HomeMy WebLinkAbout17030121 Building PlansABCDE12345671234567ABCDEwww. studio3design.netPhone: (317) 595.1000Fax: (317) 572.12368604 Allisonville Road, Suite 330Indianapolis, IN 46250THIS DRAWINGS IS THE PROPERTYOF STUDIO 3 DESIGN, INC. ALLRIGHTS RESERVEDPROJECT NUMBER:DATE:CERTIFICATION:SHEET DESCRIPTION:SHEET NUMBER:1700617006170061700602-24-1702-24-1702-24-1702-24-17COVER SHEETCOVER SHEETCOVER SHEETCOVER SHEETA000A000A000A000SPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOL13190 HAZEL DELL PKWYCARMEL, IN 46033SPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOL13190 HAZEL DELL PKWY13190 HAZEL DELL PKWY13190 HAZEL DELL PKWY13190 HAZEL DELL PKWYCARMEL, IN 46033CARMEL, IN 46033CARMEL, IN 46033CARMEL, IN 46033PERMIT SET............................................................................................................................INDIANAPOLIS, IN 462508604 ALLISONVILLE ROAD, SUITE 330KEVIN COPPEDGEKCOPPEDGE@STUDIO3DESIGN.NETPhone: (317) 572.1240STUDIO 3 DESIGN, INC.ArchitectDRAWING LISTSheetNumberSheet NameSheet IssueDateDRAWING LISTSheetNumberSheet NameSheet IssueDateARCHITECTUREA000 COVER SHEET12/16/13A001 INFORMATION SHEET12/20/13A002 LIFE SAFETY PLAN12/20/13A050 DEMOLITION FLOOR PLAN & REFLECTED CEILING PLAN 12/20/13A100 NEW FLOOR PLAN & REFLECTED CEILING PLAN 12/20/13A130 FINISH LEGEND & FINISH MATERIALS 12/27/13A150 WALL TYPES & DETAILS12/27/13A600 INTERIOR ELEVATIONS12/27/13ELECTRICALE100 DEMOLITION & NEW ELECTRICAL PLAN 02/22/17MECHANICALM100 NEW MECHANICAL PLAN12/27/13PLUMBINGP100 NEW PLUMBING PLAN12/27/13DRAWING LISTVICINITY MAPPROJECT TEAMPROJECT LOCATIONRevision ScheduleRevision Number Revision Date Revision Description
60" MIN.18"FRONT APPROACHES48" MIN.12"XNOTE:x = 12" MIN. IF DOOR HASBOTH A LATCH & CLOSERYXHINGE SIDE APPROACHESNOTE:x = 36" MIN. IF Y = 60";X = 42" MIN. IF Y = 54"48" MIN.24"NOTE:Y = 54" MIN. IF DOOR HAS CLOSERY42" MIN.12"XNOTE:Y = 48" MIN. IF DOOR HASBOTH A LATCH & CLOSER54" MIN.42" MIN.24"40" MAX.TO SPOUTNOTE: SEE SPECIFICATIONS FOR TOILET ROOMACCESSORIES MOUNTING HEIGHTS.ELECTRIC WATERCOOLERTELEPHONE48" MAX.34" MAX.MIRRORTO REFLECTINGSURFACEDIAPER DISPENSEROR SANITARY NAPKINDISPENSERWASTE RECEPTACLESOAPDISPENSERNOTE: MOUNT ALL NON-HANDICAP ACCESSORIESACCORDING TO MANUFACTURER'SRECOMMENDATIONS.FIREEXTINGUISHERCABINET48" MAX.48" MAX.PAPER TOWELDISPENSER48" MAX.BUILDING / INTERIOR ELEVATION REFERENCEELEVATION REF.SHEET REF.WINDOW REFERENCEAELEVATION OR WORK POINT?NORTHORIENTATION REFERENCEDOOR SYMBOL??ROOM INDENTIFICATIONWALL TYPE1PLAN KEY NOTEDEMOLITION PLAN KEY NOTENEW DOOR / RELOCATED DOOREXISTING DOORDEMO DOOR / WALL DEMOEXISTING WALLNEW WALLEXISTING WALL TO BE REMOVEDPARTIAL HEIGHT WALL5CA600DETAIL REFERENCE1AABCDE12345671234567ABCDEwww. studio3design.netPhone: (317) 595.1000Fax: (317) 572.12368604 Allisonville Road, Suite 330Indianapolis, IN 46250THIS DRAWINGS IS THE PROPERTYOF STUDIO 3 DESIGN, INC. ALLRIGHTS RESERVEDPROJECT NUMBER:DATE:CERTIFICATION:SHEET DESCRIPTION:SHEET NUMBER:1700617006170061700602-24-1702-24-1702-24-1702-24-17INFORMATIONINFORMATIONINFORMATIONINFORMATIONSHEETSHEETSHEETSHEETA001A001A001A001SPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOL13190 HAZEL DELL PKWYCARMEL, IN 46033GENERAL PROJECT NOTESCONTRACTOR'S RESPONSIBILITIES:1. SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, EXISTING CONDITIONS, AND/OR DESIGN INTENT, THECONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ARCHITECT PRIOR TO BID SUBMITTAL PRIOR TOPROCEEDING WITH ANY WORK, OR RELATED WORK IN QUESTION.2. THESE CONTRACT DOCUMENTS ARE INTENDED TO DESCRIBE ONLY THE SCOPE AND APPEARANCE OF THE REAL PROPERTY IMPROVEMENTS,INCLUDING THE PERFORMANCE AND LEVEL OF QUALITY EXPECTED OF ITS COMPONENTS. IT IS INCUMBENT UPON THE CONTRACTOR TO INSURETHAT ALL WORK COMPLETED AND MATERIALS INSTALLED BE IN FULL COMPLIANCE, AS A MINIMUM STANDARDS, WITH ALL APPLICABLE CODES,REGULATIONS AND ORDINANCES HAVING JURISDICTION.3. THESE CONTRACT DOCUMENTS DO NOT ATTEMPT TO INSTRUCT THE CONTRACTOR IN THE DETAILS OF HIS TRADE. THEY ARE PERFORMANCESPECIFICATIONS IN THAT THEY DO REQUIRE THAT ALL MANUFACTURED ITEMS, MATERIALS AND EQUIPMENT BE INSTALLED IN STRICTACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED SPECIFICATIONS, EXCEPT IN THE CASE WHERE THE CONTRACT DOCUMENTS AREMORE STRINGENT. ANY MISCELLANEOUS ITEMS OR MATERIALS NOT SPECIFICALLY NOTED, BUT REQUIRED FOR PROPER INSTALLATION SHALLBE FURNISHED AND INSTALLED BY THE CONTRACTOR(S) RESPONSIBLE FOR THE AFFECTED PORTION OF WORK.4. ALL WORK SHALL BE WARRANTED SATISFACTORY, IN MATERIALS AND WORKMANSHIP, FOR A MINIMUM PERIOD OF ONE (1) YEAR, OR FOR THEPERIOD OF WARRANTY CUSTOMARY, OR STIPULATED FOR, THE TRADE, CRAFT, OR PRODUCT, WHICHEVER IS LONGER. THEREFORE, ONLYCOMPETENT MECHANICS CAPABLE OF PRODUCING GOOD WORKMANSHIP CUSTOMARY TO THE TRADE SHALL BE USED.5. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER, OR THE AUTHORIZED, AGENT, TO DETERMINE ALL EXISTING MATERIALS TO BESALVAGED AND RETAINED BY THE OWNER. THE CONTRACTOR SHALL REMOVE SALVAGEABLE MATERIALS FROM THE SPACE AND STORE IN ALOCATION AS DIRECTED BY THE OWNER. ALL OTHER MATERIALS, RUBBISH, AND DEBRIS, SHALL BE REMOVED AND PROMPTLY DISPOSED OF BYTHE CONTRACTOR AT AN OFFSITE LOCATION. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ASSURE THAT ALL PROPERTYIMPROVEMENTS (I.E. PARTITIONS, DOORS, FRAMES, CABINETS, CEILING GRID, CEILING TILE, AND THE ELECTRICAL AND MECHANICAL DEVICES,ETC.) WHICH ARE TO REMAIN, ARE PROTECTED FROM DAMAGE OF ANY KIND.6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING WORK WHICH IS TO REMAIN, AND DETERMINING WHETHER ORNOT IT CAN BE REPAIRED AND/OR RECONDITIONED TO MATCH AND BLEND WITH NEW MATERIALS AND COMPONENTS. THEY SHALL OBTAIN THEOWNER'S APPROVAL OF THE SCOPE AND LIMIT OF SAID WORK PRIOR TO STARTING CONSTRUCTION AND RECOMMEND AN ALLOWANCE IFNECESSARY. NO CHANGE ORDERS SHALL BE ACCEPTED FOR COMPLETED WORK THAT DOES NOT CONFORM TO THE STANDARDS ESTABLISHEDAT THE TIME OF BID ACCEPTANCE.7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH THE PROJECT SCOPE OF WORK, BUILDING STANDARDS,SCHEDULE AND DEADLINES. THE CONTRACTOR SHALL FURTHER BE RESPONSIBLE FOR ADVISING THE OWNER OF ALL LONG LEAD TIME ITEMSAFFECTING THE PROJECT SCHEDULE AND SHALL, UPON REQUEST FROM THE OWNER, SUBMIT ORDER CONFIRMATIONS AND DELIVERY DATESFOR SUCH LONG LEAD TIME ITEMS TO THE OWNER.8. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING OWNER ACCESS TO THE SPACE AND THE ONGOING CONSTRUCTION WORK.DISRUPTIVE OR POTENTIALLY HAZARDOUS CONSTRUCTION ACTIVITIES OCCURRING WITHIN OR ADJACENT TO OCCUPIED SPACE SHALL BECOORDINATED TO OCCUR AFTER NORMAL OFFICE HOURS, SO AS TO MINIMIZE DISTURBANCE TO BUILDING OCCUPANTS.9. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING OWNER FOR DELIVERY TO THE SPACE OF ALL BUILDING MATERIALS, AND SHALLARRANGE FOR USAGE OF THE FREIGHT ELEVATOR (OR SUCH ELEVATOR DESIGNATED IF APPLICABLE). IF DELIVERY OF BUILDING MATERIALSINVOLVES THE USE OF OTHER FACILITIES, THE CONTRACTOR SHALL COORDINATE SUCH ACTIVITIES IN SUCH A MANNER WHICH POSES NOHAZARD TO ANY PERSONNEL WITHIN OR AROUND THE BUILDING OR BUILDING SITE.10. ALL CONTRACTOR OR SUPPLIER REQUESTS FOR SUBSTITUTIONS OF SPECIFIED ITEMS SHALL BE SUBMITTED IN WRITING ACCOMPANIED BY THEALTERNATIVE PRODUCT INFORMATION TO THE ARCHITECT. ALL SUBSTITUTIONS SHALL BE SUBMITTED TO THE ARCHITECT, NO LATER THAN (10)WORKING DAYS PRIOR TO BID OPENING DATE. SUBSTITUTIONS SHALL ONLY BE CONSIDERED IF THEY DO NOT SACRIFICE QUALITY,APPEARANCE, AND FUNCTION. UNDER NO CIRCUMSTANCES WILL THE OWNER BE REQUIRED TO PROVE THAT A PRODUCT PROPOSED FORSUBSTITUTION IS OR IS NOT EQUAL QUALITY TO THE PRODUCT SPECIFIED.11. UNDER NO CIRCUMSTANCES SHALL THE CONTRACTOR SCALE THE DRAWINGS TO DETERMINE THE DIMENSIONS. SEE FLOOR PLAN FORDIMENSION LOCATIONS.12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ALL SELECTED MATERIALS WHICH SHALL BE COMPLETE IN ALLRESPECTS PRIOR TO THE FINAL ACCEPTANCE, UNLESS OTHERWISE NOTED.13. THE CONTRACTOR SHALL BE PRESERVE ALL PRINTED INSTRUCTIONS AND WARRANTIES THAT ARE PROVIDED WITH EQUIPMENT OR MATERIALSUSED, AND DELIVER SAID IN PRINTED MANNER TO THE OWNER AT THE TIME(S) DESIGNATED FOR O & M MANUAL DISBURSEMENTS. THECONTRACTOR SHALL INSTRUCT THE OWNER OR OWNERS REPRESENTATIVE IN THE PROPER USE OF THE EQUIPMENT FURNISHED BY THEIRTRADE.14. GENERAL CONTRACTOR IS TO PROVIDE A THOROUGH CONSTRUCTION CLEAN-UP AT CLOSE-OUT, INCLUDING VACUUMING AND CLEANING ALLCARPETING.15. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF CUSTOM MILLWORK, CUSTOM FABRICATION OR MANUFACTURE, AND PHYSICAL SAMPLESOF ALL FINISH MATERIALS SPECIFIED TO THE ARCHITECT FOR REVIEW AND APPROVAL BY THE OWNER. SEE SPECIFICATIONS.16. REVIEWED SHOP DRAWINGS AND SCHEDULES PREPARED BY OTHERS SHALL NOT BE CONSTRUED TO BE PART OF THE CONTRACT DOCUMENTS,AS THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR DRAWINGS, SCHEDULES, AND/OR SPECIFICATIONS FOR WORK ON THE PROJECTPREPARED OR ACCOMPLISHED BY OTHERS.17. THE ARCHITECT WILL REVIEW THE DRAWINGS AND SAMPLES SUBMITTED BY THE CONTRACTOR (FOLLOWING A REVIEW BY THE GENERALCONTRACTOR) FOR CONFORMITY WITH THE INFORMATION CONTAINED IN THE CONSTRUCTION DOCUMENTS.18. CONTRACTOR TO FOLLOW ALL BUILDING STANDARDS, INTERIM LIFE SAFETY MEASURES AND COORDINATE SCHEDULING OF WORK WITHAFFECTED OCCUPANTS (IF APPLICABLE) PRIOR TO STARTING.19. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AND NOTIFY ARCHITECT, IN WRITING, OF ALL DISCREPANCIES.CONTRACTOR TO REVIEW AND RECORD EXISTING CEILING FIELD CONDITIONS, LIGHT FIXTURE AND MEP SUPPLY/RETURN LOCATIONS,SPRINKLER HEADS, AND ALL OTHER CEILING ITEMS LOCATIONS PRIOR TO CONSTRUCTION. DISCREPANCIES IN THIS INFORMATION SHALL BERECORDED IN THE CONSTRUCTION FIELD SET.20. THE GENERAL CONTRACTOR AND EACH TRADE IS RESPONSIBLE FOR REVIEWING AND COORDINATING ALL NEW WORK WITH ALL EXISTINGCONDITIONS AND WITH ALL OTHER TRADES.21. ALL CONSTRUCTION TO MEET CURRENT NATIONAL, STATE AND LOCAL CODES, ORDINANCES AND ADA REGULATIONS.22. PREP ALL WALL SURFACES TO RECEIVE NEW PAINT OR WALL COVERING FINISH. PATCH ALL EXISTING HOLES IN AREAS TO RECEIVE NEWFINISHES. SAND ALL NEW TO EXISTING TRANSITIONS SMOOTH PRIOR TO PAINTING. PATCH ALL AREAS WHERE RECEPTACLE OR FIXTURES AREREMOVED. REMOVE EMERGENCY LIGHTS, SIGNAGE, THERMOSTATS, FIRE STROBES, ETC. PRIOR TO PAINTING AND REINSTALL WHENCOMPLETE.23. UNLESS NOTED OTHERWISE, THE TERM "PROVIDE" INDICATES TO SUPPLY AND INSTALL COMPLETE, FOLLOWING MANUFACTURER'SINSTRUCTIONS AND RECOMMENDATIONS AND SUPPLYING AND INSTALLING ALL ASSOCIATED ITEMS AND ACCESSORIES AS REQUIRED FORCOMPLETE INSTALLATION.24. GENERAL CONTRACTOR SHALL ACCOMMODATE TENANTS VENDORS DURING CONSTRUCTION AND WORK WITH THE OWNER TO SCHEDULEINSTALLATION OF OWNER SUPPLIED AND INSTALLED ITEMS.25. WHERE RATED WALLS ARE INDICATED, ENTIRE WALL ASSEMBLY SHALL BE CONTINUOUS AS SHOWN OR IMPLIED ON THE CONTRACTDOCUMENTS.26. WHERE GAUGE OF METAL STUDS ARE NOT SPECIFICALLY SHOWN OR NOTED, PROVIDE GAUGE AS INDICATED IN THE GENERAL WALL TYPENOTES.27. CONTRACTOR TO REVISE, ADD OR RELOCATE FIRE STROBES, SPRINKLERS, AND OTHER LIFE SAFETY DEVICES AS NECESSARY TO MEET ALLAPPLICABLE CODES, MAINTAIN LIFE SAFETY AND/OR AS STIPULATED BY THE CONTRACT DOCUMENTS.28. COMMENCEMENT OF WORK BY A CONTRACTOR OR SUBCONTRACTOR, CONSTITUTES ACCEPTANCE OF THE CONDITIONS AND SURFACES INQUESTION. IF ANY SUCH CONDITIONS/SURFACES ARE UNACCEPTABLE, THE GENERAL CONTRACTOR SHOULD BE NOTIFIED AT ONCE BY THESUBCONTRACTOR AND NO WORK DONE UNTIL CONDITIONS ARE ACCEPTABLE.29. CONTRACTORS ARE TO FOLLOW ALL MANUFACTURERS RECOMMENDATIONS FOR INSTALLATION OF EQUIPMENT, MATERIALS, AND FINISHES.30. CONTRACTOR TO MAINTAIN ALL MCOR REQUIREMENTS INCLUDING NEGATIVE AIR PRESSURE, ANTE ROOMS, AND WALK-OFF MATS.31. CONTRACTOR TO PROVIDE DUST WALLS AT NECESSARY LOCATIONS.32. CONTRACTOR TO PROVIDE AND MAINTAIN INFECTION CONTROL REQUIREMENTS PER FACILITY'S INFECTION CONTROL PRACTITIONER.33. TRANSPORT OF MATERIALS AND DEBRIS SHALL BE CORRDINATED WITH THE FACILITY'S REPRESENTATIVES PRIOR TO THE START OFCONSTRUCTION.GENERAL NOTES1. CONTRACTOR TO VISIT SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS PRIOR TO START OF WORK.CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AND NOTIFY ARCHITECT, INWRITING, OF ALL DISCREPANCIES. CONTRACTOR TO DOCUMENT EXISTING FIELD CONDITIONS, LIGHT FIXTUREAND MEP SUPPLY/RETURN LOCATIONS, SPRINKLER HEADS, AND ALL OTHER CEILING ITEM LOCATIONS PRIOR TOCONSTRUCTION. THIS INFORMATION SHALL BE PROVIDED TO ARCHITECT FOR INCORPORATION INTO ACONSTRUCTION SET.2. THE GENERAL CONTRACTOR AND EACH TRADE IS RESPONSIBLE FOR REVIEWING AND COORDINATING ALL NEWWORK WITH ALL EXISTING CONDITIONS AND WITH ALL OTHER TRADES.3. CONTRACTOR IS RESPONSIBLE TO PATCH/REPAIR/SEAL ALL NEW & EXISTING PENETRATIONS INTO RATED WALLSTO MAINTAIN RATED ASSEMBLY.4. ALL PENETRATIONS IN AND THROUGH FIRE AND SMOKE RATED WALLS SHALL BE SLEEVED AND FIRE STOPPED ASNECESSARY TO MAINTAIN RATINGS.5. UNLESS NOTED OTHERWISE, THE TERM "PROVIDE" INDICATES TO SUPPLY AND INSTALL COMPLETE, FOLLOWINGMANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS AND SUPPLYING AND INSTALLING ALL ASSOCIATEDITEMS AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION.6. GENERAL CONTRACTOR SHALL COORDINATE ALL PHASES AND TIMING OF CONSTRUCTION WITH ARCHITECT,TENANT, AND BUILDING OWNER.7. ALL COSTS ASSOCIATED WITH THE PROTECTION OF EXISTING FACILITIES, UTILITIES, AND STRUCTURES WITHINTHE WORK ZONE AND OR WITHIN THE PATH ESTABLISHED BY THE CONTRACTOR TO EXECUTE THE WORK SHALLBE INCORPORATED IN THE CONTRACTOR'S BASE BID.FIELD VERIFICATION PRIOR TO BIDTHE CONTRACTOR AND HIS SUBCONTRACTORS ARE REQUIRED TO VISIT THE SITE ANDBECOME FAMILIAR WITH EXISTING CONDITIONS PRIOR TO THE ISSUANCE OF A BID. ALLCOSTS ASSOCIATED WITH THE PROTECTION OF EXISTING FACILITIES, UTILITIES, ANDSTRUCTURES (BOTH ABOVE AND BELOW GRADE AND AREA OF WORK) WITHIN THEWORK ZONE AND OR WITHIN THE PATH ESTABLISHED BY THE CONTRACTOR TOEXECUTE THE WORK SHALL BE INCORPORATED IN THE CONTRACTORS BASE BID.THE CONTRACTOR SHALL NOTIFY OWNER/DESIGN PROFESSIONAL (PRIOR TO BID) OFANY ITEMS DISCOVERED DURING FIELD VERIFICATION THAT THE CONTRACTOR FEELSREQUIRE ADDITIONAL CLARIFICATION FROM THE OWNER/DESIGN PROFESSIONAL INORDER TO APPROPRIATELY BID THE PROJECT.ABBREVIATIONSMAS MASONRYMAX MAXIMUMMB MARKER BOARDMECH MECHANICALMEZZ MEZZANINEMFR MANUFACTURERMIN MINIMUMMO MASONRY OPENINGO.D. OUTSIDE DIAMETERO.H. OPPOSITE HANDOH OVERHEADOPNG OPENINGOPP OPPOSITEP LAM PLASTIC LAMINATEPLWD PLYWOODQT QUARRY TILER RISERR.O. ROUGH OPENINGRA RETURN AIRREF REFERENCEREQ REQUIREDSA SUPPLY AIRSCH SCHEDULESEC SECTIONSF SQUARE FOOTSIM SIMILARSPECS SPECIFICATIONSSS STAINLESS STEELSTD STANDARDSTL