Loading...
HomeMy WebLinkAbout17040059 Building PlansFCC DEVELOPMENTMERIDIAN N MEDICAL BUILDINGSUITE 100 BUILD-OUT13590-B NORTH MERIDIAN STREETCARMEL, IN 46032VICINITY MAPPROJECT TEAMGENERALG000 COVER SHEETG001 LIFE SAFETY PLANG002 ANSI 117.1 ACCESSIBILITY DETAILSG003 ANSI 117.1 ACCESSIBILITY DETAILSINTERIOR ARCHITECTUREIA001 GENERAL NOTES AND SYMBOLSIA101 DEMOLITION PLAN, CONSTRUCTION PLAN, AND FINISH SCHEDULEIA201 REFLECTED CEILING AND ELECTRICAL/DATA PLANS (LOCATION ONLY)IA251 MECHANICAL / PLUMBING PLANKEY PLANOWNERFCC DEVELOPMENTFRANK COSMAS - PRESIDENT621 NORTHWOOD DRIVECARMEL, IN 46033PHONE: 317-846-5800FAX: 317-848-8838EMAIL: FCOSMAS@GMAIL.COMDRAWING INDEXINTERIOR DESIGNERMITSCH DESIGNERIN SANFORD - PROJECT MANAGER200 SOUTH RANGELINE ROAD, STE 213CARMEL, IN 46032PHONE: 317-573-2222FAX: 317-573-2230EMAIL: ESANFORD@MITSCHDESIGN.COMINTERIOR DESIGNERMITSCH DESIGNCOURTNEY ROESSLER - PROJECT DESIGNER200 SOUTH RANGELINE ROAD, STE 213CARMEL, IN 46032PHONE: 317-573-2222FAX: 317-573-2230EMAIL: CROESSLER@MITSCHDESIGN.COMARCHITECTMITSCH DESIGNSTU SHADE - ARCHITECT200 SOUTH RANGELINE ROAD, STE 213CARMEL, IN 46032PHONE: 317-573-2222FAX: 317-573-2230EMAIL: SSHADE@MITSCHDESIGN.COMG000COVERSHEETAS NOTEDALL IDEAS, DESIGNS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY, AND THE PROPERTY OF MITSCH DESIGN. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. ALL RIGHTS RESERVED, EXCEPT FOR USES EXPRESSLY PERMITTED IN WRITING. FCC DEVELOPMENT MERIDIAN N MEDICAL BUILDING SUITE 100 BUILD-OUT 13590-B NORTH MERIDIAN ST CARMEL, IN 46032 STATE SUBMITTAL SETCRES17023PRELIMINARY SET PRICING SET STATE SUBMITTAL SET CONSTRUCTION SET 200 s rangeline roadsuite 213carmel, indiana 46032ph 317.573.2222fx 317.573.2230www.mitschdesign.comTAA TU SA R T R. H S EDD R EITCH C G001LIFE SAFETY PLANAS NOTEDLIFE SAFETY LEGENDFIRE EXTINGUISHER AND CABINETFIRE EXTINGUISHER AND WALL BRACKETFEBFEBNOTE: COORDINATE FINAL FIRE EXTINGUISHER LOCATIONS WITH LOCAL FIRE CHIEFDENOTES DIRECTION OF EGRESSALL IDEAS, DESIGNS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY, AND THE PROPERTY OF MITSCH DESIGN. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. ALL RIGHTS RESERVED, EXCEPT FOR USES EXPRESSLY PERMITTED IN WRITING. FCC DEVELOPMENT MERIDIAN N MEDICAL BUILDING SUITE 100 BUILD-OUT 13590-B NORTH MERIDIAN ST CARMEL, IN 46032 STATE SUBMITTAL SETCRES17023PRELIMINARY SET PRICING SET STATE SUBMITTAL SET CONSTRUCTION SET 200 s rangeline roadsuite 213carmel, indiana 46032ph 317.573.2222fx 317.573.2230www.mitschdesign.comTAA TU SA R T R. H S EDD R EITCH C CODE ANALYSISEXISTING BUILDING AREA1692 SQ FTEXIST. CONSTRUCTION TYPEVBALLOWABLE AREA PER CODERESTROOMS REQUIREDALL RESTROOMS ARE EXISTING IN COMMONAREAMOP SINK - EXISTING IN BUILDINGWATER COOLER - BOTTLED WATER PROVIDEDEXIST