Loading...
HomeMy WebLinkAbout07_2017-03-30 - Sun King Distillery - CDs - DIV-26 DWGSFIRE ALARM SYMBOLS FIRE ALARM BELL & SIGNAL LIGHT (80" AFF), (# WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOT SHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS. ELECTRICAL SYMBOLS EXISTING OUTLET OR DEVICE TO REMAIN. MAINTAIN EXISTING CIRCUITING. DASH SYMBOL INDICATES PARTICULAR OUTLET OR DEVICE TO BE REMOVED AND CIRCUITRY MADE CONTINUOUS WHERE REQUIRED. ELECTRICAL CONNECTION. 20A-125V DUPLEX RECEPTACLE, NEMA 5-20R (18" MH UNLESS NOTED OTHERWISE). 20A-125V SINGLE RECEPTACLE, NEMA 5-20R (18" MH UNLESS NOTED OTHERWISE). SPECIAL PURPOSE RECEPTACLE. REFER TO NOTE ON PLAN. 20A-125V DOUBLE DUPLEX RECEPTACLE. NEMA 5-20R, (18" MH UNLESS NOTED OTHERWISE) TWO GANG ASSEMBLY. 20A-125V DUPLEX RECEPTACLE, NEMA 5-20R WITH BOTTOM OUTLET CONTROLLED BY WALL SWITCH. (18" MH UNLESS NOTED OTHERWISE). 20A-125V DUPLEX RECEPTACLE, NEMA 5-20R, WITH GROUND FAULT CIRCUIT INTERRUPTER (18" MH UNLESS NOTED OTHERWISE). 20A-125V WEATHERPROOF DUPLEX RECEPTACLE, NEMA 5-20R (HORIZONTAL 18" MH UNLESS NOTED OTHERWISE) WITH TAYMAC #10310 STANDARD COVER, VERTICAL MOUNT. 20A-125V WEATHERPROOF DUPLEX RECEPTACLE, NEMA 5-20R WITH GROUND FAULT CIRCUIT INTERRUPTER (18" MH UNLESS NOTED OTHERWISE), WITH TAYMAC #20310 STANDARD COVER, VERTICAL MOUNT. 20A-125V DUPLEX RECEPTACLE, NEMA 5-20R, ON EMERGENCY POWER (18" MH UNLESS NOTED OTHERWISE). 20A-125V POWERLOCK GROUNDING TYPE RECEPTACLE, HOSPITAL USE (66" MH UNLESS NOTED OTHERWISE). 20A-125V DUPLEX PEDESTAL TYPE FLOOR RECEPTACLE, NEMA 5-20R, IN HUBBELL BA-2527 FLOOR BOX WITH SA-2525 COVERPLATE AND SC-3091 HOUSING. PROVIDE CARPET FLANGE WHERE REQUIRED. 20-125V DUPLEX RECEPTACLE, NEMA 5-20R, WITH ISOLATED GROUND (18" MH UNLESS NOTED OTHERWISE). 20A-125/250V-1PH-4W SINGLE RECEPTACLE, NEMA 14-20R (18" MH UNLESS NOTED OTHERWISE). 30A-125/250V-1PH-4W SINGLE RECEPTACLE, NEMA 14-30R (18" MH UNLESS NOTED OTHERWISE). 50A-125/250V-1PH-4W SINGLE RECEPTACLE, NEMA 14-50R (18" MH UNLESS NOTED OTHERWISE). 20A-250V-3PH-4W SINGLE RECEPTACLE, NEMA 15-20R (18" MH UNLESS NOTED OTHERWISE). 30A-250V-3PH-4W SINGLE RECEPTACLE, NEMA 15-30R (18" MH UNLESS NOTED OTHERWISE). 50A-250V-3PH-4W SINGLE RECEPTACLE, NEMA 15-50R (18" MH UNLESS NOTED OTHERWISE). JUNCTION BOX. MULTI-OUTLET RECEPTACLES ASSEMBLY, NEMA 5-15R (SINGLE OUTLETS ON 18" CENTERS) (46" MH UNLESS NOTED OTHERWISE). CLOCK HANGER OUTLET, SINGLE NEMA 5-15R RECESSED IN COVER PLATE (84" MH UNLESS NOTED OTHERWISE). SINGLE POLE SWITCH (46" MH UNLESS NOTED OTHERWISE). TWO POLE WALL SWITCH (46" MH UNLESS NOTED OTHERWISE). MULTI-WAY WALL SWITCH, # INDICATES NUMBER OF WAYS (46" MH UNLESS NOTED OTHERWISE). SWITCH WITH NEON PILOT LIGHT. ONE-GANG ASSEMBLY (46" MH UNLESS NOTED OTHERWISE). KEY OPERATED WALL SWITCH (46" MH UNLESS NOTED OTHERWISE). LIGHTING DIMMER SWITCH (46" MH UNLESS NOTED OTHERWISE) 1000 WATTS UNLESS OTHERWISE INDICATED. SWITCH WITH RECEPTACLE (46" MH UNLESS NOTED OTHERWISE) STANDARD TWO-GANG ASSEMBLY OF SWITCH AND RECEPTACLE. FLUSH FRACTIONAL HORSEPOWER MOTOR STARTER WITH NEON PILOT LIGHT. ONE-GANG ASSEMBLY (46" MH UNLESS NOTED OTHERWISE). HP RATED WALL SWITCH (46" MH UNLESS NOTED OTHERWISE). DISCONNECT SWITCH. MOTOR STARTER. COMBINATION MOTOR STARTER AND DISCONNECT SWITCH. ELECTRIC MOTOR. ELECTRICAL PANEL OR SWITCHBOARD PER DRAWINGS. PULL BOX. LINE VOLTAGE THERMOSTAT. UNIT HEATER. FAN COIL. ELECTRIC BASEBOARD HEATER. AIR CONDITIONER. CONDENSING UNIT. UNIT VENTILATOR. CORD REEL. POWER POLE. PHOTOELECTRIC SENSOR. LIGHTING CONTACTOR. CEILING MOUNTED OCCUPANCY SENSOR. WALL MOUNTED OCCUPANCY SENSOR. CEILING MOUNTED DAYLIGHT SENSOR. OCCUPANCY SENSOR POWER PACK. FIRE ALARM SPEAKER & SIGNAL LIGHT (80" AFF), (# WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOT SHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS. FIRE ALARM CHIME & SIGNAL LIGHT (80" AFF), (# WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOT SHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS. FIRE ALARM HORN & SIGNAL LIGHT (80" AFF), (# WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOT SHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS. FIRE ALARM SIGNALING LIGHT (80" AFF), (# WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOT SHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS. FIRE ALARM MANUAL STATION (46" MH UNLESS NOTED OTHERWISE). SUBSCRIPT "K" INDICATES KEY OPERATED. CEILING MOUNTED SMOKE DETECTOR. CEILING MOUNTED HEAT DETECTOR. DUCT MOUNTED SMOKE DETECTOR. SUBSCRIPT "S" INDICATES SUPPLY. SUBSCRIPT "R" INDICATES RETURN. DUCT MOUNTED HEAT DETECTOR. SUBSCRIPT "S" INDICATES SUPPLY. SUBSCRIPT "R" INDICATES RETURN. ELECTRIC RELEASE DOOR CLOSER. ELECTRO-MAGNETIC DOOR HOLDER. WATER FLOW SWITCH. VALVE SUPERVISORY SWITCH. DUCT MOUNTED DETECTOR REMOTE TEST STATION AND ALARM INDICATOR LIGHT. SUBSCRIPT "W" INDICATES WALL MOUNTED. SMOKE DAMPER. FIRE FIGHTER'S TELEPHONE (60" MH UNLESS NOTED OTHERWISE). PUSHBUTTON (46" MH UNLESS NOTED OTHERWISE) EDWARDS 852 (120 VOLT). BUZZER (90" MH UNLESS NOTED OTHERWISE) EDWARDS 340-A (120 VOLT). 4" DIAMETER (90" MH UNLESS NOTED OTHERWISE) EDWARDS "ADAPTABEL" (120 VOLT). GF WP WP/GF EM T IG 20A 30A 50A 20A 50A 30A J 2 # P K DM R H UH FC AC CU UV PP OS OS DS OP PC T F 15 F 15 F 15 F 15 15 S F CEILING MOUNTED FIRE ALARM SPEAKER. KF S H C D FS V R W SD FT B PRESSURE SWITCH. ADDRESSABLE MODULE. SUBSCRIPT "I" INDICATES INPUT. SUBSCRIPT "C" INDICATES CONTROL. POST INDICATOR VALVE. KNOX BOX. PS AM C/I PIV K FIRE ALARM CONTROL PANEL. 