HomeMy WebLinkAbout17030161 Building PlansTRAVEL DISTANCE = 62'-10"TRAVEL DISTANCE = 76'-4 1/2"W.H .TRAVEL DISTANCE = 50'-3 1/2"TRAVEL DISTANCE = 48'-11 1/2"ADJACENT TENANTADJACENT TENANTEXTERIOREXTERIOR COVERED WALKWAY DATEWRITTEN DIMENSIONS HOLD PREFERENCE OVERSCALED DIMENSIONS. DO NOT SCALE THEDRAWINGS. THE CONTRACTORS MUST VISIT JOBSITE TO VERIFY ALL EXISTING CONDITIONS ANDDIMENSIONS BEFORE SUBMITTING BIDS. REPORTANY DISCREPANCIES OF ANY CONDITIONS WHICHMAY INTERFERE WITH THE PROPER EXECUTIONOF, THE CONTRACT TO THE TENANT'SREPRESENTATIVE. REPORT DISCREPANCIESDURING BIDDING PROCESS AND BEFORE STARTOF CONSTRUCTION. CHANGE ORDERS WILL NOTBE APPROVED FOR ISSUES ARISING FROM THEFIELD CONDITIONS OR CONFLICTS BETWEEN THEPLANS AND THE EXISTING CONDITIONS.CONTRACTOR'S NOTES:ISSUEDATEREVISIONLOCATION:PROJECT INFORMATION:TITLE:SHEET NUMBER:ARCHITECTURAL SEAL:CONSULTANTS (ENGINEER):461 FROM ROADPARAMUS, NJ 07652973.253.9393 TEL973.253.9390 FAXWWW.SARGARCH.COM02/14/17ISSUE TO CLIENT,LL, HOMELANDSECURITYDATE: 02/14/17RANGELINE CROSSINGSHOPPING CENTER1356 S. RANGELINE RD.SPACE 1370CARMEL, IN 46032AREA: 2,988 SQ. FT.DRAWN BY: DTREVIEWED BY: ECBPROJECT NUMBER: 1621-1702/23/17LL COMMENTS02/23/17CLIENT / LLTITLE SHEETT-1.01.ALL WORK MUST CONFORM TO CODES, ORDINANCES AND REGULATIONS HAVING JURISDICTION OVER THE PROJECT.2.IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO FILE FOR PERMITS. NO WORK IS TO COMMENCE WITHOUT PROPER PERMITS. THIS INCLUDESALL TRADES, GENERAL CONSTRUCTION, MECHANICAL, PLUMBING, ELECTRICAL, SPRINKLER, ETC.3.CONTRACTOR(S) SHALL VERIFY ALL SITE DIMENSIONS ON ALL SITE CONDITIONS, EXISTING CONSTRUCTION GRADES AND UTILITIES ON PROJECT,AND CONTRACT DOCUMENTS AT PROJECT SITE PRIOR TO COMMENCING CONSTRUCTION. REPORT ALL DISCREPANCIES TO THE ARCHITECT ANDOWNER FOR CLARIFICATION BEFORE STARTING THE WORK.4.CONTRACTOR AND SUBCONTRACTOR ARE TO VERIFY ALL EXISTING AND NEW CONDITIONS ON THE JOB SITE PRIOR TO ORDERING, PURCHASING ORINSTALLING NEW FIXTURES, EQUIPMENT OR MATERIALS.5.CONTRACTOR(S) SHALL CONTACT LOCAL UTILITY COMPANIES FOR ANY INFORMATION ON UNDERGROUND OR HIDDEN CONDITIONS PRIOR TOCOMMENCING WITH ANY WORK. THE CONTRACTOR(S) SHALL BEAR ANY AND ALL EXPENSES FOR, AND SHALL REPAIR TO EXISTING CONDITIONS, ANYDAMAGE TO EXISTING UNDERGROUND OR HIDDEN UTILITIES, PIPING CONDUITS, EQUIPMENT, ETC. CALL 1-800-242-1776.6.ERRORS OR OMISSIONS IN ANY SCHEDULE OR ON ANY DRAWINGS DO NOT RELIEVE THE CONTRACTOR(S) FORM EXECUTING THE WORK INTENDEDON THE DRAWINGS OR DESCRIBED IN THE SPECIFICATION.7.THE CONTRACTOR AND SUBS SHALL WALK THE SITE INSIDE AND OUT TO PERFORM A SCOPE OF WORK INSPECTION, ANY AND ALL ADDITIONS ORCLARIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO SUBMITTING A BID, NO CHANGE ORDERS WILL BE PAID ONTHE BASE BID.8.THE CONTRACTOR(S) SHALL VERIFY THE SITE LOCATION, OPENINGS CHARACTERISTICS OF ALL WORK AND EQUIPMENT TO BE FURNISHED BY THEOWNER OR OTHERS, WITH THE MANUFACTURER OF SUPPLIER BEFORE STARTING ANY RELATED WORK TO SAID EQUIPMENT.9.NOTES ON DRAWINGS SHALL TAKE PRECEDENCE TO GENERAL NOTES, LARGE SCALE DETAILS AND SMALL SCALE DETAILS. DO NOT SCALEDRAWINGS. IN CASE OF ANY DISCREPANCY CONTACT THE ARCHITECT FOR CLARIFICATION PRIOR TO STARTING ANY WORK.10.ALL MANUFACTURERS LISTED ARE A STANDARD OF QUALITY. SUBSTITUTIONS WILL BE ACCEPTED. SUBSTITUTIONS MUST BE SUBMITTED FORAPPROVAL TO THE ARCHITECT AND THE OWNER PRIOR TO INSTALLATION. CONTRACTOR SHALL PAY ALL COSTS ANCILLARY TO A SUBSTITUTIONWHERE GRANTED. THIS INCLUDED COSTS INCURRED BY ANY CONTRACTOR OR SUBCONTRACTOR, THE OWNER, THE ARCHITECT, THE ENGINEERS,OR ANY OTHER PARTY. THIS INCLUDES COSTS RESULTING FROM DIFFERENCES OF DETAILS, CONFIGURATION, AND DIMENSION BETWEEN THESPECIFIED AND SUBSTITUTED EQUIPMENT. THIS INCLUDES COSTS TO PROVIDE FEATURES OF THE SPECIFIED EQUIPMENT WHICH MAY BEMANUFACTURER'S OPTIONS OF THE SUBSTITUTED EQUIPMENT.11.PRIOR TO COMMENCING WITH ANY PORTION OF THE WORK THE GENERAL CONTRACTOR SHALL PREPARE FLOOR/CEILING PLANS THAT WILLCOORDINATE ALL MATERIALS, OF ALL TRADES AND SUBCONTRACTORS. THE PLANS MUST INDICATE LOCATIONS OF SPRINKLER HEADS AND PIPING,HVAC UNITS AND EQUIPMENT CONDUIT, RISERS, ETC., SUSPENDED CEILING AND GRIDS, AND ANY OTHER ITEMS THAT MAY BE LOCATED IN THECEILING AREA. SUBMIT THE ABOVE TO THE ARCHITECT FOR APPROVAL.12.THE DRAWINGS AND/OR INTENT OF WORK TO BE PROVIDED, OF ALL TRADES AND SUBCONTRACTORS ARE TO BE CONSIDERED PART OF THECONTRACT DOCUMENTS. PRIOR TO COMMENCING WITH ANY WORK EACH INDIVIDUAL CONTRACTOR AND SUBCONTRACTOR SHALL REVIEW THEDRAWINGS OF ALL OTHER CONTRACTORS AND SUBCONTRACTORS (ALL TRADES) AND COORDINATE THEIR WORK WITHIN. SHOULD THERE BE ANYCONFLICT BETWEEN TRADES, CONTRACTORS OR SUBCONTRACTORS, IT SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND OWNERIMMEDIATELY, PRIOR TO COMMENCING WITH ANY WORK.13.ALL MATERIALS, FINISH AND COLOR SELECTIONS SHALL BE APPROVED BY THE OWNER PRIOR TO ANY INSTALLATION. CONTRACTOR(S) SHALLSUBMIT A MINIMUM OF (4) COPIES OF ALL SHOP DRAWINGS, PRODUCT LITERATURE, COLOR AND/OR MATERIAL SAMPLES TO THE ARCHITECT FORAPPROVAL. IN NO CASE SHALL A REPRODUCTION OF THE CONTRACT DOCUMENTS BE USED AS A SHOP DRAWING. ALL SHOP DRAWINGS ANDPRODUCT SPECIFICATIONS SUBMITTED MUST BEAR CONTRACTOR'S STAMP OF APPROVAL, WHICH INDICATES THAT HE HAS REVIEWED THEMATERIAL AND THEY ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS. SHOP DRAWINGS AND PRODUCT SPECIFICATIONS THAT DO NOT BEARTHE CONTRACTOR'S STAMP WILL NOT BE ACCEPTED.14.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND ALL SUBCONTRACTORS TO REMOVE ALL RUBBISH AND DEBRIS AND DISPOSE OFPROPERLY AND LEGALLY. THE SITE AND BUILDINGS MUST BE CLEANED ON A REGULAR BASIS.15.CONTRACTOR SHALL KEEP A COMPLETE UP TO DATE SET OF CONSTRUCTION DRAWINGS AND SHOP DRAWINGS OF ALL TRADES, WITH LATESTREVISIONS, ON SITE AT ALL TIMES.16.AS BUILT-DRAWINGS-CONTRACTOR TO KEEP A CLEAN, COMPLETE SET OF BLACK OR BLUE LINE PRINTS ON THE SITE. MARK SET IN RED ERASABLEPENCIL ALL CONCEALED ITEMS, CHANGES OR REVISIONS TO DRAWINGS DUE TO FIELD CONDITIONS,ANY INFORMATION NOT ORIGINALLY SHOWNAND/OR ADDED, AND ADDITIONS AND/OR REVISIONS DUE TO SHOP DRAWINGS. SUBMIT MARKED-UP SET TO OWNER AT THE COMPLETION OF THEPROJECT.17.WHERE REQUIRED BY CODE ALL WOOD BLOCKING, PLYWOOD, PARTICLE BOARD, WOOD PRODUCTS, ETC.-INTERIOR AND EXTERIOR SHALL MEETSMOKE AND FLAME SPREAD REQUIREMENTS OF FIRE RESISTIVE WOOD FOR NON-COMBUSTIBLE BUILDINGS OR SHALL BE FIRE RETARDANT WHEREREQUIRED BY CODE.18.ALL INTERIOR FINISHES SHALL MEET OR EXCEED FLAME SPREAD AND SMOKE DEVELOPMENT REQUIREMENTS AS REQUIRED BY APPLICABLE CODES.19.FURNITURE SHOWN IS FOR DESIGN INTENT ONLY. FURNITURE VENDOR IS RESPONSIBLE FOR FIELD DIMENSIONING & FIT VERIFICATION.20.ALL OPENINGS AND PENETRATIONS IN EXISTING DEMISING WALLS, ESPECIALLY ABOVE THE CEILING AND ALONG TOP OF WALL, TO BE FULLY SEALEDFOR ODORS. CONTRACTOR TO REMOVE CEILING TILES ALONG WALLS FOR INSPECTION BY LANDLORD REPRESENTATIVE.21.ANY REQUIRED ROOFING BY LANDLORD OR TENANT'S ROOFER TO BE APPROVED BY LANDLORD SO AS NOT EFFECT MANUFACTURES WARRANTY OFROOF.22.LOCATION OF CONSTRUCTION DUMPSTER TO BE APPROVED BY LANDLORD PRIOR TO PLACEMENT.23. TENANT'S G.C. TO CONTACT LL'S REP FOR PRECONSTRUCTION MEETING, LL'S REQUIRED ROOFER, DUMPSTER LOCATIONS AND CONTRCTORPARKING.DRAWING NUMBERDETAIL NUMBERDRAWING NUMBERELEVATION NUMBERDRAWING NUMBERSECTION NUMBERCOLUMN TAGPARTITION TYPEDOOR MARK-LANDLORDITEMEX'GDOESNOTAPPLYT.G.C.INSTALLFURNISHINSTALLDRAWING INDEX ARCHITECTURAL DRAWINGST-1.0A-1.0A-2.0A-3.0 MEP DRAWINGSM1.0M2.0M3.0E1.0E2.0E3.0FLOOR PLAN / WALL TYPES / DETAILSEXTERIOR ELEVATIONSMECHANICAL PLANMECHANICAL SPECIFICATIONSMECHANICAL DETAILSELECTRICAL POWER PLANELECTRICAL LIGHTING PLANELECTRICAL SCHEDULESSITE MAPGENERAL NOTESRESPONSIBILITY SCHEDULEABBREVIATIONSA-4.0DOG WASH STATION DETAILSE4.0ELECTRICAL SPECIFICATIONSREFLECTED CEILING PLANA-1.1SCHEDULES & DETAILSVESTIBULEGLAZING CHANNELS / ACCESSORIESGLAZINGDOOR HARDWAREDOORS AND FRAMES (TRIM)LIGHT GAUGE METAL FRAMINGGYPSUM WALL BOARDACOUSTICAL CEILINGRESILIENT FLOORINGVINYL BASETRANSITION STRIPSFIBERGLASS WALL PANELSPAINTINGSTOREFRONT SIGNAGETOILET ACCESSORIES (AS REQUIRED)FIRE PROTECTION SPECIALTIESSHELVES / HARDWARE AT DESKSPLUMBING SYSTEM - SEE 'P' SHEETSHVAC SYSTEM - SEE 'M' SHEETSAUTOMATIC SPRINKLER SYSTEMELECTRICAL SYSTEM - SEE 'E' SHEETSNOTES:1.TENANT RESPONSIBILITIES WILL BE INCLUDED IN THE GENERAL CONTRACTOR'S BID PACKAGE AND THE GENERAL CONTRACTOR IS REQUIRED TOPROVIDE A DETAILED BREAKDOWN ASSOCIATED WITH THESE COSTS.2.T.G.C. TO COORDINATE SUB-TRADE WORKING DRAWINGS AND PERMITS AS REQUIRED BY LOCAL AUTHORITIES, INCLUDING BUT NOT LIMITED TO:SPRINKLER, FIRE ALARM, ELECTRICAL, LOW VOLTAGE / DATA, MECHANICAL, PLUMBING, AND BACK OF HOUSE SHELVING PERMITS.SUMMARY OF WORKADDITIONS / ALTERNATIVESBUILDING PERMITSTEMPORARY FACILITIES / UTILITIESTEMPORARY BARRICADEPROJECT CLOSEOUTDEMOLITIONDUMPSTERCASHWRAPFLOOR FIXTURES (SALES AREA)PERIMETER WALL FIXTURES / SHELVESFIREPROOFING (AS REQUIRED)1.ALL POWER DATA AND DEVICES TO BE MOUNTED VERTICALLY AT18" A.F.F. UNLESS NOTED OTHERWISE.2.ALL DEVICES AND COVERPLATES TO BE OFF-MATCH EXISTING UNLESS NOTED OTHERWISE.3.ALL LOCATIONS TO BE REVIEWED AND APPROVED WITH THE TENANT PRIOR TO FINAL CLOSING OFPARTITIONS.TITLE SHEETFURNISHPROJECT CODE ANALYSISREMARKSLIGHTINGA.C.T.ACOUSTICAL CEILING TILEADJ.ADJACENTA.F.F.ABOVE FINISHED FLOORALUM. ALUMINUMAPPROX.APPROXIMATEBD.BOARDBLDG.BUILDINGCLR.CLEARC.M.U.CONCRETE MASONRY UNITCOL.COLUMNCONC.CONCRETEDIA.DIAMETERDTL.DETAILDWG.DRAWINGEA.EACHELEC.ELECTRICALELEV.ELEVATIONEQ.EWUALEX.EXISTINGEXT.EXTERIORF.E.FIRE EXTINGUISHERFIN.FINISHFLR.FLOORFT.FEETGA.GAUGEGALV.GALVANIZEDGYP. GYPSUMH.M.HOLLOW METALLOC.LOCATIONMAX.MAXIMUMMECH.MECHANICALMFR.MANUFACTURERMIN.MINIMUMM.O. MASONRY OPENINGMTD.MOUNTEDMTL.METALN.I.C.NOT IN CONTRACTNO.NUMBERO.C.ON CENTEROPP.OPPOSITEREQ'DREQUIREDREV.REVISIONRM.ROOMR.O.ROUGH OPENINGS.C.SOLID CORESCH.SCHEDULESIM.SIMILARSPEC.SPECIFICATIONSQ.SQUARESTL.STEELSTRUCT.STRUCTURETYP.TYPICALV..T.VINYL COMPOSITION TILEV.I.F.VERIFY IN FIELDW/WITHWD.WOODPROJECT DIRECTORYTENANTPET VALU489 DEVON PARK DRIVE - SUITE 320WAYNE, PA 19087CONTACT: MICHAEL POTTSPOSITION:PROJECT MANAGERPHONE: (267) 229-3453EMAIL:mpotts@petvalu.comTENANT'S ARCHITECTTENANT'S M.E.P. ENGINEERLANDLORDBUILDING DEPARTMENTVICINITY MAPEGRESS PLAN (N.T.S.)POWER AND COMMUNICATION NOTESDRAWING SYMBOLSKEYED NOTEROOF WORK1.PROJECT NAME:PET VALU2.PROJECT ADDRESS:RANGELINE CROSSING SHOPPING CENTER1356 S. RANGELINE ROADSPACE 1370CARMEL, IN 460323.PROJECT DESCRIPTION:RETAIL STORE4.APPLICABLE CODES:BUILDING2014 INDIANA BUILDING CODEPLUMBING2012 INDIANA PLUMBING CODEELECTRICAL2009 INDIANA ELECTRICAL CODEMECHANICAL2014 INDIANA MECHANICAL CODEFIRE2014 INDIANA FIRE CODELIFE SAFETY2014 INDIANA FIRE CODEACCESSIBILITY2012 IBC CH. 11/ 2003 ANSI A117.1ENERGY2010 INDIANA ENERGY CODETHE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODESAND MUST NOTIFY THE ARCHITECT OF ANY DISCREPANCIES INDICATED BY THESEDOCUMENTS FOUND, PRIOR TO OR DURING WORK, PRIOR TO PROCEEDING WITH THE WORK.5.BUILDING DATA:A. OCCUPANCYRETAILB. USE GROUPM-MERCANTILEC. CONSTRUCTION TYPEIIIBD. COVERED MALLNOE. SPRINKLEREDYESF. GROSS FLOOR AREA2,988 SQ. FT.6.SQUARE FOOTAGE CALCULATIONS: GROSS NETSALES AREA2,753SQ. FT.1,738SQ. FTTOILET ROOM 91SQ. FT. 72SQ. FTSPECIALTY AREA 144SQ. FT. 113SQ. FTTOTAL2,988 SQ. FT.1,923 SQ. FT.7.OCCUPANCY CALCULATIONS:SALES AREA (30 SQ. FT. NET/OCC.)58 OCCUPANTSTOILET ROOM (100 SQ. FT. NET/OCC.)01 OCCUPANTSSPECIALTY AREA - 2-BAY DOG WASH (60 SQ. FT. NET/OCC.)02 OCCUPANTSTOTAL 61 OCCUPANTS8.REQUIRED EXITS:TWO (2) EXITS REQUIRED, TWO (2) EXITS PROVIDED2,988 SQ. FT. / 30 OCC. LOAD = 99.6 OCC. LOAD99.6 X .2 = 19.92 LIN. IN / 12 = 1.66 LIN. FT.EXIT WIDTH REQUIRED:1.66 LIN. FT.EXIT WITH PROVIDED:(1) 3'-0" ENTRY(2) 3'-0" REAR EXIT9.EXIT ILLUMINATION:SHALL BE PROVIDED AS SHOWN ON DRAWINGS.10.LAVATORY:(1) REQUIRED(1) PROVIDED11.WATER CLOSET:(1) REQUIRED(1) PROVIDED12.DRINKING FOUNTAIN:(1) HI-LO(1) PROVIDED13.MOP SINK(1) REQUIRED(1) PROVIDEDPET VALURANGELINE CROSSINGSHOPPING CENTER1356 S. RANGELINE RD.SPACE 1370CARMEL, IN 46032petvalu STORE FIT-OUT RANGELINE CROSSING SHOPPING CENTER1356 S. RANGELINE ROADSPACE 1370CARMEL, IN 46032KITE REALTY GROUP30 SOUTH MERIDIAN STREET, SUITE1100INDIANAPOLIS, IN 46204CONTACT: SHAUNNA MARSHALLPHONE: (317) 577-5600FAX:(317) 577-7879MOBILE:(317) 3741232EMAIL:smarshall@kiterealty.comCITY OF CARMELONE CIVIC SQUARECARMEL, IN 46032CONTACT: NICK MISHLERPOSITION:BUILDING OFFICIALPHONE: (317) 571-2417EMAIL: nmishler@carmel.in.govA-5.0TOILET ROOM PLAN / ELEVATIONS / SCHEDULEEXTEND LINES AS NEEDED - SEE PLUMBING SHEETSSEE ELECTRICAL SHEETS FOR SCOPE OF WORKCOORDINATE WITH SIGN VENDORROOM NAME-ROOM TAGSUBMITTAL CLIENT / L.L. 02/14/17 REVISION #1 CLIENT / L.L. / HOMELAND SECURITY 02/23/17 FIRE ALARM SYSTEMSPRINKLER SYSTEM TO BE MODIFIED. G.C. TO SUBMITDRAWINGS UNDER SEPARATE SUBMITTALFIRE ALARM SYSTEM IS REQUIRED.VENDORS INFORMATIONMODULAR DOG WASH STATIONCUSTOM DESIGNING & ENGINEERING153 EAST MAIN STREETROCKAWAY, NJ 07866CONTACT: KENNETH A. FULLER, P.E.PHONE:(973) 784-4258EMAIL:kfuller@customdande.comMODULAR DOG WASHSTATION AAPEX CREATIONS INC. CONTACT: PAUL STEWART PHONE: (267) 932-8251 EMAIL: contact@aapex.us WWW.AAPEX.US TANKLESS GAS WATER HEATERCONTACT: ARUN MATHEWSPHONE: (630) 200-7310EMAIL: arunmathews@mytanklesswaterheaterstore.comG.C. TO PURCHASE THROUGH VENDOR AAPEXCREATIONS INC. DELIVERED & SETUP BY VENDORAAPEX CREATIONS INC. G.C. TO COORDINATE. G.C.TO DO FINAL ELECTRICAL CONNECTION, ROUGH-IN,AND FINAL PLUMBING CONNECTIONS.SARGENTI ARCHITECTS461 FROM ROAD - SECOND FLOORPARAMUS, NJ 07652CONTACT: NICOLE DE LUCAPOSITION:PROJECT MANAGERPHONE:(973) 253-9393 X126EMAIL:ndeluca@sargarch.comCONTACT: ELLEN BLAKELYPOSITION:SENIOR PROJECT MANAGERPHONE:(973) 253-9393 X137EMAIL:eblakely@sargarch.comP1.0P2.0PLUMBING WATER SUPPLY PLANPLUMBING SCHEDULESP3.0PLUMBING RISER DIAGRAMP1.1PLUMBING SANITARY PLANPET VALURANGELINE CROSSINGSHOPPING CENTER1356 S. RANGELINE RD.SPACE 1370CARMEL, IN 46032LIGHTINGREGENCY LIGHTINGPET VALU NATIONAL ACCOUNTCONTACT: CARMEN ALLENPHONE: 1-800-284-2024 X 3335E-MAIL: petvalu@regencylighting.comwww.regencylighting.com FLOORINGKARNDEAN CONTACT:JON TROSHYNSKIPHONE: (913) 201-2491EMAIL: jonathan.troshynski.comGREEN MOUNTAIN CONTACT:MICHAEL RANDAZZOPHONE: (201) 931-5216EMAIL: mrandazzo@greenmountainservices.net1LANDLORD NOTES1.IN EXISTING CENTERS, CONCRETE SAWCUTTING OR CORE DRILLING WILL BE PREFORMEDBEFORE AND AFTER CENTER HOURS OF OPERATION.2.PRIOR TO CONCRETE CUTTING OR BORING TENANT SHALL NOTIFY THE LANDLORD 'S REPOF WORK TO BE PERFORMED.3.IF THE TENANT SAWCUTS OR BORES THROUGH THE CONCRETE FLOOR, TENANT IS RESPONSIBLE TO RESTORE THE VAPOR BARRIER AT TENANT'S COST AND EXPENSE. LANDLORD WILL NOT BE RESPONSIBLE FOR TENANT FAILED FLOOR FINISH APPLICATIONIF TENANT NEGLECTS TO COMPLETE THIS REQUIREMENT.4.TENANT IS REQUIRED TO HAVE THE LANDLORD REVIEWED SET OF DRAWINGS ON SITEDURING THE CONSTRUCTION OF THE SPACE.5.TENANT SHALL CONSTRUCT