OCCUPANCY TYPEB - BUSINESSOCCUPANCY1692 / 100 - 17 PER TABLE 1004.1.2EXITS REQUIRED1 PER TABLE 1021.2 LESS THAN 49 POCCUPANTSDEAD END CORRIDORSNONE - BUILDINGS REQUIRING ONLY ONE EXITEGRESS DOOR HARDWAREEGRESS DOOR SWINGNO REQUIREMENT PER 1008.1.10NO REQUIREMENT PER 1008.1.2COMMON PATH OF EGRESS TRAVELPER TABLE 1014.3STAIRSEXISTING - NOT IN PROPOSED AREA OF WORK20,292 SFPER TABLE 503PROPOSED CONSTRUCTION TYPEVBPROPOSED OCCUPANCY TYPEPROPOSED CONSTRUCTION AREAB - BUSINESSALLOWABLE AREA INCREASEGROSS AREA CALCULATIONASSEMBLY AREASFIRE PROTECTIONNONETOTAL OCCUPANT LOADFULLY SPRINKLEDEXIT SEPARATIONDNAEXITS PROVIDED1EXIT ACCESS TRAVEL DISTANCEPER TABLE 1016.2DNA39 OCCUPANTS ALL IDEAS, DESIGNS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY, AND THE PROPERTY OF MITSCH DESIGN. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. ALL RIGHTS RESERVED, EXCEPT FOR USES EXPRESSLY PERMITTED IN WRITING. FCC DEVELOPMENT MERIDIAN N MEDICAL BUILDING SUITE 100 BUILD-OUT 13590-B NORTH MERIDIAN ST CARMEL, IN 46032 STATE SUBMITTAL SETCRES17023PRELIMINARY SET PRICING SET STATE SUBMITTAL SET CONSTRUCTION SET 200 s rangeline roadsuite 213carmel, indiana 46032ph 317.573.2222fx 317.573.2230www.mitschdesign.comTAA TU SA R T R. H S EDD R EITCH CG002ANSI 117.1 ACCESIBILITY DETAILSAS NOTED15 inch min 48 inch max 48 inches max 44 inches max >20-25 inches max20 inch max10 inch max48 inch max 15 inch min10" max48 max 34 max 34" max 46" max> 10"-24" max32 inches min32 inches min32 inches minƒ60 inch min 18 inch min48 inch min12 inch min*36 inch min60 inch min 42 inch min54 inch min 42 inch min**22 inch min48 inch min*24 inch min* Where both closer and latch are provided24 inch min42 inch min** 54" min. where closer and is provided* 48" min. where closer is provided48 inches min48 inch min22 inch min42 inch min 24 inch min42 inch min 36 inches min*48 minimum if closer is provided12 inch min**If both closer and latch are provided** 48" min. where both closer and latch are provided42 inch min48 inch min 60 inch min Door WidthDoor Width48 inch min60 inch min 60 inch min60 inch minDoor WidthALL IDEAS, DESIGNS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY, AND THE PROPERTY OF MITSCH DESIGN. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. ALL RIGHTS RESERVED, EXCEPT FOR USES EXPRESSLY PERMITTED IN WRITING. FCC DEVELOPMENT MERIDIAN N MEDICAL BUILDING SUITE 100 BUILD-OUT 13590-B NORTH MERIDIAN ST CARMEL, IN 46032 STATE SUBMITTAL SETCRES17023PRELIMINARY SET PRICING SET STATE SUBMITTAL SET CONSTRUCTION SET 200 s rangeline roadsuite 213carmel, indiana 46032ph 317.573.2222fx 317.573.2230www.mitschdesign.comTAA TU SA R T R. H S EDD R EITCH C ALL IDEAS, DESIGNS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY, AND THE PROPERTY OF MITSCH DESIGN. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. ALL RIGHTS RESERVED, EXCEPT FOR USES EXPRESSLY PERMITTED IN WRITING. FCC DEVELOPMENT MERIDIAN N MEDICAL BUILDING SUITE 100 BUILD-OUT 13590-B NORTH MERIDIAN ST CARMEL, IN 46032 STATE SUBMITTAL SETCRES17023PRELIMINARY SET PRICING SET STATE SUBMITTAL SET CONSTRUCTION SET 200 s rangeline roadsuite 213carmel, indiana 46032ph 317.573.2222fx 317.573.2230www.mitschdesign.comTAA TU SA R T R. H S EDD R EITCH CG003ANSI 117.1 ACCESIBILITY DETAILSAS NOTED36 inches min 48 inches min24 inches max32 inches min32 inches min36 inches min 24 inches max60 inch min24 inch min36 inch min 36 inch min12 inch min12 inch min60 inch minimumbasearm arm SINKC.O.2"V2" WASTE TOMAIN BLDG. WASTEIA001GENERAL NOTES,WALL, & DOOR TYPESAS NOTEDALL WORK IS TO BE COMPLETED IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES,RULES, REGULATIONS AND STANDARDS, INCLUDING, BUT NOT LIMITED TO: THE INDIANA BUILDINGCODE, THE INDIANA CODES, THE INDIANA FIRE CODES, THE AMERICANS WITH DISABILITIES ACT (ADA),INTERNATIONAL BUILDING CODE, AND APPLICABLE TRADE STANDARDS. ALL APPLICABLE RULES ANDREGULATIONS ARE TO BE THE MOST CURRENT ADOPTED EDITIONS.THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ALL CONDITIONS AND DIMENSIONS PRIORTO THE START OF WORK. REPORT ANY DISCREPANCIES TO THE ARCHITECT/DESIGNER IMMEDIATELY.THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL STATE AND LOCAL PERMITS REQUIRED FORCOMPLETION OF THIS PROJECT.ALL WORK IS TO BE COORDINATED BY THE GENERAL CONTRACTOR TO ASSURE ADEQUATE FIT, FINISH,SYSTEM OPERATION, AND FULL COMPLETION OF THE WORK, INCLUDING SERVICE REQUIREMENTS OFTHE OWNERS F.F.E.ALL DIMENSIONS ARE SHOWN ON THE DRAWINGS. ANY DIMENSIONS NOT SHOWN OR DEEMEDQUESTIONABLE ARE TO BE VERIFIED WITH THE ARCHITECT/DESIGNER. DO NOT SCALE DIMENSIONSON THE DRAWINGS. ALL DIMENSIONS ARE TO THE FACE OF GYPSUM BOARD, MASONRY/CONCRETEWALLS, OR CENTERLINE OF COLUMNS UNLESS NOTED OTHERWISE.CONTRACTOR IS TO SIGN EACH SHOP DRAWING SUBMITTAL HAS BEEN REVIEWED, APPROVED, ANDTHAT THE CONTRACTOR COORDINATION HAS BEEN PERFORMED.DURING THE ENTIRE PERIOD OF CONSTRUCTION, ALL EXISTING EXITS, EXIT LIGHTING, FIREPROTECTIVE DEVICES, AND ALARMS SHALL BE CONTINUOUSLY MAINTAINED.FINISHED DOOR OPENINGS IN NEW PARTITIONS SHALL BE SET 4" FROM ADJACENT PERPENDICULARPARTITIONS, UNLESS OTHERWISE NOTED.ALL FINISH CARPENTRY IS TO BE COMPLETED IN STRICT ACCORDANCE WITH A.W.I. STANDARDS,PREMIUM GRADE.ALL FIRE EXTINGUISHER CABINET LOCATIONS ARE TO BE COORDINATED WITH THE CONTRACTOR,DESIGNER AND THE LOCAL FIRE OFFICIALS PRIOR TO INSTALLATION.CONTRACTOR(S) SHALL PROVIDE ALL NECESSARY LABOR, MATERIALS, AND EQUIPMENT FOR THEWORK IN THESE DOCUMENTS, UNLESS CLEARLY NOTED "NOT IN CONTRACT" (N.I.C.). EXISTING WORKADJACENT TO OR IN THE AREA OF NEW WORK SHALL BE PROTECTED