20A-125V DUPLEX RECEPTACLE, NEMA 5-20R (46" MH UNLESS NOTED OTHERWISE). C M CR LC P/B H S S/R S/R ELAPSED TIME INDICATOR CLOCK (90" MH UNLESS NOTED OTHERWISE) WITH RESET SWITCH (46" MH UNLESS NOTED OTHERWISE). INTERCOM SYSTEM DESK MOUNTED MASTER CONTROL STATION. SUBSCRIPT "W" INDICATES WALL MOUNT (46" MH UNLESS NOTED OTHERWISE). INTERCOM STAFF STATION (46" MH UNLESS NOTED OTHERWISE). INTERCOM HORN TYPE SPEAKER (84" MH UNLESS NOTED OTHERWISE). INTERCOM SPEAKER FLUSH MOUNT IN CEILING. I M H S FACP DUCT HEATER.H DH H EB LOW-VOLTAGE MOMENTARY WALL SWITCH (46" MH UNLESS NOTED OTHERWISE).L TECHNOLOGY SYMBOLS WITH ELEC. REQUIREMENTS P WALL MOUNTED PHONE OUTLET (46" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. JACKS, FACEPLATE AND CABLE PER DIV 27. REFER TO FACEPLATE DETAILS. XR WALL MOUNTED AV OUTLET (84" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT PER DIV 26. REFER TO FACEPLATE DETAILS. JACKS, FACEPLATE AND CABLING PER DIV 27. SUBSCRIPT "X" INDICATES ALTERNATE CONFIGURATION. XV WALL MOUNTED AV OUTLET (44" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT PER DIV 26. REFER TO FACEPLATE DETAILS. JACKS, FACEPLATE AND CABLING PER DIV 27. SUBSCRIPT "X" INDICATES ALTERNATE CONFIGURATION. CONDUIT SLEEVE / FIRE RATED SLEEVE ASSEMBLY THRU WALL (1-2" SLEEVE UNLESS NOTED OTHERWISE) PER DIV 26. J TELECOM BOX AND CONDUIT PER DIV 26, REFER TO PLANS. WALL MOUNTED VOICE/DATA OUTLET (18" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT(S) TO ABOVE CORRIDOR CEILING PER DIV 26. JACKS, FACEPLATE AND CABLE PER DIV 27. REFER TO FACEPLATE DETAILS. XI WALL MOUNTED AV OUTLET (18" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUITS TO ABOVE ACCESSIBLE CEILING PER DIV 26. REFER TO FACEPLATE DETAILS. JACKS, FACEPLATE AND CABLING PER DIV 27. SUBSCRIPT "X" INDICATES ALTERNATE CONFIGURATION. AP WALL MOUNTED WIRELESS ACCESS POINT (96” MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. WAP AND CABLE PER DIV 27. ABBREVIATIONS AAP - AREA ALARM PANEL - MEDICAL GAS ACC - ACCESS ADJ - ADJUSTABLE AF - ARC FAULT CIRCUIT INTERRUPTER AFCI - ARC FAULT CIRCUIT INTERRUPTER AFF - ABOVE FINISHED FLOOR TO BOTTOM OF ITEM AFG - ABOVE FINISHED GRADE TO BOTTOM OF ITEM ALT - ALTERNATE AP - ACCESS PANEL APPROX - APPROXIMATE ARCH - ARCHITECT OR ARCHITECTURAL ASSY - ASSEMBLY ATS - AUTOMATIC TRANSFER SWITCH BLDG - BUILDING BOE - BOTTOM OF EQUIPMENT BOT - BOTTOM BTWN - BETWEEN CFCI - CONTRACTOR FURNISHED CONTRACTOR INSTALLED CKT - CIRCUIT CLG - CEILING CMU - CONCRETE MASONRY UNIT CONN - CONNECT OR CONNECTION CONTR - CONTRACTOR CORR - CORRIDOR CTR - CENTER D - DEPTH DET - DETAIL DIA - DIAMETER DIM - DIMENSION DIV - DIVISION DN - DOWN DWG - DRAWING EA - EACH EC - ELECTRICAL CONTRACTOR (DIVISION 26) EJ - EXPANSION JOINT ELEC - ELECTRICAL ELEV - ELEVATION OR ELEVATOR EM - EMERGENCY EQ - EQUAL EQS - EQUIPMENT SUPPLIER EQUIP - EQUIPMENT ETR - EXISTING TO REMAIN EX - EXISTING EXP - EXPANSION EXT - EXTERIOR FCE - FIRE CONTROL EQUIPMENT FF - FINISHED FLOOR ELEVATION FLR - FLOOR FSC - FIRE SUPPRESSION CONTRACTOR (DIVISION 21) FT - FEET FTG - FOOTING GC - GENERAL CONTRACTOR GF - GROUND FAULT CIRCUIT INTERRUPTER GFCI - GROUND FAULT CIRCUIT INTERRUPTER OR GOVERNMENT FURNISHED CONTRACTOR INSTALLED GFFT - GROUND FAULT FEED THRU HC - HVAC CONTRACTOR (DIVISION 23) HP - HORSE POWER OR HIGH POINT HVAC - HEATING, VENTILATING, AND AIR CONDITIONING ID - INSIDE DIAMETER IN - INCHES KEC - KITCHEN EQUIPMENT CONTRACTOR L - LENGTH LBS - POUNDS MAP - MASTER ALARM PANEL (MEDICAL GAS) MAX - MAXIMUM MEZZ - MEZZANINE MFR - MANUFACTURER MH - MANHOLE OR MOUNTING HEIGHT TO CENTER LINE OF ITEM MIN - MINIMUM OR MINUTE MISC - MISCELLANEOUS MTD - MOUNTED MTG - MOUNTING NIC - NOT IN CONTRACT NOM - NOMINAL NTS - NOT TO SCALE OD - OUTSIDE DIAMETER OFCI - OWNER FURNISHED CONTRACTOR INSTALLED OFOI - OWNER FURNISHED OWNER INSTALLED PC - PLUMBING CONTRACTOR (DIVISION 22) PLBG - PLUMBING RAD - RADIUS REC - RECESSED REQD - REQUIRED RI - ROUGH-IN S - SURFACE MOUNTED SC - SECURITY CONTRACTOR SCH - SCHEDULE SHT - SHEET SMS - SECURITY MANAGEMENT SYSTEM SPEC - SPECIFICATIONS SQ - SQUARE SS - STAINLESS STEEL STD - STANDARD STRUC - STRUCTURAL OR STRUCTURE SUC - SITE UTILITY CONTRACTOR TC - TECHNOLOGY CONTRACTOR TEMP - TEMPERATURE TOE - TOP OF EQUIPMENT TYP - TYPICAL UNO - UNLESS NOTED OTHERWISE VFD - VARIABLE FREQUENCY DRIVE VOL - VOLUME W/ - WITH W/0 - WITHOUT WP - WEATHERPROOF ZVC - ZONE VALVE CABINET 1 E2 B E2 DETAIL: B = DETAIL DESIGNATION E2 = SHEET WHERE DETAIL IS LOCATED SECTION: 1 = SECTION DESIGNATION E2 = SHEET WHERE SECTION IS LOCATED PLAN NOTE. APPLIES ONLY TO THE SHEET WHICH IT IS SHOWN. DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL. GENERAL FLOOR PLAN NOTES WIRE & CONDUIT IN WALL OR ABOVE CEILING. WIRE & CONDUIT IN OR BELOW SLAB OR GRADE. EACH ARROWHEAD REPRESENTS ONE COMPLETE CIRCUIT; "X" DENOTES PANEL NAME; NUMBER(S) DENOTES CIRCUIT(S). LADDER TRAY, 12" x 4" DEEP UNLESS NOTED OTHERWISE. CONDUIT FOR DATA CIRCUITRY.DAT WIRE & CONDUIT FOR FIRE ALARM CIRCUITRY.FA WIRE & CONDUIT FOR NURSE CALL CIRCUITRY.NC EXISTING WIRE & CONDUIT TO REMAIN.EX CONDUIT TO BE REMOVED. WIRE & CONDUIT FOR NIGHT LIGHT CIRCUITRY.NL CONDUIT FOR PHONE CIRCUITRY.PHO WIRE & CONDUIT FOR SECURITY SYSTEM CIRCUITRY.SEC WIRE RUN IN SURFACE WIREWAY.W CABLE MANAGEMENT SYSTEM PATHWAY.CM X - 1,2 WIRE & CONDUIT FOR EMERGENCY CIRCUITRY.EM WIRE & CONDUIT FOR SOUND SYSTEM CIRCUITRY.S WIRE & CONDUIT FOR INTERCOM SYSTEM CIRCUITRY.I WIRE & CONDUIT FOR TELEVISION SYSTEM CIRCUITRY.TV 3 3 LUMINAIRE SYMBOLS LIGHTING FIXTURE. CAPITAL LETTER DENOTES FIXTURE TYPE, LOWER CASE LETTER DENOTES SWITCHING ARRANGEMENT. LIGHTING FIXTURE ON NIGHT LIGHT OR BATTERY CIRCUIT. EXIT LIGHTING FIXTURE, ARROWS AS INDICATED. A a WIREMOLD RACEWAY, AS NOTED ON PLANS. CABLE TRAY, 12" x 4" DEEP UNLESS NOTED OTHERWISE. 4" 4" 4" 3 3 20A-125V DUPLEX RECEPTACLE, NEMA 5-20R WITH 2 INTEGRAL USB CHARGERS (18" MH UNLESS NOTED OTHERWISE). NOTE: ALL SYMBOLS AND ABBREVIATIONS ARE SUBJECT TO MODIFICATIONS ON OTHER DRAWINGS. ALL SYMBOLS OR ABBREVIATIONS MIGHT NOT NECESSARILY BE USED ON THIS PROJECT. 