THEIR SPACE IN ACCORDANCE TO THE LANDLORD REVIEWEDSET OF DRAWINGS AND THE PERMITTED SET OF DRAWINGS.6.DO NOT ATTACH ANY CONSTRUCTION TO THE ROOF DECK, JOIST BRIDGING, JOIST CROSS-BRACING, PIPING, CONDUIT, DUCTWORK OR ANY OTHER NON-STRUCTURAL ITEM.7.DO NOT WELD, DRILL, SHOOT OR SCREW INTO STRUCTURAL STEEL OR JOISTS. USE CLAMPS, TIE-WIRE, THRU-BOLTS WITH WASHERS, ETC.8.DO NOT USE ANY WOOD BLOCKING, PVC, PLASTIC, ETC. IN PLENUM OR DEMISING WALLS.1 3A-1.11A-4.01A-3.000193A-1.02A-3.0DIRECTION OF FLOORING4'-6"111514'-9"DIMENSION OF DOG WASHEXTERIOR 74'-3"LEASE LINE DIMENSION38'-5" LEASE LINE DIMENSION COVERED WALKWAY ADJACENT TENANTADJACENT TENANTEXTERIOR5'-4 3/4"LEASE LINEDIMENSION9'-11 3/4"LEASE LINE DIMENSION28'-7 1/2"LEASE LINE DIMENSION 47'-0"LEASE LINE DIMENSION32'-8"LEASE LINE DIMENSION4' x 24" (72"H)4' x 24" (72"H)4' x 24" (72"H)4' x 20" (54"H)4' x 20" (54"H)4' x 20" (54"H)3 Tier GondolaBed Rack Table Display TableDisplayW.H.STACKINGWASHER/DRYERDVRCABINET6' Overstock4' Overstock4' x 20" (84"H)FREEZER4' x 20" (84"H)4' x 20" (84"H)4' x 26" (84"H)4' x 12" (84"H)4' x 24" (84"H)4' x 16"SLATWALL Cubby UnitCubby Unit4' x 24" (84"H)4' x 24" (84"H)4' x 20" (84"H)4' x 20" SLATWALL 48" HIGH 4' x 20"SLATWALL48" HIGH4' x 20"SLATWALL48" HIGHMODULARDOG WASH002SALES AREA001UNISEXTOILET ROOM0031333311112210544768161400200300422341A-5.05'-0"5'-0"5'-2" 5'-7"5'-3"5'-2"4'-10" 4'-6"4'-0"15'-2"LOCATION OF CASHWARP7'-2" LOCATION OF CASHWARP 12113'-8"3'-8"5'-7"8'-4"9'-9"3'-10 1/2"3'-8"3'-8"3'-8"171818182P-1P-1P-1P-1P-2P-2P-2P-2P-2P-1P-2P-219202'-3 1/2"6'-4" NEW M.O.3'-0"TO BEDEMO'D213'-4"224'-2"113P-1METAL STUDRUNNER.METAL STUD RUNNERSET IN SEALANT3 5/8" x #20 GA METALSTUDS @ 16" O.C.FINISHED FLOOR(1) LAYER 5/8" GYP.BD. TODECK ABOVE.4 1/4"ACTUAL11 1/2"=1'-0"PARTITION AGAINST DEMISING WALLEXISTING WALL6"STANDARD PARTITION5/8" GYPSUM BOARD-BOTH SIDES3 5/8" x #20 GA METALSTUDS @ 16" O.C.1 1/2" SOUND ATTENUATIONBLANKETACTUALNOMINALMETAL STUD RUNNERFASTENED TO CONC. SLABW/ITH HILTI GAS DRIVENX-GN-3/4" FASTERS AT 6" O.C.1 1/2"=1'-0"5"4 7/8"V.I.F.2SALES AREATOILET ROOMNEW A.C.T.UNDERSIDE OFDECK.UNDERSIDE OF DECK.V.I.F.PLUMBING WALL1 1/2"=1'-0"3METAL STUDRUNNERMETAL STUD RUNNERSET IN SEALANT6" x #20 GA METALSTUDS @ 16" O.C.FINISHED FLOOR(1) LAYER 5/8"WATERPROOF GYP.BD.7 1/4"ACTUALTOILET ROOM8'-6"SALES AREA6"NEW A.C.T.SEE A-2.0FOR HEIGHTUNDERSIDE OF DECK. 1 2 3 4 5 6 7LEASE LINE.EXISTING DEMISING WALL TO REMAIN. PATCH, REPAIR,EXTEND GYP. BD. TO DECK ABOVE AS REQUIRED ANDPREPARE SURFACE TO RECEIVE TENANT'S NEW FINISHES.MAINTAIN ALL FIRE RATINGS AS REQUIRED.EXISTING STOREFRONT SYSTEM TO REMAIN. G.C. TO CLEANTO BRING TO "LIKE NEW" CONDITION PRIOR TO TENANTTURNOVER. REFER TO HARDWARE SCHEDULE FOR MOREINFORMATION.NEW FIRE EXTINGUISHER, TYP. FINAL LOCATIONS ANDQUANTITY TO BE DETERMINED BY FIRE MARSHAL.NEW HI / LO DRINKING FOUNTAIN. SEE PLUMBING SHEETSFOR MORE INFORMATION.NEW MOP SINK. SEE PLUMBING SHEETS FOR MOREINFORMATION.NEW WATER HEATER. SEE PLUMBING SHEETS FOR MOREINFORMATION.LOCATION OF ELECTRICAL PANEL. SEE ELECTRICALSHEETS FOR MORE INFORMATION.NEW CASHWRAP. SEE ELECTRICAL SHEETS FOR MOREINFORMATION.NEW 6" WIDE X 6" HIGH TOILET ROOM IDENTIFICATIONSIGNAGE REFER TO ACCESSIBLE SIGNAGE DETAIL ONSHEET A-1.1 FOR ADDITIONAL REQUIREMENTS. ALLSIGNAGE SHALL COMPLY WITH ICC A117.1-2009.NEW 6" WIDE FRONT-DOOR EXIT SIGNAGE. REFER TOACCESSIBLE SIGNAGE DETAIL ON SHEET A-1.1 FORADDITIONAL REQUIREMENTS. ALL SIGNAGE SHALL COMPLYWITH ICC A117.1-2009.NEW 6" WIDE FRONT-DOOR ENTRY SIGNAGE REFER TOACCESSIBLE SIGNAGE DETAIL ON SHEET A-1.1 FORADDITIONAL REQUIREMENTS. ALL SIGNAGE SHALL COMPLYWITH ICC A117.1-2009.NOT USED. 8 910131211EXISTING EXTERIOR CMUWALL(3) NEW 4" x 8" x 92" 4,000 PSIPRECAST CONC. LINTELS WITH (2) #4REBAR ONE AT TOP & BOTTOM.PAINT TO MATCH EXTEROR WALLNEW 6'-4" X 7'-4" PTD. HM FRAMEGROUTED SOLID.CAULK JOINT BETWEEN FRAME, LINTELAND CMU(ELEV +7'-4" )TOP OF M.O.1 3/4"AT END BEARING GROUT SOLID 2COURSES 24" LONG/WIDE AT EACHEND.3/4"3/4"PATCH & REPAIR EXISTINGFINISHES AS NEEDEDNEW MODULAR DOG WASH STATIONS PROVIDED BY G.C.THROUGH VENDOR, AND INSTALLED BY VENDOR. SEESHEET A-4.0, PLUMBING AND ELECTRICAL SHEETS FORMORE INFORMATION.G.C. TO INSTALL FLOORING PLANKS FRONT TO BACK.NEW ACCESSIBLE TOILET ROOM. REFER TO SHEET A-5.0AND PLUMBING SHEETS FOR MORE INFORMATION.LOCATION OF MURAL BY PET VALU - GC TO ENSURE NOITEMS ARE INSTALLED ON WALL AT DOGWASHG.C. TO PROVIDE FURRING STRIPS AND (1) LAYER OF 5/8"TYPE X GYPSUM BOARD TO DECK. MAINTAIN ALL FIRERATINGS AS REQUIRED.REFER TO SHEET A-3.0 FOR DOCK DETAILS. EXISTING TOREMAIN AND EXPANDED PER NEW CONFIGURATION.EXISTING CONDUIT TO REMAIN.G.C. TO REMOVE EXISTING REAR EXIT DOOR, FRAME, ANDHARDWARE.EXISTING CMU WALL TO BE REMOVED AS DIMENSIONED TOEXPAND DOOR OPENING. DIMENSION SHOWN IS FOR NEWM.O. AND DOES NOT INCLUDE NECESSARY DEMOLITIONFOR NEW LINTEL. SEE FLOOR PLAN FOR MOREINFORMATION.141516171819212220DATEWRITTEN DIMENSIONS HOLD PREFERENCE OVERSCALED DIMENSIONS. DO NOT SCALE THEDRAWINGS. THE CONTRACTORS MUST VISIT JOBSITE TO VERIFY ALL EXISTING CONDITIONS ANDDIMENSIONS BEFORE SUBMITTING BIDS. REPORTANY DISCREPANCIES OF ANY CONDITIONS WHICHMAY INTERFERE WITH THE PROPER EXECUTIONOF, THE CONTRACT TO THE TENANT'SREPRESENTATIVE. REPORT DISCREPANCIESDURING BIDDING PROCESS AND BEFORE STARTOF CONSTRUCTION. CHANGE ORDERS WILL NOTBE APPROVED FOR ISSUES ARISING FROM THEFIELD CONDITIONS OR CONFLICTS BETWEEN THEPLANS AND THE EXISTING CONDITIONS.CONTRACTOR'S NOTES:ISSUEDATEREVISIONLOCATION:PROJECT INFORMATION:TITLE:SHEET NUMBER:ARCHITECTURAL SEAL:CONSULTANTS (ENGINEER):461 FROM ROADPARAMUS, NJ 07652973.253.9393 TEL973.253.9390 FAXWWW.SARGARCH.COM02/14/17ISSUE TO CLIENT,LL, HOMELANDSECURITYDATE: 02/14/17RANGELINE CROSSINGSHOPPING CENTER1356 S. RANGELINE RD.SPACE 1370CARMEL, IN 46032AREA: 2,988 SQ. FT.DRAWN BY: DTREVIEWED BY: ECBPROJECT NUMBER: 1621-1702/23/17LL COMMENTS02/23/17CLIENT / LLFLOOR PLAN /WALL SECTIONS /DETAILSA-1.01FLOOR PLAN1/4" = 1'-0"FLOOR PLAN KEYED NOTES2WALL SECTION DETAILS1 1/2" = 1'-0"3DOOR HEADER DETAIL1" = 1'-0" 16" - 18"FLOOR MOUNTWATER CLOSETELEVATION36" MIN.12"MIN.WALL MOUNT VERTICALGRAB BAR1 1/2"G.B.33" MIN. 36" MAX. 40" MAX. B.O. REFLECTIVE SURFACE 18" MIN.CLAVATORY &MIRROR ELEVATION15"FLOOR MOUNT WATERCLOSET ELEVATION12"MAX.42" MIN.1 12" MIN.L1 1/2"G.B.39" - 41"LAVATORY SECTION34" MAX.DEPTH 6 1/2"48" MINMAXIMUM BOWL8" MIN.KNEECLR.9"MIN.17"-25"48" MIN.30" MIN.DRINKINGFOUNTAIN PLAN15" MIN.DRINKING FOUNTAINELEVATIONSPOUT HEIGHTLOW FOUNTAINLOW FOUNTAINDRINKINGFOUNTAIN PROFILE38" - 43"FOR STANDING8" MIN.KNEECLR.6"MAX TOECLR.SPOUTHEIGHTSANITARY NAPKINVENDOR4" PROJECTION48" MAX.48" MAX.15" MIN.18"MIN.LIGHTSWITCHTOILETPAPERDISPENSERSOAPDISPENSER48" MAX.17" MIN 25" MAX SURFACE MTD.TOILET PAPER DISP.SHALL PERMITCONTINUOUSPAPER FLOWHAND OPERATEDWRIST BLADESTYLE FAUCETALL EXPOSEDPIPING TO BEINSULATEDMAXIMUM BOWLDEPTH 11"11"MIN. CLR.27" MIN.KNEE CLR.9"MIN.38" MAX.WHEELCHAIR ACCESS 15" MIN.5" MAX.5" MAX.36" MAX.WHEELCHAIRACCESS38" - 43"FOR STANDING 17" - 19" T.O. SEAT 39" - 41" 33" - 36" 18"24" MIN.24" MIN.27" MIN.KNEE CLR.6"MAX TOECLR.11"MIN. CLR.42" MAX.DUPLEXRECEPTACLELAVATORY PLAN30" MIN.ACCESSIBLE SIGNAGE REQUIREMENTS:1. PICTOGRAMS SHALL HAVE A FIELD HEIGHT OF 6" MINIMUM. THE PICTOGRAM SHALLCONTRAST WITH THE FIELD (LIGHT PICTOGRAM ON DARK FIELD OR DARK PICTOGRAMON LIGHT FIELD). CHARACTERS AND BRAILLE SHALL NOT BE LOCATED IN THEPICTOGRAM FIELD. THE CHARACTERS AND FIELD SHALL HAVE A NON-GLARE FINISH.2. PICTOGRAMS SHALL BE ACCOMPANIED BY THE EQUIVALENT VERBAL DESCRIPTIONPLACED DIRECTLY BELOW PICTOGRAM.3. LETTERS AND NUMERALS MUST BE RAISED 1/32" MINIMUM FROM SIGN SURFACE.4. CHARACTER HEIGHT MUST BE AT LEAST 5/8".5. TYPE STYLE FOR LETTERS AND NUMBERS SHALL BE CONVENTIONAL IN FORM, THEYSHALL NOT BE ITALIC, OBLIQUE, SCRIPT, DECORATIVE OR OF OTHER UNUSUAL FORMS.6. WORDS AND NUMBERS MUST BE CONVERTED INTO GRADE 2 BRAILLE (DOMED ORROUNDED) AND SHALL BE BELOW THE CORRESPONDING TEXT. BRAILLE SHALL BE 48"MINIMUM AND 60" MAXIMUM ABOVE THE FLOOR (MEASURED TO THE BASELINE OF THEBRAILLE).7. RAISED CHARACTERS SHALL BE 48" MINIMUM ABOVE THE FLOOR FLOOR TO THELOWEST RAISED CHARACTER AND 60" MAXIMUM TO THE HIGHEST RAISED CHARACTER.8. THE SIGN SHALL BE ALONGSIDE THE DOOR AT THE LATCH SIDE. WHERE THE SIGN ISPROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ONTHE INACTIVE LEAF. WHERE THE SIGN IS PROVIDED AT DOUBLE DOORS WITH TWOACTIVE LEAFS, THE SIGN SHALL BE TO THE RIGHT OF THE RIGHT-HAND DOOR. WHERETHERE IS NO WALL SPACE ON THE LATCH SIDE OF A SINGLE DOOR, OR THE RIGHT SIDEOF DOUBLE DOORS, SIGNS SHALL BE ON THE NEAREST ADJACENT WALL.9. SIGNS SHALL BE LOCATED SO THAT A CLEAR FLOOR AREA 18" MINIMUM BY 18" MINIMUM,CENTERED ON THE RAISED CHARACTERS IS PROVIDED BEYOND THE ARC OF ANY DOORSWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION.(ACCESSIBLE ENTRANCE / EXIT SIGNAGE)6"6"6"RAISED BRAILLE ATBOTTOM OF SIGN.WHITE LETTERS AND FIGUREON BLUE FIELD W/ NONGLARE FINISH.(ACCESSIBLE RESTROOM SIGNAGE)6"6"6"6"6"6"RAISED BRAILLE ATBOTTOM OF SIGN.WHITE LETTERS AND FIGUREON BLUE FIELD W/ NONGLARE FINISH.OPENAB18342212221218341834221277819581/4LOCKS DRAWERDOORSC3212Ø222332254141141/4C28185Ø22233ABDOORGROMMETHOLE, TYP.BOTH SIDES1/4" REVEAL1/2" DRAWERBOXGROMMETHOLE AT EACHDIVIDERGROMMETHOLEGROMMETHOLE1/4"REVEALDATEWRITTEN DIMENSIONS HOLD PREFERENCE OVERSCALED DIMENSIONS. DO NOT SCALE THEDRAWINGS. THE CONTRACTORS MUST VISIT JOBSITE TO VERIFY ALL EXISTING CONDITIONS ANDDIMENSIONS BEFORE SUBMITTING BIDS. REPORTANY DISCREPANCIES OF ANY CONDITIONS WHICHMAY INTERFERE WITH THE PROPER EXECUTIONOF, THE CONTRACT TO THE TENANT'SREPRESENTATIVE. REPORT DISCREPANCIESDURING BIDDING PROCESS AND BEFORE STARTOF CONSTRUCTION. CHANGE ORDERS WILL NOTBE APPROVED FOR ISSUES ARISING FROM THEFIELD CONDITIONS OR CONFLICTS BETWEEN THEPLANS AND THE EXISTING CONDITIONS.CONTRACTOR'S NOTES:ISSUEDATEREVISIONLOCATION:PROJECT INFORMATION:TITLE:SHEET NUMBER:ARCHITECTURAL SEAL:CONSULTANTS (ENGINEER):461 FROM ROADPARAMUS, NJ 07652973.253.9393 TEL973.253.9390 FAXWWW.SARGARCH.COM02/14/17ISSUE TO CLIENT,LL, HOMELANDSECURITYDATE: 02/14/17RANGELINE CROSSINGSHOPPING CENTER1356 S. RANGELINE RD.SPACE 1370CARMEL, IN 46032AREA: 2,988 SQ. FT.DRAWN BY: DTREVIEWED BY: ECBPROJECT NUMBER: 1621-1702/23/17LL COMMENTS02/23/17CLIENT / LLSCHEDULES& DETAILSA-1.11ACCESSIBILITY SIGNAGE DETAILS1/4" = 1'-0"2ACCESSIBILITY REQUIREMENTS AND MOUNTING HEIGHTSN.T.S.EXISTINGENTRYB1-ALUMALUM. &GLASS-4DOOR SCHEDULEFRAME TYPES12"2"H.M. STEELFRAMEHINGESLEVER LATCH SET, PRIVACY LOCK (PUSH BUTTON LOCK),SCHLAGE #S40D, NEPTUNE DESIGN. 626 FINISH, OR EQUALCLOSER NORTON #1600BCSILENCERS IVES #SR64-GRAYDOOR STOP - FLR. MTD. IVES MODEL # 204735HARDWARE SET 1: (TOILET ROOMS/ STORAGE ROOM)1 1/2 PR1111HINGES PER LEAFSTANLEY EXIT DEVICE/PANIC - APEX 2200CLOSER NEPTUNE#1600BCSILENCERS IVES #FB256-4 US26DFLUSH BOLTS FOR INACT. LEAF. - IVES # FB256NDOOR STOP - KICK DOWN HOLDER - IVES #FS4523/16" High STEEL THRESHOLD - Stainless or Primed and PaintedGray colorHARDWARE SET 3: (LOADING)1 1/2 PR116121NOTE:DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES,THE TIME REQUIRED TO MOVE THE DOOR TO AN OPEN POSITION OF 12 DEGREES SHALL BE5 SECONDS MINIMUM.DOOR FRAME & TYPESHARDWARE LEGENDHINGES AS PROVIDED BY ENTRY DOOR MANUF.CLOSER: LCN 440 OR EQUIVALENTWEATHER STRIPPINGBOTTOM DOOR SWEEPS THRESHOLDKICK-DOWN HOLDER IVES #FS452-4 US26D FINISH OR SIMILARLOCK MORTISE CYLINDER3/16" High STEEL THRESHOLD - Stainless or Primed and PaintedGray colorHARDWARE SET 4: (ENTRY)22211ROOM NAMEFLOORNO.BASEWALLSCEILINGNOTESFINISH SCHEDULEFINISH NOTES:DOOR NUMBERMAINTAIN ALL ADACLEARANCES3'-0" NEWDOOR12"MIN18"MINEXISTING DOORNOTES:CONTRACTOR TO VERIFYALL HARDWARE FUNCTION,KEYING AND SECURITYREQUIREMENTS WITHTENANT PRIOR TOPURCHASE.TO REMAINDOOR LEGENDALUM.= ALUMINUMGL.= GLASSH.M.= HOLLOW METALMTL= METALWD= WOODDOOR ABBREVIATIONS001002DOG WASH3'-0"3'-6"1-3/4"----SEE SHEET A-4.0 FOR MORE INFORMATION-MTLPTD003UNISEXTOILET ROOM004NEWREAR EXIT(2) 3'-0"7'-0"1-3/4"11PTDH.M.CMTLPTD33'-0"7'-0"1-3/4"ADOOR TYPES2" THK X 8" WWOOD LEDGEBCDDOORFRAMEHRDWRNO.WHTHKTYPEMATERIALFINISHTYPEMAT'LFINISHSET NO.NOTESOPENOPENSTANDARDBLACKVINYL COVEBASEVINYL PLANKVAN GOGHVGW41T "MERBAU"BY KARNDEANSALES001002MODULARDOG WASHTRIM COLOR: SW6258 TRICORN BLACK SEMI GLOSS FINISHFLOOR: STANDARD - ASTM C1028 ADA COMPLIANT : DRY 0.68, WET 0.66 PROVIDED / INSTALLED BY VENDORCEILING: PAINT PER FINISH NOTE #5WALLS: REFER TO FINISH NOTE #312X12 FRANCISCAN SLATE"TERRAIN MARRONE" FS98PROVIDED /INSTALLED BYVENDORBULL NOSE TILE: FRANCISCAN SLATE "TERRAIN MARRONE" P-43C92X2 MOSAIC TILE: HEATHLAND "SUNSET BLEND" HL08GROUT: CUSTOM BUILDING PRODUCTS FUSION PRO SINGLE COMPONENT GROUT IN #122 "LINEN"FRP: MARLITE #P106 "BEIGE"CEILING: PAINT PER FINISH NOTE #5WALLS: SALES AREA SIDE OF DOG WASH WALLS TO RECEIVE PAINT BENJAMIN MOORE - 1083 BEACH HOUSE BEIGEVINYL PLANKVAN GOGHVGW41T "MERBAU"BY KARNDEANSTANDARDBLACKVINYL COVEBASESIDE:BENJAMIN MOORE1083 BEACH HOUSE BEIGEFRONT AND BACK:SHERWIN WILLIAMSSW7598 SIERRA REDWOODP-1P-2NEWTOILETROOM003VINYL PLANKVAN GOGHVGW41T "MERBAU"BY KARNDEANSTANDARDBLACKVINYL COVEBASE3'-0"7'-0"1-3/4"1PTDH.M.AWDPTDXXXFLOOR: STANDARD - ASTM C1028 ADA COMPLIANT : DRY 0.68, WET 0.66NEW TOILET ROOM WALLS : FRP: MARLITE #P106"BEIGE". & PROVIDE SILICONE SEALANT JOINT ATTOP OF COVE BASE & FRP (TYP) UP TO 4'-O A.F.F.INTERIOR:BENJAMIN MOORE1083 BEACH HOUSE BEIGEP-1NEWACT1. VINYL, WALL BASE AND PAINT COLORS TO BE SELECTED AND VERIFIED BY TENANT.2. ALL DOORS TO BE PAINTED TO MATCH ADJACENT WALL COLOR - PAINT WITH SEMI-GLOSS FINISH. DOOR FRAMES TO BE PAINTED FLAT BLACK . PAINT IS SHERWIN WILLIAMSSW6258 'TRICORN BLACK' USING SHERWIN WILLIAMS DURATION PAINT IN SEMI-GLOSS FINISH.3. ALL DRYWALL WALLS TO UNDERSIDE OF DECK TO BE FINISHED AND PAINTED WITH PRIMER COAT AND MINIMUM OF THREE COATS OF SHERWIN WILLIAMS PROMAR 200 ZEROVOC IN EGGSHELL FINISH. WALLS TO BE PAINTED THEIR RESPECTIVE COLOR UP TO 11'-0" A.F.F. WALLS TO BE PAINTED BLACK FROM 11'-0" A.F.F. UP TO DECK ABOVE . PAINT ISSHERWIN WILLIAMS WATERBORNE ACRYLIC DRYFALL FLAT BLACK.4.WHEN APPLICABLE, GROOMING ROOM TO HAVE FRP TO 8'-0" AFF5. CEILING FINISHES:EXPOSED CEILING (BEAMS, HVAC, WIRING, ETC) TO BE PAINTED IN FLAT BLACK. PAINT #SW6258 SHERWIN WILLIAMS WATERBORNE ACRYLIC DRYFALL FLAT BLACK.EXISTING A.C.T. CEILING: EXISTING TILES TO BE PAINTED USING SHERWIN WILLIAMS PROMAR 400 FLAT, TINTED 85% TO BENJAMIN MOORE # 1083 BEACH HOUSE BEIGE. TILES MUSTBE REMOVED FOR PAINTING.OPTIONALLY, FINE FISSURED TILES BY EITHER CERTAINTEED IN 'WET CLAY' OR USG IN 'SANDSTONE' MAY BE USED INSTEAD OF PAINTING.GRID TO STAY WHITE OR TO BE REPAINTED WHITE IF DISCOLORED/ STAINED/RUSTED. IF GRID IS PAINTED, PAINT SHOULD BE APPROPRIATE FOR USE ON METAL. LATEX PAINTSHOULD NOT BE USED.NEW A.C.T. CEILING:NEW 2'X4' ACOUSTICAL LAY-IN SUSPENDED TYPE CEILING. TILES TO BE PRE-COLORED 2'X4' FINE FISSURED TILES BY EITHER CERTAINTEED IN 'WET CLAY' OR USG IN 'SANDSTONE'.GRID TO BE LEFT WHITE.6. DIRECTION OF VINYL PLANK FLOORING TO BE INSTALLED FRONT TO BACK.7. ALL COLUMNS TO BE PAINTED BLACK. PAINT IS SHERWIN WILLIAMS SW6258 'TRICORN BLACK' USING SHERWIN WILLIAMS DURATION PAINT IN SEMI-GLOSS FINISH.8. FLOORING NOTE:FLOOR IS TO BE MOISTURE TESTED PER ASTM-F2170 RELATIVE HUMIDITY (RH) TO MEET KARNDEAN INTERNATIONAL, VAN GOGH VGW41T MERBAU” VINYL PLANKS SPECIFICATIONSFOR DIRECT GLUE APPLICATION.A COPY OF THE MOISTURE TEST RESULTS SHALL BE PROVIDED TO THE TENANT, KARNDEAN REPRESENTATIVE, AND GREEN MOUNTAIN REPRESENTATIVE PRIOR TO FLOORINGINSTALLATION.KARNDEAN CONTACT: JON TROSHYNSKI – (913)-201-2491 JONATHAN.TROSHYNSKI@KARNDEAN.COMGREEN MOUNTAIN CONTACT: MICHAEL RANDAZZO - (201)-931-5216 MRANDAZZO@GREENMOUNTAINSERVICES.NETUNDERCUT DOOR 1" FOR TRANSFER AIRHINGESSTOREROOM LEVER LATCH SETSCHLAGE S80PD, NEPTUNE DESIGN. 