HomeMy WebLinkAboutPLUMBING DRAWINGSGENERAL SYMBOLS:PLAN NOTEPIPE ELBOW UP (RISER)PIPE ELBOW DOWNUNIONPIPE TEE DOWNPIPE TURN 90°CAP OR PLUGREDUCER, CONCENTRICREDUCER, ECCENTRICFLANGESLINE BREAKBALL VALVEVALVES & FITTINGS:GLOBE VALVEGATE VALVEBUTTERFLY VALVECHECK VALVEREDUCED PRESSURE BACKFLOW PREVENTERGAUGEPIPE SLOPES IN DIRECTION OF ARROWDOMESTIC HOT WATER RETURNDOMESTIC COLD WATERDOMESTIC HOT WATERSANITARY VENTREVISIONTHERMOMETERPIPING DESIGNATIONS:NEW PIPING1DETAIL BUBBLEAM-5011DOMESTIC HOT WATER 140°F RETURNDOMESTIC HOT WATER 140°F140°F140°FSTORM PIPINGSTINDIRECT DRAINDLAWN SPRINKLERLSMETERFLOOR DRAINFDVALVE IN VERTICAL PIPECONTROL VALVEINDICATED FLOW DIRECTIONMWASTE PIPINGWPLUMBING ABBREVIATIONS:AFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADEAHU AIR HANDLING UNITAD ACCESS DOORAV ACID VENTAW ACID WASTEBDD BACK DRAFT DAMPERBHP BRAKE HORSEPOWERBLDG BUILDINGBOD BOTTOM OF DUCTBOP BOTTOM OF PIPEBOS BOTTOM OF STEELBTU BRITISH THERMAL UNITCO CLEANOUTCW DOMESTIC COLD WATERD CONDENSATE/DRAINDB DRY BULBDCV DOUBLE CHECK VALVEDIA DIAMETERDN DOWNDWH DOMESTIC WATER HEATERFD FLOOR DRAINEL ELEVATIONEXIST EXISTINGFCO FLOOR CLEANOUTFLA FULL LOAD AMPSHB HOSE BIBBHKSP HOUSEKEEPINGHW DOMESTIC HOT WATERIE INVERT ELEVATIONJS JANITOR SINKL / LAV LAVATORYMB MOP BASINNC NORMALLY CLOSEDNO NORMALLY OPENPIV POST INDICATING VALVEPSIA POUNDS PER SQUARE INCH ABSOLUTEPSIG POUNDS PER SQUARE INCH GAUGERO REVERSE OSMOSISRPBP REDUCED PRESSURE BACKFLOW PREVENTERSI SEDIMENT INTERCEPTORSK SINKSS STAINLESS STEELST STORM WATERTD TRENCH DRAINV SANITARY VENTVTR VENT THROUGH ROOFWC WATER CLOSETWH WALL HYDRANT1.VERIFY CONDITIONS IN THE FIELD PRIOR TO BUILDING AND BEFORE BEGINNINGWORK.2.REVIEW THE WORK OF OTHER TRADES, COORDINATE AND PLAN WORK WITH THEOTHER TRADES AND OWNER. ADJUST AS A RESULT OF COORDINATION.3.STORE EQUIPMENT AND COMPONENTS IN A CLEAN, DRY LOCATION UNTIL READYFOR INSTALLATION. PROTECT FROM WEATHER, DIRT, WATER, AND CONSTRUCTIONDEBRIS, ETC. AT ALL TIMES. ANY DAMAGED EQUIPMENT OR COMPONENTS SHALLBE RESTORED AS NEW OR REPLACED.4.PATCH WALLS, FLOORS, CEILINGS, COLUMNS, ROOF PENETRATIONS, ETC. WHEREITEMS ARE REMOVED TO MATCH ADJACENT SURFACES.5.DRAWINGS SHOW THE INTENDED ARRANGEMENT AND ROUTING OF ALL PIPING,EQUIPMENT, AND APPURTENANCES. THEY SHALL BE FOLLOWED AS CLOSELY ASACTUAL BUILDING CONSTRUCTION AND WORK OF OTHER TRADES WILL PERMIT.6.CLEAN ALL EQUIPMENT TO PRESENT A "LIKE NEW" CONDITION AT PROJECTCOMPLETION.7.OFFSET PIPING AROUND ELECTRICAL PANELS TO PROVIDE CLEARANCES ASREQUIRED BY THE NATIONAL ELECTRICAL CODE.GENERAL NOTES:W WASTEUS UTILITY SINKOFD/ORD OVER FLOW DRAIN/OVERFLOW ROOF DRAING / NG GAS / NATURAL GASCFH CUBIC FEET PER HOURTMV THERMOSTATIC MIXING VALVEWCO WALL CLEANOUTUR URINALSAN SANITARYRD ROOF DRAINOI OIL INTERCEPTORFS FLOOR SINKPHW PROCESS HOT WATERDIVISION 22 - PLUMBING1. ALL MATERIAL, EQUIPMENT, AND INSTALLATION PRACTICES SHALL COMPLY WITH STATE AND LOCAL BUILDING AND BOARD OF HEALTH,NFPA, AND OSHA CODES AND UTILITY REQUIREMENTS.2. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED BY THE AUTHORITIES HAVING JURISDICTION.3. ALL MATERIAL AND EQUIPMENT SHALL BE NEW.4. THIS CONTRACTOR SHALL PAY FOR ALL CUTTING AND PATCHING REQUIRED FOR THE INSTALLATION OF THEIR WORK.5. SUBMIT SHOP DRAWINGS ON MATERIALS AND EQUIPMENT PROPOSED TO BE FURNISHED ON THE PROJECT FOR REVIEW AND APPROVALBY THE ENGINEER AND OWNER. SUBMIT IN TIMELY FASHION ALLOWING TWO WEEKS FOR CHECKING AND PROCESSING. THECONTRACTOR SHALL ASSUME RESPONSIBILITY FOR DELAYS INCURRED DUE TO REJECTED ITEMS. THE CONTRACTOR SHALL RESUBMIT ONITEMS REJECTED UNTIL APPROVAL IS GIVEN. PROVIDE A COVER SHEET WITH EACH SUBMITTAL WITH ROOM FOR THE CONTRACTOR'SREVIEW STAMP AND THE ENGINEER'S REVIEW STAMP. INCLUDE PROJECT NAME, PROJECT LOCATION, NAME OF CONTRACTOR, SUPPLIER,OWNER, ARCHITECT, AND ENGINEER, AND ARCHITECTS/ENGINEERS COMMISSION NUMBER(S).6. WARRANTY: FURNISH IN WRITING A ONE (1) YEAR GUARANTEE FROM THE DATE OF SUBSTANTIAL COMPLETION THAT MATERIALS ANDWORK ARE FREE FROM DEFECTS AND FAULTY WORKMANSHIP, AND THAT DEFECTIVE MATERIALS OR WORK WILL BE REPAIRED ORREPLACED WITHOUT ADDITIONAL COST TO THE OWNER. PROVIDE CERTIFICATES OF WARRANTY FOR EQUIPMENT HAVING SPECIALWARRANTIES AND WHERE WARRANTIES EXCEED THE ONE (1) YEAR TIME PERIOD.7. LOCATION OF ALL PIPING, FIXTURES AND EQUIPMENT ARE APPROXIMATE ONLY AND MAY BE CHANGED TO MEETARCHITECTURAL AND STRUCTURAL FIELD CONDITIONS AS REQUIRED AND AS APPROVED BY THE ARCHITECT/ENGINEER. VERIFY ALLDIMENSIONS FROM ARCHITECTURAL PLANS AND WITH FIELD MEASUREMENTS.8. UNIONS AND VALVES SHALL BE PROVIDED AT PIPING CONNECTIONS TO ALL EQUIPMENT.9. ALL CONNECTIONS BETWEEN DISSIMILAR PIPE MATERIALS SHALL BE MADE WITH "EPCO" FITTINGS TO PREVENT GALVANIC ACTION.10. INSTALL PIPING TO ALLOW SERVICING OF EQUIPMENT WITHOUT AFFECTING PIPING SYSTEMS.11. PROVIDE CHROME PLATED ESCUTCHEONS AT ALL EXPOSED PIPING PENETRATIONS OF FLOORS, CEILINGS, AND WALLS.12. HANGERS AND SUPPORTS: PROVIDE PIPE SUPPORT BY INDIVIDUAL CLEVIS OR PEAR TYPE HANGER. TRAPEZE HANGERS MAY BE USEDTO SUPPORT GROUPED PIPING, SPACING AS REQUIRED FOR THE SMALLEST PIPE SIZE OR MINIMUM SPACING REQUIRED. SIZE HANGERSTO ALLOW FOR PIPE INSULATION WITHOUT COMPRESSING OR PENETRATING INSULATION. INSTALL HANGERS PER MSS SP-69 ANDSP-89 RECOMMENDATIONS. INSTALL SUPPORTS WITH MAXIMUM SPACING COMPLYING WITH MSS SP-69 AND PER THE FOLLOWING:a. STEEL TUBEPIPE DIAMETERSPACINGSUPPORT ROD DIAMETER1/4" THROUGH 1" 8 FT. HORIZ. 1/4"ALL SIZES 10 FT. VERTb. STEEL AND DUCTILE IRON PIPEPIPE DIAMETERSPACINGSUPPORT ROD DIAMETER1/2" THROUGH 1" 7 FT. HORIZ. 1/4"1 1/4" 7 FT. HORIZ 3/8"1 1/2" 8 FT. HORIZ. 3/8"2" 10 FT. HORI 3/8"2 1/2" 11 FT. HORI 1/2"3" 12 FT. HORI 1/2"4" THROUGH 5" 12 FT. HORIZ. 5/8"6" 12 FT. HORIZ. 3/4"8" THROUGH 12" 12 FT. HORIZ. 7/8"ALL SIZES 15 FT. VERT.c. COPPER PIPEPIPE DIAMETERSPACINGSUPPORT ROD DIAMETER1/2" THROUGH 1" THROUGH 1 1/4" 6 FT. HORIZ. 3/8"1 1/2" THROUGH 2" 8 FT. HORIZ. 