Loading...
HomeMy WebLinkAbout06_2017-03-30 - Sun King Distillery - CDs - DIV-23 DWGSNOTE: ALL SYMBOLS AND ABBREVIATIONS ARE SUBJECT TO MODIFICATIONS ON OTHER DRAWINGS. ALL SYMBOLS OR ABBREVIATIONS MIGHT NOT NECESSARILY BE USED ON THIS PROJECT. ABBREVIATIONS AC - AIR COMPRESSOR OR AIR CONDITIONER ACCU - AIR COOLED CONDENSING UNIT AD - ACCESS DOOR OR AREA DRAIN ADJ - ADJUSTABLE AFF - ABOVE FINISHED FLOOR AFG - ABOVE FINISHED GRADE AFMS - AIR FLOW MEASURING STATION ALT - ALTERNATE AP - ACCESS PANEL APPROX - APPROXIMATE ARCH - ARCHITECT OR ARCHITECTURAL ASSY - ASSEMBLY ATC - AUTOMATIC TEMPERATURE CONTROL BDD - BACK DRAFT DAMPER BFP - BACKFLOW PREVENTER BLDG - BUILDING BOB - BOTTOM OF BEAM BOD - BOTTOM OF DUCT BOE - BOTTOM OF EQUIPMENT BOF - BOTTOM OF FOOTING BOG - BOTTOM OF GRILLE BOP - BOTTOM OF PIPE BOT - BOTTOM BTU - BRITISH THERMAL UNIT BTUH - BRITISH THERMAL UNIT PER HOUR CBD - COUNTER BALANCED BACKDRAFT DAMPER CFCI - CONTRACTOR FURNISHED CONTRACTOR INSTALLED CFM - CUBIC FEET PER MINUTE CHS - CHILLED WATER SUPPLY CHR - CHILLED WATER RETURN CHGR - CHILLED WATER GLYCOL SOLUTION RETURN CHGS - CHILLED WATER GLYCOL SOLUTION SUPPLY CLG - CEILING CMU - CONCRETE MASONRY UNIT CO - CLEAN OUT CO2 - CARBON DIOXIDE CONN - CONNECT OR CONNECTION CONTR - CONTRACTOR CTR - CENTER CU - COPPER CW - COLD WATER CWR - CONDENSER WATER RETURN CWS - CONDENSER WATER SUPPLY D - DRAIN LINE DB - DRY BULB DDC - DIRECT DIGITAL CONTROLS DI - DEIONIZED WATER DIA - DIAMETER DIM - DIMENSION DN - DOWN DWG - DRAWING EA - EACH OR EXHAUST AIR EAT - ENTERING AIR TEMPERATURE EC - ELECTRICAL CONTRACTOR (DIVISION 26) EJ - EXPANSION JOINT ELEC - ELECTRICAL ELEV - ELEVATOR EQUIP - EQUIPMENT ET - EXPANSION TANK ETR - EXISTING TO REMAIN EQS - EQUIPMENT SUPPLIER EWT - ENTERING WATER TEMPERATURE EXH - EXHAUST EXP - EXPANSION EXT - EXTERIOR EX - EXISTING FD - FLOOR DRAIN FF - FINISHED FLOOR ELEVATION FLR - FLOOR FOB - FLAT ON BOTTOM FOF - FUEL OIL FLOW FOG - FUEL OIL GAUGE FOR - FUEL OIL RETURN FOS - FUEL OIL SUPPLY FOT - FLAT ON TOP FPM - FEET PER MINUTE FSC - FIRE SUPPRESSION CONTRACTOR (DIVISION 21) FT - FEET FTG - FOOTING G - GAS OR NATURAL GAS GA - GAUGE GAL - GALLON GALV - GALVANIZED GC - GENERAL TRADES CONTRACTOR GPM - GALLONS PER MINUTE HB - HOSE BIBB HC - HVAC CONTRACTOR (DIVISION 23) HD - HUB DRAIN HG - REFRIGERANT HOT GAS HP - HORSEPOWER HPC - HIGH PRESSURE CONDENSATE RETURN HPS - HIGH PRESSURE STEAM SUPPLY HR - HOUR HT - HEAT TRACE HTR - HEATER HVAC - HEATING, VENTILATING, AND AIR CONDITIONING HW - HOT WATER HWR - HEATING HOT WATER RETURN HWS - HEATING HOT WATER SUPPLY ID - INSIDE DIAMETER INV - INVERT ELEVATION IN - INCHES KEC - KITCHEN EQUIPMENT CONTRACTOR L - LENGTH LAT - LEAVING AIR TEMPERATURE LAV - LAVATORY LBS - POUNDS LPC - LOW PRESSURE CONDENSATE RETURN LPS - LOW PRESSURE STEAM SUPPLY LWT - LEAVING WATER TEMPERATURE MAX - MAXIMUM MDD - MOTORIZED DAMPER MEZZ - MEZZANINE MFR - MANUFACTURER MH - MANHOLE MIN - MINIMUM OR MINUTE MISC - MISCELLANEOUS MTD - MOUNTED MTG - MOUNTING MPC - MEDIUM PRESSURE CONDENSATE RETURN MPS - MEDIUM PRESSURE STEAM SUPPLY MU - WATER MAKE-UP NIC - NOT IN CONTRACT NOM - NOMINAL NPT - NATIONAL PIPE THREAD NTS - NOT TO SCALE OA - OUTDOOR AIR OBD - OPPOSED BLADE DAMPER OD - OUTSIDE DIAMETER OFCI - OWNER FURNISHED CONTRACTOR INSTALLED OFOI - OWNER FURNISHED OWNER INSTALLED P - PROPANE GAS PC - PLUMBING CONTRACTOR (DIVISION 22) OR PUMPED CONDENSATE RETURN PLBG - PLUMBING PRESS - PRESSURE PRV - PRESSURE REGULATING VALVE PSF - POUNDS PER SQUARE FOOT PSI - POUNDS PER SQUARE INCH PSIG - POUNDS PER SQUARE INCH GAUGE RA - RETURN AIR RAD - RADIUS RCP - REFLECTED CEILING PLAN RD - ROOF DRAIN REC - RECESSED REQD - REQUIRED RI - ROUGH IN RL - REFRIGERANT LIQUID ROS - REVERSE OSMOSIS WATER SUPPLY ROR - REVERSE OSMOSIS WATER RETURN RPM - REVOLUTIONS PER MINUTE RS - REFRIGERANT SUCTION S - SPRINKLER (WET) SA - SUPPLY AIR SAN - SANITARY OR SANITARY DRAIN SCH - SCHEDULE SCW - SOFT COLD WATER SHT - SHEET SPEC - SPECIFICATIONS SQ - SQUARE SR - SUPPLY RISER SRV - SAFETY RELIEF VALVE SS - STAINLESS STEEL STD - STANDARD STM - STORM OR STORM DRAINAGE STRUC - STRUCTURAL OR STRUCTURE SUC - SITE UTILITY CONTRACTOR TEMP - TEMPERATURE TOB - TOP OF BEAM TOD - TOP OF DUCT TOE - TOP OF EQUIPMENT TOF - TOP OF FOOTING TOJ - TOP OF JOIST TOP - TOP OF PIPE TOS - TOP OF SLAB OR TOP OF STEEL TYP - TYPICAL UNO - UNLESS NOTED OTHERWISE V - VENT VAC - VACUUM VEL - VELOCITY VIB - VALVE IN BOX VOL - VOLUME VTR - VENT THROUGH ROOF VR - VENT RISER W/ - WITH W/0 - WITHOUT WB - WET BULB WCO - WALL CLEANOUT GENERAL FLOOR PLAN NOTES PLAN NOTE. APPLIES ONLY TO THE SHEET WHICH IT IS SHOWN UNLESS NOTED OTHERWISE. DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL. 3 3 A1 EQUIPMENT, DEVICE, OR PLUMBING FIXTURE MARK. LETTER DESIGNATIONS REFER TO SCHEDULES. H1 H1OR EQUIPMENT REFERENCE. LETTER DESIGNATION VARIES. REFER TO SCHEDULES. 