20A-125V DUPLEX RECEPTACLE, NEMA 5-20R, IN HUBBELL BA-2527 FLUSH FLOOR BOX WITH ROUND SA-3925 COVERPLATE. PROVIDE CARPET FLANGE WHERE REQUIRED. TECHNOLOGY FLOOR BOX PER DIV 26. PROVIDE APPROPRIATE CONNECTOR PLATE AND HINGED COVER. "#" INDICATES OUTLET TYPE. SUBSCRIPT "X" INDICATES ALTERNATE CONFIGURATION. REFER TO FACEPLATE DETAILS.#X www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 11:25:09 AME001 SYMBOLS, ABBREVIATIONS & INDEX Sun King Spirits JB KAS 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 No. Description Date ELECTRICAL SHEET INDEX Sheet Description E001 SYMBOLS, ABBREVIATIONS & INDEX E002 SINGLE LINE DIAGRAM & PANEL SCHEDULES E003 ELECTRICAL SCHEDULES E004 ELECTRICAL DETAILS E201 FIRST FLOOR LIGHTING PLAN E202 SECOND FLOOR LIGHTING PLAN E301 FIRST FLOOR POWER & SYSTEMS PLAN E302 SECOND FLOOR POWER & SYSTEMS PLAN E303 ROOF POWER PLAN M 5432 1 2 3 4 5 6 7 8 1 6 1 2 POWER CO. X'FMR 12,470V TO 208Y/120V POWER CO. SOURCE 12470Y/7400V CT'S BY POWER CO. POWER CO. METER 2" C.MAIN PANEL MDP DISTRIBUTION PANEL 1DP 1000A, 208Y/120V-3Ø-4W 800A, 208Y/120V-3Ø-4W "1L1""1L2""1L3""1L4""2L1" SERVICE SPD N G REMOVABLE LINK MAIN BUILDING GROUND BAR CONCRETE ENCASED ELECTRODE GROUND RODS BUILDING STEEL #3/0 METALLIC WATER PIPE SEE PANEL SCHEDULE FOR MECHANICAL LOADS 1 3 4 24 3 4 5 6 7 8 4 3 www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 11:25:13 AME002 SINGLE LINE DIAGRAM & PANEL SCHEDULES Sun King Spirits JB KAS 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 SINGLE-LINE DIAGRAM1 312.10 kVA TOTAL CONNECTED ESTIMATED DEMAND NOTES:SEE SINGLE-LINE DIAGRAM FOR FEEDER SIZING 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 1L4 1.16 kVA 250 A 2 60 A 5 1L3 0.98 kVA 250 A 2 60 A 4 1L2 1.01 kVA 250 A 2 60 A 3 2L1 27.81 kVA 250 A 3 225 A 2 1L1 40.74 kVA 250 A 3 225 A 1 1DP 240.37 kVA 800 A 3 800 A CKT CIRCUIT DESCRIPTION APPROX. CONNECTED LOAD FRAME SIZE POLES TRIP SETTING BREAKER TYPE NUMBER OF CONDUCTORS WIRE SIZE GROUND SIZE CONDUIT SIZE SEE NOTE Feeder Size:Spec. Ref. #: Voltage:120/208 Wye-3PH-4W Mains Rating:1000 A Supply From:Enclosure:NEMA 1 Mains Type:MCB Location:Elec. 111 Mounting:SURFACE A.I.C. Rating:42K DISTRIBUTION PANEL: MDP 40.76 kVA 32.79 kVA (91 A) TOTAL CONNECTED ESTIMATED DEMAND Notes: Total Load:11.89 kVA 13.90 kVA 14.96 kVA 83 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 84 81 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 82 79 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 80 77 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 78 75 RECEPTACLES 20 A 1 180 VA 0 VA 1 20 A SPARE 76 73 RECEPTACLES 20 A 1 480 VA 830 VA 1 20 A RECEPTACLES 74 71 RECEPTACLES 20 A 1 720 VA 1000... 1 20 A TVS 72 69 RECEPTACLES 20 A 1 1100... 1000... 1 20 A TVS 70 67 RECEPTACLES 20 A 1 720 VA 1000...1 20 A BAR TVS 68 65 BAR RECEPTACLES 20 A 1 1440... 1500... 1 20 A SINK 66 63 RH-1,2 20 A 1 240 VA 1500... 1 20 A SINK 64 61 RCP-1 20 A 1 0 VA 1500...1 20 A SINK 62 59 ROM-1,2 20 A 1 2300... 1500... 1 20 A SINK 60 57 ROP-1,2 20 A 1 1590... 1500... 1 20 A SINK 58 55 RECEPTACLES 20 A 1 720 VA 1500...1 20 A SINK 56 53 RECEPTACLES 20 A 1 720 VA 360 VA 1 20 A RECEPTACLES 54 51 -- -- -- 0 VA 1260... 1 20 A RECEPTACLES 52 49 -- -- -- 0 VA 900 VA 1 20 A RECEPTACLES 50 47 DISTILLERY 20 A 3 0 VA 360 VA 1 20 A RECEPTACLES 48 45 -- -- -- 817 VA 180 VA 1 20 A FREEZER 46 43 -- -- -- 817 VA 180 VA 1 20 A COOLER 44 41 GRAIN MTR 20 A 3 817 VA 180 VA 1 20 A COOLER 42 39 -- -- -- 0 VA 360 VA 1 20 A RECEPTACLES 40 37 -- -- -- 0 VA 360 VA 1 20 A RECEPTACLES 38 35 MILL MACHINE 20 A 3 0 VA 540 VA 1 20 A RECEPTACLES 36 33 FERMENTERS 20 A 1 0 VA 1080... 1 20 A RECEPTACLES 34 31 RO SYSTEM 20 A 1 0 VA 540 VA 1 20 A RECEPTACLES 32 29 IDF 20 A 1 360 VA 360 VA 1 20 A RECEPTACLES 30 27 IDF 20 A 1 360 VA 720 VA 1 20 A RECEPTACLES 28 25 IDF 20 A 1 360 VA 0 VA 1 20 A SPARE 26 23 IDF 20 A 1 360 VA 0 VA 1 20 A SPARE 24 21 RECEPTACLES 20 A 1 360 VA 500 VA 1 20 A FACP 22 19 LIGHTING 20 A 1 280 VA 0 VA 1 20 A BAR LTG 20 17 LIGHTING 20 A 1 1272... 126 VA 1 20 A BAR LTG 18 15 LIGHTING 20 A 1 149 VA 418 VA 1 20 A BAR LTG 16 13 LIGHTING 20 A 1 315 VA 180 VA 1 20 A EXTERIOR LTG 14 11 LIGHTING 20 A 1 0 VA 174 VA 1 20 A LIGHTING 12 9 LIGHTING 20 A 1 0 VA 4 VA 1 20 A LIGHTING 10 7 LIGHTING 20 A 1 962 VA 0 VA 1 20 A LIGHTING 8 5 LIGHTING 20 A 1 499 VA 371 VA 1 20 A LIGHTING 6 3 EXTERIOR LTG 20 A 1 468 VA 112 VA 1 20 A ELEV LTG 4 1 EM / EXIT LTG 20 A 1 65 VA 180 VA 1 20 A ELEV PIT 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Voltage:120/208 Wye-3PH-4W Mains Rating:225 A Supply From:MDP Enclosure:Type 1 Mains Type:MLO Location:Elec. 111 Mounting:Surface A.I.C. Rating:42K Panel: 1L1 27.81 kVA 23.23 kVA (64 A) TOTAL CONNECTED ESTIMATED DEMAND Notes: Total Load:9.56 kVA 9.31 kVA 8.94 kVA 59 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 60 57 RH-1 20 A 1 120 VA 0 VA 1 20 A SPARE 58 55 EF-6 20 A 1 696 VA 0 VA 1 20 A SPARE 56 53 EF-5 20 A 1 1056... 0 VA 1 20 A SPARE 54 51 EF-4 20 A 1 696 VA 0 VA 1 20 A SPARE 52 49 EF-3 20 A 1 528 VA 0 VA 1 20 A SPARE 50 47 EF-2 20 A 1 1056... 0 VA 1 20 A SPARE 48 45 EF-1 20 A 1 648 VA 180 VA 1 20 A RECEPTACLES 46 43 SINK 20 A 1 1500... 720 VA 1 20 A BAR RECEPTACLES 44 41 SINK 20 A 1 1500... 1500... 1 20 A SINK 42 39 PIZZA OVEN 20 A 1 180 VA 1500... 1 20 A SINK 40 37 RECEPTACLES 20 A 1 360 VA 1500...1 20 A SINK 38 35 RECEPTACLES 20 A 1 540 VA 0 VA 1 20 A BOILER 36 33 RECEPTACLES 20 A 1 720 VA 2080... 1 20 A RECEPTACLES 34 31 RECEPTACLES 20 A 1 680 VA 1400...1 20 A RECEPTACLES 32 29 RECEPTACLES 20 A 1 1212... 360 VA 1 20 A RECEPTACLES 30 27 RECEPTACLES 20 A 1 360 VA 1080... 