3/8"2 1/2" 9 FT. HORIZ. 1/2"3" THROUGH 5" 10 FT. HORIZ. 1/2"6" 10 FT. HORIZ. 5/8"8" 10 FT. HORIZ. 3/4"ALL SIZES 10 FT. VERT.d. PVC PIPEPIPE DIAMETERSPACINGSUPPORT ROD DIAMETER1/2" THROUGH 2" 4 FT. HORIZ. 3/8"2 1/2" THROUGH 3 1/2" 4 FT. HORIZ. 1/2"4" THROUGH 5" 4 FT. HORIZ. 5/8"6" 4 FT. HORIZ. 3/4"8" 4 FT. HORIZ. 7/8"ALL SIZES 4 FT. VERT.e. SUPPORT CAST IRON SOIL PIPE AT EACH PIPE COUPLING AND CHANGE OF DIRECTION.13. PAINT STEEL PIPE, SUPPORTS, AND ANCHORS AND WOOD SUPPORTS INSTALLED IN EXPOSED EXTERIOR LOCATIONS WITH ONE COAT OFRUST INHIBITOR PRIMER AND A FINAL COAT OF ENAMEL PAINT. PAINT ELASTOMERIC FOAM INSULATION INSTALLED IN EXPOSEDEXTERIOR LOCATIONS WITH TWO COATS OF UV RESISTANT PAINT AS RECOMMENDED BY INSULATION MANUFACTURER.14. APPROVED MANUFACTURERS:a. HANGERS AND SUPPORTS: B-LINE, GRINELL, OR APPROVED EQUAL.b. FIBERGLASS INSULATION (PIPE AND DUCT): KNAUF, OR APPROVEDc. VALVES: CRANE, HAMMOND, JAMESBURY, KEYSTONE, MUELLER, NIBCO, RED AND WHITE, STOCKHAM, VICTAULIC, WATTS, ORAPPROVED EQUAL.DIVISION 22 - PLUMBING CONTINUED15. INSULATE WATER PIPING WITH ONE OF THE FOLLOWING:a. COLD WATER - ALL SIZES:1) 1/2" THICK, LIGHT DENSITY GLASS FIBER FORMED PIPE INSULATION WITH VAPOR BARRIER JACKET.b. HOT WATER - 1.5-INCH AND SMALLER:1) 1" THICK, LIGHT DENSITY GLASS FIBER FORMED PIPE INSULATION WITH VAPOR BARRIER JACKET.c. THERMAL CONDUCTIVITY (K): 0.30 BTU-IN/HR-FT2-OF AVERAGE MAXIMUM, AT 150 DEG F MEAN TEMPERATURE.Id. INSTALL SHEET METAL SHIELDS AT ALL PIPE HANGERS.16. ALL POTABLE WATER LINES ABOVE SLAB ON GRADE SHALL BE TYPE "L" HARD COPPER PIPE WITH WROUGHT FITTINGS, JOINTS MADEWITH "STAYSAFE" SOLDER.17. ALL POTABLE WATER LINES BELOW SLAB ON GRADE SHALL BE ONE OF THE FOLLOWING:a. TYPE "K" SOFT COPPER TUBE. USE CONTINUOUS LENGTHS OF TUBING BELOW SLAB AND INSTALL ALL FITTINGS ABOVE SLAB TOPREVENT JOINTS BELOW SLAB ON GRADE.18. DISINFECT ALL DOMESTIC HOT AND COLD WATER LINES BY MEANS OF CHLORINATION UPON COMPLETION OF THE SYSTEM, AND BEFOREUSE. AFTER CHLORINATION, OPEN ALL VALVES AND FLUSH WITH CLEAN WATER FOR TEN MINUTES OR UNTIL DISCHARGE MEASURES ARESIDUAL OF A MAXIMUMOF 0.5 PARTS PER MILLION OF CHLORINE. FURNISH THE ENGINEER AND OWNER WITH A CERTIFICATE OFCOMPLIANCE.19. INSTALL WATER SUPPLY PIPING SO THERE IS NO POSSIBILITY OF CROSS CONNECTION BETWEEN WATER SUPPLY AND WASTE, DRAINAGE,OR SOIL LINES.20. SANITARY WASTE, VENT AND STORM PIPING SYSTEMS: PROVIDE AND INSTALL ONE OF THE FOLLOWING:a. SERVICE WEIGHT CAST IRON NO-HUB SOIL PIPE AND FITTINGS WITH FM STYLE STAINLESS STEEL NO-HUB COUPLINGS.b. DWV PVC PIPING AND FITTINGS, EXCEPT FOR INSTALLATIONS WITHIN RETURN OR SUPPLY AIR PLENUMS.1. CELLUCORE PVC DWV NOT ALLOWED.21. INSTALL ALL HORIZONTAL SANITARY AND STORM PIPE WITH A SLOPE OF 1/4" PER FOOT.22. PLUMBING FIXTURES: ASSEMBLE PLUMBING FIXTURES, TRIM, FITTINGS, AND OTHER COMPONENTS ACCORDING TO MANUFACTURERS'WRITTEN INSTRUCTIONS. FOR WALL-HANGING FIXTURES, INSTALL OFF-FLOOR SUPPORTS AFFIXED TO BUILDING