HomeMy WebLinkAbout17030177 Truss Plans (2)Re:
The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision
based on the parameters provided by Carter Components-Pittsboro, IN.
Liu, Xuegang
Pages or sheets covered by this seal: I29546984 thru I29547073
My license renewal date for the state of Indiana is July 31, 2018.
A
Truss Engineer’s responsibility is solely for
design of individual trusses based upon design parameters shown
on referenced truss drawings. Parameters have not been verified
as appropriate for any use. Any location identification specified is
for file reference only and has not been used in preparing design.
Suitability of truss designs for any particular building is the
responsibility of the building designer, not the Truss Engineer,
per ANSI/TPI-1, Chapter 2.
IMPORTANT NOTE:
17010206 Drake Residence
16023 Swingley Ridge Rd
Chesterfield, MO 63017
314-434-1200
MiTek USA, Inc.
April 12,2017
Job
A
Truss
A1
Truss Type
Piggyback Base
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546984
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:47 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-XUZpw_LRFKoWKibWly9UeRdtyRw7b3SPROdZCWzRSaw
Scale = 1:67.2
12
3
4
5 6
7
8
9
10
13 12 11
20
21
22 23
24
25
3x6
5x6 6x8
3x6
6x8
3x6
2x4
5x8 3x4
2x4
6x8
11-0-0
11-0-0
18-4-0
7-4-0
29-4-0
11-0-0
-0-11-0
0-11-0
5-6-7
5-6-7
11-0-0
5-5-9
18-4-0
7-4-0
23-9-9
5-5-9
29-4-0
5-6-7
30-3-0
0-11-0
0-7-1011-7-100-7-1011-7-1012.00 12
Plate Offsets (X,Y)-- [2:0-4-1,Edge], [2:0-0-7,0-3-4], [2:0-0-4,0-0-9], [5:0-4-4,0-1-12], [6:0-6-4,0-1-12], [9:0-0-4,0-0-9], [9:0-0-7,0-3-4], [9:0-4-1,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.53
0.77
0.29
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.33
-0.82
0.04
(loc)
11-19
11-19
2
l/defl
>999
>430
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 142 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
WEDGE
Left: 2x8 SP No.1, Right: 2x8 SP No.1
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-7-10 oc purlins,
except
2-0-0 oc purlins (5-7-14 max.): 5-6.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 6-13
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)2=1228/0-3-8, 9=1228/0-3-8
Max Horz 2=331(LC 6)
Max Uplift 2=-145(LC 7), 9=-145(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1376/249, 3-5=-1161/297, 5-6=-735/283, 6-8=-1161/297, 8-9=-1376/249
BOT CHORD 2-13=-250/911, 11-13=-53/734, 9-11=-44/911
WEBS 3-13=-257/230, 5-13=-49/449, 6-11=-63/449, 8-11=-257/230
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 11-0-0, Exterior(2) 11-0-0 to 22-6-15, Interior(1) 22-6-15 to 30-3-0 zone;
cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=145, 9=145.
6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AA1
Truss Type
Half Hip
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546985
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:48 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-?g6C7JM40ewMysAiJfgjBeA47rIIKXcZf2M7lyzRSav
Scale = 1:59.6
1
2
3 4 5
8 7 6
9
10 11 12 13
4x5 3x6
2x4 5x6
3x4
3x10
4x5
4-8-0
4-8-0
14-3-8
9-7-8
-0-11-0
0-11-0
4-8-0
4-8-0
9-4-0
4-8-0
14-3-8
4-11-8
5-11-410-7-412.00 12
Plate Offsets (X,Y)-- [2:0-1-12,0-1-8], [3:0-3-4,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.44
0.65
0.23
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.22
-0.55
-0.01
(loc)
6-7
6-7
6
l/defl
>763
>304
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 99 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
2-8: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5.
BOT CHORD Rigid ceiling directly applied or 7-8-11 oc bracing.
WEBS 1 Row at midpt 5-6, 3-7, 4-7, 4-6
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)8=626/0-3-8, 6=558/0-3-8
Max Horz 8=404(LC 6)
Max Uplift 8=-89(LC 5), 6=-245(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-362/163, 2-8=-610/204
BOT CHORD 7-8=-533/309, 6-7=-261/173
WEBS 4-6=-392/369, 2-7=-134/309
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 4-8-0, Exterior(2) 4-8-0 to 8-10-15 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8 except (jt=lb)
6=245.
6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
ABB1
Truss Type
GABLE
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546986
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:48 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-?g6C7JM40ewMysAiJfgjBeA_KrSWKTxZf2M7lyzRSav
Scale = 1:52.0
1
2 3
4
5 6 7 8 9 10 11 12 13 14
26 25 24 23 22 21 20 19 18 17 16 15
27 28 29
4x10 MT18H
5x10
6x8 3x6 3x6 3x6 3x6 3x6 3x6 3x6 3x6 3x6
14-3-8
14-3-8
-0-11-0
0-11-0
2-8-0
2-8-0
14-3-8
11-7-8
5-11-48-7-412.00 12
Plate Offsets (X,Y)-- [2:0-5-0,0-1-12], [24:0-6-0,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-R
0.81
0.06
0.47
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
1
2
15
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
MT18H
Weight: 226 lb FT = 20%
GRIP
174/144
174/144
LUMBER-
TOP CHORD 1-1/2" x 11-7/8" VERSA-LAMfi 1.7 2400 DF *Except*
5-14: 2x10 SP 2400F 2.0E
BOT CHORD 1-1/2" x 11-7/8" VERSA-LAMfi 1.7 2400 DF
WEBS 2x4 SPF 2100F 1.8E *Except*
14-15: 2x4 SPF No.2
OTHERS 2x4 SPF No.2 *Except*
3-25: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 5-14.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except:
10-0-0 oc bracing: 25-26,24-25.
WEBS 1 Row at midpt 14-15
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 14-3-8.
(lb) - Max Horz 26=303(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 17, 18, 19, 20, 21, 22 except
26=-655(LC 5), 15=-214(LC 6), 16=-231(LC 5), 23=-222(LC 5), 24=-386(LC 6),
25=-737(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 15, 16, 17, 18, 19, 20, 21, 22
except 26=894(LC 6), 23=296(LC 6), 24=290(LC 5), 25=550(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-26=-431/220, 2-3=-407/212, 3-4=-309/192, 4-5=-76/341
WEBS 6-23=-528/257, 4-24=-346/821
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Corner(3) -0-11-0 to 2-1-1, Exterior(2) 2-1-1 to 2-8-0, Corner(3) 2-8-0 to 5-8-0 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Provide adequate drainage to prevent water ponding.
5) All plates are MT20 plates unless otherwise indicated.
6) All plates are 3x10 MT20 unless otherwise indicated.
7) Gable requires continuous bottom chord bearing.
8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
9) Gable studs spaced at 1-4-0 oc.
10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 18, 19, 20,
21, 22 except (jt=lb) 26=655, 15=214, 16=231, 23=222, 24=386, 25=737.
12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AC1
Truss Type
Scissor
Qty
5
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546987
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:49 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-TsgaLfNiny2Da0kusNByjsiHxFha3zxiui6gHOzRSau
Scale = 1:46.5
1
2
3
4
5
6 7
817
18
19 20
21
22
5x8
3x4
5x8
5x8
3x4
4x5
6-8-0
6-8-0
13-4-0
6-8-0
-0-11-0
0-11-0
6-8-0
6-8-0
13-4-0
6-8-0
14-3-0
0-11-0
0-7-107-3-100-7-103-2-412.00 12
6.00 12
Plate Offsets (X,Y)-- [2:0-1-8,0-2-0], [6:0-1-4,0-2-7], [8:0-3-15,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.31
0.45
0.29
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.13
-0.17
0.09
(loc)
8-15
8-15
6
l/defl
>999
>938
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 51 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
SLIDER Left 2x4 SPF Stud 2-0-0, Right 2x4 SPF Stud 2-0-0
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)2=588/0-3-8, 6=588/0-3-8
Max Horz 2=201(LC 6)
Max Uplift 2=-100(LC 7), 6=-100(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-842/41, 4-6=-842/78
BOT CHORD 2-8=-48/618, 6-8=-26/618
WEBS 4-8=0/683
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 6-8-0, Exterior(2) 6-8-0 to 9-8-0 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Bearing at joint(s) 2, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
ADB1
Truss Type
GABLE COMMON
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546988
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:50 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-x3EyY?OKYFA4BAJ4Q4jBG3FVDf76oTbr7MrDprzRSat
Scale = 1:43.7
1
2
3
4
5
6
7
8
9
10
11
12
13
20
19
18
17
16
15
14
21
22
23 24
25
26
4x5
3x4
3x4
5x6
3x4
3x4
6-8-0
6-8-0
13-4-0
6-8-0
-0-11-0
0-11-0
6-8-0
6-8-0
13-4-0
6-8-0
14-3-0
0-11-0
0-7-107-3-100-7-103-2-412.00 12
6.00 12
Plate Offsets (X,Y)-- [2:0-1-3,0-0-7], [12:0-1-3,0-0-7]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-S
0.08
0.05
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
0.00
0.00
(loc)
12
12
12
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 66 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud
SLIDER Left 2x4 SPF Stud 1-9-12, Right 2x4 SPF Stud 1-9-12
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 13-4-0.
(lb) - Max Horz 2=210(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 12, 18, 19, 16, 15 except 2=-152(LC 5), 20=-149(LC 7),
14=-142(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 2, 12, 18, 19, 20, 16, 15, 14 except 17=398(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 7-17=-252/0
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 6-8-0, Exterior(2) 6-8-0 to 9-8-0 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 2x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 18, 19, 16, 15
except (jt=lb) 2=152, 20=149, 14=142.
9) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 17, 18, 19, 20, 16, 15, 14.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AE1
Truss Type
Piggyback Base
Qty
2
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546989
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:50 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-x3EyY?OKYFA4BAJ4Q4jBG3FRxf3qoRXr7MrDprzRSat
Scale = 1:31.2
1
2
3
4
5 6 7
14 13
12 11 10
9 8
18 19 20 21
5x8
3x4 3x6 2x4
3x6
5x10
2x4
2x4
3x6
3x4
5x12
3x4
3x4
1-2-3
1-2-3
2-3-8
1-1-5
4-4-8
2-1-0
9-1-0
4-8-8
11-4-0
2-3-0
-0-11-0
0-11-0
1-2-3
1-2-3
2-3-8
1-1-5
4-4-8
2-1-0
9-1-0
4-8-8
11-4-0
2-3-0
0-7-105-0-21-0-012.00 12
Plate Offsets (X,Y)-- [2:0-0-13,0-3-3], [2:0-0-7,0-0-7], [5:0-6-4,0-1-12], [10:0-2-12,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MP
0.35
0.26
0.21
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.02
-0.06
0.03
(loc)
10-11
10-11
8
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 66 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
4-13,6-9: 2x4 SPF Stud
WEBS 2x4 SPF Stud
WEDGE
Left: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-7.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
8-8-3 oc bracing: 11-12.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)8=445/0-3-0, 2=505/0-3-8
Max Horz 2=190(LC 6)
Max Uplift 8=-109(LC 6), 2=-94(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-462/93, 3-4=-778/305, 4-5=-512/131, 7-8=-421/196
BOT CHORD 2-14=-256/279, 11-12=-461/578, 10-11=-226/329, 6-10=-295/169
WEBS 3-14=-324/259, 12-14=-364/389, 3-12=-204/301, 4-11=-300/275, 5-11=-65/282,
7-10=-213/482
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-12, Interior(1) 2-1-12 to 4-4-8, Exterior(2) 4-4-8 to 8-7-7 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2 except (jt=lb)
8=109.
6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AE2
Truss Type
Piggyback Base
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546990
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:51 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-PFoKlLPyJZIxpJuH_oEQpHoVD3NlXs5?L0bnLHzRSas
Scale = 1:31.2
1
2
3 4
6 5
10
11 12 13 14
5x8 2x4
3x10 2x4 3x4
4-4-8
4-4-8
11-4-0
6-11-8
-0-11-0
0-11-0
4-4-8
4-4-8
11-4-0
6-11-8
0-7-105-0-212.00 12
Plate Offsets (X,Y)-- [2:0-3-8,Edge], [2:0-0-13,0-3-3], [2:0-0-7,0-0-7], [3:0-6-4,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MP
0.83
0.41
0.38
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.07
-0.17
-0.01
(loc)
5-6
5-6
2
l/defl
>999
>786
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 49 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud *Except*
3-5: 2x4 SPF No.2
WEDGE
Left: 2x6 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (9-0-12 max.): 3-4.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)2=505/0-3-8, 5=445/0-3-0
Max Horz 2=190(LC 6)
Max Uplift 2=-94(LC 7), 5=-109(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-480/110
BOT CHORD 2-6=-180/266, 5-6=-178/271
WEBS 3-6=0/282, 3-5=-330/153
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 4-4-8, Exterior(2) 4-4-8 to 8-7-7 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2 except (jt=lb)
5=109.
6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AF1
Truss Type
Monopitch
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546991
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:51 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-PFoKlLPyJZIxpJuH_oEQpHoY83OlXrR?L0bnLHzRSas
Scale = 1:65.6
1
2
3
4
6 5
10
11
123x6
2x4
3x6
3x6
2x4 3x6
5-6-11
5-6-11
11-4-0
5-9-5
5-6-11
5-6-11
11-4-0
5-9-5
0-7-1011-11-1012.00 12
Plate Offsets (X,Y)-- [1:0-0-7,0-0-7], [1:0-0-13,0-3-3]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MP
0.58
0.34
0.42
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.05
-0.07
-0.01
(loc)
6-9
5-6
1
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 67 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
4-5: 2x6 SPF No.2, 2-6: 2x4 SPF Stud
WEDGE
Left: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 4-5
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=444/0-3-8, 5=444/0-3-0
Max Horz 1=430(LC 6)
Max Uplift 1=-10(LC 5), 5=-214(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-457/125, 2-4=-325/219, 4-5=-178/266
BOT CHORD 1-6=-290/260, 5-6=-290/260
WEBS 2-6=0/264, 2-5=-378/237
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 11-1-4 zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb)
5=214.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AG1
Truss Type
Piggyback Base
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546992
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:52 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-tRMizhPa4tQoRTTTYVlfLUKgzSjxGJG8agKKujzRSar
Scale = 1:30.9
1
2 3
5
4
9
10 11 12 13
5x8 2x4
2x4 3x4 3x10
4-4-8
4-4-8
11-4-0
6-11-8
4-4-8
4-4-8
11-4-0
6-11-8
0-7-105-0-212.00 12
Plate Offsets (X,Y)-- [1:0-3-8,Edge], [1:0-0-13,0-3-3], [1:0-0-7,0-0-7], [2:0-6-4,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MP
0.83
0.41
0.38
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.07
-0.17
-0.01
(loc)
4-5
4-5
1
l/defl
>999
>791
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 48 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud *Except*
2-4: 2x4 SPF No.2
WEDGE
Left: 2x6 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (9-0-12 max.): 2-3.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)4=447/0-3-0, 1=447/0-3-8
Max Horz 1=175(LC 6)
Max Uplift 4=-109(LC 6), 1=-52(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-484/117
BOT CHORD 1-5=-181/270, 4-5=-180/275
WEBS 2-5=0/283, 2-4=-335/155
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 4-4-8, Exterior(2) 4-4-8 to 8-7-7 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb)
4=109.
6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AH1
Truss Type
Piggyback Base
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546993
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:52 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-tRMizhPa4tQoRTTTYVlfLUKf?Sj3GMJ8agKKujzRSar
Scale = 1:30.9
1
2
3 4
8
7 6
5
9 10 11 12
2x4
3x4
4x5
4x5
2x4 3x4 3x10
3x4
1-2-8
1-2-8
4-4-8
3-2-0
11-4-0
6-11-8
1-2-8
1-2-8
4-4-8
3-2-0
11-4-0
6-11-8
1-10-25-0-212.00 12
Plate Offsets (X,Y)-- [3:0-3-4,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MP
0.89
0.40
0.19
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.07
-0.17
-0.00
(loc)
5-6
5-6
5
l/defl
>999
>779
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 55 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud *Except*
4-6: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (3-11-15 max.): 1-2, 3-4.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)8=442/Mechanical, 5=442/0-3-0
Max Horz 8=178(LC 6)
Max Uplift 8=-52(LC 7), 5=-109(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-8=-410/108, 2-3=-421/95, 3-4=-259/110, 4-5=-387/193
BOT CHORD 7-8=-258/140, 6-7=-266/260
WEBS 1-7=-103/439, 2-7=-388/96, 4-6=-144/317
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-1-12 to 1-2-8, Interior(1) 1-2-8 to 4-4-8, Exterior(2) 4-4-8 to 7-4-8 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8 except (jt=lb)
5=109.
7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AI1
Truss Type
Piggyback Base
Qty
3
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546994
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:53 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-Mew4A1QCrAYf2d2f5DGuuity8s6r?oNIpK4uQAzRSaq
Scale = 1:30.9
1
2
3 4 5
12
11
10 9 8
7
6
13
14 15 16 17
3x6
5x8
3x4 2x4
3x6
5x10
2x4
2x4
3x4
3x4
3x4
5x8
2-0-8
2-0-8
4-1-8
2-1-0
8-10-0
4-8-8
11-1-0
2-3-0
2-0-8
2-0-8
4-1-8
2-1-0
8-10-0
4-8-8
11-1-0
2-3-0
0-10-105-0-21-0-012.00 12
Plate Offsets (X,Y)-- [3:0-6-4,0-1-12], [8:0-2-12,0-2-0], [10:0-5-8,0-2-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MP
0.36
0.24
0.20
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.02
-0.06
0.02
(loc)
8-9
8-9
6
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 64 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
2-11,4-7: 2x4 SPF Stud
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
8-11-0 oc bracing: 9-10.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)6=432/0-3-0, 12=432/Mechanical
Max Horz 12=180(LC 6)
Max Uplift 6=-109(LC 6), 12=-49(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-649/273, 2-3=-479/137, 5-6=-407/198, 1-12=-404/177
BOT CHORD 9-10=-436/455, 8-9=-228/304, 4-8=-295/169
WEBS 3-9=-68/251, 5-8=-215/467, 10-12=-303/148, 1-10=-151/450
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 4-1-8, Exterior(2) 4-1-8 to 8-4-7 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12 except (jt=lb)
6=109.