626 FINISH, OR EQUALCLOSER NEPTUNE#1600BCSILENCERS IVES #FB256-4 US26DDOOR STOP - KICK DOWN HOLDER - IVES #FS452SLIDE SURFACE DOOR BOLTHARDWARE SET 2: (GROOMING ROOM)2 PR111113CASHWRAP DETAIL1/2" = 1'-0"G.C. TO ENSURE IN PROPER WORKING ORDER AND REPLACEHARDWARE AS NEEDED. MISC.HEIGHTACTROOM0038'-0"NEW2910MISC.HEIGHTOPENROOM001/0021FRONTEXTERIOR 74'-3"LEASE LINE DIMENSION38'-5" LEASE LINE DIMENSION COVERED WALKWAY ADJACENT TENANTADJACENT TENANTEXTERIOR5'-4 3/4"LEASE LINEDIMENSION9'-11 3/4"LEASE LINE DIMENSION28'-7 1/2"LEASE LINE DIMENSION 47'-0"LEASE LINE DIMENSION32'-8"LEASE LINE DIMENSIONEM/NLA2AAEM/NLAADX1X1DSEM/NL AAEM/NLAAAEM/NLAAAEM/NLAAAAAAAEM/NLAAAEM/NLAAAEM/NLAASSS30'-3" (TRACK LENGTH) 3'-6"69'-0"(TRACK LENGTH)3'-6"74'-6"(TRACK LENGTH)3'-6"1'-6" 5'-0"9'-1"9'-1"9'-1"5'-0" EQ.EQ.EQ.EQ.EQ.EQ.EQ.EQ.5'-9 1/2"2'-2"10'-4"11'-0"8'-0"11'-0"11'-0"11'-0"11'-0"6'-1"EQ.EQ.EQ.EQ.EQ.EQ.EQ.EQ.111334444555811111213121315'-2 1/2"1116666147 1 2LEASE LINE.LOCATION OF R.T.U. SEE MECHANICAL DRAWINGS FOR MOREINFORMATION.HIGH BAY LIGHTS TO BE INSTALLED AT 11'-0" A.F.F. SEE ELEC.DRAWINGS FOR MORE INFORMATION (TYP.).SPEAKERS. SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION(TYP.).TRACK LIGHTS TO BE INSTALLED AT 11'-0" A.F.F. ( TYP.). SEEELECTRICAL DRAWINGS FOR MORE INFORMATION.DIFFUSERS TO BE INSTALLED IN DUCTWORK. SEE MECHANICALDRAWINGS FOR MORE INFORMATION.COORDINATE LOCATION OF RETURN WITH MECHANICAL DRAWING.NEW 2'X4' FLUORESCENT LIGHT FIXTURE. SEE ELECTRICAL SHEETSFOR MORE INFORMATION.G.C. TO PAINT ALL EXPOSED BEAMS, HVAC, PIPE, WIRING, DECK ANDWALLS. WALLS TO BE PAINTED THEIR RESPECTIVE COLOR UP TO11'-0" A.F.F. WALLS TO BE PAINTED BLACK FROM 11'-0" A.F.F. UP TODECK ABOVE . PAINT IS SHERWIN WILLIAMS WATERBORNE ACRYLICDRYFALL FLAT BLACK.NEW 2'X4' A.C.T. IN TOILET ROOM.NEW EXHAUST FAN.NEW EMERGENCY EXIT LIGHTS. SEE FIXTURE SCHEDULE FOR MOREINFORMATION.NEW EXTERIOR SECURITY LIGHT. SEE FIXTURE SCHEDULE FORMORE INFORMATION.DIFFUSER MOUNTED IN CEILING GRID. SEE MECHANICAL SHEETSFOR MORE INFORMATION.345 6 7891011121314REFLECTEDCEILING PLANA-2.01REFLECTED CEILING PLAN1/4" = 1'-0"TYPEMANUFACTURERMODELDESCRIPTIONLAMPVOLTAGEMOUNTINGSYMBOLFIXTUREWATT.LAMPWATT.LIGHT FIXTURE SCHEDULENOTE: NO SUBSTITUTIONS ARE ALLOWED FOR FIXTURES 'A' AND 'A3'. ANY OTHER LIGHTING SUBSTITUTIONS TO BE APPROVED BY PET VALU.(E) EXISTING(RE) RELOCATED (NL) FIXTURE CONNECTED TO NIGHT LIGHT CIRCUIT.(EM) FIXTURE WITH EMERGENCY BATTERY BACK-UP.LITHONIA LIGHTINGSUSPENDED @ 11'-0"A.F.F. TO BOTTOM OFFIXTURE THROUGHOUTSALES AREA (UNLESSNOTED OTHERWISE).97LED120-15" WIDE X 25" LONG STANDARDEFFICIENCY LIGHT FIXTURE WITH ASEMI-DIFFUSE POLYCARBONATELENS AND STANDARD DISTRIBUTION.CORD TO BE BLACK.ACOLORBLACKLITHONIA LIGHTINGA-EM15" WIDE X 25" LONG STANDARDEFFICIENCY LIGHT FIXTURE WITHWITH EMERGENCY BATTERY PACK,A SEMI-DIFFUSE POLYCARBONATELENS AND STANDARD DISTRIBUTION.CORD TO BE BLACK.AEM/NLAA2A2LITHONIA LIGHTING2SP5-G-2-54T5HO-A12-MVOLT-GEB10PS24" WIDE X 48" LONG 2-LAMPFLUORESCENT LIGHTING.(2-LAMPS)FP54/850/HO/ECO[20949]WHITEGRID MOUNTED ATTOILET ROOM.EM/NLA2A2-EMLITHONIA LIGHTING24" WIDE X 48" LONG 2-LAMPFLUORESCENT LIGHTING.WHITEGRID MOUNTED ATTOILET ROOM.SUSPENDED @ 11'-0"A.F.F. TO BOTTOM OFFIXTURE THROUGHOUTSALES AREA (UNLESSNOTED OTHERWISE).CC-TRACKCONTECH LIGHTINGDDX1X1(EM)LITHONIA LIGHTINGLITHONIA LIGHTING108120/27754120/277TRACK: LT-2/4/6/8-BTRACK HEAD: CTL-601-BBLACK "H" STYLE TRACK WITHTRACK LIGHTING HEAD.BLACK(1- LAMP PERTRACK HEAD )TCPLED12BR30D50K-12012SUSPENDED @ 11'-0"A.F.F. TO BOTTOM OFTRACK THROUGHOUTSALES AREA (UNLESSNOTED OTHERWISE).LHQM-LED-R-HO-M6EMERGENCY EXIT COMBINATIONWITH TWIN LAMP EMERGENCYLIGHTING.ELA-T-QWP-L0309-M12TWIN LAMP EMERGENCY LIGHT3W31.5W1.5SURFACE MOUNTED.SURFACE MOUNTED.1201202SP5-G-2-54T5HO-A12-MVOLT-GEB10PS-EL14(2-LAMPS)FP54/850/HO/ECO[20949]10854GREY(LED ) (LED )WHITEBLACKLED120PET VALU NATIONAL ACCOUNT REPRESENTATIVE - CARMEN ALLENTEL: 1-800-284-2024 X 3335 Email: petvalu@regencylighting.com www.regencylighting.com97-IBG 15000LM SEF PFL GND120 OZ10 50K 80CRI CS1BLDBLIBG 15000LM SEF PFL GND120 OZ10 50K 80CRI PS10250CS93BL BPK DBLREFLECTED CEILING PLAN KEYED NOTESNOTES:1.IF FIRE ALARM AND SPRINKLER DRAWINGS ARE REQUIRED, G.C. TO SUBMIT UNDER SEPARATESUBMITTAL. SEE RESPONSIBILITY SCHEDULE ONSHEET T-1.0 FOR REQUIREMENTS. WALLMOUNTED FIRE ALARM DEVICES TO BECOORDINATED AROUND RACKING. ALLPERIMETER WALL FIXTURES ARE 7'-0" HIGH,UNLESS NOTED OTHERWISE.2. NO CONSTRUCTION TO BE ATTACHED TO THEROOF DECK. JOIST BRIDGING, JOIST CROSSBRACING, PIPING, CONDUIT DUCTWORK OR ANYOTHER NON-STRUCTURAL ITEM.RCP LEGENDGYPSUM BOARD CEILINGACT-1 - 2' X 4' ACOUSTICAL LAY-INSUSPENDED TYPE CEILING. TILESTO BE PRE-COLORED 2'X4' FINEFISSURED TILES BY EITHERCERTAINTEED IN 'WET CLAY' ORUSG IN 'SANDSTONE'.CEILING TYPESSSPEAKERDIFFUSERRETURNEXHAUST FANDATEWRITTEN DIMENSIONS HOLD PREFERENCE OVERSCALED DIMENSIONS. DO NOT SCALE THEDRAWINGS. THE CONTRACTORS MUST VISIT JOBSITE TO VERIFY ALL EXISTING CONDITIONS ANDDIMENSIONS BEFORE SUBMITTING BIDS. REPORTANY DISCREPANCIES OF ANY CONDITIONS WHICHMAY INTERFERE WITH THE PROPER EXECUTIONOF, THE CONTRACT TO THE TENANT'SREPRESENTATIVE. REPORT DISCREPANCIESDURING BIDDING PROCESS AND BEFORE STARTOF CONSTRUCTION. CHANGE ORDERS WILL NOTBE APPROVED FOR ISSUES ARISING FROM THEFIELD CONDITIONS OR CONFLICTS BETWEEN THEPLANS AND THE EXISTING CONDITIONS.CONTRACTOR'S NOTES:ISSUEDATEREVISIONLOCATION:PROJECT INFORMATION:TITLE:SHEET NUMBER:ARCHITECTURAL SEAL:CONSULTANTS (ENGINEER):461 FROM ROADPARAMUS, NJ 07652973.253.9393 TEL973.253.9390 FAXWWW.SARGARCH.COM02/14/17ISSUE TO CLIENT,LL, HOMELANDSECURITYDATE: 02/14/17RANGELINE CROSSINGSHOPPING CENTER1356 S. RANGELINE RD.SPACE 1370CARMEL, IN 46032AREA: 2,988 SQ. FT.DRAWN BY: DTREVIEWED BY: ECBPROJECT NUMBER: 1621-1702/23/17LL COMMENTS02/23/17CLIENT / LL NEW INTERNALLY ILLUMINATED TENANT SIGN TOBE PROVIDED BY TENANT SIGN CONTRACTOR INACCORDANCE WITH LANDLORD CRITERIA. ALLSIGNS UNDER SEPARATE PERMIT, TYPICAL.SIGN SHOWN IS FOR AESTHETIC PURPOSESONLY. REFER TO SIGN SHOP DRAWINGS FOREXACT GRAPHIC REPRESENTATION. SIGNVENDOR TO SUBMIT SIGN SHOP DRAWINGS FORLANDLORD APPROVAL.0'-0" A.F.F.T.O. WALKWAY7'-0" A.F.F.T.O. ENTRY DOORS9'-5 1/4" A.F.F.B.O. OVERHANGLEASE LINE.LEASE LINE.ADJACENT TENANTADJACENT TENANTEXISTING STORE FRONTGLAZING TO REMAIN,TYPICAL.EXISTING ALUMINUM FRAMEDGLASS ENTRY DOOR WITHTRANSOM ABOVE TO REMAIN.EXISTING STORE FRONTGLAZING TO REMAIN,TYPICAL.NEW EXTERIORLIGHT FIXTURELEASE LINEADJACENT TENANTCMU REAR WALL.EXISTING DOWNSPOUTTO REMAIN.ADJACENT TENANTLEASE LINELEASE LINE.0'-0" A.F.F.T.O. WALKWAY7'-0" A.F.F.T.O. NEW REARSERVICE DOORSLOCATION OF GASMETERS TO REMAIN.EXISTINGBOLLARDSTO REMAIN.ADJACENT TENANT REARSERVICE DOOR ANDCONCRETE PLATFORM @± 8" AFFSLOPEDPAVEMENT1'-6" VIF 1'-1 1/2"VIF DOCKBUMPEREXISTING CONCRETESTAIRS WITH NEWRAILING.3'-0"LINE REPRESENTSTHE EDGE OFBUILDING.EXISTING J-BOXTO REMAIN.NEW REARSERVICE DOORS.NOTE:G.C. TO PAINT DOORS AND NEWUTILITY BOXES/LINES TO MATCHBLDG. STANDARD FINISHES/COLORS.4A-3.0NEW STAIR HANDRAILPERMANENTLY FIXEDIN PLACE.NEW ADA HANDRAIL BY G.C.2A-3.04'-0"4'-0"EXPANDED PLATFORM6"1'-6"FIXED POST AND HANDRAILPROVIDED AND INSTALLED BYGC TYP.REMOVABLECHAIN1'-0"2'-8"3'-0"EXISTINGSTAIR WIDTH2'-0" 8' - 0 "3'-9"90°135°135°EXISTING CONDUITTO REMAIN.7'-0"8'-4" AREA OF EXISTING CONCRETE PAD AND STAIRS.CONCRETE FINISH TOBE BROOM SWEPT ANDSLOPED AWAY FROMBUILDING.IT IS INTENDED TO KEEPTHE EXISTING CONCRETEPLATFORM AND STAIRS INPLACE IF POSSIBLE ANDEXTEND PLATFORM ASSHOWN.NOTES:EXISTING CMU WALL (VIF).EXISTING CONC. SLAB (VIF).EXISTING CONC. WALL FOOTING (VIF).PAVING (VIF).CMU WALL, SEE PLAN.NEW 3,000 PSI CONC. FOOTING.(2) #5 CONT.#5 @ 18" O.C.#5 CONT.#5 VERT REINF. @ 32" 0.C.#5 DOWEL @ 16" O.C.NEW 8", 4,000 PSI CONC. SLAB.#5 @ 12" O.C., BOTTOM E.W.#5 DOWEL x 1'-0" LONG, DRILL AND INSTALL@ MID-DEPTH OF EXISTING FOOTING USINGHILTI HIT HY-150 ADHESIVE ANCHORINGSYSTEM (6" EMBED).2"Ø HOT DIPPED GALVANIZEDSCHEDULE 40 PIPE RAILING POSTHOT DIPPED GALVANIZEDEMBEDDED PIPE SLEEVE (6" LONG).1'-0"1'-0" 3'-0" MIN 1'-0"2'-0"ELEV= MATCHEXISTING FOOTINGELEV= MATCHEXISTING FOOTING2'-0"2'-0"VARIES REFER TO PLAN1'-6" MAX DATEWRITTEN DIMENSIONS HOLD PREFERENCE OVERSCALED DIMENSIONS. DO NOT SCALE THEDRAWINGS. THE CONTRACTORS MUST VISIT JOBSITE TO VERIFY ALL EXISTING CONDITIONS ANDDIMENSIONS BEFORE SUBMITTING BIDS. REPORTANY DISCREPANCIES OF ANY CONDITIONS WHICHMAY INTERFERE WITH THE PROPER EXECUTIONOF, THE CONTRACT TO THE TENANT'SREPRESENTATIVE. REPORT DISCREPANCIESDURING BIDDING PROCESS AND BEFORE STARTOF CONSTRUCTION. CHANGE ORDERS WILL NOTBE APPROVED FOR ISSUES ARISING FROM THEFIELD CONDITIONS OR CONFLICTS BETWEEN THEPLANS AND THE EXISTING CONDITIONS.CONTRACTOR'S NOTES:ISSUEDATEREVISIONLOCATION:PROJECT INFORMATION:TITLE:SHEET NUMBER:ARCHITECTURAL SEAL:CONSULTANTS (ENGINEER):461 FROM ROADPARAMUS, NJ 07652973.253.9393 TEL973.253.9390 FAXWWW.SARGARCH.COM02/14/17ISSUE TO CLIENT,LL, HOMELANDSECURITYDATE: 02/14/17RANGELINE CROSSINGSHOPPING CENTER1356 S. RANGELINE RD.SPACE 1370CARMEL, IN 46032AREA: 2,988 SQ. FT.DRAWN BY: DTREVIEWED BY: ECBPROJECT NUMBER: 1621-1702/23/17LL COMMENTS02/23/17CLIENT / LLEXTERIORELEVATIONSA-3.01PROPOSED STOREFRONT ELEVATION1/4" = 1'-0"2PROPOSED REAR ELEVATION1/4" = 1'-0"3PROPOSED CONCRETE PLATFORM PLAN1/2" = 1'-0"4SECTION THRU PROPOSED REAR CONCRETE PLATFORM1/2" = 1'-0"1 1'-0" 1'-4"16" DEEP TUBALL OTHERS TOBE 12" DEEP.6'-0" 2'-10"ACCESS PANEL12"X12" TILEFRANCISCAN SLATE"TERRAIN MARRONE"-FS98BULL NOSE 3" X12" TILE TRIMFRANCISCAN SLATE"TERRAIN MARRONE"- P-43C9PAINTED DRY WALL ABOVEHOOK FOR LEASHES -(2) AT EACH TUB.SCHLUTER TRIMSEE SPEC. INFO.FOR FAUCET & DRAINSPECS.(2) STEPSCL3'-6"10"10"CL3'-6"10"10"ACCESS PANELVINYL PLANK FLOORING- KARNDEANVAN GOGH VGW41T MERBAU.USE EPOXY ADHESIVE3'-0"1'-0"'REDGARD' WATERPROOFINGMEMBRANE UNDER TILENEW PARTITION - REFER TO SHEETA-1.0 FOR ADDITIONAL INFORMATION.NOTE:-SIMPLE GROUT PREMIXED 09 -NATURAL GRAYPROVIDE SCHLUTER QUADECTRIM IN 'TUSCAN BRONZE' FORVERTICAL EDGES AND STAIREDGING. SEE DETAIL #52'-10"1'-3"6'-0"12"X12" WALL TILE:SEE TILE SPEC UNDER DOGWASH SPECIFICATION12"X12" WALL TILE:SEE TILE SPECUNDER DOG WASHSPECIFICATION12"X12" WALL TILE:SEE TILE SPEC UNDER DOGWASH SPECIFICATION3"X12" BULLNOSE TILE:SEE TILE SPEC UNDER DOGWASH SPECIFICATIONCONTROL SWITCH4'-0"GFI OUTLET - REFER TO ELECTRICALSHEETS FOR MORE INFORMATIONSEE PLUMBING DRAWINGS FORFAUCET & DRAIN SPECIFICATIONSGFI OUTLET 3/4" PLYWOOD CONSTRUCTION AND'REDGARD' WATERPROOFING MEMBRANEAND TILEDEMISING WALL1'-0"1'-0"3'-0"PROVIDE SCHLUTER QUADECTRIM IN 'TUSCAN BRONZE' FORVERTICAL EDGES AND STAIREDGING. SEE DETAIL #5EQ.EQ.2'-10"5A-4.06'-0" 10"12"X12" WALL TILE:SEE TILE SPEC UNDER DOGWASH SPECIFICATION12"X12" WALL TILE:SEE TILE SPEC UNDER DOGWASH SPECIFICATION3"X12" BULLNOSE TILE:SEE TILE SPEC UNDER DOGWASH SPECIFICATIONCONTROL SWITCH4'-0"GFI OUTLET - REFER TO ELECTRICALSHEETS FOR MORE INFORMATIONSEE PLUMBING DRAWINGS FORFAUCET & DRAIN SPECIFICATIONS3/4" PLYWOOD CONSTRUCTION WITH'REDGARD' WATERPROOFINGMEMBRANE AND TILEGFI OUTLETNEW PARTITION - REFER TO SHEETA-1.0 FOR ADDITIONAL INFORMATION.NOTE:-SIMPLE GROUT PREMIXED 09 -NATURAL GRAYDEMISING WALLVINYL PLANK FLOORING- KARNDEANVAN GOGH VGW41T MERBAU.USE EPOXY ADHESIVED&D TECHNOLOGIES 'MAGNA-LATCH' -LEVER STYLE. PROVIDED AND INSTALLEDBY VENDOR, TYP.WELDED GATE WITH HINGES AND SQUARESTRINGERS - JERITH MANUFACTURINGCOMPANY, INC. STYLE #202. PROVIDED ANDINSTALLED BY VENDOR, TYP.± 9'-1 1/2"SEPARATE 110V 20 AMPCIRCUIT TO SWITCHED GFIDUPLEX RECEPTACLE.PROVIDED AND INSTALLEDBY VENDOR2A-4.03A-4.06A-4.0± 14'-9" 4"4A-4.0SEPARATE 110V 20 AMPCIRCUIT TO SWITCHED GFIDUPLEX RECEPTACLE.PROVIDED AND INSTALLEDBY VENDOR± 2'-3 1/2"1/2"3'-0"3 3/16"1 1/2"7"2'-10" 1" 2" 3'-6"METAL WELDED GATEWITH HINGES ANDSQUARE STRINGERS -JERITHMANUFACTURINGCOMPANY, INC. STYLE#202.1/2" CLEARANCEREQUIRED BETWEENGATE AND WALL .1/2" CLEARANCEREQUIRED BETWEENGATE AND WALL.POWERED MAGNETICLATCH - LEVER TYPEMOUNTED AT 34" A.F.F. D&DTECHNOLOGIES1/2"SPECIFICATION TUB DOG SHOWERFAUCET;-T&S BRASS AND BRONZE WORKS:#B-0235-LN COMBINATION FAUCET-LESS NOZZLE.#B-0426 SUPPLY NIPPLE UNIT 12"X3-3/8".#B-02030-K INSTALLATION KIT.#B-0413 SWIVEL TO RIGID ADAPTER.#B-GH GARDEN HOSE OUTLET ADAPTER 3/4" GARDENHOSE MALE X 3/8" NPSM.#B-0972 ATMOSPHERIC VACUUM BREAKER WITH 3/4"GARDEN HOSE FEMALE INLET AND MALE OUTLET.DRAINS:-EBBE#E4024 PVC 3PC DRAIN.#E4407 OIL RUBBER BRONZE GRATES.HAIRTRAPS:-INLINE DRAIN STRAINER - ENDURATILE: (Sourced through Daltile)-WALLS:P-43C9 FRANCISCAN SLATE "Terrain Marrone" 3"X12" BULLNOSE TRIM.FS98 FRANCISCAN SLATE "Terrain Marrone" 12"X12" FIELD.-WASH TUB:HLO8 HARTLAND "Sunset blend" MOSAIC 2"X2"X12".EDGE TRIM FOR TILE:-SCHLUTER BRUSHED ANTIQUE BRONZE OR TUSCAN BRONZE.:#Q100ABGB OR Q100TSOB#EV/Q100ABGB OR 3 EV/Q100TSOB END CAP.PROVIDE INSIDE AND OUTSIDE CORNERS.GROUT:-CUSTOM BUILDING PRODUCTS FUSION PRO SINGLE COMPONENT GROUT IN#122 "LINEN"FLOORING:-KARNDEAN:VAN GOGH VGW41T "MERBAU".USE 2 PART EPOXY ADHESIVE.DOG GATE:- JERITH MANUFACTURING COMPANY.:RESIDENTIAL GATE STYLE #202 42" H X 36" W1/2" CLEARANCE REQUIRED BETWEEN GATE AND WALL .- LATCH:D&D TECHNOLOGIES MAGNA-LATCH - LEVER STYLEHARDWARE FOR DOG WASH LEASH HOOK :TOGGLE BOLT- 1/4" X 2-1/2" TOGGLE STRAPS WITH SCREWS- MANUFACTURER: THE HILLMAN GROUP- STEEL CONSTRUCTIONEYEBOLT- 1/4" X 2" EYE BOLTS WITH NUT- STAINLESS STEEL EYE BOLTWASHER- 1/4" X 1-1/4" FENDER WASHER- STAINLESS STEEL CONSTRUCTION1. MODULAR DOG WASH STATION ASSEMBLY, INCLUDING FINISHES, EQUIPMENT,PLUMBING AND ELECTRICAL FIXTURES, SHALL BE PROVIDED AND INSTALLED BYTHE TENANT'S VENDOR.2. G.C. TO COORDINATE INSTALLATION OF DOG WASH STATION WITH THETENANT'S VENDOR AND PROVIDE BLOCKING AT ADJACENT PERIMETER WALL ASREQUIRED.3. G.C. TO MAKE ALL FINAL ELECTRICAL, PLUMBING, AND SANITARYCONNECTIONS AS REQUIRED.Schluter - QUADECSubstrate®TILETILEDATEWRITTEN DIMENSIONS HOLD PREFERENCE OVERSCALED DIMENSIONS. DO NOT SCALE THEDRAWINGS. THE CONTRACTORS MUST VISIT JOBSITE TO VERIFY ALL EXISTING CONDITIONS ANDDIMENSIONS BEFORE SUBMITTING BIDS. REPORTANY DISCREPANCIES OF ANY CONDITIONS WHICHMAY INTERFERE WITH THE PROPER EXECUTIONOF, THE CONTRACT TO THE TENANT'SREPRESENTATIVE. REPORT DISCREPANCIESDURING BIDDING PROCESS AND BEFORE STARTOF CONSTRUCTION. CHANGE ORDERS WILL NOTBE APPROVED FOR ISSUES ARISING FROM THEFIELD CONDITIONS OR CONFLICTS BETWEEN THEPLANS AND THE EXISTING CONDITIONS.CONTRACTOR'S NOTES:ISSUEDATEREVISIONLOCATION:PROJECT INFORMATION:TITLE:SHEET NUMBER:ARCHITECTURAL SEAL:CONSULTANTS (ENGINEER):461 FROM ROADPARAMUS, NJ 07652973.253.9393 TEL973.253.9390 FAXWWW.SARGARCH.COM02/14/17ISSUE TO CLIENT,LL, HOMELANDSECURITYDATE: 02/14/17RANGELINE CROSSINGSHOPPING CENTER1356 S. RANGELINE RD.SPACE 1370CARMEL, IN 46032AREA: 2,988 SQ. FT.DRAWN BY: DTREVIEWED BY: ECBPROJECT NUMBER: 1621-1702/23/17LL COMMENTS02/23/17CLIENT / LLMODULARDOG WASHPLANS & DETAILSA-4.0DOG WASH SPECIFICATIONS1PLAN AT MODULAR DOG WASH STATION1/2" = 1'-0"2FRONT ELEVATION1/2" = 1'-0"3SECTION THROUGH TUB3/4" = 1'-0"4SECTION AT STEPS3/4" = 1'-0"6DOG GATE ELEVATION3/4" = 1'-0"5EDGE DETAILN.T.S.DOG WASH INSTALLATION NOTESNOTE:MODULAR DOG WASH STATION TO BEPURCHASED THROUGH VENDOR.AAPEX CREATIONSCONTACT: PAUL STEWARTPHONE: (215) 778-7213EMAIL: CONTACT@AAPEX.USWWW.AAPEX.USFINAL ELECTRICAL AND PLUMBINGCONNECTIONS BY G.C.NOTE:ALL SPECIFICATIONS AREINCLUDED IN PRE-FABRICATEDUNITS BY AAPEX CREATIONS. 