Loading...
HomeMy WebLinkAbout02 Carmel IN_current_BW Signed-RASAKEYSTONE PkwyE. CARMEL DRSITE: #102 E. CARMEL DRIVENORTH1EGRESS PLANNO SCALEHALL/ TOILET ROOMS139.4SF / 0 = 0 OCC.KITCHEN684.6 GSF / 200 = 3 OCC.WAITING AREA200.5 NSF / 7 = 27 OCC.DINING AREA242.8 NSF / 15 = 16 OCC.D IS T A NCE BET WE EN EXI T S 71' - 5"> 1 /3 OV ERA L L DIAG ONAL MAX TRAVEL DISTANCE TO AN EXITS63' - 2"2HUNTERS QUEST TENANT PLANNO SCALEO V ER ALL D I A GO N A L D IS T A N C E 70 ' - 4 "PLUMBING/FIRE SUPPRESSION:1. PROVIDE PLUMBING AND WASTE SUPPLY CONNECTIONS TO ALL EQUIPMENT.2. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL MOP SINK AND HOT WATER HEATER IF NEEDED. MEET ALL APPLICABLE CODE REQUIREMENTS. NOTE: ALL EQUIPMENT MUST BE NSF CERTIFIED AND SATISFY HEALTH CODE REQUIREMENTS. 3. PLUMBING CONTRACTOR TO CAP ANY EXISTING PLUMBING BELOW FLOOR AND TO MEET ALL APPLICABLE CODE REQUIREMENTS.4. PLUMBING CONTRACTOR TO PROVIDE DEDICATED WATER LINE TO 3 COMPARTMENT SINK FOR SANITIZER SYSTEM TO BE INSTALLED BY OTHERS.5. PLUMBING CONTRACTOR TO HOOK-UP FIRE SUPPRESSION IN HOOD SUPPLIED BY TENANT. IF REQUIRED.6. AUTOMATIC FIRE SPRINKLERS SYSTEM, MONITOR, AND ALARMS, ETC TO BE MODIFIED AS REQUIRED TO ACCOMMODATE NEW LAYOUT. IF REQUIRED AND WHERE EXISTS.7. GC TO PROVIDE GREASE INTERCEPTOR IF REQUIRED. VERIFY WITH LOCAL AUTHORITY TYPE, SIZE, AND LOCATION.ELECTRICAL:1. G.C. TO PROVIDE AND INSTALL ALL CONDUIT AND BOXES FOR ELECTRICAL AND LOW VOLTAGE. LOW VOLTAGE CONTRACTOR IS TO PULL WIRES FOR LOW VOLTAGE EQUIPMENT AND HOOK UP. 2. LOW VOLTAGE WIRING AND DATA WIRING BY GC.3. ELECTRICAL CONTRACTOR TO VERIFY EXISTING CONDITIONS TO ACCOMMODATE WIRING OF ALL NEW EQUIPMENT AS SPECIFIED.4. ELECTRICAL CONTRACTOR TO VERIFY THAT THERE IS ADEQUATE EXISTING POWER TO ACCOMMODATE THE PROJECT REQUIREMENTS.5. ELECTRICAL CONTRACTOR TO VERIFY LIGHTING PLAN AND PROVIDE SUFFICIENT LIGHTING LEVELS IN FOOD SERVICE AREAS TO MEET LOCAL HEALTH CODES REQUIREMENTS.6. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL A PHOTO CELL FOR EXTERIOR SIGNAGE. 7. ELECTRICAL CONTRACTOR TO PROVIDE OUTLETS TO MEET ALL APPLICABLE CODES REQUIREMENTS INCLUDING GFI RECEPTACLES IN REQUIRED AREAS.8. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL EXIT AND EMERGENCY LIGHTING TO MEET ALL APPLICABLE CODES.9. GC TO PROVIDE DISPLAY OUTLETS AT ALL STOREFRONT/WINDOWS. VERIFY REQUIREMENTS WITH E/G.10. LIGHT FIXTURE ADJACENT TO OFFICE AREA TO BE ON AT ALL TIMES.11. GC. TO PROVIDE AUTO ON LIGHT SENSOR SWITCHES IN ALL RESTROOMS.MECHANICAL:1. MECHANICAL CONTRACTOR TO REVIEW EXISTING HVAC SYSTEMS FOR SUITABILITY FOR THIS PROJECT. IF SUITABLE, MODIFY EXISTING DISTRIBUTION & RETURNS TO SUIT NEW FLOOR PLAN. IF NOT SUITABLE, PROVIDE NEW RTU AS NEEDED & MODIFY DISTRIBUTIONS, RETURNS FOR NEW FLOOR PLAN.2. MECHANICAL CONTRACTOR TO PROVIDE AND INSTALL SETBACK PROGRAMMABLE THERMOSTAT WITH LOCKABLE BOX. VERIFY LOCATION WITH OWNER.3. MECHANICAL CONTRACTOR TO PROVIDE AND INSTALL EXHAUST HOOD. VERIFY WITH E/G.4. MECHANICAL CONTRACTOR TO PROVIDE ADEQUATE MAKE-UP AIR, PER LOCAL CODES.1. NO DEVIATIONS FROM THESE DOCUMENTS WILL BE ALLOWED WITHOUT PRIOR AUTHORIZATION FROM E/G CORPORATE REPRESENTATIVE AND MUST BE IN WRITING.2. VERIFY ALL WORK WITH OWNER/TENANT PRIOR TO CONSTRUCTION.3. ALL MECHANICAL, ELECTRICAL, AND WATER SYSTEMS, WITHIN MULTI-TENANT BUILDINGS, SHALL BE SEPARATED FROM EXISTING TENANT SPACE. GC TO PROVIDE COMPLETE SEPARATION AS REQUIRED.4. GENERAL CONTRACTOR TO PROVIDE A DETAILED CONSTRUCTION SCHEDULE.5. GENERAL CONTRACTOR TO PROVIDE LOW VOLTAGE INSTALLATION DATE ON CONSTRUCTION SCHEDULE AND MANAGE/COORDINATE LOW VOLTAGE CONTRACTOR AND E/G. 6. GENERAL CONTRACTOR TO BE RESPONSIBLE TO SCHEDULE AND COORDINATE ALL REQUIRED INSPECTIONS INCLUDING BUILDING, ENGINEERING, AND HEALTH DEPARTMENT INSPECTIONS, AND MUST SECURE A CERTIFICATE OF OCCUPANCY UPON COMPLETION OF THE PROJECT.7. GENERAL CONTRACTOR TO BE RESPONSIBLE TO HIRE AND COORDINATE THE BUILDING OWNER'S DESIGNATED ROOFING CONTRACTOR. CONTRACTOR TO SEAL ANY AND ALL ROOF PENETRATIONS RELATED TO THE PROJECT AND TO ENSURE MAINTENANCE OF EXISTING WARRANTIES.8. MECHANICAL, PLUMBING AND ELECTRICAL ROUGH IN SLEEVES AND CONDUITS ARE TO BE TERMINATED NO HIGHER THAT 5” ABOVE SLAB TO ACCOMMODATE MILLWORK INSTALLATION.9. DIMENSIONS AND BUILDING LOCATION ON THIS SITE ARE BASED ON BEST AVAILABLE INFORMATION AT THE TIME OF LAYOUT. DEVIATIONS MAY BE NECESSARY IN THE FIELD. ANY SUCH CHANGES OR CONFLICTS BETWEEN THIS PLAN AND FIELD CONDITIONS ARE TO BE REPORTED TO THE ARCHITECT PRIOR TO STARTING CONSTRUCTION.10. ALL CONSTRUCTION OF UTILITIES TO BE IN ACCORDANCE WITH LOCAL BUILDING CODES.11. LOCATION OF UNDERGROUND UTILITIES, EXISTING OR PROPOSED, AS DEPICTED HEREIN, ARE APPROXIMATE OR SCHEMATIC. LOCATION OF EXISTING UTILITIES MUST BE VERIFIED IN THE FIELD PRIOR TO CONSTRUCTION.12. GENERAL CONTRACTOR TO MAINTAIN A CLEAN AND ORDERLY CONSTRUCTION SITE AND REMOVE ALL CONSTRUCTION DEBRIS AT COMPLETION OF PROJECT TO OWNER'S EXPECTATIONS.13. GENERAL CONTRACTOR IS RESPONSIBLE FOR FINAL CLEANING OF THE RESTAURANT. THE RESTAURANT SHALL BE COMPLETELY CLEANED AND IN READY TO OPEN CONDITION PRIOR TO DELIVERY OF FOOD AND PRODUTS. 14. GENERAL CONTRACTOR TO COORDINATE WITH TENANT, THE FINAL SCOPE OF WORK. INCLUDING WORK NOT SHOWN IN THIS SET AND WHAT MATERIALS, ASSEMBLIES AND FINISHES TO BE KEPT SALVAGED OR REUSED.15. MECHANICAL/ELECTRICAL/LOW VOLTAGE, GENERAL CONTRACTOR TO PROVIDE AND COORDINATE THE APPROPRIATE SUBTRADES WHO WILL PROVIDE DESIGN-BUILD DOCUMENTS FOR ALL WORK NECESSARY FOR A COMPLETE & OPERATIONAL RESTAURANT INCLUDING PERMITS. ALL SUCH WORK HVAC, ELECTRICAL, LIGHTING, LOW VOLTAGE, AND PLUMBING TO MEET ALL STATE AND LOCAL CODES.16. GENERAL CONTRACTOR TO PROVIDE AND INSTALL FIRE EXTINGUISHERS PER FIRE MARSHALS DIRECTION.17. GENERAL CONTRACTOR TO BE RESPONSIBLE FOR SUPPLY AND INSTALLATION OF ALL WALL BACKING FOR ALL WALL HUNG ITEMS.18. ALL WIRE AND SS SHELVING SHALL BE SUPPLIED BY THE FOOD SERVICE EQUIPMENT SUPPLIER OR OWNER. VERIFY DURING BID PROCESS.19. ALL FIRE ALARM SYSTEM DESIGN AND FIRE SUPPRESSION SYSTEMS DESIGN TO BE PROVIDED BY THE AWARDED CONTRACTOR .20. GC. TO PROVIDE BID FOR SUPPLY AND INSTALLATION OF ALL MILLWORK AS SHOWN ON MILLWORK PAGES.21. ALL NEW WALLS THAT HAVE DOORS INSTALLED SHALL HAVE WALLS THAT EXTEND OR ARE BRACED TO PROVIDE PROPER DOOR ANCHORAGE.22. GENERAL CONTRACTOR IS RESPONSIBLE FOR DATA WORK TO BE INCLUDED IN THEIR BID. ERBERT AND GERBERT'SSANDWICH SHOPHUNTERS QUEST102 E. CARMEL DRIVECARMEL, IN 46033COVCOVER SHEETFRANCHISORERBERT & GERBERT'S5828 ARNDT ROADEAU CLAIRE, WI 54701 CONTACT: GUY ROSSATOPHONE: 715-579-6287EMAIL: grossato@egsubs.comCONTACTSFRANCHISEETRGT Ventures, Inc.14586 CHERRY RIDGE ROADCARMEL, IN 46033CONTACT: TROY BRUINSMAPHONE: 727 269 0177MAIL:troy.bruinsma@gmail.comENGINEER, STRUCTURALMcCOMAS ENGINEERING1717 EAST 116TH STREET, SUITE 200CARMEL, IN 46032CONTACT: ROD McCOMASPHONE: 317-580-0402 EXT 301EMAIL: rmccomas@mccomaseng.comTENANT IMPROVEMENT: RESTAURANT AS NEW TENANT IN A MULTI TENANT SINGLE STORY BUILDING. CHANGE OF USE: NONE, GROUP B PER 303.1 EXCEPTION #1PROJECT DESCRIPTIONLOCATION MAPCURRENT ISSUEISSUED FOR REFERENCE ONLYPREVIOUS ISSUENOT ISSUEDDRAWING SCHEDULECOV COVER SHEETALTA SURVEYAS-0 ZONING EXHIBITAS-1 SITE PLAN AND DRIVE THRU DETAILSAS-2 DRIVE THRU EQUIPMENT DETAILSAS-2 DRIVE THRU EQUIPMENT DETAILSAD-1 DEMO PLANA-1 FLOOR PLANA-2 FINISH PLAN AND GRAPHICSA-3 REFLECTED CEILING AND TECHNOLOGY PLANA-4 INTERIOR ELEVATIONSA-4.1 EXTERIOR ELEVATIONSA-5 MILLWORKA-5.1 MILLWORKA-5.2 MILLWORKFS-1 EQUIPMENT PLANFS-2 EQUIPMENT SCHEDULEFS-3 EQUIPMENT SCHEDULEM1.1 HVA/C PLANP1.1 PLUMBING PLANP2.1 PLUMBING RISERSP3.1 PLUMBING DETAILS AND SCHEDULESE1.1 LIGHTING PLANE2.1 POWER PLANLANDLORDThe Fineberg Group, LLC1 EAST CARMEL DRIVESUITE 200CARMEL, IN CONTACT: DAVID FINEBERGPHONE: 317 844 3993MAIL: david@fineberggroup.comARCHITECTRYAN A SCHROEDER,ARCHITECT, INC4931 WEST 35TH STREET, SUITE 200ST. LOUIS PARK, MN 55416 CONTACT: CHAD BERREAUPHONE: 952-541-9969EMAIL:chad.berreau@planforcegroup.comFOOD SERVICE EQUIPMENT SUPPLIERTBD???CONTACT: ???PHONE: ???EMAIL: ???ISSUED FOR:CORPORATE REVIEW 03.31.2017GENERAL NOTESISSUED FOR:IDHS CDR REVIEWBUILDING & HEALTH REVIEW04.06.2017APPLICABLE CODES2014 INDIANA BUILDING CODE (IBC 2012) & ANSI A117.1-20092012 INDIANA PLUMBING CODE2009 INDIANA ELECTRICAL CODE ( NFPA-70-2008)2014 INDIANA MECHANICAL CODE (IMC 2012)INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1 2007)2014 INDIANA FIRE CODE (IFC 2012) INTERNATIONAL CODES, AS AMENDED: IBC, IFC, IPC ZONING DISTRICT: BUSINESS DISTRICTB-8OVERLAY DISTRICT: RANGE LINE / CARMEL DR CARMELTYPE OF CONSRUCTION:V-BNUMBER OF STORIES:1AREA ALLOWED: [9,000 + (9,000(0.72)) + (6,000(0)) = 15,480 SFBUILDING AREA: (PER FLOOR)13,459 SFTENANT: ERBERT & GERBERT'S:1448.3 GROSS SF+-1326.7 NET SF +-SEATING:20 SEATSOCCUPANT LOAD47 OCCUPANTSOCCUPANCYPER 303.1 Exception #1 GROUP BASSEMBLY OCCUPANCY (DINING AREA) A-2: < 50 OCC, 443.3 NET SF+/- OCCUPANT LOAD CALCULATIONS SF FACTOR OCCUPANTSDINING AREA: 242.8 15 16.2WAITING AREA: 200.5 7 28.6KITCHEN: 684.6 200 3.4HALL/TOILET: 139.4 0 0.0CONSTRUCTION 50.3 0 0.0TOTAL: 1326.7 SF 47.2AUTOMATIC SPRINKLERS REQUIRED: (MIXED USE OCCUPANCY) NOAUTOMATIC SPRINKLERS PROVIDED:NONEAREA SEPARATIONS:REQUIRED: (SEPERATED OCCUPANCY, TABLE 508.4, SPRINKLED 1 HOURPROVIDED:EXISTINGEXITS, TENANT SPACEREQUIRED:2PROVIDED:2EXITS, DINING AREAREQUIRED:1PROVIDED:1RESTROOMS GENDER SEPARATE: (W/ 1 LAV AND 1 TOILET IN EACH) YESLAYOUT REQUIREMENTS: A117.1-2009, IBC, IPC, WATER CLOSETS REQUIRED:1WATER CLOSETS PROVIDED:1URINALS REQUIRED:0URINALS PROVIDED:0LAVATORIES REQUIRED:1LAVATORIES PROVIDED:1CODE ANAYLSISENGINEER, MEPEMR, LLC4236 HIGHWAY 3630ANNVILLE, KY 40402CONTACT: ROBERT C MURRAYPHONE: 606-364-2886 EXT 14EMAIL: robert@emrengineers.com18' 7 1/2"70' 6 1/2"18' 9 1/2"GENERAL CONTRACTORSPECTRE BUILDING GROUP6203 FERMAN AVENUEMAPLE LAKE, MN 55358CONTACT: GREG MOONEYPHONE: 612-385-8410ISSUED FOR:IDHS CDR REVIEWREVISION #104.26.2017AR11600168PRELIMINARY CONCEPT 1 03.08.2017ERBERT& GERBERT'SSANDWICH SHOPPRINT HISTORY DATEPROJECT:DRAWN:CHECKED:SIGNATURE:REGISTRATION:I hereby certify the this plan was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of INDIANARYAN SCHROEDER17020CBRS102 E. CARMEL DRCARMEL, INDIANAERBERT& GERBERT'SSANDWICH SHOPFINAL CONCEPT 03.16.2017CORPORATE REVIEW 03.31.2017BUILDING / HEALTH REVIEW 04.06.2017HUNTERS QUEST102 E. CARMEL DRIVECARMEL, IN 46033EXPLORATORY EXHIBIT 02.21.2017LANDLORD PRELIM REVIEW 03.28.2017CDR REVISION / REVISION #1 04.26.201704.26.2017 SITE PLAN NOTES1. SITE WORK IS LIMITED, THIS PROJECT. WORK INVOLVES INSTALLATION OF DRIVE THRU MENU BOARD AS DEPICTED THIS PLAN.2. ALL LANDSCAPING IS EXISTING TO REMAIN. 