SUBSTRATE.a. USE CARRIER SUPPORTS WITH WASTE FITTING AND SEAL FOR BACK-OUTLET FIXTURES.b. USE CARRIER SUPPORTS WITHOUT WASTE FITTING FOR FIXTURES WITH TUBULAR WASTE PIPING.c. USE CHAIR-TYPE CARRIER SUPPORTS WITH RECTANGULAR STEEL UPRIGHTS FOR ACCESSIBLE FIXTURES.23. INSTALL FIXTURES DESIGNATED FOR USE BY THE HANDICAPPED PER REQUIREMENTS OF ICC A117.1, "ACCESSIBLE AND USABLEBUILDINGS AND FACILITIES"[; PUBLIC LAW 90-480, "ARCHITECTURAL BARRIERS ACT"; AND PUBLIC LAW 101-336, "AMERICANS WITHDISABILITIES ACT"; ] ABOUT PLUMBING FIXTURES FOR PEOPLE WITH DISABILITIES. INSTALL TRIP LEVER OF TANK-TYPE WATER CLOSETS,FLUSHOMETER VALVES OF WATER CLOSETS AND URINALS WITH LEVER HANDLE ON THE WIDE SIDE OF FIXTURE COMPARTMENTDEISGNATED AS AN ACCESSIBLE FIXUTRE FOR THE HANDICAPPED.24. INSTALL FIXTURES LEVEL AND PLUMB ACCORDING TO MANUFACTURERS' WRITTEN INSTRUCTIONS AND ROUGHING-IN DRAWINGS.25. INSTALL WATER-SUPPLY PIPING WITH STOP ON EACH SUPPLY TO EACH FIXTURE TO BE CONNECTED TO WATER DISTRIBUTION PIPING.ATTACH SUPPLIES TO SUPPORTS OR SUBSTRATE WITHIN PIPE SPACES BEHIND FIXTURES. INSTALL STOPS IN LOCATIONS WHERE THEYCAN BE EASILY REACHED FOR OPERATION.26. ALL SUPPLY PIPING LOCATED BELOW PLUMBING FIXTURES SHALL BE CHROME PLATED.27. ACCEPTABLE MANUFACTURERS:a. STAINLESS STEEL FIXTURES: AMERICAN STANDARD, EKLAY, JUST, KOHLER, WILLOUGHBY, OR APROVED EQUAL.b. FAUCETS: AMERICAN STANDARD, CHICAGO, DELTA, KOHLER, OR APPROVED EQUAL.c. FLOOR AND ROOF DRAINS, CLEANOUTS, FIXTURE CARRIERS, INTERCEPTORS: ANCON, JOSAM, SMITH, WADE, ZURN, OR APPROVEDEQUAL.DIVISION 22 SPECIFICATIONSNOT ALL SYMBOLS USED ON THIS PROJECT.SYMBOL DESCRIPTIONS ARE SUBJECT TO MODIFICATION ON THE DRAWINGS.c. DWV COPPER PIPE AND FITTINGS FOR 1 1/2" AND SMALER. DO NO USE AS BRANCH WASTE SERVING A URINAL.16. INSULATE STORM PIPE IN IT'S ENTIRETY FROM ROOF DRAIN TO THE FIRST FLOOR SLAB WITH THE FOLLOWING, INSULATEROOF DRAIN BODY.a. 1" THICK, LIGHT DENSITY GLASS FIBER FORMED PIPE INSULATION WITH VAPOR BARRIER JACKET.c. THERMAL CONDUCTIVITY (K): 0.30 BTU-IN/HR-FT2-OF AVERAGE MAXIMUM, AT 150 DEG F MEAN TEMPERATURE.d. INSTALL SHEET METAL SHIELDS AT ALL PIPE HANGERS.(NOT ALL ITEMS APPLY TO THIS PROJECT)CHECKED BYAPPROVED BYCOPYRIGHT NOTICE: THIS ARCHITECTURALAND ENGINEERING DRAWING IS GIVEN INCONFIDENCE AND SHALL BE USED ONLYPURSUANT TO THE AGREEMENT WITH RATIOARCHITECTS, INC. NO OTHER USE,DISSEMINATION OR DUPLICATION MAY BEMADE WITHOUT PRIOR WRITTEN CONSENTOF RATIO ARCHITECTS, INC. ALL COMMONLAW RIGHTS OF COPYRIGHT ANDOTHERWISE ARE HEREBY SPECIFICALLYRESERVED.SHEET TITLESHEET NUMBERKEY PLANPROJECT NO.REISSUENOwnerElectrical EngineerPlumbing EngineerArchitect227 Fayetteville Street, Suite 301Raleigh, North Carolina 27601919-821-0805RATIO Architects, Inc.11939 N. Meridian StreetCarmel, IN 46033(317) 730-2641Blue Horseshoe Solution11939 N. Meridian St.Carmel, IN 46033Blue HorseshoeSolutionsMechanical Engineer2649 Commerce BlvdCincinnati, Ohio 45241(513) 772-7545Perfection Group, Inc.02000.0001934 N. Illinois StreetIndianapolis, Indiana 46202(317) 921-5115Barth Electric Co., Inc.9100 Keystone CrossingIndianapolis, Indiana 46240(317) 810-4141Applied Engineering Services, Inc.CONSTRUCTION DOCUMENTS04.04.20174/4/17P001MBWDSJPLUMBING SYMBOLSABBREVIATIONSANDSPECIFICATIONS