3'-0" MAX. 3 4 2 67'-0" 1 54'-0" F.R.P.1212128'-0" 4'-0" F.R.P. 4'-0" F.R.P. 78'-0" 8'-0"812 1 5 4 7 68'-0" 2 34'-0"F.R.P.124'-0" F.R.P.4523A-5.08'-9" F.R.P. 3'-6"1'-0"CL2'-3"72911 186A5.0W.H. 14'-0"F.R.P.1'-0"3'-0"9"9'-7 1/2"4'-0"F.R.P.105"1'-6"CLCLCL7"7'-9"CL 8'-4"6"3'-0"1'-6"CLCL1 1/2"9'-9"CLALIGNADJACENT TENANT(N.I.C)DATEWRITTEN DIMENSIONS HOLD PREFERENCE OVERSCALED DIMENSIONS. DO NOT SCALE THEDRAWINGS. THE CONTRACTORS MUST VISIT JOBSITE TO VERIFY ALL EXISTING CONDITIONS ANDDIMENSIONS BEFORE SUBMITTING BIDS. REPORTANY DISCREPANCIES OF ANY CONDITIONS WHICHMAY INTERFERE WITH THE PROPER EXECUTIONOF, THE CONTRACT TO THE TENANT'SREPRESENTATIVE. REPORT DISCREPANCIESDURING BIDDING PROCESS AND BEFORE STARTOF CONSTRUCTION. CHANGE ORDERS WILL NOTBE APPROVED FOR ISSUES ARISING FROM THEFIELD CONDITIONS OR CONFLICTS BETWEEN THEPLANS AND THE EXISTING CONDITIONS.CONTRACTOR'S NOTES:ISSUEDATEREVISIONLOCATION:PROJECT INFORMATION:TITLE:SHEET NUMBER:ARCHITECTURAL SEAL:CONSULTANTS (ENGINEER):461 FROM ROADPARAMUS, NJ 07652973.253.9393 TEL973.253.9390 FAXWWW.SARGARCH.COM02/14/17ISSUE TO CLIENT,LL, HOMELANDSECURITYDATE: 02/14/17RANGELINE CROSSINGSHOPPING CENTER1356 S. RANGELINE RD.SPACE 1370CARMEL, IN 46032AREA: 2,988 SQ. FT.DRAWN BY: DTREVIEWED BY: ECBPROJECT NUMBER: 1621-1702/23/17LL COMMENTS02/23/17CLIENT / LLTOILET ROOM PLANAND ELEVATIONSSCALE: 1/2" = 1'-0"ENLARGED TOILET ROOM PLAN1A-5.0SCALE: 1/2" = 1'-0"ENLARGED TOILET ROOM ELEVATION2SCALE: 1/2" = 1'-0"ENLARGED TOILET ROOM ELEVATION3SCALE: 1/2" = 1'-0"ENLARGED TOILET ROOM ELEVATION4SCALE: 1/2" = 1'-0"TOILET ROOM ELEVATION5SCALE: 1/2" = 1'-0"DRINKING FOUNTAIN ELEVATION6INSTALL NEW WALL MOUNTED ADA COMPLIANT GRAB BARS.NEW WALL MOUNTED ADA COMPLIANT SINK.INSTALL NEW WALL MOUNTED MIRROR 2'-0" X 4'-0" W/ STL. STEELFRAME. MOUNT SO BOTTOM OF REFLECTED SURFACE IS 40" AFF.INSTALL NEW SURFACE MOUNTED PAPER TOWEL DISPENSER AND DISPOSALWITH 4" MAX PROJECTION.INSTALL NEW SURFACE MOUNTED TOILET PAPER. SANITARY NAPKIN DISPOSAL INWOMENS RESTROOM.PROVIDE ADA COMPLIANT PIPE INSULATIONS.PROVIDE ADA COMPLIANT FLOOR MOUNTED TOILET.NEW HI-LOW DRINKING FOUNTAIN.NEW WATER HEATER.NEW MOP SINK.ADA COMPLIANT SIGNAGE.F.R.P. UP TO 4'-0" A.F.F.MFG. NO.MOUNTINGDESCRIPTIONMFGREMARKSPLUMBING FIXTURE NOTEREFER TO PLUMBING SPECIFICATIONS SHEET FOR PLUMBING FIXTURE SCHEDULE.GENERAL NOTES FOR NEW TOILET ROOMS:1.ANY EXPOSED PLUMBING SHALL BE WRAPPED W/ HANDICAPPED APPROVED WHITE VINYL DRAINCOVERS SUPPLIED AND INSTALLED BY G.C.2.TOILET ROOM VINYL TILE ON FLOOR SHALL COMPLY TO FED. SPEC. L-F-475A (3) TYPE II GRADE A.3.IN ADDITION, CLASS 'A' MARLITE F.R.P. UP TO 48" A.F.F. - COLOR = P-106 BEIGE OR SIMILAR, USEMATCHING MARLITE EDGINGS & CORNERS. SEAL PERIMETER OF F.R.P. W/ CLEAR SILICONE SEALANT.TYPICAL FOR ALL INTERIOR TOILET ROOM & DRINKING FOUNTAIN WALLS.4.PROVIDE NON-COMBUSTIBLE F.R.T.W. IN WALL BLOCKING, IN ALL LOCATIONS OF EQUIPMENT ANDACCESSORIES REQUIRED TO BE WALL MOUNTED.5.GRAB BARS TO MEET A 250 LB LOAD.6.WATER CLOSET FLUSH CONTRAS TO BE ON OPEN SIDE ROOM.7.TOILET ROOM SINK SHALL HAVE A TEMPERATURE LIMITING DEVISE SEAT AT 110° MAX SEE LAV-1 ONSHEET P-2.0.8.WATER CLOSET TO HAVE AN ELONGATED SPLIT SEAT.B-6806.99 X 18"B-6806.99 X 42"B-6806.99 X 36"TBDBOBRICKBOBRICKBOBRICKBOBRICKTBDSURFACESURFACESURFACESURFACESURFACETOILET PAPER DISPENSER18 " VERTICAL GRAB BAR42" HORIZ. GRAB BAR36" HORIZ. GRAB BAR2'-0" x 4'-0" FRAMED MIRRORSUPPLIED & INSTALLED BYG.C. - G.C. TO SUPPLY THISSPECIFIED ITEM OR SIMILARB-279BOBRICKSURFACEPAPER TOWEL DISPOSALB-253BOBRICKSURFACEPAPER TOWEL DISPENSERB-270BOBRICKSURFACESANITARY NAPKIN DISPOSALACCESSIBILITY NOTES1. ALL ACCESSIBILITY REQUIREMENTS MUST COMPLY WITH THE CONSTRUCTIONCONSTRUCTION CODE.2. REFER TO SHEET A1.1 FOR GENERAL ACCESSIBLE TOILET ROOM DETAILS.3. REFER TO SHEET A-1.1 FOR GENERAL ACCESSIBLE SIGNAGE DETAILS. 1 2 3 4 5 6 7 8 9 10 11TOILET ROOM KEYED NOTESTOILET ROOM ACCESSORIES SCHEDULEGENERAL NOTES12B-6857SUPPLIED & INSTALLED BYG.C. - G.C. TO SUPPLY THISSPECIFIED ITEM OR SIMILARSUPPLIED & INSTALLED BYG.C. - G.C. TO SUPPLY THISSPECIFIED ITEM OR SIMILARSUPPLIED & INSTALLED BYG.C. - G.C. TO SUPPLY THISSPECIFIED ITEM OR SIMILARSUPPLIED & INSTALLED BYG.C. - G.C. TO SUPPLY THISSPECIFIED ITEM OR SIMILARSUPPLIED & INSTALLED BYG.C. - G.C. TO SUPPLY THISSPECIFIED ITEM OR SIMILARSUPPLIED & INSTALLED BYG.C. - G.C. TO SUPPLY THISSPECIFIED ITEM OR SIMILARSUPPLIED & INSTALLED BYG.C. - G.C. TO SUPPLY THISSPECIFIED ITEM OR SIMILAR 8 VD EXTERIORCOVERED WALKWAYADJACENT TENANT ADJACENT TENANTEXTERIOR EM/NL MODULAR DOG WASH 002 SALES AREA 001 UNISEX TOILET ROOM 003 EM/NL250 SD-1 250 SD-1 250 SD-1 225 SD-1 250 SD-1 250 SD-1 250 SD-1 225 SD-1 250 SD-1 250 SD-1 250 SD-1 250 SD-1 250 SD-1 250 SD-1 250 SD-1 250 SD-1 10 RTU-1 VDVDVD VD VD VD VD VDVDVDVD VD VD VD VD T RTU-1 - SDT 2 S 3 5 EF-1 BD 4 50 CD VD 6" DIA. 6" DIA. 12" DIA.14" DIA. 14" DIA.14" DIA. 14" DIA.12" DIA. 12" DIA.12" DIA.18" DIA.18" DIA. 24" DIA. 3,150 FM FULL SIZE RETURN WITH WIRE MESH SCREEN. 9 7 5 EF-2 BD 6 8" DIA. 1 10 10 10 10 10 10 101010 10 10 10 11 12 1MECHANICAL FLOOR PLAN SCALE1/4" = 1'-0" M1.0 MECHANICAL FLOOR PLAN 2MECHANICAL SCHEDULE SCALE:NONE REMOTE TEST STATION WITH AUDIBLE AND VISUAL ALARM FOR DUCT SMOKE DETECTOR MANUFACTURED BY SIMPLEX MODEL 4098-9842. SMOKE DETECTOR TEST STATION - SDT 100 SD S T LEGEND TS CO2 VD VD1 SQUARE CEILING SUPPLY AIR DIFFUSER 24/24 SQUARE CEILING SUPPLY AIR DIFFUSER 12/12 ROUND SUPPLY AIR DIFFUSER CEILING RETURN AIR GRILLE THERMOSTAT TEMPERATURE SENSOR CARBON DIOXIDE SENSOR NEW DUCTWORK NEW DUCTWORK WITH ACOUSTICAL LINING EXISTING DUCTWORK VOLUME DAMPER CABLE OPERATED VOLUME DAMPER 4W 12" DIA. N X/Y TR SAD RET BD FD SD FSD (R) (E) (N) FC EQUIPMENT LABEL CFM/TONNAGE DIFFUSER NECK SIZE DIFFUSER AIRFLOW PATTERN X=DUCT WIDTH Y=DUCT HEIGHT SUPPLY AIR DIFFUSER RETURN AIR GRILLE TOP REGISTER FIRE DAMPER SMOKE DAMPER FIRE/SMOKE DAMPER BACK DRAFT DAMPER PHOTOELECTRIC SMOKE DETECTOR EXISTING RELOCATED NEW FLEXIBLE CONNECTION FIELD CONNECTION PET VALU (CFM) S/A O/A E/A -- SALES PRESSURIZATION (O/A) - (E/A)=+850 CFM -225 CFM NET BUILDING PRESSURIZATION =+625 CFM RTU-1 EF-1 - 150 TOTAL MARK 4,000 - AIR BALANCE SCHEDULE 4,000 75 /TW /KF - --EF-2 225 ALL ROOF PENETRATIONS TO BE PERFORMED BY LANDLORDS ROOFING CONTRACTOR AT TENANTS EXPENSE. 1. 2. NOTES: (NOT ALL MAY APPLY) EXHAUST FAN SCHEDULES NOTESWEIGHTFAN TYPEMODELMANUFACTURERVOLTS/ PH MOTOR HPRPME.S.P. "WGCFMSERVICE 17SP-A 190DOG WASH 150 0.25 1400 1/6 115/1 DIRECTGREENHECK EF-1 PROVIDE GRAVITY BACKDRAFT DAMPER. FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. PROVIDE INDEPENDENT WEATHER PROOF DISCONNECT SWITCH IN SIGHT OF THE EQUIPMENT. 3. 1,2,3EF-2 THERMOSTAT SCHEDULE TOILET RM.1,2,324SP-A750.55 1333 1/10 115/1 DIRECTGREENHECK AIR DEVICE SCHEDULE MARK FACE SIZE TYPE MOUNTING TYPE MAXIMUM N.C.DIRECTION MANUFACTURER MODEL NOTES NOTES: (NOT ALL MAY APPLY) 1.PROVIDE NECESSARY MOUNTING HARDWARE AND ACCESSORIES AS REQUIRED FOR INTENDED INSTALLATION. 2.AIR DEVICE(S) SHALL BE FACTORY FINISHED #26 WHITE. 3.AIR DEVICE(S) SHALL BE INSTALLED WITH MANUFACTURER AVAILABLE MOLDED INSULATION BACKING. FIELD FABRICATED INSULATION BACKING IS NOT ALLOWED (UNLESS FIRST APPROVED BY THE OWNER'S CONSTRUCTION MANAGER). CD SUPPLY 30 4-WAY TITUS TMS 1,2,3CEILING12X12 SD-1 SUPPLY 30 1-WAY TITUS 300RL 1,2,3SURFACE12X8 850 850 THERMOSTAT BY MECHANICAL CONTRACTOR THERMOSTAT SHALL BE MANUFACTURED BY HONEYWELL, MODEL VisionPRO WIFI (TH8321WF1001). THERMOSTAT SHALL BE TOUCHSCREEN PROGRAMMABLE 7-DAY TYPE. PROVIDE LOCKING GUARD COVER. MOUNT AT 4'-0" AFF. T KEY NOTES 1 2 3 4 5 6 7 8 9 10 VERIFY FINAL PLACEMENT OF 24/7 EXISTING PROGRAMMABLE THERMOSTAT AND NEW TEMPERATURE SENSORS WITH ARCHITECTURAL FLOOR PLAN AND INTERIOR ELEVATIONS. PROVIDE NEW CEILING MOUNTED CABINET FAN AT 11'-0" AFF FOR EXHAUST. FAN SHALL BE CONTROLLED BY AN INDEPENDENT SWITCH LOCATED INSIDE THE DOG WASH STATION. 11 UNDERCUT DOOR 1" FOR TRANSFER AIR. IF NOT EXISTING, ROUTE SUPPLY AND RETURN DUCTWORK FULL SIZE FROM THE EXISTING RTU CONNECTIONS THROUGH THE ROOF AS SHOWN. PROVIDE FLEXIBLE CONNECTIONS AND TRANSITION THROUGH THE JOISTS AS REQUIRED. FACTORY INSTALLED SMOKE DETECTOR CAPABLE OF SHUTTING DOWN THE RESPECTIVE MECHANICAL UNIT UPON ACTIVATION. EXPOSED DUCTWORK SHALL BE INSTALLED AS INTERNALLY LINED SPIRAL RIGID ROUND WITH GALVANIZED SHEET METAL FINISH. BOTTOM OF DUCTWORK SHALL BE FLUSH WITH THE ADJACENT LIGHTS (11'-0" A.F.F.). PROVIDE NEW CEILING MOUNTED CABINET FAN FOR EXHAUST. ROUTE THE BRANCH EXHAUST DUCT TO MAIN EXHAUST DUCT TO EXTERIOR OF BUILDING. FAN SHALL BE INTERLOCKED WITH RESTROOM LIGHT SWITCH FOR SIMULTANEOUS OPERATION. 12 CONN 4" GALVANIZED SHEET METAL (26 GA.) CLOTHES DRYER DUCT FROM CLOTHES DRYER AND ROUTE THROUGH ROOF AND TERMINATE WITH GOOSENECK DRYER VENT WITH BACKDRAFT DAMPER (NO SCREWS). MAINTAIN A MIN. DISTANCE OF 10'-0" AWAY FROM ALL FRESH AIR INTAKES AND BUILDING OPENINGS. ROUTE 3" PVC FLUE VENT AND 3" PVC COMBUSTION AIR INTAKE OUT THRU ROOF AND TERMINATE PER MANUFACTURER'S INSTRUCTION. ROUTE NEW EXHAUST DUCT UP THROUGH ROOF WITH ROOF CAP AND INSECT SCREEN. MAINTAIN MINIMUM 10'-0" CLEARANCE FROM ALL AIR INTAKES AND BUILDING OPENINGS. COORDINATE ALL ROOF MODIFICATIONS WITH LANDLORD REPRESENTATIVE AND LANDLORD ROOFING CONTRACTOR. RETURN AIR PLENUM SHALL BE INTERNALLY LINED AS DESCRIBED IN THE GENERAL NOTES ON SHEET M2.0. BOTTOM OF RETURN PLENUM SHALL BE EVEN WITH THE BOTTOM OF THE ADJACENT SUPPLY MAIN(S). RETURN AIR INTAKE OPENING SHALL HAVE A MINIMUM FREE AREA OF 7 SQUARE FEET. PROVIDE 1/4"x1/4" CORROSION RESISTANT WIRE MESH SCREEN OVER INTAKE. 150 -- NOTE: CONSTRUCTION DOCUMENTS ARE BASED ON A SET OF DRAWINGS AND/OR INFORMATION PROVIDED BY PET VALU. SARGENTI ARCHITECTS AND SARGENTI'S ENGINEER SHALL NOT BE HELD RESPONSIBLE FOR ANY DISCREPANCIES BETWEEN THE DRAWINGS AND FIELD CONDITIONS. DATE WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS WILL NOT BE APPROVED FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS. CONTRACTOR'S NOTES: ISSUE DATE REVISION LOCATION: PROJECT INFORMATION: TITLE: SHEET NUMBER: ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): 461 FROM ROAD PARAMUS, NJ 07652 973.253.9393 TEL 973.253.9390 FAX WWW.SARGARCH.COM 02/14/17 ISSUE TO CLIENT, LL, HOMELAND SECURITY DATE: 02/14/17 RANGELINE CROSSING SHOPPING CENTER 1356 S. RANGELINE RD. SPACE 1370 CARMEL, IN 46032 AREA: 2,988 SQ. FT. DRAWN BY: DT REVIEWED BY: ECB PROJECT NUMBER: 1621-17 02/23/17 LL COMMENTS 02/23/17 CLIENT / LL Kenneth A. Fuller, P.E. 153 East Main St. Rockaway, NJ 07866 Tel: 973-784-4258 kfullerpe@msn.com VOLTS-PH-Hz EWBMBHSEDBMBHTHPR.P.M.CFM EXISTING ROOFTOP UNIT SCHEDULE COMP: NO.kW HPEAT COND: E.S.P. "W.C.NO.TYPE EFF. MANUFACTURER MODEL NO.TAG LOCATION MIN. OSA FAN:FILTER:ELECTRICAL:COOLING:POWER EXHAUST: HP GAS HEAT: EAT LAT OPER. WT.TONS:MCA MOCP INPUT MBH OUTPUT MBH UNIT: REMARKS:BASIS OF DESIGN: ROOFTOP UNIT WITH ENTHALPY CONTROLLED ECONOMIZER WITH POWER EXHAUST, LOW AMBIENT HEAD PRESSURE CONTROLS, SMOKE DETECTOR, PROGRAMMABLE THERMOSTAT AND 120V GFCI CONVENIENCE OUTLET. 4,000 1,1178503.0 118.0 8093.0 671.4"30%4EXISTING2" DISP.3/42-95 7/8 1,252#10 208-3-60 6052.6 200 162 10565 TRANE YHC120E310 RTU-1 1 VENTILATION /EXHAUST NOTES: •ROOF MUST BE RE-PITCHED FOR PROPER DRAINAGE. •EXHAUST CURB MUST BE FACTORY FABRICATED •FLEX DUCT MUST BE LIMITED TO 5 FEET. •EXHAUST MUST BE 5 FEET FROM DEMISING WALLS. •MUST SHOW DECK REINFORCEMENT DETAIL. •EXHAUST MUST BE LABELED WITH TENANT NAME AND SPACE NUMBER. •MUST DEFINE CODE AND HEALTH SAFETY FOR OCCUPANCY. AAA Roofing 317-635-2928 Kyle Price klp@aaaroofingcompany.com AIR DISTRIBUTION •ALL DUCTWORK SHALL BE GALVANIZED SHEET METAL, DESIGNED, SHOP FABRICATED AND INSTALLED TO SMACNA STANDARDS. DUCTBOARD IS NOT PERMITTED. •ALL SUPPLY AIR DUCTWORK EXTERNALLY INSULATED WITH THICK FOIL FACE INSULATION. •INTERNALLY LINED DUCTWORK MAY BE USED FOR ACOUSTIC PURPOSES ONLY, NOT AS A SUBSTITUTE FOR EXTERNAL INSULATION. •EXTERNALLY INSULATED FLEXIBLE DUCT, NOT TO EXCEED 5’-0” IN LENGTH, MAY ONLY BE USED FOR CONNECTION TO SUPPLY DIFFUSERS. FLEX DUCT SHALL BE FASTENED TO METAL DUCT AND DIFFUSER WITH MECHANICALLY TIGHTENED DRAW BANDS. •INSTALL VOLUME/CONTROL DAMPERS AS REQUIRED FOR PROPER BALANCING OF THE SUPPLY AND EXHAUST SYSTEMS. •DISPLAY WINDOWS MUST BE VENTILATED TO REMOVE LIGHTING HEAT GAIN. RETURN AIR •PROVIDE RELIEF GRILLES. SIZE AT ONE SQUARE FOOT OF GRILLE FOR 300 SQUARE FEET OF GROSS LEASABLE AREA. AIR BALANCE •TENANT MUST EMPLOY AN INDEPENDENT AIR-BALANCING FIRM DESIGNATED BY THE LANDLORD. PROVIDE A CERTIFIED AIR BALANCE REPORT TO THE LANDLORD WHEN CONSTRUCTION HAS BEEN COMPLETED. ALL BALANCING WORK SHALL BE SCHEDULED THROUGH THE LANDLORD’S FIELD REPRESENTATIVE. •TENANT SHALL ALSO INCORPORATE A DESIGN AIR BALANCE SUMMARY ONTO THE DESIGN DRAWINGS PRIOR TO SUBMISSION. SMOKE DETECTION •ALL SMOKE DETECTORS AT THE RETURN AIR OF THE UNIT AS REQUIRED BY CODE. •FIRE DAMPERS SHALL BE INSTALLED AS REQUIRED BY CODE. DRAWING SHALL INDICATE THE RATING AND LOCATION OF FIRE DAMPERS. PROVIDE SUFFICIENT ACCESS TO EACH FIRE DAMPER. ROOFTOP UNIT CONTROLS •CONTROL SYSTEM SHALL EMPLOY A SEVEN-DAY TIMECLOCK OR PROGRAMMABLE THERMOSTAT TO AUTOMATE EQUIPMENT OPERATION. SUPPLY/OUTDOOR AIR AND KITCHEN ODOR OR PROCESS EXHAUST FAN OPERATION SHALL BE CONTINUOUS DURING OCCUPIED HOURS. •CONTROLS SHALL PROVIDE FOR CLOSURE OF OUTSIDE AIR DAMPERS WHEN FANS ARE OFF TO PREVENT UNCONTROLLED INFILTRATION OF AIR. THE OUTSIDE AIR DAMPER SHALL BE OPENED DURING OCCUPIED OPERATION. •INCLUDE A SEQUENCE OF OPERATION FOR ALL MECHANICAL EQUIPMENT. CONDENSATE DRAINAGE •TRAP AND CONDENSATE DRAIN TO BE COPPER. CONDENSATE TRAP SHOULD BE AT A DEPTH SUFFICIENT TO OVERCOME POSITIVE/NEGATIVE STATIC PRESSURE OF FAN (3” MINIMUM). •ROUTE TO LANDLORD PROVIDED CONDENSATE LINE WITHIN TENANT’S LEASED SPACE WHERE THE LANDLORD HAS PROVIDED A CONDENSATE MAIN WITHIN THE BUILDING. •ROUTE TO CONCRETE SPLASH BLOCK SET ON TREAD PAD WHERE THE LANDLORD HAS NOT PROVIDED A CONDENSATE MAIN WITHIN THE BUILDING. IF CONDENSATE RUNOFF IS NOT PERMITTED ON ROOF, CONDENSATION DRAINS MUST TERMINATE INSIDE BUILDING INTO TENANT’S WASTE SYSTEM OR TO A ROOF DRAIN OR GUTTER. CONDENSATE ROOF PIPING SHALL BE SUPPORTED AS DIRECTED AND APPROVED BY LANDLORD. •CONDENSATE DRAIN PIPING SHALL BE INSULATED WITHIN TENANT’S SPACE. •CONDENSATE PUMPS ARE NOT ALLOWED. 