7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AJ1
Truss Type
Common
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546995
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:53 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-Mew4A1QCrAYf2d2f5DGuuitxPs40?m1IpK4uQAzRSaq
Scale = 1:69.8
1
2
3 4
7 6
5
12
13
14
15
5x10
5x6 2x4
7x10
3x6
3x10
5-5-8
5-5-8
10-7-8
5-2-0
11-0-8
0-5-0
5-5-8
5-5-8
10-7-8
5-2-0
11-0-8
0-5-0
0-11-211-6-1011-1-1012.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MP
0.40
0.36
0.35
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.05
-0.06
-0.02
(loc)
6-10
5-6
1
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 72 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
2-6: 2x4 SPF Stud, 3-5: 2x6 SPF No.2
SLIDER Left 2x8 SP No.1 2-0-0
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 9-6-11 oc bracing.
WEBS 1 Row at midpt 3-5
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=425/0-3-8, 5=450/0-3-0
Max Horz 5=484(LC 6)
Max Uplift 1=-37(LC 5), 5=-273(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-411/159, 2-3=-267/217
BOT CHORD 1-6=-341/317, 5-6=-92/317
WEBS 2-5=-323/227
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 10-7-8, Exterior(2) 10-7-8 to 11-0-8 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb)
5=273.
FULL BEARING UNDER
THE LENGTH OF THE
EXTENSION IS REQ’D.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AK1
Truss Type
Hip
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546996
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:54 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-qqUTONRrcUgWgndsfwn7QvQ5OGT8kHMR2_pRyczRSap
Scale = 1:38.0
1
2
3 4
5
6
10 9 8 7
11
12 13
14
4x5 4x5
8x10
8x10 4x5 4x5
4-6-0
4-6-0
5-6-0
1-0-0
10-0-0
4-6-0
-0-11-0
0-11-0
4-6-0
4-6-0
5-6-0
1-0-0
10-0-0
4-6-0
10-11-0
0-11-0
0-9-136-0-130-9-136-0-1314.00 12
Plate Offsets (X,Y)-- [3:0-3-8,0-1-12], [4:0-3-8,0-1-12], [7:Edge,0-6-11], [7:0-1-12,0-0-0], [10:0-1-12,0-0-0], [10:Edge,0-6-11]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.39
0.17
0.09
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.01
-0.03
0.00
(loc)
9-10
7-8
7
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 55 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)10=452/0-5-8, 7=452/0-5-8
Max Horz 10=193(LC 6)
Max Uplift 10=-96(LC 7), 7=-96(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-370/130, 4-5=-370/130, 2-10=-410/179, 5-7=-410/179
BOT CHORD 9-10=-276/286
WEBS 2-9=-126/287, 5-8=-138/288
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 4-6-0, Exterior(2) 4-6-0 to 5-6-0, Interior(1) 9-10-4 to 10-11-0 zone; cantilever left
and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 7.
6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AK1G
Truss Type
Hip Girder
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546997
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:54 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-qqUTONRrcUgWgndsfwn7QvQ3IGTakH7R2_pRyczRSap
Scale = 1:24.3
1
2
3 4
5
6
8 7
15 16
17 18
5x8
4x5
3x6 3x6
2x4 3x4
2-6-0
2-6-0
7-6-0
5-0-0
10-0-0
2-6-0
-0-11-0
0-11-0
2-6-0
2-6-0
7-6-0
5-0-0
10-0-0
2-6-0
10-11-0
0-11-0
0-9-133-8-130-9-133-8-1314.00 12
Plate Offsets (X,Y)-- [2:0-1-1,0-4-1], [2:0-0-9,0-0-7], [3:0-6-8,0-1-12], [4:0-3-8,0-1-12], [5:0-0-9,0-0-7], [5:0-1-1,0-4-1]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MP
0.52
0.14
0.10
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.02
-0.02
0.00
(loc)
7-8
7-8
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 51 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF Stud
WEDGE
Left: 2x6 SPF No.2, Right: 2x6 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
2-0-0 oc purlins (6-0-0 max.): 3-4.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)2=619/0-5-8, 5=631/0-5-8
Max Horz 2=-99(LC 3)
Max Uplift 2=-361(LC 5), 5=-383(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-606/403, 3-4=-369/320, 4-5=-622/432
BOT CHORD 2-8=-267/348, 7-8=-276/358, 5-7=-242/359
WEBS 3-8=-218/293, 4-7=-257/314
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=361, 5=383.
6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 163 lb down and 174 lb up at
2-6-0, 90 lb down and 97 lb up at 4-6-12, and 90 lb down and 97 lb up at 6-6-12, and 163 lb down and 174 lb up at 7-5-4 on bottom
chord. The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-60, 3-4=-60, 4-6=-60, 9-12=-20
Concentrated Loads (lb)
Vert: 8=-117(F) 7=-117(F) 17=-53(F) 18=-53(F)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
ALB1
Truss Type
GABLE
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546998
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:55 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-I01rbjSTNooNIxC2DdIMz7yMDgrgTlLbGeZ_U2zRSao
Scale = 1:31.6
1
2
3
4
5
6
7
8
9
14 13 12 11 10
15 16
4x5
3x4 3x4
8-4-0
8-4-0
-0-11-0
0-11-0
4-2-0
4-2-0
8-4-0
4-2-0
9-2-8
0-10-8
0-7-104-9-100-7-1012.00 12
Plate Offsets (X,Y)-- [2:0-0-7,0-0-7], [2:0-0-13,0-3-3], [8:0-0-7,0-0-7], [8:0-0-13,0-3-3]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.06
0.02
0.04
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
0.00
(loc)
9
9
8
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 42 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud
WEDGE
Left: 2x4 SPF Stud, Right: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 8-4-0.
(lb) - Max Horz 2=135(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 2, 8, 13, 14, 11, 10
Max Grav All reactions 250 lb or less at joint(s) 2, 8, 12, 13, 14, 11, 10
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Corner(3) -0-11-0 to 2-1-0, Exterior(2) 2-1-0 to 4-2-0, Corner(3) 4-2-0 to 7-2-0 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 2x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8, 13, 14, 11,
10.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AMG1
Truss Type
Common Girder
Qty
1
Ply
2
17010206 Drake Residence
Job Reference (optional)
I29546999
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:56 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-mDbDp2S585xEv5nEnLpbWKVTM40ICz7kVIIY1VzRSan
Scale = 1:32.7
1
2
3
4
11 12
13 14 15
5x10 5x10 5x10
5x6
4-2-0
4-2-0
8-4-0
4-2-0
4-2-0
4-2-0
8-4-0
4-2-0
0-7-104-9-100-7-1012.00 12
Plate Offsets (X,Y)-- [1:0-0-0,0-0-1], [3:Edge,0-0-1], [4:0-6-4,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MP
0.29
0.77
0.97
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.03
-0.08
0.00
(loc)
4-10
4-10
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 102 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x10 SP 2400F 2.0E
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=2376/0-3-8, 3=6196/0-3-8
Max Horz 1=-123(LC 3)
Max Uplift 1=-522(LC 5), 3=-1388(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-3433/803, 2-3=-3383/794
BOT CHORD 1-4=-512/2362, 3-4=-512/2362
WEBS 2-4=-1034/4502
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x10 - 3 rows staggered at 0-2-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=522, 3=1388.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 121 lb down and 27 lb up at
0-5-12, 116 lb down and 30 lb up at 2-5-12, and 116 lb down and 30 lb up at 4-5-12, and 7551 lb down and 1713 lb up at 6-4-4 on
bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-60, 2-3=-60, 5-8=-20
Concentrated Loads (lb)
Vert: 7=-121(B) 13=-116(B) 14=-116(B) 15=-7551(B)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
ANB1
Truss Type
GABLE
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547000
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:56 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-mDbDp2S585xEv5nEnLpbWKVVP4BYCCkkVIIY1VzRSan
Scale = 1:22.6
1
2
3
4
5
6
7
12 11 10 9 8
3x10
4x5
3x10
2x4 2x4
2x4
2x4
2x4
5-0-0
5-0-0
-0-11-0
0-11-0
2-6-0
2-6-0
5-0-0
2-6-0
5-11-0
0-11-0
0-9-133-8-130-9-1314.00 12
Plate Offsets (X,Y)-- [2:0-2-1,0-1-12], [6:0-2-1,0-1-12], [6:0-5-0,0-0-12], [8:0-0-0,0-1-12], [12:0-0-0,0-1-12], [12:0-5-0,0-0-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-R
0.16
0.05
0.03
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.01
0.00
(loc)
7
7
8
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 26 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 5-0-0.
(lb) - Max Horz 12=119(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 12, 8, 11, 9
Max Grav All reactions 250 lb or less at joint(s) 12, 8, 10, 11, 9
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) automatic zone and C-C
Corner(3) -0-11-0 to 2-1-0, Exterior(2) 2-1-0 to 2-6-0, Corner(3) 2-6-0 to 5-6-0 zone; cantilever left and right exposed ; end vertical
left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable requires continuous bottom chord bearing.
5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 8, 11, 9.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AOG1
Truss Type
Common Girder
Qty
1
Ply
2
17010206 Drake Residence
Job Reference (optional)
I29547001
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:57 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-EP9b0OTjuP35XEMRK2Lq2Y2i4TV3xeYtky25ZxzRSam
Scale = 1:21.6
1
2
3
4
2x4
4x5
3x6 3x6
LUS26
LUS26 LUS26
2-6-0
2-6-0
5-0-0
2-6-0
2-6-0
2-6-0
5-0-0
2-6-0
0-9-133-8-130-9-1314.00 12
Plate Offsets (X,Y)-- [1:0-0-8,0-0-7], [1:0-1-1,0-4-1], [3:0-0-8,0-0-7], [3:0-1-1,0-4-1]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MP
0.04
0.09
0.12
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
0.00
(loc)
7
4
1
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 46 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF Stud
WEDGE
Left: 2x6 SPF No.2, Right: 2x6 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=822/0-3-8, 3=823/0-3-8
Max Horz 1=-90(LC 3)
Max Uplift 1=-127(LC 5), 3=-127(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-498/127, 2-3=-498/127
BOT CHORD 1-4=-51/299, 3-4=-51/299
WEBS 2-4=-136/580
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) automatic zone;
cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=127, 3=127.
7) Use Simpson Strong-Tie LUS26 (4-10d Girder, 3-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at
0-6-12 from the left end to 4-6-12 to connect truss(es) to back face of bottom chord.
8) Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-60, 2-3=-60, 5-8=-20
Concentrated Loads (lb)
Vert: 4=-412(B) 7=-416(B) 10=-417(B)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AP1
Truss Type
Monopitch
Qty
3
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547002
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:57 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-EP9b0OTjuP35XEMRK2Lq2Y2VHTUaxbotky25ZxzRSam
Scale = 1:55.6
1
2
3
5 4
6
7
2x4
2x4 5x6
3x6
4-5-8
4-5-8
-0-11-0
0-11-0
4-5-8
4-5-8
5-11-410-4-1212.00 12
Plate Offsets (X,Y)-- [4:0-3-0,0-3-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MP
0.86
0.19
0.30
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.02
-0.05
-0.00
(loc)
4-5
4-5
4
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 39 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud *Except*
3-4: 2x4 SPF 2100F 1.8E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-5-8 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 7-8-15 oc bracing.
WEBS 1 Row at midpt 3-4
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)5=239/0-3-8, 4=159/0-3-8
Max Horz 5=388(LC 6)
Max Uplift 5=-314(LC 5), 4=-462(LC 6)
Max Grav 5=464(LC 6), 4=424(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-319/196, 3-4=-162/274, 2-5=-748/339
BOT CHORD 4-5=-577/293
WEBS 2-4=-293/764
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) automatic zone and C-C
Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 4-3-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C
for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
5=314, 4=462.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AQ1
Truss Type
Monopitch
Qty
4
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547003
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:58 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-ibjzEkULfjBy9Owdums3blapxtpfg6k1ycne5NzRSal
Scale = 1:27.3
1
2
3
4
8
9
2x4
2x4 3x6
4-0-0
4-0-0
-0-11-0
0-11-0
4-0-0
4-0-0
0-7-104-7-1012.00 12
Plate Offsets (X,Y)-- [2:0-0-7,0-0-7], [2:0-0-13,0-3-3]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MP
0.29
0.20
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.02
-0.03
0.01
(loc)
4-7
4-7
2
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 18 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
WEDGE
Left: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)4=148/Mechanical, 2=216/0-3-8
Max Horz 2=168(LC 6)
Max Uplift 4=-80(LC 6), 2=-33(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) automatic zone and C-C
Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 3-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C
for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AQ2
Truss Type
Monopitch
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547004
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:58 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-ibjzEkULfjBy9Owdums3blarsto5g611ycne5NzRSal
Scale = 1:27.3
1
2
3
4
7
6 5
11
2x4
3x6 2x4
3x6
2x4
3x4
2-3-8
2-3-8
4-0-0
1-8-8
-0-11-0
0-11-0
2-3-8
2-3-8
4-0-0
1-8-8
0-7-104-7-103-7-101-0-012.00 12
Plate Offsets (X,Y)-- [2:0-0-7,0-0-7], [2:0-0-13,0-3-3]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MP
0.17
0.30
0.05
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
-0.01
-0.01
(loc)
7
7
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 21 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
3-7: 2x4 SPF Stud
WEBS 2x4 SPF Stud
WEDGE
Left: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)2=216/0-3-8, 5=148/Mechanical
Max Horz 2=152(LC 6)
Max Uplift 2=-30(LC 7), 5=-78(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) automatic zone and C-C
Exterior(2) -0-11-0 to 2-1-12, Interior(1) 2-1-12 to 3-10-4 zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AR1
Truss Type
Monopitch
Qty
3
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547005
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:58 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-ibjzEkULfjBy9Owdums3blarqto1g6p1ycne5NzRSal
Scale = 1:26.3
1
2
3
6
5 4
11
3x10
2x4
6x8
3x6
2x4
3x4
2-0-8
2-0-8
3-9-0
1-8-8
2-0-8
2-0-8
3-9-0
1-8-8
0-10-104-7-103-7-101-0-012.00 12
Plate Offsets (X,Y)-- [6:Edge,0-2-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MP
0.17
0.30
0.06
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
-0.00
-0.02
(loc)
10
6
4
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 24 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
2-6: 2x4 SPF Stud
WEBS 2x4 SPF Stud
SLIDER Left 2x8 SP No.1 1-9-0
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-9-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=136/Mechanical, 4=144/Mechanical
Max Horz 1=131(LC 6)
Max Uplift 1=-18(LC 5), 4=-85(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) automatic zone and C-C
Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 3-7-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AS1
Truss Type
Monopitch
Qty
2
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547006
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:59 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-AnHMR4VzQ0JpmYVpSTNI7z70YHB5PZ_ABFXCepzRSak
Scale = 1:21.9
1
2
3
4
5
12
2x4
2x4
3x10
5x6
3-4-15
3-4-15
-1-3-9
1-3-9
3-4-15
3-4-15
0-9-133-7-99.90 12
Plate Offsets (X,Y)-- [2:0-5-4,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MP
0.17
0.12
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
-0.01
-0.01
(loc)
5-10
5-10
2
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 21 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
SLIDER Left 2x8 SP No.1 2-0-0
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-4-15 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)5=92/Mechanical, 2=247/0-7-6
Max Horz 2=129(LC 6)
Max Uplift 5=-60(LC 6), 2=-71(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) automatic zone and C-C
Exterior(2) -1-3-9 to 1-8-7, Interior(1) 1-8-7 to 3-3-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C
for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AT1
Truss Type
Monopitch
Qty
4
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547007
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:47:59 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-AnHMR4VzQ0JpmYVpSTNI7z70WHCAPYpABFXCepzRSak
Scale = 1:22.9
1
2
3
5
4
2x4
4x5 8x10
2-6-0
2-6-0
-0-11-0
0-11-0
2-6-0
2-6-0
0-9-133-8-1314.00 12
Plate Offsets (X,Y)-- [5:0-1-12,0-0-0], [5:Edge,0-6-11]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MP
0.17
0.05
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
-0.00
(loc)
4-5
4-5
4
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 15 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-6-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)4=73/Mechanical, 5=167/0-5-8
Max Horz 5=142(LC 6)
Max Uplift 4=-85(LC 6), 5=-39(LC 5)
Max Grav 4=101(LC 5), 5=167(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
BOT CHORD 4-5=-277/79
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) automatic zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
AU1
Truss Type
Monopitch
Qty
9
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547008
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:00 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-e_rkeQWbBKRgOi4?0BuXgAg1qhYH8wLKQvGlAGzRSaj
Scale = 1:46.1
1
2
4 3
2x4
2x4 5x6
3x6
2-2-0
2-2-0
2-2-0
2-2-0
6-2-128-4-1212.00 12
Plate Offsets (X,Y)-- [3:0-3-0,0-3-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MP
0.78
0.06
0.44
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
-0.00
(loc)
4
3-4
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 29 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud *Except*
2-3: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 9-3-13 oc bracing.