3. CONTRACTOR SHALL PATCH AND REPAIR DAMAGE TO PAVEMENT, LANDSCAPING AND IRIGATION SYSTEMS AS A RESULT OF IMPROVEMENTS HEREIN DESRIBED.4. DRIVE THRU WINDOW AND DRIVE LANE ARE EXISTING TO REMAIN.5. SHEETS AS-2 & AS-3 CONTAIN REPRESENTATIVE DRIVE MENU BOARD DETAILS AND INFORMATION. THIS INFORMATION IS NOT SITE SPECIFIC.6. TENANT SIGNAGE PACKAGE NOT DEPICTED. TENANT SIGNAGE DESIGN BY OTHERS.SITE PLAN KEY NOTES1. LOCATION OF EXISTING ENTRY.2. LOCATION OF EXISTING SERVICE DOOR.3. EXISTING STOREFRONT WINDOW.4. NEW STOREFRONT WINDOW.5. LOCATION OF EXISTING PICK-UP WINDOW.6. DRIVE THRU CUSTOMER QUE.7. NEW CONCRETE SLAB, RAISED 6" ABOVE PAVEMENT ELEVATION. DETAILS TO MATCH CENTER STANDARDS.8. NEW 48" HIGH, 6" DIAMETER STEEL BOLLARD FILLED WITH CONCRETE. PAINT. EMBED 48" MIN. WITHIN 18” DIAMETER CONCRETE FOUNDATION INSTALLED 54” BELOW FINISH GRADE.9. NEW DRIVE THRU SPEAKER BOX. VERIFY STYLE WITH E/G. PROVIDE 18” DIAMETER CONCRETE FOUNDATION MIN. 24” BELOW FINISH GRADE OR 6” BELOW LOCAL FROST DEPTH, WHICHEVER IS GREATEST. PROVIDE SEPARATE POWER AND DATA CONDUITS CONNECTING BACK TO EG EQUIPMENT. ELECTRICAL CONTRACTOR TO MAKE ALL CONNECTIONS.10. NEW DRIVE THRU MENU BOARD. VERIFY STYLE WITH E/G. PROVIDE 24” DIAMETER CONCRETE FOUNDATION MIN. 48” BELOW FINISH GRADE OR 6” BELOW LOCAL FROST DEPTH, WHICHEVER IS GREATEST. PROVIDE SEPARATE POWER AND DATA CONDUITS CONNECTING BACK TO EG EQUIPMENT. ELECTRICAL CONTRACTOR TO MAKE ALL CONNECTIONS.11. LOCATION OF ELECTRICAL AND DATA CONDUITS FROM DRIVE THRU MENU BOARD TO TENANT SPACE. DATA SHALL BE RUN SEPARATE CONDUIT AND KEPT SEPARATE FROM POWER12. SIDEWALK, FRONT: EXISTING TO REMAIN.13. ACCESSIBLE CURB CUT: EXISTING TO REMAIN.14. ACCESSIBLE PARKING: EXISTING TO REMAIN.15. PARKING: EXISTING TO REMAIN.16. ACCESS AISLE: EXISTING TO REMAIN.17. SIDEWALK, REAR: EXISTING TO REMAIN.18. GRADE MOUNTED CONDENSOR LOCATION(S). SEE MECHANICAL.19. GRADE MOUNTED HOSE SHED, TO BE RELOCATED AS REQUIRED. COORDINATE WITH LANDLORD. SEE MECHANICAL.20. SIGNAGE, PARKING: PROVIDE AND INSTALL (1) SIGNAGE "FOR ERBERT AND GERBERT DELIVERY DRIVER ONLY. AND LOCATE ADJACENT TO SERVICE ENTRANCE.21. EXISTING TRASH DUMPSTER TO REMAIN.22. EXISTING FOUNDATION LANDSCAPING TO REMAIN23. EXISTING COVERED ENTRY.24. ERBERT AND GERBERT'S SIGNAGE. MOUNTED ONTO EXISTING MONUMENT SIGN CABINET. WORK PERFORMED BY SEPARATE PERMIT.25. ERBERT AND GERBERT'S WALL MOUNTED SIGNAGE, WORK PERFORMED BY SEPARATE PERMIT.26. ERBERT AND GERBERT'S WALL MOUNTED CANVAS, WITH SIGANGE, WORK PERFORMED BY SEPARATE PERMIT.27. ERBERT AND GERBERT’S PEDESTAL DRIVE THRU DIRECTIONAL SIGNAGE. WORK PERFORMED BY SEPARATE PERMIT. ELECTRICAL TO PROVIDE POWER WHERE REQUIRED.28. NEW DRIVE THRU CLEARANCE BAR. SET AND LABELED TO MATCH CLEARANCE AT DRIVE THRU WINDOW OPENING. KEYNOTE #AS-1SITE PLANSITE PLAN 1"=20'-0"14' 10"1' 3"10"3' 9"6' 11"2' 0"2' 0"DRIVE THRU MENU BOARD ELEVATION 1/4"=1'-0"2TENANT SPACEN.I.C.12621510121315161618202124PROPERTY LINEPROPERTY LINEPROPERTY LINEUTILITY EASEMENT(S)232753252514171122417' 5"9' 3"778897669819810891675"70' 6"E&G TENANT SPACELIMIT OF CONSTRUCTION18' 7"E&G TENANT SPACELIMIT OF CONSTRUCTIONADJACENT TENANT SPACE(S)AREA(S) N.I.C.DRIVE THRU LANE & PARKING AREALIMITED CONSTRUCTION22284' 0"2826' 9"42' 9"115' 4"105' 11"AR11600168PRELIMINARY CONCEPT 1 03.08.2017ERBERT& GERBERT'SSANDWICH SHOPPRINT HISTORY DATEPROJECT:DRAWN:CHECKED:SIGNATURE:REGISTRATION:I hereby certify the this plan was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of INDIANARYAN SCHROEDER17020CBRS102 E. CARMEL DRCARMEL, INDIANAERBERT& GERBERT'SSANDWICH SHOPFINAL CONCEPT 03.16.2017CORPORATE REVIEW 03.31.2017BUILDING / HEALTH REVIEW 04.06.2017HUNTERS QUEST102 E. CARMEL DRIVECARMEL, IN 46033EXPLORATORY EXHIBIT 02.21.2017LANDLORD PRELIM REVIEW 03.28.2017CDR REVISION / REVISION #1 04.26.2017 AS-2DRIVE THRU EQUIPMENT DETAILSAR11600168PRELIMINARY CONCEPT 1 03.08.2017ERBERT& GERBERT'SSANDWICH SHOPPRINT HISTORY DATEPROJECT:DRAWN:CHECKED:SIGNATURE:REGISTRATION:I hereby certify the this plan was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of INDIANARYAN SCHROEDER17020CBRS102 E. CARMEL DRCARMEL, INDIANAERBERT& GERBERT'SSANDWICH SHOPFINAL CONCEPT 03.16.2017CORPORATE REVIEW 03.31.2017BUILDING / HEALTH REVIEW 04.06.2017HUNTERS QUEST102 E. CARMEL DRIVECARMEL, IN 46033EXPLORATORY EXHIBIT 02.21.2017LANDLORD PRELIM REVIEW 03.28.2017CDR REVISION / REVISION #1 04.26.2017 AS-3DRIVE THRU EQUIPMENT DETAILSAR11600168PRELIMINARY CONCEPT 1 03.08.2017ERBERT& GERBERT'SSANDWICH SHOPPRINT HISTORY DATEPROJECT:DRAWN:CHECKED:SIGNATURE:REGISTRATION:I hereby certify the this plan was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of INDIANARYAN SCHROEDER17020CBRS102 E. CARMEL DRCARMEL, INDIANAERBERT& GERBERT'SSANDWICH SHOPFINAL CONCEPT 03.16.2017CORPORATE REVIEW 03.31.2017BUILDING / HEALTH REVIEW 04.06.2017HUNTERS QUEST102 E. CARMEL DRIVECARMEL, IN 46033EXPLORATORY EXHIBIT 02.21.2017LANDLORD PRELIM REVIEW 03.28.2017CDR REVISION / REVISION #1 04.26.2017 EXISTING WALL CONSTRUCTION TO REMAIN. REMOVE EXISTING WALL CONSTRUCTION.WALL TYPESEXDMGENERAL DEMOLITION NOTES1. THE INTENT OF THIS DRAWING IS TO DOCUMENT THE DEMOLITION OF PARTITIONS, FLOORS, CEILINGS, WALLS, DOORS, ETC.2. BIDDING INSTRUCTIONS: ALL CONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH THE EXISTING BUILDING SITE, THE PROPOSED NEW CONSTRUCTION AND THE DEMOLITION SCOPE OF WORK PRIOR TO SUBMITTING THEIR BID. INFORMATION SHOWN ON THIS DEMOLITION PLAN IS INTENDED TO BE AS COMPLETE AS POSSIBLE, BUT THERE MAY BE ITEMS MISSED OR INCIDENTAL TO NEW CONSTRUCTION THAT ARE NOT SHOWN. THEREFORE DEMOLITION IS NOT NECESSARILY LIMITED TO THOSE ITEMS SHOWN ON THESE DEMOLITION PLANS. BIDS MUST INCLUDE ALL DEMOLITION REQUIRED TO FULFILL CONSTRUCTION OF THIS ENTIRE SET OF DOCUMENTS.3. IT IS THE RESPONSIBILITY OF THE DEMOLITION CONTRACTOR TO KNOW AND FOLLOW ALL LAWS, REGULATIONS, ORDINANCES, AND CODES ENACTED AND ENFORCED BY APPLICABLE FEDERAL, STATE, AND LOCAL AGENCIES WITH JURISDICTION AT THE SITE.4. THE DEMOLITION CONTRACTOR IS RESPONSIBLE FOR THE SAFE REMOVAL AND DISPOSAL OF ALL DEMOLISHED MATERIALS, EXCEPT FOR THOSE MATERIALS SPECIFIED TO BE SAFELY STORED FOR RE-USE. THE DEMOLITION CONTRACTOR SHALL COORDINATE THE STORAGE OF SUCH MATERIALS WITH THE GENERAL CONTRACTOR.5. THE DEMOLITION CONTRACTOR IS RESPONSIBLE TO REPORT THE DISCOVERY OF ANY FOUND DEFECTS IN MATERIALS OR SYSTEMS TO REMAIN OR HAZARDOUS MATERIALS ENCOUNTERED TO THE GENERAL CONTRACTOR, THE OWNER AND THE ARCHITECT IN A TIMELY MANNER. SUCH DISCOVERY MAY NOT IMPACT THE CONSTRUCTION SCHEDULE SET FORTH.6. THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY, PRIOR TO BEGINNING ANY WORK ON THE SPACE (DEMOLITION & CONSTRUCTION). THE LOCATION OF ALL UTILITIES AND SERVICES TO THE SPACE. IF ANY OF THESE ARE FOUND TO BE IN CONFLICT WITH THE PROPOSED NEW CONSTRUCTION CONTACT THE ARCHITECT IMMEDIATELY.7. VERIFY ALL LOCATIONS OF NEW WALLS, DOORS, OPENINGS, ETC. WITH THE DRAWINGS.8. PATCH ALL WALLS, FLOORS, CEILINGS, ETC. TO REMAIN, THAT ARE DAMAGED DURING DEMOLITION OR CONSTRUCTION AS REQUIRED TO BE READY TO RECEIVE NEW FINISH MATERIALS.9. XRAY OF FLOOR TO BE DONE PRIOR TO ANY PENETRATIONS. NOTIFY E/G IF REQUIRED.10. ELECTRICAL INFORMATION IS SHOWN FOR REFERENCE ONLY. SUCONTRACTOR IS RESPONSIBLE TO REVIEW THE EXISTING INSTALLATION AND THE POWER REQUIREMENTS FOR THE PROPOSED EQUIPMENT PRIOR TO BID.DEMOLITION KEY NOTESA. REMOVE EXISTING STUD WALL. REMOVE ALL DOORS, FRAMES, FINISHES, ETC. IN CONFLICT WITH NEW CONSTRUCTION.B. SAWCUT AND REMOVE MASONRY WALL CONSTRUCTION AS REQUIRED FOR INSTALLATION OF NEW WINDOW OPENING. REFER TO STRUCTURAL DETAILS SHEET A1.1. SHORING DESIGN BY OTHERS.C. EXISTING STOREFRONT OPENINGS TO REMAIN: INCLUDING STOREFRONT ENTRANCE, SERVICE DOOR, DRIVE THRU WINDOW AND FRONT WINDOW. MODIFY EXISTING HARDWARE AS NOTED. D. REMOVE ALL WALL FINISHES AND ACCESSORIES, ON WALLS TO REMAIN, IN CONFLICT WITH NEW CONSTRUCTION, PATCH ALL SURFACES TO RECEIVE NEW FINISHES.E. REMOVE ALL FLOOR AND BASE FINISHES IN CONFLICT WITH NEW CONSTRUCTION, PATCH ALL SURFACES TO RECEIVE NEW FINISHES.F. EXISTING FURNISHING, FINISHES AND EQUIPMENT TO BE REMOVED, UNLESS OTHERWISE NOTED THIS CONSTRUCTION DOCUMENT SET.G. MODIFY EXISTING CEILING AS REQUIRED FOR NEW CONSTRUCTION. SEE REFLECTED CEILING PLAN FOR MORE INFORMATION AND NEW FINISHES.H. WATER METER, VERIFY.I. NOT USED EXISTING FOOD, OIL AND GREASE SEPARATOR, VERIFY. RELOCATE AS REQUIRED FOR NEW CONSTRUCTION.J. MODIFY LOCATION FOR EXISTING WASTE LINES AS REQUIRED FOR NEW CONSTRUCTION. K. REMOVE EXISTING TOILET AND LAVATORY SINK. L. REMOVE EXISTING UTILITY SINK. M. REMOVE EXISTING WATER HEATER, TO BE REPLACED AND RELOCATED. SEE FLOOR PLAN FOR PROPOSED LOCATION. SEE EQUIPMENT SCHEDULE FOR REQUIREMENTS.N. MODIFY EXISTING MECHANICAL SYSTEM, AS REQUIRED, INCLUDING DUCTWORK TO ACCOMMODATE NEW LAYOUT. SEE MECHANICAL DRAWINGS AND REFLECTED CEILING PLAN FOR MORE INFORMATION.O. ELECTRICAL PANEL, TO BE RELOCATED. SEE ELECTRICAL DRAWINGS.P. ELECTRICAL SERVICE, VERIFY POWER REQUIREMENTS AND PROVIDE AS REQUIRED. SEE ELECTRICAL DRAWINGS.-DEMO PLAN: MAIN LEVEL 1/4"=1'-0"170' 6"E&G TENANT SPACELIMIT OF CONSTRUCTION18' 7"E&G TENANT SPACELIMIT OF CONSTRUCTIONADJ TENANT - N.I.C.ADJACENT TENANT SPACE(S)AREA(S) N.I.C.ADJ TENANT - N.I.C.DRIVE THRU LANE & PARKING AREALIMITED CONSTRUCTION18' 9"E&G TENANT SPACELIMIT OF CONSTRUCTIONADJACENT TENANT SPACE(S)AREA(S) N.I.C.EXHEXEXEXEXEXEXDMDMDMDMDMEXAAAAB BCCCCEDFGNEDFGNEDFGNEDFGNEDFGNJKLMOPAD-1DEMO PLANNOTE: SHORE EXISTING ROOF TRUSSES AS REQUIRED FOR NEW CONSTRUCTION. SHORING DESIGN BY OTHERS.AR11600168PRELIMINARY CONCEPT 1 03.08.2017ERBERT& GERBERT'SSANDWICH SHOPPRINT HISTORY DATEPROJECT:DRAWN:CHECKED:SIGNATURE:REGISTRATION:I hereby certify the this plan was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of INDIANARYAN SCHROEDER17020CBRS102 E. CARMEL DRCARMEL, INDIANAERBERT& GERBERT'SSANDWICH SHOPFINAL CONCEPT 03.16.2017CORPORATE REVIEW 03.31.2017BUILDING / HEALTH REVIEW 04.06.2017HUNTERS QUEST102 E. CARMEL DRIVECARMEL, IN 46033EXPLORATORY EXHIBIT 02.21.2017LANDLORD PRELIM REVIEW 03.28.2017CDR REVISION / REVISION #1 04.26.2017 SITE1. SIDEWALK: EXISTING SIDEWALK W/ STOOP TO REMAIN.2. STOOP: EXISTING CONDITIONS TO REMAIN. 3. PATIO: NOT USED. PLAN10. EXTERIOR WALL: EXISTING TO REMAIN. REPAIR AND PATCH AS REQUIRED TO A LEVEL 4 FINISH MINIMUM WHERE PAINTED. . 11. STOREFRONT, ENTRANCE: EXISTING TO REMAIN, VERIFY SWING & LOCATION OF DOOR OPENINGS. 11A. STOREFRONT, WINDOW: EXISTING TO REMAIN. 11B. STOREFRONT, WINDOW: NEW TO BE INSTALLED IN EXISTING MASONRY BEARING WALL. WINDOW TO MATCH EXISTING STYLE, DIMENSIONS AND FINISHES.11C. PRIVACY FILM: EG GRAPHIC / WINDOW FILM SHALL BE INSTALLED ON GLAZING ADJOINING HIGH COUNTER LOCATIONS. SEE SHEET A4 FOR LOCATION. 12. DEMISING WALL: EXISTING TO REMAIN. MAINTAIN PARTITION ASSEMBLY RATINGS. 12A. PLENUM ENCLOSURES: EXISTING TO REMAIN. MAINTAIN BARRIER ASSEMBLY RATINGS.13. TOILET ROOM: PROVIDE ACCESSIBLE TOILET ROOM. TOILET AND SINK FIXTURES SHALL BE PER BUILDING STANDARD, WHERE SPEC EXISTS. ACCESSORIES SHALL BE PER EG FOR GRAB BARS, TOILET PAPER HOLDER, MIRROR. PAPER TOWEL DISPENSER, SOAP DISPENSER, COAT HOOK ETC. SEE PLAN 2 & 3/A-1 FOR LOCATION OF ACCESSIBLE CLEARANCES TO BE MAINTAINED.14. PROOFER OVEN / TYPE II HOOD WALL CONSTRUCTION: PROVIDE WALL TYPE "W4", A SUBSTRATE SUBSTITUTION FOR CEMENT BOARD FRAMING. WALL TYPE "W4" MODIFIES WALL TYPE(S) "EX" OR "W1A" OR "W2/W2A" WIDTH AND DEPTH OF THE HOOD FROM FLOOR TO TOP OF TYPE II HOOD. SEE FINISH PLAN FOR NON-COMBUSTIBLE FINISH.15. BEVERAGE LINES: BEVERAGE MACHINE LINES FROM BAG IN BOX ROUTED TO CEILING ABOVE AND OUT TO BEVERAGE MACHINE.16. BEVERAGE LINES CHASE: PROVIDE STAINLESS STEEL CHASE OR EITHER PVC CHASE IN WALL FROM CEILNG TO TOP OF BEVERAGE MACHINE.17. WAINSCOT, DINING AREA: PROVIDE AND INSTALL WAINSCOT THROUGHOUT, SEE INTERIOR FINISH PLAN AND INTERIOR ELEVATIONS FOR EXTENTS AND DETAIL.DOOR & HARDWAREALL DOOR HARDWARE SPEC TO BE ALLEGION THIS LOCATION - STEEL CRAFT DOORS, SCHLAGE LOCKS, IVES HINGES, LCN CLOSURES, VON DUPRIN EXIT DEVICES20. DOOR #100 - STOREFRONT ENTRANCE W/ EGRESS HARDWARE: EXISTING STOREFRONT DOOR & FRAME, WITH GLAZING, PREFINISHED TO REMAIN. FIELD VERIFY EXISTNG CONDITIONS. PROVIDE DOOR HARDWARE AS REQUIRED INCLUDING HINGES, PULL HANDLE, DEADLATCH SET W/ PANIC BAR RELEASE (EXCLUDE PANIC AT MAIN ENTRANCE DOOR #100 PER CODE) KEYED LOCKING CYLINDER (KEYED AS PER OWNER) AND CLOSURE. PROVIDE SIGNAGE “DOOR SHALL REMAIN UNLOCKED WHEN DINING ROOM OPEN.”21. DOOR #101 - SERVICE DOOR: EXISTING 3'-0" X 7'-0" METAL DOOR AND METAL FRAME TO REMAIN. PAINT. VERIFY AND PROVIDE DOOR HARDWARE INCLUDING CLOSURE, HINGES, STORE DOOR LOCKSET W/ LEVER HANDLES AND KICKPLATE EACH SIDE OF DOOR VERIFY AND. PROVIDE WITH CONTIOUS DRIP EDGE ALONG HEAD OF DOOR. PROVIDE W/ SECURITY GLASS EYE VIEWER. PROVIDE SIGNAGE “EMPLOYEE ENTRANCE ONLY”22. DOORS # 103 & 104 - TOILET ROOM DOOR: NEW 3'-0" X 6'-8" SOLID WOOD DOOR AND FRAME (PAINT GRADE). PAINT. PROVIDE DOOR HARDWARE INCLUDING CLOSURE, HINGES, PUBLIC RESTROOM LOCKSET AND KICK PLATE EACH SIDE. PROVIDE RESTROOOM SIGNAGE.23. NOT USED -EMPLOYEE TRAFFIC DOOR (PASSAGE): 3'-0" X 6'-8" SOLID WOOD DOOR, WITH TEMPERED GLASS HALF LITE, AND FRAME (PAINT GRADE). PAINT. PROVIDE DOOR HARDWARE INCLUDING CLOSURE, HINGES, PASSAGE SET W/ LEVER HANDLES, KICKPLATE EACH SIDE OF DOOR, AND FLOOR MOUNTED DOOR STOP. PROVIDE EMPLOYEE ONLY SIGNAGE.24. NOT USED - OFFICE DOOR: NEW 3'-0" X 6'-8" SOLID WOOD DOOR AND FRAME (PAINT GRADE). PAINT. PROVIDE DOOR HARDWARE INCLUDING CLOSURE, HINGES, PRIVACY LOCKSET AND KICK PLATE EACH SIDE.25. NOT USED - STORAGE DOOR: NEW 3'-0" X 6'-8" SOLID WOOD DOOR AND FRAME (PAINT GRADE). PAINT. PROVIDE DOOR HARDWARE INCLUDING CLOSURE, HINGES, STORAGE LOCKSET AND KICK PLATE EACH SIDE.26. NOT USED - EMPLOYEE DOUBLE ACTING, NON HANDEDED, SINGLE SERVICE TRAFFIC DOOR (IMPACT): 3'-0" X 6'-8" DOOR (SOLID WOOD PAINT