2 1 H2 B H2 RISER OR STACK NUMBER DETAIL: B = DETAIL DESIGNATION H2 = SHEET WHERE DETAIL IS LOCATED SECTION: 1 = SECTION DESIGNATION H2 = SHEET WHERE DETAIL IS LOCATED A1 "UP TO" SYMBOL (ITEM ON FLOOR ABOVE) APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO TOP OR BOTTOM OF EQUIPMENT, UNLESS NOTED OTHERWISE 10" ELEV: 8' - 0"ELEV: 8' - 0" TOD: 8' - 10" BOD: 7' - 2" 20x20 20x20 APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO TOP OR BOTTOM OF DUCTWORK, UNLESS NOTED OTHERWISE APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO CENTERLINE OF PIPE, UNLESS NOTED OTHERWISE DL-1 UC-X DOOR UNDERCUT. X = HEIGHT OF UNDERCUT IN INCHES; 0.75 INCH UNDERCUT IF NO HEIGHT IS NOTED. COORDINATE WITH GC. DOOR LOUVER. 1 = SQUARE FEET OF LOUVER. CONNECT TO EXISTING HVAC PIPING DESIGNATIONS CHILLED WATER SUPPLY PIPECHS CONDENSER WATER SUPPLY PIPECWS CONDENSER WATER RETURN PIPECWR DRAIN LINE. PITCH IN DIRECTION INDICATEDD HEATING HOT WATER SUPPLY PIPEHWS HEATING HOT WATER RETURN PIPEHWR WATER MAKE-UP PIPEMU VENT PIPEV REFRIGERANT LIQUID LINERL REFRIGERANT SUCTION LINERS EXPANSION TANK PIPEET REFRIGERANT HOT GAS LINEHG LOW PRESSURE CONDENSATE RETURN PIPELPC LOW PRESSURE STEAM SUPPLY PIPELPS MEDIUM PRESSURE CONDENSATE RETURN PIPEMPC MEDIUM PRESSURE STEAM SUPPLY PIPEMPS PUMPED CONDENSATE RETURN PIPEPC HIGH PRESSURE CONDENSATE RETURN PIPEHPC HIGH PRESSURE STEAM SUPPLY PIPEHPS STEAM SUPPLY PIPE - NUMBER INDICATES P.S.I.G.10 MISC SYMBOLS DUCTWORK SYMBOLS ROUND BRANCH DUCTWORKCONICAL FITTING ACOUSTIC FITTING ACOUSTIC FITTING ADAD D R R D RECTANGULAR BRANCH DUCTWORK SQUARE TEE WITH TURNING VANES NOTE: ALL SQUARE ELBOWS IN RECTANGULAR AND ROUND / OVAL DUCTWORK SHALL BE PROVIDED WITH TURNING VANES. EXISTING DUCTWORK TO REMOVED RETURN AIR, RELIEF AIR, OR TRANSFER AIR DUCTWORK. (UP AND DOWN) RADIUSED OR SQUARE WITH TURNING VANES. SUPPLY AIR OR OUTDOOR AIR DUCTWORK. (UP AND DOWN) RADIUSED OR SQUARE WITH TURNING VANES. EXHAUST AIR DUCTWORK. (UP AND DOWN) RADIUSED OR SQUARE WITH TURNING VANES. RECTANGULAR AND ROUND / OVAL DUCTWORK RISE / DROP WITH 90° RADIUSED OR SQUARE ELBOWS AND TURNING VANES. RADIUS ELBOW 90° SQUARE ELBOW (WITH TURNING VANES) NOTE: ALL SQUARE ELBOWS IN RECTANGULAR AND ROUND DUCTWORK SHALL BE PROVIDED WITH TURNING VANES. ACCESS DOOR OR PANEL DUCTWORK RISE IN DIRECTION OF AIR FLOW DUCTWORK DROP IN DIRECTION OF AIR FLOW DUCTWORK WITH ACOUSTICAL LINER. LISTED DUCT SIZES ARE INSIDE CLEAR DIMENSIONS. RECTANGULAR ROUND / OVAL FLEXIBLE DUCTWORK FLEXIBLE CONNECTION DUCTWORK CONSTRUCTED OF SPECIAL MATERIAL AS NOTED DIRECTION OF PITCH RECTANGULAR DUCTWORK DIMENSIONS (W x H)26x20 ROUND DUCTWORK DIMENSIONS (DIA)26ø OVAL DUCTWORK DIMENSIONS (W x H)26x20 OV DUCTWORK DEVICE SYMBOLS WALL OR DUCTWORK MOUNTED AIR DEVICE. SG1 = DESIGNATION (REFER TO AIR DEVICE SCHEDULE). 20x12 = DUCT CONNECTION SIZE (IN INCHES). 300 = REQUIRED CFM. 9'-0" = MOUNTING HEIGHT FROM FLOOR TO BOTTOM OF GRILLE. A3 10ø 300 MANUAL BALANCING VALVE DAMPER WITH LOCKING DEVICE BDD = BACK DRAFT DAMPER CBD = COUNTER-BALANCED BACK DRAFT DAMPER SD = SMOKE DAMPER FS = COMBINATION FIRE - SMOKE DAMPER MDD = MOTORIZED DAMPER AFMS = AIR FLOW MEASURING STATION DUCT MOUNTED SMOKE DETECTOR. COORDINATE LOCATION. HUMIDITY SENSOR - DUCT MOUNTED SG1 20x12 300 BOG: 9'-0" XXX A-D XX H SD SP AIR DEVICE. A3 = DESIGNATION (REFER TO FLOOR PLANS AND AIR DEVICE SCHEDULE FOR VARIOUS DESIGNATIONS). 10ø = NECK SIZE (IN INCHES). 300 = REQUIRED CFM. ALL AIR DEVICE DISCHARGE 4-WAY UNLESS NOTED WITH FLOW ARROWS. AIR DEVICE SHOWN IS 2-WAY SIDE THROW. METHOD OF IDENTIFICATION ALSO APPLIES TO OTHER CEILING MOUNTED AIR DEVICES. FIRE DAMPER A = TYPE (REFER TO FLOOR PLANS FOR VARIOUS TYPES) D OR S = DYNAMIC OR STATIC STATIC PRESSURE SENSOR - DUCT MOUNTED C CARBON DIOXIDE SENSOR - DUCT MOUNTED S TEMPERATURE SENSOR - DUCT MOUNTED CHECK VALVE T P FOB FOT SHUTOFF VALVE (REFER TO SPECIFICATIONS FOR REQUIRED TYPE BASED ON APPLICATIONS) CONCENTRIC PIPE REDUCER ECCENTRIC PIPE REDUCER PRESSURE GAUGE TEMPERATURE GAUGE OR THERMOMETER UNION CLEANOUT STRAINER STRAINER WITH A BLOW DOWN VALVE AND HOSE CONNECTION DRAIN VALVE WITH HOSE END CONNECTION AUTOMATIC