1 20 A RECEPTACLES 28 25 RECEPTACLES 20 A 1 360 VA 360 VA 1 20 A IDF 26 23 RECEPTACLES 20 A 1 540 VA 360 VA 1 20 A IDF 24 21 RECEPTACLES 20 A 1 900 VA 180 VA 1 20 A ELEV RECEPTACLE 22 19 RECEPTACLES 20 A 1 720 VA 0 VA 1 20 A SPARE 20 17 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 18 15 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 16 13 LIGHTING 20 A 1 210 VA 0 VA 1 20 A LIGHTING 14 11 LIGHTING 20 A 1 140 VA 502 VA 1 20 A PERGOLA LTG 12 9 LIGHTING 20 A 1 184 VA 0 VA 1 20 A BAR LTG 10 7 LIGHTING 20 A 1 0 VA 173 VA 1 20 A BAR LTG 8 5 LIGHTING 20 A 1 172 VA 0 VA 1 20 A LIGHTING 6 3 LIGHTING 20 A 1 483 VA 0 VA 1 20 A LIGHTING 4 1 EM / EXIT LTG 20 A 1 35 VA 316 VA 1 20 A LIGHTING 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Voltage:120/208 Wye-3PH-4W Mains Rating:225 A Supply From:MDP Enclosure:Type 1 Mains Type:MLO Location:STAFF BREAK 211 Mounting:Flush A.I.C. Rating:22K Panel: 2L1 1.01 kVA 1.04 kVA (3 A) TOTAL CONNECTED ESTIMATED DEMAND Notes:THIS PANEL SERVES KITCHEN EQUIPMENT IN FOOD 1. PROVIDE BRANCH CIRCUITS AS COORDINATED WITH K.E.C. SUPPLIER. ALL 120V, 15A & 20A BRANCH CIRCUITS TO BE GF PROTECTED. PROVIDE SHUNT TRIP MAIN BREAKER AND INTERLOCK WITH FIRE SUPPRESSION SYSTEM. Total Load:0.47 kVA 0.54 kVA 0.00 kVA 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 RECEPTACLES 20 A 1 360 VA 180 VA 1 20 A EXH HOOD 4 1 LIGHTING 20 A 1 112 VA 360 VA 1 20 A RECEPTACLES 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Voltage:120/208 Wye-3PH-4W Mains Rating:60 A Supply From:MDP Enclosure:Type 1 Mains Type:MCB Location:Food 1 120 Mounting:Surface A.I.C. Rating:10K Panel: 1L2 0.98 kVA 1.01 kVA (3 A) TOTAL CONNECTED ESTIMATED DEMAND Notes:THIS PANEL SERVES KITCHEN EQUIPMENT IN FOOD 2. PROVIDE BRANCH CIRCUITS AS COORDINATED WITH K.E.C. SUPPLIER. ALL 120V, 15A & 20A BRANCH CIRCUITS TO BE GF PROTECTED. PROVIDE SHUNT TRIP MAIN BREAKER AND INTERLOCK WITH FIRE SUPPRESSION SYSTEM. Total Load:0.44 kVA 0.54 kVA 0.00 kVA 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 RECEPTACLES 20 A 1 360 VA 180 VA 1 20 A EXH HOOD 4 1 LIGHTING 20 A 1 84 VA 360 VA 1 20 A RECEPTACLES 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Voltage:120/208 Wye-3PH-4W Mains Rating:60 A Supply From:MDP Enclosure:Type 1 Mains Type:MCB Location:Food 2 115 Mounting:Surface A.I.C. Rating:10K Panel: 1L3 1.16 kVA 1.19 kVA (3 A) TOTAL CONNECTED ESTIMATED DEMAND Notes:THIS PANEL SERVES KITCHEN EQUIPMENT IN FOOD 3. PROVIDE BRANCH CIRCUITS AS COORDINATED WITH K.E.C. SUPPLIER. ALL 120V, 15A & 20A BRANCH CIRCUITS TO BE GF PROTECTED. PROVIDE SHUNT TRIP MAIN BREAKER AND INTERLOCK WITH FIRE SUPPRESSION SYSTEM. Total Load:0.44 kVA 0.72 kVA 0.00 kVA 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 RECEPTACLES 20 A 1 540 VA 180 VA 1 20 A EXH HOOD 4 1 LIGHTING 20 A 1 84 VA 360 VA 1 20 A RECEPTACLES 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Voltage:120/208 Wye-3PH-4W Mains Rating:60 A Supply From:MDP Enclosure:Type 1 Mains Type:MCB Location:Kitchen 113 Mounting:Surface A.I.C. Rating:10K Panel: 1L4 FEEDER SCHEDULE # SIZE SETS CONDUCTORS 1 1000A 3 3-#600 (AL), #3/0 G (CU), 4" C 2 800A 2 4-#600, # 1/0 G, 4" C 3 225A 1 4-#4/0, # 4 G, 2.5" C 4 60A 1 4-# 6, # 10 G, 1.25" C FAULT CURRENT SCHEDULE REF. POINT DESCRIPTION EQUIP. RATING AVAILABLE SHORT CIRCUIT AMPS 1 UTILITY X'FMR SECONDARY - 36,206 2 MDP 42KAIC 32,706 3 1L1 42KAIC 25,742 4 1L2 10KAIC 3,049 5 1L3 10KAIC 3,469 6 1L4 10KAIC 3,725 7 2L1 22KAIC 18,999 8 1DP 42KAIC 30,877 240.37 kVA TOTAL CONNECTED ESTIMATED DEMAND NOTES:SEE MOTORS, STARTERS, DISCONNECTS & CONTROLS SCHEDULE FOR CIRCUIT SIZING 20 19 COOLER 7.21 kVA 150 A 3 30 A 18 COOLER 7.21 kVA 150 A 3 30 A 17 COOLER 7.21 kVA 150 A 3 30 A 16 BRIDGE CRANE 2.80 kVA 150 A 3 20 A 15 FORK TRUCK 2.80 kVA 150 A 3 20 A 14 AIR COMP 5.50 kVA 150 A 3 20 A 13 EWH-1 5.04 kVA 150 A 3 20 A 12 EUH-3 5.04 kVA 400 A 3 20 A 11 EUH-2 5.04 kVA 150 A 3 20 A 10 EUH-1 10.09 kVA 150 A 3 40 A 9 ACCU-C3 1.87 kVA 150 A 3 20 A 8 ACCU-C2 3.46 kVA 150 A 3 20 A 7 ACCU-C1 10.09 kVA 150 A 3 40 A 6 ACCU-1 35.31 kVA 150 A 3 125 A 5 CH-1 34.23 kVA 150 A 3 125 A 4 AHU-1 2.74 kVA 150 A 3 20 A 3 RTU-2 64.13 kVA 250 A 3 225 A 2 RTU-1 19.45 kVA 150 A 3 60 A 1 ELEVATOR 11.17 kVA 400 A 3 40 A CKT CIRCUIT DESCRIPTION APPROX. CONNECTED LOAD FRAME SIZE POLES TRIP SETTING BREAKER TYPE NUMBER OF CONDUCTORS WIRE SIZE GROUND SIZE CONDUIT SIZE SEE NOTE Feeder Size:Spec. Ref. #: Voltage:120/208 Wye-3PH-4W Mains Rating:800 A Supply From:MDP Enclosure:NEMA 1 Mains Type:MLO Location:Elec. 111 Mounting:SURFACE A.I.C. Rating:42K DISTRIBUTION PANEL: 1DP No. Description Date www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 11:25:18 AME003 ELECTRICAL SCHEDULES Sun King Spirits JB KAS 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 NOTES: 1. 2. 3. 4. LUMINAIRE SCHEDULE MARK LAMPS LOAD (VA) FIXTURE VOLTAGEMANUFACTURER CATALOG NO. DESCRIPTION DIFFUSING MEDIA TRIM COLOR MOUNTING SIZE SEE NOTEQUANTITY VA / LINEAR FOOT DELIVERED LUMENS COLOR WHITE BLACK ALUMINUM BRONZE STANDARD SEE NOTES-SURFACE R-RECESSED SM-STEM MTD WM-WALL MTD C-CHAIN MTD UC-UNDER CAB CS-CEIL SURFACE DIAMETER WIDTH LENGTH DEPTH FLUORESCENT INCANDESCENT H.I.D. L.E.D.16 0 0 12" 48" 5.5" A1 X 3200 3000K 35 120 METALUX SERIES "22GR LED" HEAVY GAUGE STEEL HOUSING WITH FLUSH ALUMINUM TOOLESS DROP DOOR, RECESSED GRID MOUNTED LENSED TROFFER, INSTANT START ELECTRONIC MULTI-VOLTAGE BALLAST PRISMATIC ACRYLIC LENS ●R 24" 24" 3.75" A2 X 5100 3000K 58 120 METALUX SERIES "SNLED LENSED" 4" LED LINEAR LENSED STRIP FIXTURE. DIE-FORMED COLD ROLLED STEEL, BAKED WHITE ENAMEL FINISH. PRISMATIC ACRYLIC LENS ●P 4" 48" 5.5" B1 X 900 3000K 12 120 HALO SERIES "ML4" 4" LED DOWNLIGHT W/ ULTRA-SHALLOW HOUSING SEMI SPECULAR CLEAR ●R 4" 8.75" B2 X 1000 3000K 11 120 HALO SERIES "PD615" 6" LED DOWN LIGHT SEMI SPECULAR CLEAR ●R 6" 8.75" B3 X 1500 3000K 17 120 HALO SERIES "PD615" 6" LED DOWN LIGHT SEMI SPECULAR CLEAR ●R 6" 8.75" C1 X 5 3000K 0 120 CONTECH LIGHTING SERIES "TLT" LED TAPE LIGHT WITH RIGID CHANNEL, WET RATED SURFACE 1" 1" C2 X 743 3000K 80 120 LUMINAIRE LED THE STAIRLIGHTER "TSL93" DIE FORMED COLD ROLLED COATED STEEL. VANDAL RESISTANT, INTEGRAL OCCUPACY SENSOR FOR HI/LOW OPERATION W/ 2600 LUMEN SELF-CONTAINED 90-MIN EMERGENCY BATTERY PACK. ACRYLIC LENS WM 