GRADE), WITH TEMPERED GLASS HALF LITE, AND CASED OPENING FRAME (SOLID WOOD PAINT GRADE). PAINT. PROVIDE DOOR HARDWARE INCLUDING DOUBLE ACTING DOOR CLOSURE & HINGE, PUSH PLATES & KICKPLATE EACH SIDE OF DOOR. PROVIDE EMPLOYEE ONLY SIGNAGE.27 DOOR #102 – DRIVE THRU WINDOW: EXISTING TO REMAIN. VERIFY EXISTING CONDITIONS. PROVIDE DOOR HARDWARE AS REQUIRED.MILLWORK30. POS COUNTER: BY MILLWORK PROVIDER. SEE MILLWORK DRAWINGS. PROVIDE SHOP DRAWINGS TO DESIGNER PRIOR TO CONSTRUCTION.31. CHIPS DISPLAY COUNTER: BY MILLWORK PROVIDER. SEE MILLWORK DRAWINGS. PROVIDE SHOP DRAWINGS TO DESIGNER PRIOR TO CONSTRUCTION32. MAKE TABLE WALL: BY MILLWORK PROVIDER. SEE MILLWORK DRAWINGS. PROVIDE SHOP DRAWINGS TO DESIGNER PRIOR TO CONSTRUCTION33. SODA STATION, CUSTOMER: BY MILLWORK PROVIDER. SEE MILWORK DRAWINGS. PROVIDE SHOP DRAWINGS TO DESIGNER PRIOR TO CONSTRUCTION.34. DINING ROOM FURNISHINGS: SEATING, CHAIRS, TABLES AND LEGS, DINING COUNTERS AND BOOTHS, BY MILLWORK PROVIDER. SEE MILWORK DRAWINGS. PROVIDE SHOP DRAWINGS TO DESIGNER PRIOR TO CONSTRUCTION.35. DINING COUNTER SUPPORTS: WALL MOUNTED SUPPORTS BY MILLWORK PROVIDER. SEE MILWORK DRAWINGS. PROVIDE SHOP DRAWINGS TO DESIGNER PRIOR TO CONSTRUCTION.36. DINING COUNTER SUPPORTS: FLOOR SUPPORTED BOLT DOWN BASE. BY MILLWORK PROVIDER. SEE MILWORK DRAWINGS. PROVIDE SHOP DRAWINGS TO DESIGNER PRIOR TO CONSTRUCTION.37. TRASH: BY MILLWORK PROVIDER. SEE MILWORK DRAWINGS. PROVIDE SHOP DRAWINGS TO DESIGNER PRIOR TO CONSTRUCTION.38. DELIVERY STATION: BY MILLWORK PROVIDER. SEE MILWORK DRAWINGS. PROVIDE SHOP DRAWINGS TO DESIGNER PRIOR TO CONSTRUCTION.39. OFFICE DESK: BY MILLWORK PROVIDER. SEE MILWORK DRAWINGS. PROVIDE SHOP DRAWINGS TO DESIGNER PRIOR TO CONSTRUCTION.EQUIPMENT40. TYPE II HOOD, PROOFER OVEN: BY OWNER. SEE EQUIPMENT PLAN FOR LOCATION AND EQUIPMENT SCHEDULE.41. WALK-IN COOLER: BY OWNER. GC TO PROVIDE CONDENSCENT LINES TO FLOOR DRAIN. PROVIDE ELECTRICAL. GC TO INSTALL PER MFRS SPECIFICATIONS. SEE EQUIPMENT PLAN FOR LOCATION AND EQUIPMENT SCHEDULE. 42. WALK-IN FREEZER: BY OWNER. GC TO PROVIDE CONDENSCENT LINES TO FLOOR DRAIN. PROVIDE ELECTRICAL. GC TO INSTALL PER MFRS SPECIFICATIONS.PREFAB UNIT TO BE PROVIDED. SEE EQUIPMENT PLAN FOR LOCATION AND EQUIPMENT SCHEDULE.43. CLOSURE PANEL @ WALK-IN: SEE REFLECTED CEILING PLAN. 44. CLOSURE PANEL @ TYPE II HOOD: SEE REFLECTED CEILING PLAN.PLUMBING – ALL ITEMS LISTED, REFER TO PLUMBING DRAWINGS50. WATER SERVICE/METER: VERIFY SIZE OF SERVICES REQUIRED FOR USE W/ LOCAL JURISDICTION. 51. FOOD, OIL, GREASE INTERCEPTOR: PROVIDE IF REQUIRED BY LOCAL JURISDICTION. 52. WATER HEATER: PROVIDE NSF, SIZED FOR USE. MOUNT ON LEGS 6” AFF. SEE EQUIPMENT PLAN. 53. MOP SINK: PROVIDE. SEE EQUIPMENT PLAN. 54. HANDSINK: PROVIDE. SEE EQUIPMENT PLAN. 55. PREPSINK: PROVIDE. SEE EQUIPMENT PLAN. 56. 3 COMPARTMENT SINK W/ DRAINBOARDS: PROVIDE. SEE EQUIPMENT PLAN. 57. FLOOR DRAIN: PROVIDE AT VARIOUS LOCATIONS. SEE FLOOR FINISH PLAN FOR LOCATION.58. FLOOR SINK: PROVIDE AT SODA STATION (CUSTOMER AND DRIVE THRU) AND POS COLD ICE PAN. SEE FLOOR FINISH PLAN FOR LOCATION. 59. TOILET ROOM FIXTURES: PROVIDE ADA ELONGATED FLOOR MOUNTED TOILET AND WALL MOUNTED HAND SINK & FAUCET. SEE 3/A1 FOR ACCESSIBLE MOUNTING INFORMATION.ELECTRICAL – ALL ITEMS LISTED, REFER TO ELECTRICAL DRAWINGS60. ELECTRICAL PANEL: RELOCATE PANEL TO NEW LOCATION. CONTRACTOR SHALL VERIFY POWER REQUIRMENTS FOR SPACES AND EQUIPMENT. MECHANICAL – ALL ITEMS LISTED, REFER TO MECHANICAL DRAWINGS70. TYPE II HOOD EXHAUST FAN, INLINE: EXHAUST SHALL BE LOCATED THROUGH REAR WALL OF SPACE ABOVE WALK-IN FREEZER, AS PER LOCAL ZONING ORDINANCE RESTRICTION.71. HVAC SYSTEMS: SHALL BE MOUNTED IN CEILING PLENUM TOWARDS REAR OF SPACE. HVAC CONTRACTOR SHALL COORDINATE SIZE, PLACEMENT AND CLEARANCE FOR UNITS INSTALLED WITH SPACE PROVIDED PRIOR TO FRAMING THIS ROOM. DESIGN INTENT IS FOR EQUIPMENT TO BE INSTALLED TO MINIMIZE DISRUPTION TO FACILITY DURING TIMES OF MAINTAINANCE FILTER REPLACEMENT.FIRE SUPPRESSION & ALARM80. FIRE SUPPRESSION: NOT INSTALLED THIS TENANT SPACE. NO WORK PROPOSED FOR TENANT IMPROVEMENT. 81. FIRE ALARM: NO CENTRAL SYSTEM INSTALLED THIS TENANT SPACE. NO WORK PROPOSED FOR TENANT IMPROVEMENT.ACCESSIBLE CLEARANCES90. DOOR APPROACH FROM FRONT / PUSH SIDE. OFFSET 0” FROM LATCH SIDE AND 48” FROM FACE OF DOOR OPENING. 91. DOOR APPROACH FROM FRONT / PUSH SIDE, HAVING BOTH CLOSURE & LATCH. OFFSET 12” FROM LATCH AND 48” FROM FACE OF DOOR OPENING.92. DOOR APPROACH FROM FRONT / PULL SIDE, HAVING BOTH CLOSURE & LATCH. OFFSET 18” FROM LATCH AND 60” FROM FACE OF DOOR OPENING.93. DOOR APPROACH FROM SIDE/ PUSH SIDE. OFFSET 22” FROM HINGE AND 42” FROM FACE OF DOOR OPENING.94. DOOR APPROACH FROM SIDE/ PUSH SIDE, HAVING BOTH A CLOSURE & LATCH. OFFSET 22” FROM HINGE AND 48” FROM FACE OF DOOR OPENING.95. DOOR APPROACH FROM SIDE / PUSH SIDE. OFFSET 24” FROM LATCH AND 42” FROM FACE OF DOOR OPENING.96. DOOR APPROACH FROM SIDE / PUSH SIDE, HAVING BOTH CLOSURE & LATCH. OFFSET 24” FROM LATCH AND 48” FROM FACE OF DOOR OPENING.97. TURNING CIRCLE 60” 98. LAVATORY - OR - MANEUVERING CLEARANCE PAST DOOR SWING CLEARANCE: 30” X 48.99. WATER CLOSET CLEAR FLOOR SPACE CLEARANCE: 60” WIDTH X 56” DEPTH OF TOILET.ACCESSIBLE FIXTURE AND ACCESSORY LOCATION INFORMATIONA.SINK, WALL MOUNTED. LOCATE A MIN OF 15” OR MORE FROM SIDE WALL AND MOUNTED SO TOP OF SINK IS MAX 34” AFF AND UNDERSIDE IS MIN OF 27” AFF, AS DIMENSIONED.B.SOAP DISPENSER. LOCATE 5” FROM FRONT FACE OF SINK AND 42” AFF, AS DIMENSIONED.C.PAPER TOWEL DISPENSER. LOCATE 5” FROM FRONT FACE OF SINK AND 42” AFF, AS DIMENSIONED.D.MIRROR. WALL MOUNTED CENTERED ABOVE SINK. LOCATE SO BOTTOM OF REFLECTED SURFACE 40” AFF.E.TOILET, ACCESSIBLE, FLOOR MOUNT, ELONGATED BOWL. LOCATED 16”-18” FROM SIDEWALL, AS DIMENSIONED.F.HORIZONTAL GRAB BAR, 42” LONG. MOUNTED TO SIDE OF TOILET. LOCATED 12” FROM REAR WALL, AND TOP OF BAR AT 33”-36” AFF. AS DIMENSIONED.G.HORIZONTAL GRAB BAR, 36” LONG. MOUNTED BEHIND TOILET. LOCATED 12” FROM CENTER OF TOILET, AND TOP OF BAR AT 33”-36” AFF., AS DIMENSIONED.H.HORIZONTAL GRAB BAR, 24” LONG, MOUNTED BEHIND TOILET. LOCATED 12” FROM CENTER OF TOILET, AND TOP OF BAR AT 33”-36”AFF., AS DIMENSIONED.I.VERTICAL GRAB BAR, 18” LONG, MOUNTED TO SIDE OF TOILET. LOCATED FROM 39”-41” AFF REAR WALL AND 39”-41” AFF. AS DIMENSIONED.J.TOILET PAPER DISPSENER. MOUNTED TO SIDE OF TOILET. LOCATED IN AN AREA MEASURED 24” TO 42” FROM REAR WALL AND 18” TO 1 1/5” BELOW GRAB BAR. AS DIMENSIONED.K.NAPKIN DISPOSAL, WALL MOUNTED, WHERE INSTALLED. MOUNTED TO SIDE OF TOILET. LOCATE TO REAR OF TOILET PAPER DISPENSER, AFTER TOILET PAPER DISPENSER IS LOCATED.L.BABY CHANGING STATION, WALL MOUNTED, WHERE INSTALLED. LOCATE OUTSIDE OF TOILET & DOOR CLEAR SPACE. MOUNT SO WHEN OPENED, TABLE SHALL BE 34” AFF. AS LOCATED ON PLAN.M.ACCESSIBLE ROOM SIGNAGE. WALL MOUNTED TO LATCH SIDE OF DOOR. LOCATED 9” FROM DOOR OPENING MIN OF 48” AFF. SIGNAGE CLEARANCE SHALL BE 18” CENTERED ON SIGN AND 18” FROM FACE OF WALL. AS LOCATED ON PLAN. A-1FLOOR PLAN FLOOR PLAN: MAIN LEVEL 1/4"=1'-0"1FLOOR PLAN NOTES1. VERIFY ALL WORK WITH TENANT PRIOR TO CONSTRUCTION2. SEE EQUIPMENT PLAN FOR ADDITIONAL INFORMATION. INFORMATION IS SHOWN THIS PLAN IS FOR REFERENCE ONLY. 3. SEE PLUMBING, ELECTRICAL AND MECHANICAL ENGINEERED DOCUMENTS ATTACHED FOR ADDITOINAL INFORMATION. INFORMATION IS SHOWN THIS PLAN IS FOR REFERENCE ONLY. 4. PATCH AND REPAIR EXISTING WALLS AS REQUIRED. MAINTAIN ALL RATING SFOR FIRE PARTITIONS, FIRE BARRIERS AND FLOOR/CEILING ASSEMBIES EXISTING.5. FULL HEIGHT WALLS TO HAVE MOVEMENT HEAD TRACK TO ALLOW FOR 1" OF MOVEMENT. DO NOT ATTACH TOP OF STUDS OR GYP. BD. TO MOVEMENT HEAD.6. DIMENSIONS ARE FINISH FACE OF WALL OR OPENING TO FINISH FACE UNLESS NOTED OTHERWISE.7. PROVIDE ADEQUATE BLOCKING, 2X WOODS, FOR FIXTURES, PLUMBING ACCESSORIES, ELECTRICAL PANELS, MILLWORK, GRAB BARS, ETC. PROVIDE 1/2" CDX PLYWOOD BACKING FOR ALL WALL HUNG KITCHEN EQUIPMENT. USE FIRE TREATED WOOD/PLYWOOD IF REQUIRED.8. SPRINKLER SYSTEM: SYSTEM IS NOT REQUIRED. IF EXISTING, SHALL BE MAINTAINED. 9. FIRE ALARM SYSTEM: IF EXISTING, SHALL BE MAINTAINED.10. TYPE II HOODS: PROVIDED AND INSTALLED ABOVE A PROOFING OVEN IN ACCORDANCE WITH IMC 507.2.2 AND 506.4 FOR WHERE COOKING PROCEDURES DOES NOT PRODUCE SMOKE OR GREASE-LADEN VAPORS. ACCORDING TO NPFA 96 4.1.1, THIS HOOD IS EXEMPT FROM STANDARD REQUIRMENTS.FLOOR PLAN KEY NOTES-EXISTING WALL CONSTRUCTION TO REMAIN (NON RATED)EXISTING FIRE BARRIER WALL CONSTRUCTION TO REMAIN.(1 HOUR RATED).EXISTING FIRE PARTITION WALL CONSTRUCTION TO REMAIN.(1 HOUR RATED).INFILL EXISTING OPENING TO MATCH ADJACENT.INTERIOR WALL: 5/8" TYPE X GWB EACH SIDE OF 3-5/8" STEEL STUDS AT 24" OC MAX TO UNDERSIDE OF CEILING.INTERIOR WALL: 5/8" TYPE X GWB EACH SIDE OF 3-5/8" STEEL STUDS AT 16" OC MAX TO UNDERSIDE OF DECK ABOVE.WALL FURRING: 5/8" TYPE X GWB ONE SIDE OF 1-1/2" METAL FURRING CHANNELS TO UNDERSIDE OF CEILING. ALONG EXTERIOR WALLS.WALL FURRING: 5/8" TYPE X GWB EACH SIDE OF 3-5/8" STEEL STUDS AT 24" OC MAX TO UNDERSIDE OF CEILING.PLUMBING WALL: 5/8" TYPE X GWB EACH SIDE OF 5-1/2" STEEL STUDS AT 24" OC MAX TO UNDERSIDE OF CEILING.HOOD WALL: PROVIDE AND SUBSTITUTE 1/2" CEMENT BOARD EACH SIDE OF "W1A" OR INTERIOR FACE OF "EX" OR "W2/W2A" WIDTH AND DEPTH OF HOOD FROM FLOOR TO TOP OF HOOD. NOTE STAINLESS STEEL PANELS TO BE INSTALLED FROM TOP OF QT BASE TO UNDERSIDE OF HOOD ABOVE.WALL TYPESW1W3W2W4INFW2AEXW1ABEVERAGESEATING AREAFREEZERCOOLERSOUPSERVICE COUNTERFOOD PREP 1SLICERSSTORAGECUSTOMERSOVENOFFICEWARE WASHHANDSINKHANDSINKFOOD PREP 2DELIVERYPOSEXEX#101ACCESSIBILITY PLAN: TOILET ROOMS 1/4"=1'-0"24' 0"BIB12B12B14W4172130313439384142515657555754585357PREP WASHACCESSSORY ELEVATIONS: TYPICAL ACCESSIBLE MOUNTING ELEVATIONS 1/4"=1'-0"3TOP =33"-36"39" - 41"1' 6"3' 4"3' 6"1' 0"3' 0"1' 6"40" MIN B.O. REFLECTIVE EDGE1' 6"4' 0"SOAP DISPENSER,OPERATOR HEIGHTPAPER TOWEL DISPENSER,OPERATOR HEIGHT1' 6"1 1/2"1' 0"2' 0"3' 6"BDACEGJFIJGFI6" MIN TOE8" MIN KNEE9" MIN TOE34" MAX27" MIN5"3' 6"3' 6"AM9"STORAGE52431' 9"1' 9"6' 11"6' 11"EXISTING TO REMAIN2"2"2"12' 6"5"18' 8"2"6' 2"EXISTING6' 4"5"6' 6"5"9' 2"5"8' 2"5"CUSTOMERSPOS7"2' 2"4' 1"3' 8"1' 6"10' 6"3' 1"5"2' 9"4"2' 3"5"7' 10"7"3' 2"2' 0"5"4' 5"5"5"2' 8"10' 10"2' 9"12' 0"1' 4"5' 6"70' 6"TOILET9297989998BDAMEG1' 1"1' 7"1' 6"1' 6"1' 6"1' 6"7' 8"6' 6"4' 5"5' 3"9' 0"9898924' 8"5' 0"99979091JFIEGJFICCBDATOILET2A1ELECT60573' 2"ENTRY/EXIT#1009122037119211A11B11C11CEXEX101212A131327151616#10227#10322#1042232333536353630404450545858595970711' 6"(15" MIN)C1929170' 6"E&G TENANT SPACELIMIT OF CONSTRUCTIONE&G TENANT SPACE LIMIT OF CONSTRUCTIONADJ TENANT - N.I.C. ADJ TENANT - N.I.C.DRIVE THRU LANE & PARKING AREALIMITED CONSTRUCTION18' 9"E&G TENANT SPACELIMIT OF CONSTRUCTION EX12EX12EX10EX10EXW1W1W1W2A5757W3W1AW1AW1AW1TOILETTOILETHALLSERVICEPOSBEVERAGEBEAM BEARING DETAILN.T.S.4W8X24 LINTEL, SEE DETAILS 4 & 5/A-1.EXISTING WALL ASSEMBLY:BRICK VENEER W/ AIR SPACE, RIGID INSULATION (*VERIFY), SHEET WEATHER BARRIER (*VERIFY) ON MASONRY BEARING WALL. * MAINTAIN AND TIE INTO ASSEMLBY COMPONENTS WHERE EXIST. FLASHING DETAIL AT OPENINGN.T.S.5MASONRY BEARING WALL, EXISTINGSTEEL LINTEL, W/ STEEL PLATE.NEW WINDOW ASSEMBLYROPE WEAP OR VERTICAL WEEP VENTS EVERY 24"CONTINUOUS METAL FLASHING WITH DRIP. RUN UNDER AND BEHIND BRICK UNDER COUNTER FLASHING.CONTINUOUS BACKER ROD AND SEALANT ALONG JAMB AND HEAD.CONTINUOUS SEALANT ABOUT FRAME ON INTERIORINTERIOR FINISHED OPENINGNOTE: SHORE EXISTING ROOF TRUSSES AS REQUIRED FOR NEW CONSTRUCTION. SHORING DESIGN BY OTHERS.HEAD DETAILJAMB DETAIL: SIM.SILL DETAIL: SIM.WINDOW SET ONTO PAN FLASHING.MAINTAIN DRAINAGE OF WINDOW ASSEMBLY, DO NOT CAULK CLOSE WINDOW WEAPS.WEATHER BARRIER, EXISTING (VERIFY) MAINTAIN AND RUN OVERTOP NEW FLASHING.ADJ TENANT - N.I.C.4' 0"10' 0"701A1.1 1A1.12A1.13 AR11600168PRELIMINARY CONCEPT 1 03.08.2017ERBERT& GERBERT'SSANDWICH SHOPPRINT HISTORY DATEPROJECT:DRAWN:CHECKED:SIGNATURE:REGISTRATION:I hereby certify the this plan was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of INDIANARYAN SCHROEDER17020CBRS102 E. CARMEL DRCARMEL, INDIANAERBERT& GERBERT'SSANDWICH SHOPFINAL CONCEPT 03.16.2017CORPORATE REVIEW 03.31.2017BUILDING / HEALTH REVIEW 04.06.2017HUNTERS QUEST102 E. CARMEL DRIVECARMEL, IN 46033EXPLORATORY EXHIBIT 02.21.2017LANDLORD PRELIM REVIEW 03.28.2017CDR REVISION / REVISION #1 04.26.201711111111 DOOR SCHEDULES - ALL DOOR HARDWARE SPEC TO BE ALLEGION THIS LOCATION- STEEL CRAFT DOORS, SCHLAGE LOCKS, IVES HINGES, LCN CLOSURES, VON DUPRIN EXIT DEVICES A-1.1SCHEDULES&DETAILSDOOR & FRAME TYPEEXISTINGEXIST10"FFGMF / HTC / IG1. EXTERIOR STOREFRONT WINDOW AND DOORS ARE EXISTING TO REMAIN. VERIFY CONDITION.2. F/ H - NEW DOOR W/ HALF LIGHT GLAZING AND EG FILMTC3' 0"6' 8"3' 0"3' 4"2' 0"WINDOW FRAME TYPESF1. EXISTING EXTERIOR WINDOW ARE EXISTING TO REMAIN. VERIFY CONDITION.2. NEW EXTERIOR WINDOW TO MATCH EXISTING. 