HomeMy WebLinkAbout17030177 Truss PlansBM2
RB1
VB1
U1
T2
T1ABB1AA1Z1ADB1
DUG1
DTB1
DV1
DUG1
DV1
DW1
DYG1
DYG1
V4
V5
V10
V15
V20 V7V12V17V8
V14
V19
PB1PB1APB1BPB3PB7 Q1(4)AU1(9)
O1(3)O1(3) P1(4)
PB1(6)
AP1(3)AC1(5)DX1(4)DX1(3)BM1ALB1AMG1DG1
BB1
A1
C1
AOG1
ANB1SG1AQ2
YG1
XB1
W1
W2
K1J1H1E1I1F2G1AH1AG1AE1AE1AE2AF1AJ1NB1AK1
AK1GAS1AS1V1
V2
V3
V6
V11
V16
V9
V13
V18
V21V22PB6
PB4
PB5AR1(3)AQ1(4)F1(4)
AI1(3)
M1(2) L1(7)
PB4(6)
AT1(4)PB4(2)PB2(8)
Order #: 17010206
Drake Residence
Carter Lumber
2901 N. Morton St.
Franklin, Indiana 46131
(317) 346-1300
THIS IS A TRUSS PLACEMENT DIAGRAM ONLY.These trusses are designed as individual building components to be incorporated
into the building design at the specification of the building designer. See individual design sheets for each truss design identified on
the placement drawing. The building designer is responsible for temporary and permanent bracing of the roof and floor system and
for the overall structure. The design of the truss support structure including headers, beams, walls, and columns is the responsibility of
the building designer. For general guidance regarding bracing, consult "Bracing of Wood Trusses" available from the Truss Plate
Institute, 583 D'Onifrio Drive; Madison, WI 53179.
SHOP DRAWING APPROVAL
THIS LAYOUT IS THE SOLE SOURCE FOR FABRICATION OF TRUSSES AND VOIDS ALL PREVIOUS ARCHITECTURAL OR
OTHER TRUSS LAYOUTS. REVIEW AND APPROVAL OF THIS LAYOUT MUST BE RECEIVED BEFORE ANY TRUSSES WILL
BE BUILT. VERIFY ALL CONDITIONS TO INSURE AGAINST CHANGES THAT WILL RESULT IN EXTRA CHARGES TO YOU.
REVIEWED BY:__________________________ APPROVED BY:______________________________ DATE:___________
William Custom Art Builders
Scale: NTS Drawn By: A. GarrettDate: 4/12/17
Model/Elevation
Custom
NOTES:
1.) Valley trusses are designed to sit on sheathing.
2.) Installation of all temporary and permanent braces is essential.
See truss drawings, BCSI-1 Building Component Safety Information
and building designers requirements.
3.) Provide solid bearing for beams and girders. See Code and/or
building designer requirements.
4.) Trusses are NOT designed to be field modified unless noted
otherwise. If any alterations are to be considered ALWAYS consult
a qualified truss designer or engineer BEFORE making any alterations.
5.) Add/remove overhangs as needed.
HANGERS:
Install all hangers per manufacturer's requirements.
MULTI-PLY GIRDER TRUSS:
See drawing of multiple ply girders for fastening pattern to connect plys
so they act as one. All plys must be fastened together before supported
trusses or framing is attached to girders.