1 1 1 M2.0 MECHANICAL SPECIFICATIONS / TW /KF DATE WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS WILL NOT BE APPROVED FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS. CONTRACTOR'S NOTES: ISSUE DATE REVISION LOCATION: PROJECT INFORMATION: TITLE: SHEET NUMBER: ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): 461 FROM ROAD PARAMUS, NJ 07652 973.253.9393 TEL 973.253.9390 FAX WWW.SARGARCH.COM DATE: 02/14/17 HANOVER CROSSING 449 EISENHOWER DRIVE HANOVER, PA 17331 AREA: 3,184 SQ. FT. DRAWN BY: DT REVIEWED BY: ECB PROJECT NUMBER: 1585-16 02/14/17 CLIENT, LANDLORD, BUILDING DEPT. ustom esigning & Engineering, PC 153 E. Main St. Rockaway, NJ 07866 Tel: 973-784-4258 www.customdande.com M3.0 MECHANICAL DETAILS 6BRANCH TAKE-OFF FITTING DETAIL SCALE: NONE 45° 45° EQUAL TO REQ'D BRANCH DUCT DIMENSIONS SEAL BRANCH TAKEOFF AIR TIGHT 1/4 BRANCH DUCT WIDTH, BUT MIN. 4" 1" MIN. ON TOP AND BOTTOM EQUAL TO REQ'D BRANCH DUCT DIA. ADJUSTABLE ELBOW RINGS MAIN DUCT SUPPLY AIRFLOW MAIN DUCT 1" MIN. ON TOP AND BOTTOM SUPPLY AIRFLOW 3SUPPPLY REGISTER DETAIL SCALE: NONE SUPPLY TAPSQUARE ELBOW AIR FLOW RETURN TAP AIR FLOW DOUBLE THICKNESS VANES BRANCH DUCT BRANCH DUCT L = 0.25 x W 3" MIN. 3" MAX. L 45° W L = 0.25 x W 3" MIN. 45° W L L = 0.25 x W 3" MIN. AIR FLOW W L 45° MANUAL AIR DAMPER WITH LOCKING QUADRANT SUPPLY GRILLE WITH INTEGRAL VOLUME DAMPER SUPPLY TAP WITH SUPPLY GRILLE R / W MUST BE GREATER THAN OR EQUAL TO 1.5. NO TURNING VANES REQUIRED.W / HR W / H ALTERNATE RECTANGULAR ELBOW ACCESS DOOR 7SUPPLY REGISTER DETAILS SCALE: NONE 12LOAD CALCULATION SCALE: NONE 11DUCTWORK DETAILS SCALE: NONE 8HANGING DUCTWORK DETAIL SCALE: NONE NOT TO SCALE SECTION A-ABEAM CLAMP (MAX WEIGHT 500 LBS). 1/2" CONTINUOUS THREADED ROD. A A TOP CHORD OF JOIST STRUCTURAL STEEL BEAM OPEN WEB STEEL JOIST ATTACHMENT DETAIL 1/2" CONTINUOUS THREADED ROD. BEAM CLAMP (MAX WEIGHT 500 LBS). NOT TO SCALE STEEL BEAM ATTACHMENT DETAIL TOP CHORD OF JOISTS. BEAM CLAMP (MAX. WEIGHT 500 LBS.) 1/2" CONTINUOUS THREADED ROD. MAX. SIDE INCHES THROUGH 12 13 THROUGH 30 31 THROUGH 54 55 THROUGH 84 OVER 84 DUCTWORK SUPPORT DETAIL ALUMINUM MIN. B & S GAUGE 24 (0.020 IN.) 22 (0.025 IN.) 20 (0.032 IN.) 18 (0.040 IN.) 16 (0.051 IN.) RECTANGULAR DUCTS MIN. GALV. SHT. GAUGE 26 (0.022 IN.) 24 (O.028 IN.) 22 (0.034 IN.) 20 (0.040 IN.) 18 (0.052 IN.) NOT TO SCALE NOT TO SCALE ROUND DUCTS LONGITUDINAL SEAM DUCT STEEL MIN. GALV. SHT. GAUGE 26 (0.022 IN.) 24 (0.028 IN.) 22 (0.034 IN.) 20 (0.040 IN.) 18 (0.052 IN.) ROUND DUCT SUPPORT DETAIL SPIRAL SEAM DUCT STEEL MIN. GALV. SHT. GAUGE 28 (0.019 IN.) 26 (0.022 IN.) 24 (0.028 IN.) 22 (0.034 IN.) 20 (0.040 IN.) DIAMETER INCHES THROUGH 12 13 THROUGH 18 19 THROUGH 28 29 THROUGH 36 37 THROUGH 52 FITTINGS STEEL MIN. GALV. SHT. GAUGE 26 (0.022 IN.) 24 (0.028 IN.) 22 (0.034 IN.) 20 (0.040 IN.) 18 (0.052 IN.) NOTE: DISTANCE BETWEEN DUCT HANGERS SHALL BE IN ACCORDANCE WITH THE RULES OF THE AGENCIES HAVING JURISDICTION. 1" X 16 GA. MIN (DUCTS OVER 2 SQ. FT.) MAX. 700 LBS. 1" X 18 GA. MIN (DUCTS UNDER 2 SQ. FT.) MAX. 420 LBS. FOR DUCTS OVER 49" WIDE, TURN METAL STRAP UNDER BOTTOM OF DUCT AND FASTEN METAL JOIST 3/8" MACHINE BOLT 2x2x16 GA. ANGLE METAL STRAP METAL JOIST TOP CHORD OF JOISTS. 1/2" DIA. CONTINUOUS THREADED ROD. MAX WEIGHT PER FOOT = 16 LBS. DUCT SIZE 36" DIA. MAX AIRFLOW VOLUME DAMPER CONICAL COLLAR BY MECH. CONTR. CLG.CLG. FLEX DUCT, MAX LENGTH 5'-0" DIFFUSER SHEET METAL SCREW AT INNER LINER. INNER NYLON 66 DUCTSTRAP CLAMP. NOTES: FLEXIBLE DUCT IS TO BE USED FOR VERTICAL DROPS ONLY. RUNOUTS AND ELBOWS ARE TO BE SHEETMETAL DUCT. THE MECHANICAL CONTRACTOR MUST PROVIDE ADAPTERS FOR DIFFUSERS WITH SQUARE AND RECTANGULAR NECKS AS REQUIRED. INNER LINER TO BE SECURED TO COLLAR BY NYLON STRAP AND THREE SHEET METAL SCREWS TO PREVENT LINER FROM SLIPPING OFF COLLAR. MAXIMUM FLEX DUCT IS 5 FEET. CUT SMALL SLIT IN LINER AT DAMPER ADJUSTMENT W/STRING OR WIRE MARKER TO SHOW LOCATION. 5-9-06 2ATTACHMENT TO STEEL JOIST DETAIL. SCALE: NONE 9WORK RESPONSIBILITY SCALE: NONE /LC / KF 5CEILING MOUNTED CABINET FAN DETAIL SCALE: NONE INTEGRAL INTAKE GRILLE AND FLANGE MOUNTING FOR GYP CEILING INSTALLATION ACOUSTICALLY INSULATED CABINET FAN HOUSING EXHAUST DUCTWORK, REFER TO PLANS FOR SIZE AND ROUTING FOR FITTING LAYOUT ROOF MOUNTED GRAVITY EXHAUST VENTILATOR CAP ROOF MOUNTED GRAVITY EXHAUST VENTILATOR ROOF CURB SUPPORT FAN FROM STRUCTURE 10NOT USED SCALE: NONE 1DRYER VENT THROUGH ROOF DETAIL SCALE: NONE 4EXHAUST FAN DETAIL SCALE: NONE 8" DIA. EXHAUST DUCT, BY MECHANICAL CONTRACTOR, TO CONNECT TO LANDLORD SUPPLIED TOILET EXHAUST DUCT. VERIFY LOCATION PRIOR TO BID. RUBBER-IN-SHEAR VIBRATION ISOLATORS EXHAUST FAN EXHAUST EXHAUST 6" DIA.6" DIA. 1/4" DIA. THREADED ROD (TYPICAL FOR 4, ONE ON EACH CORNER) BEAM CLAMP (MAX WEIGHT 500 LBS.) BACKDRAFT DAMPER VIBRATION ISOLATOR STEEL JOIST WEATHER PROOF DISCHARGE CAP W/ BIRD SCREEN SUPPLY REGISTER WITH INTEGRAL DAMPER VOLUME DAMPER WITH LOCKING QUADRANT CIRCULAR DUCT DATE WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS WILL NOT BE APPROVED FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS. CONTRACTOR'S NOTES: ISSUE DATE REVISION LOCATION: PROJECT INFORMATION: TITLE: SHEET NUMBER: ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): 461 FROM ROAD PARAMUS, NJ 07652 973.253.9393 TEL 973.253.9390 FAX WWW.SARGARCH.COM DATE: 02/14/17 HANOVER CROSSING 449 EISENHOWER DRIVE HANOVER, PA 17331 AREA: 3,184 SQ. FT. DRAWN BY: DT REVIEWED BY: ECB PROJECT NUMBER: 1585-16 02/14/17 CLIENT, LANDLORD, BUILDING DEPT. ustom esigning & Engineering, PC 153 E. Main St. Rockaway, NJ 07866 Tel: 973-784-4258 www.customdande.com THE "TENANT CRITERIA MANUAL" FORMS A PART OF THESE SPECIFICATIONS. ANY DISCREPANCY BETWEEN THESE SPECIFICATIONS AND THE "TENANT CRITERIA MANUAL" THE MANUAL SHALL SUPERSEDE. ANY EQUIPMENT REQUIRED OF THE MANUAL BUT NOT SHOWN ON THESE SPECIFICATIONS SHALL BE PROVIDED AT THIS CONTRACTOR'S EXPENSE. TENANT'S MECHANICAL CONTRACTOR SHALL ACCOMPLISH THE FOLLOWING: 1. REFURBISH THE EXISTING ROOFTOP UNIT TO "LIKE NEW" CONDITION. REPLACE FILTERS, BELTS, MOTORS AND ALL OTHER SERVICEABLE PARTS AS REQUIRED. POWER WASH COIL THOROUGHLY TO REMOVE ALL FOREIGN MATTER. UNIT MUST PERFORM TO NAMEPLATE SPECIFICATIONS. REPLACE IF REQUIRED. A. CONTRACTOR TO CONFIRM THAT THE EXISTING SYSTEM MEETS OR EXCEEDS THE REQUIREMENTS AS SHOWN ON THE HVAC CALCULATIONS. CONTRACTOR TO CONFIRM THAT ALL ITEMS INDICATED ARE PRESENT AND IN GOOD WORKING ORDER. ITEMS MISSING OR NOT FUNCTIONING MUST BE REPLACED AT THIS CONTRACTOR'S EXPENSE. TENANT'S MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL THE FOLLOWING: 1. THIS CONTRACTOR SHALL FURNISH AND INSTALL EXHAUST FANS, DUCTWORK, DIFFUSERS, REGISTERS, HANGERS, PROGRAMMABLE THERMOSTAT AND ALL ITEMS REQUIRED TO PRODUCE A COMPLETE AND OPERABLE HVAC SYSTEM. 2. DUCTWORK: THE MECHANICAL CONTRACTOR IS TO FURNISH AND INSTALL, IN COMPLIANCE WITH THE MOST RECENT SMACNA STANDARDS FOR LOW AND MEDIUM PRESSURE, NEW DUCTWORK, INSULATION, FLEX DUCT, GRILLES, REGISTERS, DIFFUSERS, VOLUME DAMPERS, FIRE DAMPERS, SMOKE DETECTORS, SECONDARY CONDENSATE DRAIN, ETC. NECESSARY TO RENDER THE SYSTEM OPERATIONAL AS DESCRIBED IN THESE PLANS AND SPECIFICATIONS AND AS REQUIRED BY THE LANDLORD, LOCAL AND STATE CODES. 3. ALL DUCTWORK SHALL BE HUNG AS HIGH AS POSSIBLE TO MAINTAIN ARCHITECTURAL CEILING HEIGHT REQUIREMENTS. 4. ALL OUTSIDE AIR AND UNEXPOSED DUCTWORK SHALL BE INSULATED WITH 2" THICK FIBERGLASS FIRE RETARDANT VAPOR SEAL INSULATION. DUCTWORK WITHIN 10' OF THE UNIT SHALL BE INTERNALLY LINED WITH 1 1/2" ACOUSTICAL INSULATION. DUCT DIMENSIONS ARE NET FREE AREA ONLY. DUCT SIZE MUST ACCOMMODATE INSULATION THICKNESS. 5. FIRE DAMPERS MUST BE INSTALLED AT ALL LOCATIONS WHERE DUCTWORK PENETRATES A FIRE RATED WALL. PROVIDE ACCESS DOORS AS REQUIRED. FIRE DAMPERS TO BE OF THE TYPE APPROVED BY THE AGENCIES HAVING JURISDICTION. 6. WHEN NEW DUCTWORK CONFLICTS WITH EXISTING DUCTWORK, PIPING, ETC., NEW DUCTWORK SHALL BE SET UP OR DOWN AS REQUIRED. 7. PROVIDE VOLUME DAMPERS ON ALL NEW SUPPLY AIR DUCT SPLITS AND TAPS. 8. POWER WIRING: A. THE ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL ALL EQUIPMENT AND MATERIAL REQUIRED TO PROVIDE POWER TO THE ROOFTOP UNIT FROM THE TENANT'S POWER SUPPLY. B. THE ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL A DISCONNECT SWITCH ON THE ROOFTOP UNIT. C. THE ELECTRICAL CONTRACTOR IS TO PROVIDE POWER WIRING TO THE EXHAUST FANS. 9. CONTROL WIRING AND CONTROLS: THE MECHANICAL CONTRACTOR IS TO FURNISH AND INSTALL ALL NECESSARY WIRING (IN CONDUIT IF REQUIRED) AND CONTROLS REQUIRED TO PROVIDE A COMPLETE AND OPERATING SYSTEM. 10. WHEN THE SMOKE DETECTOR, IN SUPPLY AND RETURN DUCTWORK, ACTIVATES IT SHALL SHUT DOWN THE ROOFTOP UNIT. 11. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF ALL CEILING DIFFUSERS AND REGISTERS. 12. THE MECHANICAL CONTRACTOR IS TO FURNISH AND INSTALL A CONDENSATE DRAIN SYSTEM PER THE MANUFACTURERS RECOMMENDATIONS AND THE LANDLORD'S REQUIREMENTS. INTERIOR CONDENSATE DRAIN LINE SHALL BE INSULATED WITH 1/2" THICK ARMAFLEX. PITCH 1/4" PER FOOT. 13. TENANT'S MECHANICAL CONTRACTOR IS RESPONSIBLE FOR COMPLYING WITH ALL THE LANDLORD'S SPECIFICATIONS FOR THIS INSTALLATION. 14. THIS CONTRACTOR IS TO HIRE LANDLORD'S SPECIFIED CONTRACTOR FOR ALL ROOF PENETRATIONS. 15. THE MECHANICAL CONTRACTOR, AS PART OF THEIR WORK, IS TO STENCIL THE TENANT NAME AND SPACE NUMBER ON ALL ROOFTOP EQUIPMENT WITH 4" HIGH BLOCK LETTERS (2" HIGH BLOCK LETTERS ON ALL SMALL EQUIPMENT WHERE 4" WILL NOT FIT) IN A COLOR APPROVED BY THE BUILDING MANAGER / CONSTRUCTION INDIVIDUAL. 16. IF STRUCTURAL DRAWINGS FOR HVAC EQUIPMENT SUPPORTS ARE NOT ALREADY INCORPORATED INTO THIS SET OF PLANS AND SPECIFICATIONS, THE MECHANICAL CONTRACTOR, AT THEIR OWN COST AND EXPENSE, AND AS PART OF THE BID TO THE G.C., IS TO HIRE A STRUCTURAL ENGINEER TO DESIGN THE SUPPORTS FOR THE NEW HVAC UNIT(S) AND A STRUCTURAL SUBCONTRACTOR TO FURNISH AND INSTALL SUCH HANGERS / SUPPORTS, COLUMNS, BEAMS, BRACING, ETC. TO HANG FROM THE STRUCTURAL AND / OR SUPPORT AT THE ROOF TOP FOR ALL NEW HVAC EQUIPMENT. G.C. TO SUBMIT AS REQUIRED ALL STRUCTURAL SHOP DRAWINGS TO THE LANDLORD'S ARCHITECT, AS REQUIRED, FOR APPROVAL, PRIOR TO STARTING WORK. 10-01-12 EXTERIORCOVERED WALKWAYADJACENT TENANT ADJACENT TENANTEXTERIOR 18" AFF J J J G.F.I. W.H. 110V 20 AMP L14-20R OUTLET +86" A.F.F. 86" AFF86" AFF J OUTLET MOUNTED @ 86" FOR TV 86" AFF 86" AFF MODULAR DOG WASH 002 48" (T.O. SWITCH) 48" (T.O. SWITCH) G.F.I. 72" (B.O. OUTLET) G.F.I. 72" (B.O. OUTLET) G.F.I.G.F.I.G.F.I.G.F.I. G.F.I. 18" AFF SALES AREA 001 UNISEX TOILET ROOM 003 18" AFF 18" AFF OUTLET MOUNTED @ 86" FOR TV J A-27 J A-23 A-25 G.F.I G.F.I 9 A-38 16 17 A-12 A-15 16 A-17 A-21 1 2 A-10 A-10 A-10 A-13 A-39,41 511 10 4 3 A-11 EXISTING A-4 15 A-11 12 A-8 A-9 14 A-18 8 A-14 6A-19 7 A-29 RTU-1 13 T SMOKE DETECTOR TEST STATION. REFER TO MECHANICAL DRAWINGS FOR MORE INFORMATION. SDT RECEPTACLE FOR OPEN SIGN. GFI GFI GFI GFI GFI GFI 28'-11 3/4" 28'-11 3/4" 38'-9"9'-0 3/4"9'-3 3/4"9'-3 3/4"17 17 6 6 6 A-16 A-5 WP/GFI OUTLET A-31,33,35 A-19 RTU-1 60 AMP WP DISC SW. E1.0 ELECTRICAL POWER PLAN POWER GENERAL NOTES 1. INSTALL ALL PIPE, ETC. AS HIGH AS POSSIBLE. 2.COORDINATE ALL WORK WITH OTHER TRADES AND EXISTING CONDITIONS AS REQUIRED TO PROPERLY INSTALL ALL SYSTEMS AS INTENDED, WITHIN THE CONFINES OF THE SPACE AVAILABLE, AND WITHOUT INTERFERENCES. 3.REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF FIXTURES. 4.NO PIPING SHALL BE ROUTED OVER THE TOP OF THE ELECTRICAL PANELS. 5.ALL MATERIALS EXPOSED WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPMENT INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E84. 6.GC TO PROVIDE ELECTRICAL DISCONNECTS PER LOCAL AND/OR STATE CODES TO ALL SIGNS. COORDINATE WITH SIGN VENDOR PRIOR TO INSTALLATION. 7.LIGHT SWITCHES, OUTLETS, AND ALL COVER PLATES TO BE ALMOND IN COLOR. POWER KEY NOTES (1) IG RECEP AT 4'-0" AFF AND (1) IG RECEP AT 8'-0" AFF.. COORDINATE EXACT ELECTRICAL REQUIREMENTS WITH ACTUAL EQUIPMENT IN FIELD PRIOR TO INSTALLATION. DUPLEX RECEPTACLE FOR WASHER MOUNTED AT 36" A.F.F. NEMA 14-30R 30AMP 220V RECEPTACLE FOR DRYER TO BE MOUNTED AT 60" A.F.F. THERMOSTAT FOR RTU-1. REFER TO MECHANICAL DRAWINGS FOR MORE INFORMATION. PROVIDE (1) CAT5 LINE FROM DEMARQ TO DVR CABINET. PROVIDE EXTRA 20 FEET OF CABLE AT EACH END. 1 2 3 4 5 6 7 8 10 11 12 NEW ELECTRICAL PANEL 'A' - 120/208V-3PH-4W REFER TO RISER DIAGRAM FOR MORE INFORMATION. 13 14 15 SINGLE CAT5e LINE FROM DVR CABINET TO LOW VOLTAGE BOX AT 86" AFF BY TV OUTLET. 10' COIL AT LOW VOLTAGE BOX AND 20' COIL AT DVR CABINET 16 PET VALUE VENDOR TO PROVIDE OUTLETS AND SWITCH IN MODULAR DOG WASH STATION.9 JUNCTION BOX TO BE MOUNTED ON CEILING, CONDUIT AND WIRE FOR OUTLET TO BE INSTALLED ON FIXTURE AT 80" A.F.F. AFTER FIXTURE INSTALLATION. GC TO COORDINATE LOCATION AND TIMING WITH PET VALU CONSTRUCTION MANAGER. 1730 AMP DISCONNECT SWITCH WITH LOCK-OFF CAPABILITY FOR STOREFRONT SIGN. VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS FOR CONNECTION TO STOREFRONT SIGN. DUPLEX RECEPTACLE FOR GAS FIRED HOT WATER HEATER. CONTRACTOR TO VERIFY EXACT LOCATION IN FIELD. /KF RECEPTACLE FOR TELEPHONE. CONTRACTOR TO VERIFY EXACT LOCATION IN FIELD. RECEPTACLE MOUNTED 6" ABOVE THE TOP OF THE STOREFRONT WINDOW PER NEC. PROVIDE (7) CAT5 LINES FROM DVR CABINET TO J-BOX. PROVIDE EXTRA 40 FEET OF CABLE AT J-BOX. PROVIDE EXTRA 20 FEET OF CABLE AT DVR CABINET. /CV PET VALU G.C. TO PROVIDE AND INSTALL POWER FOR FREEZER. 1ELECTRICAL POWER PLAN SCALE: 1/4" = 1'-0" PROVIDE (2) SEPARATE IG 20 AMP CIRCUITS TO DUPLEX RECEPTACLES ON J-BOX INSTALLED 3" AFF. DATE WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS WILL NOT BE APPROVED FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS. CONTRACTOR'S NOTES: ISSUE DATE REVISION LOCATION: PROJECT INFORMATION: TITLE: SHEET NUMBER: ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): 461 FROM ROAD PARAMUS, NJ 07652 973.253.9393 TEL 973.253.9390 FAX WWW.SARGARCH.COM 02/14/17 ISSUE TO CLIENT, LL, HOMELAND SECURITY DATE: 02/14/17 RANGELINE CROSSING SHOPPING CENTER 1356 S. RANGELINE RD. SPACE 1370 CARMEL, IN 46032 AREA: 2,988 SQ. FT. DRAWN BY: DT REVIEWED BY: ECB PROJECT NUMBER: 1621-17 02/23/17 LL COMMENTS 02/23/17 CLIENT / LL Kenneth A. Fuller, P.E. 153 East Main St. Rockaway, NJ 07866 Tel: 973-784-4258 kfullerpe@msn.com 1 EXTERIORCOVERED WALKWAYADJACENT TENANT ADJACENT TENANTEXTERIOR EM/NL A2 MODULAR DOG WASH 002 SALES AREA 001 UNISEX TOILET ROOM 003 A A A A DX1 X1D SEM/NLA A A A A A A A A A A A A A A A A A A A A A A S S S A-24 EF-2 A-3 J A-1 REG-9 1 2 OS J A-22 EF-2 A-24 A-24 A-24 EM/NL EM/NL EM/NL EM/NL EM/NL EM/NL EM/NL A-24 A-24 A-24 A-24 A-24 A-24 A-26 A-20 A-26 A-26 A-20 A-20A-26A-20A-24A-20 A-26 A-20 A-26 A-26 A-20 A-26A-26A-26 A-20A-26 A-24 2 1 2 2 54 3 E2.0 ELECTRICAL LIGHTING PLAN LIGHTING NOTE: NEC 2014 SECTION 700.12 (F) ALL UNIT EQUIPMENT (EMERGENCY LIGHTING) SHALL BE WIRED AHEAD OF SWITCH OR CONTROL OF NORMAL LIGHTING CIRCUIT SERVING THAT AREA. THE BRANCH CIRCUIT FEEDING THE UNIT EQUIPMENT SHALL BE THE SAME BRANCH CIRCUIT AS THAT SERVING THE NORMAL LIGHTING IN THE AREA AND CONNECTED AHEAD OF ANY LOCAL SWITCHES. THE BRANCH CIRCUIT THAT FEEDS UNIT EQUIPMENT SHALL BE CLEARLY IDENTIFIED AT THE DISTRIBUTION PANEL. IN A SEPARATE AND UNINTERRUPTED AREA SUPPLIED BY A MINIMUM OF THREE NORMAL LIGHTING CIRCUITS, A SEPARATE BRANCH CIRCUIT FOR UNIT EQUIPMENT SHALL BE FROM THE SAME PANELBOARD AS THAT OF THE NORMAL LIGHTING CIRCUITS AND PROVIDED WITH A LOCK-ON FEATURE. LIGHTING GENERAL NOTES 1.REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT FIXTURE LOCATIONS. 