5' 4"6' 11"6' 8"EXISTINGEXISTTC / IGTC / IGTC / IGDTWALL SECTION: TYPE II HOOD3/8"=1'-0"2WALL SECTION: TYPE II HOOD3/8"=1'-0"114W4404470MASONRY BEARING WALL, EXISTING TO REMAIN.14W440447070EXW1AW1A14W4EXEXEXW1A14W4W1AEX4' 0"SSTFRP-A4' 0"SSTFRP-ATYPE 2 HOOD, PER 507.2.2, HUNG FROM STRUCTURE ABOVEHOOD CLOSURE PANELEXHAUST DUCT SUSPENED FROM STRUCTURE ABOVE REFER TO SHEET A-1 FOR WALL TYPES AND PLAN KEYNOTESREFER TO SHEET A-2 FOR FINISHES.REFER TO M1.1 FOR MECHANICAL INFORMATIONEXHAUST HOOD SUSPENDED FROM STRUCTURE BY THREADED ROD (SEE MFR CUT SHEET) FROM UNISTRUCT INSTALLED PERPENDICULAR TO TRUSSES. ATTACHED ONTO UNDERSIDE OF GYPB CEILING. SECURED BY LEG SCREWS TO A MIN OF 3 TRUSSES. EXISTING GYPSUM CEILING ATTACHED TO UNDERSIDE OF WOOD TRUSS THROUGHOUT. PATCH & REPAIR TO MAINTAIN ASSEMBLY RATINGSTYPE 2 HOOD, HUNG FROM STRUCTURE ABOVEHOOD CLOSURE PANEL REFER TO SHEET A-1 FOR WALL TYPES AND PLAN KEYNOTESREFER TO SHEET A-2 FOR FINISHES.REFER TO M1.1 FOR MECHANICAL INFORMATIONWALL SECTION: TYPE II HOOD3/8"=1'-0"3 REFER TO SHEET A-1 FOR WALL TYPES AND PLAN KEYNOTESREFER TO SHEET A-2 FOR FINISHES.REFER TO M1.1 FOR MECHANICAL INFORMATIONFRP-S10' 0"1MASONRY BEARING WALL, EXISTING TO REMAIN.EXEXHAUST DUCT SUSPENED FROM STRUCTURE ABOVEEXISTING GYPSUM CEILING ATTACHED TO UNDERSIDE OF WOOD TRUSS THROUGHOUT. PATCH & REPAIR TO MAINTAIN ASSEMBLY RATINGS70CARMEL, INDIANA - 03.28.2017DOOR AND FRAME SCHEDULEDOOR NODOORGLASS TYPEFIRE RATING LABELHARDWARE GROUPFRAMENOTESTYPE (1) MATL (3) QTY WIDTH (5) HEIGHT (5) THICK FINISH (4)TYPE (1) MATL (3) FINISH (4)100 EX MTL 1 EX EX - - - - TC - - A1 - - EX - - 1, 2, 3, 6101 EX MTL 1 EX EX - - - - TC - - B - - EX - - 1, 2, 3, 6102 EX MTL 1 EX EX - - - - TC - - - - - - EX - - 1, 2, 3, 7103 F WD 1 3'-0" 6'-8" 1 3/4" PT - - - - C - - HM PT 1, 3, 5, 6104 F WD 1 3'-0" 6'-8" 1 3/4" PT - - - - C - - HM PT 1, 3, 5, 6 DOOR SCHEDULE NOTES1. DOOR TYPE DESIGNATIONEX = EXISTINGFGM = FULL-LITEGLASS METAL, W/ NARROW STILES AND ADA KICKF = FLUSH DOORF/V = FLUSH DOOR W/ 10"X10" VISION PANELF/H = FLUSH DOOR W/ HALF LITE2. GLASS TYPE DESIGNATIONEX = EXISTINGTC = TEMPERED CLEARIG = INSULATED GLAZING TINT, U, SHGC3. MATERIAL MTL = PREFINISHED EITHER HOLLOW METAL OR ALUMINUM HM = HOLLOW METALWD = WOOD4. FINISH - PREFINISHED TO MATCH EXISTING, UNLESS OTHERWISE NOTED "PT" (PT=PAINT)5. WIDTH | HEIGHT - DIMENSIONS PROVIDED APPROXIMATE, FIELD VERIFY6. SIGNAGE7. DRIVE THRU WINDOW - EXISTING TO REMAIN. DOOR HARDWARE GROUPSGROUP A - SEE FLOOR PLAN KEYNOTE #20 A1 - MAIN STOREFRONT ENTRANCE EGRESS HARDWARE: PROVIDE DOOR HARDWARE AS REQUIRED INCLUDING HINGES, PROVIDE PULL HANDLE, DEADLATCH SET W/ DOUBLE KEYED LOCKING CYLINDER (KEYED AS PER OWNER) AND CLOSURE. PROVIDE SIGNAGE “THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED.”A2 - SECONDARY STOREFRONT ENTRANCE EGRESS HARDWARE: PROVIDE DOOR HARDWARE AS REQUIRED INCLUDING HINGES, PROVIDE PULL HANDLE, DEADLATCH SET W/ PANIC BAR RELEASE & DOGGABLE WITH KEYED LOCK (KEYED AS PER OWNER) AND CLOSURE.GROUP B - SEE FLOOR PLAN KEYNOTE #21 HARDWARE GROUP B - SERVICE DOORPROVIDE CLOSURE, HINGES, STORE DOOR LOCKSET W/ LEVER HANDLES AND KICKPLATE EACH SIDE OF DOOR. PROVIDE WITH CONTIOUS DRIP EDGE ALONG HEAD OF DOOR. PROVIDE W/ SECURITY GLASS EYE VIEWER. PROVIDE SIGNAGE “EMPLOYEE ENTRANCE ONLY”GROUP C - SEE FLOOR PLAN KEYNOTE #22 HARDWARE GROUP C - TOILET ROOM DOORPROVIDE CLOSURE, HINGES, PUBLIC RESTROOM LOCKSET AND KICK PLATE EACH SIDE. PROVIDE RESTROOOM SIGNAGE.GROUP D - NOT USED - SEE FLOOR PLAN KEYNOTE #23 HARDWARE GROUP D - EMPLOYEE TRAFFIC DOORPROVIDE CLOSURE, HINGES, PASSAGE SET W/ LEVER HANDLES, KICKPLATE EACH SIDE OF DOOR, AND FLOOR MOUNTED DOOR STOP. PROVIDE EMPLOYEE ONLY SIGNAGE.GROUP E - SEE FLOOR PLAN KEYNOTE #24 HARDWARE GROUP E - OFFICE DOORPROVIDE CLOSURE, HINGES, PRIVACY LOCKSET AND KICK PLATE EACH SIDE.GROUP F - SEE FLOOR PLAN KEYNOTE #25 HARDWARE GROUP F - STOREAGE ROOM DOORPROVIDE CLOSURE, HINGES, STORAGE, LOCKSET AND KICK PLATE EACH SIDE.GROUP G - SEE FLOOR PLAN KEYNOTE #26 HARDWARE GROUP G - EMPLOYEE DOUBLE ACTING SERVICE TRAFFIC DOORPROVIDE DOUBLE ACTING DOOR CLOSURE & HINGE, PUSH PLATES & KICKPLATE EACH SIDE OF DOOR. PROVIDE EMPLOYEE ONLY SIGNAGE WINDOW SCHEDULEWDW NOFRAME ASSEMBLYGLASSTYPEFIRERATINGLABEL GLAZINGNOTESTYPE (1) MATL (3) QTY WIDTH (5) HEIGHT (5) THICK FINISH (4)IG THICK TINTG1 EX EX 2 EX EX - - EX EX - - EX EX EX G2 EX EX 1 EX EX - - EX EX - - EX EX EX G3 SF MTL 1 7'-0" 5'-4" - - - - TC/IG - - LOW-E 1/2" CLEAR 1, 2, 3, 4, 5 WINDOW SCHEDULE NOTES1. WINDOW TYPE DESIGNATIONSF = STOREFRONT ASSEMBLY, W/ NARROW STILES2. GLASS TYPE DESIGNATIONEX = EXISTINGTC = TEMPERED CLEARIG = INSULATED GLAZING: TINT COLOR TO MATCH EXISTING, U-FACTOR 0.45 MAX, SHGC 0.40 MAX3. MATERIAL MTL = PREFINISHED EITHER HOLLOW METAL OR ALUMINUM 4. FINISH - PREFINISHED TO MATCH EXISTING5. WIDTH | HEIGHT - DIMENSIONS PROVIDED APPROXIMATE, FIELD VERIFYAR11600168PRELIMINARY CONCEPT 1 03.08.2017ERBERT& GERBERT'SSANDWICH SHOPPRINT HISTORY DATEPROJECT:DRAWN:CHECKED:SIGNATURE:REGISTRATION:I hereby certify the this plan was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of INDIANARYAN SCHROEDER17020CBRS102 E. CARMEL DRCARMEL, INDIANAERBERT& GERBERT'SSANDWICH SHOPFINAL CONCEPT 03.16.2017CORPORATE REVIEW 03.31.2017BUILDING / HEALTH REVIEW 04.06.2017HUNTERS QUEST102 E. CARMEL DRIVECARMEL, IN 46033EXPLORATORY EXHIBIT 02.21.2017LANDLORD PRELIM REVIEW 03.28.2017CDR REVISION / REVISION #1 04.26.201711 1" SANALITE (BLACK)SMOOTH3' 9"6"2' 9"6"1"1/2"1"1/2"1/4"GALVANIZED METAL J TRIM 1" X 3/4" X 1/2"ATTACH METAL TO WALL WITH GALVANIZED SCREWS AT 48" MAX.OVERLAP ENDS AS REQUIRED AND SCREW TO STUDS.1" SANALITE (BLACK)SMOOTHCORRUGATED METAL SHEET 3/4" THICK X 33" HIGH, GALVANIZED FINISH.GALVANIZED METAL J TRIM 1" X 3/4" X 1/2"LEAVE GAP TO FLOOR FOR SEALANT (BLACK)A-2SEE ELEVATIONSFOR MOUNTINGHEIGHTGC TO VERIFY SIZE AND LOCATIONS WITH E/G CORPORATE.PROVIDE ELECTRICAL AND BLOCKING.GC TO PROVIDE AND INSTALL GALVANIZED PANEL WITH ROLLED EDGES "CAST OF CHARACTERS" GRAPHIC SUPPLIED AND INSTALLED BY SIGN VENDOR COORDINATED BY E/G. "BOYS" GRAPHIC SUPPLIED AND INSTALLED BY SIGN VENDOR COORDINATED BY E/G.FINISH PLAN NOTES1. SEE FINISH SCHEDULE FOR TYPICAL FINISHES AND COLORS ETC.2. PROVIDE STAINLESS STEEL CORNER GUARDS AT EXPOSED CORNERS FROM TOP OF BASE TO 6'-0" AFF. 1. COOLER, FLOOR IS TO BE QT, BASE TO BE PROVIDED BY MANUFACTURER.2. TAPE AND PAINT ONLY BEHIND WALK-IN COOLER AND OR FREEZER. WHITE.3. MOP SINK, FLOOR MOUNTED.4. FLOOR SINK.5. FLOOR DRAIN.6. TRANSITION FROM CT-3 TO QT-1 AT POS/MAKETABLE. INTENT TO FOLLOW ALONG BACK FACE OF MILLWORK KICKPLATE TYPICAL.7. GC TO PROVIDE BOTH SS TRIM CLOSURE BETWEEN WALK-IN COOLER / FREEZER FROM FLOOR TO CEILING AND CLOSURE PANEL ABOVE UNIT TO UNDERSIDE OF CEILING ABOVE.8. PRIVACY FILM: EG GRAPHIC / WINDOW FILM SHALL BE INSTALLED ON GLAZING ADJOINING HIGH TOP & HIGH COUNTER LOCATIONS. SEE SHEET A4 FOR LOCATION.9. POS SOFFIT: MILLWORK SUSPENDED SOFFIT ABOVE. SEE A-3 REFLECTED CEILNG PLAN.FINISH PLAN KEYNOTESE/G COMMUNITY BOARD SUPPLIED AND INSTALLED BY SIGN VENDOR COORDINATED BY E/G.-FINISH PLAN, FLOOR AND WALL: MAIN LEVEL 1/4"=1'-0"2GC TO PROVIDE AND INSTALL GALVANIZED PANEL WITH ROLLED EDGES FOR "PILLAR SIGN(S)" GRAPHIC SUPPLIED AND INSTALLED BY SIGN VENDOR COORDINATED BY E/G.1' 4"2' 7"3' 7"1' 6"3' 0"6' 1"GC TO PROVIDE AND INSTALL GALVANIZED PANEL WITH ROLLED EDGES "WELCOME" GRAPHIC SUPPLIED AND INSTALLED BY SIGN VENDOR COORDINATED BY E/G.80% MENU BOARDS for Carmel, IndianaSIGNAGE 1/2"=1'-0"1GC TO PROVIDE AND INSTALL GALVANIZED PANEL WITH ROLLED EDGES FOR "LIVE FLAVORFULLY", "LET'S SPOON", AND "FLAVOR LIKE WHOA" GRAPHIC SUPPLIED AND INSTALLED BY SIGN VENDOR COORDINATED BY E/G.2' 10"2' 10"2' 10"FINISH PLANANDGRAPHICSDINING ROOM WAINSCOTINGNO SCALE32' 10"2' 10"3' 4"7' 8"3' 4"4' 2"2' 10"1' 4"1' 4"QT-11' 10"8"1' 10"1' 0"3' 3"9' 8"2' 10"11' 6"1' 3"3' 6"7' 2"1' 3"1' 2"10"3' 9"1' 2"FB-1, WC-1, CR-1, PT-1FB-1, WC-1, CR-1, FRP-FB-1, WC-1, CR-1, PT-1QT-1QT-1QT-1SST4' 0"4' 0"FRP-SFRP-SFRP-S5CT-1CT-2CT-1PT-4PT-555CT-1CT-2PT-4CT-1CT-3PT-5555444CT-312766889FRP-AFRP-AFRP-A9INTERIOR FINISH SCHEDULECarmel, IN 03.27.2017CODEFINISH TO BE USED AT THIS LOCATION IS MARKED WITH AN (X) MATERIAL MANF.DESCRIPTION OR SERIES COLORDIMENSIONS ADDITIONAL INFORMATIONACT-1 X 2'X4' VINYL CEILING TILE (WASHABLE) USGSHEET ROCK CLIMAPLUS # 3270TILE: WHITE GRID 24" X 48" X 5/8" THICK. GRID IS 15/16" THICK OR EQUALACT-2 X 2'X2' ACCOUSTIC CEILING TILE USGFROST CLIMAPLUS#414.205TILE: BLACK GRID BLACK 24" X 24" X 5/8" THICK. GRID IS 15/16" THICKPROVIDE BLACK TILE AND GRID OR OR PAINT TILE AND GRID PT-6. ACT-3 X 2'X2' VINYL CEILING TILE (WASHABLE) USGSHEET ROCK CLIMAPLUS # 3270TILE: WHITE GRID 24" X 24" X 5/8" THICK. GRID IS 15/16" THICKOR EQUAL. PAINT TILE & GRID TO MATCH EITHER PT-6 (BLACK) OR PT-7 (RED)ACT-4 X 2'X2' ACCOUSTIC CEILING TILE USG FROST TILE: WHITE GRID WHITE 24" X 24" X 5/8" THICK. GRID IS 15/16" THICK PROVIDE WHITE TILE AND WHITE GRID.ACT-5 X 2'X4' ACCOUSTIC CEILING TILE USG FROST TILE: WHITE GRID WHITE 24" X 48" X 5/8" THICK. GRID IS 15/16" THICK PROVIDE WHITE TILE AND WHITE GRID.GWB-1 X GYPSUM WALL BOARD CEILING USG - PER PLAN5/8" GWB. USE TYPE X IF REQUIRED.-CM-1 CROWN MOULDING - - BLACK1 X 3 FLAT SANALITE REFER TO INTERIOR ELEVATIONS FOR HEIGHTCR-1 X CHAIR RAIL - - BLACK1 X 6 FLAT SANALITE REFER TO INTERIOR ELEVATIONS FOR HEIGHTWC-1 X CORRUGATED GALVANIZED METAL - 2-1/2" RIBBED FACTORY- SEE DETAIL ON FINISH PLANFB-1 X FLOOR BASE - - 1 X 6 SANALITE REFER TO INTERIOR ELEVATIONS FOR HEIGHTQT-1 X QUARRY TILE DAL-TILEQUARRY TILE WITH COVE BASE#QT01 RED. FINISH: SEALER. GROUT: MAPEI DARK BROWN6" X 6" QT WITH 6" HIGH BASE CONTACT: DAL-TILE. TOM PALMER 651.214.8078. COVE BASE AT WALLSFRP-A X ARTIZAN FRP MARLITE STONE GRID PATTERN #1810G1212 DUSK -CONTACT: MARLITE. KAREN KANE, 330-260-7617 EMAIL: kkane@marlite.com. INCLUDE ALL NECESSARY ADHESIVE AND TRIMSFRP-S X STANDARD FRP MARLITE PEBBLED SURFACE #140 IVORY -CONTACT: MARLITE. KAREN KANE, 330-260-7617 EMAIL: kkane@marlite.com. INCLUDE ALL NECESSARY ADHESIVE AND TRIMSPT-1 X WALL PAINTSHERWIN WILLIAMSFINISH: SATIN #SW 0012, EMPIRE GOLD -WALLSPT-2 X WALL PAINTSHERWIN WILLIAMSFINISH: SATIN #SW 6990, CAVIAR -WOOD BASE, CHAIR RAIL, VERTICALS, TRIM, AND WALLSPT-3 WALL PAINTSHERWIN WILLIAMSFINISH: SATIN #SW 6871, POSITIVE RED -BULKHEADPT-4 X WALL AND CEILING PAINTSHERWIN WILLIAMSFINISH: SATIN #SW 6387, COMPATABLE CREAM -RESTROOM WALLS AND CEILINGPT-5 X WALL PAINTSHERWIN WILLIAMSFINISH: SATIN #SW 6990, CAVIAR -DOOR, DOOR TRIM, WINDOW, WINDOW TRIMPT-6 X CEILING PAINTSHERWIN WILLIAMSFINISH: FLAT #SW 6990, CAVIAR -ALL GRID, TILES, SPEAKERS, OR EXPOSED CEILING AND STRUCTURE ETCPT-7 X CEILING PAINTSHERWIN WILLIAMSFINISH: FLAT #SW 6871, POSITIVE RED -ALL GRID, TILES, SPEAKERS, OR EXPOSED CEILING AND STRUCTURE ETCPT-8 X CEILING PAINTSHERWIN WILLIAMSFINISH: FLAT WHITE-BULKHEAD AND CEILING, COLOR TO MATCH ACT 1.LAM-1 X PLASTIC LAMINATE WILSONART - #4623, GRAPHITE NEBULA -COUNTER TOPS, TABLE TOPS, LAM-2 X PLASTIC LAMINATE WILSONART - #1595-60, BLACK -MILLWORK, WINDOW SILLSLAM-3 X PLASTIC LAMINATE WILSONART -#4779-60 PEWTER BRUSH WITH BLACK PVC EDGE-DINING TABLE TOPSLAM-4 X PLASTIC LAMINATE FORMICA - #839-58 STOP RED -POS BULKHEAD/SOFFIT TRIM. MILLWORK SUSPENDED SOFFIT, SEE MILLWORK DETAIL SHEETCT-1 X CERAMIC TILE DAL-TILEPATTERN: CITY VIEW NEIGHBORHOOD PARK#07. GROUT: CHOCOLATE12" X 12" CERAMIC TILE WITH 6" HIGH MATCHING COVE BASERESTROOM FLOORS 'CONTACT: DAL-TILE. TOM PALMER 651.214.8078.CT-2 X CERAMIC TILE DAL-TILEPATTERN: CITY VIEW NEIGHBORHOOD PARK#07. GROUT: CHOCOLATE 12" X 12" CERAMIC TILE TO 48" AFF. RESTROOM WALLS. 'CONTACT: DAL-TILE. TOM PALMER 651.214.8078.CT-3 X CERAMIC TILE DAL-TILE VERANDA SOLIDS #SUEDE P24. #07. GROUT: CHOCOLATE13" X 13" CERAMIC TILE WITH 6" HIGH BASE AT AREA SHOWN ON FINISH PLAN. PROVIDE ALTERNATE PRICE FOR 20"X20" TILE.DINING, CUSTOMER, HALLWAYS. 