WEBS 1 Row at midpt 2-3, 1-4
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)4=75/0-3-8, 3=75/0-3-8
Max Horz 4=-312(LC 5)
Max Uplift 4=-586(LC 5), 3=-621(LC 6)
Max Grav 4=624(LC 6), 3=637(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-4=-1090/646
BOT CHORD 3-4=-406/314
WEBS 1-3=-536/1023
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) automatic zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
4=586, 3=621.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
BB1
Truss Type
GABLE
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546986
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:01 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-7AP6smWEyeZW0sfCZuPmDOCNv5uitSGTfZ0JiizRSai
Scale = 1:67.2
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18
19
20
21
22
23
24
25
26
27
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28
49 50
3x6 3x6
3x6
5x6
5x6
3x6
5x6
29-4-0
29-4-0
-0-11-0
0-11-0
11-0-0
11-0-0
18-4-0
7-4-0
29-4-0
11-0-0
30-3-0
0-11-0
0-7-1011-7-100-7-1011-7-1012.00 12
Plate Offsets (X,Y)-- [2:0-0-7,0-0-7], [2:0-0-13,0-3-3], [4:0-3-0,0-3-0], [11:0-1-11,Edge], [17:0-1-11,Edge], [25:0-3-0,0-3-0], [26:0-0-13,0-3-3], [26:0-0-7,0-0-7], [37:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-S
0.11
0.05
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
0.01
(loc)
27
27
26
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 255 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2 *Except*
7-44,6-45,5-46,4-47,3-48,21-32,22-31,23-30,24-29,25-28: 2x4 SPF Stud
WEDGE
Left: 2x4 SPF Stud, Right: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
2-0-0 oc purlins (6-0-0 max.): 11-17.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 14-38, 13-39, 12-40, 10-41, 9-42, 8-43,
15-37, 16-36, 18-35, 19-34, 20-33
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 29-4-0.
(lb) - Max Horz 2=338(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 38, 39, 40, 41, 42, 43, 44, 45, 46,
47, 48, 37, 36, 26, 34, 33, 32, 31, 30, 29, 28 except 2=-167(LC 5)
Max Grav All reactions 250 lb or less at joint(s) 38, 39, 40, 41, 42, 43, 44, 45,
46, 47, 48, 37, 36, 26, 35, 34, 33, 32, 31, 30, 29, 28 except 2=281(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-381/234, 3-4=-295/203, 9-10=-49/272, 18-19=-49/272, 25-26=-257/110
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Corner(3) -0-11-0 to 2-1-0, Exterior(2) 2-1-0 to 11-0-0, Corner(3) 11-0-0 to 21-4-0, Exterior(2) 21-4-0 to 30-3-0 zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Provide adequate drainage to prevent water ponding.
5) All plates are 2x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 1-4-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 38, 39, 40, 41, 42,
43, 44, 45, 46, 47, 48, 37, 36, 26, 34, 33, 32, 31, 30, 29, 28 except (jt=lb) 2=167.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
C1
Truss Type
Piggyback Base
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546987
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:02 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-bMzU36XsjxhNd0EO7bw?lblPyU1PcqRctDlsE8zRSah
Scale = 1:75.2
1
2
3
4 5
6
7
8
9
101514131211
30
31
32
33 34
35
36
37
8x12
3x6
4x5
7x10 5x8
3x10
5x6
3x6 5x6
7x10
3x10
3x4
3x4
3x10
5x8
3x10
2-0-8
2-0-8
10-9-0
8-8-8
12-6-0
1-9-0
16-9-8
4-3-8
18-1-0
1-3-8
26-9-8
8-8-8
29-1-0
2-3-8
2-0-8
2-0-8
2-6-10
0-6-2
10-9-0
8-2-6
12-6-0
1-9-0
16-9-8
4-3-8
18-1-0
1-3-8
26-2-8
8-1-8
26-9-8
0-7-0
29-1-0
2-3-8
30-0-0
0-11-0
0-10-1011-7-100-7-101-3-81-0-01-0-011-7-1012.00 12
6.86 12 6.00 12
Plate Offsets (X,Y)-- [1:0-2-0,Edge], [4:0-3-11,Edge], [9:0-1-14,0-3-9]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.67
0.85
0.34
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.19
-0.53
0.23
(loc)
14-15
14-15
9
l/defl
>999
>652
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 160 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
15-16,17-18,19-20,11-21: 2x4 SPF Stud
1-15,9-11: 2x4 SPF 2100F 1.8E
WEBS 2x4 SPF No.2 *Except*
3-15,7-11: 2x4 SPF Stud
SLIDER Left 2x6 SPF No.2 2-6-0, Right 2x4 SPF Stud 2-0-0
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-9-12 oc purlins,
except
2-0-0 oc purlins (5-8-15 max.): 4-5.
BOT CHORD Rigid ceiling directly applied or 8-2-7 oc bracing.
WEBS 1 Row at midpt 3-14, 7-12, 4-12
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=1162/0-3-8, 9=1219/0-3-8
Max Horz 1=-344(LC 5)
Max Uplift 1=-104(LC 7), 9=-144(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-3=-2317/301, 3-4=-1296/256, 4-5=-799/280, 5-7=-1303/251, 7-9=-2389/319
BOT CHORD 14-15=-504/1480, 12-14=-163/793, 11-12=-195/1562, 1-15=-549/1715, 9-11=-161/1836
WEBS 3-14=-716/375, 4-14=0/438, 5-12=0/452, 7-12=-797/316, 3-15=-127/766, 7-11=0/789
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 10-9-0, Exterior(2) 10-9-0 to 22-3-15, Interior(1) 22-3-15 to 30-0-0 zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are 2x4 MT20 unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Bearing at joint(s) 1, 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=104, 9=144.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
DG1
Truss Type
PIGGYBACK BASE GIRDE
Qty
1
Ply
4
17010206 Drake Residence
Job Reference (optional)
I29547011
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:04 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-Xl4FUoZ6FZx5tJOnF0zTq0qlZIhh4eQvLXEzJ1zRSaf
Scale = 1:87.3
1
2
3
4
5 6 7 8 9
10
11
12
13
14 15
30 29
28 27 26 25
24 23 22
21 20 19 18
17 16
38
39
40 41 42 43 44 45 46 47 48 49 50
5x8
10x14 MT18H 10x14 MT18H
3x6
3x6
5x8
2x4
2x4 2x4
2x4
4x6
3x6
5x8
7x10
5x6
5x10
4x5
3x10
4x6
5x10
5x10
5x10
3x10
4x6
3x10
4x6
5x6
7x10
5x6
HGUS26-2
HUS26
HUS26 HUS26
HUS26
HUS26
HUS26 LUS26
LUS26
LUS26 LUS26 LUS26
LUS260-10-0
0-10-0
2-0-8
1-2-8
6-4-12
4-4-4
10-9-0
4-4-4
12-6-0
1-9-0
14-7-12
2-1-12
16-9-8
2-1-12
18-1-0
1-3-8
22-5-4
4-4-4
26-9-8
4-4-4
28-0-0
1-2-8
29-1-0
1-1-0
0-10-0
0-10-0
2-0-8
1-2-8
6-4-12
4-4-4
10-9-0
4-4-4
12-6-0
1-9-0
14-7-12
2-1-12
16-9-8
2-1-12
18-1-0
1-3-8
22-5-4
4-4-4
26-9-8
4-4-4
28-0-0
1-2-8
29-1-0
1-1-0
30-0-0
0-11-0
0-10-1011-7-100-7-101-0-011-7-1012.00 12
Plate Offsets (X,Y)-- [5:1-0-4,0-1-12], [9:1-0-4,0-1-12], [12:0-1-4,0-1-12], [14:0-1-10,0-1-10], [18:0-6-0,0-3-8], [21:0-3-8,0-2-8], [25:0-3-8,0-2-8], [28:0-6-8,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.66
0.93
0.76
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.12
-0.29
0.28
(loc)
19-20
19-20
14
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 1066 lb FT = 20%
GRIP
197/144
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
1-29,25-28,22-24: 2x6 SPF No.2, 18-21: 2x6 SP 2400F 2.0E
14-17: 2x8 SP No.1
WEBS 2x4 SPF Stud *Except*
2-28,5-26,5-25,7-25,7-23,7-21,9-21,9-20,13-18: 2x4 SPF No.2
SLIDER Left 2x4 SPF Stud 0-11-13
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-11-2 oc purlins,
except
2-0-0 oc purlins (6-0-0 max.): 5-9.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
2-2-0 oc bracing: 27-28
6-0-0 oc bracing: 24-25.
REACTIONS.(lb/size)1=7561/Mechanical, 14=8186/0-3-8
Max Horz 1=-344(LC 3)
Max Uplift 1=-1685(LC 5), 14=-1261(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-5232/1193, 2-3=-16480/3869, 3-4=-10781/2325, 4-5=-8314/1712, 5-6=-6047/1261,
6-7=-6038/1258, 7-8=-6018/1144, 8-9=-6027/1144, 9-10=-8372/1482, 10-12=-11157/1714,
12-13=-19124/2751, 13-14=-8555/1276
BOT CHORD 1-30=-1106/3971, 29-30=-224/961, 28-29=-235/1106, 3-28=-1509/5148,
27-28=-3227/12300, 26-27=-1778/7595, 25-26=-1213/5831, 23-24=-77/507,
22-23=-139/488, 20-21=-971/5873, 19-20=-1096/7864, 18-19=-1990/14143,
17-18=-251/1788, 12-18=-952/7276, 16-17=-214/1425, 14-16=-764/5497
WEBS 2-30=-6231/1601, 28-30=-1481/5122, 2-28=-1878/7567, 3-27=-4868/1494,
4-27=-1110/3794, 4-26=-2994/984, 5-26=-1117/4411, 5-25=-209/1274, 23-25=-1115/5873,
7-25=-664/1500, 7-23=-3115/603, 21-23=-1046/5896, 7-21=0/1393, 9-21=-502/1182,
9-20=-601/4498, 10-20=-3369/531, 10-19=-479/4311, 12-19=-6497/1034,
16-18=-815/6021, 13-18=-1144/8140, 13-16=-7265/1011
NOTES-
1) 4-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc, 2x4 - 1 row at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
Attach BC w/ 1/2" diam. bolts (ASTM A-307) in the center of the member w/washers at 4-0-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
5) Provide adequate drainage to prevent water ponding.
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Refer to girder(s) for truss to truss connections.Continued on page 2
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
DG1
Truss Type
PIGGYBACK BASE GIRDE
Qty
1
Ply
4
17010206 Drake Residence
Job Reference (optional)
I29547011
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:04 2017 Page 2 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-Xl4FUoZ6FZx5tJOnF0zTq0qlZIhh4eQvLXEzJ1zRSaf
NOTES-
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=1685, 14=1261.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
11) Use Simpson Strong-Tie HGUS26-2 (20-10d Girder, 6-10d Truss) or equivalent at 3-10-8 from the left end to connect truss(es) to back face of bottom chord.
12) Use Simpson Strong-Tie HUS26 (14-10d Girder, 4-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 5-9-12 from the left end to 15-9-12 to
connect truss(es) to back face of bottom chord.
13) Use Simpson Strong-Tie LUS26 (4-SD9112 Girder, 4-SD9212 Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 17-9-12 from the left end to
25-9-12 to connect truss(es) to back face of bottom chord.
14) Use Simpson Strong-Tie LUS26 (4-10d Girder, 3-10d Truss, Single Ply Girder) or equivalent at 27-9-12 from the left end to connect truss(es) to back face of bottom
chord.
15) Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-5=-60, 5-9=-60, 9-15=-60, 29-31=-20, 25-28=-20, 22-24=-20, 18-21=-20, 17-35=-20
Concentrated Loads (lb)
Vert: 20=-1068(B) 16=-422(B) 40=-1183(B) 41=-1073(B) 42=-1070(B) 43=-1072(B) 44=-1068(B) 45=-1068(B) 46=-1068(B) 47=-1068(B) 48=-1068(B) 49=-1068(B)
50=-1068(B)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
A
Truss
DTB1
Truss Type
GABLE
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547012
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:05 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-?xedi7Zk0s3yVTzzokUiNENsqi5mpAN3ZB_WrTzRSae
Scale = 1:78.2
1
2
3
4
5
6
7
8
9
10
11
16 15 14 13 12
1734 35
3x6
7x10
5x12
5x8
5x12
7x10 7x10
6x8 6x8
3x6
5-1-12
5-1-12
16-10-4
11-8-8
22-0-0
5-1-12
-0-11-0
0-11-0
5-1-12
5-1-12
7-7-2
2-5-6
11-0-0
3-4-14
14-4-14
3-4-14
16-10-4
2-5-6
22-0-0
5-1-12
22-11-0
0-11-0
2-1-813-1-82-1-812.00 12
Plate Offsets (X,Y)-- [2:0-3-8,0-1-12], [3:0-6-0,0-3-4], [3:0-0-0,0-2-12], [9:0-6-0,0-3-4], [9:0-0-0,0-2-12], [10:0-3-8,0-1-12], [13:0-3-8,0-4-12], [15:0-3-8,0-4-12], [23:0-2-8,0-0-0],
[31:0-2-8,0-0-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.95
0.68
0.39
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Attic
in
-0.25
-0.47
0.01
-0.13
(loc)
13-15
13-15
12
13-15
l/defl
>999
>551
n/a
1048
L/d
240
180
n/a
360
PLATES
MT20
Weight: 214 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x10 SP No.1
WEBS 2x4 SPF Stud *Except*
5-7,4-15,8-13: 2x4 SPF No.2
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 9-8-12 oc bracing.
JOINTS 1 Brace at Jt(s): 17
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)16=1642/0-3-8, 12=1642/0-3-8
Max Horz 16=393(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-1696/0, 4-5=-1021/142, 7-8=-1021/142, 8-10=-1696/0, 2-16=-1701/5,
10-12=-1701/5
BOT CHORD 15-16=-381/429, 13-15=0/1033
WEBS 5-17=-1154/175, 7-17=-1154/175, 4-15=-30/802, 8-13=-29/802, 2-15=0/907,
10-13=0/907
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Corner(3) -0-11-0 to 2-1-0, Exterior(2) 2-1-0 to 11-0-0, Corner(3) 11-0-0 to 14-0-0 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 2x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 1-4-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Ceiling dead load (5.0 psf) on member(s). 4-5, 7-8, 5-17, 7-17; Wall dead load (5.0psf) on member(s).4-15, 8-13
8) Bottom chord live load (40.0 psf) and additional bottom chord dead load (10.0 psf) applied only to room. 13-15
9) Attic room checked for L/360 deflection.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
DUG1
Truss Type
ATTIC
Qty
2
Ply
2
17010206 Drake Residence
Job Reference (optional)
I29547013
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:06 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-T8C?vTaMnABp6dY9MR?xvRv1F6ROYeOCorj4NvzRSad
Scale = 1:78.2
1
2
3
4
5
6
7
8
9
10
11
16 15 14 13 12
17
18
19
20 21
22
23
3x6
7x10
5x8
5x6
5x8
2x4 2x4
7x10
2x4
7x10
2x4
6x8
6x8
2x4
3x6
5-1-12
5-1-12
16-10-4
11-8-8
22-0-0
5-1-12
-0-11-0
0-11-0
5-1-12
5-1-12
7-7-2
2-5-6
11-0-0
3-4-14
14-4-14
3-4-14
16-10-4
2-5-6
22-0-0
5-1-12
22-11-0
0-11-0
2-1-813-1-82-1-812.00 12
Plate Offsets (X,Y)-- [2:0-3-8,0-1-12], [10:0-3-8,0-1-12], [13:0-3-8,0-4-12], [15:0-3-8,0-4-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
3-6-0
1.15
1.15
NO
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.91
0.65
0.34
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Attic
in
-0.22
-0.41
0.01
-0.12
(loc)
13-15
13-15
12
13-15
l/defl
>999
>629
n/a
1198
L/d
240
180
n/a
360
PLATES
MT20
Weight: 374 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x10 SP No.1
WEBS 2x4 SPF Stud *Except*
5-7,4-15,8-13: 2x4 SPF No.2
BRACING-
TOP CHORD 2-0-0 oc purlins (6-0-0 max.), except end verticals
(Switched from sheeted: Spacing > 2-0-0).
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
JOINTS 1 Brace at Jt(s): 6, 2, 10, 17
REACTIONS.(lb/size)16=2873/0-3-8, 12=2873/0-3-8
Max Horz 16=688(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-2968/0, 4-5=-1787/178, 7-8=-1787/178, 8-10=-2968/0, 2-16=-2977/0,
10-12=-2977/0
BOT CHORD 15-16=-667/752, 13-15=0/1808, 12-13=-55/290
WEBS 5-17=-2019/181, 7-17=-2019/181, 4-15=-52/1404, 8-13=-51/1404, 2-15=0/1587,
10-13=0/1587
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x10 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 11-0-0, Exterior(2) 11-0-0 to 14-0-0 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Ceiling dead load (5.0 psf) on member(s). 4-5, 7-8, 5-17, 7-17; Wall dead load (5.0psf) on member(s).4-15, 8-13
7) Bottom chord live load (40.0 psf) and additional bottom chord dead load (10.0 psf) applied only to room. 13-15
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
9) Attic room checked for L/360 deflection.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
DV1
Truss Type
ATTIC
Qty
2
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547014
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:07 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-xKmN6pb_YUJgkn6Mw9WASfSCKVnEH4tM1VTdwMzRSac
Scale = 1:78.2
1
2
3
4
5
6
7
8
9
10
11
16 15 14 13 12
17
18
19
20 21
22
23
3x6
7x10
5x8
5x8
5x8
2x4 2x4
7x10
2x4
7x10
2x4
6x8
6x8
2x4
3x6
5-1-12
5-1-12
16-10-4
11-8-8
22-0-0
5-1-12
-0-11-0
0-11-0
5-1-12
5-1-12
7-7-2
2-5-6
11-0-0
3-4-14
14-4-14
3-4-14
16-10-4
2-5-6
22-0-0
5-1-12
22-11-0
0-11-0
2-1-813-1-82-1-812.00 12
Plate Offsets (X,Y)-- [2:0-3-8,0-1-12], [10:0-3-8,0-1-12], [13:0-3-8,0-4-12], [15:0-3-8,0-4-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.95
0.68
0.39
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Attic
in
-0.25
-0.47
0.01
-0.13
(loc)
13-15
13-15
12
13-15
l/defl
>999
>551
n/a
1048
L/d
240
180
n/a
360
PLATES
MT20
Weight: 187 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x10 SP No.1
WEBS 2x4 SPF Stud *Except*
5-7,4-15,8-13: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 9-8-12 oc bracing.