2.REFER TO LIGHTING FIXTURE SCHEDULE ON SHEET E2.0 FOR FIXTURE SPECIFICATIONS. 3.FINAL ARRANGEMENT OF EACH FIXTURE (AIMING) SHALL BE PROVIDED TO THE OWNER REPRESENTATIVE AFTER THE FIXTURE IS INSTALLED. 4.UNLESS NOTED OTHERWISE ON THE PLAN ALL ELECTRICAL LIGHT FIXTURE HEIGHTS SHALL BE FOLLOWED PER THE LIGHTING FIXTURE SCHEDULE. 5.ALL EMERGENCY LIGHTING AND EXIT SIGNAGE SHALL BE CONNECTED AHEAD OF SWITCHING FOR CONTINUOUS OPERATION. 6.PLENUM RATED CABLE TO BE USED WHERE REQUIRED WITHIN PLENUM RATED SPACES ABOVE CEILING. 7 ALL OUTLET AND SWITCH PLATE COVERS TO BE ALMOND. 1ELECTRICAL LIGHTING PLAN SCALE: 1/4" = 1'-0" 1 LIGHTING KEYED NOTES SPEAKER WIRED WITH 14 GA. SPEAKER CABLE TO DVR CABINET LOCATION. PROVIDE 20 FEET OF CABLE AT DVR CABINET SPEAKER TO BE: OPEN CEILING: YAMAHA NS-AW150 BLACK OR SIMILAR. GRID CEILING: LEGRAND 364764-02-V 6.5" SPEAKERS TO BE SUPPLIED AND INSTALLED BY G.C. MAXIMUM (2) TWO SPEAKER TO BE INSTALLED ON ANY SINGLE CHANNEL. MASTER LIGHTING SWITCH BANK. COORDINATE LOCATION OF SWITCHES WITH CONSTRUCTION MANAGER. REFER TO SHEET E3.0 DETAIL #2 FOR SWITCH DESIGNATION. 1 2 3 4 PROVIDE WALL MOUNTED, ULTRASONIC OCCUPANCY SENSOR WITH MANUAL BY-PASS NEW TRACK LIGHTING. CONNECT TO CIRCUITS INDICATED. PROVIDE (1) SINGLE POLE 20 AMP BREAKER FROM PANEL AS NEEDED FOR A FULLY FUNCTIONING SYSTEM. PROVIDE LOCAL SWITCHING FOR TRACK LIGHTING PER CIRCUIT AT LOCATION OF SWITCH BANK, COORDINATE LOCATION WITH PROJECT MANAGER PRIOR TO ANY WORKCON-TECH CURRENT LIMITING DEVICES 60W 120W 210W 240W 300W 360W 480W 600W 720W 840W 900W 960W 1,200W 1,440W 1,680W REG-05 REG-1 REG-2 REG-21 REG-3 REG-4 REG-5 REG-6 REG-7 REG-8 REG-9 REG-91 REG-10 REG-12 REG-14 0.5A 1A 1.75A 2A 2.5A 3A 4A 5A 6A 7A 7.5A 8A 10A 12A 14A CONTRACTOR TO FURNISH AND INSTALL CURRENT LIMITERS TO LIMIT THE WATTAGE AVAILABLE FOR THE TRACK. CONTRACTOR TO UTILIZE CON-TECH LIGHTING LA-23-R (TITLE 24 COMPLIANT-CALIF. ONLY) OR LA-23-RN (NON-TITLE 24 COMPLIANT) CURRENT LIMITING DEVICE OR EQUIVALENT. /KF/CV 5 SWITCH FOR DOG WASH EXHAUST FAN. COORDINATE EXACT LOCATION WITH PET VALU CONSTRUCTION MANAGER. DATE WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS WILL NOT BE APPROVED FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS. CONTRACTOR'S NOTES: ISSUE DATE REVISION LOCATION: PROJECT INFORMATION: TITLE: SHEET NUMBER: ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): 461 FROM ROAD PARAMUS, NJ 07652 973.253.9393 TEL 973.253.9390 FAX WWW.SARGARCH.COM 02/14/17 ISSUE TO CLIENT, LL, HOMELAND SECURITY DATE: 02/14/17 RANGELINE CROSSING SHOPPING CENTER 1356 S. RANGELINE RD. SPACE 1370 CARMEL, IN 46032 AREA: 2,988 SQ. FT. DRAWN BY: DT REVIEWED BY: ECB PROJECT NUMBER: 1621-17 02/23/17 LL COMMENTS 02/23/17 CLIENT / LL Kenneth A. Fuller, P.E. 153 East Main St. Rockaway, NJ 07866 Tel: 973-784-4258 kfullerpe@msn.com TENANT PET VALU NEW EXISTING TO REMAIN LANDLORD ELECTRICAL DISTRIBUTION M NEW ELECTRICAL METER (BY UTILITY CO.) NEW 200 AMP SERVICE DISCONNECT SWITCH. CONTRACTOR TO VERIFY EXACT TYPE OF FEEDER AND LOCATION IN FIELD PRIOR TO BID. NEW PANEL 'A' TO EXISTING RTU-1 WITH A NEW 60 AMP WP DISC SW. (3) #4 + (1) #10 GND, IN A 1-1/4" C. AND WP. GFCI SERVICE OUTLET. TORK SS410 BYPASS SWITCH ONE (1) NEW LIGHTING CONTACTOR - 8 POLES ASCO 918 STANDARD NEMA MECHANICALLY HELD WITH ACCESSORY 47 TO CONTROL INTERIOR LIGHTING. TC C1 NEW TIME CLOCK. (7) DAY CALENDAR TYPE. TORK DLC400BP. (4 POLE 10 AMP) A-20 A-26 A-1 A-19 A-14 NEW WIRING (3) #3/0 + (1) #4 GND IN A 2" C. NEW ELECTRICAL PANEL 'A' 120/208V-3PH-4W 225A / 200 MCB NEW 200 AMP E3.0 ELECTRICAL SCHEDULES GENERAL NOTES 1.ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES HAVING JURISDICTION. 2.THE ELECTRICAL CONTRACTOR SHALL OBTAIN ALL PERMITS AND PAY SUCH FEES AS MAY BE NECESSARY FOR INSPECTIONS, TESTS, AND OTHER SERVICES NECESSARY FOR THE COMPLETION OF HIS WORK. 3.CONTRACTOR SHALL VISIT THE SITE AND EXAMINE CONDITIONS OF THE PREMISES AND THE CHARACTER AND EXTENT OF WORK REQUIRED PRIOR TO BIDDING. ANY DIFFICULTIES IN COMPLYING WITH THE DRAWINGS AND SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER BEFORE BIDDING. 4.IT IS THE INTENT OF THESE DRAWINGS AND OTHER RELATED DOCUMENTS TO PRODUCE A COMPLETE AND FUNCTIONING ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIAL AND OTHER SERVICES AS MAY BE NECESSARY TO ACHIEVE THIS PRODUCT. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF THE ARCHITECT ANY DISCREPANCIES IN THE PLANS AND SPECIFICATIONS THAT WILL AFFECT THE WORK, PRIOR TO SUBMISSION OF HIS BID PRICE. 5.IF, DURING THE COURSE OF THE WORK, THE CONTRACTOR EXPERIENCES A PROBLEM WITH THE PERFORMANCE OF THE INSTALLATION RELATIVE TO THE PLANS AND SPECIFICATIONS, THE NATIONAL ELECTRICAL CODE, OTHER APPLICABLE CODES AND GOVERNING DOCUMENTS, THE CONTRACTOR SHALL BRING THE PROBLEM TO THE ATTENTION OF THE ARCHITECT AND/OR THE ENGINEER FOR RESOLUTION PRIOR TO EXECUTION OF THE WORK. 6.ALL MATERIAL SHALL BE NEW AND BEAR THE UL LABEL LISTED APPROVAL FOR ITS INSTALLED APPLICATION. 8.CIRCUIT BREAKERS USED FOR SWITCHING OF LIGHTING OR SIGN CIRCUITS SHALL BE APPROVED FOR SWITCHING DUTY AND SHALL BE MARKED "SWD" IN ACCORDANCE WITH N.E.C. ART. 240.83 (D). 9.PROVIDE "LOCKING" TYPE DEVICES ON ALL CIRCUIT BREAKERS CONNECTED TO EMERGENCY AND NIGHT LIGHTING, SIGNS, FIRE ALARM, AND SECURITY SYSTEMS. 11.ALL SERVICE EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH NEC ARTICLE 250. 14.ELECTRICAL PLANS ARE DIAGRAMMATIC. DO NOT SCALE DRAWINGS. 23.CONTRACTOR SHALL VERIFY WIRE SIZES, CIRCUIT BREAKER AND FUSE RATINGS FOR ALL HVAC EQUIPMENT, AND BRING TO THE ATTENTION OF THE ARCHITECT AND/OR THE ENGINEER ANY DISCREPANCIES AFFECTING THE WORK PRIOR TO PROCEEDING. 24.HORSEPOWER RATINGS INDICATED ON DRAWING MAY DIFFER FROM ACTUAL EQUIPMENT FURNISHED. IF FURNISHED EQUIPMENT DIFFERS FROM RATINGS ON DRAWINGS, CONTRACTOR SHALL NOTIFY ARCHITECT AND/OR THE ENGINEER FOR APPROPRIATE ACTION TO BE TAKEN. 25.PROVIDE APPROVED "HACR" TYPE CIRCUIT BREAKERS FOR ALL HEATING, AIR CONDITIONING, AND REFRIGERATION EQUIPMENT INDICATED FOR CONNECTION ON ELECTRICAL DRAWINGS. 26.ALL DEVICES AND COVER PLATES SHALL BE CONSTRUCTED OF STAINLESS STEEL MATERIALS. COLOR OF DEVICES AND MATCHING COVER PLATES SHALL BE AS SPECIFIED. 27.THE CONTRACTOR SHALL GUARANTEE ALL HIS WORK AND MATERIALS FOR A MINIMUM PERIOD OF ONE YEAR AFTER ACCEPTANCE BY OWNER. 28.IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO COORDINATE SERVICE REQUIREMENTS FOR POWER UTILITIES. 29.PROVIDE A #10 NEUTRAL CONDUCTOR FOR ALL MULTIWIRE RECEPTACLE BRANCH CIRCUITS. 30.FOR ALL EQUIPMENT RATED 100AMPS OR LESS, ELECTRICAL CONTRACTOR SHALL PROVIDE TERMINATIONS WHICH ARE LISTED FOR USE AT 75°C OR PROVIDE WIRING SIZED USING THE 60° CAPACITY. 31.RECEPTACLES ON SEPARATE CIRCUITS SHALL BE RATED 20 AMP, 120 VOLT. 32.WIRE AND CABLE SHALL BE COPPER, TYPE THHN/THWN, MINIMUM #12 AWG. SEE SPECIFICATIONS FOR EXCEPTIONS. 33.PANELBOARD DIRECTORIES SHALL BE UPDATED AND TYPED TO REFLECT ALL WORK DONE AS PART OF THIS PROJECT. 34.ALL NEW BRANCH CIRCUITS SHALL BE EQUIPPED WITH A MINIMUM #12 AWG GREEN EQUIPMENT GROUND CONDUCTOR. 35.ALL BUILDING WIRING SHALL BE RUN IN CONDUIT. CONDUIT RUN UNDERGROUND OR BELOW SLAB SHALL BE PVC SCHEDULE 40. INTERIOR CONDUIT SHALL BE EMT. EXPOSED EXTERIOR CONDUIT SHALL BE IMC OR RMC. 36.FOR IG RECEPTACLES, PROVIDE 2#12 GREEN GROUND WIRES IN BRANCH CIRCUIT BACK TO PANELBOARD. 37.UNLESS OTHERWISE INDICATED, BRANCH CIRCUITS SHALL BE 2#12, 1#12G, 3/4"C. 20A/120V BRANCH CIRCUIT LONGER THAN 100' AND 20A/277V BRANCH CIRCUIT LONGER THAN 200' WILL BE WITH #10 AWG 38.BOXES AND EQUIPMENT LOCATED ABOVE GYPSUM BOARD AND OTHER INACCESSIBLE CEILINGS SHALL BE INSTALLED IN ACCORDANCE WITH NEC. 39.CONTRACTOR SHALL INCLUDE IN HIS COST ALL EXPENSES INVOLVED IN DEMOLISHING EXISTING ELECTRICAL ITEMS AND MAKING GOOD OF ALL DAMAGES TO ADJOINING STRUCTURES OCCURRED. 3ELECTRICAL RISER DIAGRAM NOT TO SCALE 5PANEL SCHEDULES AND LOAD SUMMARY SCALE: NONE HOME RUN. DUPLEX RECEPTACLE @ 18" A.F.F. U.N.O. MOUNTED AT CODE HEIGHT. GROUND FAULT PROTECTED DUPLEX RECEPTACLE. SYMBOL DESCRIPTION ELECTRICAL LEGEND JUNCTION BOX. GROUND FAULT PROTECTED QUAD RECEPTACLE. LIGHT SWITCH. ELECTRICAL PANEL. DISCONNECT SWITCH. DATA RECEPTACLE. TELEPHONE RECEPTACLE. QUAD RECEPTACLE @ 18" A.F.F. U.N.O. MOUNTED AT CODE HEIGHT. 220V-1PH RECEPTACLE J TELEPHONE / DATA COMBINATION RECEPTACLE. SMOKE DETECTOR TEST STATION THREE WAY LIGHT SWITCH. (4W - FOUR WAY SWITCH ). WALL MOUNTED OCCUPANCY SENSOR. CEILING MOUNTED OCCUPANCY SENSOR. POWER POLE. NOTE: NOT ALL SYMBOLS MAY APPEAR ON DRAWINGS. SDT 4ELECTRICAL LEGEND SCALE: NONE 1LIGHTING FIXTURE SCHEDULE SCALE: NONE 2SALES LIGHTING SWITCH BANK SCALE: NONE NOTES: PROVIDE PERMANENT LABELS FOR EACH SWITCH SHOWING TYPE OF LIGHTING. SALES AREA TRACK LIGHTS SALES AREA FLUORESCENT SALES AREA FLUORESCENT A-20 BYPASS SWITCH /KF/CV A-26 A-1 DATE WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS WILL NOT BE APPROVED FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS. CONTRACTOR'S NOTES: ISSUE DATE REVISION LOCATION: PROJECT INFORMATION: TITLE: SHEET NUMBER: ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): 461 FROM ROAD PARAMUS, NJ 07652 973.253.9393 TEL 973.253.9390 FAX WWW.SARGARCH.COM 02/14/17 ISSUE TO CLIENT, LL, HOMELAND SECURITY DATE: 02/14/17 RANGELINE CROSSING SHOPPING CENTER 1356 S. RANGELINE RD. SPACE 1370 CARMEL, IN 46032 AREA: 2,988 SQ. FT. DRAWN BY: DT REVIEWED BY: ECB PROJECT NUMBER: 1621-17 02/23/17 LL COMMENTS 02/23/17 CLIENT / LL Kenneth A. Fuller, P.E. 153 East Main St. Rockaway, NJ 07866 Tel: 973-784-4258 kfullerpe@msn.com TYPE MANUFACTURER MODEL DESCRIPTION LAMP VOLTAGE MOUNTINGSYMBOLFIXTURE WATT. LAMP WATT. LIGHT FIXTURE SCHEDULE NOTE: NO SUBSTITUTIONS ARE ALLOWED FOR FIXTURES 'A' AND 'A3'. ANY OTHER LIGHTING SUBSTITUTIONS TO BE APPROVED BY PET VALU. (E) EXISTING (RE) RELOCATED (NL) FIXTURE CONNECTED TO NIGHT LIGHT CIRCUIT.(EM) FIXTURE WITH EMERGENCY BATTERY BACK-UP. LITHONIA LIGHTING IBG 1500LM SEF PFL GND MVOLT OZ10 50K 80CRI SUSPENDED @ 11'-0" A.F.F. TO BOTTOM OF FIXTURE THROUGHOUT SALES AREA (UNLESS NOTED OTHERWISE). 97LED LAMP 120- 15" WIDE X 25" LONG STANDARD EFFICIENCY LIGHT FIXTURE WITH A SEMI-DIFFUSE POLYCARBONATE LENS AND STANDARD DISTRIBUTION. CORD TO BE BLACK. A COLOR BLACK LITHONIA LIGHTINGA-EM 15" WIDE X 25" LONG STANDARD EFFICIENCY LIGHT FIXTURE WITH WITH EMERGENCY BATTERY PACK, A SEMI-DIFFUSE POLYCARBONATE LENS AND STANDARD DISTRIBUTION. CORD TO BE BLACK. A EM/NL A A2 A2 LITHONIA LIGHTING 2SP5-G-2-54T5HO-A12- MVOLT-GEB10PS 24" WIDE X 48" LONG 2-LAMP FLUORESCENT LIGHTING. (2-LAMPS) FP54/850/HO/ECO [20949] WHITE GRID MOUNTED AT TOILET ROOM. EM/NL A2 A2-EM LITHONIA LIGHTING 24" WIDE X 48" LONG 2-LAMP FLUORESCENT LIGHTING.WHITE GRID MOUNTED AT TOILET ROOM. SUSPENDED @ 11'-0" A.F.F. TO BOTTOM OF FIXTURE THROUGHOUT SALES AREA (UNLESS NOTED OTHERWISE). C C-TRACK CONTECH LIGHTING D D X1X1 (EM) LITHONIA LIGHTING LITHONIA LIGHTING 108 120/ 27754 120/ 277 TRACK: LT-2/4/6/8-B TRACK HEAD: CTL-601-B BLACK "H" STYLE TRACK WITH TRACK LIGHTING HEAD.BLACK (1- LAMP PER TRACK HEAD) TCP LED12BR30D50K -12012 SUSPENDED @ 11'-0" A.F.F. TO BOTTOM OF TRACK THROUGHOUT SALES AREA (UNLESS NOTED OTHERWISE). LHQM-LED-R-HO-M6 EMERGENCY EXIT COMBINATION WITH TWIN LAMP EMERGENCY LIGHTING. ELA-T-QWP-L0309-M12 TWIN LAMP EMERGENCY LIGHT 3W 3 1.5W 1.5 SURFACE MOUNTED. SURFACE MOUNTED. 120 120 2SP5-G-2-54T5HO-A12- MVOLT-GEB10PS-EL14 (2-LAMPS) FP54/850/HO/ECO [20949] 10854 GREY (LED) (LED)WHITE IBG 1500LM SEF PFL GND MVOLT OZ10 50K 80CRI BLACK LED LAMP 120 PET VALU NATIONAL ACCOUNT REPRESENTATIVE - CARMEN ALLEN TEL: 1-800-284-2024 X 3335 Email: petvalu@regencylighting.com www.regencylighting.com 97- E4.0 ELECTRICAL SPECS /KF/CV DATE WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS WILL NOT BE APPROVED FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS. CONTRACTOR'S NOTES: ISSUE DATE REVISION LOCATION: PROJECT INFORMATION: TITLE: SHEET NUMBER: ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): 461 FROM ROAD PARAMUS, NJ 07652 973.253.9393 TEL 973.253.9390 FAX WWW.SARGARCH.COM 02/14/17 ISSUE TO CLIENT, LL, HOMELAND SECURITY DATE: 02/14/17 RANGELINE CROSSING SHOPPING CENTER 1356 S. RANGELINE RD. SPACE 1370 CARMEL, IN 46032 AREA: 2,988 SQ. FT. DRAWN BY: DT REVIEWED BY: ECB PROJECT NUMBER: 1621-17 02/23/17 LL COMMENTS 02/23/17 CLIENT / LL Kenneth A. Fuller, P.E. 153 East Main St. Rockaway, NJ 07866 Tel: 973-784-4258 kfullerpe@msn.com TENANT CONNECTIONS •UNLESS ALREADY EXISTING AND IN COMPLIANCE WITH LANDLORD’S REQUIREMENT, TENANT IS REQUIRED TO INSTALL, UPGRADE AND/OR FURNISH ANY AND ALL EQUIPMENT, WIRING, CONDUIT, ETC. FOR TENANT’S ELECTRICAL AND TELEPHONE SERVICE INSTALLATION. •ANY MODIFICATION OF EXISTING BASE BUILDING SERVICES OR CONSTRUCTION MUST RECEIVE THE PRIOR WRITTEN APPROVAL FROM THE LANDLORD, PRIOR TO DRAWING SUBMISSION. •MODIFICATIONS TO EXISTING LANDLORD SYSTEMS SHALL BE PERFORMED BY A CONTRACTOR DESIGNATED BY THE LANDLORD. •CONDUITS WITH PULLWIRE TERMINATED IN SPACE FOR TENANT’S POWER AND COMMUNICATION CONNECTIONS AT A LOCATION AS DETERMINED BY LANDLORD. •TELEPHONE CONDUIT MAY OR MAY NOT BE EXISTING IN OLDER SECTIONS OF THE CENTER.FIELD VERIFY. •TEMPORARY POWER IS NOT PROVIDED. TENANT CONTRACTOR MUST INSTALL PERMANENT FEEDER CONDUCTORS FROM THE LANDLORD’S SERVICE DISTRIBUTION POINT IMMEDIATELY FOR USE AS THE SOURCE OF LIGHT AND POWER DURING CONSTRUCTION. •ANY AND ALL PIPING NOT REUSED, SERVING THE DEMISED PREMISES MUST BE REMOVED. •REUSE OF ALL OR PART OF EXISTING EQUIPMENHT IS SUBJECT TO THE FIELD VERIFICATION OF THE CAPACITY AND CONDITION OF THE COMPONENTS. CONTRACT DOCUMENTS SHALL PROVIDE MINIMUM PERFORMANCE PARAMETERS, REFURBISHING SPECIFICATIONS AND ESTABLISH A VERIFICATION PROCEDURE, INCLUDING AMANDATORY WRITTEN REPORT. THIS REPORT SHALL DETAIL INSPECTION AND SERVICE TO BE PERFORMED, REPAIR REPORTING PROCEDURE, ADDITIONAL RECOMMENDATIONS AND PERFORMANCE TEST RESULTS. COPIES OF FIELD VERIFICATION REPORT SHALL BE SUBMITTED TO THE LANDLORD TO VALIDATE REUSE. GROUNDING •GROUNDING MUST BE TO BUILDING STEEL WITH