STEELSUSP SUSPENDEDT.O. TOP OFTEL TELEPHONETV TELEVISIONTYP TYPICALU.O.N. UNLESS OTHERWISE NOTEDUR URINALVCT VINYL COMPOSITION TILEVERT VERTICALVT VINYL TILEW/ WITHW/O WITHOUTWB WOOD BASEWC WATER CLOSETWD WOODWH WATER HEATERWP WORKING POINTABBREVIATIONSA.F.F. ABOVE FINISHED FLOORACT ACOUSTICAL CEILING TILEAPP APPROXIMATEAWT ACOUSTICAL WALL TREATMENTB.O. BOTTOM OFBD BOARDBLKG BLOCKINGBOT BOTTOMC.J. CONTROL JOINTCAB CABINETCL CENTER LINECMU CONCRETE MASONRY UNITCOL COLUMNCONC CONCRETECONST CONSTRUCTIONCONT CONTINUOUSCPT CARPETCT CERAMIC TILECW COLD WATERD.F. DRINKING FOUNTAINDET DETAILDIM DIMENSIONDTL DETAILDWC DRINKING WATER COOLERDWG DRAWINGEA EACHEIFS EXTERIOR INSULATION FINISH SYSTEMEJ EXPANSION JOINTEL ELEVATIONETR EXISTING TO REMAINEXIST EXISTINGEXP EXPANSIONEXT EXTERIORFD FLOOR DRAINFE FIRE EXTINGUISHERFIN FINISHFL FLOORFT FEETGA GAUGEGYP GYPSUMHDW HARDWAREHM HOLLOW METALHORIZ HORIZONTALHVAC HEATING, VENTILATING & AIR COND.HW HOT WATERI.D. INSIDE DIAMETERJST JOISTJT JOINTKIT KITCHENLAM LAMINATELAV LAVATORYADA APPROACH LEGENDADA MOUNTING HEIGHTSDRAFTING SYMBOLSRevision ScheduleRevision Number Revision Date Revision Description
>>>>OVEN OVEN OVEN OVEN
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>FIRE EXTINGUISHER LOCATIONS (SEE SHEET A100)EXTSUITE/ BUILDING EXITFECPATH OF EGRESSAPPLICABLE CODES:2014 INDIANA BUILDING CODE (2012 INTERNATIONAL BUILDING CODE)2010 INDIANA ENERGY CONSERVATION CODE (675-ISE 19-4)2014 INDIANA FIRE CODE (2012 INTERNATIONAL FIRE CODE)2012 INDIANA PLUMBING CODE (2006 INDIANA PLUMBING CODE WITH 2012AMENDMENTS)2009 INDIANA ELECTRICAL CODE (2008 NFPA 70)2014 INDIANA MECHANICAL CODE (2012 INTERNATIONAL MECHANICAL CODE)2014 INDIANA FUEL GAS CODE (2012 INTERNATIONAL FUEL GAS CODE)2000 LIFE SAFETY CODE, CHAPTER 23 (NFPA 101)PROJECT LOCATION:13190 HAZEL DELL PKWYCARMEL, IN 46033OCCUPANCY:B OCCUPANCY (SEC. 309.1)SQUARE FOOTAGE:12,950 SF EXISTING BLDG 1,220 SF REMODELEDHEIGHT:BUILDING IS 1 STORYWIDTH OF EXITS:EXIT DOOR WIDTH PROVIDED AT THE RATE OF 0.15 INCHESPER OCCUPANT. (SEC. 1003.2.3)CONSTRUCTION TYPE:TYPE II-BFIRE SUPPRESSION SYSTEM:AUTOMATIC FIRE SUPPRESSION SYSTEM NOT REQUIRED.FIRE RESISTIVE CORRIDORS:NOT REQUIREDSMOKE RESISTIVE CORRIDOR DOORS:NOT REQUIREDHAZARDOUS ROOMS:NONEEXIT ACCESS TRAVEL DISTANCE:EXIT ACCESS TRAVEL DISTANCE:NOT TO EXCEED 300 FEET.DEAD END EXIT ACCESS:NOT TO EXCEED 50 FEET.OCCUPANT LOAD:100 SF PER OCCUPANT REQUIRED.#### SQUARE FEETPLUMBING COUNT:WATERCLOSETS: 1 PER 25 OCCUPANTS (MEN & WOMEN)LAVATORIES: 1 PER 40 OCCUPANTS (MEN & WOMEN)RESTROOMS - ARE EXISTING TO REMAIN (OR)# OF OCCUPANTS.WOMEN(# OF OCCUPANTS)MEN(# OF OCCUPANTS)WC = REQD.LAV = REQD.ALARMS / FIRE DETECTION:AUTOMATIC FIRE DETECTION REQUIRED (TABLE 407.6)ALARM SYSTEM PER SECTION 907.2.6.2ACCESSABILITY:PER BUILDING OCCUPANCY / ANSI REQUIREMENTSWC = REQD.LAV = REQD.CLASSROOM100RELOCATEDTOILET102PREP AREA103WORK ROOM105OFFICE104EXTEXTL1L1L1L2L2L3PROJECT LOCATIONHAZEL DELL CORNERSHOPPING CENTERABCDE12345671234567ABCDEwww. studio3design.netPhone: (317) 595.1000Fax: (317) 572.12368604 Allisonville Road, Suite 330Indianapolis, IN 46250THIS DRAWINGS IS THE PROPERTYOF STUDIO 3 DESIGN, INC. ALLRIGHTS RESERVEDPROJECT NUMBER:DATE:CERTIFICATION:SHEET DESCRIPTION:SHEET NUMBER:1700617006170061700602-24-1702-24-1702-24-1702-24-17LIFE SAFETY PLANLIFE SAFETY PLANLIFE SAFETY PLANLIFE SAFETY PLANA002A002A002A002SPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOL13190 HAZEL DELL PKWYCARMEL, IN 46033LIFE SAFETY PLAN LEGENDCODE SUMMARY NOTESLIFE SAFETY PLAN NOTESL1 PATH OF EGRESS.L2 BUILDING EXIT.L3 BRACKET MOUNTED FIRE EXTINGUISHER. 1/4" = 1'-0"A002PROPOSED FLOOR PLAN4ENOT TO SCALEKEY PLANNORTHRevision ScheduleRevision Number Revision Date Revision Description
D1D1D1D2D5D2D6D6D3D1D3D6D7D7D7D8D8R3R1R2R2R1R1R1R1R1R1R1R1R1R1R1R1R1R1R3R4R4R4R4R4R4R4R4R4R4R4R4R4R4R4R4R4R4R4RECESSED LIGHTNEW 2' X 4' RECESSED FLUORESCENTEXISTING CEILING TO REMAIN2' X 4' ACOUSTICAL CEILING TILENEW CEILING GRIDEXISTING CEILING GRIDWALL MOUNTED EXIT SIGNCEILING MOUNTED EXIT SIGN0'-0"CLG10'-0"XHVAC SUPPLY DIFFUSERHVAC RETURN GRILLESMOKE DETECTORSDEXISTING 2' X 4' RECESSED FLUORESCENTCEILING TYPEMATERIAL/DETAIL VARIATIONCEILING HEIGHTDIRECTIONAL RECESSED LEDPROJECT LOCATIONHAZEL DELL CORNERSHOPPING CENTERABCDE12345671234567ABCDEwww. studio3design.netPhone: (317) 595.1000Fax: (317) 572.12368604 Allisonville Road, Suite 330Indianapolis, IN 46250THIS DRAWINGS IS THE PROPERTYOF STUDIO 3 DESIGN, INC. ALLRIGHTS RESERVEDPROJECT NUMBER:DATE:CERTIFICATION:SHEET DESCRIPTION:SHEET NUMBER:1700617006170061700602-24-1702-24-1702-24-1702-24-17DDDDEEEEMMMMOOOOLLLLIIIITTTTIIIIOOOONNNN FFFFLLLLOOOOOOOORRRRPPPPLLLLAAAANNNN &&&& RRRREEEEFFFFLLLLEEEECCCCTTTTEEEEDDDDCEILING PLANCEILING PLANCEILING PLANCEILING PLANA050A050A050A050SPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOL13190 HAZEL DELL PKWYCARMEL, IN 46033GENERAL DEMOLITION NOTESA. SEE GENERAL