4" 36" 10" C3 3 8000 3000K 63 120 PHOENIX SERIES "LFXR" EXPLOSION PROOF INDUSTRIAL FLUORESCENT FIXTURE CLEAR ●C 12" 53" D1 X 390/390 3000K 6 120 ARCLUCE SERIES "TULA" LED SCONCE WITH UP/DOWNLIGHT TEMPERED GLASS ●WM 2" 4.801" D2 X 1250 3000K 13 120 LURALINE SERIES "RLM" SPUN ALUMINUM SHADE W/ EXTRUDED ARM AND CAST CANOPY WM 12" 17.125" 6" G1 X 2600 3000K 13 120 ARCLUCE SERIES "DUEDIECI" ACCENT FLOOD FOR LOGO WM H1 X 5882 3000K 56 120 METALUX SERIES "4VT2" INDUSTRIAL LED LINEAR FIXTURE. VAPORTITE FIBERGLASS HOUSING W/ GASKETING FOR SEAMLESS SEAL. S 4" 6" 48" H2 X 3000K 2 120 COOPER SURE-LITES SERIES "AEL2" ARCHITECTURAL EMERGENCY EGRESS LIGHT WM 17.5" 8.25" H3 X 2751 3000K 26 120 LUMARK SERIES XTOR CROSSTOUR LED" ARCHITECTURAL AREA LIGHT WM 12" 17.125" 6" H4 X 12000 3000K 106 120 METALUX SERIES "SS LED" LED ROUND HIGH-BAY FIXTURE P 17" 16" P1 X 4095 3000K 87 120 EUREKA SERIES "CYCLE 72" DECORATIVE PENDANT, AIRCRAFT CABLE MOUNTING P 72" 18" P2 X 1392 3000K 18 120 TECH LIGHTING SERIES "HUTCH" LED PENDANT, 90 CRI P 13" 17" P3 X 737 3000K 9 120 LBL LIGHTING SERIES "ZEVO PENDANT" DECORATIVE PENDANT P 18" 8" P4 X 376 3000K 4 120 EUREKA SERIES "ANATOMY" DECORATIVE PENDANT P 13" 17" P5 3000K 0 120 CUSTOM SUN KING SUPPLIED CUSTOM PALETTE FIXTURE P 17" 16" P6 1 3000K 35 120 TECH LIGHTING SERIES "SOCO" SOCKET & CORD SET 6" 5" P7 X 1860 3000K 40 120 EUREKA SERIES "CYCLE 36" DECORATIVE PENDANT, AIRCRAFT CABLE MOUNTING P 36" 17" P8 X 1100 3000K 35 120 CONTECH LIGHTING SERIES "CY3" DECORATE LED CYLINDER FIXTURE 6" 5" S1 X 357 3000K 4 120 TECH LIGHTING SERIES "FETT WALL" DECORATIVE WALL SCONCE P 4" 12" TL 3000K 0 120 CONTECH LIGHTING SERIES "LT" TRACK LIGHTING CHANNEL, SINGLE CIRCUIT W/ CURRENT LIMITING POWER FEEDS WM 1.5" 1" TLF X 2700K 15 120 CONTECH LIGHTING SERIES "CTL8071" LED CYLINDER TRACK FIXTURE, MEDIUM, DIMMING, BLACK FINISH ●TRACK 3" 5" X X 5 5 120 COOPER SURE-LITES SERIES "LPXW"" FLAME RETARTDANT, POLYCARBONATE HOUSING, WHITE WITH RED LETTERS. 90-MINUTE BATTERY WITH SELF-DIAGNOSTIC MONITORING ●C 9" 13" 2.375" X1 X 125 5 120 TELESIS SERIES "TCL LED" THERMOPLASTIC HOUSING, BLACK FINISH, 2W LED HEADS, REMOTE HEAD CAPABILITY, 90-MINUTE BATTERY WITH SELF-DIAGNOSTIC MONITORING ●WM 5.375" 13" 5.75" NOTES: 1. SWITCH/STARTER LOCATED BY FORK TRUCK 2. 3. 4. MOTORS, STARTERS, DISCONNECTS & CONTROLS MARK MOTOR STARTER DISCONNECT MEANS CONTROL FEEDER SEE NOTENAMEPLATE CHARACTERISTICS NEMA SIZETYPE LOCATION FURNISHED BYTYPE LOCATION FURNISHED BY INTERLOCK WITH MOTOR NO. BY E.C. MANUAL AT STARTER INTEGRAL WITH EQUIPMENT FURNISHED BY SEE NOTE NUMBER OF CONDUCTORS WIRE SIZE GROUND SIZE CONDUIT SIZE HORSEPOWER (HP) LOAD (kVA) 120V-1PH 208V-1PH 208V-3PH 240V-1PH 240V-3PH 277V-1PH 480V-1PH 480V-3PH MANUAL MAGNETIC BUILT-IN MOTOR O/L 2-SPEED VFD SEE NOTE NEAR MOTOR MOTOR CONT CENTER EQUIP CONT PANEL ROOM NUMBER SEE NOTE DISC SWITCH MANUAL STARTER RECEPTACLE FEEDER SW OR BREAKER NEMA TYPE DISC SIZE FUSE SIZE NEAR MOTOR MOTOR CONT CENTER EQUIP CONT PANEL PANELBOARD SEE NOTEACCU-1 35.3 ● ● ● ● ● ●MC ●MC 3 1 6 2" ACCU-C1 2x 4 10.1 ● ● ● ● ● ●EC ●MC 3 8 10 1" ACCU-C2 3 3.5 ● ● ● ● ● ●EC ●MC 3 12 12 0.75" ACCU-F1 1.5 1.9 ● ● ● ● ● ●EC ●MC 3 12 12 0.75" ACCU-R 7.2 ● ● ● ● ● ●EC ●MC 3 10 10 0.75" AHU-1 5 2.7 ●● ● ● ●MC ●MC 3 8 10 1" CH-1 5 34.2 ● ● ● ● ●MC ●MC 3 1 6 1.25" EF-1 0.5 0.6 ●● ● ● ● ●MC ●EC 2 12 12 0.75" EF-2 1 1.1 ●● ● ● ● ●MC ●EC 2 12 12 0.75" EF-3 .16 0.5 ●● ● ● ● ●MC ●EC 2 12 12 0.75" EF-4 .25 0.7 ●● ● ●MC ● ●MC ●MC 2 12 12 0.75" EF-5 1 1.1 ●● ●MC ● ●MC ●EC 2 12 12 0.75" EF-6 .25 0.7 ●● ●1 MC ● ●MC ●EC 2 12 12 0.75" ELEV 10 11.2 ●●GC EC EC 3 8 10 1" EUH-1 10.1 ● ● ● ● ● ●MC ●MC 3 8 10 0.75" EUH-2 5 ● ● ● ● ● ●MC ●MC 3 12 12 0.75" EUH-3 5 ● ● ● ● ● ●MC ●MC 3 12 12 0.75" EWH-1 5 ● ● ● ● ● ●MC ●MC 3 12 12 0.75" GRAIN 2 2.4 ●EC EC 3 12 12 0.75" RCP-1 .20 0 ●● ●EC ● ●EC ●EC 2 12 12 0.75" RH-1,2 0.1 ●EC EC 2 12 12 0.75" RTU-1 19.5 ●● ● ● ●MC ●MC 3 6 10 0.75" RTU-2 64.1 ●● ● ● ●MC ●MC 3 4/0 3 2" No. Description Date 1 CONCRETE PAD BY E.C. 10" THICKNESS AND OPENINGS AS RECOMMENDED BY SUPPLIER OF TRANSFORMER. 1/2" DIA. REINFORCED 12"CC BOTH WAYS. 2 PEA GRAVEL UNDER CONCRETE PAD 12" MINIMUM TO EXTEND 2FT.BEYOND EDGE OF PAD (12" DEEP). 3 SEE PLAN AND SCHEDULES FOR NUMBER AND SIZE OF CONDUIT. 4 GROUND GRID, #1/0 BARE COPPER UNLESS OTHERWISE SHOWN. 5 5/8" X 10FT. GROUND RODS UNLESS OTHERWISE SHOWN. 6 5FT. #1/0 BARE COPPER GROUNDING PIGTAIL. 7 CONCRETE DUCT ENCASEMENT. 8 EXPOSED CONCRETE SURFACES TO HAVE RUBBED FINISH AND 3/4" CHAMFERED CORNERS. 9 PROTECTIVE BOLLARD WHERE SPECIFIED: CONSISTING OF 4" DIA. RIGID GALVANIZED STEEL PIPES FILLED WITH CONCRETE. SET IN 18" DIA. HOLE FILLED WITH TAMPED CONCRETE. 10 ALL PRIMARY AND SECONDARY UNDERGROUND CONDUITS TO HAVE LONG SWEEPING BENDS, PROPER ADAPTER FROM PVC TO RIGID METALLIC CONDUIT AND STUB 3" ABOVE CONCRETE PAD. 11 A MINIMUM OF 10FT. CLEAR AREA MUST BE MAINTAINED IN FRONT OF TRANSFORMER AND OTHER ELECTRIC DISTRIBUTION EQUIPMENT. 12 REFER TO SPEC. SECTION 26 27 13 FOR METERING REQUIREMENTS. COORDINATE METERING AND SERVICE ENTRANCE REQUIREMENTS WITH POWER COMPANY. 13 TRANSITION CABINET WITH METERING TRANSFORMERS. 14 TRENCH WITH DIAMOND PLATE COVER FOR SECONDARY CONDUCTOR IF PERMITED BY POWER COMPANY MY BE PROVIDED. DETAIL NOTES A COORDINATE EXACT CONCRETE PAD SIZE, OPENINGS AND OTHER REQUIREMENTS TO EXTEND EDGE OF CONCRETE 12" BEYOND EQUIPMENT. ALL SIDES OF EQUIPMENT PAD SHALL BE MAINTAINED RECTANGULAR WITH RUBBED FINISH AND CHAMFERED EDGE. REFER TO SPEC SECTION 26 27 13. COORDINATE EXACT ORIENTATION OF EQUIPMENT WITH POWER COMPANY PRIOR TO EXCAVATION AND PROVIDE ACCORDINGLY. B BOLLARDS NOT TO BE PROVIDED ON SIDES NEAR BUILDING. GENERAL DETAIL NOTES SECTION .30"...3"42"42"MIN.2 861 9 5 7 2 3 7 53 6 208Y/120V-3Ø-4W SECONDARY ELECTRICAL FEEDER(S) PROVIDED BY EC; REFER TO SINGLE-LINE DIAGRAM ON SHEET E002 2" EMPTY CONDUIT (WITH PULLWIRE) TO ELECTRIC METER; LOCATIONS AS INDICATED ON PLAN UNDERGROUND PRIMARY ELECTRIC SERVICE DUCTBANK BY CONTRACTOR, AND CONDUCTORS PROVIDED BY POWER COMPANY REFER TO SITE PLAN ON SHEET E301 FOR CONTINUATION. PAD MOUNTED TRANSFORMER BY POWER CO. 208Y/120V-3Ø-4W. SECONDARY. REFER TO SITE PLAN ON SHEET E301 FOR LOCATION. PLAN 8' 0" APPROX.36"TYP.APPROX 36" 5 14 11 6 10 12 13 4 10 5 9 1 11 1 3000 LB. CONCRETE. 