FUTURE TENANT111FUTURE TENANT110ELEC107JAN106SOUTH CORRIDOR103SFUTURE TENANT109WOMEN104MEN105LOBBY102VESTIBULE101STAIR 2S-2STAIR 1S-1RISERR-1A12BCDEFGH34C.5D.13.23.8D.5C.4D.2P.2P.3F.5G.5E.5D.6B.5A.5P.13.42.81.42.61 1/2"V2"WSDFDLAV1 1/2"V UP1 1/2"W2"WCOCONNECTTO BUILDINGROUGH-IN11.SEE DRAWING P001 FOR GENERAL NOTES, LEGEND AND SPECIFICATIONS.GENERAL NOTES:EXISTING BUILDING SERVICES NOT IN CONTRACT.PLAN NOTES:1SCALE:FIRST FLOOR PLUMBING PLAN1/8" =1'-0"CHECKED BYAPPROVED BYCOPYRIGHT NOTICE: THIS ARCHITECTURALAND ENGINEERING DRAWING IS GIVEN INCONFIDENCE AND SHALL BE USED ONLYPURSUANT TO THE AGREEMENT WITH RATIOARCHITECTS, INC. NO OTHER USE,DISSEMINATION OR DUPLICATION MAY BEMADE WITHOUT PRIOR WRITTEN CONSENTOF RATIO ARCHITECTS, INC. ALL COMMONLAW RIGHTS OF COPYRIGHT ANDOTHERWISE ARE HEREBY SPECIFICALLYRESERVED.SHEET TITLESHEET NUMBERKEY PLANPROJECT NO.REISSUENOwnerElectrical EngineerPlumbing EngineerArchitect227 Fayetteville Street, Suite 301Raleigh, North Carolina 27601919-821-0805RATIO Architects, Inc.11939 N. Meridian StreetCarmel, IN 46033(317) 730-2641Blue Horseshoe Solution11939 N. Meridian St.Carmel, IN 46033Blue HorseshoeSolutionsMechanical Engineer2649 Commerce BlvdCincinnati, Ohio 45241(513) 772-7545Perfection Group, Inc.02000.0001934 N. Illinois StreetIndianapolis, Indiana 46202(317) 921-5115Barth Electric Co., Inc.9100 Keystone CrossingIndianapolis, Indiana 46240(317) 810-4141Applied Engineering Services, Inc.CONSTRUCTION DOCUMENTS04.04.20174/4/17P301MBWDSJFIRST FLOORPLUMBING PLAN
A12BCDEFGH34C.5D.13.23.8D.5C.4D.2F.5G.5E.5D.6B.5A.5D.73.42.81.42.6157 SFMARK./SALESPRIVATEOFFICE218209 SFLARGETEAMINGROOM226157 SFDEVELOP.PRIVATEOFFICE227161 SFMEDIUMENCLAVE228111 SFCHANGINGROOM22969 SFMOTHERSROOM22468 SFSMALLENCLAVE225274 SFLARGETEAMINGROOM211134 SFMEDIUMENCLAVE213157 SFMARK./SALESPRIVATEOFFICE216157 SFMARK./SALESPRIVATEOFFICE21522 SFSTORAGE230359 SFSTORAGE214770 SFTRAINING2211208 SFDEVELOPMENT232164 SFINTERNS2311087 SFOPEN LOUNGEAREA220759 SFMARKETING/SALES212131 SFMEDIUMENCLAVE219TOUCHDOWNAREA223TOUCHDOWNAREA222157 SFMARK./SALESPRIVATEOFFICE217FD-1L-1SH-1DWH-1122"V3/4"CW3451 1/2"V3/4"CW1/2"HW1212"WSINK2"WSINK2"WCO2"W1.SEE DRAWING P001 FOR GENERAL NOTES, LEGEND AND SPECIFICATIONS.2.RUN ALL PIPE AS CLOSE TO BEAMS AND JOISTS AS POSSIBLE . CONCEAL FROMSIGHT AS MUCH AS POSSIBLE.GENERAL NOTES:PLAN NOTES:1SCALE:SECOND FLOOR PLUMBING PLAN1/8" =1'-0"EXISTING BUILDING SERVICES NOT IN CONTRACT.CONNECT TO EXISTING BUILDING ROUGH-IN.EXTEND 1/2"HW AND 1/2"CW TO SHOWER VALVE, 1 1/2"V FROM BELOW.INSTALL WATER HEATER HIGH IN CEILING SPACE, EXTEND 3/4"CW TO AND 3/4"HWFROM WATER HEATER. PROVIDE UNIONS AND SERVICE VALVES.234CHECKED