FLOW CONTROLLER WITH P/T PLUG IN AND OUT EXPANSION JOINT MANUAL AIR VENT AUTOMATIC AIR VENT PRESSURE REDUCING VALVE 2 PORT AUTOMATIC CONTROL VALVE 3 PORT AUTOMATIC CONTROL VALVE QUICK OPENING MANUAL VALVE VACUUM BREAKER NEEDLE VALVE PRESSURE AND TEMPERATURE TEST PLUG VACUUM GAUGE WITH STOP END CAP GLOBE VALVE SHUTOFF VALVE AND BOX SHUTOFF VALVE ON RISER A M M N V COMBINATION SHUTOFF AND BALANCING VALVE (REFER TO SPECIFICATIONS FOR REQUIRED TYPE BASED ON APPLICATIONS) BALL VALVE BUTTERFLY VALVE GATE VALVE VALVES AND FITTINGS DOUBLE LINE SINGLE LINE SOLENOID VALVES SAFETY RELIEF VALVE. FOR HYDRONIC SYSTEMS PIPE DISCHARGE AIR GAPPED TO FLOOR DRAIN UNLESS NOTED OTHERWISE. FOR STEAM SYSTEMS PIPE DISCHARGE TO OUTDOORS. WATER METERM PRESSURE GAUGE WITH COCK AND SIPHON LOOP BI-METALIC STEAM TRAP AND DRIP ASSEMBLY THERMODYNAMIC STEAM TRAP AND DRIP ASSEMBLY INVERTED BUCKET STEAM TRAP AND DRIP ASSEMBLY FLOAT AND THERMOSTATIC STEAM TRAP AND DRIP ASSEMBLY THERMOSTATIC STEAM TRAP AND DRIP ASSEMBLY BM TD IB FT TS 10" TOE: 3' - 0" BOE: 0' - 6" CHILLED WATER GLYCOL SOLUTION RETURN PIPE (PROCESS)CHGR CHILLED WATER GLYCOL SOLUTION SUPPLY PIPE (PROCESS)CHGS CHILLED WATER RETURN PIPECHR SQUARE THROAT / RADIUS HEEL FITTINGS NOT ACCEPTABLE PIPING SYMBOLS DOUBLE LINE SINGLE LINE BOTTOM CONNECTION (45°) BRANCH TEE CONNECTION (NOTE: BULLHEAD TEE'S ARE NOT PERMITTED) DIRECTION OF PITCH DROP ELBOW DOWN ELBOW UP EXISTING PIPE TO BE REMOVED EXISTING PIPE TO REMAIN FLOW DIRECTION DESIGNATION PUMP RISE TOP CONNECTION (45°) TOP CONNECTION (90°) BOTTOM CONNECTION (90°) DD RR PIPE RISER RADIUS'D BRANCH RADIUS'D TEE EXISTING DUCTWORK TO REMAIN 15° MAX FOR DIVERGING, 30° MAX FOR CONVERGING TRANSITION EMERGENCY SHUTOFF STATION. 46" MOUNTING HEIGHT UNLESS NOTED OTHERWISE. SPACE TEMPERATURE SENSOR / THERMOSTAT. WHEN WALL MOUNTED, MOUNTING HEIGHT 46" TO MEET ADA REQUIREMENTS. WHEN MOUNTED NEXT TO WALL SWITCH COORDINATE WITH ARCHITECT. T DP DIFFERENTIAL PRESSURE SENSOR. WHEN WALL MOUNTED, MOUNTING HEIGHT 46" TO MEET ADA REQUIREMENTS. WHEN MOUNTED NEXT TO WALL SWITCH COORDINATE WITH ARCHITECT. H HUMIDITY SENSOR. WHEN WALL MOUNTED, MOUNTING HEIGHT 46" TO MEET ADA REQUIREMENTS. WHEN MOUNTED NEXT TO WALL SWITCH COORDINATE WITH ARCHITECT. CARBON DIOXIDE SENSOR. WHEN WALL MOUNTED, MOUNTING HEIGHT 46" TO MEET ADA REQUIREMENTS. WHEN MOUNTED NEXT TO WALL SWITCH COORDINATE WITH ARCHITECT.C CO CARBON MONOXIDE SENSOR. WHEN WALL MOUNTED, MOUNTING HEIGHT 46" TO MEET ADA REQUIREMENTS. WHEN MOUNTED NEXT TO WALL SWITCH COORDINATE WITH ARCHITECT. TEMPERATURE SENSOR. WHEN WALL MOUNTED, MOUNTING HEIGHT 46" TO MEET ADA REQUIREMENTS. WHEN MOUNTED NEXT TO WALL SWITCH COORDINATE WITH ARCHITECT. S S P TEMPERATURE SENSOR MOUNTED IN CEILING PLENUM. STATIC PRESSURE SENSOR.SP www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 11:15:04 AMM001 SYMBOLS, ABBREVIATIONS & INDEX Sun King Spirits EEL JSN 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 MECHANICAL SHEET LIST Sheet Number Sheet Name M001 SYMBOLS, ABBREVIATIONS & INDEX M101 FIRST FLOOR MECHANICAL PLAN M102 SECOND FLOOR MECHANICAL PLAN M103 ROOF MECHANICAL PLAN M501 MECHANICAL DETAILS M701 MECHANICAL SCHEDULES No. Description Date A B C C.4 D E.7 11.2 1.4 2 2.4 3 4 5 6 Mill Room 121 Water 110 Food 1 120 JNTR CLST 119 Distillery 104 Freezer 109 Cooler 108 Cooler 107 Food 3 114 Hall 118 RR 116 RR 117 Hall 106 STAIR 112 STORAGE 105 Bar 102 Retail 122 Bar 103 Elec. 111 Food 2 115 Dining 101 Kitchen 113 VESTIBULE 100 Info 54 14x14 12x12 225 CFM J2 12x12 225 CFM J2 12x6 75 CFM E1 10x10 8ø 50x20 8ø A1 250 CFM 24x24 175 CFM J348x20 6ø A1 50 CFM 6ø A1 100 CFM 6ø A1 100 CFM24ø20x12 14x12 12x5 255 CFM G2 12x6 310 CFM G2 12x6 310 CFM G212x6 310 CFM G2 12x6 310 CFM G2 12x6 310 CFM G2 12x5 255 CFM G2 12x5 255 CFM G2 12x5 255 CFM G2 12x5 255 CFM G2 12x5 255 CFM G2 12x5 255 CFM G2 10x4 125 CFM G2 10x4 125 CFM G2 12x6 200 CFM G2 14ø 18ø 12x6 310 CFM G2 12x6 310 CFM G2 12x5 255 CFM G2 12x5 255 CFM G2 20ø 16ø 14ø12x5 255 CFM G2 12x5 255 CFM G2 12x5 255 CFM G2 12x5 255 CFM G2 12x5 255 CFM G2 8ø A1 300 CFM 10ø A1 350 CFM 8ø A1 300 CFM 10ø 6ø 10x10 10ø 10x10 7x4 50 CFM H1 4 4 78 6 4 10x10 8ø T T EUH-1 EUH-2 2 3 1 5 5 6ø 48x20 R2 48x20 R2 9 9 EWH-1 11 10 10x10 T EUH-3 T RTU-2 12 RH-1 RH-2 12x12 12x12 J1 2 M102 T T T www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 11:15:09 AMM101 FIRST FLOOR MECHANICAL PLAN Sun King Spirits EEL JSN 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 SCALE: 1/8" = 1'-0" FIRST FLOOR MECHANICAL PLAN1 PLAN NOTES 1. FLARE TO 62" X 20". COVER END OF DUCT WITH 1/2" MESH HARDWARE CLOTH. 