2 4" I.D. DUCTS, SCHEDULE 40 PVC. 3 MIN. 3" SPACING BETWEEN CONDUITS AND MIN. 3" ENCASEMENT (TYPICAL). PROVIDE CONDUIT SPACERS 6'-0" O.C. 4 RED DYE, RED DUST OR YELLOW MARKER TAPE ON COMPACTED FILL. DETAIL NOTES FINISH GRADE ....... TAMPED BACKFILL 1'-6"1'-6"2'-3" COVER1'-6"4 1 2 33 3A BUILDING STEEL CONNECTION SHALL BE EXOTHERMIC WELD. CLEAN SURFACE TO BRIGHT METAL BEFORE CONNECTION AND RESTORE TO ORIGINAL FINISH AFTER MAKING CONNECTION. B BUILDING STEEL CONNECTION SHALL BE LOCATED ABOVE THE FINISH FLOOR. IN SOME CASES CONNECTIONS ARE TO BE MADE BELOW SLAB ON EXPOSED TUBE STEEL CASES. GENERAL DETAIL NOTES BUILDING STEEL CONNECTION FINISHED FLOOR LINE STEEL BUILDING COLUMN FOUNDATION #2/0 BARE CU GROUNDING CONDUCTOR #4/0 BARE CU GROUNDING GRID EXOTHERMIC WELD CONNECTION UNI-STRUT OR EQUAL CHANNEL BY DIV. 26 CONDUIT CLAMP CONDUIT SIZE AS REQUIRED SAFETY CABLE SHALL BE ATTACHED TO CHANNEL OR STRUCTURAL STEEL WIRE GUARD AND TEMPERED GLASS SAFETY LENS REFLECTOR BALLAST HOUSING POWER HOOK ASSEMBLY CONDUIT LENGTH AS REQUIRED JUNCTION BOX SHALL BE SUPPORTED FROM CHANNEL OR DIRECTLY FROM STRUCTURAL STEEL AS REQUIRED BY THE LOCATION OF THE LIGHT FIXTURE. CHANNEL SUPPORT AND THREADED ROD BY DIV. 26. SUPPORTED FROM STRUCTURAL STEEL A SEE DRAWINGS FOR MOUNTING HEIGHT AND FIXTURE TYPE. GENERAL DETAIL NOTES SUPPRESSION SYSTEM MICRO SWITCHES 120 V DEDICATED CONTROL CIRCUIT CONTROL RELAY, 8 POLE, 120 VAC COIL MOUNTED IN NEMA 1 ENCLOSURE. SQUARE D #8501X080V02 OR APPROVED EQUAL GAS VALVE SHUNT TRIP CIRCUIT BREAKER SUPPLY AIR FAN INTERLOCK EXHAUST FAN INTERLOCK FAP SIGNAL SPARE SPARE 120V MECHANICALLY HELD CONTACTOR 100A-3P FUSED DISC SW 100A-3P 100AF TO 208V/3Ø SOURCE TO 120V SOURCE AUXILARY RELAY TO FA 24VDC OPT. AUX. CONTACT (SET) L NC O C O R NL C C L2L1L2L1 L3 FUSED DISC SW 30A-2P 20AF T2T1 T3 ELEVATOR PUMP MOTOR ELEVATOR CONTROL POWER PACK (PP)N H OCCUPANCY SENSOR OCCUPANCY SENSOR (AS REQ'D.) H LED DRIVER(S) LV N A B C D E F LV LOW VOLTAGE AS REQUIRED BY THE MANUFACTURER H HOT WIRE LINE VOLTAGE N NEUTRAL WIRE LINE VOLTAGE 120V INTENT OF DETAIL IS FOR AUTO-ON/OFF OPERATION OF THE NORMAL-POWER LUMINAIRES IN THE CORRIDOR/ROOM. THE OCCUPANCY SIGNAL WILL BE PROVIDED BY THE INSTALLED SENSOR(S). DETAIL IS SCHEMATIC IN NATURE. REFER TO MANUFACTURES SPECIFIC WIRING DIAGRAMS FOR EXACT WIRING INFORMATION. EQUIPMENT SUPPLIER/ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY ADDITIONAL COST FOR REVISIONS REQUIRED FROM DETAIL DUE TO A DIFFERENT SYSTEM SELECTION. MOUNT POWER PACK ABOVE ACCESSIBLE CEILING. ALL EQUIPMENT SHALL BE MOUNTED IN AN ENCLOSURE PER THE MANUFACTURERS DIRECTIONS. CONTRACTOR SHALL COORDINATE WITH MANUFACTURER FOR EXACT NUMBER OF POWER PACKS, OCCUPANCY SENSORS (FOR COMPLETE COVERAGE OF THE CORRIDOR) AND ANY ADDITIONAL COMPONENTS FOR A COMPLETE AND OPERABLE SYSTEM. COORDINATE EXACT COMPONENT MOUNTING LOCATIONS FOR PROPER CLEARANCE AND ACCESSIBILITY PRIOR TO ROUGH-IN. GENERAL NOTES 1 20A 120V. CONTROL CCT. 2 PHOTOCELL INTERMATIC *K4136M (120/277V). 3 CONTACTOR C1A - MECHANICALLY HELD 10 POLE LIGHTING CONTACTOR. SQUARE D, LXG-1000R6 WITH ONE H.O.A. SWITCH AND 120V. COIL. WIRE IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. 4 CONTACTOR C1A, TIMECLOCK AND H.O.A. SWITCH TO BE MOUNTED IN ONE NEMA 1 LOCKABLE ENCLOSURE WITH HINGED COVER. 5 TIMECLOCK: TORK DZS400BP (120V). ASTRONOMIC 2 DAY 2 CIRCUIT WITH POWER BACKUP. DETAIL NOTES CCT. NO.FIXTURES CONTROLLED CONTACTOR C1A PHOTOCELL ON TIMER OFF *INDICATES SPARE FOR FUTURE USE T A O H C PC T * * * * * * * 3 1 2 4 5 A STRUCTURAL DETAIL SHOWN IS REPRESENTATIVE ONLY. REFER TO ARCHITECTURAL CONDITIONS ON THIS PROJECT. GENERAL DETAIL NOTES ..3'-0"12"3/4" RGS CONDUIT 1-1/2" TO 3/4" REDUCING FITTING EPDM RUBBER CAP WITH STAINLESS STEEL CLAMP SPUN ALUMINUM BASE FLANGE ROOFING/FLASHING 3-1/2" X 3-1/2" X 1/4" L (TYP. 2) 1-1/2" U-BOLT (TYP. 2) 1-1/2" TO 3/4" REDUCING FITTING 4" X 4" J-BOX WITH BLANK COVER 3/4" EMT BOX COMPRESSION CONNECTION 3/4" EMT CONDUIT 3/4" RGS NIPPLE, NUT WASHER AND COMPRESSION CONNECTOR www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 11:25:23 AME004 ELECTRICAL DETAILS Sun King Spirits JB KAS 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017ELECTRICAL DISTRIBUTION CENTER & TRANSFORMER PAD1 UNDERGROUND DUCTS2STRUCTURAL GROUNDING3 TYPE II HIGH BAY LUMINAIRE MOUNTING5 KITCHEN HOOD RELAY4 ELEVATOR WIRING SCHEMATIC7 OCCUPANCY SENSING - SINGLE CIRCUIT8 EXTERIOR LIGHTING CONTROLS9 PHOTOCELL MOUNTING6 (USED IN FOOD 1, FOOD 2 & FOOD 3) No. Description Date 3 DM L DM DM DM DMDM OS OS OS OS OS OS OS A B C C.4 D E.7 11.2 1.4 2 2.4 3 4 5 6 Mill Room 121 Water 110 Food 1 120 JNTR CLST 119 Distillery 104 Freezer 109 Cooler 108 Cooler 107 Food 3 114 Hall 118 RR 116 RR 117 Hall 106 STAIR 112 STORAGE 105 Bar 102 Retail 122 Bar 103 Elec. 111 Food 2 115 Dining 101 Kitchen 113 VESTIBULE 100 C1 B1 B1 B1 D1 D1 D1 D1 B1 B1 P3 P3 P3 P3 P3 P3 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 H1 H1 H2 H2 A1 A1 A1 A1 A1 A1 B3 B3 B3B3 B3B3 B3 TL TL TL TL TL TL TL TL TL TL TL TL TL TL C1 P2 P1 B2 H2 A2 A2 A2 D2 D2 D2 D2 D2 D2 D2 D2 D2 1 2 3 4 A2 A2 A2 A2A2A2 A2 A2 A2 A2 A2 A2 A2 A2 P1 B2 P4 P5 P5 B1 B1 B1 B1 B1 B1 B1B1B1 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2B2 H3 5 5 5 A1 6 7 B1 D1 G1 B3 B3 B1 B1 S1S1 S1 S1 C2 C2 P2 P2 P2 X C3 C3 B3 8 1L1 - 4 1L1 - 5 1L1 - 7 1L1 - 6 1L2 - 1 1L3 - 1 1L4 - 1 C1 1L1 - 14 1L1 - 11 1L1 - 12 1L1 - 9 1L1 - 3 1L1 - 9 1L1 - 9 1L1 - 15 1L1 - 16 1L2 1L4 1L3 MDP 1L1 P6 P6 P6 P6 P6 P6 P6 P6 X1 X1 X X X X X XX X X1 X1 X1 P8 P8 P8 P8 P8 P8 P8 P8 P6 TL TLTL TL1L1 - 20 TLF (TYP) TLF (TYP) TLF (TYP)TLF (TYP) TLF (TYP) TLF (TYP) TLF (TYP) TLF (TYP) TLF (TYP) TLF (TYP) TLF (TYP) TLF (TYP) TLF (TYP) TLF (TYP) TLF (TYP) 1L1 - 18 1L1 - 8 1L1 - 9 1L1 - 10 1L1 - 13 1L1 - 19 X1 9 9 9 99 www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 11:25:33 AME201 FIRST FLOOR LIGHTING PLAN Sun King Spirits JB KAS 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 SCALE: 1/8" = 1'-0" FIRST FLOOR LIGHTING PLAN1 1 THIS WINDOW IS TO BE OUTLINED WITH LED TAPE LIGHTING. REFER TO ARCHITECTURAL DRAWINGS FOR DETAIL ON LED TAPE INSTALLATION. 