JOINTS 1 Brace at Jt(s): 17
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)16=1642/0-3-8, 12=1642/0-3-8
Max Horz 16=393(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-1696/0, 4-5=-1021/102, 7-8=-1021/102, 8-10=-1696/0, 2-16=-1701/0,
10-12=-1701/0
BOT CHORD 15-16=-381/429, 13-15=0/1033
WEBS 5-17=-1154/103, 7-17=-1154/103, 4-15=-30/802, 8-13=-29/802, 2-15=0/907,
10-13=0/907
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 11-0-0, Exterior(2) 11-0-0 to 14-0-0 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Ceiling dead load (5.0 psf) on member(s). 4-5, 7-8, 5-17, 7-17; Wall dead load (5.0psf) on member(s).4-15, 8-13
5) Bottom chord live load (40.0 psf) and additional bottom chord dead load (10.0 psf) applied only to room. 13-15
6) Attic room checked for L/360 deflection.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
DW1
Truss Type
GABLE
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547015
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:07 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-xKmN6pb_YUJgkn6Mw9WASfSE?VnQH3eM1VTdwMzRSac
Scale = 1:84.1
1
2
3
4
5
6
7
8
9
10
11
16 15 14 13 12
17
38
39
40 41
42
43
3x6
7x10
5x16
5x6
5x16
3x4 3x4
7x10 7x10
7x10
7x10
3x6
5-1-12
5-1-12
18-10-4
13-8-8
24-0-0
5-1-12
-0-11-0
0-11-0
5-1-12
5-1-12
7-7-2
2-5-6
12-0-0
4-4-14
16-4-14
4-4-14
18-10-4
2-5-6
24-0-0
5-1-12
24-11-0
0-11-0
2-1-814-1-82-1-812.00 12
Plate Offsets (X,Y)-- [2:0-3-8,0-2-8], [3:0-7-12,0-3-4], [3:0-0-0,0-2-12], [9:0-7-12,0-3-4], [9:0-0-0,0-2-12], [10:0-3-8,0-2-8], [13:0-3-8,0-4-12], [15:0-3-8,0-4-12], [23:0-2-8,0-0-0],
[33:0-2-8,0-0-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.78
0.67
0.47
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Attic
in
-0.32
-0.60
0.01
-0.21
(loc)
13-15
13-15
12
13-15
l/defl
>883
>478
n/a
793
L/d
240
180
n/a
360
PLATES
MT20
Weight: 247 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x6 SP 2400F 2.0E *Except*
1-3,9-11: 2x6 SPF No.2
BOT CHORD 2x10 SP No.1
WEBS 2x4 SPF No.2 *Except*
2-15,10-13,6-17: 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-0-12 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 8-3-4 oc bracing.
JOINTS 1 Brace at Jt(s): 17
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)16=1832/0-3-8, 12=1832/0-3-8
Max Horz 16=-423(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-2004/0, 4-5=-1211/100, 7-8=-1211/100, 8-10=-2004/0, 2-16=-1994/0,
10-12=-1994/0
BOT CHORD 15-16=-412/470, 13-15=0/1232
WEBS 5-17=-1289/92, 7-17=-1289/92, 4-15=-4/981, 8-13=-3/981, 2-15=0/1092, 10-13=0/1092
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 12-0-0, Exterior(2) 12-0-0 to 15-0-0 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 2x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 1-4-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Ceiling dead load (5.0 psf) on member(s). 4-5, 7-8, 5-17, 7-17; Wall dead load (5.0psf) on member(s).4-15, 8-13
8) Bottom chord live load (40.0 psf) and additional bottom chord dead load (10.0 psf) applied only to room. 13-15
9) Attic room checked for L/360 deflection.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
DX1
Truss Type
ATTIC
Qty
7
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547016
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:08 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-PWKlK9cdJnRXMxhYUs1P?s?Plv7f0WuVG9CASozRSab
Scale = 1:84.1
1
2
3
4
5
6
7
8
9
10
11
16 15 14 13 12
17
18
19
20 21
22
23
3x6
7x10
5x12
5x6
5x12
3x4 3x4
7x10
2x4
7x10
2x4
7x10
7x10
2x4
3x6
5-1-12
5-1-12
18-10-4
13-8-8
24-0-0
5-1-12
-0-11-0
0-11-0
5-1-12
5-1-12
7-7-2
2-5-6
12-0-0
4-4-14
16-4-14
4-4-14
18-10-4
2-5-6
24-0-0
5-1-12
24-11-0
0-11-0
2-1-814-1-82-1-812.00 12
Plate Offsets (X,Y)-- [2:0-3-8,0-2-8], [10:0-3-8,0-2-8], [13:0-3-8,0-4-12], [15:0-3-8,0-4-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.78
0.67
0.47
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Attic
in
-0.32
-0.60
0.01
-0.21
(loc)
13-15
13-15
12
13-15
l/defl
>883
>478
n/a
793
L/d
240
180
n/a
360
PLATES
MT20
Weight: 217 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x6 SP 2400F 2.0E *Except*
1-3,9-11: 2x6 SPF No.2
BOT CHORD 2x10 SP No.1
WEBS 2x4 SPF No.2 *Except*
2-15,10-13,6-17: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-0-12 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 8-3-4 oc bracing.
JOINTS 1 Brace at Jt(s): 17
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)16=1832/0-3-8, 12=1832/0-3-8
Max Horz 16=-423(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-2004/0, 4-5=-1211/100, 7-8=-1211/100, 8-10=-2004/0, 2-16=-1994/0,
10-12=-1994/0
BOT CHORD 15-16=-412/470, 13-15=0/1232
WEBS 5-17=-1289/92, 7-17=-1289/92, 4-15=-4/981, 8-13=-3/981, 2-15=0/1092, 10-13=0/1092
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 12-0-0, Exterior(2) 12-0-0 to 15-0-0 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Ceiling dead load (5.0 psf) on member(s). 4-5, 7-8, 5-17, 7-17; Wall dead load (5.0psf) on member(s).4-15, 8-13
5) Bottom chord live load (40.0 psf) and additional bottom chord dead load (10.0 psf) applied only to room. 13-15
6) Attic room checked for L/360 deflection.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
DYG1
Truss Type
ATTIC
Qty
2
Ply
2
17010206 Drake Residence
Job Reference (optional)
I29547017
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:09 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-uju8XVcF45ZOz5Gk1aYeX4XZUJTHl_2eUpyk_EzRSaa
Scale = 1:84.1
1
2
3
4
5
6
7
8
9
10
11
16 15 14 13 12
17
20
18
21 22
19
23
3x6
6x8
5x10
5x6
5x10
2x4 2x4
7x10
2x4
7x10
2x4
6x8
6x8
2x4
3x6
5-1-12
5-1-12
18-10-4
13-8-8
24-0-0
5-1-12
-0-11-0
0-11-0
5-1-12
5-1-12
7-7-2
2-5-6
12-0-0
4-4-14
16-4-14
4-4-14
18-10-4
2-5-6
24-0-0
5-1-12
24-11-0
0-11-0
2-1-814-1-82-1-812.00 12
Plate Offsets (X,Y)-- [2:0-3-8,0-1-12], [10:0-3-8,0-1-12], [13:0-3-8,0-4-12], [15:0-3-8,0-4-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
3-6-0
1.15
1.15
NO
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.78
0.64
0.41
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Attic
in
-0.28
-0.52
0.01
-0.18
(loc)
13-15
13-15
12
13-15
l/defl
>999
>546
n/a
907
L/d
240
180
n/a
360
PLATES
MT20
Weight: 433 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x6 SP 2400F 2.0E *Except*
1-3,9-11: 2x6 SPF No.2
BOT CHORD 2x10 SP No.1
WEBS 2x4 SPF No.2 *Except*
2-15,10-13,6-17: 2x4 SPF Stud
BRACING-
TOP CHORD 2-0-0 oc purlins (6-0-0 max.), except end verticals
(Switched from sheeted: Spacing > 2-0-0).
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
JOINTS 1 Brace at Jt(s): 6, 2, 10, 17
REACTIONS.(lb/size)16=3205/0-3-8, 12=3205/0-3-8
Max Horz 16=-740(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-3508/0, 4-5=-2120/174, 5-6=-323/157, 6-7=-323/154, 7-8=-2120/174,
8-10=-3508/0, 2-16=-3489/0, 10-12=-3489/0
BOT CHORD 15-16=-721/823, 13-15=0/2156, 12-13=-47/332
WEBS 5-17=-2255/161, 7-17=-2255/161, 4-15=-6/1717, 8-13=-5/1717, 2-15=0/1911,
10-13=0/1911
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x10 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 12-0-0, Exterior(2) 12-0-0 to 15-0-0 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Ceiling dead load (5.0 psf) on member(s). 4-5, 7-8, 5-17, 7-17; Wall dead load (5.0psf) on member(s).4-15, 8-13
7) Bottom chord live load (40.0 psf) and additional bottom chord dead load (10.0 psf) applied only to room. 13-15
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
9) Attic room checked for L/360 deflection.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
E1
Truss Type
Roof Special
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546989
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:09 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-uju8XVcF45ZOz5Gk1aYeX4XaWJVtlxbeUpyk_EzRSaa
Scale = 1:74.7
1
2
3 4 5 6 7 8
16 15 14
13 12 11
10
9
17
18
19 20
2x4
5x6
8x10
6x8 3x10 5x8
3x6
7x10
2x4 2x4
2x4
7x10 5x6
3x10
5x8
1-10-0
1-10-0
10-2-0
8-4-0
14-11-8
4-9-8
19-9-0
4-9-8
27-6-0
7-9-0
1-10-0
1-10-0
10-2-0
8-4-0
14-11-8
4-9-8
19-9-0
4-9-8
27-6-0
7-9-0
2-3-1010-7-1012-7-1011-7-101-0-012-7-1012.00 12
Plate Offsets (X,Y)-- [3:0-2-5,0-0-15], [4:0-2-15,0-2-7], [4:0-1-5,0-2-7], [10:0-4-12,Edge], [14:0-4-12,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.71
0.54
0.63
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.15
-0.39
0.04
(loc)
14-15
14-15
9
l/defl
>999
>834
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 197 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
2-4: 2x6 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
1-16,1-15,2-15,12-14,10-12: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (5-8-10 max.): 1-2, 4-8.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. Except:
1 Row at midpt 6-10
WEBS 1 Row at midpt 8-9, 2-14, 5-12, 5-10, 8-10
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)16=1088/Mechanical, 9=1088/Mechanical
Max Horz 16=409(LC 6)
Max Uplift 16=-86(LC 7), 9=-250(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-16=-1139/88, 1-2=-900/98, 2-3=-1149/206, 3-4=-616/235, 4-5=-690/247,
5-6=-558/252, 6-8=-565/253, 8-9=-1013/282
BOT CHORD 15-16=-509/314, 14-15=-552/972, 3-14=-74/362, 6-10=-454/227
WEBS 1-15=-185/1470, 2-15=-996/277, 2-14=-282/206, 12-14=-264/657, 5-14=-251/253,
5-12=-285/214, 10-12=-200/621, 8-10=-255/983
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-1-12 to 1-10-0, Interior(1) 1-10-0 to 10-4-2, Exterior(2) 10-4-2 to 13-4-2 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16 except (jt=lb)
9=250.
6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
F1
Truss Type
Piggyback Base
Qty
4
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546991
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:10 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-MvSWlrdtrPhFbErwbH3t4H4rpjpOULBojThHWhzRSaZ
Scale = 1:75.2
1
2
3
4 5
6
7
8
9 10
22 21 20
19 18 17
16 15 14
13 12 11
23
24
25 26
27
2x4
5x8
5x6
7x10 5x8
4x5
2x4
5x10
3x4
2x4
7x10
2x4
2x4 2x4
2x4
5x12
5x8
5x10 5x8
5x6
5x6
5x8
1-10-0
1-10-0
7-10-0
6-0-0
10-2-0
2-4-0
16-5-8
6-3-8
18-6-0
2-0-8
20-6-8
2-0-8
24-3-8
3-9-0
27-6-0
3-2-8
1-10-0
1-10-0
7-10-0
6-0-0
10-2-0
2-4-0
15-6-0
5-4-0
18-6-0
3-0-0
24-3-8
5-9-8
27-6-0
3-2-8
1-3-109-7-100-10-212-7-102-10-22-0-012-7-1012.00 12
Plate Offsets (X,Y)-- [4:0-8-4,0-1-12], [13:0-2-8,0-2-8], [17:0-4-12,0-2-4], [20:0-4-4,0-2-8], [21:0-3-8,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.36
0.59
0.80
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.07
-0.23
0.10
(loc)
20-21
20-21
11
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 207 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud *Except*
7-15,7-17,7-13,4-18,5-18,5-17,4-20: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-5-15 oc purlins,
except end verticals, and 2-0-0 oc purlins (4-6-6 max.): 1-2, 4-5,
9-10.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 7-15, 4-18, 5-18
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)22=1088/Mechanical, 11=1088/Mechanical
Max Horz 22=-340(LC 5)
Max Uplift 22=-101(LC 7), 11=-107(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-22=-1050/109, 1-2=-1608/203, 2-3=-1365/213, 3-4=-1314/421, 4-5=-682/250,
5-6=-1058/354, 6-7=-1152/304, 7-8=-1279/345, 8-9=-1325/221, 9-10=-1120/168,
10-11=-1056/156
BOT CHORD 21-22=-301/317, 20-21=-285/1748, 3-20=-308/280, 17-18=-93/710, 12-13=-174/1171
WEBS 7-15=-981/113, 15-17=-90/1030, 13-15=-55/732, 7-13=-189/739, 9-13=-333/115,
18-20=-105/727, 9-12=-894/174, 10-12=-184/1464, 2-21=-983/223, 1-21=-235/1862,
2-20=-870/227, 5-17=-182/549, 4-20=-278/811
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-1-12 to 1-10-0, Interior(1) 1-10-0 to 10-2-0, Exterior(2) 10-2-0 to 18-6-0, Interior(1) 18-6-0 to 24-3-8 zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
22=101, 11=107.
7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
F2
Truss Type
Piggyback Base
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547020
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:11 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-q5?uyBeVbip6DOQ79_b6cUdyQ79dDnBxy7Rr37zRSaY
Scale = 1:71.8
1
2
3
4 5
6
7 8
18 17 16
15 14 13
12
11 10 9
19
20
21 22
23
24
2x4
5x8
5x6
7x10 6x8
5x8 2x4
3x6
7x10
3x4
2x4
3x10
3x6
5x8 5x8 3x10
3x6
5x12
1-10-0
1-10-0
7-10-0
6-0-0
10-2-0
2-4-0
15-6-0
5-4-0
16-5-8
0-11-8
24-3-8
7-10-0
27-6-0
3-2-8
1-10-0
1-10-0
7-10-0
6-0-0
10-2-0
2-4-0
15-6-0
5-4-0
16-5-8
0-11-8
24-3-8
7-10-0
27-6-0
3-2-8
1-3-109-7-100-10-212-7-103-10-23-0-012-7-1012.00 12
Plate Offsets (X,Y)-- [4:0-8-4,0-1-12], [5:0-6-4,0-1-12], [7:0-5-4,0-3-0], [12:0-8-12,0-4-0], [16:0-3-4,0-3-0], [17:0-3-8,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.62
0.59
0.88
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.12
-0.33
0.09
(loc)
10-11
10-11
9
l/defl
>999
>975
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 192 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud *Except*
4-16,4-14,5-14,5-13,6-13,10-12,7-12: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-11-6 oc purlins,
except end verticals, and 2-0-0 oc purlins (4-6-6 max.): 1-2, 4-5, 7-8.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 14-15.
WEBS 1 Row at midpt 4-14, 5-14, 6-13
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)18=1088/Mechanical, 9=1088/Mechanical
Max Horz 18=-364(LC 5)
Max Uplift 18=-99(LC 7), 9=-109(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-18=-1050/106, 1-2=-1608/205, 2-3=-1365/214, 3-4=-1314/424, 4-5=-678/252,
5-6=-1232/557, 6-7=-1286/230
BOT CHORD 17-18=-320/341, 16-17=-305/1749, 3-16=-309/281, 13-14=-109/720, 12-13=-102/764,
6-12=-8/276, 9-10=-149/898
WEBS 1-17=-230/1863, 2-17=-983/220, 2-16=-870/227, 14-16=-129/716, 4-16=-283/833,
5-13=-465/869, 6-13=-744/469, 10-12=-167/863, 7-9=-1372/179
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-1-12 to 1-10-0, Interior(1) 1-10-0 to 10-2-0, Exterior(2) 10-2-0 to 18-6-0, Interior(1) 18-6-0 to 24-3-8 zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18 except (jt=lb)
9=109.
7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
G1
Truss Type
Piggyback Base
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546992
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:12 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-IIZGAXf7M0yzqY?Jji6L9i9D0WV3yIC5AnAObZzRSaX
Scale = 1:75.7
1
2
3
4 5
6
7
8
9 10
22 21 20 19 18
17
16 15 14
13 12 11
23
24
2526
27
2x4
5x8
4x5
4x5 5x8
5x12 2x4
3x6
3x6
3x10
2x4 2x4
2x4
6x8
5x8
4x5
3x4
7x10
5x12
5x8
5x10
2x4
1-0-8
1-0-8
10-2-0
9-1-8
15-6-0
5-4-0
16-5-8
0-11-8
18-6-0
2-0-8
20-6-8
2-0-8
24-3-8
3-9-0
27-6-0
3-2-8
1-0-8
1-0-8
5-7-4
4-6-12
10-2-0
4-6-12
15-6-0
5-4-0
16-5-8
0-11-8
18-6-0
2-0-8
20-6-8
2-0-8
24-3-8
3-9-0
27-6-0
3-2-8
1-6-210-7-101-10-212-7-102-10-21-0-012-7-1012.00 12
Plate Offsets (X,Y)-- [4:0-3-4,0-1-12], [5:0-6-4,0-1-12], [13:0-2-8,0-2-8], [17:0-7-12,0-5-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.25
0.64
0.58
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.17
-0.45
0.11
(loc)
20-21
20-21
11
l/defl
>999
>729
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 205 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud *Except*
3-20,4-20,5-20,5-18,6-18,7-17,7-15,7-13: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-11-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 1-2, 4-5,
9-10.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
9-9-11 oc bracing: 21-22
6-0-0 oc bracing: 16-17,13-14.