'CONTACT: DAL-TILE. TOM PALMER 651.214.8078.CT-4 X CERAMIC TILE - BLACK #SUEDE P24. #07. GROUT: CHOCOLATE6" HIGH COVE BASE INSTALL BEHIND SODA COUNTER ONLYBEHIND DINING ROOM SODA STATION ONLYSST X STAINLESS STEEL - SHEET MATERIAL STAINLESS ALL WALLS SURROUNDING THE HOOD SUPPLIED BY KITCHEN EQUIPMENT SUPPLIER. INSTALLED BY GC. VERIFY.CG X CORNER GUARDS. - PRE FABICATED STAINLESS 1-1/2" X 1-1/2" X FULL HEIGHT SUPPLIED AND INSTALLED BY GC. SC X SEALED CONCRETE - - --SUPPLIED AND INSTALLED BY GC. AR11600168PRELIMINARY CONCEPT 1 03.08.2017ERBERT& GERBERT'SSANDWICH SHOPPRINT HISTORY DATEPROJECT:DRAWN:CHECKED:SIGNATURE:REGISTRATION:I hereby certify the this plan was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of INDIANARYAN SCHROEDER17020CBRS102 E. CARMEL DRCARMEL, INDIANAERBERT& GERBERT'SSANDWICH SHOPFINAL CONCEPT 03.16.2017CORPORATE REVIEW 03.31.2017BUILDING / HEALTH REVIEW 04.06.2017HUNTERS QUEST102 E. CARMEL DRIVECARMEL, IN 46033EXPLORATORY EXHIBIT 02.21.2017LANDLORD PRELIM REVIEW 03.28.2017CDR REVISION / REVISION #1 04.26.2017 PROVIDE EITHER 2 X6 OR UNISTRUT CONTINUOUS ABOVE CEILING FOR MENU SUPPORTNOTE: GC TO PROVIDE FLANGESMENU BOARD ATTACHMENTNO SCALE3MAKE TABLEEACH MAKE TABLE (2), PROVIDE HOME RUN CONNECTIONS FOR PRINTER (1) PRINTER CABLE FROM POS TO OFFICE. A-3REFLECTED CEILING ANDTECHNOLOGY PLANPOS SYSTEM AT OFFICE.PROVIDE (1) DEDICATED 20 AMP 4 PLEX RECEPTACLE AT 84" AFF. RECEPTACLE PROVIDED BY OTHERSPROVIDE SECURITY CABINET FOR: POS, AMP FOR MUSIC, DATA PATCH PANEL, DATA SWITCH, 66 BLOCK, ROUTER/FIREWALL. SUPPLIED BY LOW VOLTAGE CONTRACTOR.PROVIDE VOICE AND DATA EXTENSION TO DEMARK (2) COAX OR (2) CAT5E DEPENDING ON PROVIDED. 66 BLOCK FOR VOICE STATIONSTECHNOLOGY PLAN 1/8"=1'-0"2POS AT DELIVERY COUNTEREACH POS (2), PROVIDE HOME RUN CONNECTIONS FOR:TERMINAL (IPAD) (2) COMMUNICATION CABLES PER POS, PRINTER (1) PRINTER CABLE PER POS; FROM POS TO OFFICE.ONE CAT 5E AT THIS LOCATION SHALL BE SPLIT INTO 2 VOICE JACKS. VOICE JACK SHALL HAVE (2) PAIR EACH (2 LINES EACH JACK).REFLECTED CEILING KEY PLAN NOTESREFLECTED CEILING PLAN NOTES1 ALL TRACK / PENDANT LIGHTS ARE TO BE DIMMABLE. PROVIDED TO ILLUMINATE DISPLAY SURFACES ONLY.2 ALL LIGHTS TO BE WARM COLORED, 2700K, UNLESS OTHERWISE NOTED.3 ALL LIGHT FIXTURES AND CEILINGS TO BE INSTALLED PER MANUFACTURER'S RECOMMENDATION.4 SWITCHING TO BE DETERMINED BY ELECTRICIAN, REVIEW WITH DESIGNER. LIGHTS IN SEATING AREAS TO BE ON A SEPARATE SWITCH.5 ALL VOLTAGE REQUIREMENTS ARE THE RESPONSIBILITY OF THE ELECTRICIAN INSTALLING THE SPECIFIED LIGHT FIXTURE.6 CONTRACTOR/ INSTALLER IS RESPONSIBLE FOR VERIFYING ALL DIMENSIONS AND NOTIFYING THE DESIGNER OF ANY DISCREPANCIES AS THEY BECOME EVIDENT.7 ALL DIFFUSERS AND SPEAKERS TO BE PAINTED TO MATCH THE CEILING.8 ALL RECESSED LIGHT FIXTURE TRIMS TO BE PAINTED TO MATCH THE CEILING.9 ELECTRICIAN TO SUPPLY AND INSTALL ALL LIGHT FIXTURES AND TRACK ADAPTERS AS REQUIRED.10 PENDANTS OVER TABLES OR COUNTERS TO BE 30" ABOVE THE TALLEST EATING SURFACE. CRITICAL. DO NOT DEVIATE.11 ELECTRICIAN TO VERIFY ALL REQUIRED EXITING LIGHTING AND EMERGENCY LIGHTING TO MEET CURRENT CODES.12 ANY LIGHTS OVER EXPOSED FOOD STORAGE, PREP, OR DISPLAY AREAS TO BE SHIELDED OR SHATTER RESISTANT.13 ELECTRICIAN TO VERIFYAND PROVIDE LUMEN/FOOT CANDLE REQUIREMNTS AS PER FOOD CODE APPLICABLE.14 ALL EXISTING HVAC DIFFUSERS, SPEAKERS, ETC TO REMAIN IF POSSIBLE. PAINT TO MATCH CEILING. VERIFY LOCATION AND FUNCTIONALITY.15 GC TO REVISE EXISTING SPRINKLER SYSTEM AS REQUIRED.TECHNOLOGY SYSTEMS SCHEDULE2 CAT 5E/6 CABLE LOCATIONSYMBOLDESCRIPTION"DEVICE" CABLE LOCATIONSPEAKERWALL MOUNTED SECURITY CABINET.MANUFACTURER: TRIPP LITEMODEL: SRW12US33GACCESS POINTTECHNOLOGY PLAN NOTES1 LOW VOLTAGE INSTALLER TO VERIFY AND COORDINATE ANY NEEDED PERMITS2 PHONE SYSTEM TO BE SUPPLIED BY LOW VOLTAGE CONTRACTOR.3 Data Communication Cable TYPES, CAT5e or CAT6 MAYBE USED. VERIFY IF CABLING INSTALLED IN CONDUIT IS REQUIRED With local BUILDING OFFICIAL AND codes. Where conduit is used, it must be dedicated to the POS system.4 TERMINALS (POS, DELIVERY, DRIVE THRU) PROVIDE TWO COMMUNICATION CABLE HOME RUNS FROM DEVICE TO THE OFFICE COMPUTER LOCATION. CABLES LABELED5 REMOTE PRINTER (MAKE TABLE) PROVIDE A CABLE HOME RUN FROM DEVICE TO OFFICE COMPUTER LOCATION. CABLES LABELED.6 ACCESS POINTS (POS, DELIVERY) PROVIDE A HOME RUN CABLE, LOCATED IN CEILING ABOVE, FROM DEVICE TO OFFICE COMPUTER. CABLES LABELED.7 HOME RUN CABLE LABELING. BOTH ENDS OF CABLE (DEVICE AND OFFICE) SHALL BE LABELED AS TO ITS DESTINATION.8 NETWORK CABLE, OFFICE. REQUIRES A CABLE TERMINATION UNDER THE DESK.9 Communication Cables may not be buried underground unless protected by sealed conduit10 Data Communication Cables may not be spliced. 11 Data Communication Cables may not be run within three feet of power lines, in or out of conduit, that exceed 110 volts. 12 Data Communication Cables may not be run within three feet of neon or fluorescent lighting. 13 Data Communication Cables may not be run within three feet of devices with a rating of from 2 to 15 Amps and not within five feet of devices rated above 15 Amps. 14 Data Communication Cables may not be run within five feet of three phase equipment. 15 Data Communication Cables may not be run parallel with 110 volt power lines. However, they can run perpendicular to 110 volt power lines if the power lines are encased in conduit. 16 Data Communication Cables must enter the user workstation locations through a junction box (double gang). 17 Data Communication Cables must enter the kitchen printer locations through a covered junction box. The pedestal box cover must have a rubber protected opening through which the cable passes. Exposed cabling in this area must be kept to a minimum. Therefore, conduit must be used wherever possible. 18 Data Communication Cables must enter the office Computer location through a covered junction box. The junction box cover must have a rubber protected opening through which the cable passes. 19 Data Communication Cables at user workstation and remote printer locations must be terminated in a wall mount or box mount, UL approved CAT5 RJ-45 jack. 20 Data Communication Cables at office computer location should be terminated in a UL approved CAT5, punch down type Patch Panel. Mounted in the cabinet. 21 The delivery station requires 2 pair of cate5 termination with a wall plate capable of mounting a phone on top for each terminal.22 The office needs to have a wall mount jack with the fax line wired.-POS AT FRONT SERVICE COUNTEREACH POS (2), PROVIDE HOME RUN CONNECTIONS FOR:TERMINAL (IPAD) (2) COMMUNICATION CABLES PER POS, PRINTER (1) PRINTER CABLE PER POS; FROM POS TO OFFICE.1 VOICE SPLIT INTO 2.1 "MENU BOARD" LIGHTING: TRACK LIGHTING: BLACK FIXTURES: BLACK TRACK. BULBS - LED. SURFACE MOUNTED TO UNDERSIDE OF CEILING. CENTER ON MENU BOARD.2 "CAST OF CHARACTERS" LIGHTING: TRACK LIGHTING: BLACK FIXTURES: BLACK TRACK. BULBS - LED. SUSPENDED FROM MONOPOINT MOUNTS BY ROD. TRACK ELEVATION 10’-0” AFF MAX. CENTER ON GRAPHIC.3 "WELCOME" LIGHTING: TRACK LIGHTING: BLACK FIXTURES: BLACK TRACK. BULBS - LED. SUSPENDED FROM MONOPOINT MOUNTS BY ROD. TRACK ELEVATION 10’-0” AFF MAX. CENTER ON GRAPHIC.4 "LIVE FLAVORFULLY" LIGHTING: TRACK LIGHTING: BLACK FIXTURES: BLACK TRACK. BULBS - LED. SUSPENDED FROM MONOPOINT MOUNTS BY ROD. TRACK ELEVATION 10’-0” AFF MAX. CENTER ON GRAPHIC.5 "FLAVOR LIKE WHOA" LIGHTING: TRACK LIGHTING: BLACK FIXTURES: BLACK TRACK. BULBS - LED. SUSPENDED BY ROD FROM MONOPOINT MOUNTS. TRACK ELEVATION 10’-0” AFF MAX. CENTER ON GRAPHIC.6 "LET'S SPOON" LIGHTING: TRACK LIGHTING: BLACK FIXTURES: BLACK TRACK. BULBS - LED. SURFACE MOUNTED TO UNDERSIDE OF CEILING. CENTER ON GRAPHIC.7 STOREFRONT HIGH COUNTER & HIGH TOP & BOOTH TABLE LIGHTING: LIGHTING PENDANTS: HANG FROM BLACK TRACK ADAPTER WITH BLACK CORD. BULB – LED. PROVIDE 2700K, 700 LUMEN. PENDANTS TO BE TO 30" ABOVE TABLES EATING SURFACE. CRITICAL. DO NOT DEVIATE. MOUNTING FOR CEILINGS GREATER THAN 10 FEET SHALL BE SUSPENDED FROM MONO POINTS 30” O.C, ALL FINISHED BLACK. VERIFY LOCATIONS WITH OWNER PRIOR TO INSTALLATION. NOTE THIS LIGHTING NEEDS TO BE VERIFIED.8 DINING ROOM AND HALLWAY LIGHTING IN GWB, TILE & GRID CEILINGS: 6" RECESSED CAN LIGHT: BULB – LED, PROVIDE 2700K, 700 LUMEN, BLACK BAFFLE, AND BLACK TRIM. CENTER IN CEILING TILE U.N.O. VERIFY WITH E AND G CORPORATE.9 SERVICE/CUSTOMER AREA LIGHTING IN GWB, TILE & GRID CEILINGS: 6" RECESSED CAN LIGHT: BULB – LED, PROVIDE 2700K, 700 LUMEN, BLACK BAFFLE, AND BLACK TRIM. CENTER IN CEILING TILE U.N.O. PROVIDE SHIELDED OR SHATTER RESISTANT LENS. VERIFY WITH E AND G CORPORATE.10 BOH OF RECESSED LIGHTING: 2X4 LED TROFFER FIXTURE. PROVIDE 4000K, MEDIUM LUMEN (4600-4900), FLUSH WHITE STEEL FRAME, PATTERN ACRYLIC LENS, FIXED OUTPUT. PROVIDE SHIELDED OR SHATTER RESISTANT LENS.11 RESTROOM SCONCE LIGHTING: 800 LUMEN LAMP VERIFY. 12 RESTROOM RECESSED CAN LIGHTING IN GWB, TILE & GRID CEILINGS: 6" RECESSED CAN LIGHT: BULB – LED, PROVIDE 2700K, 700 LUMEN, WITH ALBALITE GLASS LENS WITH REFLECTOR AND WHITE TRIM. CENTER IN CEILING TILE U.N.O. VERIFY WITH E AND G CORPORATE.13 SHOW OUTLETS: PROVIDE SHOW OUTLETS IN CEILING ABOVE ALL WINDOWS AND EXTERIOR ENTRY DOOR. CENTERLINE AT OPENING.14 COMMUNITY TABLE LIGHTING: LIGHTING PENDANT: FIXTURE BY FARMSTEAD IRONWORKS, CUSTOM ORDER: RUSTIC INDUSTRIAL LIGHTING CHANDELIER: GALVANIZE IRON PIPE CONSTRUCTION (NATURAL), W/ EDISON FILAMENT BULB AND BLACK CAGES FIXTURE DIMENSIONS: OVERALL HEIGHT 45”, FIXTURE LENGTH 37", 5 BULBS. BULB - LED EDISON/FILAMENT TYPE, 400 LUMEN, 2200 TO 2700 KELVIN. PENDANTS TO BE TO 30" ABOVE TABLES EATING SURFACE. CRITICAL. DO NOT DEVIATE. VERIFY LOCATIONS WITH OWNER PRIOR TO INSTALLATION. NOTE THIS LIGHTING NEEDS TO BE VERIFIED.15 EXTERIOR EXIT LIGHT: PROVIDE EXTERIOR EXIT LIGHTING, WITH A 90 MINUTE BACKUP POWER SUPPLY AT ALL EXITS.16 HOOD: GC TO PROVIDE TYPE II HOOD AND MAKE UP AIR, W/ INTEGRAL LIGHT. INSTALL PER MANFACTURES RECOMMENDATIONS. 17 SERVICE COUNTER CEILING: NEW TILE & GRID CEILING. AS PER FINISH SCHEDULE. 18 BEVERAGE LINES: BEVERAGE TO RUN ABOVE CEILING TO BAG IN BOX SYSTEM IN KITCHEN. 19 BOH CEILING: NEW TILE & GRID CEILING. AS PER FINISH SCHEDULE. 20 CUSTOMER AND DINING CEILING: NEW TILE & GRID SYSTEM AS PER FINISH SCHEDULE. 21 NOT USED: CUSTOMER AND DINING CEILING LIGHTING: LIGHTING: TRACK LIGHTING: BLACK FIXTURES: BLACK TRACK. BULBS - LED. SURFACE MOUNTED TO UNDERSIDE OF CEILING..22 TOILET ROOM CEILLING: NEW TILE & GRID CEILING. AS PER FINISH SCHEDULE. 23 HALLWAY CEILING: NEW TILE & GRID CEILING. AS PER FINISH SCHEDULE. 24 WALKIN COOLER CLOSURE: GC SHALL PROVIDE CLOSURE FROM TOP WALK-IN PACKAGE TO UNDERSIDE OF CEILING ABOVE. 25 TYPE II VENT HOOD CLOSURE: EQUIPMENT SHALL PROVIDE WHERE REQUIRED. SHALL BE INCLUDED WITH VENT HOOD PACKAGE. GC ALTERNATE PROVIDE GYP BD BULKHEAD TO UNDERSIDE OF CEILIING IF REQUIRED. PAINT PT-3.26 SOFFIT TO HALL/BOH: PROVIDE GYP BD BULKHEAD AT OPENING. PAINT.27 SERVICE COUNTER SOFFIT: PROVIDE GYP BD BULKHEAD AT OPENING. PAINT.SEE INTERIOR ELEVATIONS.28 WALL SIGNAGE LIGHTING, WALL MOUNTED: EXISTING WALL MOUNTED GOOSENECK, ANGLED LIGHT: EXISTING TO REMAIN. E-CONOLIGHT E-DG1L13UAK. BLACK. LED 3000K. RATED FOR EXTERIOR APPLICATION. SEE ELVATION FOR MOUNTING HEIGHT. VERIFY WITH E AND G CORPORATE.29 ERBERT & GERBERT'S SIGNAGE, WALL MOUNTED: NON ILLUMINATED WALL MOUNTED LETTER SIGNS. PROVIDE POWER CONNECTIONS, AS REQUIRED, FOR SIGNAGE PACKAGED SUBMITTED UNDER SEPARATE PERMIT.30 ERBERT & GERBERT'S AWNING PACKAGE, WALL MOUNTED: CANVAS AWNING OVER FRAME. AWNING PACKAGE AND DESIGN BY OTHERS. 