2. 67" X 27" SUPPLY UP TO RTU-2. TRANSITION AS REQUIRED FOR CONNECTION TO RTU-2. SEE SHEET M102 FOR CONTINUATION. 3. 76" X 20" RETURN UP TO RTU-2. TRANSITION AS REQUIRED FOR CONNECTION TO RTU-2. SEE SHEET M102 FOR CONTINUATION. 4. 10" X 10" GREASE DUCT. COORDINATE LOCATION WITH OWNER SPPLIED HOOD. TRANSITION AS REQUIRED FOR CONNECTION. 5. 48" X 20" INTERNALLY LINED TRANSFER DUCT. 6. 6" DIAMETER EXHAUST UP. SEE SHEET M102 FOR CONTINUATION. 7. 14" X 14" GREASE DUCT UP. SEE SHEET M102 FOR CONTINUATION. 8. 10" X 10" EXHAUST DUCT UP. SEE SHEET M102 FOR CONTINUATION. 9. 18" X 10" EXHAUST. TERMINATE AT 10' 0" A.F.F. COVER OPENING WITH STAINLESS STEEL 1/2" MESH HARDWARE CLOTH. SEE SHEE M102 FOR CONTINUATION. 10. 10" X 10" EXHAUST UP TO EF-6. SEE SEET M102 FOR CONTINUATION. 11. 30" X 6" EXHAUST GRILLE IN BOTTOM OF DUCT. COORDINATE LOCATION WITH BATTERY CHARGING STATION. 12. COORDINATE LOCATION OF THERMOSTAT WITH ARCHITECT AND ENGINEER. No. Description Date A B C C.4 D E.7 11.2 1.4 2 2.4 3 4 5 6 RR 212 PIZZA OVEN 216 HALL 206 BOILER ROOM 207 RR 204 RR 205 STAFF BREAK 211 214 CATERING PREP SUPPORT 215 JAN 208 OFFICE 210 63 CATERING ALCOVE BAR 201 DECK 202 PRIVATE FUNCTION 203 DINING 200 STAIR 213 Hall 209 RTU-1 RTU-2 AHU-1 12x6 300 CFM G2 12x6 300 CFM G2 12x6 300 CFM G2 12x6 320 CFM G2 12x6 320 CFM G2 12x6 320 CFM G2 12x6 320 CFM G2 12x6 320 CFM G2 12x6 320 CFM G2 12x12 75 CFM J2 12x8 75 CFM E1 24x12 225 CFM J2 24x12 225 CFM J2 12x12 J1 6ø A1 50 CFM 6ø A1 75 CFM 6ø A1 100 CFM 8ø A1 175 CFM 6ø A1 50 CFM 12x6 200 CFM H1 14x12 12x10 40x20 R2 12x6 320 CFM G2 T T T 10x12 18ø 16x8 670 CFM G1 16x8 665 CFM G1 16x8 665 CFM G1 10x10 12x6 300 CFM G2 24x12 R2 40x206ø 8ø 8ø 14x1214ø 20ø 12ø 16ø 12ø 14ø 6ø A1 25 CFM 12x6 320 CFM G2 12x6 320 CFM G212x6 320 CFM G2 16x6 400 CFM G2 16x6 400 CFM G2 PROCESS CHILLER ACCU-1 1 ZD-1 ZD-3 26ø16ø ZD-2 3 5 4 6 SP8 ZD-4 9 2 2 10 11 18x10 18x16 16ø 16ø T MD EF-6 ACCU ACCU ACCU 12 13 6ø A1 100 CFM 8ø A1 175 CFM ZD-2 ZD-3 14 ZD-1 18 17 ZD-4 16 7 22 2123 20 19 24 15 2 M102 24x12 36x36 MD MD T AHU-1 26ø RL www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 11:15:16 AMM102 SECOND FLOOR MECHANICAL PLAN Sun King Spirits EEL JSN 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 SCALE: 1/8" = 1'-0" SECOND FLOOR MECHANICAL PLAN1 PLAN NOTES 1. STAINLESS STEEL DRAINPAN UNDER RAH-1. PAN SHALL BE 6" LARGER THAN THROAT OF RAH-1 IN ALL DIRECTIONS. PAN SHALL HAVE 2" TALL SIDES AND BE WELDED WATERTIGHT. PAINT TO MATCH EXPOSED STRUCTURE. 2. 18" X 10" EXHAUST DUCT DOWN WALL. SEE SHEET M101 FOR CONTINUATION. 3. 6" DIAMETER EXHAUST UP AND DOWN. SEE SHEETS M103 AND M101 FOR CONTINUATION. 4. 14" X 14" GREASE DUCT UP AND DOWN. SEE SHEETS M103 AND M101 FOR CONTINUATION. 5. 14" X 12" EXHAUST UP, 10" X 10" EXHAUST DUCT DOWN. SEE SHEETS M101 AND M103 FOR CONTINUATION. 6. 8" DIAMETER EXHAUST UP. COORDINATE WITH PIZZA OVEN MANUFACTURER. SEE SHEET M103 FOR CONTINUATION. 7. REFRIGERANT PIPING SIZED BY EQUIPMENT MANUFACTURER. 8. SUPPLY DUCT STATIC PRESSURE SENSOR. 9. PROCESS CHILLER PROVIDED BY OWNER. FOR REFERENCE ONLY. 10. 18" X 16" EXHAUST DUCT UP. SEE SHEET M103 FOR CONTINUATION. 11. 72" X 36" LOUVER WITH FULL SIZE INSULATED CONTROL DAMPER. 12. CONDENSING UNIT FOR COOLER PROVIDED BY OWNER. FOR REFERENCE ONLY. 13. CONDENSING UNIT FOR FREEZER PROVIDED BY OWNER. FOR REFERENCE ONLY. 14. DUCT MOUNTED TEMPERATURE SENSOR. 15. 1" CONDENSATE DRAIN. TERMINATE OVER MOP BASIN. 16. 8" DIAMETER BOILER FLUE UP. SEE SHEET M103 FOR CONTINUATION. COORDINATE LOCATION WITH BOILER (BY OTHERS) LOCATION. 17. 6" FLUE FROM AHU-1. SEE SHEET M103 FOR CONTINUATION. 18. 6" COMBUSTION AIR TO AHU-1. SEE SHEET M103 FOR CONTINUATION. 19. 2" PROCESS CHGS AND CHGR DOWN WALL TO 8'-0" AFF. VALVE AND CAP. 20. 2 1/2" PROCESS STEAM DOWN WALL TO 8'-0" ADD. VALVE AND CAP. 21. 2 1/2" PROCESS STEAM. CONNECT TO BOILER (BY OTHERS). TRANSITION AT BOILER AS REQUIRED. 22. 2" PROCESS CHGS AND CHGR. CONNECT TO PROCESS CHILLER (BY OTHERS). TRANSITION AT CHILLER AS REQUIRED. 23. RACK PIPING VERTICALLY ON WALL. 24. PROVIDE TWO (2) COMBUSTION AIR OPENINGS BETWEEN BOILER ROOM 20D AND HALL 20B. LOCATE ONE (1) OPENING HIGH AND ONE (1) OPENING LOW AS REQUIRED BY NFPA31. EACH OPENING SHALL HAVE A MINIMUM FREE AREA OF 4.1 SQUARE FEET. SCALE: 1/8" = 1'-0" SECTION 12 No. Description Date A B C C.4 D E.7 11.2 1.4 2 2.4 3 4 5 6 EF-3 EF-2 EF-1 EF-4 EF-5 RAH-1 1 2 3 2 M102 www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 11:15:18 AMM103 ROOF MECHANICAL PLAN Sun King Spirits EEL JSN 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 SCALE: 1/8" = 1'-0" MECHANICAL ROOF PLAN1 PLAN NOTES 1. 