2 FIXTURE IS MOUNTED ON TOP OF CANOPY. COORDINATE AIMING WITH ARCHITECT AND/OR LIGHTING REPRESENTATIVE UPON COMPLETION OF INSTALLATION. 3 LED TAPE LIGHT ALONG PERIMETER. REFER TO ARCHITECTURAL DRAWINGS FOR DETAIL ON LED TAPE INSTALLATION. 4 REFER TO 2ND FLOOR PLANS, SHEET E202, FOR LIGHTING IN THIS SPACE/ROOM. 5 LIGHTING INTEGRAL TO AND PROVIDED BY COOLER/FREEZER SUPPLIER. E.C. IS TO WIRE FIXTURES AND SWITCHING UPON INSTALLATION OF THE COOLER/FREEZER. 6 THIS ROOM IS CLASSIFIED AS A N.E.C. CLASS II, DIVISION 1 INSTALLATION. ALL WIRING METHODS AND EQUIPMENT IN THIS ROOM IS TO MEET APPLICABLE SECTIONS OF N.E.C. 502. 7 LIGHT SWITCH FOR MILL ROOM 121. 8 ELEVATOR CAB LIGHTING SWITCH/DISCONNECT. PROVIDE SWITCH LOCK-OUT MECHANISM. 9 EXTERIOR BUILDING LIGHTING TO BE CONTROLLED BY TIME CLOCK/PHOTO-CELL CONTROL. REFER TO DETAIL 6\E004 & 9\E004 FOR DETAILS. PLAN NOTES A ALL EMERGENCY AND EXIT FIXTURES ARE TO BE CIRCUITED TO 1L1-1. B EMERGENCY LIGHTING IS TO BE WIRED AHEAD OF ALL LOCAL CONTROLS (WALL SWITCHES, OCCUPANCY SENSORS, ETC) SUCH THAT FIXTURES OPERATE WITH THE NORMAL LIGHTING. CIRCUIT THE LOSS-OF-POWER SENSE WIRE AHEAD OF ALL LOCAL CONTROLS, C VERIFY EXACT LOCATION OF ALL LIGHTING FIXTURES WITH REFLECTED CEILING PLAN AND/OR ARCHITECT PRIOR TO ROUGH-IN. D COORDINATE LOCATIONS OF LIGHTING FIXTUES WITH MECHANICAL DUCTS AND SPRINKLER PIPES AND HEADS BEFORE ROUGH-IN TO PREVENT CONFLICTS. E COORDINATE OCCUPANCY SENSOR AIMING AND PLACEMENT WITH MANUFACTURER OR SUPPLIER PRIOR TO INSTALLATION. F OCCUPANCY SENSOR MANUFACTURERS WITH DIFFERENT COVERAGE PATTERNS OR RECOMMENDED AIMING PRACTICES FROM SPECIFIED MANUFACTURER SHALL SUBMIT 1/8 INCH SCALE FLOOR PLANS SHOWING PROPOSED LAYOUT WITH DEVICES CLEARLY IDENTIFIED DURING THE SHOP DRAWING REVIEW PHASE. SHOP DRAWINGS MISSING THIS INFORMATION WILL BE REJECTED. REQUEST AUTOCAD FLOOR PLANS WELL IN ADVANCE OF SHOP DRAWING SUBMITTAL TO ENSURE ON TIME DELIVERY. G WIRE ALL OCCUPANCY SENSORS IN SAME AREA IN PARALLEL (NORMAL POWER LIGHTING) FOR COMMON ZONE CONTROL. GENERAL NOTES No. Description Date J J 3DM DM DM DM DM DM DM DM DM DM OS OS OS OS OS OS OS OS A B C C.4 D E.7 11.2 1.4 2 2.4 3 4 5 6 RR 212 PIZZA OVEN 216 HALL 206 BOILER ROOM 207 RR 204 RR 205 STAFF BREAK 211 CATERING PREP 214 SUPPORT 215 JAN 208 OFFICE 210 BAR 201 DECK 202 PRIVATE FUNCTION 203 DINING 200 STAIR 213 Hall 209 C1 TLTLTLTL TL 1 2 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 P2 PENDANTS ARE MOUNTED @ 23'-6" AFF B2 B2 B2 B2 B2 B2 B2 A1 A1 A1 A1A1 A1 A1 A1 A1 A2 A2 A1 A1 A1 A1 A1A1 B2 B2 B2 B2B2 B2 B1 S1S1 B1 S1S1 TL TL TL TLTL B2 B2 B2 B2 B3 B3 B3 C2 C2 P2 P2 P2 P2 P2 P2 P2 P2 X P7 TL H3 H3 1L1 - 17 2L1 1L1 - 5 2L1 - 8 2L1 - 7 2L1 - 9 2L1 - 4 2L1 - 3 2L1 - 5 2L1 - 2 1L1 - 3 2L1 - 12 H2 H1 P6P6 P6P6 P6 P6 P8 P8 P8 P8 2L1 - 10 TL TLF (TYP) TLF (TYP) TLF (TYP) TLF (TYP) TLF (TYP) TLF (TYP) TLF (TYP) TLF (TYP) TLF (TYP) TLF (TYP) TLF (TYP)TLF (TYP) 2L1 - 14 1L1 - 53 2L1 - 132L1 - 11 X X1 X1 X1 X1 X 4 4 www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 11:25:43 AME202 SECOND FLOOR LIGHTING PLAN Sun King Spirits JB KAS 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 SCALE: 1/8" = 1'-0" SECOND FLOOR LIGHTING PLAN1 1 120V BRANCH CIRCUIT FOR SIGNAGE. 2 120V BRANCH CIRCUIT FOR FUTURE PERGOLA LIGHTING. 3 PROVIDE EM INVERTER FOR STAIR TRACK LIGHTING. LOCATE ABOVE ACCESSIBLE CEILING NEAR STAIRS. 4 EXTERIOR BUILDING LIGHTING TO BE CONTROLLED BY TIME CLOCK/PHOTO-CELL CONTROL. REFER TO DETAIL 6\E004 & 9\E004 FOR DETAILS. PLAN NOTES GENERAL NOTES A ALL EMERGENCY AND EXIT FIXTURES ARE TO BE CIRCUITED TO 2L1-1. B EMERGENCY LIGHTING IS TO BE WIRED AHEAD OF ALL LOCAL CONTROLS (WALL SWITCHES, OCCUPANCY SENSORS, ETC) SUCH THAT FIXTURES OPERATE WITH THE NORMAL LIGHTING. CIRCUIT THE LOSS-OF-POWER SENSE WIRE AHEAD OF ALL LOCAL CONTROLS, C VERIFY EXACT LOCATION OF ALL LIGHTING FIXTURES WITH REFLECTED CEILING PLAN AND/OR ARCHITECT PRIOR TO ROUGH-IN. D COORDINATE LOCATIONS OF LIGHTING FIXTUES WITH MECHANICAL DUCTS AND SPRINKLER PIPES AND HEADS BEFORE ROUGH-IN TO PREVENT CONFLICTS. E COORDINATE OCCUPANCY SENSOR AIMING AND PLACEMENT WITH MANUFACTURER OR SUPPLIER PRIOR TO INSTALLATION. F OCCUPANCY SENSOR MANUFACTURERS WITH DIFFERENT COVERAGE PATTERNS OR RECOMMENDED AIMING PRACTICES FROM SPECIFIED MANUFACTURER SHALL SUBMIT 1/8 INCH SCALE FLOOR PLANS SHOWING PROPOSED LAYOUT WITH DEVICES CLEARLY IDENTIFIED DURING THE SHOP DRAWING REVIEW PHASE. SHOP DRAWINGS MISSING THIS INFORMATION WILL BE REJECTED. REQUEST AUTOCAD FLOOR PLANS WELL IN ADVANCE OF SHOP DRAWING SUBMITTAL TO ENSURE ON TIME DELIVERY. G WIRE ALL OCCUPANCY SENSORS IN SAME AREA IN PARALLEL (NORMAL POWER LIGHTING) FOR COMMON ZONE CONTROL. No. Description Date WP/GFWP/GF WP/GF WP/GF WP/GF WP/GF GF GF GF WP/GF GF GF GF GF GF GF J J J J J J WP/GF WP/GF J J GF GF GFGF GF GF GF GF GF GFGF H V V FS GFGFGFGFGFGFF 30 F F 30 F 15 F 30 F 15 F 30 F 30 15 15 F F F K FACP TV 102" MH TV102" MH TV102" MH TV102" MH 15 15 15 GF F 30 HGFGFTV 90" MH TV 90" MHGF A B C C.4 D E.7 11.2 1.4 2 2.4 3 4 5 6 Mill Room 121 Food 1 120 JNTR CLST 119 Distillery 104 Freezer 109 Cooler 108 Cooler 107 Food 3 114 Hall 118 RR 116 RR 117 Hall 106 STAIR 112 STORAGE 105 Bar 102 Retail 122 Bar 103 Food 