4 FD2 FD4 FD1 4" 4" FD2 1.5" 1.5" 1.5" 2" 2.5" 6" 4" 3" 3"3" 4" 3" 3" 4" 4" 2.5" 2.5" 2" 2" 4" 4" 4" 4" 2"1.5" 2.5" 2" 2" 2" 2" 2" 2" 2" 2"2"2" 2" 1.5" 2.5" 2.5" 2" TD-1 FD4 FD4 D1 FD4FD2 A1 D1 C1 C1 FD5 FD5 FD1 FD2 FD2 B1 C2 B2 FD2 FD2 FD3 B3 B3 FD2 2" 2" 4"VTR2" B3 B4 2" FD1 CO CO GREASE INTERCEPTOR 500 GALLONS 2" 2" 2" 2" 4" 3" 3" 2" 2" 2" 2" 2" 2" 4"3" 4" 4" 3" 3" 4" 4" CO CO CO CO CO 6" 3" CO COORDINATE INSTALLATION WITH STRUCTURAL DWGS/DETAILS www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 12:36:32 PMP400 SOIL, WASTE & VENT DIAGRAM Sun King Spirits RGF RGF 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 SCALE: Soil, Waste & Vent Diagram1 DINING 101 RR 116 RR 117 DISTILLERY 104 BAR 102 RR 204 RR 205 WATER 110 BOILER ROOM 207 ROOM 105 DINING 101 JNTR 119 SUPPORT 215 FOOD 3 114 FOOD 3 115 RR 204 RR 205 No. Description Date 1 2 4 2 3 1 1 2 1 2 90 ELL PLUG 45 ELL45 ELL UNDISTURBED EARTH SURFACE CONCRETE PAD - SEE SCHEDULE PLUG TWO - 1.5" THICK OAK BLOCKS PIPE SIZE 90 ELL 45 ELL TEE & PLUG 3" 4" 6" 8" 10" 1.5" 2" 3" 4" 8" 1" 1"1.5"2"5" 1"1.5"2"8"7" (APPROX. ONE CU.FT. CONCRETE/SQ.FT. BEARING AREA) EARTH BEARING AREA - SQ. FT. 1 2 3 4 BUILDING WALL SHEETMETAL DOWNSPOUT CAST IRON DOWNSPOUT BOOT GRADE CONNECT TO DS BOOT PVC ELBOW, SEE PLAN FOR SIZE PVC PIPING, SEE PLANS FOR SIZE STORM SEWER PROVIDE ADAPTOR AND MAKE FINAL CONNECTION TO SEWER PIPE. 5'-0'' TRAP PRIMER, WITH DISTRIBUTION UNIT WHEN SERVING MULTIPLE DRAINS. LOCATE ABOVE CEILING IN FINISHED AREAS. 0.5''SUPPLY SHALL BE OFF TOP OF MAIN COLD WATER MAIN TPTPWALL FINISHED CEILING WHERE APPLICABLE FLOOR DRAINS FLOOR TP PIPING TO FLOOR DRAINS SHALL BE RUN BELOW FLOOR, UNLESS NOTED OTHERWISE. INSTALL PIPING CONCEALED IN WALL IN FINISHED AREAS. INSTALL PIPING TIGHT TO WALL SURFACE IN UNFINISHED AREAS. 1 AIR GAP OVER FLOOR DRAIN. 2 COMBINATION TEMPERATURE-PRESSURE RELIEF VALVE. 3 MINIMUM 27" HEAT TRAP. 4 AIR GAP OVER FLOOR. 