EXOTHERMIC WELD OR SPLIT BOLT CONNECTION. DO NOT GROUND TO COLD WATER PIPE. ELECTRICAL PANELS •TENANT SHALL PROVIDE SERVICE SIZING CALCULATIONS. ALL CALCULATIONS SHALL BE PER NEC. •TENANT SHALL PROVIDE A MAIN DISCONNECTING MEANS AT EACH PANELBOARD. •CIRCUIT BREAKERS SHALL BE BOLT ON, NOT PLUG IN TYPE. •ARRANGE LOAD TO MAINTAIN A BALANCE BETWEEN PHASES OF 10% OR LESS. •TENANT SHALL HAVE BREAKER LOCKS ON CONTROL AND TIMECLOCK CIRCUITS. •SWITCHING DUTY BREAKERS ON ALL DEVICES USED FOR TURNING LOADS ON/OFF. •24 HOUR/7 DAY TIMECLOCK IS REQUIRED TO CONTROL STOREFRONT ENTRY LIGHTS, SHOW WINDOW LIGHTS, SHOW WINDOW RECEPTACLES AND STOREFRONT SIGNAGE. •ELECTRICAL DEVICES, TIMECLOCKS, PANELS, CABINETS, ETC., SHALL BE MOUNTED ON A PLYWOOD BACKER BOARD. SERVICE ACCESS •ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIRING. FLUORESCENT LIGHTING •EXPOSED FLOURESCENT TUBES OR FIXTURES WITH PARACUBE, OR PRISMATIC LENSES ARE NOT PERMITTED IN PUBLIC AREAS. •BALLASTS SHALL BE HIGH POWER FACTOR, ELECTRONIC WITH CBM OR ETL LABEL AND HAVE A THD OF ± 20%. FIRE ALARM SYSTEM •TENANT SHALL FURNISH AND INSTALL FIRE ALARM HORN/STROBE TO MEET ADA AND LOCAL FIRE DEPARTMENT REQUIREMENTS. CONDUIT AND WIRING •ALL WIRING MUST BE IN CONDUIT. FLEXIBLE CONDUIT SHALL BE MC ONLY. DO NOT LOOP EXCESS FLEXIBLE ONDUIT IN CEILING SPACE. •NO FLEXIBLE CONDUIT SHALL BE PERMITTED WITHIN THE DEMISING WALLS. ALL CONDUITS SHALL BE CONCEALED WHERE POSSIBLE. •EXPOSED CONDUIT SHALL BE INSTALLED IN STRAIGHT LINES, PARALLEL WITH OR AT RIGHT ANGLES TO THE BUILDING STRUCTURE. •WIRE SHALL BE COPPER THHN OR THWN WITH INSULATION. •ALL WIRING SHALL BE COLOR CODED AS FOLLOWS: 208/120V SYSTEMS480/277V SYSTEMS PHASE A – BLACKPHASE A - BROWN PHASE B – REDPHASE B - ORANGE PHASE C – BLUEPHASE C – YELLOW NEUTRAL – WHITENEUTRAL – WHITE W/TRACER OR GRAY HVAC WIRING •TENANT SHALL PROVIDE A MAIN DISCONNECTING MEANS AT EACH HVAC UNIT. •ROOFTOP UNITS AND EXHAUST FANS, IF REQUIRED, ARE TO BE WIRED THROUGH THEIR ROOF CURBS IF SO DESIGNED, OR UTILIZE FACTORY FABRICATED ROOF PIPING CURBS. PITCH POCKETS ARE NOT PERMITTED. •A 110V, DUPLEX OUTLET SHALL BE INSTALLED WITHIN REACH OF THE HVAC UNIT. 1 PB-1 HI-1HI-1 3" WCO WH-1 5 PB-1 4 6 1 3 3 SS-1 WM 2 3" W.C.O. EXTERIORCOVERED WALKWAYADJACENT TENANT ADJACENT TENANTEXTERIOR W.H. MODULAR DOG WASH 002 SALES AREA 001 UNISEX TOILET ROOM 003 DF-1 7 WC LAV 3" F.C.O. GENERAL NOTES 1.KEY NOTES WITH ELLIPTICAL SYMBOL AND NUMBER CORRESPOND TO KITCHEN EQUIPMENT SHOWN IN PLAN SHEETS. 2.ALL EXPOSED PIPING IN PUBLIC AREAS SHALL BE INSTALLED AS TIGHT AS POSSIBLE TO THE WARM SIDE OF THE EXPOSED ROOF STRUCTURE. 3.THE INSTALLATION OF THE PLUMBING SYSTEMS SHALL BE COORDINATED WITH ALL ELECTRICAL AND MECHANICAL EQUIPMENT, AND STRUCTURAL SLAB AND FRAMING. 4.REFER TO PLUMBING SHEET P2.0 FOR PLUMBING FIXTURE AND EQUIPMENT SCHEDULES INCLUDING SPECIFICATIONS AND ROUGH-IN SIZES. 5.ALL WALL PIPING STUB-OUTS SHALL BE SECURELY TIED TO THE STRUCTURE WITH SUFFICIENT BACKING TO ELIMINATE MOVEMENT. FINAL CONNECTIONS TO SINKS SHALL BE HARD PIPED. 6.PITCH ALL WASTE AND DRAIN LINES A MINIMUM OF 1/4" PER FOOT IN THE DIRECTION OF FLOW, OR AS REQUIRED BY LOCAL CODE. 7.ALL OPENINGS IN DWV SYSTEMS RESULTING FROM INSTALLATION ROUGH-IN SHALL BE PROTECTED WITH A TEST PLUG THAT IS SECURELY LOCKED IN PLACE UNTIL FINAL FINISHED CONNECTIONS ARE INSTALLED. 8.PLUMBING CONTRACTOR TO ARRANGE AND PAY FOR ALL REQUIRED FEES, PERMITS, AND MISCELLANEOUS COSTS ASSOCIATED WITH THE PLUMBING WORK PER LOCAL PLUMBING CODES. 9.ALL PENETRATIONS IN FIRE RATED WALL ASSEMBLIES SHALL BE SEALED WITH UL LISTED FIRE STOPPING MATERIAL. P1.0 PLUMBING FLOOR PLAN /LC /KF 1SANITARY PLAN SCALE: 1/4" = 1'-0" KEY NOTES 1 2 3 4 3" SANITARY SEWER PIPING TO CONNECT TO EXISTING SANITARY MAIN. VERIFY EXACT LOCATION AND POINT OF CONNECTION IN FIELD PRIOR TO BID. CONNECT 3" DRAIN LINE FROM EACH MODULAR WASH STATION SANITARY HOOKUPS TO NEW 3" SANITARY SEWER LINE. VERIFY EXACT LOCATION WITH MANUFACTURER IN THE FIELD. ROUTE DRAIN LINES FROM WATER HEATER TO INDIRECT TERMINATION AT SERVICE SINK. PROVIDE 2" SANITARY AND 1 1/2" VENT CONNECTION FOR WASHING MACHINE. 5 6 7 WATER HEATER SHALL BE WALL MOUNTED AS SHOWN ON PLAN. REFER TO INSTALLATION DETAIL ON SHEET P2.0. PROVIDE 2" SANITARY AND 1 1/2" VENT CONNECTION FOR HI/LO DRINKING FOUNTAIN. ROUTE 3" VENT UP THROUGH ROOF. VERIFY EXACT LOCATION IN FIELD PRIOR TO BID. DATE WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS WILL NOT BE APPROVED FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS. CONTRACTOR'S NOTES: ISSUE DATE REVISION LOCATION: PROJECT INFORMATION: TITLE: SHEET NUMBER: ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): 461 FROM ROAD PARAMUS, NJ 07652 973.253.9393 TEL 973.253.9390 FAX WWW.SARGARCH.COM 02/14/17 ISSUE TO CLIENT, LL, HOMELAND SECURITY DATE: 02/14/17 RANGELINE CROSSING SHOPPING CENTER 1356 S. RANGELINE RD. SPACE 1370 CARMEL, IN 46032 AREA: 2,988 SQ. FT. DRAWN BY: DT REVIEWED BY: ECB PROJECT NUMBER: 1621-17 02/23/17 LL COMMENTS 02/23/17 CLIENT / LL Kenneth A. Fuller, P.E. 153 East Main St. Rockaway, NJ 07866 Tel: 973-784-4258 kfullerpe@msn.com PB-1PB-1 7 2 3 6 4 8 4 8 9 1 DF-1 WM SS-1 5 WH-1 7EXTERIOR COVERED WALKWAYADJACENT TENANT ADJACENT TENANTEXTERIOR W.H. MODULAR DOG WASH 002 SALES AREA 001 UNISEX TOILET ROOM 003 WC LAV P1.1 PLUMBING WATER SUPPLY PLAN /LC /KF 1WATER SUPPLY PLAN SCALE: 1/4" = 1'-0" KEY NOTES ALL PET BAY FAUCET (T &S BRASS B-0669-PCL) ARE PROVIDED AND INSTALLED BY VENDOR. WATER HEATER SHALL BE WALL MOUNTED AS SHOWN ON PLAN. REFER TO INSTALLATION DETAIL ON SHEET P2.0. CONNECT 3/4" CW AND HW LINES TO MODULAR WASH STATION WATER HOOKUPS. VERIFY EXACT LOCATION WITH MANUFACTURER IN THE FIELD. INSTALL HOT AND COLD WATER SHUTOFF VALVES. EXTEND 1/2" HW & CW TO WASHING MACHINE AND SERVICE SINK. 1 2 3 4 5 6 7 8 ALL PET BAYS SUPPLIED BY T.G.C. WITH MIXING VALVES SET AT MAXIMUM 110F. THROUGH AAPEX CREATIONS INC. INSTALLATION TO BE DONE BY VENDOR AAPEX CREATIONS INC. T.G.C. TO COORDINATE. FINAL CONNECTIONS BY T.G.C. PROVIDE BACKFLOW PROTECTION. SEE SHEET P3.0 RISER DIAGRAM. EXTEND NEW 3/4" CW TO EXISTING CW MAIN OF ADEQUATE SIZE. VERIFY EXACT LOCATION IN FIELD PRIOR TO BID. 9 EXTEND 1/2" CW TO HI/LO DRINKING FOUNTAIN. DATE WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS WILL NOT BE APPROVED FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS. CONTRACTOR'S NOTES: ISSUE DATE REVISION LOCATION: PROJECT INFORMATION: TITLE: SHEET NUMBER: ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): 461 FROM ROAD PARAMUS, NJ 07652 973.253.9393 TEL 973.253.9390 FAX WWW.SARGARCH.COM 02/14/17 ISSUE TO CLIENT, LL, HOMELAND SECURITY DATE: 02/14/17 RANGELINE CROSSING SHOPPING CENTER 1356 S. RANGELINE RD. SPACE 1370 CARMEL, IN 46032 AREA: 2,988 SQ. FT. DRAWN BY: DT REVIEWED BY: ECB PROJECT NUMBER: 1621-17 02/23/17 LL COMMENTS 02/23/17 CLIENT / LL Kenneth A. Fuller, P.E. 153 East Main St. Rockaway, NJ 07866 Tel: 973-784-4258 kfullerpe@msn.com TENANT CONNECTIONS •UNLESS ALREADY EXISTING AND IN COMPLIANCE WITH LANDLORD’S REQUIREMENTS, TENANT IS REQUIRED TO INSTALL, UPGRADE AND/OR FURNISH ANY AND ALL EQUIPMENT, PIPING, ETC.FOR TENANT’S PLUMBING SERVICE INSTALLATION. •ANY MODIFICATION OF EXISTING BASE BUILDING SERVICES OR CONSTRUCTION MUST RECEIVE THE PRIOR WRITTEN APPROVAL OF THE LANDLORD, PRIOR TO DRAWING SUBMISSION. •MODIFICATIONS TO EXISTING LANDLORD SYSTEMS SHALL BE PERFORMED BY A CONTRACTOR DESIGNATED BY THE LANDLORD. •4” SANITARY TAP SHALL BE PROVIDED FOR TENANT’S CONNECTION AT A LOCATION AS DETERMINED BY LANDLORD. ONLY ONE CONNECTION TO THE LANDLORD’S MAIN IS PROVIDED AND PERMITTED. •TENANTS SHALL CONNECT TO EXISTING VENT HEADER IF EXISTING, OR EXTEND VENTS THRU ROOF. ALL ROOFING WORK MUST BE BY LANDLORD’S ROOFER AT TENANT’S EXPENSE. •COLD WATER TAP WITH SHUT-OFF VALVE SHALL BE PROVIDED FOR TENANT’S CONNECTION AT A LOCATION AS DETERMINED B LANDLORD. ONLY ONE CONNECTION TO THE LANDLORD’S MAIN IS PROVIDED AND PERMITTED. •DOMESTIC WATER IS SUPPLIED AT THE PRESSURE AVAILABLE FROM THE UTILITY MINUS PIPING PRESSURE LOSSES TO THE POINT OF CONNECTION. TENANTS REQUIREING SPECIFIC PRESSURES SHOULD TEST THE AVAILABLE PRESSURE AND INSTALL REGULATORS OR BOOSTER PUMP SYSTEMS TO MEET THEIR NEEDS. •REUSE OF ALL OR PART OF EXISTING EQUIPMENT IS SUBJECT TO THE FIELD VERIFICATION OF THE CAPACITY AND CONDITION OF THE COMPONENTS. CONTRACT DOCUMENTS SHALL PROVIDE MINIMUM PERFORMANCE PARAMETERS, REFURBISHING SPECIFICATIONS AND ESTABLISH A VERIFICATION PROCEDURE, INCLUDING A MANDATORY WRITTEN REPORT.THIS REPORT SHALL DETAIL INSPECTION AND SERVICE TO BE PERFORMED, REPAIR REPORTING PROCEDURE, ADDITIONAL RECOMMENDATIONS, AND PERFORMANCE TEST RESULTS. COPIES OF FIELD VERIFICATION REPORT SHALL BE SUBMITTED TO THE LANDLORD TO VALIDATE REUSE. 1 PIPING MATERIALS •BELOW GROUND WASTE AND VENT SHALL BE SERVICE-WEIGHT CAST IRON OR SCHEDULE 40 PVC. CONNECTIONS TO LANDLORD MAIN SHALL BE WITH CAST IRON COUPLINGS, SIMILAR TO “MG” COUPLINGS. “NO HUB” PIPING OR CONNECTIONS ARE NOT PERMITTED BELOW GROUND. •ABOVE GROUND WASTE SHALL BE SERVICE WEIGHT CAST IRON. ABOVE GROUND VENT SHALL BE CAST IRON OR SCHEDULE 40 GALVANIZED STEEL. •BELOW GROUND WATER SHALL BE TYPE “K” (SOFT) COPPER WITH NO JOINTS BELOW GROUND. •ABOVE GROUND WATER SHALL BE TYPE “L” COPPER. LOCATION OF PIPING •ALL PLUMBING EQUIPMENT SHALL BE PROPERLY SUSPENDED FROM LANDLORD’S STRUCTURE. ALL FLOOR MOUNTED EQUIPMENT (WATE HEATERS, ETC.) SHALL IMPOSE A FLOOR LOAD NO GREATER THAN 75 PSI. •NO SANITARY, VENT, WATER, OR GAS PIPING WILL BE PERMITTED WITHIN THE DEMISING WALLS. •HINGED ACCESS DOORS MUST BE INSTALLED TO PROVIDE ACCESS TO ALL PLUMBING EQUIPMENT INCLUDING BUT NOT LIMITED TO VALVES, CLEANOUTS, METERS, AND INDIRECTLY CONNECTED PIPING OR AS DESIGNATED BY THE LANDLORD. PIPING COMPONENTS •ALL BRANCH PIPING SHALL HAVE ACCESSIBLE SERVICE VALVES. •ANY AND ALL PIPING NOT REUSED, SERVING THE DEMISED PREMISES MUST BE REMOVED. •INSULATE ALL HOT WATER, COLD WATER, AND CONDENSATE DRAIN PIPING WITH PLENUM RATED MATERIALS. WATERPROOFING •ALL TOILET ROOMS REQUIRE A WATERPROOFING MEMBRANE AND FLASHING IF NOT ON GRADE. ALL FLOOR PIPE PENETRATIONS, CLEANOUTS, AND FLOOR DRAINS MUST BE SEALED WATERTIGHT, WITH MEMBRANE AND FLASHING EXTENDED INTO CLAMPING COLLAR, PER MANUFACTURER’S SPECIFICATIONS. WATER HEATER •STORAGE TYPE WATER HEATERS SHALL BE INSTALLED WITH RELIEF VALVES AND DRAIN PANS. •INSTANTANEOUS WATER HEATERS ARE ONLY ACCEPTABLE IF THEY DO NOT SUBSTANTIALLY IMPACT THE TENANT’S ELECTRICAL SERVICE. •ALL WATER HEATERS 3KW AND LARGER SHALL BE 3 PHASE. •NATURAL GAS WATER HEATERS ARE NOT PERMITTED EXCEPT WHERE WRITTEN APPROVAL FROM THE LANDLORD HAS BEEN GRANTED PRIOR TO DRAWING SUBMISSION. GAS SERVICE •GAS SERVICE MAY BE AVAILABLE TO INDIVIDUAL RETAIL SPACES.COORDINATE EXACT LOCATION OF EXISTING GAS PIPING WITH LANDLORD FIELD REPRESENTATIVE. •TENANT SHALL BE RESPONSIBLE FOR COORDINATING AVAILABLE CAPACITY, PRESSURE, SERVICE CONNECTION, METER INSTALLATION, ETC., WITH THE LANDLORD FIELD REPRESENTATIVE AND THE LOCAL UTILITY. •ALL HIGH PRESSURE AND MEDIUM PRESSURE PIPING SHALL UTILIZE ALL WELDED FITTINGS. •ROOF MOUNTED GAS PIPING SHALL BE INSTALLED ON FREE-FLOATING PREFABRICATED SUPPORTS OR EQUIPMENT SUPPORTS WITH ROLLER ASSEMBLIES. •ALL PIPING SHALL BE FINISHED WITH A RUST INHIBITIVE PRIMER, COLOR CODED FINISH, AND IDENTIFICATION LABELS. •PROVIDE DIRT LEGS AT EVERY CHANGE IN ELEVATION. VALVES AND UNIONS ARE NOT PERMITTED IN PLENUMS. •GAS METER BY TENANT AT TENANT’S EXPENSE; INSTALL PER UTILITY COMPANY REQUIREMENTS. •COORDINATE ALL ROOF WORK, PENETRATIONS AND REPAIR WITH LANDLORD’S APPROVED ROOFER. SPRINKLER PIPING TENANT CONNECTIONS •SPRINKLER PIPING SHALL BE CONNECTED AT LANDLORD MAIN, AND INSTALLED BY LANDLORD APPROVED CONTRACTOR AT THE TENANT’S EXPENSE. ‡$//6+87'2:160867%(6&+('8/(':,7+$0,1,080+285127,&(:,7+ LANDLORD REPRESENTATIVE. •FIRE PROTECTION SYSTEM SHALL BE CHARGED AND OPERATIONABLE WHEN CONTRACTOR IS NOT ON SITE. •PROVIDE VALVE WITH TAMPER SWITCH AT CONNECTION TO LANDLORD SYSTEM. SPRINKLER HEADS TO BE QUICK RESPONSE TYPE 165 F RATED. •REUSE OF ALL OR PART OF EXISTING EQUIPMENT IS SUBJECT TO THE FIELD VERIFICATION OF THE CAPACITY AND CONDITION OF THE COMPONENTS. CONTRACT DOCUMENTS SHALL PROVIDE MINIMUM PERFORMANCE PARAMETERS, REFURBISHING SPECIFICATIONS AND ESTABLISH A VERIFICATION PROCEDURE, INCLUDING A MANDATORY WRITTEN REPORT. THIS REPORT SHALL DETAIL INSPECTION AND SERVICE TO BE PERFORMED, REPAIR REPORTING PROCEDURES, ADDITIONAL RECOMMENDATIONS, AND PERFORMANCE TEST RESULTS. COPIES OF FIELD VERIFICATION REPORT SHALL BE SUBMITTED TO THE LANDLORD TO VALIDATE REUSE. 1. 3. 4. 5. 6. 7. 2. PVC PLUMBING PIPES ARE ALLOWED FOR INSTALLATION UNLESS DISAPPROVED BY THE JURISDICTION HAVING AUTHORITY. MATERIAL SCHEDULE NOTES ALL WATER PIPING SHALL BE INSULATED EITHER INSTALLED IN CONCEALED OR EXPOSED LOCATIONS. REFER TO GENERAL NOTES FOR INSULATION THICKNESS INFORMATION. BELOW GROUND WATER PIPE - TYPE 'K' COPPER WITH WROUGHT COPPER FITTINGS AND "NO-LEAD" SOLDER. ABOVE GROUND WATER PIPE - TYPE 'L' COPPER WITH WROUGHT COPPER FITTINGS AND "NO-LEAD" SOLDER. SEWER AND VENT PIPE - BELOW AND ABOVE GRADE INSIDE BUILDING SERVICE WEIGHT (HUBLESS) CAST IRON SOIL PIPE AND STAINLESS STEEL NO HUB COUPLINGS. CONDENSATE DRAIN PIPE - TYPE 'M' COPPER W/"NO-LEAD" SOLDER. INSULATE WITH 1/2" ARMAFLEX PIPE INSULATION OR EQUIVALENT. SUPPORT PIPING WITH CLEVIS OR SPLIT RING TYPE PIPE HANGERS 3/8" ALL THREAD ROD AND BEAM CLAMPS. "PLUMBERS TAPE AND WIRE" NOT PERMITTED. PLUMBING GENERAL NOTES 1.NOTE: FOR THE PURPOSE OF CLEARNESS AND LEGIBILITY, THE DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH SIZES AND LOCATIONS OF EQUIPMENT ARE DRAWN TO SCALE WHEREVER POSSIBLE, THE CONTRACTOR SHALL MAKE USE OF ALL DATA IN ALL OF THE CONTRACT DOCUMENTS AND VERIFY THIS INFORMATION PRIOR TO ORDERING, FABRICATING OR INSTALLING ANY MATERIALS. 2.THE PLUMBING CONTRACTOR SHALL PROVIDE COMPLETE INFORMATION AND COOPERATE WITH THE OTHER CONTRACTORS AND TRADES AS REQUIRED FOR THE COMPLETION AND COORDINATION OF THE PROJECT. 3.THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR ADMINISTERING ALL WARRANTIES ON EQUIPMENT WHICH THEY FURNISH AND INSTALL. 4.PROVIDE WRITTEN WARRANTY TO REPLACE ALL FAULTY MATERIALS AND/OR LABOR, AT NO COST TO TENANT, FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. WARRANTIES SHALL BEGIN ON THE DATE OF SUBSTANTIAL COMPLETION. 5.THE PLUMBING SYSTEM DESIGN, INSTALLATION AND MATERIALS SHALL CONFORM TO ALL FEDERAL, STATE AND LOCAL CODES AND AUTHORITIES HAVING JURISDICTION. 6.PLUMBING QUALITY, WEIGHTS OF MATERIALS AND ALTERNATE CONSTRUCTION METHODS SHALL CONFORM TO THE GOVERNING APPLICABLE CODE. 7.THE PLUMBING CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND LABOR (INCLUDING THE COMPLETE PLUMBING SYSTEM) FOR A PERIOD OF ONE YEAR FROM WRITTEN ACCEPTANCE BY THE TENANT. ANY DEFECTS IN MATERIALS AND OR LABOR FOUND WITHIN THE GUARANTEE PERIOD SHALL BE REMEDIED OR REPAIRED BY THIS CONTRACTOR IN A TIMELY FASHION, AT NO COST TO THE TENANT. 