31MECHANICAL EQUIPMENT PLENUM: HVAC AIR HANDLING EQUIPMENT TO BE INSTALLED THIS PLENUM AREA. COORDINATED PLACEMENT OF EQUIPMENT WITH CAPTIVE AIRE EXHAUST HOOD DUCTWORK, AND WALK-IN CONDENSING UNITS.NO CEILING / LIGHTING ABOVE PROOFER HOOD W/ CLOSURE.1620ACT-29'-9"PT-612TOILET ROOMACT-48'-0"PT-4221125"LIVE FLAVORFULLY" TRACK LIGHTING"FLAVOR LIKE WHOA" TRACK LIGHTING"CAST OF CHARACTERS" TRACK LIGHTINGSERVICE COUNTER / CUSTOMER AREARECESSED CAN LIGHTING849NO CEILING / LIGHTING ABOVE WALK-IN COOLER & FREEZER W/ CLOSURE.9ACT-310'-0" +PT-7176MENU BOARD TRACK LIGHTING125"LET'S SPOON" TRACK LIGHTINGKITCHEN, DELIVERY, DRIVE THRU, PREP & WARE WASHINGACT-19'-9"VINYL1019(1) EXT EXIT LIGHT15SOFFIT @ SERVICE COUNTER27MILLWORK9'-2" +/-LAM-4ACCESS POINT MOUNT ABOVE CEILING SERVICE SIE OF SOFFIT.18SOFFIT TO HALL26GWB6'-8"PT-824(1) EXT EXIT LIGHT15COMMUNITY TABLE CHANDELIER148DINING ROOM, TYPICALRECESSED CAN LIGHTING137(5) STOREFRONT HIGH COUNTER PENDANT FIXTURE.3"WELCOME" TRACK LIGHTINGPOS TO BOH26GWB6'-8"PT-8BEVERAGE COUNTER20ACT-312'-0"PT-68SYMBOLDESCRIPTION29EG NON PACKAGED WALL MOUNTED SIGNS. REFLECTED CEILING PLAN: MAIN LEVEL 1/4"=1'-0"128HUNTERS QUESTGOOSE NECK LIGHTING.SERVICE COUNTER / CUSTOMER AREARECESSED CAN LIGHTINGDINING ROOM, CEILING13131' 3"4' 0"4' 1"4' 0"3' 11"1' 3"1' 9"5' 6"1' 9"1' 9"6' 6"2' 8"13' 7"17' 9"23HALLACT-28'-9"PT-688DINING ROOM, TYPICALRECESSED CAN LIGHTING12TOILET ROOM, RECESSED CAN LIGHTINGKITCHEN, OFFICE, UTILITY, STORAGEACT-19'-0"VINYL101910BOH RECESSED LIGHTINGPOS TO BOH26GWB8'-6"PT-830ERBERT & GERBERT'S AWNING PACKAGE7' 4"7' 9"9' 4"8' 10"31MECHANICAL EQUIPMENTPLENUM AREA (AREA DASHED)ELEC. SWITCH, OUTLET, AND PLATE SCHEDULEROOM OUTLET/SWITCH COLOR PLATE COLORKITCHEN AREA AND SERVICE COUNTERALMOND ALMONDCUSTOMER AND DINING WAINSCOTBLACK BRUSHED ALUMINUMCUSTOMER AND DINING WALLS AND CEILINGBLACK BLACKRESTROOMS ALMOND ALMONDAR11600168PRELIMINARY CONCEPT 1 03.08.2017ERBERT& GERBERT'SSANDWICH SHOPPRINT HISTORY DATEPROJECT:DRAWN:CHECKED:SIGNATURE:REGISTRATION:I hereby certify the this plan was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of INDIANARYAN SCHROEDER17020CBRS102 E. CARMEL DRCARMEL, INDIANAERBERT& GERBERT'SSANDWICH SHOPFINAL CONCEPT 03.16.2017CORPORATE REVIEW 03.31.2017BUILDING / HEALTH REVIEW 04.06.2017HUNTERS QUEST102 E. CARMEL DRIVECARMEL, IN 46033EXPLORATORY EXHIBIT 02.21.2017LANDLORD PRELIM REVIEW 03.28.2017CDR REVISION / REVISION #1 04.26.2017 INTERIOR ELEVATION KEY PLANNO SCALEADINING / POS / SERVICE / SODA / HALL 1/4"=1'-0"11210MAKE 2 / DELIVERY / TOILET / HALL 1/4"=1'-0"11ELEC / STORAGE / WARE WASHING / DELIVERY / SLICING / MAKE TABLE / POS / DINING 1/4"=1'-0"3DINING / POS / SOUP / PROOFER / DRIVE THRU / MAKE TABLE 2 / PREP SINK /OFFICE / STORAGE 1/4"=1'-0"4WALK-IN / JANITORIAL / TOILET / HALL / SERVICE / DINING / ENTRY 1/4"=1'-0"5JANITORIAL / BIB / OFFICE 1/4"=1'-0"15PREP / WARE / TOILET 1/4"=1'-0"6TOILET 1/4"=1'-0"7ENTRY / DINING 1/4"=1'-0"10TOILET 1/4"=1'-0"8TOILET 1/4"=1'-0"9TOILET 1/4"=1'-0"12TOILET 1/4"=1'-0"13TOILET 1/4"=1'-0"14POS / SERVICE 1/4"=1'-0"22154536697811141213111311151 GRAPHIC MENU BOARD. SUPPLIED BY "E AND G". INSTALLED BY GC. PROVIDE BRACKETS AND SUPPORTS TO CEILING ABOVE AS REQUIRED. VERIFY2 ARTWORK GRAPHICS, SURFACE MOUNTED. SUPPLIED AND INSTALLED BY "E AND G". VENDOR. INCLUDES: "BOYS".3 TABLES/ BOOTHS/HIGH COUNTER/CHAIRS ETC BY DECOR PROVIDER.4 ARTWORK GRAPHICS, ON GALVANIZED PANEL, ARTWORK SUPPLIED AND INSTALLED BY "E AND G". VENDOR ONTO GALVANIZED PANEL INSTALLED BY GC. PROVIDE GALVANIZED PANEL WITH ROLLED EDGES. INCLUDES "FLAVORFULLY", “WHOA”, "SOUPS ON", "PILLAR SIGN(S)", "CAST OF CHARACTERS" AND "WELCOME"..5 COMMUNITY BOARD, SUPPLIED AND INSTALLED BY "E AND G". VENDOR .6 DELIVERY MAP, SUPPLIED AND INSTALLED BY "E AND G". VENDOR .7 MILLWORK BY DECOR PROVIDER, INCLUDING: POS COUNTER, MAKE TABLE WALL, DELIVERY STATION, SODA STATION AND DINING ROOM TRASH ENCLOSURE. G.C. INSTALLED.8 MILLWORK BY G.C., INCLUDING: WAINSCOT. 1X6 TOP RAIL, GALVANIZED CORRIGATED METAL SIDING, 1X6 BOTTOM TRIM (BASE). ALL TRIMS TO BE PAINTED (PT-2). TERMINATE AT ALL INSIDE/OUTSIDE CORNERS AND ADJACENT TO EQUIPMENT/MILLWORK. SEE “FINISH PLAN AND DETAILS” PAGE FOR DETAIL.9 MILLWORK BY G.C., INCLUDING: OFFICE DESKTOP AND WALL MOUNTED SUPPORTS, (2) WHITE MELAMINE ADJUSTABLE SHELVES AND SUPPORTS. G.C. PROVIDE BLOCKING IN WALL AS REQUIRED. 10 OFFICE STATION INCLUDING: OFFICE DESKTOP, FILE CABINET, SAFE, KEYBOARD, MOUSE, AND POS BOX. PROVIDE BLOCKING IN WALL AS REQUIRED.11 PROVIDE STAINLESS STEEL CHASE SURFACE MOUNTED OR PVC CHASE SET INTO WALL FOR SODA MACHINE SYRUP LINES.12 EMPLOYEE LOCKERS BY DÉCOR PROVIDER.13 PAINT DOOR AND TRIM. PAINT (PT-5).14 GWB BULKHEAD CEILING @ HALL & @ KITCHEN. BOTTOM AS NOTED ON REFLECTED CEILING PLAN AND EXTEND TO UNDERSIDE OF STRUCTURE ABOVE. PAINT UNDERSIDE OF BULKHEAD PT-8.15 GWB BULKHEAD AT PERIMETER OF POS/MAKE TABLE. BOTTOM AS NOTED ON REFLECTED CEILING PLAN. SUPPORTED BY STRUCTURE ABOVE. FINISH UNDERSIDE AND FACE OF BULKHEAD LAM-4, RED.16 OPENING TO BEYOND.17 TYPE II HOOD VENT. INSTALL PER MANF. INSTRUCTIONS. PROVIDE STAINLESS STEEL PANELS WIDTH OF HOOD FROM BOTTOM OF HOOD TO TOP OF BASE ALL SIDES OF WALLS. 18 PROVIDE CLOSURE OR GWB BULKHEAD, AS PER REFLECTED CEILING PLAN, TO CLOSE OFF TOP TYPE II HOOD.19 WALK IN COOLER & FREEZER. PREFAB. ELEVATED BEYOND.20 PROVIDE CLOSURE OR GWB BULKHEAD, AS PER REFLECTED CEILING PLAN, TO CLOSE OFF TOP OF WALKING COOLER AND OR WALKIN FREEZER. ELEVATED BEYOND.21 ELECTRICAL PANEL.22 WATER HEATER, ON 6” LEGS. LOCATED BEHIND THIS ELEVATION.23 MOP SINK.24 STOREFRONT, GLZAING AND GLAZED DOOR. PREFINISHED. EXISTNG TO REMAIN. 25 SERVICE ENTRANCE, NEW DOOR AND FRAME TO MATCH HAY CREEK SHOPS STANDARD TYPE AND FINISH. 26 EMPLOYEE TRAFFIC DOOR, DOUBLE ACTING & SELF CLOSING, DOOR W/ HALF LITE AND FRAME. SEE FLOOR PLAN.27 TRACK LIGHTING FOCUSED ON MENU BOARD. SEE REFLECTED CEILING PLAN.27A TRACK LIGHTING FOCUSED ON WALL GRAPHIC. SEE REFLECTED CEILING PLAN.27B TRACK LIGHTING, SUSPENDED, FOCUSED ON WALL GRAPHIC. SEE REFLECTED CEILING PLAN.28 PENDANDENT LIGHTING LOCATED ABOVE HIGH COUNTER TOP AT WINDOW FRONTAGE OR ABOVE BOOTH TABLE TOPS. SEE REFLECTED CEILING PLAN.29 EG GLAZING GRAPHIC/MODESTY FILM, ONE WAY VISION, TO BE INSTALLED ONTO STOREFRONT AT HIGH COUNTER SEATING. HEIGHT TO MATCH TOP OF COUNTER BACKSPLASH UNLESS OTHERWISE DIRECTED BY EG. 30 EG GLAZING GRAPHIC/PRIVACY FILM, ONE WAY VISION, TO BE INSTALLED ONTO SERVICE DOOR LIGHT. 31 PENDANDENT LIGHTING, DECORATIVE, LOCATED ABOVE HIGH TOP COMMUNITY TABLE. SEE REFLECTED CEILING PLAN.32 FURNACE(S), FLOOR MOUNTED, SEE MECHANICAL PLAN.A-4INTERIOR ELEVATIONSINTERIOR ELEVATION NOTESINTERIOR ELEVATION KEYNOTES1. SEE FINISH PLAN FOR ADDITIONAL INFORMATION.2. SEE KITCHEN EQUIPMENT PLAN FOR ADDITIONAL INFORMATION.3. SEE MILLWORK SHEETS FOR ADDITIONAL INFORMATION.4. ALL MATERIALS AND FINISHES DISTURBED DURING CONSTRUCTION TO BE REPAIRED AND PATCHED TO MATCH EXISTING CONDITIONS.KEYNOTE #1527127A12' 2"TO U.S. GYPSUM DECK3' 2"MECHPLENUM2' 5"MECHPLENUM12' 2"TO U.S. GYPSUM DECK12' 2"TO U.S. GYPSUM DECK2' 5"MECHPLENUM3' 2"MECHPLENUM12' 2"TO U.S. GYPSUM DECK2' 6"8' 0"6' 4"6' 8"3' 9"4' 6"5' 0"2' 0"5' 0"1' 8"5' 0"1' 8"7' 4"5' 6"1' 6"2' 6"6' 4"6' 4"1616161616163' 9"3' 9"7715127A77312882411273' 9"15127A728827441411771014912427A1985143322233720427A47192120141415677313232 332 322813131313QT-1FRP-SQT-1FRP-SCT-1PT-4FB-1PT-1CT-2WC-1CR-1QT-1FRP-SCT-1PT-4FB-1PT-1CT-2WC-1CR-173287QT-1PT-8FB-1PT-1WC-1CR-1FRP-SQT-1FRP-SFB-1PT-1WC-1CR-1FB-1PT-1WC-1CR-1737FB-1PT-1WC-1CR-1FRP-ALAM-4FRP-ALAM-4FB-1PT-1WC-1CR-11617181718FB-1SSSSFRP-AFB-1PT-1QT-1FRP-SCR-1WC-11718AR11600168PRELIMINARY CONCEPT 1 03.08.2017ERBERT& GERBERT'SSANDWICH SHOPPRINT HISTORY DATEPROJECT:DRAWN:CHECKED:SIGNATURE:REGISTRATION:I hereby certify the this plan was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of INDIANARYAN SCHROEDER17020CBRS102 E. CARMEL DRCARMEL, INDIANAERBERT& GERBERT'SSANDWICH SHOPFINAL CONCEPT 03.16.2017CORPORATE REVIEW 03.31.2017BUILDING / HEALTH REVIEW 04.06.2017HUNTERS QUEST102 E. CARMEL DRIVECARMEL, IN 46033EXPLORATORY EXHIBIT 02.21.2017LANDLORD PRELIM REVIEW 03.28.2017CDR REVISION / REVISION #1 04.26.2017 171816EXTERIOR ELEVATION KEY PLANNO SCALEBSIDE ELEVATION 1/4"=1'-0"16SIDE ELEVATION 1/4"=1'-0"17SIDE ELEVATION 1/4"=1'-0"18BUILDING ELEVATION NOTES1. BUILDING ELEVATION ALTERATION IS LIMITED, THIS PROJECT. WORK INVOLVES INSTALLATION OF A NEW WINDOW OPENING ON SIDE WALL OF BUILDING. 2. DESIGN INTENT IS FOR WINDOW OPENING SIZE TO MATCH THAT OF THE FRONT WINDOW.3. DESIGN INTENT FOR THE MASONRY OPENING DETAIL TO MATCH THAT OF THE EXISTING DRIVE THRU WINDOW. 4. DESIGN WILL NOT INCLUDE SOLDIER, STACK OR ARCH COURSING, NOR SHALL IT INCLUDE ANY BRICK OFFSETS. NOR SHALL THE WINDOW BE INSTALLED WITH ANY CROSSHEAD OR ENTABLATURES.5. TENANT SIGNAGE PACKAGE NOT DEPICTED. TENANT SIGNAGE DESIGN BY OTHERS.BUILDING ELEVATION KEY NOTES1. NEW 64" HIGH, 85" WIDE WINDOW OPENING. DESIGN INTENT IS TO MATCH FRONT WINDOW TYPE, MATERIALS AND FINISH. 2. LOCATION OF EXISTING ENTRY.3. LOCATION OF EXISTING ENTRY / SERVICE DOOR / REAR EXIT (NOT ELEVATED) 4. LOCATION OF EXISTING PICK-UP WINDOW.5. LOCATION OF EXISTING FRONT WINDOW OPENING.6. EXISTING FACADE AND FINISHES TO REMAIN7. EXISTING ROOF TO REMAIN, INCLUDING DOWNSPOUTS AND GUTTERS, ARE NOT DEPICTED.8. EXISTING WALL MOUNTED LIGHT FIXTURE TO REMAIN.9. MODESTY PANEL WINDOW FILM, INSTALLED ON GLAZING AT/ALONG HIGH COUNTER SEATING. SEE FS-1 EQUIPMENT PLAN. 10. ERBERT AND GERBERT WALL SIGNAGE, BY SEPARATE PERMIT.11. ERBERT AND GERBERT WALL MOUNTED CANVAS AWNING W/ SIGNAGE. BY SEPARATE PERMIT.12. SAW CUT VERTICAL CONTROL JOINT INTO EXISTING BRICK. SILL, FROM CORNER TO GRADE. HEAD, FROM LINTEL BEARING TO TOP OF BRICK VENEER. INSERT BACKROD & SEALANT. SEALANT COLOR TO MATCH GROUT.13. MAINTAIN EXISTING WALL ASSEMBLY: BRICK VENEER W/ AIR SPACE, RIGID INSULATION (*VERIFY), SHEET WEATHER BARRIER (*VERIFY) ON MASONRY BEARING WALL. *MAINTAIN AND TIE INTO ASSEMBLY COMPONENTS WHERE EXIST.14. INSTALL FLASHING AT HEAD, AND SILL OF OPENING. INSTALL BACKER ROD & SEALANT ABOUT OPENING, BUT SO NOT TO OBSTRUCT DRAINAGE OF WINDOW ASSEMBLY.15. EXHAUST VENT COVER FOR TYPE II HOOD. KEYNOTE #A-4.1INTERIOR ELEVATIONS7' 0"EXISTING5' 4"EXISTING7' 0"PROPOSED5' 4"PROPOSED96118614611369658' 0"3' 0"3' 5"5"11117761175528108' 0"1' 4"EXISTING1' 4"EXISTING1213141515AR11600168PRELIMINARY CONCEPT 1 03.08.2017ERBERT& GERBERT'SSANDWICH SHOPPRINT HISTORY DATEPROJECT:DRAWN:CHECKED:SIGNATURE:REGISTRATION:I hereby certify the this plan was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of INDIANARYAN SCHROEDER17020CBRS102 E. CARMEL DRCARMEL, INDIANAERBERT& GERBERT'SSANDWICH SHOPFINAL CONCEPT 03.16.2017CORPORATE REVIEW 03.31.2017BUILDING / HEALTH REVIEW 04.06.2017HUNTERS QUEST102 E. CARMEL DRIVECARMEL, IN 46033EXPLORATORY EXHIBIT 02.21.2017LANDLORD PRELIM REVIEW 03.28.2017CDR REVISION / REVISION #1 04.26.20171111 3' 1"A-5MILLWORKSOFFIT DETAIL: SERVICE COUNTERNO SCALE10ACT CEILING ASSEMBLY.SERVICE COUNTER: PLAN 1/2"=1'-0"5MAKE TABLE WALL: SIDE ELEVATION 1/2"=1'-0"8SERVICE COUNTER: BACK ELEVATION 1/2"=1'-0"6SERVICE COUNTER MODEL VIEWSNONE1SERVICE COUNTER: FRONT ELEVATION 1/2"=1'-0"7SERVICE COUNTER: SIDE ELEVATION 1/2"=1'-0"9SERVICE COUNTER: COUNTERTOP PLAN 1/2"=1'-0"5AART WORK SUPPLIED AND INSTALLED BY SIGN VENDOR COORDINATED BY E/G.2-1/2" HOLES WITH RINGS67HOLES WITH RINGS FOR CUP DISPENSERS. VERIFY SIZE.EACH POS (2), PROVIDE:(2) TERMINAL (IPAD), (1) DATA (PRINTER), (1) 2 PLEX POWER OUTLET (IPAD) AND (1) 4 PLEX POWER OUTLETCOUNTERTOPWILSONART 4623-60GRAPHITE NEBULA26 GAUGE GALVANIZED SHEET METAL G-90SEE MODEL VIEWS FOR MATERIALS TYPICALPOSOPENOPENCHIPSCHIPSCLIP ON TOEKICK W/ WILSONART 1595-60 BLACK SERVING COUNTERCHIPS2OPENOPENOPENOPENMAKE TABLE WALLSERVING COUNTERSERVING COUNTERPOSCUT OUT FOR COLD PANSERVING COUNTERMAKE TABLE WALLCHIPSPOSMAKE TABLE WALLOPENOPENOPENOPENOPENMAKE TABLE WALLCOUNTERTOPWILSONART 4623-60GRAPHITE NEBULAACCESS PANELSSNEEZE GUARD VERIFY HEIGHTSERVING COUNTERMAKE TABLE WALLINTERIORWILSONART 1595-60 BLACK WITH BLACK VINYL EDGES.6" SS LEGS1/2" TEMPERED GLASS9(1) DUPLEX OUTLET12X12ACCESSPANEL12X12ACCESSPANELOPEN OPENMAKE TABLE WALLCHIPSSERVING COUNTERPOS12X12ACCESSPANEL(1) DATA & (1) DUPLEX OUTLETSERVICE COUNTER: SECTION 1/2"=1'-0"4CLIP ON TOEKICK W/ WILSONART 1595-60 BLACK SNEEZE GUARD VERIFY HEIGHTCOUNTERTOPWILSONART 4623-60GRAPHITE NEBULASNEEZE GUARD VERIFY HEIGHT12X12ACCESSPANEL84233"1' 1"3"10' 10"10' 7"3"3"1' 1"4' 4"10' 10"3"8"1' 6"8"1' 7"1' 6"1' 8"2' 10"3' 1"1' 9"5' 8"4' 6"3' 9"12' 0"1' 9"1' 1"10"8"8' 1"2' 9"3' 1/2"1' 9"4' 6"1' 1"1' 4"2' 0"4"8' 9"9 1/2"3' 3"1' 1"3' 3"1' 1"1' 1"4' 4"10' 10"2' 9"5' 8"12' 0"3' 0"2' 7"6' 6"8' 8"2-1/2" HOLES WITH RINGS POS TERMINALSCHIP INSET DISPLAY16" X 24" CUTOUT FOR COLD PANPROVIDE A 6" SS RING TO BE FIELD INSTALLED IN BASE CABINET.POSSERVING COUNTERCHIPS3' 3"CUT OUT FOR COLD PAN6" RING, FIELD INSTALLED2-1/2" HOLES WITH RINGS26 GAUGE GALVANIZED SHEET METAL G-90CLIP ON TOEKICK W/ WILSONART 1595-60 BLACK 1X3 TRIM ALL EDGES WITH WILSONART 1595-60 BLACK 6" SS LEGS1/2" TEMPERED GLASS1X3 TRIM ALL EDGES WITH WILSONART 1595-60 BLACK INTERIORWILSONART 1595-60 BLACK WITH BLACK VINYL EDGES.6" SS LEGS6"2' 10"2' 4"SERVING COUNTERMAKE TABLE WALLPOSMAKE TABLE WALLSEE MODEL VIEWS FOR MATERIALS TYPICALSEE MODEL VIEWS FOR MATERIALS TYPICALOPENSNEEZE GUARD VERIFY HEIGHTPOS6"3' 8"5' 0"3' 8"5' 0"SERVICE COUNTER: SECTION 1/2"=1'-0"2SERVING COUNTER2' 10"6"1' 0"1' 1"2X2 NOTCH AT SHELVES AND UPRIGHTS TO ALLOW FOR CABLE. TYP. CHIPSPOSPOS/CHIPS: SECTION 1/2"=1'-0"311"2' 0"3' 1"6"2"2"7"10"2' 10"9"9"6"3"12X12ACCESSPANEL(1) DATA & (1) DUPLEX OUTLETSNEEZE GUARD VERIFY HEIGHTMILLWORK NOTES1. PROVIDE MILLWORK SHOP DRAWINGS TO DESIGNER FOR APPROVAL PRIOR TO CONSTRUTION2. NO EXPOSED WOOD WILL BE ALLOWED. ALL WOOD TO BE COVERED WITH PLASTIC LAMINATE TYPE MATERIAL.3. CABINET MATERIAL TO BE MDF CABINET GRADE. 