6" FLUE FROM AHU-1. TERMINATE PER AHU MANUFACTURER. SEE SHEET M102 FOR CONTINUATION. 2. 6" COMBUSTION AIR INTAKE TO AHU-1. TERMINATE PER AHU MANUFACTURER. SEE SHEET M102 FOR CONTINUATION. 3. 8" DIAMETER BOILER FLUE. TERMINATE PER BOILER MANUFACTURER. No. Description Date SUPPLY DUCT 6 4 3 4 5 4 6 12 8 7 CEILING CEILING DIFFUSER 1. SQUARE-TO-ROUND ADAPTER IF DIFFUSER NECK IS SQUARE. CONNECT ADAPTOR TO DIFFUSER. SEAL TO AIR DEVICE, SEAL CLASS A. INSULATE ADAPTOR AND EXPOSED BACKSIDE SURFACES OF AIR DEVICE. 2. INSULATED FLEXIBLE DUCT SAME DIAMETER AS BRANCH DUCT , 3 FT. MAXIMUM TOTAL LENGTH PER AIR DEVICE. STRETCH FLEXIBLE DUCT TO AT LEAST 90% OF FULLY EXTENDED LENGTH. 3. SPIN-IN BRANCH TAP FITTING, STRAIGHT SIDE WITH MANUAL DAMPER. DAMPER SHAFT IN HORIZONTAL. INTEGRAL INSULATION GUARD SLEEVE REQUIRED FOR TAP FITTING TO MAIN DUCT WITH INTERNAL INSULATION, AND EXTENDED DAMPER SHAFT AND HANDLE WITH STAND-OFF TO ACCOMMODATE EXTERNAL INSULATION. 4. DUCT STRAP HANGER. ATTACH TO STRUCTURE. 5. STRAP HANGER REQUIRED IF LENGTH OF FLEXIBLE DUCT IS LONGER THAN 4 FT. 6. MINIMUM CENTERLINE RADIUS EQUAL TO DUCT DIAMETER. 7. ROUND SHEET METAL BRANCH DUCT, SAME SIZE AS DIFFUSER INLET UNLESS NOTED OTHERWISE. 8. CEILING T-BAR SUPPORT (FOR LAY-IN APPLICATIONS). COORDINATE AND VERIFY T-BAR TYPE FOR COMPATIBILITY WITH DIFFUSER. 9. RADIUS'D SHEET METAL ELBOW. 7 NOTES 9 ROUND SHEETMETAL BRANCH DUCT BRANCH CFM RD. DUCT SIZE 0 TO 80 CFM 6"D 81 TO 120 CFM 7"D 121 TO 200 CFM 8"D 401 TO 700 CFM 12"D 701 TO 1000 CFM 14"D 201 TO 400 CFM 10"D 7 CEILING RETURN OR EXHAUST GRILLE 553 56 8 98 4 1 2RETURN OR EXHAUST DUCT 1. SHEET METAL PLENUM, FULL SIZE OF GRILLE NECK, MINIMUM 6" TALL WITH SAME INTERNAL OR EXTERNAL INSULATION AS RETURN OR EXHAUST DUCT. CONNECT TO GRILLE. SEAL PLENUM AND CONNECTION TO GRILLE, SEAL CLASS A. 2. FLEXIBLE DUCT, SAME DIAMETER AS BRANCH DUCT , 1 FT. MAXIMUM TOTAL LENGTH PER AIR DEVICE. STRETCH FLEXIBLE DUCT TO AT LEAST 90% OF FULLY EXTENDED LENGTH. 3. SPIN-IN BRANCH TAP FITTING, STRAIGHT SIDE WITH MANUAL DAMPER. DAMPER SHAFT IN HORIZONTAL. INTEGRAL INSULATION GUARD SLEEVE REQUIRED FOR TAP FITTING TO MAIN DUCT WITH INTERNAL INSULATION. EXTENDED DAMPER SHAFT AND HANDLE WITH STAND-OFF REQUIRED FOR EXTERNALLY INSULATED DUCTWORK. 4. SPIN-IN TAP FITTING SIMILAR TO EXCEPT NO DAMPER. 5. DUCT STRAP HANGER. ATTACH TO STRUCTURE. 6. ROUND SHEET METAL BRANCH DUCT, SIZE AS INDICATED IN ADJACENT SCHEDULE UNLESS NOTED OTHERWISE ON PLANS. 7. CEILING T-BAR SUPPORT (FOR LAY-IN APPLICATIONS). COORDINATE AND VERIFY T-BAR TYPE FOR COMPATIBILITY WITH GRILLE. 8. MINIMUM CENTERLINE RADIUS EQUAL TO DUCT DIAMETER. 9. RADIUS'D SHEET METAL ELBOW. 7 3 NOTES 6" MAX7CEILING RETURN OR EXHAUST GRILLE 3 1 3 2 3 6 4 5 RETURN OR EXHAUST DUCT 1. 45 DEGREE STATIC BOOT AND MANUAL DAMPER. INTEGRAL INSULATION GUARD SLEEVE REQUIRED WHEN MAIN DUCT HAS INTERNAL INSULATION. EXTENDED DAMPER SHAFT AND HANDLE WITH STAND-OFF REQUIRED FOR EXTERNALLY INSULATED DUCTWORK. 2. SHEET METAL DUCT, SIZE AS NOTED ON PLANS. 3. DUCT STRAP HANGER. 4. STATIC BOOT SIMILAR TO EXCEPT NO DAMPER. 5. SHEET METAL DUCT, FULL SIZE OF GRILLE NECK SIZE. CONNECT AND SEAL DUCT TO GRILLE, SEAL CLASS A. 6. FLEXIBLE DUCT CONNECTOR. 7. CEILING T-BAR SUPPORT (FOR LAY-IN APPLICATIONS). COORDINATE AND VERIFY T-BAR TYPE FOR COMPATIBILITY WITH GRILLE. 1 NOTES MOUNTING ANGLEBLADE DEFLECTION G TYPE AIR DEVICE SPIRAL DUCTWORK A. REFER TO AIR DISTRIBUTION DEVICES SCHEDULE FOR DUCT "MOUNTING ANGLE." B. AIR DEVICE "BLADE DEFLECTION" SHALL BE ADJUSTED TO DIRECT AIR PATH SUCH THAT AIR HITS CORNER WHERE THE WALL OR WINDOW MEETS THE FLOOR. GENERAL NOTES MOUNTING ANGLEB LA D E D E F L E C T IO N G TYPE AIR DEVICE AIR FLOW AIR FLOW AIRFLOWTURNING VANES SEE FLOOR PLAN FOR SPLIT DIMENSION MAIN SUPPLY DUCT MANUAL VOLUME DAMPER SUPPLY REGISTER ON BRANCH DUCT SQUARE ELBOW SHOWN PROVIDE ROUND ELBOW WHEN SHOWN ON PLANS AIR FLOW AIRFLOWW/4 OR 4" MIN. MAIN SUPPLY DUCT MANUAL VOLUME DAMPER BRANCH DUCT W BRANCH DUCT TAKE-OFF PLAN VIEWAIR SPLIT DUCT TAKE-OFF PLAN VIEW THE BRANCH DUCT TAKE-OFF MAY BE USED FOR UP TO 15% OF THE MAIN DUCT CFM, AND UP TO 40% WHEN THE MAIN DUCT VELOCITY IS 1000 FPM OR LESS. THE AIR SPLIT DUCT TAKE-OFF SHALL BE USED IN ALL OTHER CASES BRANCH DUCT PLAN VIEW W W/4 OR 4" MIN. PROVIDE MANUAL VOLUME DAMPER AT EACH BRANCH DUCT MAIN EXHAUST OR RETURN AIR FLOW 45 DEG.AIR FLOWAIR FLOW AIR FLOW EQUIPMENTAIR FLOW TYPICAL DUCTWORK TRANSITION WITH EQUIPMENT MOUNTED IN DUCT PLAN OR SIDE VIEW TYPICAL DUCTWORK TRANSITION PLAN OR SIDE VIEW NOTE: UNLESS OTHERWISE INDICATED ON PLANS, MAXIMUM ANGLES SHOWN SHALL APPLY. 