3 14 2 ET1 DWH1 140TMV1 RCP1 .PTP/T NOTES 1.25" 1.25" 1.25" 1.25"1.25" 0.75" 0.75" PIPE SIZE AS INDICATED ON PLANS SHUT-OFF VALVE EQUIPMENT CONNECTION PIPE SIZE EQUIPMENT CONNECTIONUNION PIPE CAP3'' MIN.USER NOTES: 1 USE AS A TYPICAL DETAIL FOR ALL GAS FIRED EQUIPMENT (WATER HEATERS, UNIT HEATER, ROOFTOP UNITS, ECT.) ON PROJECT. www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 12:36:39 PMP500 PLUMBING SCHEDULES AND DETAILS Sun King Spirits Checker Author 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 NOTES: 1. BASIS OF DESIGN: AO SMITH BTX-80 2. BASIS OF DESIGN: PUROMAX LP-5000 3. BASIS OF DESIGN: GRUNDFOS MQ3-45 4. BASIS OF DESIGN: AQUA SYSTEMS WS1.0 CC 300 5. BASIS OF DESIGN: B&G NBF-10S/LW 6. BASIS OF DESIGN: WATTS DETA-12 7. BASIS OF DESIGN: LAWLER 801 8. BASIS OF DESIGN: DEN HARTOG CB0300-42, WITH CB042-45ST STAND 9. BASIS OF DESIGN: AQUA SYSTEMS SCIITW250VT GENERAL NOTES: A. PROVIDE ROUGH-IN. B. INSTALL ALL "LOOSE" COMPONENTS. C. CONNECTION SIZES SHALL BE AS LISTED. TERMINAL OUTLETS AND INLETS ON EQUIPMENT MAY BE SMALLER AND INCREASER/REDUCER FITTINGS REQUIRED. PLUMBING EQUIPMENT MARK DESCRIPTION CAPACITYPRESSURE VOLUME EFFICIENCYINPUT ELECTRICAL (VOLTAGE - PHASE) CONNECTIO NS APPROX. DIMENSIONS SEISMIC RESTRAINTS SEE NOTEHEAD DROP TOTAL ACCEPTANCECFH KW BTU HP FLUID F U EL WIDTH / DIA. LENGTH HEIGHT REQUIRED IMPORTANCE FACTOR IN OUT CF1 CARBON FILTER 10 GPM/SF 5 PSI 120V-1PH 0.75 " 0.75 " 14" 65" 4 DWH1 DOMESTIC WATER HEATER 92 GPH @ 90 DEGREES F RISE 80 76 120V-1PH 1.5" 1.5" 27" 68-5 /8" 1 ET1 THERMAL EXPANSION TANK 5 GALLONS 3.1 GAL 1.25 " 6 RCP1 DOMESTIC HOT WATER RECIRC PUMP 1 GPM 15 FT .55 120V-1PH 0.75 " 0.75 " 5" 6" 5" 5 ROM1 REVERSE OSMOSIS MACHINE 5000 GPD @ 77 DEGREE F 115 PSI 0.5 120V-1PH 0.75 " 0.75 " 22" 23" 65" 2 ROP1, 2 REVERSE OSMOSIS DISTRIBUTION PUMPS 5 GPM 125 FT 1.150 120V-1PH 0.75 " 0.5" 8.5" 22" 12.5 " 3 ROST1 REVERSE OSMOSIS WATER STORAGE TANK 300 GALLON, CONICAL BOTTOM 8 TMV1 THERMOSTATIC MIXING VALVE 17 GPM 5 PSI 1.25 " 1.25 " 7 TMV2 THERMOSTATIC MIXING VALVE 5 GPM 5 PSI 1" 1"7 WS1 DUPLEX WATER SOFTENER 60,000 GRAINS; 19 GPM CONT, 26 GPM PEAK 15 PSI 120V-1PH 0.75 " 0.75 " 13" 54" 9 NOTES: 1. PROVIDE "TRUEBRO" HANDI-LAV GUARD MODEL 103E-Z OR APPROVED EQUAL 2. INSTALL TRIP LEVER ON WIDE SIDE OF STALL 3. PROVIDE