BY ALL SUITABLE MEANSNECESSARY TO PREVENT OR MINIMIZE DAMAGE. WHERE EXISTING WORK IS TO BE REMOVED ORALTERED, RESTORE ADJACENT FINISH TO ORIGINAL CONDITION. EXTEND/REFINISH ALL FRAMES,BASE, AND TRIM WHERE CUTTING HAS EXPOSED ANY UNFINISHED SURFACES. REPAIR ANY DAMAGETO EXISTING WORK AND RESTORE TO ORIGINAL CONDITION.CONTRACTORS SHALL KEEP WORK AREAS AND ADJACENT PUBLIC CORRIDORS AND FACILITIES FREEOF DEBRIS. MATERIALS STORED ON SITE ARE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALLBE STORED IN A LOCATION APPROVED BY THE LANDLORD.ALL PLUMBING ITEMS AND/OR EQUIPMENT ITEMS ARE TO BE COORDINATED AND VERIFIED WITHINTERIOR ELEVATIONS PRIOR TO ROUGH-IN. ANY DISCREPANCIES SHALL BE COORDINATED WITH THEDESIGNER.COORDINATED WITH OWNER AND FACILITY STAFF PROJECT PHASING TO MINIMIZE DISRUPTION OFEXISTING FACILITY SERVICES. PHASING TO INCLUDE ASSURANCE FOR CLEAN AIRFLOW, WRITTENNOTIFICATION OF INTERRUPTIONS, AND COMMUNICATION AUTHORITY. CONTRACTOR, OWNER, ANDFACILITY STAFF TO PLAN FOR PROCEDURES ON THE EFFECTS OF NOISE AND VIBRATION ON HUMANHEALTH AND SAFETY. THE RENOVATED AREAS SHALL BE ISOLATED FROM THE OCCUPIED AREASDURING ALL PHASES OF CONSTRUCTION USING AIRTIGHT BARRIERS, AND EXHAUST AIR FLOW SHALLBE SUFFICIENT TO MAINTAIN NEGATIVE AIR PRESSURE IN THE CONSTRUCTION ZONE.SUBMIT THE REQUIRED NUMBER OF SUBMITTALS FOR DESIGNER REVIEW AND APPROVAL PLUS ONEEXTRA COPY FOR DESIGNERS RECORDS.CBARCHITECTURAL NOTESASEE SCHEDSEE SCHEDSEE SCHED TYPE #1HOLLOW METALSEE SCHEDTYPE #1SOLID WOODDOORSEE SCHED TYPE #2SOLID WOODDOOR, GLASSKITSEE SCHED DEFGHIJLMN#1 PASSAGE LATCH1 LEVER HANDLE PASSAGE LATCH SET1 DOOR STOP3 SILENCERS#2 ENTRY/EXIT OR OFFICE LOCKSET1 LEVER HANDLE OFFICE LOCKSET1 DOOR STOP3 SILENCERSDOOR TYPESFRAME TYPESHARDWARE LEGENDPROVIDE FIRE DAMPERS AT FIRE-RATED PARTITIONS AS REQUIRED PER APPLICABLE BUILDINGCODES.CEILING IN ALL AREAS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'SSPECIFICATIONS, AND ALL APPLICABLE BUILDING CODES.MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DUCTWORK, SUPPLY AND RETURN AIRAND THERMOSTATS. COORDINATE ALL ELEMENTS OF THE HVAC SYSTEM TO PROVIDE A COMPLETELYBALANCED AND EFFICIENT HEATING AND COOLING SYSTEM.HVAC THERMOSTAT CONTROL FOR ALL ROOMS SHALL BE LOCATED WITHIN DEMISED SUITE. VERIFYAND REWORK EXISTING DUCTWORK AND THERMOSTATS AS REQUIRED.MECHANICAL CONTRACTOR SHALL VERIFY WORKING CONDITION OF ALL EXITING THERMOSTATS, VAVBOXES, EXHAUST FANS, AND ANY OTHER DEVICE DIRECTLY RELATED TO THE HVAC SYSTEM.CONTRACTOR TO NOTIFY ENGINEER/DESIGNER IMMEDIATELY UPON DISCOVERY OF DEFECTIVEDEVICE.CBREFLECTED CEILING NOTESADKTHE ELECTRICAL CONTRACTOR IS TO PROVIDE ALL REQUIRED LABOR, MATERIALS, EQUIPMENT, ANDCONTRACTORS SERVICES NECESSARY TO COMPLETE INSTALLATION OF SYSTEMS REQUIRED IN FULLCONFORMITY WITH