30 DEG. MAX. AIR FLOW 15 DEG. MAX 15 DEG. MAX15 DEG. MAX. 30 DEG. MAX. 15 DEG. MAX. CONCENTRIC TRANSITIONS UNLESS SHOWN OTHERWISE ON PLANS 3 1 2 9 8 7 4 5 6 A. PAINT ALL EXTERIOR DUCTWORK AND DEVICES WITH TWO COATS OF ENAMEL. ALL EXTERIOR SHEET METAL SHALL BE "PAINT-GRIP" CONSTRUCTION. 1. 1/2" MESH BIRDSCREEN. 2. 2" WIDE x 1/8" THICK STEEL SUPPORTS. 3. 3'-0" CLEARANCE TYPICAL ALL VENTS. 4. STRUCTURAL FRAMING FOR OPENING. COORDINATE REQUIRED OPENING DIMENSIONS. 5. SUPPORT RING. FASTEN TO DUCTWORK AND CHANNEL. 6. CHANNEL SUPPORT FROM ADJACENT JOISTS. 7. 16" HIGH CURB. 8. FLASHING COLLAR FASTEN TO DUCTS. 9. STORM COLLAR FASTEN TO DUCT..NOTES GENERAL NOTES 1 12"3 4 2 COUNTER FLASHING INSULATION ROOFING DUCT WALL 1. 12" HIGH INSULATED STEEL CURB. 2. PROVIDE PRESSURE TREATED RIGID WOOD BLOCK FRAME SAME THICKNESS AS ROOF INSULATION. BOLT TO CONCRETE ROOF DECK. 3. SHEET METAL SCREW. 4. CONCRETE ROOF DECK OPENING. COORDINATE REQUIRED OPENING SIZE..NOTES www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 11:15:24 AMM501 MECHANICAL DETAILS Sun King Spirits EEL JSN 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 CEILING DIFFUSER DUCT CONNECTION1 RETURN/EXHAUST GRILLE DUCT CONNECTION2 RETURN/EXHAUST GRILLE DUCT CONNECTION3 DUCT-MOUNTED GRILLE DETAIL4 SUPPLY DUCTWORK TAKE-OFFS5 EXHAUST OR RETURN BRANCH DUCTWORK6 DUCTWORK TRANSITIONS7 VENT DUCTS THRU ROOF8 FAN MOUNTING CURB9 No. Description Date www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 11:15:31 AMM701 MECHANICAL SCHEDULES Sun King Spirits EEL JSN 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 DUCT CONSTRUCTION, SEALING, AND INSULATION GENERAL NOTES: A. REFER TO SPECIFICATIONS FOR DUCT CONSTRUCTION: SHEET METAL DUCT; INTERIOR LINING; EXTERIOR INSULATION; FIBERGLASS DUCTBOARD; ETC. NOTES: 1. ROUND SHEET METAL RUN-OUTS TO AIR DEVICES DOWNSTREAM OF VAV BOXES SHALL BE EXTERNALLY INSULATED. 2. RETURN DUCTWORK WITHIN 15' OF AIR HANDLING UNIT SHALL BE INTERNALLY LINED. 3. WATERTIGHT SEAL. 4. FIRE WRAPPED, PER CODE REQUIREMENTS. 5. STAINLESS STEEL DUCTWORK. DUCT SYSTEM SUPPLY DUCTWORK +3" A 12 - S.P. CON- STRUCT. SEAL CLASS LEAKAGE CLASS S.M.A.C.N.A. CLASS. INTERNALLY LINED ● EXTERNAL INSULATION - - NOT INSULATED SEE NOTE DOUBLE WALL INSULATED RETURN DUCTWORK -2" A ●2- - TOILET OR GENERAL EXHAUST A -●--1" EXHAUST DUCTWORK - KITCHEN HOOD WELDED -4- - - 1 - -- -2" TRANSFER/RETURN AIR SOUND BOOT A - --1"3 RECT RND 24 24 6 12 12 24 12 HVAC DESIGN DATA GENERAL NOTES: A. OUTDOOR DESIGN CONDITIONS: 92°F DB SUMMER 74°F WB SUMMER 1°F DB WINTER NOTES: 1. "FLOATING" MEANS THERE IS NO ACTIVE CONTROL. SPACE NAME / TYPE °F DB INTERIOR DESIGN DATA SEE NOTE OFFICES 1 SUMMER WINTER 1 1 1 - % RH (NOTE 1) °F DB % RH 74 55 72 FLOATING 75 60 68 FLOATING - FLOATING 65 74 55 72 - - - - TOILET ROOMS MECHANICAL ROOMS ALL OTHER SPACES - FLOATING FLOATING B. DESIGN ALTITUDE: 850 FT. NOTES: 1. GRILLES SHALL BE DOUBLE DEFLECTION TYPE WITH (2) SETS OF FULLY ADJUSTABLE DEFLECTION BLADES. 2. 0° MOUNTING ANGLE, 0° BLADE DEFLECTION. 3. 20° MOUNTING ANGLE, 0° BLADE DEFLECTION. 4. PROVIDE RETURN AIR SOUND BOOT ON ALL RETURN GRILLES. GENERAL NOTES: A. ALL LAY-IN AIR DEVICES SHALL FIT IN 24"X24" LAY-IN CLG SYSTEM. VERIFY GRID TYPE AND COORDINATE AIR DEVICE COMPATIBILITY. B. FINISH KEY: "W.B.E." - WHITE BAKED ENAMEL; "E.C.L." - ETCHED CLEAR LACQUER OR ANODIZED; "C.C.B.A." - CUSTOM COLOR SELECTED BY ARCHITECT. C. SUPPLY AIR DIFFUSERS SHALL BE 4-WAY BLOW, UNLESS INDICATED OTHERWISE ON DRAWINGS. D. PROVIDE AUX. FRAMES FOR AIR DEVICES IN PLASTER, GYPSUM BOARD, TILE OR OTHER HARD SURFACES. AIR DISTRIBUTION DEVICES MARKDESCRIPTION MOUNTING TYPE MATERIAL FINISH OPPOSED BLADE DAMPER SQ-TO-RD NECK ADAPTOR BASIS OF DESIGN SEE NOTE LAY-IN SURFACE DUCT SPLINE SNAP-IN STEEL ALUMINUM STAINLESS STEEL W.B.E. E.C.L. C.C.B.A.MANUFACTURER MODEL A1 SQUARE PLAQUE DIFFUSER ● ● ●PRICE ASPD E1 SIDEWALL FIXED BLADE EXHAUST GRILLE ● ● ●PRICE 635 G1 SPIRAL DUCT GRILLE ● ● ●PRICE SDGE 2 G2 SPIRAL DUCT GRILLE ● ● ●PRICE SDGE 3 H1 SIDEWALL ADJ. BLADE SUPPLY GRILLE ● ● ●PRICE 620 1 J1 EGGCRATE RETURN GRILLE ● ● ●PRICE 80 4 J2 EGGCRATE EXHAUST GRILLE ● ● ●PRICE 80 J3 EGGCRATE FILTERED EXHAUST GRILLE ● ● ●PRICE 80FF R2 SIDEWALL FIXED BLADE RETURN GRILLE ● ● ●PRICE 635 NOTES: 1. SUSPENDED ABOVE CEILING. GENERAL NOTES: A. GAS HEATING. B. DX COOLING. C. MOTORS - 208V - 3PH, UNLESS NOTED OTHERWISE. D. VFD'S SHALL BE CONSTRUCTED AND LABELED FOR REQUIRED SCCR (SHORT CIRCUIT CURRENT RATING). COORDINATE WITH DIVISION 26. E. UNIT CONFIGURATIONS (SUPPLY FAN POSITION RELATIVE TO COOLING COIL) - "HDT" - HORIZONTAL DRAW THRU; "VDT" - VERTICAL DRAW THRU; "HBT" - HORIZONTAL BLOW THRU; "VBT" - VERTICAL BLOW THRU.... AIR HANDLING UNITS UNIT NUMBERLOCATION UNIT CONFIGURATIONAREA SERVED SUPPLY FAN COOLING COIL REHEAT COIL FINAL FILTER OUTSIDE AIR MISC. BASIS OF DESIGN SEE NOTE ROOM NAME ROOM NUMBER FAN SYSTEM NUMBER CFM (TOTAL) EXT / TOTAL STATIC PRESSURE (IN. W.C.) FAN QTY / WHEEL DIA. WHEEL TYPE MOTOR (HP EACH) VARIABLE FREQUENCY DRIVE (QTY) VIBRATION ISOLATOR TYPE MINIMUM FACE AREA (SQ. FT.) TOTAL CAPACITY (MBH) SENSIBLE CAPACITY (MBH) ENTERING AIR TEMPERATURE DB/WB (°F) LEAVING AIR TEMPERATURE DB/WB (°F) CAPACITY (MBH) ENTERING AIR TEMPERATURE DB (°F) LEAVING AIR TEMPERATURE DB (°F) THICKNESS / MERV MINIMUM FACE AREA (SQ. FT.) MAXIMUM CLEAN AIR PRESS. DROP (IN. W.C.) MINIMUM CFM ECONOMIZER MAXIMUM UNIT WEIGHT (LBS.)MANUFACTURER MODEL AHU-1 RESTROOM 204 HDT SECOND FLOOR SF-1 6,150 1.2/3.0 1/18" AF 5 1 INTERNAL 12 250.3 169.0 80.0/67.0 55.0/53.8 320 45.0 92.3 2" / 8 16.6 .75 2,000 ●2750 - - 1 NOTES: 1. INTEGRAL DISCONNECT 2. ECM MOTOR WITH MANUFACTURER SPEED CONTROL GENERAL NOTES: A. ALL FANS SHALL BE A.M.C.A. 211 AND 311 PERFORMANCE CERTIFIED AND SHALL BEAR THE A.M.C.A. LABEL. B. MOTOR HORSEPOWERS LISTED SHALL BE CONSIDERED MINIMUM. C. COORDINATE STEEL FRAMING AROUND ROOF OPENING WHERE REQUIRED FOR DECK SUPPORT, AND WALL LINTELS FOR WALL OPENINGS. D. ALL MOTORS SHALL BE EC TYPE UNLESS OTHERWISE NOTED. E. VFD'S SHALL BE CONSTRUCTED AND LABELED FOR REQUIRED SCCR (SHORT CIRCUIT CURRENT RATING). COORDINATE WITH DIVISION 26. FANS MARKDESCRIPTION SERVICE CFM STATIC PRESSURE (IN. W.C.) MAXIMUM SONESMOTOR APPROX. WEIGHT (LBS.) VIBRATION ISOLATOR TYPE BASIS OF DESIGN SEE NOTE HORSEPOWER VOLTAGE - PHASEMANUFACTURER MODEL EF-1 DOWNBLAST CENTRIFUGAL EXHAUST RESTROOMS 1,200 1.25" 15 1/2 120-1 60 GREENHECK G-123-VG 1, 2 EF-2 UPBLAST CENTRIFUGAL EXHAUST KITCHEN HOODS 1,800 1.5" 15 1 120-1 90 GREENHECK CUE-141-VG 1, 2 EF-3 UPBLAST CENTRIFUGAL EXHAUST PIZZA OVEN HEAT 400 0.75" 10 1/4 120-1 50 GREENHECK CUE-095-VG 1, 2 EF-4 DOWNBLAST CENTRIFUGAL EXHAUST MILL ROOM 175 0.75" 10 1/4 120-1 50 GREENHECK G-097-VG 1, 2 EF-5 DOWNBLAST CENTRIFUGAL EXHAUST DISTILLERY 2,000 1.3" 20 1 120-1 80 GREENHECK G-143-VG 1, 2 EF-6 DOWNBLAST CENTRIFUGAL EXHAUST FORK TRUCK CHARGE 550 0.75" 10 1/4 120-1 50 GREENHECK G-098-VG 1, 2 NOTES: 1. NOT USED. GENERAL NOTES: A. COOLING CAPACITIES BASED ON 95°F AMBIENT AIR TEMPERATURE. B. NATURAL GAS DELIVERY PRESSURE TO UNIT IS 14" W.C. PROVIDE SECONDARY REGULATOR IF REQ'D FOR UNIT OPERATION. C. ELECTRIC SERVICE - SINGLE POINT POWER SERVICE CONNECTION TO UNIT. ADEQUACY OF LISTED CIRCUIT SIZE MUST BE VERIFIED BY H.C. AND UNIT SUPPLIER. COST FOR INCREASE OR CHANGE OF ELECTRIC SERVICE FOR EQUIPMENT SELECTED SHALL BE BORNE BY H.C. THIS SHALL INCLUDE LUG SIZE AND QUANTITY REQUIREMENTS. D. UNIT CONFIGURATIONS (SUPPLY FAN POSITION RELATIVE TO COOLING COIL) - "HDT" - HORIZONTAL DRAW THRU; "VDT" - VERTICAL DRAW THRU; "HBT" - HORIZONTAL BLOW THRU; "VBT" - VERTICAL BLOW THRU. REFER TO DRAWINGS FOR LAYOUT. E. HEATING L.A.T. IS BASED ON FULL UNIT CFM AT LISTED E.A.T. AND MBH OUTPUT. ROOFTOP HEATING & COOLING UNITS - DX/GAS FIRED UNIT NUMBER NOMINAL TONS UNIT CONFIGURATION AREA SERVED SUPPLY FAN COOLING SECTION HEATING SECTION FINAL FILTERS OUTSIDE AIR MISCELLANEOUS ELECTRICAL SERVICE BASIS OF DESIGN SEE NOTE CFM (TOTAL) EXTERNAL / TOTAL STATIC PRESSURE (IN. W.C.) FAN QTY / WHEEL TYPE MOTOR (HP EACH) VARIABLE FREQUENCY DRIVE (QTY) VIBRATION ISOLOATOR TYPEDX-COOLING COIL CONDENSING SECTION HEATING CAPACITY (MBH OUTPUT) ENTERING AIR TEMPERATURE DB (°F) LEAVING AIR TEMPERATURE DB (°F) (NOTE F) GAS INPUT MIN./MAX. (CFH) THICKNESS / MERV MAX. CLEAN AIR PRESSURE DROP (IN. W.C.) MINIMUM CFM ECONOMIZER ENERGY RECOV. SECTION (REFER TO SEP. SCHED.) HOT GAS REHEAT AIR BLENDER (REFER TO SEP. SCHED.) INTERNAL LIGHTS SERVICE RECEPTACLE UVGI (NOTE G) MINIMUM CURB HEIGHT MAXIMUM UNIT WEIGHT INCLUDING CURB (LBS) VOLTAGE - PHASE MINIMUM CIRCUIT AMPS MAXIMUM OVER CURRENT PROTECTION (AMPS) FUSED DISCONNECTMANUFACTURER MODEL MINIMUM FACE AREA (SQ. FT.) TOTAL CAPACITY (MBH) SENSIBLE CAPACITY (MBH) ENTERING AIR TEMPERATURE DB/WB (°F) LEAVING AIR TEMPERATURE DB/WB (°F) MAXIMUM AIR PRESSURE DROP (IN. W.C.) REFRIGERANT TYPEAIR-COOLED MINIMUM QUANTITY OF COMPRESSORS MINIMUM STAGES OF COOLING HOT GAS BYPASSRTU-1 10 HDT DISTILLERY 2,000 0.50/1.0 1/BC 4 1 INTERNAL 25 127.7 75.1 90.0/74.0 55.5/54.9 .5 R410A 2 5 ●160.0 0.0 74.1 200 2" / 13 1 2,000 ● ● ● ●14" 3,000 208-3 53.9 60 ●- - RTU-2 20 HDT FIRST FLOOR 7,490 1.0 / 4.0 1/BC 5 1 INTERNAL 40 248.7 150.5 80.0/67.0 61.7/57.1 .5 R410A 5 5 ●295.7 40.0 76.6 370 2" / 8 1.5 2,000 ● ● ● ●14" 3,000 208-3 178.2 225 ●- - NOTES: 1. MOUNTING HEIGHT TO BOTTOM OF UNIT, UNLESS NOTED... 