BYAPPROVED BYCOPYRIGHT NOTICE: THIS ARCHITECTURALAND ENGINEERING DRAWING IS GIVEN INCONFIDENCE AND SHALL BE USED ONLYPURSUANT TO THE AGREEMENT WITH RATIOARCHITECTS, INC. NO OTHER USE,DISSEMINATION OR DUPLICATION MAY BEMADE WITHOUT PRIOR WRITTEN CONSENTOF RATIO ARCHITECTS, INC. ALL COMMONLAW RIGHTS OF COPYRIGHT ANDOTHERWISE ARE HEREBY SPECIFICALLYRESERVED.SHEET TITLESHEET NUMBERKEY PLANPROJECT NO.REISSUENOwnerElectrical EngineerPlumbing EngineerArchitect227 Fayetteville Street, Suite 301Raleigh, North Carolina 27601919-821-0805RATIO Architects, Inc.11939 N. Meridian StreetCarmel, IN 46033(317) 730-2641Blue Horseshoe Solution11939 N. Meridian St.Carmel, IN 46033Blue HorseshoeSolutionsMechanical Engineer2649 Commerce BlvdCincinnati, Ohio 45241(513) 772-7545Perfection Group, Inc.02000.0001934 N. Illinois StreetIndianapolis, Indiana 46202(317) 921-5115Barth Electric Co., Inc.9100 Keystone CrossingIndianapolis, Indiana 46240(317) 810-4141Applied Engineering Services, Inc.CONSTRUCTION DOCUMENTS04.04.20174/4/17P302MBWDSJSECOND FLOORPLUMBING PLAN
A12BCDEFGH34C.5D.13.23.8D.5D.2F.5G.5E.5D.6B.5A.53.42.81.42.61.5.209 SFLARGETEAMINGROOM340175 SFSTORAGE345158 SFCONSULT.PRIVATEOFFICE346224 SFDATA CENTER32363 SFPANTRY33088 SFSMALLENCLAVE33188 SFSMALLENCLAVE324153 SFADMIN.OFFICE322155 SFADMINOFFICE321153 SFADMIN.OFFICE320161 SFCONSULT.PRIVATEOFFICE33473 SFSMALLENCLAVE353209 SFLARGETEAMINGROOM341179 SFIT SERVERROOM332199 SFLARGETEAMINGROOM312163 SFCOPY CENTER333251 SFPRESIDENT'SOFFICE316153 SFEXECUTIVEOFFICE317153 SFEXECUTIVEOFFICE318174 SFEXECUTIVEOFFICE315171 SFEXECUTIVEOFFICE314104 SFSTORAGE313169 SFCONSULTPRIVATEOFFICE347172 SFCONSULT.PRIVATEOFFICE350202 SFLARGETEAMINGROOM343202 SFLARGETEAMINGROOM342501 SFBOARD ROOM325159 SFCONSULT.PRIVATEOFFICE337163 SFCONSULTPRIVATEOFFICE338159 SFCONSULT.PRIVATEOFFICE335146 SFMEDIUMENCLAVE349208 SFMEDIUMENCLAVE344150 SFCONSULT.PRIVATEOFFICE351107 SFMEDIUMENCLAVE352742 SFMAINRECEPTION326103 SFMEDIUMENCLAVE311365 SFCAFE329194 SFCOFFEE BAR327393 SFLOUNGE3281713 SFCONSULTING3362769 SFCONSULTING348223 SFCOLLABORATIONAREA3391333 SFCONSULTING3101254 SFADMINISTRATION3191 1/2"V212121213S-2DISP-1DHW-241/2"CW5F-1S-1F-163/4"CW1 1/2"V1 1/2"V1/2"CW7GENERAL NOTES:PLAN NOTES:1SCALE:THIRD FLOOR PLUMBING PLAN1/8" =1'-0"1.SEE DRAWING P001 FOR GENERAL NOTES, LEGEND AND SPECIFICATIONS.2.RUN ALL PIPE AS CLOSE TO BEAMS AND JOISTS AS POSSIBLE . CONCEAL FROMSIGHT AS MUCH AS POSSIBLE.EXISTING BUILDING SERVICES NOT IN CONTRACT.CONNECT TO EXISTING BUILDING ROUGH-IN.1/2"HW AND 1/2"CW DROP, 2"W DOWN AND 1 1/2"V RISE.INSTALL WATER HEATER HIGH IN CEILING SPACE, EXTEND 3/4"CW TO AND 3/4"HWFROM WATER HEATER. PROVIDE UNIONS AND SERVICE VALVES.1/2"CW DROP, 2"W DOWN AND 1 1/2"V RISE. RUN CW THRU FILTER FOR SINK ANDEXTEND CW INTO CABINET AND ROUGH-IN FOR 3 COFFEE MAKERS BELOWCOUNTER TOP, FIELD VERIFY ALL REQUIREMENTS.PROVIDE LABOR AND MATERIAL AND HOOK-UP DISH WASHER AND DISPOSALCOMPLETE. EXTEND HW AND W FOR DISH WASHER.1/2"CW