HOSE, HOSE BRACKET, VINYL BUMPER GUARD, STAINLESS STEEL WALL GUARD, MOP HANGER, ACCESSORIES BY MOP SINK MANUFACTURER ADA HANDICAP ACCESSIBLE FS FLOOR SET FT FLUSH TANK FV FLUSH VALVE GN GOOSENECK HS HAND SHOWER QD QUICK DISCONNECT SB SINGLE BOWL SST STAINLESS STEEL VB VACUUM BREAKER VR VANDAL RESISTANT WB WRIST BLADE WH WALL HUNG SCHEDULE ABBREVIATIONS:GENERAL NOTE: 1. SUPPLY PIPE SIZES IN THIS SCHEDULE ARE FIXTURE OR SUPPLY STOP CONNECTION SIZES. DOMESTIC COLD AND HOT WATER SUPPLY PIPE SIZES SERVING FIXTURES SHALL BE, AT A MINIMUM, THE SIZES LISTED UNLESS NOTED OTHERWISE OR LABELED ON THE FLOOR PLANS. DOMESTIC COLD WATER SUPPLY PIPE SIZES SERVING FLUSH VALVES SHALL BE AT MINIMUM ONE PIPE SIZE LARGER THAN THE INDICATED CONNECTION SIZE, OR SIZED AS SHOWN ON THE FLOOR PLANS. PIPING AT THE FLUSH VALVE CONNECTION OF A SIZE EQUAL TO THE CONNECTION SIZE SHALL BE LIMITED TO A MAXIMUM 2 FEET IN DEVELOPED LENGTH AND INCLUDE A MAXIMUM OF ONE 90 DEGREE ELBOW FITTING. FULL SIZE MANIFOLDS, WHERE INDICATED ON THE FLOOR PLANS, SHALL BE PROVIDED FULL SIZE FOR THE LENGTH OF THE PIPING CHASE AND TERMINATED WITH A FULL SIZE CAP. A. ZURN (KOHLER, CRANE, AMERICAN STANDARD) B. SLOAN (DELANY, ZURN) _ C. OLSONITE (BENEKE, CHURCH, BEMIS) _ D. SMITH (WADE, ZURN, JOSAM, WATTS) _ E. CHICAGO (TOTO, T&S BRASS, ZURN) _ F. GUY GRAY (OATEY, PLASTIC ODDITIES) _ G. McGUIRE (EBC, DEARBORN BRASS) _ H. FIAT (STERN WILLIAMS, CREATIVE IND.) _ J. ELKAY (JUST WITH LUG AND SCREW) _ K. AMERICAN STANDARD (ZURN, ELKAY, KOHLER) _ L. LEONARD (POWERS, SYMMONS) _ M. AQUARIUS (AQUA-BATH, KOHLER, CRANE) _ N. BRADLEY (SLOAN, ZURN, AMERICAN STANDARD) _ _ _ _ CATALOG NUMBERS INDICATED ARE THOSE OF THE FIRST NAMED MANUFACTURER IN EACH CATEGORY LISTED BELOW - ADDITIONAL MANUFACTURERS ARE LISTED IN PARENTHESIS PLUMBING FIXTURES MARK DESCRIPTION MOUNTING HEIGHT FLOW CONTROL SUPPLY WASTE & VENT FIXTURE SUPPLY TRIM SUPPLY / STOP WASTE TRIM TRAP / FIX. DR. MISC. SEE NOTE GPM GPF MANUAL METERINGSENSOR COLD WATER HOT WATER TEMPERED NAT. GAS FIX. OUTLET TRAP FIX. DRAIN WASTE-MIN. VENT-MIN. INDIRECT AIR GAP AIR BREAK