2 115 Dining 101 Kitchen 113 VESTIBULE 100 Info 54 MDP METER SERVICE X'FMR 8 9 9 9 4 5 6 7 3 3 3 1L1 10 11 11 1 1 1 14 1L2 1L4 1L3 15 1 EUH-1 EWH-1 1DP 1DP - 13 1DP - 10 1L1 - 30 1L1 - 36 1L4 - 3 1L4 - 4 1L4 - 2 1L3 - 31L3 - 4 1L2 - 4 1L2 - 2 1L2 - 3 1L1 - 47,49,51 1L1 - 33 1DP - 16 1L1 - 32 1DP - 15 1L1 - 34 1L1 - 35,37,39 1L1 - 41,43,45 GRAIN 1DP - 14 1L1 - 2 1L1 - 38 1L1 - 40 1L1 - 42 1L1 - 46 1L1 - 44 1L1 - 48 1L1 - 50 1L1 - 52 1L1 - 54 1L1 - 55 E301 2 1L1 - 561L1 - 581L1 - 661L1 - 601L1 - 621L1 - 642 2 RH-1 RH-2 1L1 - 63 1L1 - 63 1L1 - 72 1L1 - 70 +46" +46" +46" WP 16 1L1 - 22 E301 3 1L1 - 75 21 WP A 6 A 6 A 6A.12 Water 110 Elec. 111 1L1 1DP MDP EUH-3 EUH-2 1L1 - 21 1L1 - 28 1L1 - 251L1 - 29 1L1 - 23 1L1 - 27 1DP - 12 1L1 - 31 1DP - 11 13 1L1 - 61 RCP-1 ROM1 ROP-1,2 1L1 - 59 2 2.4 C.3 2 2.422.4 Bar 103 1L1 - 65 12 TYP. 1L1 - 68 1L1 - 53 1L1 - 531L1 - 68 17 18 17 192019 1L1 - 53 1L1 - 67 1L1 - 711L1 - 73 1L1 - 74 1L1 - 691L1 - 69 1 1 121 www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 11:25:55 AME301 FIRST FLOOR POWER & SYSTEMS PLAN Sun King Spirits JB KAS 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 1 POINT-OF-SALE STATION. PROVIDE 120V BRANCH CIRCUIT AND DATA OUTLET(S) FOR EACH POS STATION. COORDINATE QUANTITY AND ACTUAL LOCATIONS WITH ARCHITECT PRIOR TO ROUGH-IN. 2 120V BRANCH CIRCUITS FOR SINK CONTROLS AND INTEGRATED HAND DRYER. COORDINATE LOCATIONS WITH ARCHITECT PRIOR TO ROUGH-IN. 3 120V BRANCH CIRCUIT FOR EXHAUST HOOD. 4 208V/3Ø/30A DISCONNECT FOR AIR COMPRESSOR. 5 FERMENTER CONTROL PANEL. PROVIDE 120V BRANCH CIRCUIT. COORDINATE ACTUAL LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. 6 DISTILLER CONTROL PANEL. PROVIDE 30A, 208V, 3Ø CIRCUIT TO INTEGRAL FUSED DISCONNECT. 7 208V/3Ø/30A DISCONNECT FOR FORK TRUCK BATTERY CHARGER. BATTERY CHARGER TO BE LOCATED ABOVE FORK TRUCK PARKING, SUSPENDED FROM STRUCTURE ABOVE. 8 208V/30A BRANCH CIRCUIT FOR STEP-IN COOLER. 9 120V BRANCH CIRCUIT FOR COOLER/FREEZER. E.C. IS RESPONSIBLE FOR ALL WIRING ASSOCIATED W/ COOLERS & FREEZERS (I.E. LTG, EVAPORATORS, DISCONNECTS, HEAT TAPE, CONTROL WIRING, ETC) 10 DISCONNECT FOR BRIDGE CRANE. COORDINATE ACTUAL LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. 11 120V/20A BRANCH CIRCUIT FOR BEER LINE CHILLER. 12 MOUNT 6" UNDER BAR SURFACE IN KNEE SPACE ON CUSTOMER SIDE. 13 120V/20A BRANCH CIRCUIT FOR RO SYSTEM CONTROL PANEL. 14 208V/3Ø/30A FUSIBLE SAFETY SWITCH FOR MILLING MACHINE. 15 THIS ROOM IS CLASSIFIED AS A N.E.C. CLASS II, DIVISION 1 INSTALLATION. ALL WIRING METHODS AND EQUIPMENT IN THIS ROOM IS TO MEET APPLICABLE SECTIONS OF N.E.C. 502. 16 ALL DEVICES IN THIS ROOM ARE TO HAVE WEATHERPROOF (WP) COVERS AND/OR BE NEMA 3R RATED. 17 BACK BAR COOLER. 18 WINE COOLER DISPENSER. 19 BOTTLE COOLER. 20 UNDERCOUNTER SINK W/ GLASSWARE SCRUBBER. 21 SODA DISPENSER. PLAN NOTES A INSTALL A 4"X4" DEEP BACKBOX W/ A SINGLE GANG MUDRING NEXT TO EACH TV RECEPTACLE FOR INSTALLATION OF TV FEED. GENERAL NOTES SCALE: 1/8" = 1'-0" FIRST FLOOR POWER & SYSTEMS PLAN1 SCALE: 1/4" = 1'-0" ENLARGED PLAN - 110 & 1112 SCALE: 1/4" = 1'-0" ENLARGED PLAN - BAR 1033 No. Description Date WP/GF WP/GF WP/GF GF GF GF GF GF GF GF GF GF GF H J GF WP/GF WP/GF FS VGFGFGF GFGFF 30 15 15 F 15 F 30 F 30 FF 30 F 30 F TV102" MHTV102" MH TV 102" MH TV 90" MH 15 15S HSAMCAMCAMCAMC TV 102" MH GF A B C C.4 D E.7 11.2 1.4 2 2.4 3 4 5 6 RR 212 PIZZA OVEN 216 HALL 206 BOILER ROOM 207RR 204 RR 205 STAFF BREAK 211 CATERING PREP 214 SUPPORT 215 JAN 208 OFFICE 210 BAR 201 DECK 202 PRIVATE FUNCTION 203 DINING 200 STAIR 213 Hall 209 2L1 2 RTU-1 RTU-2 CH-1 AHU-1 1 3 ACCU-C1 ACCU-C2 ACCU-F1 ELEV 2L1 - 22 2L1 - 35 2L1 - 32 2L1 - 33 2L1 - 34 2L1 - 28 2L1 - 19 2L1 - 262L1 - 24 2L1 - 27 2L1 - 23 2L1 - 21 2L1 - 37 2L1 2L1 - 39 2L1 - 36 2L1 - 29 ACCU-1 EF-6 1DP - 2 1DP - 3 1DP - 5 1DP - 6 1DP - 7 1DP - 8 1DP - 9 2L1 - 55 2L1 - 25 1DP - 4 1L1 - 575 1DP - 1 2 22L1 - 382L1 - 422L1 - 402L1 - 412L1 - 432L1 - 31 WP E302 2 2L1 - 30 3 3.7 C.3 33 3.7 C.3 A.11 BAR 201 2L1 - 44 2L1 - 30 2L1 - 31 716 4 TYP. www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 11:26:04 AME302 SECOND FLOOR POWER & SYSTEMS PLAN Sun King Spirits JB KAS 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 1 POINT-OF-SALE STATION. PROVIDE 120V BRANCH CIRCUIT AND DATA OUTLET(S) FOR EACH POS STATION. COORDINATE QUANTITY AND ACTUAL LOCATIONS WITH ARCHITECT PRIOR TO ROUGH-IN. 2 120V BRANCH CIRCUIT FOR SINK CONTROLS AND INTEGRATED HAND DRYER. COORDINATE LOCATIONS WITH ARCHITECT PRIOR TO ROUGH-IN. 3 120V BRANCH CIRCUIT FOR PIZZA OVEN. 4 MOUNT 6" UNDER BAR SURFACE IN KNEE SPACE ON CUSTOMER SIDE. 5 120V BRANCH CIRCUIT FOR DRY-PIPE SYSTEM AIR COMPRESSOR. 6 SODA DISPENSER 7 BOTTLE COOLER. PLAN NOTES A INSTALL A 4"X4" DEEP BACKBOX W/ A SINGLE GANG MUDRING NEXT TO EACH TV RECEPTACLE FOR INSTALLATION OF TV FEED. GENERAL NOTES SCALE: 1/8" = 1'-0" SECOND FLOOR POWER & SYSTEMS PLAN1 SCALE: 1/4" = 1'-0" ENLARGED PLAN - BAR 2012 No. Description Date WP/GF A B C C.4 D E.7 11.2 1.4 2 2.4 3 4 5 6 RH-1 EF-5 EF-1 EF-4 EF-2 EF-3 2L1 - 53 2L1 - 57 2L1 - 47 2L1 - 49 2L1 - 45 2L1 - 51 2L1 - 46 www.DELVdesign.com Scale Date Drawn By Checked By Project Number DELV Design 212 W 10th St, STE F125 Indianapolis, IN 46202 (317) 296-7400 www.DELVdesign.com ARCHITECT JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW, STE 116 INDIANAPOLIS, IN 46240 (317) 617-4270 STRUCTURAL HEAPY ENGINEERING 3850 PRIORITY WAY SUITE #204 INDIANAPOLIS, IN 46240 (317) 571-8795 MEP ENGINEERING CIVIL & ENVIRONMENTAL CONSULTANTS 530 E. OHIO STREET, SUITE G INDIANAPOLIS, IN 46204 (317) 655-7778 CIVIL ENGINEERING F.A. WILHELM CONSTRUCTION.CO 3914 PROSPECT ST. INDIANAPOLIS, IN 46203 (317) 359-5411 DESIGN BUILD CONTRACTOR 3/30/2017 11:26:10 AME303 ROOF POWER PLAN Sun King Spirits JB Author 16-048 CONSTRUCTION DOCUMENTS 30 MARCH 2017 SCALE: 1/8" = 1'-0" ROOF POWER PLAN1 No. Description Date