DROP AND ROUGH-IN FOR COFFEE MAKER BELOW COUNTER TOP, FIELDVERIFY ALL REQUIREMENTS.234567CHECKED BYAPPROVED BYCOPYRIGHT NOTICE: THIS ARCHITECTURALAND ENGINEERING DRAWING IS GIVEN INCONFIDENCE AND SHALL BE USED ONLYPURSUANT TO THE AGREEMENT WITH RATIOARCHITECTS, INC. NO OTHER USE,DISSEMINATION OR DUPLICATION MAY BEMADE WITHOUT PRIOR WRITTEN CONSENTOF RATIO ARCHITECTS, INC. ALL COMMONLAW RIGHTS OF COPYRIGHT ANDOTHERWISE ARE HEREBY SPECIFICALLYRESERVED.SHEET TITLESHEET NUMBERKEY PLANPROJECT NO.REISSUENOwnerElectrical EngineerPlumbing EngineerArchitect227 Fayetteville Street, Suite 301Raleigh, North Carolina 27601919-821-0805RATIO Architects, Inc.11939 N. Meridian StreetCarmel, IN 46033(317) 730-2641Blue Horseshoe Solution11939 N. Meridian St.Carmel, IN 46033Blue HorseshoeSolutionsMechanical Engineer2649 Commerce BlvdCincinnati, Ohio 45241(513) 772-7545Perfection Group, Inc.02000.0001934 N. Illinois StreetIndianapolis, Indiana 46202(317) 921-5115Barth Electric Co., Inc.9100 Keystone CrossingIndianapolis, Indiana 46240(317) 810-4141Applied Engineering Services, Inc.CONSTRUCTION DOCUMENTS04.04.20174/4/17P303MBWDSJTHIRD FLOORPLUMBING PLAN
A 1"36" DIASLOPE TO DRAINDEEPSEAL P-TRAPTOP OF FLOOR SLABSCALE:TYPICAL FLOOR DRAIN DETAILNONEENLARGE EXISTING OPENINGSEALMECHANICALEXISTING WALLPIPE& NEW SLEEVESCALE:WALL PENETRATION DETAILNONECLOCKING NUTSUPPORT NUTHEAVY DUTYCLEVIS HANGER14 GUAGE ZINK COATEDAT LEAST 6" LONGSHEET STEEL SADDLE,INSULATION6" LONG HARDWOOD BLOCK SHAPEDPIPETO FIT PIPE AND HANGERPIPEINSULATIONHANGER RODSCALE:PIPE HANGER (6" & SMALLER) DETAILNO SCALEBFD-2 & FD-3SCALE:INSTANEOUS DOMESTICWATER HEATERPIPING DIAGRAMNONED DOMESTICWATERHEATERCWHWREDUCERTYPICALCHECKED BYAPPROVED BYCOPYRIGHT NOTICE: THIS ARCHITECTURALAND ENGINEERING DRAWING IS GIVEN INCONFIDENCE AND SHALL BE USED ONLYPURSUANT TO THE AGREEMENT WITH RATIOARCHITECTS, INC. NO OTHER USE,DISSEMINATION OR DUPLICATION MAY BEMADE WITHOUT PRIOR WRITTEN CONSENTOF RATIO ARCHITECTS, INC. ALL COMMONLAW RIGHTS OF COPYRIGHT ANDOTHERWISE ARE HEREBY SPECIFICALLYRESERVED.SHEET TITLESHEET NUMBERKEY PLANPROJECT NO.REISSUENOwnerElectrical EngineerPlumbing EngineerArchitect227 Fayetteville Street, Suite 301Raleigh, North Carolina 27601919-821-0805RATIO Architects, Inc.11939 N. Meridian StreetCarmel, IN 46033(317) 730-2641Blue Horseshoe Solution11939 N. Meridian St.Carmel, IN 46033Blue HorseshoeSolutionsMechanical Engineer2649 Commerce BlvdCincinnati, Ohio 45241(513) 772-7545Perfection Group, Inc.02000.0001934 N. Illinois StreetIndianapolis, Indiana 46202(317) 921-5115Barth Electric Co., Inc.9100 Keystone CrossingIndianapolis, Indiana 46240(317) 810-4141Applied Engineering Services, Inc.CONSTRUCTION DOCUMENTS04.04.20174/4/17P501MBWDSJPLUMBING DETAILS
EXTERIOR COFCO3"W2"W STUB & CAP FORFUTURECONNECTION ATFF - 2.25', TYPICAL2"W STUB & CAP FORFUTURE CONNECTIONBUILDINGEXTERIORWALLFCO3"WEXTERIOR COFCO2"W STUB & CAP FORFUTURE CONNECTIONBUILDINGEXTERIORWALLFCO1 1/2"V1 1/2"VWCWCWC