MFR.CAT. NO. MFR.CAT. NO. MFR.CAT. NO. MFR.CAT. NO. MFR.CAT. NO. MFR.CAT. NO. ELECTRIC BATTERYA1 WATER CLOSET/FS/FV/ADA 17" 1.6 ●1" 3" 3" 3" 2" A Z5655-BWL1 B 111-1.6 C 95SS 2 A2 WATER CLOSET/FS/FV 15" 1.6 ●1" 3" 3" 3" 2" A Z5655-BWL1 B 111-1.6 C 95SS B1 LAVATORY/WH/ADA 34" .5 ●0.5" 0.5" 1.25 " 1.25 " 1.5" 1.5" 1.5" A Z5364 K 605B.105 G 2165LK G 155A G 8902 1 B2 LAVATORY/WH 31" .5 ●0.5" 0.5" 1.25 " 1.25 " 1.5" 1.5" 1.5" A Z5364 K 605B.105 G 2165LK G 155A G 8902 B3 LAVATORY/WH/ADA/ 34" .5 ●1.25 " 1.5" 1.5" 1.5" N LVQD3-TMA-L SD-HD1 G 2165LK G 155A G 8902 B4 LAVATORY/WH/ADA 34 .5 ●1.25 " 1.5" 1.5" 1.5" N LVQD2-TMA-L SD-HD1 G 2165LK G 155A G 8902 C1 URINAL/FV 24" 1 ●1" 2" 2" 2" 1.5" A Z5755-U B 186-1 C2 URINAL/ADA/FV 17" 1 ●1" 2" 2" 2" 1.5" A Z5755-U B 186-1 D1 MOP BASIN/FS FLOOR 12 ●0.75 " 0.75 " 3" 3" 3" 3" 2" H MSB-2424 E 897-CP 3 F1 SCULLERY SINK/SS FLOOR 2.2 ●2" 2"●BY OWNER BY OWNER G 2165LK HB-1 WALL HYDRANT 24" AFG 0.75 " REFER TO SPEC NOTES: 1. SECURED 1/2 GRATE GENERAL NOTE: 1. ALL DRAINS ARE MANUFACTURED BY J.R. SMITH UNLESS NOTED OTHERWISE. DRAINS MARK CATALOG NOS. TYPE BODY OUTLET STRAINER / GRATE TOP FINISH ADDITIONAL FEATURES SEE NOTE FLOOR ROOF AREAWAY CAST IRON BRASS ACID RESIST. STAINLESS STEEL PLASTIC SIZE BOTTOM SIDESIZE ADJUSTABLE FLAT DOME RECESSED FUNNEL HINGED STAINLESS STEEL NICKLE-BRONZE CAST IRON ACID RESIST. STAINLESS STEEL PLASTIC DUCTILE IRON ANCHOR FLANGE FLASHING CLAMP DBL DRAINAGE SED. BUCKET AUX. STRAINER BEARING PAN U'DECK CLAMP 2" STANDPIPE TRAP PRIMER CON. WATER DAM DIAMETER / WIDTH LENGTHFD1 2005Y-A ● ●3"●5" -12"● ● ●●● FD2 2310Y ● ●3"●5" -12"● ● ● ●● FD3 2633Y-12 ● ●3"●5" -12"● ●● ● ●1 FD4 3021Y ● ●3"●5" -12"● ● ● ● ● FD5 3101Y-12 ● ●4"●12" 12"● ● ● ● ●1 FD6 2450 ● ●3"●5" -12"● ● ●●●1 FD7 2473 ● ●3"●5" -12"● ● ● ● ● ● OD1 1074 ● ●4"●15"● ●● ● ● ● ● ● ● RD1 1015 ● ●4"●15"● ●● ● ● ● ● ● TD-1 9665 ● ●3"● ● ● ● ●● SCALE: NONE UNDER GROUND WATER PIPE THRUST BLOCKS1 SCALE: NONE DOWNSPOUT BOOT2 SCALE: NONE TRAP PRIMER4 SCALE: NONE DOMESTIC WATER HEATER PIPING5 SCALE: NONE TYPICAL GAS CONNECTION AT EQUIPMENT6SCALE: NONE GREASE INTERCEPTOR DETAIL7 No. Description Date