HomeMy WebLinkAbout17040069 Building Plans1122334455667788AABBCCDDEE1' - 2 5/8"12' - 7 1/2"3 5/8"7' - 6"6"19' - 5 1/4"3 5/8"9' - 10 7/8"6"6"21' - 9"3"3"29' - 6"3"3"BABAFUTURE TENANT SPACENOT IN SCOPEEXISTING TENANT SPACENOT IN SCOPEMECH ROOMNOT IN SCOPEFUTURE TENANT SPACENOT IN SCOPEAAA HOOSIERMOTOR CLUB105CLASSICCLEANERS106EXTERIOR DOOR(NOT IN SCOPE)EXTERIOR DOOR(NOT IN SCOPE)932 GROSS SF(B OCC.)2,434 GROSS SF(B OCC.)1' - 2 5/8"33' - 0 3/4"3' - 2 5/8"6"36' - 6"6"1' - 2 5/8"WALL PARTITION BETWEEN TENANTS:6" METAL FRAMING WITH (1) LAYER5/8" GYP. BOARD EACH SIDE.PROVIDE BATT INSULATIONPATH OF EGRESS - 95 FT. OF TRAVELPATH OF EGRESS - 42 FT. OF TRAVELOUTDOOR PATIONOT IN SCOPE6" METAL STUDFRAMING WITH (1)LAYER 5/8" GYP. BOARD6" METAL STUDFRAMING WITH(1) LAYER 5/8"GYP. BOARD350 SF/TON HVACROOFTOP UNIT FORCLASSIC CLEANERS59' - 4 7/8"3 5/8"7' - 1 3/8"3 5/8"10' - 4 1/2"3 5/8"7' - 1"6See DrawingCERTIFICATION626 North Illinois StreetIndianapolis, Indiana 46204 Phone: (317) 635-5030 Website: www.bdmd.comBrowning Day Mullins Dierdorf ArchitectsArchitectureLandscape ArchitecturePlanningChecked By:Scale:Issue Date:Drawn By:Project No.:Owner6100 West 96th Street, Suite 150Indianapolis, Indiana 46278 Phone: (317) 344-7300 Website: www.browninginvestments.comBrowning Investements, Inc.4/4/2017 4:41:08 PM C:\Users\jthornberry\Documents\Revit Local Files\14023_Central -MM Building A - 2016 UPGRADE_jthornberry.rvtA100Tenant Fit Out - Floor Plan14023JTNDMarch 28, 2017Meridian & Main Building 1A1438 West Main StreetCarmel, IN 46032Tenant Fit-OutFLOOR PLAN 1/8" = 1'-0"A100AAA/Classic Cleaners Tenant Fit-Out1REVISION SCHEDULERev. # Revision Description Issue Date6 AAA Tenant Update April 4, 2017Description of use: Retail shell building (No tenant fit-out). Two buildings on same site.Building Code: Indiana Building Code, 2008 Edition (IBC, 2006 Edition), ASCE-7-2005.Fire Code: Indiana Fire Code, 2008 Edition (IFC 2006 Edition, 1st printing)Mechanical Code: Indiana Mechanical Code, 2008 Edition (IMC, 2006 Edition, 1st printing)Electrical code: Indiana Electrical Code 2009 Edition (NFPA 70-2008Plumbing code: Indiana Plumbing Code, 2012 EditionFire suppression system: NFPA 13, 2010Energy code: Indiana Energy Conservation Code 2010 (ASHRAE 90.1, 2007 edition, asamended) Occupancy: Unoccupied at this time. Anticipated tenants to be a combination of M, B and A-2.Presume Non-separated, mixed occupancy.Public way or yard, in excess of 30-feet, surrounds each building on all sides.Allowable Building Area (per Table 503 and Section 506):Tabular area for A-2 occupancy; Type V-B construction: 6000 sfAllowable area = 6000 + [6000 x 0.75] + [6000 x 3]Allowable area = 28500 sfProposed building area: Building 1A - 15089 sf; Building 1B - 12100Building height: One-story, roof deck approx 19-feet a.f.f., and parapet approx 26-feet af.f.Construction type required: V-BConstruction type provided for shell: II-B, non-combustible.Fully-sprinklered building. NFPA 13 system.Fire barriers provided: Mechanical rooms, 1-hour rated separation.Fire-resistance rating requirements for building elements (hours) per Table 601:Structural frame: 0Bearing walls exterior/interior: 0/0Non-bearing walls exterior/interior: 0/0Floor construction: n/aRoof construction: 0SHELL BUILDING CODE INFORMATIONConstruction Type: II-B Provided (Type V-B minimum required)Proposed SF: 2,434 SF (AAA Hoosier Motor Club) and 932 SF (Classic Cleaners)Occupancy Type: BFully Sprinklered (see shell building code information)TENANT SPACE CODE INFORMATION