U
R
L
A
V
L
A
V
L
A
V
L
A
V
WCWC
F
D
F
D3"W3"W3"W3"W3"W2"W STUB & CAP FORFUTURECONNECTION ATFF - 2.25', TYPICAL3"W3"W3"W3"W3"W3"V2"W2"W4"V4"V3"V3"V4"W4"W4"W2"W2"W4"W4"W4"W4"V STACK4"W, TYPICALAT EA WC2"W1 1/2"W,TYPICAL AT EA LAV1 1/2"V1 1/2"VWCWCWC
U
R
L
A
V
L
A
V
L
A
V
L
A
V
WCWC
F
D
F
D 3"V2"W2"W2"V3"V4"V3"V3"V4"W2"W2"W4"W, TYPICALAT EA WC2"W1 1/2"W,TYPICAL AT EA LAV1 1/2"V1 1/2"VWCWCWC
U
R
L
A
V
L
A
V
L
A
V
L
A
V
WCWC
F
D
F
D 3"V2"W2"W4"V4"V3"V3"V4"W2"W2"W4"W, TYPICALAT EA WC2"W1 1/2"W,TYPICAL AT EA LAV4"V STACK3"V3"V4"VFCO4"W4"W4"W3"WF
D
M
B
F
D
M
B
FCO4"W4"WF
D
M
B
WCOEWCEWC2"W3"W1 1/2"V4"W STACK3"W1 1/2"W1 1/2"V2"V2"W3"W2"V3"W1 1/2"WEWCEWCEWCEWC1 1/2"V2"W3"W1 1/2"W1 1/2"V2"V2"V1 1/2"V1 1/2"VFCO4"WFCO4"WFCO4"W4"W4"W4"W4"WEXTERIOR CO4"WFCOFCOFCO3"V3"V4"V4" VTRBUILDINGEXTERIORWALLF
D
F
D4"W4"W4"W4"W4"W4"W4"W4"W4"W4"V3"V STUB & CAP INCEILING SPACE FORFUTURE CONNECTION3"V STUB & CAP INCEILING SPACE FORFUTURE CONNECTION2"W STUB & CAP FORFUTURE CONNECTION,TYPICAL WHERE SHOWNCOCOCO3"W3"W3"W3"W3"W3"W2"W STUB & CAP FORFUTURE CONNECTION,TYPICAL WHERE SHOWN4" VTR4"V4"V2"W STUB & CAP FORFUTURE CONNECTION,TYPICAL WHERE SHOWNCO3"W3"W3"W3"W3"W2"W STUB & CAP FORFUTURE CONNECTION,TYPICAL WHERE SHOWN4"W STACK4" STACK VENT1 1/2"W,TYPICAL1 1/2"W,TYPICAL1 1/2"W,TYPICAL4"W4"V4"V4"V4"V STACKCO3"V STUB & CAP INCEILING SPACE FORFUTURE CONNECTION3"V3"V3"V4"V4"V4"VSCALE:WASTE AND VENT PIPING ISOMETRICNONEA 4"V STACK1.ALL PIPE SHOWN LIGHT IS EXISTING (IN THEMAIN BUILDING PROJECT).NOTE:L
A
V1 1/2"W1 1/2"WF
D
2"WS
D
2"W2"W1 1/2"WCO1 1/2"V1 1/2"VCONNECT TO BUILDING VIN 2ND FLOOR CEILINGSPACEC
O
S
K
&
D
I
S
P
O
S
E
R1 1/2"W2"W2"WCOCONNECT TO EXISTINGBUILDING ROUGH-INCONNECT TO EXISTINGBUILDING ROUGH-INCONNECT TO EXISTINGBUILDING V IN 3RD FLOORCEILING SPACE1 1/2"V1 1/2"V2"WS
K1 1/2"W2"W1 1/2"V1 1/2"VCONNECT TOEXISTING BUILDING VIN 3RD FLOORCEILING SPACECONNECT TOEXISTING BUILDING WCHECKED BYAPPROVED BYCOPYRIGHT NOTICE: THIS ARCHITECTURALAND ENGINEERING DRAWING IS GIVEN INCONFIDENCE AND SHALL BE USED ONLYPURSUANT TO THE AGREEMENT WITH RATIOARCHITECTS, INC. NO OTHER USE,DISSEMINATION OR DUPLICATION MAY BEMADE WITHOUT PRIOR WRITTEN CONSENTOF RATIO ARCHITECTS, INC. ALL COMMONLAW RIGHTS OF COPYRIGHT ANDOTHERWISE ARE HEREBY SPECIFICALLYRESERVED.SHEET TITLESHEET NUMBERKEY PLANPROJECT NO.REISSUENOwnerElectrical EngineerPlumbing EngineerArchitect227 Fayetteville Street, Suite 301Raleigh, North Carolina 27601919-821-0805RATIO Architects, Inc.11939 N. Meridian StreetCarmel, IN 46033(317) 730-2641Blue Horseshoe Solution11939 N. Meridian St.Carmel, IN 46033Blue HorseshoeSolutionsMechanical Engineer2649 Commerce BlvdCincinnati, Ohio 45241(513) 772-7545Perfection Group, Inc.02000.0001934 N. Illinois StreetIndianapolis, Indiana 46202(317) 921-5115Barth Electric Co., Inc.9100 Keystone CrossingIndianapolis, Indiana 46240(317) 810-4141Applied Engineering Services, Inc.CONSTRUCTION DOCUMENTS04.04.20174/4/17P701MBWDSJPLUMBINGISOMETRICS &DIAGRAMS