4. ALL DOOR HINGES TO BE PAINO TYPE5. ALL PULLS IF SHOWN ARE TO BE D TYPE STAINLESS STEEL FINISH.SERVICE COUNTER NOTES1. THIS INCLUDES ALL POS COUNTERS, CHIP DISPLAYS, AND OTHER CABINETS2. TOP SHELVES ARE FIXED.3. MIDDLE SHELVES ARE ADJUSTABLE AND MUST BE ABLE TO BE REMOVED.4. ALL SHELVES ARE TO BE CONSTRUCTED 3" SHORT OF FRONT WALL TO ALLOW FOR WIRING ACCESS.5. ALL VERTICAL SUPPORTS ARE TO HAVE 2"X2" NOTCHES AT BOTTOM TO ALLOW FOR WIRING TO PASS ALL THE WAY THRU THE CABINET.6. ELECTRICAL AND LOW VOLTAGE: (2) FOUR PLEX OUTLETS, (2) DUPLEX OUTLETS [IPAD], AND (2) DATA OUTLETS ARE TO BE INSTALLED. SEE ELEVATIONS FOR LOCATIONS. SEE TECHNOLOGY PLAN NOTES.MAKE TABLE WALL NOTES1. ELECTRICAL AND LOW VOLTAGE: (1) DUPLEX OUTLET AND (4) 12" BY 12" [MIN SIZE] ACCESS PANEL TO BE INSTALLED AT LOCATION BEHIND SANDWICH TABLE. SEE ELEVATIONS FOR LOCATIONS. SEE TECHNOLOGY PLAN NOTES.2. ELECTRICAL AND LOW VOLTAGE: (1) DUPLEX OUTLET, 1 DATA OUTLET AND (1) 12" BY 12" [MIN SIZE] ACCESS PANELS TO BE INSTALLED AT LOCATION ON WING WALL NEXT TO SANDWICH TABLE. SEE ELEVATIONS FOR LOCATIONS. SEE TECHNOLOGY PLAN NOTES.DELIVERY COUNTER NOTES1. (3) 2-1/2" HOLES WITH RINGS TO BE PROVIDE THRU COUNTER..2. ELECTRICAL AND LOW VOLTAGE: (2) FOUR PLEX OUTLET, (1) DUPLEX OUTLET (2) DUPLEX DEVICE OUTLETS [IPAD], AND (3) DATA OUTLETS ARE TO BE INSTALLED. SEE ELEVATIONS FOR LOCATIONS. SEE TECHNOLOGY PLAN NOTES.BOH MAKE TABLE WALL NOTES1. ELECTRICAL AND LOW VOLTAGE: (2) DUPLEX OUTLETS AND (1) DATA OUTLET. SEE ELEVATION FOR LOCATION. SEE TECHNOLOGY PLAN NOTES.8' 1"1' 0"8"THREADED ROD, SUSPENDED FROM STRUCTURE ABOVE.ACT CEILING ASSEMBLY.CEILING ANCHOR BLOCKINGMILLWORK SOFFIT CAP, BY MILLWORK SUPPLIER. LAM-4 RED FINISH.SNEEZE GUARD VERIFY HEIGHT3"1' 1"3"MAKE TABLE WALL672932-1/2" HOLES WITH RINGS POS TERMINALSCHIP INSET DISPLAY16" X 24" CUTOUT FOR COLD PANPROVIDE A 6" SS RING TO BE FIELD INSTALLED IN BASE CABINET.11"2' 10"3' 0"AR11600168PRELIMINARY CONCEPT 1 03.08.2017ERBERT& GERBERT'SSANDWICH SHOPPRINT HISTORY DATEPROJECT:DRAWN:CHECKED:SIGNATURE:REGISTRATION:I hereby certify the this plan was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of INDIANARYAN SCHROEDER17020CBRS102 E. CARMEL DRCARMEL, INDIANAERBERT& GERBERT'SSANDWICH SHOPFINAL CONCEPT 03.16.2017CORPORATE REVIEW 03.31.2017BUILDING / HEALTH REVIEW 04.06.2017HUNTERS QUEST102 E. CARMEL DRIVECARMEL, IN 46033EXPLORATORY EXHIBIT 02.21.2017LANDLORD PRELIM REVIEW 03.28.2017CDR REVISION / REVISION #1 04.26.2017 OFFICE 1/2" = 1'-0"2DINING SODA1/2" = 1'-0"3TRASH1/2" = 1'-0"1DELIVERY STATION1/2" = 1'-0"6BOH MAKE TABLE ELEVATION1/2" = 1'-0"5DINING ROOM HIGH COUNTERS1/2" = 1'-0"46" HOLE WITH RING - TRASHA-5.1MILLWORKNOTE: PROVIDE ALL HARDWARE AND SUPPPORTS AS REQUIRED FOR ALL WALL HUNG COUNTERS AND SHELFS. GC. TO PROVIDE BLOCKING IN WALLWHITE MELAMINE ADJUSTABLE SHELVES AND SUPPORTS.PLANSIDEFRONTEXTERIOR AND INTERIORWILSONART 1595-60 BLACKWITH BLACK VINYL EDGES.PROVIDE S.S. D TYPE PULLS.STRAW HOLDER.PLANFRONT6" HOLE WITH RINGSIDECOUNTERTOPWILSONART 4623-60GRAPHITE NEBULASEE MODEL VIEWS FOR MATERIALS TYPICALEXTERIOR AND INTERIORWILSONART 1595-60 BLACKWITH BLACK VINYL EDGESCOUNTERTOPWILSONART 4623-60GRAPHITE NEBULAPLANFRONTBACKSIDE1' 8"1' 8"SEE MODEL VIEWS FOR MATERIALS TYPICALCOUNTERTOPWILSONART 4623-60GRAPHITE NEBULA6" HOLE WITH RING - SODA DRAIN. PROVIDE ADDITIONAL 6" SS RING, FOR BOTTOM, TO BE FIELD INSTALLED.4' 0"3"3' 9"4"5"11"PLANFRONTSIDEEXTERIOR AND INTERIORWILSONART 1595-60 BLACKWITH BLACK VINYL EDGES.(1) DATA OUTLET AND (1) 2 PLEX OUTLETPRINTERSUPPORTS BRACKETS.GC SUPPLY AND INSTALLDELIVER COUNTERDELIVER HOLDING CABINET(3) 2-1/2" HOLES WITH RINGSSEE MODEL VIEWS FOR MATERIALS TYPICALWALL MOUNTED POSSEE MODEL VIEWS FOR MATERIALS TYPICALWALL MOUNTED PHONE(2) POWER BLOCKSOPENEQOPENEQOPENEQOPENEQ1' 5"1' 7"2' 6"5' 0"BACK SPLASHCOUNTERTOPWILSONART 4623-60GRAPHITE NEBULAWALL MOUNTED SECURITY CABINET10"2' 0"10"4"1' 7"5' 8"1' 6"1' 1"11"4"5' 0"1' 5"1' 2"1' 5"10"PRINTER(1) DATA AND (1) DUPLEX OUTLETPRINTER2' 9"2' 10"4"6"1' 6"2' 6"2' 6"(1) DUPLEX OUTLETCOUNTERTOP W/ BACKSPLASHWILSONART 4623-60GRAPHITE NEBULA5' 6"MODELMODELMODEL(S)NOTE: PROVIDE ALL HARDWARE AND SUPPPORTS AS REQUIRED FOR ALL HIGH COUNTERS. GC. TO PROVIDE BLOCKING IN WALL AS REQUIRED.SS WALL SHELF6" HOLE WITH RING - SODA DRAINPROVIDE AN ADDITIONAL 6" SS RING TO BE FIELD INSTALLED IN BOTTOM OF BASE CABINET.6" HOLE WITH RING - TRASH.STRAW HOLDER4"5' 0"2' 7"10"1' 5"6' 0"1' 0"COUNTERTOPWILSONART 4623-60GRAPHITE NEBULADELIVERY HOLDING CABINET.3' 6"BOLT DOWN SUPPORTSWALL MOUNTED SUPPORTSPLAN - COUNTERTOPELEVATION2' 8"4"3' 3"1' 4"8"1' 6"3' 0"WALL MOUNTEDSUPPORTSBOLT DOWN SUPPORTS(1) 4 PLEX OUTLET(1) DATA JACK(1) VOICE, (1) FAX JACKNOTE: PROVIDE PLYWOOD BACKING FOR ALL WALL MOUNTED EQUIPMENTNOTE: ALL CHORDS TO RUN IN CONDUIT IN WALL TO BELOW COUNTER TOPPOS PROVIDE:(2) TERMINAL (IPAD), (1) 2 PLEX POWER OUTLET (IPAD) AND (1) 4 PLEX POWER OUTLETNOTE: ALL CABLING AND CHORDS TO RUN IN CONDUIT IN WALL TO BELOW COUNTER TOPNOTE: PROVIDE PLYWOOD BACKING FOR ALL WALL MOUNTED EQUIPMENTNOTE: PROVIDE PLYWOOD BACKING FOR ALL WALL MOUNTED EQUIPMENTNOTE: ALL CHORDS TO RUN IN CONDUIT IN WALL TO BELOW COUNTER TOPNOTE: ALL CABLING AND CHORDS TO RUN IN CONDUIT IN WALL TO BELOW COUNTER TOPNOTE: PROVIDE PLYWOOD BACKING FOR ALL WALL MOUNTED EQUIPMENTSECTIONPLAN - SUPPORTS3' 6"4"4' 7"4' 6"11' 10"F.V.1' 4"11' 10"F.V.1' 4"9"1' 10"11' 10"F.V.9"9"4' 6"4' 6"9"1' 10"11' 10"F.V.1"1' 3"WALL MOUNTEDSUPPORTSBOLT DOWN SUPPORTSWALL MOUNTEDSUPPORTSBOLT DOWN SUPPORTSBACKSPLASHCOUNTERTOPBACKSPLASHCOUNTERTOPAR11600168PRELIMINARY CONCEPT 1 03.08.2017ERBERT& GERBERT'SSANDWICH SHOPPRINT HISTORY DATEPROJECT:DRAWN:CHECKED:SIGNATURE:REGISTRATION:I hereby certify the this plan was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of INDIANARYAN SCHROEDER17020CBRS102 E. CARMEL DRCARMEL, INDIANAERBERT& GERBERT'SSANDWICH SHOPFINAL CONCEPT 03.16.2017CORPORATE REVIEW 03.31.2017BUILDING / HEALTH REVIEW 04.06.2017HUNTERS QUEST102 E. CARMEL DRIVECARMEL, IN 46033EXPLORATORY EXHIBIT 02.21.2017LANDLORD PRELIM REVIEW 03.28.2017CDR REVISION / REVISION #1 04.26.2017 DRIVE THRU POS COUNTER1/2" = 1'-0"1DRIVE THRU SODA COUNTER1/2" = 1'-0"2A-5.2MILLWORKMODEL(S)MODEL(S)SEE MODEL VIEWS FOR MATERIALS TYPICALSEE MODEL VIEWS FOR MATERIALS TYPICALSECTIONPLANELEVATION ELEVATION4' 1"2' 11"PLANELEVATION ELEVATIONSECTION8"1' 6"1' 4"1' 4"2' 11"6"1' 0"1' 2"4"2' 10"6" HOLES WITH RINGSEXTERIOR/INTERIOR WILSONART 1595-60 BLACK W/ BLACK VINYL EDGES6" SS LEGS2' 9"1' 1"6"1' 0"1' 2"4"2' 10"6" HOLES WITH RINGSCOUNTERTOPWILSONART 4623-60GRAPHITE NEBULAHOLE WITH RINGS FOR CUP DISPENSERS. VERIFY SIZE.6"11"9"6"3' 0"4"1' 6"3' 0"5' 7"2' 0"8"1"3' 0"EXTERIOR/INTERIOR WILSONART 1595-60 BLACK W/ BLACK VINYL EDGES6" SS LEGSCOUNTERTOPWILSONART 4623-60GRAPHITE NEBULA6"11"9"6"3' 0"4"OPENOPENOPENOPENDRIVE THRU BASE STATION(1) DATA AND (1) DUPLEX OUTLETHEADSET HOLDERARM MOUNTED POS. ARM SUPPLIED BY OWNER.PRINTERPROVIDE CONDUIT FROM BASE STATION TO DRIVE THRU EQUIPMENT4' 6"NOTE: ALL CABLING AND CHORDS TO RUN IN CONDUIT IN WALL TO BELOW COUNTER TOPNOTE: PROVIDE PLYWOOD BACKING FOR ALL WALL MOUNTED EQUIPMENTOPENOPENOPEN4"1' 0"7"9"3" HOLES WITH RING2" HOLES WITH RINGS3"AR11600168PRELIMINARY CONCEPT 1 03.08.2017ERBERT& GERBERT'SSANDWICH SHOPPRINT HISTORY DATEPROJECT:DRAWN:CHECKED:SIGNATURE:REGISTRATION:I hereby certify the this plan was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of INDIANARYAN SCHROEDER17020CBRS102 E. CARMEL DRCARMEL, INDIANAERBERT& GERBERT'SSANDWICH SHOPFINAL CONCEPT 03.16.2017CORPORATE REVIEW 03.31.2017BUILDING / HEALTH REVIEW 04.06.2017HUNTERS QUEST102 E. CARMEL DRIVECARMEL, IN 46033EXPLORATORY EXHIBIT 02.21.2017LANDLORD PRELIM REVIEW 03.28.2017CDR REVISION / REVISION #1 04.26.2017 U101(2)(2)(2)U103(2)S112(4)D110U100U102 EQUIPMENT PLAN: MAIN LEVEL 1/4"=1'-0"1U100U105U106(2)(2)K1768P106P104P107O104P100S100S101E100E101E102S114D100D100.1KW3036CSS109 (2)V99S118KW3630HP102P101P103K1824WABOVEK1224K1836WABOVEK1236(2)(2)KW3036CS115S116(2)(2)(2)G101S107O100O102O101O103O105O106S125K100ABOVEK1236KD2024K1836WK1236ABOVEK1836WK1236ABOVED111K101K101EQUIPMENT PLANFS-1EQUIPMENT PLAN NOTES1. VERIFY ALL EQUIPMENT WITH TENANT PRIOR TO CONSTRUCTION2. VERIFY ALL CUP, SOUP DISPENSORS, SMALL WARES ETC. WITH TENANT PRIOR TO CONSTRUCTION.3. PROVIDE ALL BACKING IN WALL FOR ALL WALL MOUNTED EQUIPMENT.4. WORK TABLES, AS LABELED KW####, WORK TOPS TO BE 36" AFF, UNLESS OTHERWISE NOTED.5. WORK TABLES, LABELED KW3060C, WORK TOP TO BE 24" AFF. RESULTING IN TOP OF SOUP WARMERS ELEVATION OF ABOUT 34" AFF.6. WORK TABLES, LABELED KW3036H & KW3036H, WORK TOPS TO OVERHANG BASE BY 6" TO PERMIT PLACEMENTS OF SLIM JIM TRASH CANS BENEATH WORKSURFACE.7. WORK TABLES, AS LABELED KW####C, TO HAVE 5" CASTERS.8. WALK-IN COOLER PROVIDED WITHOUT FLOOR. GC TO PROVIDE FLOORING AND SS COVED BASE.9. WALK-IN FREEZER PROVIDED WITH FLOOR. NO RAMP.10. WALK-IN COOLER &/OR FREEZER. GC TO PROVIDE SS CLOSURE TRIMS AT WALL ENDS.11. WALK-IN COOLER &/OR FREEZER. GC TO PROVIDE CLOSURE PANEL FROM CEILING DOWN TO WALK-IN UNIT(S).K101K1836WK1236ABOVEU100K1836WABOVEK1236(2)(2)5 TIERKS1824G102P108V99V99S102S102.1S102.3S104S105BS124P109S119D105D105.1D106(2)D118D118.1(3)D102(6)D101.AD101.1(2)D101.2(5)D104(10)D105D105.1D106(2)BEVERAGEMENWOMEND110.1D113SEATING AREAFREEZERCOOLERSOUPSERVICE COUNTERFOOD PREP 1SLICERSSTORAGECUSTOMERSOVENOFFICEWARE WASHHANDSINKFOOD PREP 2DELIVERYPOSBIBSTORAGECUSTOMERSPOSELECTENTRY/EXITADJ TENANT - N.I.C.ADJ TENANT - N.I.C.TOILETTOILETHALLSERVICEPOSBEVERAGEPREP WASH5 TIERKS24545 TIERKS14365 TIERKS18485 TIERKS14365 TIERKS1436G102P1084 TIERKS1430R4 TIERKS1430R4 TIERKS1430R4 TIERKS1430RKW3630H4 TIERKS1430R4 TIERKS1430R4 TIERKS1430R4 TIERKS1430RV99V99V99V99S123S102.1S104G104S124P109S119U104U103U110G103U100U102S112S102G100S106(2)(2)U100AR11600168PRELIMINARY CONCEPT 1 03.08.2017ERBERT& GERBERT'SSANDWICH SHOPPRINT HISTORY DATEPROJECT:DRAWN:CHECKED:SIGNATURE:REGISTRATION:I hereby certify the this plan was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of INDIANARYAN SCHROEDER17020CBRS102 E. CARMEL DRCARMEL, INDIANAERBERT& GERBERT'SSANDWICH SHOPFINAL CONCEPT 03.16.2017CORPORATE REVIEW 03.31.2017BUILDING / HEALTH REVIEW 04.06.2017HUNTERS QUEST102 E. CARMEL DRIVECARMEL, IN 46033EXPLORATORY EXHIBIT 02.21.2017LANDLORD PRELIM REVIEW 03.28.2017CDR REVISION / REVISION #1 04.26.2017 FS-2EQUIPMENT SCHEDULEEQUIPMENT SCHEDULE: Carmel, IndianaDATE 04.20.2017 ITEM #EQUIPMENT TO BE USED AT THIS LOCATION IS MARKED WITH AN (X)ITEM DESCRIPTIONMANUFACTURER MODELQTYPLUMBINGELECTGASSUPPLIED BY OWNERSUPPLIED BY GCSUPPLIED BY VENDORINSTALLED BY OWNERINSTALLED BY GCINSTALLED BY VENDOREXISTING EQUIPMENT TO REMAINEXISTING EQUIPMENT TO RELOCATEDEQUIPMENT COMMENTSD: DINING AREA D100 XTRASH RECEPTACLECUSTOM-1 X X PROVIDED BY MILLWORK VENDORD100.1 XTRASH CANCONTINENTAL COMM 1 X XX PROVIDED BY MILLWORK VENDORD101.A XDINING COUNTERCUSTOMVERIFY SIZE - 12'-4" LEGS 1 X XX PROVIDED BY MILLWORK VENDOR. MOUNT AT 3'-6" AFF. D101.B -DINING COUNTERCUSTOMVERIFY SIZE - 10'-0" F.V. - X XX PROVIDED BY MILLWORK VENDOR. MOUNT AT 3'-6" AFF. D101.1 XDINING COUNTER WALL MOUNTED HANGER 2 X XX PROVIDED BY MILLWORK VENDOR. COORDINATE WITH D101.A, D101.BD101.2 XDINING COUNTER BOLT DOWN BASEOAK STREET MFGBDB-4 BAR5 X XX PROVIDED BY MILLWORK VENDOR. COORDINATE WITH D101.A, D101.BD102 XBAR STOOLS HIGHOAK STREET MFGEG BACKLESS BAR STOOL6 X XX PROVIDED BY MILLWORK VENDORD102.1 -BAR STOOLS LOW- - X XX PROVIDED BY MILLWORK VENDORD103 -HIGH TOP DINING TABLE TOPOAK STREET MFGCTM2430-1- X XX PROVIDED BY MILLWORK VENDORD103.1 -HIGH TOP DINING TABLE BASEOAK STREET MFGB2230-BAR- X XX PROVIDED BY MILLWORK VENDORD104 XDINING CHAIRS FOR HIGH TOP TABLESOAK STREET MFGSL230110 X XX PROVIDED BY MILLWORK VENDORD105 XLOW TOP DINING TABLE TOPOAK STREET MFGCTM2430-12 X XX PROVIDED BY MILLWORK VENDORD105.1 XLOW TOP DINING TABLE BASEOAK STREET MFGB22-STD2 X XX PROVIDED BY MILLWORK VENDORD106 XDINING CHAIRS FOR LOW TOP TABLESOAK STREET MFGSL21604 X XX PROVIDED BY MILLWORK VENDORD107 -GATECUSTOM - X XX PROVIDED BY MILLWORK VENDORD108-BOOTHSOAK STREET MFG5200- X XX PROVIDED BY MILLWORK VENDORD109-BOOTH TABLE TOPOAK STREET MFGCTM3042-1- X XX PROVIDED BY MILLWORK VENDORD109.1-BOOTH TABLE BASEOAK STREET MFGB522-STD- X XX PROVIDED BY MILLWORK VENDORD110 XFRONT POS COUNTERCUSTOM-1 X XX PROVIDED BY MILLWORK VENDORD110.1 XEXTENSION FOR FRONT POS COUNTERCUSTOM-1 X XX PROVIDED BY MILLWORK VENDORD111 XCHIP DISPLAYCUSTOM-1 X XX PROVIDED BY MILLWORK VENDORD112-SERVING COUNTERCUSTOM-- X XX PROVIDED BY MILLWORK VENDOR. PROVIDE STAINLESS STEEL TOPD113XMAKE TABLE WALLCUSTOM-1 X XX PROVIDED BY MILLWORK VENDORD114-DIVIDER WALLCUSTOM-- X X SUPPLIED AND INSTALLED BY GCD115-LOW ROUND TOP DINING TABLE TOP-VERIFY SIZE- X XX PROVIDED BY MILLWORK VENDORD115.1-LOW TOP ROUND DINING TABLE BASE-VERIFY SIZE- X XX PROVIDED BY MILLWORK VENDORD116-DINING CHAIRS FOR LOW TOP ROUND TABLESOAK STREET MFGC-316-US-GR3- X XX PROVIDED BY MILLWORK VENDORD117-BANQUETTEOAK STREET MFG-- X XX PROVIDED BY MILLWORK VENDORD118 XHIGH TOP COMMUNITY ROOM TABLE TOPCUSTOMVERIFY SIZE: 30X721 X XX PROVIDED BY MILLWORK VENDOR. 