2. COORDINATE LOCATION WITH ARCHITECT. GENERAL NOTES: A. HEATING CAPACITY BASED ON 60°F ENT. AIR B. ELECTRICAL SERVICE TO 3-PHASE UNITS SHALL BE 3-WIRE UNLESS NOTED OTHERWISE. C. 3-PHASE COIL LOADS SHALL BE DIVIDED EVENLY ACROSS EACH PHASE. D. VERIFY/COORDINATE CABINET DIMENSIONS, MOUNTING & RECESS REQUIREMENTS PRIOR TO ORDERING. E. RECESSED UNITS SHALL HAVE FOUR(4) SIDE OVERLAP... F. COORDINATE LINTELS IN MASONRY WALLS FOR FULL & SEMI-RECESSED UNIT WALL OPENINGS. G. WHEN APPLICABLE, REFER TO SPECIFICATIONS FOR VIBRATION ISOLATOR TYPES. ELECTRIC HEATING UNITS MARKDESCRIPTION MOUNTING CFMHEATI NG ELECTRICAL SERVICE APPROX. CABINET DIMENSIONS THERMOSTAT SEE NOTE KW VOLTAGE - PHASE AMPS INTEGRAL DISCONNECT WIDTH DEPTH HEIGHT MOUNTING HEIGHT (AFF, NOTE 1) UNIT MOUNTED WALL MOUNTEDEUH-1 PROPELLER UNIT HEATER WALL MOUNTED 650 10.0 208-3 28.0 ●19" 8" 22" 8'-0"●- 1 EUH-2 PROPELLER UNIT HEATER WALL MOUNTED 350 5.0 208-3 14.0 ●14" 8" 16" 8'-0"●- 1 EUH-3 PROPELLER UNIT HEATER WALL MOUNTED 350 5.0 208-3 14.0 ●14" 8" 16" 8'-0"●- 1 EWH-1 WALL UNIT HEATER WALL RECESSED 650 4.8 208-3 13.3 ●14.375" 3.5" 18.25" 0'-0"●- 2 ●- NOTES: 1. NOT USED GENERAL NOTES: A. COOLING CAPACITY BASED ON 95°F AMBIENT AIR TEMPERATURE. B. REFRIGERANT PIPING - SIZES LISTED ARE APPROX. CIRCUITING, SIZING, NUMBER OF PIPES AND CIRCUITS, ARRANGEMENT, ETC. SHALL BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. C. ELECTRIC SERVICE - SINGLE POINT POWER SERVICE CONNECTION. ADEQUACY OF LISTED CIRCUIT SIZES MUST BE VERIFIED BY CONTRACTOR AND UNIT SUPPLIER. COST FOR INCREASE OR CHANGE OF ELECTRIC SERVICE FOR EQUIPMENT SELECTED SHALL BE BORNE BY HVAC CONTRACTOR. AIR-COOLED CONDENSING UNITS MARK SERVICE NOMINAL CAPACITY (TONS) UNIT RATING (SEER) REFRIGERANT TYPECONDENSER FANS COMPRESSORS ELECTRICAL SERVICE DIMENSIONS MISC. BASIS OF DESIGN SEE NOTETYPE MIN. QTY. MOTOR (HP / WATTS, EACH) TYPE MIN. QTY. UNIT MCA MAX FUSE / BREAKER (AMPS) UNIT VOLTAGE - PHASE LENGTH WIDTH HEIGHT APPROX. WEIGHT (LBS.) LOW AMBIENT CONTROL HOT GAS BYPASS CRANKCASE HEATER CONCRETE PADMANUFACTURER MODEL ACCU-1 AHU-1 20 12.1 R410A DIRECT DRIVE 2 1.00 HP SCROLL 2 98 125 208-3 96" 48" 46" 1,000 - - - - - - NOTES: 1. NOT USED GENERAL NOTES: A. ROOF OPENING SIZES ARE APPROXIMATE. VERIFY SIZE AND COORDINATE. B. COORDINATE STEEL FRAMING AROUND ROOF OPENING, WHERE REQUIRED FOR DECK SUPPORT. GRAVITY ROOF VENTILATORS MARKDESCRIPTION CFM MAX. STATIC PRESSURE (IN. W.C.)NECK SIZE APPROX. HOOD SIZE APPROX. ROOF OPENING SIZE APPROX. WEIGHT (LBS.)BACKDRAFT DAMPER BASIS OF DESIGN SEE NOTE LENGTH WIDTH LENGTH WIDTH / DIAMETER HEIGHT MOTORIZED GRAVITYMANUFACTURER MODEL RAH-1 RELIEF HOOD 13640 .03 84" 60" 108" 93" 26" 90" X 66" 400 -●GREENHECK FGR NOTES: 1. BASIS OF DEISGN: PRICE RDV GENERAL NOTES: A. TYPES - "V.V.", VARIABLE VOLUME; "V.V.T.", VARIABLE VOL./TEMP. B. .5" MAXIMUM STATIC PRESSURE DROP THRU UNIT AT MAXIMUM CFM. AIR TERMINAL UNITS MARK TYPEMINIMUM INLET SIZE CFM SEE NOTE DIAMETER WIDTH HEIGHT MAXIMUM MINIMUMZD-1 V.V. 12" 1,200 400 1 ZD-2 V.V. 16" 2,080 650 1 ZD-3 V.V. 16" 1,920 650 1 ZD-4 V.V. 12" 825 400 1 DISTILLERY SUPPLY A - -+3"512 6 ●- DISTILLERY EXHAUST A -●--1"-524 12 NOTES: 1. NOT USED GENERAL NOTES: A. GAS DELIVERY PRESSURE IS 14" W.C. B. WHEN APPLICABLE, REFER TO SPECIFICATIONS FOR VIBRATION ISOLATOR TYPES. GAS-FIRED RADIANT HEATING UNITS MARKDESCRIPTION MOUNTING LOCATION GAS INPUT (CFH) HEATING OUTPUT (MBH)ELECT RICAL SERVI CE DIMENSIONS THERMOS TAT BASIS OF DESIGN SEE NOTEROOM NAME VOLTAGE - PHASE GAS CONNECTION SIZE VENT OUTLET SIZE COMB. AIR INLET SIZE APPROX. OPERATING WEIGHT (LBS) UNIT MOUNTED WALL MOUNTED LINE VOLTAGEMANUFACTURER MODEL RH-1 GAS-FIRED UNIT HEATER OVERHEAD EXTERIOR DINING 100 1,000 120-1 0.75" 4" 4" 175 ●-●ROBERTS GORDON COMPLETE HED - RH-2 GAS-FIRED UNIT HEATER OVERHEAD EXTERIOR DINING 125 1,250 120-1 0.75" 4" 4" 225 ●-●ROBERTS GORDON COMPLETE HED - No. Description Date