WEBS 1 Row at midpt 5-20, 6-18, 7-15
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)22=1088/Mechanical, 11=1088/Mechanical
Max Horz 22=347(LC 6)
Max Uplift 22=-99(LC 7), 11=-105(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-22=-1190/2, 1-2=-747/32, 2-3=-1265/193, 3-4=-1079/270, 4-5=-687/251,
5-6=-931/324, 6-7=-1177/318, 7-8=-1280/338, 8-9=-1326/216
BOT CHORD 21-22=-330/332, 20-21=-258/840, 18-20=-105/718, 17-18=-107/748, 6-17=-141/631,
12-13=-179/1171, 11-12=-176/1175
WEBS 1-21=-27/1340, 2-21=-965/236, 4-20=-67/438, 5-18=-169/444, 6-18=-477/150,
15-17=-105/1037, 7-17=-174/286, 7-15=-1049/131, 13-15=-59/731, 7-13=-189/742,
9-13=-333/115, 9-11=-1508/195, 3-21=-39/278
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-1-12 to 1-0-8, Interior(1) 1-0-8 to 10-2-0, Exterior(2) 10-2-0 to 18-6-0, Interior(1) 18-6-0 to 24-3-8 zone; cantilever
left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 22 except (jt=lb)
11=105.
7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
H1
Truss Type
Half Hip
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546993
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:13 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-mU7eNsgl7K4pSiaVGPdaiviIpwswhlcEPRwx7?zRSaW
Scale = 1:59.4
1
2
3 4 5 6 7 8
15 14
13 12 11
10 9
19
20
21 22
5x6
5x8 3x10 5x6
3x4
5x12
2x4
2x4 2x4
3x4
7x10 3x4
2x4
3x10
5x8
8-2-0
8-2-0
10-2-0
2-0-0
14-11-8
4-9-8
19-9-0
4-9-8
27-6-0
7-9-0
4-2-7
4-2-7
8-2-0
3-11-9
10-2-0
2-0-0
14-11-8
4-9-8
19-9-0
4-9-8
27-6-0
7-9-0
0-5-108-7-1010-7-109-7-101-0-010-7-1012.00 12
Plate Offsets (X,Y)-- [1:0-0-0,0-0-11], [3:0-6-4,0-1-12], [9:Edge,0-1-8], [10:0-4-12,Edge], [14:0-3-4,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.63
0.53
0.63
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.14
-0.35
0.04
(loc)
9-10
9-10
9
l/defl
>999
>930
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 182 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
2-15,12-14,10-12: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-0-1 oc purlins,
except end verticals, and 2-0-0 oc purlins (5-10-1 max.): 3-8.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. Except:
1 Row at midpt 4-14, 6-10
WEBS 1 Row at midpt 8-9, 5-12, 5-10
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=1097/0-3-8, 9=1092/Mechanical
Max Horz 1=333(LC 6)
Max Uplift 1=-92(LC 7), 9=-237(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1339/230, 2-3=-1176/265, 3-4=-842/254, 4-5=-843/255, 5-6=-678/243,
6-8=-688/244, 8-9=-1015/271
BOT CHORD 1-15=-468/896, 14-15=-346/763, 6-10=-441/236
WEBS 3-15=-51/379, 3-14=-256/318, 12-14=-275/761, 5-12=-353/214, 10-12=-189/735,
8-10=-245/1055
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 8-2-0, Exterior(2) 8-2-0 to 12-4-15 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb)
9=237.
6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
I1
Truss Type
Piggyback Base
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546994
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:14 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-Egh1aCgNudCg4s9iq78pE7FPBKBJQ9BOe5fVfSzRSaV
Scale = 1:70.8
1
2
3
4 5 6 7
16 15
14
13 12
11 10
9
8
17
18
19 20
2x4
5x8
5x6
5x8 3x10 5x8
3x6
7x10
3x4
2x4
5x10
3x4 3x10
5x8
3x4
5x8
1-10-0
1-10-0
7-10-0
6-0-0
10-2-0
2-4-0
18-8-4
8-6-4
27-6-0
8-9-12
1-10-0
1-10-0
7-10-0
6-0-0
10-2-0
2-4-0
18-8-4
8-6-4
27-6-0
8-9-12
1-3-109-7-1012-7-103-0-012.00 12
Plate Offsets (X,Y)-- [4:0-3-0,0-2-8], [12:0-2-12,0-2-0], [14:0-3-8,0-3-0], [15:0-3-8,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.85
0.59
0.80
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.14
-0.36
0.05
(loc)
8-10
8-10
8
l/defl
>999
>906
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 181 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud *Except*
7-8: 2x4 SPF 2100F 1.8E, 4-14,10-12,5-12,5-10,7-10: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-5-15 oc purlins,
except end verticals, and 2-0-0 oc purlins (4-6-5 max.): 1-2, 4-7.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. Except:
1 Row at midpt 4-12
WEBS 1 Row at midpt 7-8, 5-12, 5-10, 7-10
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)16=1088/Mechanical, 8=1088/Mechanical
Max Horz 16=405(LC 6)
Max Uplift 16=-87(LC 7), 8=-235(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-16=-1050/104, 1-2=-1609/187, 2-3=-1365/205, 3-4=-1288/387, 4-5=-682/256,
5-7=-573/275, 7-8=-1014/265
BOT CHORD 15-16=-508/321, 14-15=-599/1750, 3-14=-274/269, 4-12=-197/262
WEBS 1-15=-226/1864, 2-15=-984/217, 2-14=-872/220, 12-14=-328/703, 4-14=-387/818,
10-12=-258/561, 5-10=-735/381, 7-10=-223/978
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-1-12 to 1-10-0, Interior(1) 1-10-0 to 10-2-0, Exterior(2) 10-2-0 to 13-2-0 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16 except (jt=lb)
8=235.
6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
J1
Truss Type
Half Hip
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546995
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:14 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-Egh1aCgNudCg4s9iq78pE7FTtKE_QEkOe5fVfSzRSaV
Scale = 1:53.3
1
2 3 4 5 6 7
14 13
12 11 10
9
8
18
19
20 21
5x8
5x8 3x6 3x10
3x4
5x10
2x4
2x4 2x4
3x4
8x12 2x4
5x8
5x8
6-2-0
6-2-0
10-2-0
4-0-0
14-11-8
4-9-8
19-9-0
4-9-8
27-6-0
7-9-0
6-2-0
6-2-0
10-2-0
4-0-0
14-11-8
4-9-8
19-9-0
4-9-8
27-6-0
7-9-0
0-5-106-7-108-7-107-7-101-0-08-7-1012.00 12
Plate Offsets (X,Y)-- [1:0-2-8,0-1-8], [2:0-6-4,0-1-12], [13:0-2-12,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.61
0.42
0.51
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.14
-0.35
0.04
(loc)
8-9
8-9
8
l/defl
>999
>928
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 158 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
2-14,11-13,9-11: 2x4 SPF Stud
WEDGE
Left: 2x8 SP No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-11-3 oc purlins,
except end verticals, and 2-0-0 oc purlins (5-2-11 max.): 2-7.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
9-11-1 oc bracing: 1-14
6-0-0 oc bracing: 10-11.
WEBS 1 Row at midpt 7-8, 4-11, 4-9
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=1099/0-3-8, 8=1090/Mechanical
Max Horz 1=257(LC 6)
Max Uplift 1=-100(LC 7), 8=-251(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1320/210, 2-3=-1109/254, 3-4=-1108/254, 4-6=-857/277, 6-7=-873/282,
7-8=-1012/300
BOT CHORD 1-14=-319/832, 13-14=-318/836, 3-13=-272/180, 6-9=-438/243
WEBS 2-13=-248/500, 11-13=-262/951, 4-13=-160/358, 4-11=-462/210, 9-11=-188/893,
7-9=-258/1175
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 6-2-0, Exterior(2) 6-2-0 to 10-3-12 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=100, 8=251.
6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
K1
Truss Type
Half Hip
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29546996
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:15 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-isFPoYh0fxKXh0kuOqf3nKnZckag9gJXtlP2CuzRSaU
Scale = 1:47.5
1
2 3 4 5 6 7
14 13
12 11 10
9
8
18
19 20 21 22
4x5
5x8 3x6 3x10
3x4
5x10
2x4
2x4 2x4
3x4
8x12
2x4
5x8
3x10
4-2-0
4-2-0
10-2-0
6-0-0
14-11-8
4-9-8
19-9-0
4-9-8
27-6-0
7-9-0
4-2-0
4-2-0
10-2-0
6-0-0
14-11-8
4-9-8
19-9-0
4-9-8
27-6-0
7-9-0
0-5-104-7-106-7-105-7-101-0-06-7-1012.00 12
Plate Offsets (X,Y)-- [1:0-5-0,0-0-7], [2:0-6-4,0-1-12], [13:0-3-4,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.93
0.39
0.55
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.14
-0.37
0.05
(loc)
8-9
8-9
8
l/defl
>999
>876
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 139 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
3-12,6-10: 2x4 SPF Stud
WEBS 2x4 SPF Stud *Except*
7-9: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-11-7 oc purlins,
except end verticals, and 2-0-0 oc purlins (4-1-14 max.): 2-7.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 10-11.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=1096/0-3-8, 8=1093/Mechanical
Max Horz 1=180(LC 6)
Max Uplift 1=-131(LC 6), 8=-280(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1383/251, 2-3=-1661/428, 3-4=-1643/423, 4-6=-1178/363, 6-7=-1203/371,
7-8=-1014/325
BOT CHORD 1-14=-273/911, 13-14=-271/915, 3-13=-365/216, 6-9=-439/249
WEBS 2-13=-325/914, 11-13=-284/1259, 4-13=-177/630, 4-11=-643/226, 9-11=-220/1164,
7-9=-363/1425
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 4-2-0, Exterior(2) 4-2-0 to 8-4-15 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=131, 8=280.
6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
L1
Truss Type
Common
Qty
7
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547026
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:15 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-isFPoYh0fxKXh0kuOqf3nKnjZkca9iQXtlP2CuzRSaU
Scale = 1:69.4
12
3
4
5
6
7
11 10 9 8
18
19
20 21
22
23
3x6
4x5
4x6
3x10
3x6 3x10
3x6
2x4
3x6
2x4
5-5-15
5-5-15
10-11-0
5-5-1
16-4-1
5-5-1
22-0-0
5-7-15
-0-11-0
0-11-0
5-5-15
5-5-15
10-11-0
5-5-1
16-4-1
5-5-1
22-0-0
5-7-15
0-7-1011-6-100-5-1012.00 12
Plate Offsets (X,Y)-- [2:0-3-8,Edge], [2:0-0-13,0-3-3], [2:0-0-7,0-0-7], [7:0-6-0,0-0-11]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.29
0.27
0.42
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.04
-0.08
0.03
(loc)
11-17
10-11
7
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 106 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
6-8,3-11: 2x4 SPF Stud
WEDGE
Left: 2x6 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-6-1 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)7=882/0-3-8, 2=933/0-3-8
Max Horz 2=341(LC 6)
Max Uplift 7=-91(LC 8), 2=-127(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1029/151, 3-5=-746/235, 5-6=-747/238, 6-7=-1051/151
BOT CHORD 2-11=-136/656, 10-11=-136/656, 8-10=0/668, 7-8=0/668
WEBS 5-10=-190/583, 6-10=-343/202, 3-10=-328/209
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 10-11-0, Exterior(2) 10-11-0 to 13-11-0 zone; cantilever left and right exposed ;
end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7 except (jt=lb)
2=127.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
M1
Truss Type
Common
Qty
2
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547027
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:16 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-A3pn?uieQFSOJ9J4yYAIJYKuJ8xpu9Zg5P8bkKzRSaT
Scale = 1:69.2
1
2
3
4
5
9 8 7 6
16
17
18 19
20
21
4x6 3x6
4x5
3x6
2x4 3x10
3x6
2x4 5x8 5-5-15
5-5-15
10-11-0
5-5-1
16-4-1
5-5-1
22-0-0
5-7-15
5-5-15
5-5-15
10-11-0
5-5-1
16-4-1
5-5-1
22-0-0
5-7-15
0-7-1011-6-100-5-1012.00 12
Plate Offsets (X,Y)-- [1:0-3-8,Edge], [1:0-0-13,0-3-3], [1:0-0-7,0-0-7], [5:0-6-0,0-0-11]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.29
0.27
0.42
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.04
-0.07
0.03
(loc)
9-15
8-9
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 104 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
4-6,2-9: 2x4 SPF Stud
WEDGE
Left: 2x6 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-6-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)5=883/0-3-8, 1=877/0-3-8
Max Horz 1=-327(LC 5)
Max Uplift 5=-91(LC 8), 1=-86(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1034/160, 2-3=-748/239, 3-4=-749/238, 4-5=-1053/152
BOT CHORD 1-9=-137/661, 8-9=-137/661, 6-8=0/670, 5-6=0/670
WEBS 3-8=-192/586, 4-8=-343/202, 2-8=-333/215
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 10-11-0, Exterior(2) 10-11-0 to 13-11-0 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 1.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
NB1
Truss Type
GABLE
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547000
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:17 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-fFN9DEjGBYaFxJtHVFiXslt6NXLUdgAqK3u9GnzRSaS
Scale = 1:72.5
1
2
3
4
56
7
8
9
10
11
12
13
14
15
16
17
18
19
35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20
36
3x6
4x5
3x4 3x6
3x6
22-0-0
22-0-0
-0-11-0
0-11-0
10-11-0
10-11-0
22-0-0
11-1-0
0-7-1011-6-100-5-1012.00 12
Plate Offsets (X,Y)-- [2:0-0-13,0-3-3], [2:0-0-7,0-0-7], [5:0-2-8,Edge], [24:0-2-0,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-S
0.08
0.05
0.15
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
0.01
(loc)
1
1
19
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 166 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud *Except*
11-28,10-29,9-30,12-27,13-26: 2x4 SPF No.2
WEDGE
Left: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 11-28, 10-29, 9-30, 12-27, 13-26
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 22-0-0.
(lb) - Max Horz 2=344(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 19, 29, 30, 31, 32, 33, 34, 27, 26,
25, 23, 22, 21 except 2=-133(LC 5), 35=-104(LC 7), 20=-114(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 19, 28, 29, 30, 31, 32, 33, 34,
35, 27, 26, 25, 23, 22, 21, 20 except 2=272(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-374/197, 3-4=-285/170, 18-19=-280/103
WEBS 11-28=-257/0
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Corner(3) -0-11-0 to 2-1-0, Exterior(2) 2-1-0 to 10-11-0, Corner(3) 10-11-0 to 13-11-0 zone; cantilever left and right exposed ;
end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 2x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 29, 30, 31, 32,
33, 34, 27, 26, 25, 23, 22, 21 except (jt=lb) 2=133, 35=104, 20=114.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
O1
Truss Type
Piggyback Base
Qty
6
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547029
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:18 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-7RwXQajuysi6YTST3zDmPzP6Qxc_M5nzZjdipDzRSaR
Scale = 1:70.2
1 2
3 4 5
10 9 8 7 6
11
12
13
14 15 16
6x8
3x6 3x4 3x6 3x4
2x4
5x8
5x8
6x8
7-0-8
7-0-8
13-11-8
6-11-0
20-10-8
6-11-0
-0-11-0
0-11-0
7-0-8
7-0-8
13-11-8
6-11-0
20-10-8
6-11-0
5-3-812-4-012.00 12
Plate Offsets (X,Y)-- [2:0-3-8,Edge], [3:0-6-4,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.83
0.35
0.31
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.07
-0.17
-0.01
(loc)
9-10
9-10
6
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 139 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
5-6: 2x4 SPF 2100F 1.8E, 2-10: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5.
BOT CHORD Rigid ceiling directly applied or 7-6-1 oc bracing.
WEBS 1 Row at midpt 5-6, 3-9, 3-8, 4-8, 5-8
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)6=822/0-5-0, 10=889/0-5-8
Max Horz 10=471(LC 6)
Max Uplift 6=-275(LC 6), 10=-79(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-621/191, 3-4=-341/237, 4-5=-341/237, 5-6=-762/333, 2-10=-824/214
BOT CHORD 9-10=-612/365, 8-9=-387/331
WEBS 4-8=-469/257, 5-8=-315/682, 2-9=-147/368
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 7-0-8, Exterior(2) 7-0-8 to 11-3-7 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10 except (jt=lb)
6=275.
5) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
P1
Truss Type
Piggyback Base
Qty
4
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547002
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:18 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-7RwXQajuysi6YTST3zDmPzP8pxc_M5pzZjdipDzRSaR
Scale = 1:70.2
1
2 3 4
9 8 7 6 5
10
11
12
13 14 15
6x8
8x10
3x6 3x4 3x6 3x4
2x4
5x8
5x8
7-0-8
7-0-8
13-11-8
6-11-0
20-10-8
6-11-0
7-0-8
7-0-8
13-11-8
6-11-0
20-10-8
6-11-0
5-3-812-4-012.00 12
Plate Offsets (X,Y)-- [1:Edge,0-1-7], [2:0-8-4,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.68
0.35
0.31
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.07
-0.17
-0.01
(loc)
8-9
8-9
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 137 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
4-5: 2x4 SPF 2100F 1.8E, 1-9: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-4.
BOT CHORD Rigid ceiling directly applied or 7-8-13 oc bracing.
WEBS 1 Row at midpt 4-5, 2-8, 2-7, 3-7, 4-7
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)5=823/0-5-0, 9=823/0-5-8
Max Horz 9=454(LC 6)
Max Uplift 5=-272(LC 6), 9=-52(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-618/169, 2-3=-342/231, 3-4=-342/231, 4-5=-763/328, 1-9=-760/182
BOT CHORD 8-9=-577/376, 7-8=-382/334
WEBS 3-7=-467/258, 4-7=-308/683, 1-8=-155/378
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 7-0-8, Exterior(2) 7-0-8 to 11-3-7 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9 except (jt=lb)
5=272.
5) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
PB1
Truss Type
Piggyback
Qty
7
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547031
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:19 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-beUwewkWj9qzAd1fdgk?xAyOgL?Q5ZX7nNNGLfzRSaQ
Scale = 1:61.7
12
3
4
5
6
7
11 10 9 8
12
13
14 15
3x6
3x4
3x4
3x4
2x4
2x4
2x4
2x4
2x4
2x4
13-10-0
13-10-0
10-3-8
10-3-8
13-10-0
3-6-8
0-5-310-3-80-1-86-7-80-1-812.00 12
Plate Offsets (X,Y)-- [2:0-2-6,0-1-8], [5:0-3-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-S
0.35
0.14
0.22
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
0.00
0.00
(loc)
1
1
8
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 65 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud *Except*
6-9: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 6-9
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 13-3-5.
(lb) - Max Horz 2=395(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) except 8=-164(LC 8), 2=-180(LC 5),
10=-144(LC 6), 11=-218(LC 7), 9=-113(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 8 except 2=311(LC 6), 10=339(LC
11), 11=280(LC 1), 9=316(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-446/292, 3-4=-323/286, 4-5=-154/264, 6-7=-129/289, 7-8=-123/264
WEBS 4-10=-255/224, 3-11=-208/257, 6-9=-307/178
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-2-10 to 2-11-0, Interior(1) 2-11-0 to 10-3-8, Exterior(2) 10-3-8 to 13-3-8 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 164 lb uplift at joint 8, 180 lb uplift at
joint 2, 144 lb uplift at joint 10, 218 lb uplift at joint 11 and 113 lb uplift at joint 9.
6) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
PB1A
Truss Type
Piggyback
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547032
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:19 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-beUwewkWj9qzAd1fdgk?xAyOnL?q5ao7nNNGLfzRSaQ
Scale = 1:53.5
1
2
3
4 5
6
10 9 8 7
11
12
13
14
4x5 4x5
3x4
3x4
3x4
2x4
2x4
2x4 2x4
13-10-0
13-10-0
8-11-10
8-11-10
13-10-0
4-10-6
0-5-38-11-100-1-86-7-80-1-88-10-212.00 12
Plate Offsets (X,Y)-- [2:0-1-9,0-1-8], [4:0-3-4,0-1-12], [5:0-3-4,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-S
0.34
0.18
0.14
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.01
0.00
(loc)
1
1
7
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 67 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF No.2 *Except*
3-10: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 4-5.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 8-9.
WEBS 1 Row at midpt 4-9, 5-8
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 13-3-5.
(lb) - Max Horz 2=357(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 8 except 7=-114(LC 8), 2=-109(LC 5),
10=-266(LC 7), 9=-144(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 7, 2, 9, 8 except 10=408(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-351/242
WEBS 3-10=-293/304
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-2-10 to 3-2-10, Interior(1) 3-2-10 to 8-11-10, Exterior(2) 8-11-10 to 11-7-6 zone; cantilever left and right exposed ;
end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8 except (jt=lb)
7=114, 2=109, 10=266, 9=144.
7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
PB1B
Truss Type
Piggyback
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547033
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:20 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-3q2IrGl8UTyqoncrBNFEUOVa6lLmq?oG016pt5zRSaP
Scale = 1:41.4
1
2
3
4 5 6
10 9 8 7
11
12
13 14
4x5 3x4
3x4
3x4
2x4 2x4
2x4
2x4
2x4
13-10-0
13-10-0
6-11-10
6-11-10
13-7-6
6-7-12
13-10-0
0-2-10
0-5-36-11-100-1-86-6-100-1-86-10-212.00 12
Plate Offsets (X,Y)-- [2:0-2-6,0-1-8], [4:0-3-4,0-1-12], [6:0-2-0,0-0-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-S
0.31
0.14
0.22
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
1
1
7
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 58 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-6.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 13-3-5.
(lb) - Max Horz 2=256(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 7, 2 except 9=-112(LC 6),
10=-221(LC 7), 8=-104(LC 5)
Max Grav All reactions 250 lb or less at joint(s) 7, 2 except 9=303(LC 1), 10=298(LC
1), 8=313(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-405/155
WEBS 3-10=-224/260
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-2-10 to 3-1-6, Interior(1) 3-1-6 to 6-11-10, Exterior(2) 6-11-10 to 11-1-6 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 2 except (jt=lb)
9=112, 10=221, 8=104.
6) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
PB2
Truss Type
Piggyback
Qty
8
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547034
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:20 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-3q2IrGl8UTyqoncrBNFEUOVUIlMDq1qG016pt5zRSaP
Scale = 1:41.5
1
2
3
4
6 5
7
2x4
2x4
2x4
2x4
2x4
6-11-8
6-11-80-5-36-11-80-1-86-10-00-1-812.00 12
Plate Offsets (X,Y)-- [2:0-2-6,0-1-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.68
0.11
0.09
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
1
1
5
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 29 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)5=104/6-4-13, 2=105/6-4-13, 6=311/6-4-13
Max Horz 2=247(LC 6)
Max Uplift 5=-77(LC 6), 2=-70(LC 5), 6=-216(LC 7)
Max Grav 5=117(LC 5), 2=172(LC 6), 6=311(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-432/152
WEBS 3-6=-233/283
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-2-10 to 3-5-12, Interior(1) 3-5-12 to 6-9-12 zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2 except (jt=lb)
6=216.
5) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
PB3
Truss Type
Piggyback
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547035
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:21 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-X0cg2cmmFn4hPxB2k5mT0b1m49iaZUcPFhsMPYzRSaO
Scale = 1:36.3
1
2
3
4 5 6
7
8
12 11 10 9
13 14 15
3x6 3x6
3x4
2x4 3x4
2x4
2x4
2x4
2x4
2x4
2x4
13-10-0
13-10-0
4-11-10
4-11-10
12-5-10
7-6-0
13-10-0
1-4-6
0-5-34-11-106-4-00-1-86-2-80-1-84-10-212.00 12
Plate Offsets (X,Y)-- [2:0-2-6,0-1-8], [4:0-1-11,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-S
0.23
0.10
0.12
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
1
1
9
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 53 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-7.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 13-3-5.
(lb) - Max Horz 2=223(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 9, 2, 11 except 12=-173(LC 7),
10=-127(LC 5)
Max Grav All reactions 250 lb or less at joint(s) 9, 2 except 11=337(LC 1),
12=278(LC 1), 10=289(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-375/145
WEBS 5-11=-253/195, 3-12=-206/294
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-2-10 to 2-11-0, Interior(1) 2-11-0 to 4-11-10, Exterior(2) 4-11-10 to 9-2-9, Interior(1) 12-5-10 to 13-8-4 zone;
cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 2, 11 except
(jt=lb) 12=173, 10=127.
6) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
PB4
Truss Type
Piggyback
Qty
9
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547036
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:21 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-X0cg2cmmFn4hPxB2k5mT0b1oV9jMZVAPFhsMPYzRSaO
Scale = 1:18.2
1 2
3
4 5
6
4x5
2x4 2x4 2x4
5-4-0
5-4-0
2-8-0
2-8-0
5-4-0
2-8-0
0-5-32-8-00-1-80-5-30-1-812.00 12
Plate Offsets (X,Y)-- [2:0-2-6,0-1-0], [4:0-2-6,0-1-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.07
0.05
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
5
5
4
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 15 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-4-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)2=125/4-2-10, 4=125/4-2-10, 6=128/4-2-10
Max Horz 2=-66(LC 5)
Max Uplift 2=-55(LC 7), 4=-55(LC 8)
Max Grav 2=125(LC 1), 4=125(LC 1), 6=131(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) automatic zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4.
6) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
PB5
Truss Type
Piggyback
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547037
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:21 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-X0cg2cmmFn4hPxB2k5mT0b1n99iSZVxPFhsMPYzRSaO
Scale = 1:24.5
1
2
3
45
6
7 8
4x5
2x4 2x4 2x4
7-4-0
7-4-0
3-8-0
3-8-0
7-4-0
3-8-0
0-5-33-8-00-1-80-5-30-1-812.00 12
Plate Offsets (X,Y)-- [2:0-2-6,0-1-0], [4:0-2-6,0-1-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.16
0.11
0.03
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.01
0.00
(loc)
5
5
4
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 22 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)2=174/6-2-10, 4=174/6-2-10, 6=191/6-2-10
Max Horz 2=-95(LC 5)
Max Uplift 2=-71(LC 7), 4=-73(LC 8)
Max Grav 2=174(LC 1), 4=174(LC 1), 6=193(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-2-10 to 3-2-10, Interior(1) 3-2-10 to 3-8-0, Exterior(2) 3-8-0 to 6-9-5 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4.
6) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
PB6
Truss Type
Piggyback
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547038
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:22 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-?DA2GxnP04CY14mEIoHiZpaypY1xIymZULbwy_zRSaN
Scale = 1:29.6
1
2
3 4 5 6 7
13 12 11 10 9 8
14 15
4x5
3x4
3x6
17-4-0
17-4-0
2-0-0
2-0-0
17-4-0
15-4-0
0-5-31-10-82-0-00-1-81-10-80-1-812.00 12
Plate Offsets (X,Y)-- [2:0-2-6,0-1-8], [3:0-3-4,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-S
0.17
0.09
0.06
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
0.00
(loc)
1
1
8
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 47 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-7.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 16-9-5.
(lb) - Max Horz 2=66(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 8, 2, 13, 11, 9 except 12=-102(LC 5)
Max Grav All reactions 250 lb or less at joint(s) 8, 2, 13 except 12=347(LC 1),
11=317(LC 1), 9=306(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 4-12=-265/151
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-2-10 to 6-1-12, Interior(1) 6-1-12 to 17-2-4 zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) All plates are 2x4 MT20 unless otherwise indicated.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 2, 13, 11, 9
except (jt=lb) 12=102.
7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
PB7
Truss Type
Piggyback
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547039
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:22 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-?DA2GxnP04CY14mEIoHiZpauuY0TIy?ZULbwy_zRSaN
Scale = 1:13.8
1 2
34
6 5
7 8
9
2x4
2x4
4x5
2x4 2x4
6-11-10
6-11-10
4-11-10
4-11-10
6-11-10
2-0-0
1-10-82-0-00-1-80-5-30-1-81-10-812.00 12
Plate Offsets (X,Y)-- [2:0-3-8,0-2-0], [3:0-2-6,0-1-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.42
0.19
0.04
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
3
3
3
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 19 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 1-2.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)6=182/6-4-15, 3=72/6-4-15, 5=267/6-4-15
Max Horz 6=-66(LC 5)
Max Uplift 6=-60(LC 6), 3=-36(LC 8), 5=-37(LC 5)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 4-11-10, Exterior(2) 4-11-10 to 6-9-0 zone; cantilever left and right exposed ;
end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 3, 5.
6) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
Q1
Truss Type
Roof Special
Qty
4
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547003
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:23 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-TPkQTHn1nOKPfELQsWox6064DyJh1KEii_LTUQzRSaM
Scale = 1:58.2
1 2
3
4
5
6
7
8
9
11 1020
21 22
23
4x6
5x6
3x4
5x6
5x6
3x4
2x4
5x6
2x4
6-10-0
6-10-0
10-10-0
4-0-0
17-8-0
6-10-0
-0-11-0
0-11-0
6-10-0
6-10-0
8-10-0
2-0-0
10-10-0
2-0-0
17-8-0
6-10-0
18-7-0
0-11-0
0-7-109-5-100-7-103-3-412.00 12
6.00 12
Plate Offsets (X,Y)-- [2:0-1-11,Edge], [8:0-1-11,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.38
0.38
0.36
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.12
-0.18
0.10
(loc)
10-18
11-14
8
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 80 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
SLIDER Left 2x4 SPF Stud 2-0-0, Right 2x4 SPF Stud 2-0-0
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-11-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)2=762/0-3-8, 8=762/0-3-8
Max Horz 2=-265(LC 5)
Max Uplift 2=-115(LC 7), 8=-115(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-1260/88, 4-5=-1225/336, 5-6=-1225/283, 6-8=-1260/61
BOT CHORD 2-11=-166/938, 10-11=-25/528, 8-10=0/938
WEBS 5-10=-237/847, 6-10=-305/350, 5-11=-313/847, 4-11=-305/339
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 8-10-0, Exterior(2) 8-10-0 to 11-10-0 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=115, 8=115.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
RB1
Truss Type
GABLE
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547041
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:24 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-xbIphdofYiSGGOwdQDKAeEfI8MjRmpbsxe410tzRSaL
Scale = 1:57.8
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
30
29
28
27
26
25 24 23 22 21
20 19
18
17
16
3x6
4x5
3x6 3x6 3x6
6-10-0
6-10-0
10-10-0
4-0-0
17-8-0
6-10-0
-0-11-0
0-11-0
8-10-0
8-10-0
17-8-0
8-10-0
18-7-0
0-11-0
0-7-109-5-100-7-103-3-412.00 12
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-R
0.18
0.09
0.23
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.01
0.01
(loc)
15
15
16
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 93 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 17-8-0.
(lb) - Max Horz 30=283(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 16, 25, 21, 24, 26, 27, 28, 22, 20, 19, 18 except 30=-224(LC 5),
29=-145(LC 7), 17=-138(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 30, 16, 25, 21, 24, 26, 27, 28, 29, 22, 20, 19, 18, 17 except
23=324(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 7-8=-35/278, 8-9=-35/278
WEBS 8-23=-331/0
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Corner(3) -0-11-0 to 2-2-0, Exterior(2) 2-2-0 to 8-10-0, Corner(3) 8-10-0 to 11-10-0 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 2x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
7) Gable studs spaced at 1-4-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 25, 21, 24, 26,
27, 28, 22, 20, 19, 18 except (jt=lb) 30=224, 29=145, 17=138.
10) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 25, 21, 23, 24, 26, 27, 28, 29, 22, 20, 19,
18, 17.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
SG1
Truss Type
Roof Special Girder
Qty
1
Ply
2
17010206 Drake Residence
Job Reference (optional)
I29547042
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:25 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-QosBuzpHI?a7uYVpzxrPBRCSVm0WVFc?AIqaYJzRSaK
Scale: 3/8"=1’
1 2 3 4 5 6
12
11 10
9 8 7
13 14
15 16 17 18
19 20 21
2x4
3x6 3x6 2x4
4x5
2x4
2x4
5x10
5x8
3x4
2x4
3x10
NAILED NAILED
NAILED
NAILED
NAILED
NAILED
NAILED
NAILED
5-1-4
5-1-4
9-11-0
4-9-12
13-7-12
3-8-12
17-8-0
4-0-4
5-1-4
5-1-4
9-11-0
4-9-12
13-7-12
3-8-12
17-8-0
4-0-4
4-7-103-7-101-0-04-7-10Plate Offsets (X,Y)-- [9:0-2-12,0-2-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.14
0.29
0.31
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.03
-0.06
0.01
(loc)
10
10-11
7
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 200 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2 *Except*
3-10: 2x4 SPF Stud
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD 2-0-0 oc purlins (6-0-0 max.): 1-6, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)12=1196/0-3-8, 7=1203/Mechanical
Max Horz 12=141(LC 4)
Max Uplift 12=-518(LC 3), 7=-536(LC 4)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-12=-1065/476, 1-2=-1107/499, 2-3=-1633/726, 3-5=-1644/731
BOT CHORD 9-10=-128/256, 8-9=-572/1199, 7-8=-572/1199
WEBS 1-11=-643/1434, 2-11=-689/314, 9-11=-477/947, 2-9=-288/642, 5-9=-275/581,
5-8=-167/372, 5-7=-1543/701
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
12=518, 7=536.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
9) "NAILED" indicates 3-10d (0.148"x3") or 3-12d (0.148"x3.25") toe-nails per NDS guidlines.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-6=-60, 10-12=-20, 7-9=-20
Concentrated Loads (lb)
Vert: 10=-128(F) 15=-128(F) 16=-128(F) 17=-128(F) 18=-128(F) 19=-124(F) 20=-124(F) 21=-124(F)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
T1
Truss Type
Piggyback Base
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547007
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:25 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-QosBuzpHI?a7uYVpzxrPBRCMwm_IVEh?AIqaYJzRSaK
Scale = 1:65.4
1 2
3
4
5
9
78 6
14 15 16
17
18
19
3x4
3x10 4x5
5x8
3x4 2x4
5x6 5x16
3x6
6-9-8
6-9-8
10-9-8
4-0-0
17-7-8
6-10-0
6-11-10
6-11-10
10-9-8
3-9-14
17-7-8
6-10-0
11-5-00-7-100-1-83-3-48-0-412.00 12
6.00 12
Plate Offsets (X,Y)-- [2:0-3-4,0-1-12], [5:0-1-4,0-2-7], [7:0-9-12,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.56
0.43
0.37
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.14
-0.18
0.08
(loc)
6-12
6-12
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 99 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
3-7,3-6: 2x4 SPF Stud
SLIDER Right 2x4 SPF Stud 2-0-0
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-10-12 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 1-2.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 1-9
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)9=699/0-3-0, 5=699/0-3-8
Max Horz 9=-416(LC 5)
Max Uplift 9=-212(LC 5), 5=-49(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 8-9=-640/122, 1-8=-635/128, 1-2=-370/156, 2-3=-609/182, 3-5=-1244/117
BOT CHORD 7-9=-339/665, 6-7=-22/781, 5-6=-29/925
WEBS 1-7=-53/560, 2-7=-21/257, 3-7=-574/183, 3-6=0/514
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 6-11-10, Exterior(2) 6-11-10 to 9-11-10 zone; cantilever left and right exposed ;
end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5 except (jt=lb)
9=212.
6) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 9.