NOTES ON CUTTING AND PATCHING OUTLINED ON SHEET A001 FORADDITIONAL INFORMATION.B. PERFORM ALL WORK UNDER ESTABLISHED PROJECT GUIDELINES.C. FIELD VERIFY EXISTING CONDITIONS AND COORDINATE DEMOLITION OR REMOVALWORK WITH CORRESPONDING NEW CONSTRUCTION WORK AND APPROPRIATETRADES PRIOR TO STARTING DEMOLITION WORK. IF DISCREPANCIES ARE FOUNDBETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS, NOTIFYARCHITECT IMMEDIATELY.D. DASHED LINES INDICATE EXISTING ITEMS TO BE REMOVED. UNLESS OTHERWISENOTED, CONTRACTOR SHALL BE RESPONSIBLE FOR THE OFF-SITE DISPOSAL OFALL DEMOLITION ITEMS.E. REMOVE ALL CONSTRUCTION DEBRIS FROM SITE DAILY. DO NOT ALLOW REFUSETO BLOCK CORRIDORS, STAIRS, OR ANY OTHER TRAFFIC AREAS.F. PROVIDE TEMPORARY FIRE AND LIFE SAFETY PROTECTION THROUGHOUTDURATION OF PROJECT.G. PATCH AND REPAIR ALL ADJACENT SURFACES DISTURBED/DAMAGED BYCONSTRUCTION. CLEAN ALL FLOOR SURFACES OF ADHESIVE AND OR GROUTRESIDUE PRIOR TO INSTALLATION OF NEW FLOORING MATERIAL.H. PROTECT ADJACENT EXISTING TO REMAIN CONSTRUCTION THROUGHOUTDURATION OF PROJECT. PROVIDE SHORING, BRACING OR SUPPORT AS REQUIREDTO PREVENT MOVEMENT OR SETTLEMENT OF EXISTING CONSTRUCTION.I. PROVIDE CONSTRUCTION BARRIER PARTITIONS BETWEEN AREAS OF WORK ANDOCCUPIED SPACES (IF APPLICABLE). PARTITIONS TO REMAIN INTACT THROUGHOUTCONSTRUCTION, INCLUDING COMPLETED WORK AND WORK UNDERCONSTRUCTION.K. WHERE BLOCKING AND/OR ELECTRICAL WORK IS REQUIRED IN EXISTING WALLCONSTRUCTION, CONTRACTOR TO CAREFULLY CUT-OUT GYPSUM BOARD ATAPPROPRIATE LOCATION. PATCH AND FINISH AREA PER CUTTING ANDPATCHING/FINISHING NOTES ON SHEET A001.L. REMOVE ALL EXISTING CONSTRUCTION ITEMS AND FINISHES MADE OBSOLETE BYOR IN CONFLICT WITH NEW CONSTRUCTION. VERIFY WITH ARCHITECT AND/OROWNER'S REPRESENTATIVE. REMOVE WIRING BACK TO SOURCE AT ALL OUTLETS,ETC. MADE OBSOLETE BY WALL REMOVAL OR ANY OTHER NEW CONSTRUCTION.M. REMOVE ALL ITEMS IN THEIR ENTIRETY UNLESS OTHERWISE NOTED. DESCRIPTIONOF PRIMARY ITEMS TO BE REMOVED IS GENERAL IN NATURE, AND REMOVAL OFSECONDARY COMPONENTS SUCH AS BLOCKING, SUPPORTS, ANCHORS, TRIM,ADHESIVE, PIPING, WIRING, ETC., RELATED TO PRIMARY ITEMS SHALL BE INCLUDED.N. RELOCATED ITEMS SHALL BE CLEANED AND PLACED IN STORAGE PER OWNER'SDIRECTIONS UNTIL ITEMS ARE READY TO BE REINSTALLED. IF ITEM IS DAMAGEDDURING DEMOLITION OR RELOCATION, IT SHALL BE REPAIRED WITH NEW ITEM ASAPPROVIDED BY OWNER AT NO EXPENSE TO OWNER.O. AT OWNER'S REQUEST, SALVAGED ITEMS SHALL BE TURNED OVER TO THE OWNEROR STORED IN AN AREA DESIGNATED BY THE OWNER.P. IF EXISTING ITEMS TO BE REMOVED OR DISTURBED ARE SUSPECTED ORDISCOVERED TO CONTAIN ASBESTOS OR OTHER HAZARDOUS MATERIALS, STOPDEMOLITION AND NOTIFY OWNER IMMEDIATELY.DEMO PLAN NOTESD1 DEMOLISH EXISTING WALL CONSTRUCTION COMPLETE TO EXTENTS INDICATED ONPLAN. PATCH EXISTING TO REMAIN WALL SURFACES TO PROVIDE A SMOOTH FLUSHFINISH WITH NEW WORK.D2 DEMOLISH EXISTING CHASE WALL TO EXTENTS INDICATED ON PLAN. PATCH ANDREPAIR REMAINING WALL SURFACES TO PROVIDE A SMOOTH FLUSH FINISH WITH NEWWORK.D3 DEMOLISH CASEWORK AND ALL RELATED ITEMS COMPLETE.D5 REMOVE RESTROOM ACCESSORIES & GRAB BARS. SAVE FOR RE-INSTALLATION IN NEWRESTROOM.D6 REMOVE PLUMBING FIXTURE. CAP PLUMBING AT THE FLOOR.D7 WATERLINES AND DRAINS STUBBED OUT AT THIS LOCATION, CAP AT THE FLOOR.D8 TRENCH EXISTING CONCRETE SLAB FOR INSTALLATION OF NEW ELECTRICAL ANDPLUMBING LINES TO NEW ISLANDS 1/4" = 1'-0"A050DEMOLITION PLAN4E 1/4" = 1'-0"A050DEMO REFLECTED CEILING PLAN1EDEMO REFLECTED CEILING PLAN NOTESR1 REMOVE EXISTING LIGHTING AS REQUIRED TO PROVIDE NEW LIGHTING LAYOUT.R2 REMOVE EXISTING HVAC AS REQUIRED TO PROVIDE NEW LAYOUT OF NEW LIGHTFIXTURE OR HVAC.R3 REMOVE CEILING TILE AND SECTION OF GRID AT LOCATION OF NEW LIGHT FIXTURE ORHVAC.R4 REMOVE CEILING TILE AT THIS LOCATION.REFLECTED CEILING PLAN LEGENDNOT TO SCALEKEY PLANNORTHRevision ScheduleRevision Number Revision Date Revision Description
OFFICE104WORK ROOM105RELOCATEDTOILET102MICROWAVES / WALL OVENS2' - 5 3/4"7' - 2"8' - 2"6' - 0"8' - 2"4' - 0"2' - 0"7' - 0"D/WFRIDG42' - 6"6' - 8 1/2" +/-FRIDG12' - 6"7' - 5 1/2"6' - 0"RECEPT/DISPLAY3' - 1 1/4"3' - 2"5' - 0"3' - 2"3' - 9"CLASSROOM100PREP AREA103EXIST.EXIST.EXIST.EXIST.102A611222245666889976121211113333A6005DA6002E13131313121212121013121215C6C6C6C6C6C6C6C6C6C6C6C6C6C6C6C6C6C6C6C6C5C5C5C5C5C5C5C5C5C5C2C3C7C7C7C7C7C7C7C7C7C7C7C7C7C7C7C7C7C6C6C6C6C6C8C8C8C8C8C8C8RECESSED LIGHTNEW 2' X 4' RECESSED FLUORESCENTEXISTING CEILING TO REMAIN2' X 4' ACOUSTICAL CEILING TILENEW CEILING GRIDEXISTING CEILING GRIDWALL MOUNTED EXIT SIGNCEILING MOUNTED EXIT SIGN0'-0"CLG10'-0"XHVAC SUPPLY DIFFUSERHVAC RETURN GRILLESMOKE DETECTORSDEXISTING 2' X 4' RECESSED FLUORESCENTCEILING TYPEMATERIAL/DETAIL VARIATIONCEILING HEIGHTDIRECTIONAL RECESSED LEDPROJECT LOCATIONHAZEL DELL CORNERSHOPPING CENTERABCDE12345671234567ABCDEwww. studio3design.netPhone: (317) 595.1000Fax: (317) 572.12368604 Allisonville Road, Suite 330Indianapolis, IN 46250THIS DRAWINGS IS THE PROPERTYOF STUDIO 3 DESIGN, INC. ALLRIGHTS RESERVEDPROJECT NUMBER:DATE:CERTIFICATION:SHEET DESCRIPTION:SHEET NUMBER:1700617006170061700602-24-1702-24-1702-24-1702-24-17NNNNEEEEWWWW FFFFLLLLOOOOOOOORRRR PPPPLLLLAAAANNNN &&&&RRRREEEEFFFFLLLLEEEECCCCTTTTEEEEDDDD CCCCEEEEIIIILLLLIIIINNNNGGGGPLANPLANPLANPLANA100A100A100A100SPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOL13190 HAZEL DELL PKWYCARMEL, IN 46033GENERAL FLOOR PLAN NOTESA. CONTRACTOR TO FOLLOW ALL BUILDING/PROJECT STANDARDS. PROVIDE INTERIMLIFE SAFETY MEASURES AND FOLLOW ALL STATE AND LOCAL BUILDING CODES. IFCONTRARY INSTRUCTIONS ARE CONTAINED HEREIN, REQUEST CLARIFICATIONFROM OWNER/ARCHITECT.B. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALLDIMENSIONS, JOB CONDITIONS, ETC.C. SEE FLOOR PLAN FOR ADDITIONAL NOTES.D. ALL DIMENSIONS ARE FROM FACE OF STUD FRAMING TO FACE OF STUD FRAMINGUNLESS OTHERWISE NOTED.E. SEE WALL TYPES, DOORS AND HARDWARE SCHEDULES FOR ADDITIONALINFORMATION.F. WHERE DISSIMILAR FLOOR MATERIALS MEET, THEY SHOULD DO SO UNDER THECENTERLINE OF THE DOOR, UNLESS OTHERWISE NOTED.G. SEE TYPICAL DETAILS FOR LOCATION OF HINGE SIDE OF DOOR JAMBS FROMADJACENT WALLS IN METAL STUD WALLS UNLESS OTHERWISE NOTED.H. PROVIDE BLOCKING IN NEW AND EXISTING WALLS FOR ALL WALL SUPPORTEDITEMS. SEE PLANS FOR CASEWORK LOCATIONS.I. ALL MATERIALS TO BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS ANDSTANDARD SPECIFICATIONS.J. REFER TO ROOM FINISH SCHEDULE FOR ALL REQUIRED FINISH INFORMATION.K. WHERE NEW WALL CONSTRUCTION IS REQUIRED ADJACENT TO OR ABUTTINGEXISTING CONSTRUCTION, ALIGN FACE OF NEW CONSTRUCTION WITH FACE OFEXISTING CONSTRUCTION. SKIM ENTIRE WALL SURFACE AS REQUIRED TO PROVIDESMOOTH, FLUSH TRANSITIONS.L. PROVIDE CONTROL JOINTS IN ALL RUNS OF GYPSUM BOARD. WALLS OVER 30 FEETIN LENGTH. COORDINATE WITH ARCHITECT PRIOR TO INSTALLATION FORCOMPLIANCE WITH DESIGN INTENT.M. PREP ALL WALL SURFACES TO RECEIVE NEW PAINT OR WALL COVERING FINISH.PATCH ALL EXISTING HOLES IN AREAS TO RECEIVE NEW FINISHES. SAND WALLSSMOOTH PRIOR TO PAINTING. PROVIDE BLANK COVER PLATES WHERE NEEDED.REMOVE EMERGENCY LIGHTS, SIGNAGE, THERMOSTATS, FIRE STROBES, ETC.PRIOR TO PAINTING AND REINSTALL WHEN COMPLETE.N. ALL PENETRATIONS IN AND THROUGH FIRE AND SMOKE RATED WALLS SHALL BESLEEVED AND FIRE STOPPED AS NECESSARY TO MAINTAIN RATINGS.O. SEE MEP DRAWINGS FOR RELATED LEGENDS AND SCOPE OF WORK.FLOOR PLAN NOTES1 REPAIR WALL AT AREA OF DEMOLITION. PREP FOR NEW FINISH.2 NEW CASEWORK, COOK TOP, & SINK BY OWNER. PROVIDE PLUMBING TO NEW SINKLOCATION.3 NEW WALL MOUNTED OVENS BY OWNER, SEE ELEVATION.4 NEW RECEPTION/DISPLAY BY OWNER.5 NEW BOOKSHELF BY OWNER.6 NEW TABLE BY OWNER.7 NEW DISHWASHER BY OWNER.8 NEW REFRIGERATOR BY OWNER.9 NEW WIRE SHELVING BY OWNER.10 RE-INSTALL RELOCATED BATHROOM ACCESSORIES AND MIRROR.11 RE-INSTALL RELOCATED TOILET & SINK.12 PROVIDE CLEAN & LEVEL SUFACE TO PREP FOR NEW FLOORING. NEW FLOORING TO BEINSTALLED ON TOP OF EXISTING FLOORING.13 REPAIR FLOOR IN AREA OF DEMOLITION TO PREP FOR NEW FLOORING INSTALL.15 NEW BRACKET MOUNTED FIRE EXTINGUISHER 1/4" = 1'-0"A100PROPOSED FLOOR PLAN4E 1/4" = 1'-0"A100REFLECTED CEILING PLAN1EGENERAL REFLECTED CEILING NOTESA. DIMENSIONS ON REFLECTED CEILING PLAN ARE TAKEN FINISHED FACE TOFINISHED FACE.B. SEE ELECTRICAL FOR SWITCHING OPERATION AND LOCATION.C. COORDINATE ALL DUCTWORK AND LIGHTING WITH STRUCTURE, BULKHEAD ANDCEILING TO DECK CLEARANCES PRIOR TO STARTING WORK.D. LIGHTS AND DIFFUSERS SHOWN FOR LOCATION. SEE ELECTRICAL AND HVACPLANS FOR FIXTURE COUNTS AND TYPES.E. UNLESS OTHERWISE NOTED/SHOWN - CENTER NEW GRID EACH DIRECTION INROOM. MAINTAIN MINIMUM EDGE TILE AT 6".F. UNLESS OTHERWISE NOTED/SHOWN - PLASTER / GYP. BOARD BULKHEAD SIDESAND UNDERNEATH TO BE PAINTED, PAINT TO BE GENERAL CEILING WHITE.REFLECTED CEILING PLAN NOTESC2 RELOCATED LIGHT FIXTURE.C3 RELOCATED SUPPLY OR RETURN DIFFUSERS.C5 NEW PENDANT LIGHT FIXTURE.C6 NEW DIRECTIONAL RECESSED LED LIGHT.C7 PROVIDE NEW CEILING TILE AT THIS LOCATION.C8 NEW WALL MOUNTED SCONCE MOUNTED AT 8'-0".REFLECTED CEILING PLAN LEGENDNOT TO SCALEKEY PLANNORTHRevision ScheduleRevision Number Revision Date Revision Description