APPLICABLE CODES AND ORDINANCES. THE FINISHED JOB SHALL BE FUNCTIONALAND COMPLETE IN EVERY DETAIL INCLUDING ANY AND ALL SUCH ITEMS FOR A COMPLETE SYSTEM.ALL MATERIALS AND WORKMANSHIP SHALL MEET ALL APPLICABLE STATE AND LOCAL CODES,ORDINANCES, UTILITY COMPANY REGULATIONS AND NATIONALLY ACCEPTED CODES AND STANDARDS.THE ELECTRICAL CONTRACTOR WILL BEAR ALL COSTS ARISING IN CORRECTING ANY NONCOMPLIANCE WITH THE REQUIREMENTS OF APPLICABLE CODES.CONTRACTOR TO SUPPLY AND INSTALL ALL ELECTRICAL WIRING, INCLUDING RUNS FROM JUNCTIONBOX TO INDIVIDUAL WORKSTATION UNITS. CONTRACTOR TO SUPPLY PLENUM RATED BOXES ANDPULLS AS REQUIRED TO ACCOMMODATE TENANT'S TELEPHONE, DATA AND SECURITY DEVICES.ELECTRICAL NOTESCBAOETHE GENERAL CONTRACTOR SHALL PROVIDE ALL TEMPORARY PARTITIONS AND TEMPORARY DOORSAS INDICATED ON THIS DEMOLITION PLAN, OR AS DEEMED NECESSARY BY THE ARCHITECT ANDOWNER. THEY SHALL BE MAINTAINED AND REPAIRED IMMEDIATELY IF ANY DAMAGE OCCURS. THESEDOOR ARE TO AVOID MIGRATION OF DUST INTO THE ADJOINING AREAS.GENERAL CONTRACTOR TO VERIFY DUCTWORK OR PIPING PENETRATIONS THROUGH WALLS ABOVECEILING. IF PENETRATIONS OCCUR AND DUCTWORK OR PIPING IS TO BE REMOVED OR RELOCATED,FILL IN OPENINGS TO BE FLUSH WITH AND OF THE SAME MATERIAL AS THE SURROUNDING WALL.MAKE ALL DEMOLITION CLEAN AND COMPLETE IN A MANNER SUITABLE TO ACCEPT NEW SPECIFIEDFINISHES AND OR SURFACES. REFER TO ARCHITECTURAL PLANS, SPECIFICATIONS, AND DETAILS FORSPECIFIC INFORMATION REGARDING APPLICATION OF NEW MATERIAL.CBDEMOLITION NOTESADOOR SCHEDULEDOORFRAMEHARDWARENO.SIZEWIDEHGTTHICKTYPEFINISHRATINGTYPEREMARKSDOOR KEYNOTESDOORS NOT INDICATED BY DOOR NUMBER DESIGNATION ARE EXISTING.ALL NEW DOORS TO BE BUILDING STANDARD DOORS AND HARDWAREFINISHRATINGTYPEFINISHAB1RATE1RATE21-3/4"7'-0"3'-0"108ALL IDEAS, DESIGNS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY, AND THE PROPERTY OF MITSCH DESIGN. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. ALL RIGHTS RESERVED, EXCEPT FOR USES EXPRESSLY PERMITTED IN WRITING. FCC DEVELOPMENT MERIDIAN N MEDICAL BUILDING SUITE 100 BUILD-OUT 13590-B NORTH MERIDIAN ST CARMEL, IN 46032 STATE SUBMITTAL SETCRES17023PRELIMINARY SET PRICING SET STATE SUBMITTAL SET CONSTRUCTION SET 200 s rangeline roadsuite 213carmel, indiana 46032ph 317.573.2222fx 317.573.2230www.mitschdesign.comTAA TU SA R T R. H S EDD R EITCH C 1RATE1RATE21-3/4"7'-0"3'-0"101NOTE BNOTE BNOTE BNOTE BNOTE BNOTE B2RATE1RATE11-3/4"7'-0"3'-0"102NOTE BNOTE BNOTE B2RATE1RATE21-3/4"7'-0"3'-0"103NOTE BNOTE BNOTE B1RATE1RATE11-3/4"7'-0"3'-0"104NOTE BNOTE BNOTE B2RATE1RATE21-3/4"7'-0"3'-0"105ANOTE BNOTE BNOTE B2RATE1RATE11-3/4"7'-0"3'-0"105BNOTE BNOTE BNOTE B1RATE1RATE11-3/4"7'-0"3'-0"106NOTE BNOTE BNOTE B2RATE1RATE11-3/4"7'-0"3'-0"107NOTE BNOTE BNOTE B 3333 33IA201RCP / ELECTRICALPLAN (LOCATION ONLY)AS