7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
T2
Truss Type
Roof Special
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547044
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:26 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-u_PZ6Jqv3JizWi3?XeMejfkXgAKXEhx9PyZ75lzRSaJ
Scale = 1:65.4
1 2
3
4
5
9
78 6
14 15 16
17
18
19
3x4
3x10 4x5
5x8
3x4 2x4
5x6 5x16
3x6
6-9-8
6-9-8
10-9-8
4-0-0
17-7-8
6-10-0
6-11-10
6-11-10
10-9-8
3-9-14
17-7-8
6-10-0
11-5-00-7-100-1-83-3-48-0-412.00 12
6.00 12
Plate Offsets (X,Y)-- [2:0-3-4,0-1-12], [5:0-1-4,0-2-7], [7:0-9-12,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.56
0.43
0.37
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.14
-0.18
0.08
(loc)
6-12
6-12
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 99 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
3-7,3-6: 2x4 SPF Stud
SLIDER Right 2x4 SPF Stud 2-0-0
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-10-12 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 1-2.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 1-9
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)9=699/0-3-0, 5=699/0-3-8
Max Horz 9=-416(LC 5)
Max Uplift 9=-212(LC 5), 5=-49(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 8-9=-640/122, 1-8=-635/128, 1-2=-370/156, 2-3=-609/182, 3-5=-1244/117
BOT CHORD 7-9=-339/665, 6-7=-22/781, 5-6=-29/925
WEBS 1-7=-53/560, 2-7=-21/257, 3-7=-574/183, 3-6=0/514
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 6-11-10, Exterior(2) 6-11-10 to 9-11-10 zone; cantilever left and right exposed ;
end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5 except (jt=lb)
9=212.
6) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 9.
7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
U1
Truss Type
Roof Special
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547008
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:26 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-u_PZ6Jqv3JizWi3?XeMejfkWLAKzEiB9PyZ75lzRSaJ
Scale = 1:53.9
1 2 3
4
5
6
10
9 8 7
15 16
17
18
19
3x6
5x6 4x5
5x8
3x4
5x8 5x6
3x4
5x8
3x6
6-9-8
6-9-8
8-11-10
2-2-2
10-9-8
1-9-14
17-7-8
6-10-0
6-9-8
6-9-8
8-11-10
2-2-2
10-9-8
1-9-14
17-7-8
6-10-0
9-5-00-7-100-1-83-3-46-0-412.00 12
6.00 12
Plate Offsets (X,Y)-- [3:0-3-4,0-1-12], [6:0-1-4,0-2-7]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.58
0.41
0.29
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.13
-0.22
0.07
(loc)
7-13
9-10
6
l/defl
>999
>933
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 97 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud *Except*
1-10,1-9: 2x4 SPF No.2
SLIDER Right 2x4 SPF Stud 2-0-0
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-10-14 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 1-3.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 1-10
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)10=699/0-3-0, 6=699/0-3-8
Max Horz 10=-339(LC 5)
Max Uplift 10=-187(LC 5), 6=-57(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-10=-639/143, 1-2=-546/148, 2-3=-529/135, 3-4=-858/245, 4-6=-1248/125
BOT CHORD 9-10=-181/445, 8-9=-175/555, 7-8=-43/785, 6-7=-51/929
WEBS 1-9=-43/707, 2-9=-344/274, 3-8=-225/668, 4-8=-659/271, 4-7=0/515
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 8-11-10, Exterior(2) 8-11-10 to 11-11-10 zone; cantilever left and right exposed
; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6 except (jt=lb)
10=187.
6) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 10.
7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V1
Truss Type
VALLEY
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547046
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:27 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-MAzxJfqXqdrq7seC5MttGsHnZZk4z9XIdcJhdCzRSaI
Scale = 1:69.1
1
2
3
4 5
8 7 6
9
10
3x4
4x5
2x4
3x6 2x4
2x4
2x4
2x4
0-0-4
0-0-4
11-11-0
11-10-12
11-5-0
11-5-0
11-11-0
0-6-0
0-0-411-5-010-11-012.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.23
0.16
0.28
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
6
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 68 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF Stud *Except*
4-6: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-6, 4-6
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 11-10-12.
(lb) - Max Horz 1=360(LC 7)
Max Uplift All uplift 100 lb or less at joint(s) 1, 6 except 7=-229(LC 8), 8=-210(LC
7)
Max Grav All reactions 250 lb or less at joint(s) 6 except 1=316(LC 8), 7=367(LC 1),
8=302(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-472/79, 2-3=-324/88
WEBS 3-7=-273/286, 2-8=-227/255
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-4-4 to 3-5-0, Interior(1) 3-5-0 to 11-5-0, Exterior(2) 11-5-0 to 11-9-4 zone; cantilever left and right exposed ; end
vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 6 except (jt=lb)
7=229, 8=210.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V2
Truss Type
Valley
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547047
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:31 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-ExDS90u2urLGcTyzKBypQiSOGB5yv_7uYEHumzzRSaE
Scale = 1:65.8
1
2
3
4 5
8 7 6
9
10
11
12
3x4
4x5
2x4
3x6 2x4
2x4
2x4
2x4
11-4-5
11-4-5
10-10-5
10-10-5
11-4-5
0-6-0
0-0-410-10-510-4-512.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.57
0.16
0.24
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
6
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 64 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF 2100F 1.8E
OTHERS 2x4 SPF Stud *Except*
4-6: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-6, 4-6
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 11-4-1.
(lb) - Max Horz 1=468(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) except 1=-135(LC 5), 6=-133(LC 6),
7=-233(LC 8), 8=-199(LC 7)
Max Grav All reactions 250 lb or less at joint(s) 6 except 1=343(LC 6), 7=372(LC 1),
8=277(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-613/238, 2-3=-464/226, 4-5=-149/270
WEBS 4-6=-291/307, 3-7=-277/290
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-4-4 to 3-4-4, Interior(1) 3-4-4 to 10-10-5, Exterior(2) 10-10-5 to 11-2-9 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 135 lb uplift at joint 1, 133 lb uplift at
joint 6, 233 lb uplift at joint 7 and 199 lb uplift at joint 8.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V3
Truss Type
Valley
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547048
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:33 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-BKKCaivIQTb_sn6LRc_HW7Xj3_mkNvBB0Ym?qrzRSaC
Scale = 1:55.3
1
2
3 4
6 5
7
8
2x4
4x5
2x4
3x6 2x4
2x4
9-4-5
9-4-5
8-10-5
8-10-5
9-4-5
0-6-0
0-0-48-10-58-4-512.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.61
0.21
0.14
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 49 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2 *Except*
2-6: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 4-5, 3-5
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=141/9-4-1, 5=136/9-4-1, 6=428/9-4-1
Max Horz 1=378(LC 6)
Max Uplift 1=-77(LC 5), 5=-110(LC 6), 6=-254(LC 8)
Max Grav 1=245(LC 6), 5=146(LC 5), 6=428(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-469/199
WEBS 3-5=-233/266, 2-6=-319/319
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-4-4 to 3-4-4, Interior(1) 3-4-4 to 8-10-5, Exterior(2) 8-10-5 to 9-2-9 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 77 lb uplift at joint 1, 110 lb uplift at joint
5 and 254 lb uplift at joint 6.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V4
Truss Type
Valley
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547049
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:33 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-BKKCaivIQTb_sn6LRc_HW7XgT_o6NvmB0Ym?qrzRSaC
Scale = 1:45.8
1
2
3 4
7 6 5
8
9
10
2x4
4x5 2x4
2x4 2x4 2x4
2x4
9-11-15
9-11-15
7-3-13
7-3-13
9-11-15
2-8-2
0-0-47-3-1312.00 12
Plate Offsets (X,Y)-- [3:0-3-8,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.78
0.12
0.17
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 44 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins: 3-4.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 9-11-11.
(lb) - Max Horz 1=270(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 6 except 7=-235(LC 7)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 6 except 7=344(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-440/163
WEBS 2-7=-263/284
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-4-4 to 3-5-9, Interior(1) 3-5-9 to 7-3-13, Exterior(2) 7-3-13 to 9-10-3 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 6 except
(jt=lb) 7=235.
6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V5
Truss Type
Valley
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547050
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:34 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-fWuan2wwBmjrTwhY?KVW2L4rkO7m6N?KECVYNIzRSaB
Scale = 1:45.9
1
2
3 4
6 5
7
8
9
2x4
4x5 2x4
3x6
2x4
2x4
7-11-15
7-11-15
7-3-13
7-3-13
7-11-15
0-8-2
0-0-47-3-1312.00 12
Plate Offsets (X,Y)-- [3:0-3-8,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.81
0.15
0.11
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 40 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins: 3-4.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=88/7-11-11, 5=152/7-11-11, 6=356/7-11-11
Max Horz 1=270(LC 6)
Max Uplift 1=-72(LC 5), 5=-101(LC 6), 6=-228(LC 7)
Max Grav 1=186(LC 6), 5=152(LC 1), 6=356(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-450/158
WEBS 2-6=-263/291
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-4-4 to 3-5-9, Interior(1) 3-5-9 to 7-3-13, Exterior(2) 7-3-13 to 7-10-3 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb)
5=101, 6=228.
6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V6
Truss Type
Valley
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547051
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:34 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-fWuan2wwBmjrTwhY?KVW2L4tHO7w6MDKECVYNIzRSaB
Scale = 1:45.8
1
2
3 4
6 5
7
8
9
10
2x4
4x5
2x4
3x6 2x4
2x4
7-4-5
7-4-5
6-10-5
6-10-5
7-4-5
0-6-0
0-0-46-10-56-4-512.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.65
0.14
0.16
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 36 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=53/7-4-1, 5=150/7-4-1, 6=342/7-4-1
Max Horz 1=288(LC 6)
Max Uplift 1=-80(LC 5), 5=-96(LC 6), 6=-225(LC 7)
Max Grav 1=204(LC 6), 5=150(LC 1), 6=342(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-401/153
WEBS 2-6=-254/278
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-4-4 to 3-4-4, Interior(1) 3-4-4 to 6-10-5, Exterior(2) 6-10-5 to 7-2-9 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb)
6=225.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V7
Truss Type
Valley
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547052
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:35 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-7jSz?OxYy4ri54FkZ10lbYc2?oTUrqYTTsF6vkzRSaA
Scale = 1:40.9
1
2
3
5 4
6
7
8
2x4
2x4
2x4 2x4
2x4
6-8-11
6-8-11
0-0-46-8-1112.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.65
0.12
0.09
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 27 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=47/6-8-7, 4=125/6-8-7, 5=326/6-8-7
Max Horz 1=239(LC 6)
Max Uplift 1=-79(LC 5), 4=-82(LC 6), 5=-220(LC 7)
Max Grav 1=176(LC 6), 4=125(LC 1), 5=326(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-440/149
WEBS 2-5=-244/283
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-4-4 to 3-4-4, Interior(1) 3-4-4 to 6-6-15 zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb)
5=220.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V8
Truss Type
GABLE
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547053
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:35 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-7jSz?OxYy4ri54FkZ10lbYc7GoRLroRTTsF6vkzRSaA
Scale = 1:44.4
1
2
3
4
5
6
7
8
9
16 15 14 13 12 11 10
17
18 19
20
3x4
3x4
4x5
3x4
3x4
8-4-0
8-4-0
-0-11-0
0-11-0
4-2-0
4-2-0
8-4-0
4-2-0
9-3-0
0-11-0
2-5-136-7-132-5-1312.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-R
0.37
0.20
0.22
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.01
0.00
(loc)
9
9
10
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 57 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 8-4-0.
(lb) - Max Horz 16=-222(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) 14, 12 except 16=-245(LC 5), 10=-241(LC 6), 15=-263(LC 6),
11=-259(LC 5)
Max Grav All reactions 250 lb or less at joint(s) 16, 10, 14, 12 except 13=286(LC 8), 15=265(LC 5), 11=261(LC
6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 5-13=-277/0
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 4-2-0, Exterior(2) 4-2-0 to 7-2-0 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) All plates are 2x4 MT20 unless otherwise indicated.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 12 except
(jt=lb) 16=245, 10=241, 15=263, 11=259.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V9
Truss Type
Valley
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547054
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:36 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-bv0LCkxBjOzZjEqw7kX_7m9L2Cp9aHPdiW_fRAzRSa9
Scale = 1:40.7
1
2
3
4
5
8 7 6
9
10 11
12
3x4
4x5
3x4
2x4 2x4
2x4
2x4
2x4
0-0-4
0-0-4
13-3-0
13-2-12
6-7-8
6-7-8
13-3-0
6-7-8
0-0-46-7-80-0-412.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-S
0.18
0.10
0.11
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 47 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 13-2-8.
(lb) - Max Horz 1=-185(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-213(LC 7), 6=-213(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=305(LC 11), 6=305(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-8=-236/254, 4-6=-236/253
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-4-4 to 3-4-4, Interior(1) 3-4-4 to 6-7-8, Exterior(2) 6-7-8 to 9-7-8 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb)
8=213, 6=213.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V10
Truss Type
Valley
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547055
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:27 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-MAzxJfqXqdrq7seC5MttGsHjCZlezCYIdcJhdCzRSaI
Scale = 1:36.3
1
2
3
5 4
6
7
2x4
2x4
2x4
2x4
2x4
5-11-15
5-11-15
0-0-45-11-1512.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.51
0.12
0.09
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 24 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-11-15 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=-2/5-11-11, 4=125/5-11-11, 5=317/5-11-11
Max Horz 1=211(LC 6)
Max Uplift 1=-86(LC 5), 4=-76(LC 6), 5=-215(LC 7)
Max Grav 1=167(LC 6), 4=125(LC 1), 5=317(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-427/135
WEBS 2-5=-237/285
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-4-4 to 3-4-4, Interior(1) 3-4-4 to 5-10-3 zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb)
5=215.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V11
Truss Type
Valley
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547056
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:27 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-MAzxJfqXqdrq7seC5MttGsHlmZjpzCmIdcJhdCzRSaI
Scale = 1:31.2
1
2 3
4
5
6
2x4
4x5
2x4
3x6
5-4-5
5-4-5
4-10-5
4-10-5
5-4-5
0-6-0
0-0-44-10-54-4-512.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.34
0.24
0.07
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 24 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-4-5 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=187/5-4-1, 4=198/5-4-1
Max Horz 1=198(LC 6)
Max Uplift 4=-93(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) automatic zone and C-C
Exterior(2) 0-4-4 to 3-4-4, Interior(1) 3-4-4 to 4-10-5, Exterior(2) 4-10-5 to 5-2-9 zone; cantilever left and right exposed ; end vertical
left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V12
Truss Type
Valley
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547057
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:28 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-qNXJW?r9bwzhl?DOf3O6p4qxzz3ligARsG2E9ezRSaH
Scale = 1:26.6
1
2
3
4
2x4
2x4
2x4
4-8-11
4-8-11
0-0-44-8-1112.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.31
0.19
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 17 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-8-11 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=169/4-8-7, 3=169/4-8-7
Max Horz 1=162(LC 6)
Max Uplift 1=-1(LC 5), 3=-77(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-4-4 to 3-4-4, Interior(1) 3-4-4 to 4-6-15 zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V13
Truss Type
Valley
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547058
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:28 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-qNXJW?r9bwzhl?DOf3O6p4qxuz3Xif7RsG2E9ezRSaH
Scale = 1:31.5
1
2
3
4
5
6 7
8
2x4
4x5
2x4
2x4
0-0-4
0-0-4
9-4-9
9-4-5
4-8-5
4-8-5
9-4-9
4-8-5
0-0-44-8-50-0-412.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.32
0.21
0.07
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 29 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=212/9-4-1, 3=212/9-4-1, 4=270/9-4-1
Max Horz 1=-128(LC 5)
Max Uplift 1=-63(LC 7), 3=-68(LC 8)
Max Grav 1=212(LC 1), 3=212(LC 1), 4=271(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-4-4 to 3-4-4, Interior(1) 3-4-4 to 4-8-5, Exterior(2) 4-8-5 to 7-8-5 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V14
Truss Type
VALLEY
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547059
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:29 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-IZ5hkLsoME5YN9oaCmvLLHM6TNP0R7Tb5wonh4zRSaG
Scale: 3/8"=1’
1
2
3
4
5
6
7
8 9
10
4x5
2x4 2x4
2x4
8-4-0
8-4-0
-0-11-0
0-11-0
4-2-0
4-2-0
8-4-0
4-2-0
9-3-0
0-11-0
0-5-134-7-130-5-1312.00 12
Plate Offsets (X,Y)-- [2:0-2-11,0-1-0], [4:0-2-11,0-1-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.27
0.19
0.06
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.03
0.05
0.00
(loc)
5
5
4
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 31 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)2=263/8-4-0, 4=263/8-4-0, 6=252/8-4-0
Max Horz 2=-131(LC 5)
Max Uplift 2=-113(LC 7), 4=-121(LC 8)
Max Grav 2=263(LC 1), 4=263(LC 1), 6=257(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 4-2-0, Exterior(2) 4-2-0 to 7-2-0 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=113, 4=121.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V15
Truss Type
Valley
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547060
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:29 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-IZ5hkLsoME5YN9oaCmvLLHM7CNPxR7Pb5wonh4zRSaG
Scale = 1:23.0
1
2
3
4
2x4
2x4
2x4
3-11-15
3-11-15
0-0-43-11-1512.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.22