ABCDE12345671234567ABCDEwww. studio3design.netPhone: (317) 595.1000Fax: (317) 572.12368604 Allisonville Road, Suite 330Indianapolis, IN 46250THIS DRAWINGS IS THE PROPERTYOF STUDIO 3 DESIGN, INC. ALLRIGHTS RESERVEDPROJECT NUMBER:DATE:CERTIFICATION:SHEET DESCRIPTION:SHEET NUMBER:1700617006170061700602-24-1702-24-1702-24-1702-24-17FINISH LEGEND &FINISH LEGEND &FINISH LEGEND &FINISH LEGEND &FFFFIIIINNNNIIIISSSSHHHH MMMMAAAATTTTEEEERRRRIIIIAAAALLLLSSSSA130A130A130A130SPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOL13190 HAZEL DELL PKWYCARMEL, IN 46033FINISH MATERIAL LISTMARK MANUFACTURER STYLE MODEL NUMBER COLOR SIZE COMMENTS HEADERCEILINGSCLG-12X2 TILEMATCH EXISTING LAY-IN CEILING TILE& GRIDCEILINGSGROUTG-1 TO BE SELECTED BY OWNERGROUTLUXURY VINYL PLANKLVP-1 CORETEC PLUSENGINEERED LOCKING 50LVP707BLACKSTONE OAK 7"X48"; 8 MMLUXURY VINYLPLANKPAINTP-1 SHERWIN WILLIAMSCEILING WHITELOCATION: CEILING TILE & GRIDPAINTP-2 SHERWIN WILLIAMSEGGSHELLTO BE SELECTED BY OWNERLOCATION: GENERAL WALL COLORPAINTP-3 SHERWIN WILLIAMSEGGSHELLTO BE SELECTED BY OWNERLOCATION: ACCENT COLORPAINTP-4 SHERWIN WILLIAMSSEMI-GLOSSTO BE SELECTED BY OWNERLOCATION: DOOR TRIMPAINTPLASTIC LAMINATEPL-1 TO BE SELECTED BY OWNERPLASTICLAMINATERESILIENT BASEB-1 TO BE SELECTED BY OWNERRESILIENTBASESOLID SURFACESS-1SOLIDSURFACETILET-1 TO BE SELECTED BY OWNERTILETRANSITION STRIPTS-1 TO BE SELECTED BY OWNERLOCATION: TRANSITION BETWEEN LVP-1 & EXISTING TILE; TRANSITION BETWEEN OFFICEFLOORING & EXISTING TILE.TRANSITIONSTRIPROOM FINISH SCHEDULENUMBER NAMEBASEFINISHWALLSCEILINGFINISHCOMMENTSNORTH SOUTH EAST WEST104 OFFICE B-1 P-2 P-2 P-2 P-2 P-1105 WORK ROOM B-1 P-2 P-2 P-2 P-2 P-1102 RELOCATED TOILET B-1 P-2 P-2 P-2 P-2 P-1 EPOXY PAINT AT THISLOCATION103 PREP AREA B-1 P-2 P-2 P-2 P-2 P-1100 CLASSROOM B-1 P-2 P-2 P-2 P-2 P-1Revision ScheduleRevision Number Revision Date Revision Description
A1TYPICAL 3-5/8" STUD WALL - NON-RATEDA 3-5/8" STUD WALL TO GRID3-5/8" STUD WALL TO GRID W/ SOUND BATTS.BASE AS SCHED.PLAN VIEWSUSPENDED CEILING- REFER TOREFLECTED CEILINGPLAN.3-5/8" STEEL STUDS@ 16" O.C.STEEL STUD RUNNERTRACK. STUDSSCREWED ON EA. SIDEAT BOTTOM.ONE LAYER 5/8"GYP. BD. EA. SIDE.FLOOR SLAB3" SOUNDATTENUATION BLANKET(S.A.B.) @A1ONLY)0' - 0 5/8"0' - 3 5/8"0' - 0 5/8"0' - 0 3/8"DECK0' - 4"3-5/8" STUD WALL - 1 SIDE GYP.BPLAN VIEW5/8" GYP. BD. ALLAPPLICATIONS.3 5/8" METAL STUDB10' - 3 5/8"0' - 0 5/8"INSULATION W/ VAPORBARRIER TO DECK @ EXTERIORWALL DECKINSULATION ONLYTO DECK0' - 4 7/8"B20' - 4"0' - 8"0' - 8"0' - 2"0' - 0 1/2"VARIES0' - 0 1/2"VARIESSINGLE TOP TRACKBETWEEN JAMB STUDS3-5/8" MTL. STUD w/ 5/8"GYP. BOARD EACH SIDESEALANT EACH SIDEHOLLOW METAL DOOR FRAMEDOOR AS SCHEDULED+7'-2" A.F.F.TOP OF FRAME0' - 2"0' - 0 1/2"VARIES0' - 0 1/2"VARIESSINGLE TOP TRACKBETWEEN JAMB STUDS3-5/8" MTL. STUD w/ 5/8"GYP. BOARD EACH SIDESEALANT EACH SIDEHOLLOW METAL DOOR FRAMEDOOR AS SCHEDULED+7'-2" A.F.F.TOP OF FRAMEAAAAFLUSHSCW7' - 0"3' - 0"ABCDE12345671234567ABCDEwww. studio3design.netPhone: (317) 595.1000Fax: (317) 572.12368604 Allisonville Road, Suite 330Indianapolis, IN 46250THIS DRAWINGS IS THE PROPERTYOF STUDIO 3 DESIGN, INC. ALLRIGHTS RESERVEDPROJECT NUMBER:DATE:CERTIFICATION:SHEET DESCRIPTION:SHEET NUMBER:1700617006170061700602-24-1702-24-1702-24-1702-24-17WALL TYPES &WALL TYPES &WALL TYPES &WALL TYPES &DETAILSDETAILSDETAILSDETAILSA150A150A150A150SPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOL13190 HAZEL DELL PKWYCARMEL, IN 46033 1 1/2" = 1'-0"A150WALL TYPES5E 3" = 1'-0"A150DOOR- JAMB DETAIL6C 3" = 1'-0"A150DOOR - HEAD DETAIL6B 1/4" = 1'-0"A150DOOR ELEVATION5BRevision ScheduleRevision Number Revision Date Revision Description
2' - 0"6' - 0"12' - 6"WALL SCONCESCENTER OVER OVENSPAINTED KID TRIM@ TOP OF TILEMICROWAVE/OVENAPPLIANCES - SIZEAND SPEC TO BEDETERMINED BYOWNER, TYP.WALL BASEWALL TILE BY OWNER.FULL TILES TOP TOBOTTOM ONLY.INSTALL (2) PENDANT LIGHTSOVER FRONT DESK.REJUVENATION HALEIGH WIREDOME RENDANT 8" ITEM#A5905 FINISH: POLISHEDNICKEL (VERIFY LENGTH)9' - 0"11' - 0"WALL SCONCES - LOKIESFURNITURE BY OWNER,PAINTED BY G.C.PLASTIC LAMINATE DISPLAYCASE BY OWNER.PAINTED 5.5" SHIP LAPWOOD PLANKS(8) ISLAND PENDANTS - RHHARMON PENDANTS19"X19" POLISHED NICKELWALL BASESIGNAGEABCDE12345671234567ABCDEwww. studio3design.netPhone: (317) 595.1000Fax: (317) 572.12368604 Allisonville Road, Suite 330Indianapolis, IN 46250THIS DRAWINGS IS THE PROPERTYOF STUDIO 3 DESIGN, INC. ALLRIGHTS RESERVEDPROJECT NUMBER:DATE:CERTIFICATION:SHEET DESCRIPTION:SHEET NUMBER:1700617006170061700602-24-1702-24-1702-24-1702-24-17INTERIORINTERIORINTERIORINTERIORELEVATIONSELEVATIONSELEVATIONSELEVATIONSA600A600A600A600SPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOL13190 HAZEL DELL PKWYCARMEL, IN 46033 1/2" = 1'-0"A600MICROWAVE & OVEN - ELEVATION5D 1/2" = 1'-0"A600DISPLAY WALL - ELEVATION2ERevision ScheduleRevision Number Revision Date Revision Description
PROJECT LOCATIONHAZEL DELL CORNERSHOPPING CENTERN3N3N1N2JJJJJ J J JJN6N4N4N4N4N5N5N5N5TTE4E4E2E2E3E3E1E1E1SSTEXISTING LIGHT SWITCHEXISTING QUAD WALL OUTLETEXISTING DUPLEX WALL OUTLETEXISTING DATA JACKNEW LIGHT SWITCHNEW QUAD WALL OUTLETNEW DUPLEX WALL OUTLETNEW DATA JACKTHERMOSTATSDEMO LIGHT SWITCHDEMO QUAD WALL OUTLETDEMO DUPLEX WALL OUTLETDEMO DATA JACKABCDE12345671234567ABCDEwww. studio3design.netPhone: (317) 595.1000Fax: (317) 572.12368604 Allisonville Road, Suite 330Indianapolis, IN 46250THIS DRAWINGS IS THE PROPERTYOF STUDIO 3 DESIGN, INC. ALLRIGHTS RESERVEDPROJECT NUMBER:DATE:CERTIFICATION:SHEET DESCRIPTION:SHEET NUMBER:1700617006170061700602-24-1702-24-1702-24-1702-24-17DDDDEEEEMMMMOOOOLLLLIIIITTTTIIIIOOOONNNN &&&& NNNNEEEEWWWWELECTRICAL PLANELECTRICAL PLANELECTRICAL PLANELECTRICAL PLANE100E100E100E100SPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOL13190 HAZEL DELL PKWYCARMEL, IN 46033NOT TO SCALEKEY PLANNORTH 1/4" = 1'-0"E100NEW ELECTRICAL PLAN4E 1/4" = 1'-0"E100DEMOLITION ELECTRICAL PLAN1EELECTRICAL LEGENDDEMO ELECTRICAL PLAN NOTESE1 REMOVE EXISTING QUAD OUTLET AT THIS LOCATION.E2 SALVAGE EXISTING THERMOSTAT AT THIS LOCATION. SAVE FOR RE-INSTALLATION.E3 REMOVE EXISTING SWITCH AT THIS LOCATION.E4 REMOVE EXISTING DUPLEX AT THIS LOCATION.NEW ELECTRICAL PLAN NOTESN1 EXISTING 225 AMP 208/120 3 PHASE PANEL.N2 INSTALL RELOCATED THERMOSTAT AT THIS LOCATION.N3 NEW SWITCH AT THIS LOCATION.N4 NEW JUNCTION BOX FOR ELECTRIC OVEN. VERIFY CIRCUIT SIZE WITH OVENMANUFACTURER.N5 NEW JUNCTION BOX FOR ELECTRIC COOKTOP. VERIFY CIRCUIT SIZE WITHMANUFACTURER.N6 PROVIDE ELECTRICAL CONNECTION AS REQUIRED FOR NEW DISHWASHER. VERIFYMODEL WITH OWNER.Revision ScheduleRevision Number Revision Date Revision Description
M3M3M2M1SABCDE12345671234567ABCDEwww. studio3design.netPhone: (317) 595.1000Fax: (317) 572.12368604 Allisonville Road, Suite 330Indianapolis, IN 46250THIS DRAWINGS IS THE PROPERTYOF STUDIO 3 DESIGN, INC. ALLRIGHTS RESERVEDPROJECT NUMBER:DATE:CERTIFICATION:SHEET DESCRIPTION:SHEET NUMBER:1700617006170061700602-24-1702-24-1702-24-1702-24-17NNNNEEEEWWWW MMMMEEEECCCCHHHHAAAANNNNIIIICCCCAAAALLLLPLANPLANPLANPLANM100M100M100M100SPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOL13190 HAZEL DELL PKWYCARMEL, IN 46033Revision ScheduleRevision Number Revision Date Revision Description 1/4" = 1'-0"M100NEW MECHANICAL PLAN4E1. CONTRACTOR SHALL PROVIDE MANUFACTURER'S RECOMMENDED ACCESS TO ALL MECHANICAL EQUIPMENTAND VALVES. COORDINATE LOCATION OF MECHANICAL EQUIPMENT WITH ITHER TRADES TO AVOID CONFLICT.2. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR LOCATION OF GRILLES AN DIFFUSERS.3. DRAWING IS DIAGRAMMATIC. PROVIDE ADDITIONAL OFFSETS, TRANSITIONS, ETC. AS REQUIRED TO AVOIDINTERFERENCE'S ENCOUNTERED.GENERAL NOTES:NEW MECHANICAL PLAN NOTESM1 RELOCATE EXISTING SUPPLY DIFFUSER TO AVOID CONFLICT WITH NEW LIGHT.M2 RELOCATE EXISTING EXHAUST FAN/LIGHT COMBO FROM EXISTING TOILETROOM TO NEW TOILET ROOM. PROVIDE NEW 4" DIA. EXHAUST DUCT TOOUTSIDE. PROVIDE WALL CAP WITH INSECT SCREEN. PROVIDE FLASHING ANDWEATHER TIGHT SEAL AROUND DUCT WHERE DUCTWORK PENETRATESEXTERIOR WALL.M3 PROVIDE NEW EXHAUST FAN WITH WALL SWITCH. SIZE FAN AS REQUIRED.COORDINATE SWITCH LOCATION WITH OWNER. PROVIDE NEW 4" DIA.EXHAUST DUCT AND CONNECT TO EXISTING WALL CAP.
EXIST.C.O.EXIST. 4"C.O.3"4"2"2"2"2"2"P1P3P4P5P5P5P5P2P63"NEW CONNECTION TOEXISTING SS. CONTRACTORTO FIELD VERIFY LOCATION.4" SANITARY SEWER LINE4"2"1 1/2"1 1/2"2"2"2"1 1/2"1 1/2"FLOORDRAINSINKSINKSINKSINKSINKW.C.1 1/2"2"3"3"DISH-WASHERCONNECT TOEXISTING VTRABCDE12345671234567ABCDEwww. studio3design.netPhone: (317) 595.1000Fax: (317) 572.12368604 Allisonville Road, Suite 330Indianapolis, IN 46250THIS DRAWINGS IS THE PROPERTYOF STUDIO 3 DESIGN, INC. ALLRIGHTS RESERVEDPROJECT NUMBER:DATE:CERTIFICATION:SHEET DESCRIPTION:SHEET NUMBER:1700617006170061700602-24-1702-24-1702-24-1702-24-17NEW PLUMBINGNEW PLUMBINGNEW PLUMBINGNEW PLUMBINGPLANPLANPLANPLANP100P100P100P100SPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOLSPROUTS COOKING SCHOOL13190 HAZEL DELL PKWYCARMEL, IN 46033Revision ScheduleRevision Number Revision Date Revision Description 1/4" = 1'-0"P100NEW PLUMBING PLAN4E1. THE WORK INCLUDES PROVIDING NEW MATERIALS, FITTINGS AND ACCESSORIES NECESSARY FOR ACOMPLETE FUNCTIONING PLUMBING SYSTEM. ALL WORK SHALL BE IN ACCORDANCE WITH LOCAL CODESAND/OR ORDINANCES AND IS SUBJECT TO INSPECTION. CONTRACTOR SHALL PAY HOOK-UP CHARGES,PERMITS, AND ALL OTHER EXPENSES RELATED TO THE PLUMBING SYSTEM.2. PROVIDE ALL DRAINS AND SEWERS WITHIN THE BUILDING WITH CONNECTION TO THE ON-SITE SANITARYDRAINAGE SYSTEMS. ALL DRAINAGE PIPING SHALL BE UNIFORMLY PITCHED, 1/4" PER FOOT UNLESSOTHERWISE REQUIRED BY EXISTING CONDITIONS, OR INDICATED ON THE DRAWINGS.3. PROVIDE CLEANOUTS AT ENDS OF EACH HORIZONTAL RUN, AND AT BASE OF ALL VERTICAL WASTE ANDDRAIN PIPES. CLEANOUTS SHALL BE SAME SIZE AS PIPES THEY SERVE, CONFORMING TO CODEREQUIREMENTS.4. HOT AND COLD WATER PIPING SHALL BE 1/2" MINIMUM, TYPE L COPPER TUBING WITH WROUGHT COPPERFITTINGS AND SWEAT CONNECTIONS. PROVIDE WATER HAMMER ARRESTERS AT EACH FIXTURE ORGROUP OF FIXTURES AS REQUIRED. INSTALL CHROME PLATED BRASS EXCUTCHEON PLATES AT ALLPENENTRATIONS THROUGH FINISHED SURFACES. USE TINANTIMONY SOLDER, 95/5 FOR ALL SWEATFITTINGS OF COPPER TUBING.GENERAL NOTES:NEW PLUMBING PLAN NOTESP1 NEW DISHWASHER, PROVIDED BY OWNER, INSTALLED BY PLUMBINGCONTRACTOR. VERIFY DRAIN SIZE WITH MODEL TYPE.P2 TIE INTO EXISTING SANITARY SYSTEM.P3 RELOCATED TOILETP4 RELOCATED SINKP5 NEW SINGLE BOWL SINK PROVIDED BY OWNER, INSTALLED BY PLUMBINGCONTRACTOR.P6 NEW CLEAN OUTNOT TO SCALEP100PLUMBING ISOMETRIC6E