NOTEDPAINT NEW GYPSUM BOARD BULKHEADS OR HEADERS CEILING WHITE, UNLESS NOTED OTHERWISE.THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING HEIGHTSAND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, AND OTHEROBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT INDICATED. ANY DISCREPANCY SHALL BEBROUGHT TO THE DESIGNER'S ATTENTION PRIOR TO PERFORMING ANY WORK.CEILING HEIGHT THROUGHOUT THE SPACE TO COORDINATE WITH EXISTING SPRINKLER LOCATIONS,UNLESS NOTED OTHERWISE.ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OFSWITCH 6"-9" FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE.EXIT SIGNS, DOWN LIGHTS, SPRINKLER HEADS, ETC. SHALL BE CENTERED WITHIN CEILING TILE,UNLESS NOTED OTHERWISE.COLOR OF LIGHT SWITCH DEVICES AND COVERPLATE TO BE BUILDING STANDARD, UNLESS NOTEDOTHERWISE.ALL MULTIPLE SWITCH LOCATIONS TO BE GROUPED TOGETHER AND LABELED WITH A SINGLE DEVICECOVERPLATE.CONTRACTOR'S ELECTRICAL SUBCONTRACTOR TO PROVIDE INFORMATION, LOCATION ANDSPECIFICATIONS ON EXIT SIGNAGE, LIFE SAFETY SYSTEMS, 24 HOUR EMERGENCY LIGHTING,VENTILATION, HVAC SYSTEMS, CIRCUITING OF LIGHTS AND THERMOSTAT LOCATION ETC.THERMOSTATS SHALL BE LOCATED DIRECTLY ABOVE OR ADJACENT TO LIGHT SWITCH. ALLTHERMOSTAT POSITIONS AND LOCATIONS TO BE COORDINATED WITH THE DESIGNER BEFOREPLACEMENT.SUPPLY AND RETURN AIR GRILLES ARE TO BE FLUSH WITH NEW CEILING TILES AND ARE TO BE WHITEIN COLOR. REFER TO ENGINEERING DOCUMENTS FOR ADDITIONAL INFORMATION.IF REQUIRED, ALL CEILING MOUNTED EQUIPMENT LOCATIONS TO BE COORDINATED WITH THEDESIGNER PRIOR TO INSTALLATION.VERIFY ALL SPRINKLER HEAD LOCATIONS. NOTIFY DESIGNER IF ANY DISCREPANCIES OCCUR.AGENERAL REFLECTED CEILING PLAN NOTESBCDEFGHIJKLDENOTES NEW 2' X 2' BUILDING STANDARD CEILING TILEREFLECTED CEILING LEGENDREFLECTED CEILING PLAN KEYNOTESNOT IN CONTRACTDENOTES NEW BUILDING STANDARD 2'X2' LIGHT FIXTUREHEADER LOCATED AT 8'-0" A.F.F.DENOTES NEW EMERGENCY EXIT SIGNDENOTES NEW EMERGENCY LIGHTDENOTES LIGHT SWITCHSDENOTES LIGHT 3-WAY SWITCHS3DENOTES NEW DIFFUSERDENOTES NEW RETURNDENOTES NEW SPRINKLERSALL IDEAS, DESIGNS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY, AND THE PROPERTY OF MITSCH DESIGN. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. ALL RIGHTS RESERVED, EXCEPT FOR USES EXPRESSLY PERMITTED IN WRITING. FCC DEVELOPMENT MERIDIAN N MEDICAL BUILDING SUITE 100 BUILD-OUT 13590-B NORTH MERIDIAN ST CARMEL, IN 46032 STATE SUBMITTAL SETCRES17023PRELIMINARY SET PRICING SET STATE SUBMITTAL SET CONSTRUCTION SET 200 s rangeline roadsuite 213carmel, indiana 46032ph 317.573.2222fx 317.573.2230www.mitschdesign.comTAA TUSAR T R. H S EDDR EITCH C THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE DESIGNER OF ANY DISCREPANCIES BETWEEN THECONTRACT DOCUMENTS AND APPLICABLE CODES PRIOR TO CONSTRUCTION.ELECTRICAL CONTRACTOR TO COORDINATE ALL SPECIAL ELECTRICAL EQUIPMENT REQUIREMENTSAS INDICATED ON DRAWINGS OR AS REQUESTED BY TENANT. VERIFY ACTUAL REQUIREMENTS WITHDESIGNER PRIOR TO INSTALLATION.ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES AND PULL STRINGS AT TELEPHONE/DATALOCATIONS AS INDICATED ON PLANS. COMPLETE TELEPHONE/DATA SYSTEMS (MATERIAL AND LABOR)TO BE PROVIDED BY THE TENANT UNLESS OTHERWISE NOTED.ALL SECURITY SYSTEMS TO BE PROVIDED BY TENANT UNLESS NOTED OTHERWISE.ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL AND LIGHTING REQUIREMENTS FORMILLWORK AND CABINETRY WITH CONTRACTOR AS NECESSARY.ALL WALL MOUNTED OUTLETS ARE TO BE MOUNTED VERTICALLY AT 16" A.F.F. TO CENTERLINE OFOUTLET, UNLESS OTHERWISE NOTED.SWITCH PLATES, MONUMENTS, AND ELECTRICAL COVER PLATES SHALL BE WHITE IN COLOR.ALL DIMENSIONS SHOWN ARE TO CENTERLINE OF OUTLETS OR GROUP OF OUTLETS, UNLESSOTHERWISE NOTED.DO NOT LOCATE BOXES BACK TO BACK WITHIN PARTITIONS. STAGGER AS REQUIRED TO MINIMIZESOUND TRANSMISSION.ADJACENT OUTLETS SHALL BE GANGED WHEN POSSIBLE. IF THEY CANNOT BE GANGED, THEY SHALLBE INSTALLED WITH A MINIMUM DISTANCE BETWEEN UNITS.CONTRACTOR TO PROVIDE ALL FIRE LIFE SAFETY DEVICES AS REQUIRED BY STATE AND LOCALBUILDING CODES.ELECTRICAL CONTRACTOR TO VERIFY WORKING CONDITION OF ALL SWITCHES, LIGHT FIXTURES,BALLASTS, EXIT, AND EMERGENCY LIGHTS AND OUTLETS, REPLACE IF NECESSARY.DO NOT SCALE DRAWINGS; ALL DIMENSIONS GIVEN ARE TO BE ADHERED TO, UNLESS FIELDCONDITIONS DEEM OTHERWISE. ANY CONFLICTS THAT MAY EXIST WITH NEW CONSTRUCTION MUSTBE REVIEWED BY DESIGNER PRIOR TO CONSTRUCTION OF WORK. DO NOT CIRCUMVENT DIMENSIONSBY ATTACHING RECEPTACLES TO NEAREST STUD.THESE ELECTRICAL DRAWINGS REFLECT LOCATIONS ONLY. CONSULT WITH ELECTRICAL ENGINEERFOR FURTHER TECHNICAL INFORMATION.ELECTRICAL/DATA OUTLET LOCATIONS TO BE VERIFIED WITH TENANT PRIOR TO ROUGH-IN. ALLLOCATIONS TO BE VERIFIED WITH FURNITURE PLACEMENT.ABCDEFGHIJKLMNOGENERAL ELECTRICAL/DATA NOTESELECTRICAL/DATA LEGENDDENOTES CENTERLINE MOUNTING HEIGHT OF OUTLET/RECEPTACLEDENOTES ITEM FOR TENANT PROVIDED TVDENOTES GROUND FAULT INTERRUPTER+##TVGFIDEDICATED QUAD RECEPTACLEDEDICATED DUPLEX RECEPTACLE110V STANDARD QUAD RECEPTACLE110V STANDARD DUPLEX RECEPTACLEVOICE/DATA OUTLETNOT IN CONTRACT FURNACE160 CFM160 CFM160 CFM160 CFM160 CFM160 CFM160 CFM100 CFM120 CFMCARRIER - FB4CNF042CARRIER - 34ABB342LAVLAVTO EXISTBUILDING DRAINTO EXISTBUILDING DRAIN2"2"5 gal WATERHEATER1/2" COLDFROM EXIST1/2" H1/2" CPLUMBING ISONOT TO SCALELEVEL TWOLAV2"4" EXISTING DRAIN2" VENT TO THE EXISTINGIA251MECHANICALPLUMBING PLANAS NOTEDALL IDEAS, DESIGNS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY, AND THE PROPERTY OF MITSCH DESIGN. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. ALL RIGHTS RESERVED, EXCEPT FOR USES EXPRESSLY PERMITTED IN WRITING. FCC DEVELOPMENT MERIDIAN N MEDICAL BUILDING SUITE 100 BUILD-OUT 13590-B NORTH MERIDIAN ST CARMEL, IN 46032 STATE SUBMITTAL SETCRES17023PRELIMINARY SET PRICING SET STATE SUBMITTAL SET CONSTRUCTION SET 200 s rangeline roadsuite 213carmel, indiana 46032ph 317.573.2222fx 317.573.2230www.mitschdesign.comTAA TUSAR T R. H S EDD R EITCH C THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE DESIGNER OF ANY DISCREPANCIES BETWEEN THECONTRACT DOCUMENTS AND APPLICABLE CODES PRIOR TO CONSTRUCTION.ELECTRICAL CONTRACTOR TO COORDINATE ALL SPECIAL ELECTRICAL EQUIPMENT REQUIREMENTSAS INDICATED ON DRAWINGS OR AS REQUESTED BY TENANT. VERIFY ACTUAL REQUIREMENTS WITHDESIGNER PRIOR TO INSTALLATION.ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES AND PULL STRINGS AT TELEPHONE/DATALOCATIONS AS INDICATED ON PLANS. COMPLETE TELEPHONE/DATA SYSTEMS (MATERIAL AND LABOR)TO BE PROVIDED BY THE TENANT UNLESS OTHERWISE NOTED.ALL SECURITY SYSTEMS TO BE PROVIDED BY TENANT UNLESS NOTED OTHERWISE.ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL AND LIGHTING REQUIREMENTS FORMILLWORK AND CABINETRY WITH CONTRACTOR AS NECESSARY.ALL WALL MOUNTED OUTLETS ARE TO BE MOUNTED VERTICALLY AT 16" A.F.F. TO CENTERLINE OFOUTLET, UNLESS OTHERWISE NOTED.SWITCH PLATES, MONUMENTS, AND ELECTRICAL COVER PLATES SHALL BE WHITE IN COLOR.ALL DIMENSIONS SHOWN ARE TO CENTERLINE OF OUTLETS OR GROUP OF OUTLETS, UNLESSOTHERWISE NOTED.DO NOT LOCATE BOXES BACK TO BACK WITHIN PARTITIONS. STAGGER AS REQUIRED TO MINIMIZESOUND TRANSMISSION.ADJACENT OUTLETS SHALL BE GANGED WHEN POSSIBLE. IF THEY CANNOT BE GANGED, THEY SHALLBE INSTALLED WITH A MINIMUM DISTANCE BETWEEN UNITS.CONTRACTOR TO PROVIDE ALL FIRE LIFE SAFETY DEVICES AS REQUIRED BY STATE AND LOCALBUILDING CODES.ELECTRICAL CONTRACTOR TO VERIFY WORKING CONDITION OF ALL SWITCHES, LIGHT FIXTURES,BALLASTS, EXIT, AND EMERGENCY LIGHTS AND OUTLETS, REPLACE IF NECESSARY.DO NOT SCALE DRAWINGS; ALL DIMENSIONS GIVEN ARE TO BE ADHERED TO, UNLESS FIELDCONDITIONS DEEM OTHERWISE. ANY CONFLICTS THAT MAY EXIST WITH NEW CONSTRUCTION MUSTBE REVIEWED BY DESIGNER PRIOR TO CONSTRUCTION OF WORK. DO NOT CIRCUMVENT DIMENSIONSBY ATTACHING RECEPTACLES TO NEAREST STUD.THESE ELECTRICAL DRAWINGS REFLECT LOCATIONS ONLY. CONSULT WITH ELECTRICAL ENGINEERFOR FURTHER TECHNICAL INFORMATION.ELECTRICAL/DATA OUTLET LOCATIONS TO BE VERIFIED WITH TENANT PRIOR TO ROUGH-IN. ALLLOCATIONS TO BE VERIFIED WITH FURNITURE PLACEMENT.ABCDEFGHIJKLMNOGENERAL ELECTRICAL/DATA NOTESELECTRICAL/DATA LEGENDDENOTES CENTERLINE MOUNTING HEIGHT OF OUTLET/RECEPTACLEDENOTES ITEM FOR TENANT PROVIDED TVDENOTES GROUND FAULT INTERRUPTER+##TVGFIDEDICATED QUAD RECEPTACLEDEDICATED DUPLEX RECEPTACLE110V STANDARD QUAD RECEPTACLE110V STANDARD DUPLEX RECEPTACLEVOICE/DATA OUTLETNOT IN CONTRACT