8.ALL PLUMBING FIXTURE LOCATIONS (WATER CLOSETS, LAVATORIES ETC.) ARE DIAGRAMMATIC AND CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR ADA COMPLIANT FIXTURES, EXACT LOCATIONS, MOUNTING HEIGHTS AND COLOR. 9.ANY DEVIATIONS FROM THE DRAWINGS OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND ENGINEER PRIOR TO INSTALLATION. 10.CONTRACTOR SHALL VISIT SITE PRIOR TO SUBMITTAL OF BID AND FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS. SUBMITTAL OF BID WILL VERIFY THAT THE CONTRACTOR HAS VISITED THE SITE. 11.PIPING SHALL BE INSTALLED PARALLEL TO BUILDING LINES AND SUPPORTED AND ANCHORED AS REQUIRED TO FACILITATE EXPANSION AND CONTRACTION. THE INSTALLATION SHALL MEET ALL CONSTRUCTION CONDITIONS AND ALLOW FOR THE INSTALLATION OF OTHER TRADES. 12.TRAP PRIMERS FOR FLOOR DRAINS AND FLOOR SINKS AND WATER HAMMER ARRESTORS TO BE INSTALLED AS PER THE GOVERNING APPLICABLE CODE AND THE LATEST EDITION OF THE AMERICAN SOCIETY OF SANITARY ENGINEERING (ASSE 1010) SIZING AND INSTALLATION REQUIREMENTS. 13.ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTORS OR OTHER EQUIPMENT SHOWN IN WALLS OR ABOVE NON-ACCESSIBLE CEILINGS SHALL BE INSTALLED BEHIND AN ACCESS PANEL. 14.ALL SERVICE WATER HEATING EQUIPMENT TO BE IN COMPLIANCE WITH THE INTERNATIONAL FUEL GAS CODE REQUIREMENTS AND LABELED AS SUCH. 15.ALL ITEMS PROJECTING THROUGH THE ROOF SHALL BE FLASHED THROUGH CURBS OR PIPE SEALS A MINIMUM OF 12" ABOVE THE ROOF. THE PIPE CURBS AND SEALS SHALL BE INSTALLED BY THE ROOFING CONTRACTOR. ENSURE THAT AMPLE BOOT OPENINGS ARE PROVIDED TO ACCOMMODATE ANY ELECTRICAL CONDUIT PENETRATIONS REQUIRED FOR POWER. 16.ALL WATER PIPING TO BE INSULATED AS PER THE INTERNATIONAL PLUMBING CODE REQUIREMENTS: PIPE SIZE INSULATION THICKNESS INSULATION VALUE 1/2" THRU 1 1/4" 1/2" R = 4.0 1-1/2" THRU 2" 1" R = 6.0 17.CONTRACTOR TO REFER TO PLUMBING FIXTURE SCHEDULE FOR INDIVIDUAL WASTE, VENT & WATER CONNECTION SIZES AT EACH PLUMBING FIXTURE. 18.ALL CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE AND LOCATED AS PER CODE REQUIREMENTS. THE CONTRACTOR SHALL COORDINATE ALL CLEAN OUT LOCATIONS WITH EQUIPMENT, MILLWORK, ETC., PRIOR TO INSTALLATION. 19.ALL PLUMBING FIXTURE VENTS TO TERMINATE A MINIMUM OF 12 INCHES FROM ANY VERTICAL SURFACE AND 10'-0" FROM OR 3'-0" ABOVE ANY MECHANICAL EQUIPMENT OUTSIDE AIR INTAKE. 20.ALL VALVES, UNIONS, ETC. TO BE SAME SIZE AS CONNECTED SUPPLY LINE UNLESS OTHERWISE NOTED ON DRAWINGS. 21.UNIONS SHALL BE PROVIDED AND INSTALLED AFTER EACH SCREW-TYPE VALVE AND PRIOR TO EQUIPMENT CONNECTIONS. 22.ALL UNDERGROUND METALLIC PIPE AND FITTINGS SHALL BE PROTECTED IN ACCORDANCE WITH THE SOILS ENGINEER'S RECOMMENDATIONS. 23.NO PIPING SHALL BE DIRECTLY EMBEDDED IN CONCRETE, MASONRY WALLS, OR CONCRETE FOOTINGS. 24.THE PLUMBING CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS FOR ALL POINTS OF CONNECTION WITH THE GENERAL CONTRACTOR AND OTHER TRADES PRIOR TO START OF WORK. 25.VERIFY EXACT LOCATIONS, DEPTH AND SIZE OF ALL PIPING TO WHICH CONNECTIONS ARE REQUIRED. COORDINATE ALL CONNECTIONS WITH SITE CONDITIONS AND SITE UTILITY CONTRACTOR/ REPRESENTATIVE. 26.ALL HORIZONTAL PIPING LINES EXTENDED AND CONNECTED TO EQUIPMENT SHALL BE RUN AT THE HIGHEST POSSIBLE ELEVATIONS AND NOT LESS THAN 6" ABOVE THE FLOOR TO PROVIDE CLEARANCE FOR CLEANING. 27.ALL CUTTING OF EXISTING PAVING, WALKS AND/OR FLOORS SHALL UTILIZE MACHINE SAW CUTTING EQUIPMENT. HOLES FOR PIPES IN CONCRETE WALLS OR FLOORS SHALL UTILIZE CORE DRILLING EQUIPMENT. COORDINATE WITH ARCHITECTURAL DETAILS FOR FLOOR CUTTING AND PATCHING. 28.THE PLUMBING CONTRACTOR IS TO PROVIDE ALL ADDITIONAL STEEL, HANGER MATERIALS, RODS AND CLAMPS AS REQUIRED FOR COORDINATION WITH WORK OF OTHER TRADES. 29.PIPING LAYOUT IS SCHEMATIC ONLY, EXACT ROUTING AND INSTALLATION OF PIPES TO BE COORDINATED WITH THE BUILDING STRUCTURE AND THE WORK OF OTHER CONTRACTORS. 30.NO LIQUID TRANSMISSION PLUMBING PIPING SHALL BE INSTALLED ABOVE ELECTRICAL SWITCH GEAR, EQUIPMENT, OR PANELS. MAKE ADJUSTMENTS NECESSARY TO REROUTE PIPING FOR ACTUAL INSTALLATION OF ELECTRIC EQUIPMENT. 31.WHENEVER FOUNDATION WALLS, EXTERIOR WALLS, ROOFS, ETC. ARE PENETRATED FOR THE INSTALLATION OF PLUMBING SYSTEMS, THEY SHALL BE PATCHED TO MATCH EXISTING CONSTRUCTION AND SEALED WEATHER TIGHT. 32.PLUMBING CONTRACTOR SHALL BE ON SITE AND PRESENT AT THE DATE OF STORE TURNOVER. 1CLEANOUT DETAILS SCALE: NONE 2PIPE HANGER DETAIL SCALE: NONE3VENT THRU ROOF DETAIL SCALE: NONE 3" MINIMUM SEWER LATERAL SIZE ADJUSTABLE TYPE CLEANOUT 18" x 18" x 4" CONCRETE PAD, 1" ABV. FIN. GRADE VARIES FINISHED GRADE DOUBLE CLEANOUT 1/8 BEND FULL SIZE, 3" MAX. (TYP) ADJUSTING COLLAR COVER CLEANOUT PLUG AND BODY. SEE SPECS FINISHED FLOOR FLOOR CLEANOUT FLOW PLUG IF END OF LINE (TYP) RISER (LENGTH AS REQUIRED) CLEANOUT PLUG STAINLESS STEEL ACCESS COVER WITH VANDAL PROOF COUNTERSUNK SCREW MAY EXTEND AS WASTE OR VENT FINISHED FLOOR 45° WYE FITTING (TYP) CLEANOUT TEE WALL CLEANOUT I-BEAM OR JOISTS ANCHOR - PER NFPA 3/8" ALL-THREAD ROD FOR <=4" PIPE. FOR LARGER PIPE SIZES SEE NFPA 13. HANGER - GRINNEL FIG. 69 ON INSULATED PIPE. PROVIDE PIPE SUPPORT SHIELD. ALL VENTS INSIDE ROOF WELL SHALL EXTEND UP TO 1" ABOVE THE PARAPET ANCHOR PIPE TO ROOF DECK WITH U-BOLT AROUND PIPE AND ANGLE IRON WELDED OR SCREWED TO ROOF DECK OR JOIST. MIN. 12" BELOW ROOF NO-HUB PIPE CONNECTORS ON CAST IRON PIPE OR BELL AND SPIGOT IF PVC CORE DRILL ROOF OR PROVIDE SLEEVE IF REQ'D. BY TYPE OF ROOF DECK. PROVIDE FIRE STOP SEAL BETWEEN PIPE & SLEEVE PROVIDE PIPE INCREASER IF OR WHERE THE PLUMBING CODE REQUIRES A MINIMUM 3" VENT THRU ROOF REFER TO PLANS FOR VTR PIPE SIZES AND LOCATIONS. LOCATE VTR MIN. THREE FEET FROM PROPERTY LINE, OR TEN FEET HORIZONTAL OR THREE FEET VERTICAL ABOVE ANY BUILDING OPENING OR FRESH AIR INTAKE, OR ONE FOOT FROM ANY VERTICAL SURFACE. LOCATE VTR MINIMUM 18" FROM PARAPET, EXPANSION JOINT, EQUIPMENT CURB, ETC. OFFSET IN CEILING SPACE WHERE REQUIRED TO MEET THESE CONDITIONS FLASHING & COUNTERFLASHING OF VENT THRU ROOF IS BY ROOFING CONTRACTOR. PLUMBING CONTRACTOR TO COORDINATE INSTALLATION ROOF DECK ROOF INSULATION P2.0 PLUMBING SCHEDULES /LC KF 4TANKLESS HOT WATER HEATER DETAIL SCALE: NONE PLUMBING LEGEND HOSE BIBB GALLONS PER MINUTE GALLONS PER HOUR HORSEPOWER POUNDS PER SQUARE INCH ACCESS PANEL WITH FLOOR CEILING ABOVE BELOW UNDERGROUND DOWN CONTINUE TYPICAL FRONT OF HOUSE BACK OF HOUSE AMERICAN DISABILITIES ACT ABOVE FINISH FLOOR BELOW FINISH FLOORB.F.F. A.F.F. A.D.A. BOH FOH TYP. CONT. DN UG BEL ABV CLG FLR W/ AP PSI HP GPH GPM FLOOR SINK (COORDINATE GRATE REQS) FLOOR DRAIN (COORDINATE GRATE REQS) VENT TO ROOF POINT OF CONNECTION BALANCING VALVE CHECK VALVE SHUT-OFF VALVE, NORMALLY CLOSED SHUT-OFF VALVE, NORMALLY OPEN SHUT-OFF VALVE CLEANOUT, WALL OR PIPE DOUBLE CLEANOUT FLOOR CLEANOUT PIPE DOWN TEE DOWN PIPE UP HOT WATER FILTERED WATER COLD WATER CONDENSATE DRAIN VENT GREASE WASTE SOIL OR WASTE (BELOW GRADE)S OR W GW V CD CW FW HW UP FW CD GW SAN DN. DN. FCO DCO CO SOV NO NC SOV SOV C.V. B.V. POC VTR FD FS HB SYMBOL ABBREV.DESCRIPTION WATER METER GATE VALVES BALL VALVES TEMPERATURE PRESSURE-RELIEF VALVE VACUUM RELIEF VALVE TRAP PRIMER MIXING VALVE WATER HAMMER ARRESTERS BACK-FLOW PREVENTER (BFP) EXPANSION TANK PLUMBING FIXTURE SCHEDULE MARK FIXTURE ROUGH-IN-SIZE DESCRIPTION/REMARKS S/W V CW HW WC-1 WATER CLOSET (ADA) LAV-1 LAVATORY (ADA) FCO FLOOR CLEANOUT ZURN #1400 ADJUSTABLE FLOOR CLEANOUT, DURA-COATED CAST IRON BODY, GAS AND WATER TIGHT TAPERED THREAD PLUG, AND 5"Ø ROUND POLISHED NICKEL BRONZE TOP. LINE SIZED --- SS-1 SERVICE SINK WH-1 WATER HEATER --3/4"3/4" DF-1 ELECTRIC WATER COOLER --1/2"- HI-1 HAIR INTERCEPTOR 1 1/2"2"-- PB-1 PET BAY FAUCET AND DRAIN 2"1 1/2"1/2"1/2" WALL CLEANOUT JOSAM SERIES 58910 TEE CLEANOUT FOR USE IN WALLS. PROVIDE WITH JOSAM SERIES 58600-VP SECURE WALL ACCESS COVER WITH VANDAL-PROOF SCREWS. SEE PLUMBING PLAN AND ISOMETRICS FOR SIZE. FLOOR DRAIN ZURN MODEL Z453B-P FLOOR DRAIN WITH "TYPE B" STRAINER AND TRAP PRIMER CONNECTION.FD-1 WCO LINE SIZED --- 2"1/2"3"1/2" HUB DRAINHD-1 2"1 1/2"--ZURN MODEL # Z1019 CAST IRON DEEP SEAL P-TRAP WITH FUNNEL. NO-HUB OUTLET AND BRASS GASKETED CLEANOUT PLUG. COMPLAS/ENDURA #393243AW PVC INLINE DRAIN STRAINER, WITH DRUM TRAP STRAINER, FLANGED AND GASKETED CLEANOUT COVER WITH RAISER SQUARE HEAD. ALL PET BAYS SUPPLIED BY G.C. WITH MIXING VALVES SET AT MAXIMUM 110F. THROUGH AAPEX CREATIONS INC. INSTALLATION TO BE DONE BY VENDOR AAPEX CREATIONS INC. G.C. TO COORDINATE. FINAL CONNECTIONS BY AAPEX CREATIONS INC. CONTRACTOR TO FURNISH AND INSTALL AN ASSE 1070 APPROVED TEMPERATURE/MIXING VALVE AT EACH DOG WASH STATION LIMITING TEMPERATURE OF HOT WATER TO 110F. CONTACT: PAUL STEWART - PHONE: # 267- 932-8251 - EMAIL: contact@aapex.us WATER HAMMER ARRESTERS: PROVIDE ON HOT AND COLD WATER BRANCHES TO FIXTURES, J. R. SMITH HYDROTROL MODEL 5020 FOR UP TO 60 FIXTURE UNITS. WATER HAMMER ARRESTERS SHALL CONFORM TO ASSE 1010. WATER HAMMER ARRESTOR ---- BFP --BACKFLOW PREVENTER -- BACKFLOW PREVENTER: WATTS SERIES LF909 DOUBLE CHECK VALVE ASSEMBLY BACKFLOW PREVENTER. LINE SIZE 1/2" TO 2" TO MATCH INLET WATER LINE SIZE. DOUBLE CHECK BACKFLOW PREVENTER SHALL CONFORM TO ASSE 1013 AND AWWA C511.92 NAVIEN # NPE-240A PROPANE GAS FIRED WATER HEATER, 199,900 BTUH INPUT, INSTANTANEOUS TYPE HEATER, 11.2 GPM, COMFORTFLOW/TECHNOLOGY WITH BUILT IN 0.5 GALLON BUFFER TANK AND RECIRCULATION PUMP. , REMOTE ELECTRONIC CONTROLS AND INTEGRAL DIAGNOSTIC. (THE CONTACT TO PURCHASE THE NAVIEN UNITS: Arun Mathews, arunmathews@mytanklesswaterheaterstore.com PHONE 630-200-7310) 2"1/2"3"1/2" 3"2"1/2"- 1 1/2"2"1/2"1/2" ELKAY #EZSTL8LC BARRIER FREE DUAL STATION WATER COOLER, 8.0GPH, 120V, FRONT AND SIDE PUSH BARS, CHROME PLATED CAST BRASS P-TRAP W/ CLEANOUT, AND FLOOR MOUNTED CARRIER. MUSTEE 63M - FLOOR MOUNTED SINK 24"X24"X10". SERVICE FAUCET MODEL # 63.600A, AND HOSE AND HOSE HOLDER MODEL # 65.700. THE MUSTEE WALL GUARDS MAY BE USED INSTEAD OF FRP. KOHLER, # K-3999 - HIGHLINE- CLASS FIVE - VITREOUS CHINA, FLOOR MOUNTED, FLOOR OUTLET, WITH THE STRONGHOLD K-4731-C TOILET SEAT, KOHLER, #K-1997-4-0 (WHITE), WALL MOUNT, FAUCET: MOEN CHATEAU L4621. WITH WATTS LFMMV HOT WATER TEMPERATURE CONTROL VALVE THAT CONFORMS TO ASSE 1070 STANDARDS. DATE WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS WILL NOT BE APPROVED FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS. CONTRACTOR'S NOTES: ISSUE DATE REVISION LOCATION: PROJECT INFORMATION: TITLE: SHEET NUMBER: ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): 461 FROM ROAD PARAMUS, NJ 07652 973.253.9393 TEL 973.253.9390 FAX WWW.SARGARCH.COM 02/14/17 ISSUE TO CLIENT, LL, HOMELAND SECURITY DATE: 02/14/17 RANGELINE CROSSING SHOPPING CENTER 1356 S. RANGELINE RD. SPACE 1370 CARMEL, IN 46032 AREA: 2,988 SQ. FT. DRAWN BY: DT REVIEWED BY: ECB PROJECT NUMBER: 1621-17 02/23/17 LL COMMENTS 02/23/17 CLIENT / LL Kenneth A. Fuller, P.E. 153 East Main St. Rockaway, NJ 07866 Tel: 973-784-4258 kfullerpe@msn.com CONTRACTOR TO MOUNT BOTTOM OF WATER HEATER AT 7'-0” AFF . EXPANSION TANK "ET1" ASME RATED & APPROVED. AMTROL MODEL: ST-5-C HANG TANK PER MANUFACTURER'S RECOMMENDATIONS. WATER HEATER CONTROLLER INTEGRAL TO WATER HEATER . WALL MOUNTED INSTANTANEOUS WATER HEATER WITH CONTROLLER . COMBUSTION AIR INTAKE & EXHAUST PIPING TO OUTSIDE BUILDING. (REFER TO HVAC PLANS FOR ROUTING MATERIALS & TERMINATION DETAILS). FACTORY FURNISHED CONDENSATE TRAP. PROVIDE PVC PIPING FROM COMBUSTION AIR EXHAUST PIPING AND TO ACID NEUTRALIZER KIT AS INDICATED. 120VAC ELECTRICAL POWER TO WATER HEATER. (COORDINATE POWER REQUIREMENTS WITH ELECTRICAL CONTRACTOR). WATER HEATER # 1 3/4" CW N.O. N.O. N.O.1-1/4" GASET1 1-1/4" GAS AERCO MODEL 89025-1 CONDENSATE NEUTRALIZER KIT. 3/4" HW 110°F RETURN 3/4" HW 110°F SUPPLY SEDIMENT TRAP CAP CONTRACTOR TO MOUNT BOTTOM OF WATER HEATER AT 7'-0” N.O. 2" 3" W.C.O. 3/4" 2" 6 PROVIDE DRAIN WITH AIR GAP FOR BACK-FLOW PREVENTER. DRAIN SHALL DISCHARGE INTO THE SANITARY LINE. HI-1 PB-1 12 8 4 12 83" 2 3 3/4" 3/4" 3/4" 16 DF-1 15 1/2" 3" 2" PROVIDE DRAIN WITH AIR GAP FOR BACK-FLOW PREVENTER. DRAIN SHALL DISCHARGE INTO THE SANITARY LINE. 11 3/4" 3" W.C.O. 2" WC-1 BACK-FLOW PREVENTER (IF REQUIRED) WATER METER (IF REQUIRED) SHUT OFF VALVE 3/4" 2" 3" F.C.O. HI-1 PB-1 4 SS-1 7 1/2" 2" 13 5 3" 3" WH-1 3"WM 7 14 1/2" 2" 9 LAV-1 2" 1/2" 1-1/2" SHUT OFF VALVE 1/2" 3/4" 3/4" 3/4" 3" 2" 1-1/2" 2" 1-1/2" 1 2" 3" 3" 1ISOMETRIC RISER DIAGRAM SCALE: NONE P3.0 RISER DIAGRAM /LC 2DOG WASH PLUMBING AND ELECTRICAL INSTALLATION REQUIREMENTS SCALE: NONE KF KEY NOTES ALL PET BAY FAUCET (T &S BRASS B-0669-PCL) ARE PROVIDED AND INSTALLED BY VENDOR. WATER HEATER SHALL BE WALL MOUNTED AS SHOWN ON PLAN. REFER TO INSTALLATION DETAIL ON SHEET P2.0. CONNECT 3/4" CW AND HW LINES TO MODULAR WASH STATION WATER HOOKUPS. VERIFY EXACT LOCATION WITH MANUFACTURER IN THE FIELD. INSTALL HOT AND COLD WATER SHUTOFF VALVES. EXTEND 1/2" HW & CW TO WASHING MACHINE AND SERVICE SINK. 1 2 3 4 5 6 7 8 ALL PET BAYS SUPPLIED BY T.G.C. WITH MIXING VALVES SET AT MAXIMUM 110F. THROUGH AAPEX CREATIONS INC. INSTALLATION TO BE DONE BY VENDOR AAPEX CREATIONS INC. T.G.C. TO COORDINATE. FINAL CONNECTIONS BY T.G.C. PROVIDE BACKFLOW PROTECTION. EXTEND NEW 3/4" CW TO EXISTING CW MAIN OF ADEQUATE SIZE. VERIFY EXACT LOCATION IN FIELD PRIOR TO BID. 3" SANITARY SEWER PIPING TO CONNECT TO EXISTING SANITARY MAIN. VERIFY EXACT LOCATION AND POINT OF CONNECTION IN FIELD PRIOR TO BID. CONNECT 3" DRAIN LINE FROM EACH MODULAR WASH STATION SANITARY HOOKUPS TO NEW 3" SANITARY SEWER LINE. VERIFY EXACT LOCATION WITH MANUFACTURER IN THE FIELD. ROUTE DRAIN LINES FROM WATER HEATER TO INDIRECT TERMINATION AT SERVICE SINK. PROVIDE 2" SANITARY AND 1 1/2" VENT CONNECTION FOR WASHING MACHINE. 10 11 12 13 14 PROVIDE 2" SANITARY AND 1 1/2" VENT CONNECTION FOR HI/LO DRINKING FOUNTAIN. 15 EXTEND 1/2" CW TO HI/LO DRINKING FOUNTAIN.16 GENERAL CONTRACTOR FURNISHED AND INSTALLED WATTS LFMMV HOT WATER TEMPERATURE CONTROL VALVE AT EACH LAVATORY. 9FOR ADDITIONAL INSTALLATION INFORMATION AND VIDEOS, PLEASE REFER TO HTTP://AAPEX.US. 2 " VENT LINE TO CONNECT TO EXISTING VENT LINE. VERIFY EXACT LOCATION IN FIELD PRIOR TO BID. DATE WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. THE CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, THE CONTRACT TO THE TENANT'S REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. CHANGE ORDERS WILL NOT BE APPROVED FOR ISSUES ARISING FROM THE FIELD CONDITIONS OR CONFLICTS BETWEEN THE PLANS AND THE EXISTING CONDITIONS. CONTRACTOR'S NOTES: ISSUE DATE REVISION LOCATION: PROJECT INFORMATION: TITLE: SHEET NUMBER: ARCHITECTURAL SEAL: CONSULTANTS (ENGINEER): 461 FROM ROAD PARAMUS, NJ 07652 973.253.9393 TEL 973.253.9390 FAX WWW.SARGARCH.COM 02/14/17 ISSUE TO CLIENT, LL, HOMELAND SECURITY DATE: 02/14/17 RANGELINE CROSSING SHOPPING CENTER 1356 S. RANGELINE RD. SPACE 1370 CARMEL, IN 46032 AREA: 2,988 SQ. FT. DRAWN BY: DT REVIEWED BY: ECB PROJECT NUMBER: 1621-17 02/23/17 LL COMMENTS 02/23/17 CLIENT / LL Kenneth A. Fuller, P.E. 153 East Main St. Rockaway, NJ 07866 Tel: 973-784-4258 kfullerpe@msn.com