0.13
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 14 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-11-15 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=140/3-11-11, 3=140/3-11-11
Max Horz 1=134(LC 6)
Max Uplift 1=-1(LC 5), 3=-64(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-4-4 to 3-4-4, Interior(1) 3-4-4 to 3-10-3 zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V16
Truss Type
Valley
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547061
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:29 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-IZ5hkLsoME5YN9oaCmvLLHM9zNQnR7qb5wonh4zRSaG
Scale = 1:17.3
1
2 3
4
2x4
4x5
2x4
3x6
3-4-5
3-4-5
2-10-5
2-10-5
3-4-5
0-6-0
0-0-42-10-52-4-512.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.11
0.08
0.04
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 14 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-4-5 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=107/3-4-1, 4=118/3-4-1
Max Horz 1=107(LC 6)
Max Uplift 1=-4(LC 7), 4=-47(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) automatic zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V17
Truss Type
Valley
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547062
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:30 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-mlf4xhtQ7YDP_JNmmUQauVvK2nnPAafkJaXLEWzRSaF
Scale = 1:16.6
1
2
3
2x4
2x4
2x4
2-8-11
2-8-11
0-0-42-8-1112.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.09
0.05
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 9 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-8-11 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=89/2-8-7, 3=89/2-8-7
Max Horz 1=85(LC 6)
Max Uplift 3=-41(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS
for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V18
Truss Type
Valley
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547063
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:30 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-mlf4xhtQ7YDP_JNmmUQauVvKxnnHAaKkJaXLEWzRSaF
Scale = 1:19.2
1
2
3
4
2x4
4x5
2x4 2x4
0-0-4
0-0-4
5-4-9
5-4-5
2-8-5
2-8-5
5-4-9
2-8-5
0-0-42-8-50-0-412.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.09
0.06
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 16 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-4-9 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=114/5-4-1, 3=114/5-4-1, 4=146/5-4-1
Max Horz 1=-69(LC 5)
Max Uplift 1=-41(LC 7), 3=-41(LC 7)
Max Grav 1=114(LC 1), 3=114(LC 1), 4=146(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) automatic zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V19
Truss Type
Valley
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547064
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:31 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-ExDS90u2urLGcTyzKBypQiSVjB7Yv1buYEHumzzRSaE
Scale = 1:18.9
1
2
3
4
2x4
4x5
2x4 2x4
0-0-4
0-0-4
5-3-9
5-3-5
2-7-13
2-7-13
5-3-9
2-7-13
0-0-42-7-130-0-412.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.09
0.06
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 16 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-3-9 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=112/5-3-1, 3=112/5-3-1, 4=143/5-3-1
Max Horz 1=-68(LC 5)
Max Uplift 1=-40(LC 7), 3=-40(LC 7)
Max Grav 1=112(LC 1), 3=112(LC 1), 4=143(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) automatic zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V20
Truss Type
Valley
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547065
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:32 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-i8nqMMugf9T7EdX9uvT2zw_hCaTKeU91nu0SIPzRSaD
Scale = 1:12.9
1
2
3
2x4
2x4
2x4
1-11-15
1-11-15
0-0-41-11-1512.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.04
0.02
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 6 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 1-11-15 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=60/1-11-11, 3=60/1-11-11
Max Horz 1=57(LC 6)
Max Uplift 3=-27(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS
for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 27 lb uplift at joint 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V21
Truss Type
Valley
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547066
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:32 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-i8nqMMugf9T7EdX9uvT2zw_h9aTEeUy1nu0SIPzRSaD
Scale = 1:12.7
1
2
3
4
2x4
4x5
2x4 2x4
3-11-5
3-11-5
3-11-9
0-0-4
1-11-13
1-11-13
3-11-9
1-11-13
0-0-41-11-130-0-412.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.05
0.03
0.01
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 11 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-11-9 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=80/3-11-1, 3=80/3-11-1, 4=102/3-11-1
Max Horz 1=48(LC 6)
Max Uplift 1=-29(LC 7), 3=-29(LC 7)
Max Grav 1=80(LC 1), 3=80(LC 1), 4=102(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) automatic zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 29 lb uplift at joint 1 and 29 lb uplift at
joint 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
V22
Truss Type
Valley
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547067
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:32 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-i8nqMMugf9T7EdX9uvT2zw_hmaTYeU91nu0SIPzRSaD
Scale = 1:7.4
1
2 3
4x6 2x4
0-0-3
0-0-3
1-6-14
1-6-10
0-9-7
0-9-7
1-6-14
0-9-7
0-0-40-11-00-0-414.00 12
Plate Offsets (X,Y)-- [1:0-1-8,0-1-8], [1:0-1-11,0-1-3], [2:0-1-14,0-1-14]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-P
0.01
0.01
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 4 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 1-6-14 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=37/1-6-7, 3=37/1-6-7
Max Horz 1=-17(LC 5)
Max Uplift 1=-7(LC 7), 3=-7(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) automatic zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 7 lb uplift at joint 1 and 7 lb uplift at joint
3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
VB1
Truss Type
GABLE
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547068
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:37 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-35ajP4ypUh5QKOP7gS2DgziLJb4YJdrmwAkDzczRSa8
Scale = 1:57.6
1
2
3
4
5
6
9
8 7
42 43 44
45
3x4
3x10
5x12
4x5
5x8
3x4
6x8 5x10
6-9-8
6-9-8
10-9-8
4-0-0
17-7-8
6-10-0
6-7-6
6-7-6
8-9-8
2-2-2
10-9-8
2-0-0
17-7-8
6-10-0
7-5-09-7-20-7-100-1-83-3-44-0-412.00 12
6.00 12
Plate Offsets (X,Y)-- [6:0-1-4,0-2-7], [7:0-3-0,0-2-8], [8:0-4-0,0-1-11], [13:0-2-0,0-0-10]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.85
0.40
0.55
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.14
-0.25
0.09
(loc)
7-40
8-9
6
l/defl
>999
>851
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 138 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud *Except*
1-8: 2x4 SPF No.2
OTHERS 2x4 SPF Stud
SLIDER Right 2x4 SPF Stud 2-0-0
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-9-4 oc purlins,
except end verticals, and 2-0-0 oc purlins (5-7-6 max.): 1-2.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)9=699/0-3-0, 6=699/0-3-8
Max Horz 9=-371(LC 5)
Max Uplift 9=-181(LC 5), 6=-64(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-9=-640/85, 1-2=-817/124, 2-3=-634/126, 3-4=-1245/374, 4-6=-1244/114
BOT CHORD 8-9=-211/358, 7-8=-111/801, 6-7=0/924
WEBS 1-8=-0/919, 2-8=-338/224, 2-7=-538/130, 3-7=-378/1273, 4-7=-356/396
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 8-9-8, Exterior(2) 8-9-8 to 11-9-8 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Provide adequate drainage to prevent water ponding.
5) All plates are 2x4 MT20 unless otherwise indicated.
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6 except (jt=lb)
9=181.
10) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 9.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
W1
Truss Type
Common
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547069
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:37 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-35ajP4ypUh5QKOP7gS2DgziWqb3fJjlmwAkDzczRSa8
Scale = 1:53.8
1
2
3
4
5
6
7
8
15
16
17 18
19
20
3x10 5x8
4x5
2x4 2x4
3x10
8-4-0
8-4-0
16-8-0
8-4-0
-0-11-0
0-11-0
4-2-7
4-2-7
8-4-0
4-1-9
12-5-9
4-1-9
16-8-0
4-2-7
17-7-0
0-11-0
0-7-108-11-100-7-1012.00 12
Plate Offsets (X,Y)-- [2:0-0-7,0-0-7], [2:0-0-13,0-3-3], [2:0-3-8,Edge], [6:0-3-8,Edge], [6:0-0-13,0-3-3], [6:0-0-7,0-0-7], [8:0-4-0,0-3-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.18
0.46
0.17
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.07
-0.19
0.01
(loc)
8-11
8-11
2
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 74 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud *Except*
4-8: 2x4 SPF No.2
WEDGE
Left: 2x6 SPF No.2, Right: 2x6 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)2=722/0-3-8, 6=722/0-3-8
Max Horz 2=-250(LC 5)
Max Uplift 2=-113(LC 7), 6=-113(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-733/137, 3-4=-577/176, 4-5=-577/176, 5-6=-733/137
BOT CHORD 2-8=-98/473, 6-8=0/473
WEBS 4-8=-132/481
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 8-4-0, Exterior(2) 8-4-0 to 11-4-0 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=113, 6=113.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
W2
Truss Type
Roof Special
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547070
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:38 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-XI85dQzRF?DGyY_JE9aSCBEez?QB23ew9qTmW3zRSa7
Scale = 1:59.2
1 2
3
4
5
6
7
8 9
16 15
14
13
12
11 10
23
24 25
26
4x5
3x6 2x4
5x10 5x10
2x4 3x6
3x6
3x4
5x12
5x8
3x6
3x4
5x12
1-2-3
1-2-3
2-3-8
1-1-5
8-4-0
6-0-8
14-4-8
6-0-8
15-5-13
1-1-5
16-8-0
1-2-3
-0-11-0
0-11-0
1-2-3
1-2-3
2-3-8
1-1-5
8-4-0
6-0-8
14-4-8
6-0-8
15-5-13
1-1-5
16-8-0
1-2-3
17-7-0
0-11-0
0-7-108-11-100-7-101-0-012.00 12
Plate Offsets (X,Y)-- [2:0-0-7,0-0-7], [2:0-0-13,0-3-3], [8:0-0-7,0-0-7], [8:0-0-13,0-3-3]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.34
0.44
0.58
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.04
-0.13
0.08
(loc)
13-14
13-14
8
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 84 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
4-15,6-11: 2x4 SPF Stud
WEBS 2x4 SPF Stud *Except*
5-13: 2x4 SPF No.2
WEDGE
Left: 2x4 SPF Stud, Right: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-11-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)2=722/0-3-8, 8=722/0-3-8
Max Horz 2=-250(LC 5)
Max Uplift 2=-113(LC 7), 8=-113(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-713/87, 3-4=-1243/149, 4-5=-689/135, 5-6=-689/131, 6-7=-1243/84, 7-8=-713/87
BOT CHORD 2-16=-117/422, 4-14=-3/363, 13-14=-299/1062, 12-13=-116/1062, 6-12=0/363,
8-10=0/422
WEBS 3-16=-466/59, 14-16=-126/538, 3-14=-149/583, 5-13=-34/481, 4-13=-692/352,
6-13=-692/286, 7-10=-466/0, 10-12=0/538, 7-12=-85/583
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-12, Interior(1) 2-1-12 to 8-4-0, Exterior(2) 8-4-0 to 11-4-0 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=113, 8=113.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
XB1
Truss Type
GABLE
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547071
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:39 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-?UiTql_3?JL7aiZVot5hlOntZPoFndP3OUDJ2VzRSa6
Scale = 1:58.2
1 2
3
4
5
6
7
8
9
10
11
12
13
1415
27 26 25
24 23 22 21 20
19 17 16
34
35
36
37
38
39
183x6
4x5
3x6 5x6
4-5-8
4-5-8
8-4-0
3-10-8
12-9-8
4-5-8
16-8-0
3-10-8
-0-11-0
0-11-0
8-4-0
8-4-0
16-8-0
8-4-0
17-7-0
0-11-0
0-7-108-11-100-7-1012.00 12
Plate Offsets (X,Y)-- [2:0-0-7,0-0-7], [2:0-0-13,0-3-3], [14:0-0-7,0-0-7], [14:0-0-13,0-3-3], [17:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.10
0.26
0.10
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.01
-0.03
0.01
(loc)
20-21
20-21
14
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 110 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF Stud *Except*
7-23,9-21: 2x4 SPF No.2
WEDGE
Left: 2x4 SPF Stud, Right: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 4-5-8 except (jt=length) 14=4-2-0, 17=4-2-0, 16=4-2-0, 25=0-3-8,
25=0-3-8, 18=0-3-8, 14=4-2-0.
(lb) - Max Horz 2=-250(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) 2, 14, 26, 17 except 27=-138(LC 7),
16=-139(LC 8), 25=-153(LC 7), 18=-178(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 26, 27, 17, 16 except 2=325(LC 1),
14=325(LC 1), 25=306(LC 11), 25=290(LC 1), 18=355(LC 12), 2=325(LC 1),
14=325(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-295/53, 3-4=-261/37, 5-6=-288/14, 6-7=-258/55, 9-10=-254/53, 10-11=-294/11,
12-13=-257/28, 13-14=-281/39
BOT CHORD 2-27=-10/273, 26-27=-10/273, 25-26=-10/273, 24-25=-10/273, 23-24=-10/273,
22-23=-10/273, 21-22=-10/273, 20-21=-10/273, 19-20=-10/273, 18-19=-10/273,
17-18=-10/273, 16-17=-10/273, 14-16=-10/273
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 8-4-0, Exterior(2) 8-4-0 to 11-4-0 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 2x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 1-4-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 14, 26, 17, 2,
14 except (jt=lb) 27=138, 16=139, 25=153, 18=178.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
YG1
Truss Type
Roof Special Girder
Qty
1
Ply
3
17010206 Drake Residence
Job Reference (optional)
I29547072
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:40 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-TgGs25?hmcT_Br8hMacwIcKySp0hWxsCd8ytaxzRSa5
Scale = 1:62.5
1 2
3
4
5
6
7
8
9
17 16
15 14 13 12
11 10
24 25
26 27 28 29 30 31 32
33
4x6
5x8
5x6 3x6
4x5 5x8
3x6
4x6
4x6 5x10
12x16
5x8
2x4
6x8
2x4
6x8
HUS26 LUS26
LUS26
LUS26 LUS26
LUS26
LUS26
HUS26
1-3-3
1-3-3
2-3-8
1-0-5
5-3-12
3-0-4
11-4-4
6-0-8
14-4-8
3-0-4
15-4-13
1-0-5
16-8-0
1-3-3
1-0-0
1-0-0
2-3-8
1-3-8
5-3-12
3-0-4
8-4-0
3-0-4
11-4-4
3-0-4
14-4-8
3-0-4
15-4-13
1-0-5
16-8-0
1-3-3
0-7-108-11-100-7-101-0-012.00 12
Plate Offsets (X,Y)-- [1:0-1-10,Edge], [3:0-0-12,0-1-12], [8:0-3-4,0-4-8], [9:0-0-0,0-0-1], [10:0-3-8,0-2-8], [13:0-2-12,0-2-12], [14:0-1-12,0-2-12], [15:0-6-12,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.47
0.82
0.66
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.10
-0.24
0.16
(loc)
13-14
13-14
9
l/defl
>999
>846
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 328 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
1-16,9-11: 2x6 SPF No.2, 12-15: 2x6 SP 2400F 2.0E
WEBS 2x4 SPF Stud *Except*
5-14,5-13: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=4737/0-3-8, 9=5143/0-3-8
Max Horz 1=246(LC 4)
Max Uplift 1=-499(LC 5), 9=-543(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-5162/549, 2-3=-10987/1227, 3-4=-6255/695, 4-5=-6232/854, 5-6=-6239/833,
6-7=-6275/685, 7-8=-10461/1087, 8-9=-5528/595
BOT CHORD 1-17=-449/3351, 16-17=-108/900, 15-16=-134/1317, 3-15=-572/4693, 14-15=-982/7977,
13-14=-277/2686, 12-13=-767/7717, 11-12=-79/834, 7-12=-395/4092, 10-11=-94/895,
9-10=-361/3636
WEBS 2-17=-3643/448, 15-17=-508/3620, 2-15=-511/4470, 8-10=-4353/433, 10-12=-448/4591,
8-12=-396/4103, 5-14=-643/4581, 5-13=-630/4599, 7-13=-3570/481, 3-14=-3877/566
NOTES-
1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc, 2x4 - 1 row at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, Except member 8-10 2x4 - 2 rows staggered at 0-4-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=499, 9=543.
7) Use Simpson Strong-Tie HUS26 (14-10d Girder, 4-10d Truss, Single Ply Girder) or equivalent spaced at 14-0-0 oc max. starting at
1-8-12 from the left end to 15-8-12 to connect truss(es) to front face of bottom chord.
8) Use Simpson Strong-Tie LUS26 (4-SD9112 Girder, 4-SD9212 Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max.
starting at 3-8-12 from the left end to 13-8-12 to connect truss(es) to front face of bottom chord.
9) Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(S) Standard
Continued on page 2
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
Job
A
Truss
YG1
Truss Type
Roof Special Girder
Qty
1
Ply
3
17010206 Drake Residence
Job Reference (optional)
I29547072
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:40 2017 Page 2 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-TgGs25?hmcT_Br8hMacwIcKySp0hWxsCd8ytaxzRSa5
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-5=-60, 5-9=-60, 16-18=-20, 12-15=-20, 11-21=-20
Concentrated Loads (lb)
Vert: 26=-1068(F) 27=-1068(F) 28=-1068(F) 29=-1068(F) 30=-1068(F) 31=-1068(F) 32=-1068(F) 33=-1069(F)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
A
Truss
Z1
Truss Type
Half Hip
Qty
1
Ply
1
17010206 Drake Residence
Job Reference (optional)
I29547073
8.030 s Jan 23 2017 MiTek Industries, Inc. Wed Apr 12 12:48:40 2017 Page 1 Carter Lumber, Franklin, Indiana 46131
ID:avvaS?ho1n0h9CYf_5bWgmz4mYs-TgGs25?hmcT_Br8hMacwIcKwTp7xW?0Cd8ytaxzRSa5
Scale = 1:70.7
1 2
3 4
7 6 5
89
10
11 12
6x8 3x6
2x4 3x10
3x4
6x8
6-8-0
6-8-0
14-3-8
7-7-8
-0-11-0
0-11-0
6-8-0
6-8-0
14-3-8
7-7-8
5-11-412-7-412.00 12
Plate Offsets (X,Y)-- [2:0-3-8,Edge], [3:0-2-11,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
Matrix-MS
0.60
0.36
0.39
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.06
-0.16
-0.01
(loc)
5-6
5-6
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 105 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
4-5: 2x6 SPF No.2, 2-7: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4.
BOT CHORD Rigid ceiling directly applied or 7-2-6 oc bracing.
WEBS 1 Row at midpt 4-5, 3-5
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)7=623/0-3-8, 5=554/0-3-8
Max Horz 7=481(LC 6)
Max Uplift 7=-74(LC 5), 5=-294(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-387/186, 2-7=-566/221
BOT CHORD 6-7=-647/373, 5-6=-351/253
WEBS 3-5=-317/423, 2-6=-162/392
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=70ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and
C-C Exterior(2) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 6-8-0, Exterior(2) 6-8-0 to 10-10-15 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7 except (jt=lb)
5=294.
5) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
April 12,2017
edge of truss.from outside"16/1-0PRODUCT CODE APPROVALSJOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W
4
-
6
W3-6W3-
7
W2-7W1-7C1-8
C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD
TOP CHORD
87654321BOTTOM CHORDSTOP CHORDSBEARINGLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal InjuryGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:6-4-8dimensions shown in ft-in-sixteenths (Drawings not to scale)' 2012 MiTekfi All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015WEBSedge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W
4
-
6
W3-6W3-
7
W2-7W1-7C1-8
C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD
TOP CHORD
87654321BOTTOM CHORDSTOP CHORDSBEARINGIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8dimensions shown in ft-in-sixteenthsWEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.