30"X72"D118.1 XHIGH TOP COMMUNITY ROOM TABLE BASECUSTOM-3 X XX PROVIDED BY MILLWORK VENDORD119 -DINING COUNTER, EXTERIOR, GRANITECUSTOM-- X XX PROVIDED BY MILLWORK VENDOR. MOUNT AT 3'-6" AFF. D119.1 -DINING COUNTER BOLT DOWN BASE, EXTERIOROAK STREET MFGBDB-4 BAR - X XX PROVIDED BY MILLWORK VENDOR. MOUNT AT 3'-6" AFF. D120 -HIGH TOP OUTDOOR DINING TABLE TOPOAK STREET MFGOB3030-BAR - X XX PROVIDED BY MILLWORK VENDORD121 -OUTDOOR DINING CHAIRS FOR HIGH TOP TABLESOAK STREET MFGBM-824 - X XX PROVIDED BY MILLWORK VENDORD122 -LOW TOP OUTDOOR DINING TABLE TOPOAK STREET MFGOB3030-STD- X XX PROVIDED BY MILLWORK VENDORD123 -OUTDOOR DINING CHAIRS FOR LOW TOP TABLESOAK STREET MFGCM-824- X XX PROVIDED BY MILLWORK VENDORD124 -UMBRELLA FOR OUTDOOR DINING TABLE--- X XX PROVIDED BY MILLWORK VENDORE: EXHAUST HOOD/FIRE SUPPRESSION E100 X EXHAUST HOODCAPTIVE AIRE 4848-VHB1 X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCE101 X EXHAUST FANCAPTIVE AIRE IN-LINE, THRU WALL1 X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCE102 X S.S. WALL PANELS BELOW EXHAUST HOOD CAPTIVE AIRE -2 X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCE103- VENTLESS HOODGILES PO-VH- X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCG: GENERAL CONTRACTOR ITEMS G100EX DRIVE THRU WINDOW- -1 X X QUIK SERVE MODEL IFSC-4040. GC TO PROVIDE AND INSTALL. G101X WATER HEATER- -1 XX X XPROVIDE ON 6" LEGS. SECURE TO FLOOR. VERIFY NSF.G102 X SOAP AND TOWEL DISPENSERCUSTOM 2 X X PROVIDED BY EGFS. INSTALLED BY GC.G103 X POS CABINET AT DRIVE THRUCUSTOM -1 X X PROVIDED BY MILLWORK VENDORG104 X SODA CABINET AT DRIVE THRUCUSTOM -1 X X PROVIDED BY MILLWORK VENDORG105 - WATER SOFTENER- -- X X X PROVIDE ON 6" LEGS. SECURE TO FLOOR. VERIFY NSF.K: WORK TABLES/SHELVING K100X SNEEZE GUARDCUSTOM -1 X X PROVIDED BY MILLWORK VENDORK101 X LOAF BREAD RACK (FRONT LOADING) LOCKWOOD -3 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCK102- LOAF BREAD RACK (SIDE LOADING) LOCKWOOD -- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCK1224 X SS WALL SHELFJOHN BOOS EWS8-1224-X1 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCK1236 X SS WALL SHELFJOHN BOOS EWS8-1236-X8 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCK1248 - SS WALL SHELFJOHN BOOS EWS8-1248-X- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCK1260- SS WALL SHELFJOHN BOOS EWS8-1260-X- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCK1272- SS WALL SHELFJOHN BOOS EWS8-1272-X- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCK1836 - SS WALL SHELFJOHN BOOS EWS8-1836-X- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCK1848 - SS WALL SHELFJOHN BOOS EWS8-1848-X- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCK1734- DELIVERY COUNTERCUSTOM - X X PROVIDED BY MILLWORK VENDORK1768 X DELIVERY COUNTERCUSTOM 1 X X PROVIDED BY MILLWORK VENDORK1824WX SS WALL SHELF (WIRE)AURORA UD WS1824C1 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCK1836W X SS WALL SHELF (WIRE)AURORA UD WS1836C7 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCK1848W- SS WALL SHELF (WIRE)AURORA UD WS1848C- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCK1860W- SS WALL SHELF (WIRE)AURORA UD WS1860C- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW1272- SS WORK TABLEAURORA MKW-1272- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW2424- SS WORK TABLEAURORA MKW-2424- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW2430- SS WORK TABLE - X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW2436- SS WORK TABLEAURORA MKW-2436-N- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW2448- SS WORK TABLEAURORA MKW-2448-N- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3024- SS WORK TABLEJOHN BOOS ST6-3024 SSK-X- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3030- SS WORK TABLEJOHN BOOS ST6-3030 SSK-X- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3036 - SS WORK TABLEJOHN BOOS ST6-3036 SSK-X- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3036CX SS WORK TABLE WITH 5" HEAVY DUTY CASTERS JOHN BOOS ST6-3036 SSK-X2 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3042- SS WORK TABLEJOHN BOOS ST6-3042 SSK-X- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3048 - SS WORK TABLEJOHN BOOS ST6-3048 SSK-X- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3048C - SS WORK TABLE WITH 5" HEAVY DUTY CASTERS JOHN BOOS ST6-3048 SSK-X- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3048.1- SS WORK TABLE WITH HOLES FOR SOUP CUPS JOHN BOOS ST6-3048 SSK-X- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW1860S- SS WORK TABLE WITH HOLES FOR SOUP CUPS JOHN BOOS -- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3060 SS WORK TABLEJOHN BOOS ST6-3060 SSK-X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3036CS X SS WORK TABLE WITH 5" HEAVY DUTY CASTERS, TOP AT 24" AFF JOHN BOOS ST6-3036 SSK-X1 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3060CS - SS WORK TABLE WITH 5" HEAVY DUTY CASTERS, TOP AT 24" AFF JOHN BOOS ST6-3060 SSK-X- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3060S- SS WORK TABLE WITH HOLES FOR SOUP CUPS JOHN BOOS ST6-3060 SSK-X- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3096 - SS WORK TABLE - X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3624- SS WORK TABLEAURORA MKW-3642- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3636- SS WORK TABLEJOHN BOOS ST6-3636 SSK- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3636H- SS WORK TABLE WITH 3630 BASE & 6" OVERHANG JOHN BOOS ST6-3636 SSK-X1 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3630HX SS WORK TABLE WITH 3030 BASE & 6" OVERHANG JOHN BOOS -2 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3642- SS WORK TABLEJOHN BOOS ST6-3642 SSK- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3648- SS WORK TABLE - X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3054- SS WORK TABLE - X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3660- SS WORK TABLEAURORA MKW-3660- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW3672- SS WORK TABLEAURORA MKW-3672- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW4236- SS WORK TABLEAURORA ST6-4236 SSK-X- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW6636- SS WORK TABLEAURORA MKW-6636- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKW7224- SS WORK TABLEAURORA MKW-7224- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS1424- STORAGE SHELVING (WIRE)AURORA WS-1424- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS1430R X STORAGE SHELVING (WIRE)AURORA WS-1430E8 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS1430 - STORAGE SHELVING (WIRE)AURORA WS-1430- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS1430C - STORAGE SHELVING (WIRE), 5" HEAVY DUTY CASTERS AURORA WS-1430- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS1436X STORAGE SHELVING (WIRE)AURORA WS-1436E3 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS1442- STORAGE SHELVING (WIRE)AURORA WS-1442E- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS1448- STORAGE SHELVING (WIRE)AURORA WS-1448- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS1454 - STORAGE SHELVING (WIRE)AURORA WS-1454- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS1824X STORAGE SHELVING (WIRE)AURORA WS-1824E1 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS1830- STORAGE SHELVING (WIRE)AURORA WS-1830- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS1836- STORAGE SHELVING (WIRE)AURORA WS-1836C- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS1836C- STORAGE SHELVING (WIRE), 5" HEAVY DUTY CASTERS AURORA WS-1836C- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS1842- STORAGE SHELVING (WIRE) - X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS1848X STORAGE SHELVING (WIRE)AURORA WS-1848C1 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS1854- STORAGE SHELVING (WIRE)AURORA WS-1854C- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS1860- STORAGE SHELVING (WIRE)AURORA WS-1860C- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS1872- STORAGE SHELVING (WIRE)AURORA WS-1872C- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS2430- STORAGE SHELVING (WIRE)AURORA WS-2430- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS2436- STORAGE SHELVING (WIRE)AURORA WS-2436- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS2442C- STORAGE SHELVING (WIRE), 5" HEAVY DUTY CASTERS AURORA WS-2442- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS2442- STORAGE SHELVING (WIRE)AURORA WS-2442- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS2448- STORAGE SHELVING (WIRE)AURORA WS-2448- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKS2454X STORAGE SHELVING (WIRE)AURORA WS-24541 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCKD2024X DUNNAGE RACKUPDATE INT'L DNRK-20242 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCNOTE: ALL EQUIPMENT IS TO BE NSF CERTIFIED. VERIFY ALL EQUIPMENT PRIOR TO INSTALLATIONAR11600168PRELIMINARY CONCEPT 1 03.08.2017ERBERT& GERBERT'SSANDWICH SHOPPRINT HISTORY DATEPROJECT:DRAWN:CHECKED:SIGNATURE:REGISTRATION:I hereby certify the this plan was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of INDIANARYAN SCHROEDER17020CBRS102 E. CARMEL DRCARMEL, INDIANAERBERT& GERBERT'SSANDWICH SHOPFINAL CONCEPT 03.16.2017CORPORATE REVIEW 03.31.2017BUILDING / HEALTH REVIEW 04.06.2017HUNTERS QUEST102 E. CARMEL DRIVECARMEL, IN 46033EXPLORATORY EXHIBIT 02.21.2017LANDLORD PRELIM REVIEW 03.28.2017CDR REVISION / REVISION #1 04.26.201711 FS-3EQUIPMENT SCHEDULEEQUIPMENT SCHEDULE: Carmel, IndianaDATE 04.20.2017 ITEM #EQUIPMENT TO BE USED AT THIS LOCATION IS MARKED WITH AN (X) ITEM DESCRIPTIONMANUFACTURER MODELQTYPLUMBINGELECTGASSUPPLIED BY OWNERSUPPLIED BY GCSUPPLIED BY VENDORINSTALLED BY OWNERINSTALLED BY GCINSTALLED BY VENDOREXISTING EQUIPMENT TO REMAINEXISTING EQUIPMENT TO RELOCATEDEQUIPMENT COMMENTSO: OFFICE O100 X OFFICE SAFE- BY OWNER1 X X BY OWNERO101 X OFFICE CHAIR- BY OWNER1 X X BY OWNERO102 X OFFICE DESKCUSTOM -1 X X PROVIDED BY MILLWORK VENDORO103 X ORDER MONITORING EQUIPMENT- -1 X X BY POS SUPPLIERO104 X LOCKERSWIN-HOLT EQUIP WL-661 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCO105 X PHONE- -1 X X BY POS SUPPLIERO106 X WALL MOUNTED SECURITY CABINETCUSTOM BY OWNER1 X X POS STORAGEP: PLUMBING P100X MOP SINK WITH SERVICE FAUCET BY PLUMBER1X X X INSTALLED BY GC.P101X 3 COMPARTMENT SINKAURORA MKS3-1620-2D-181X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCP102X 3 COMPARTMENT SINK PRE RINSE WITH ADD A FAUCET KROWNE METAL 17-108W1X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GC P103X 3 COMPARTMENT SINK LEVER TWIST DRAINST AND S BRASS WORKS B-39523X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GC P104X PREP SINK (LEFT HAND DRAIN BOARD)AURORA MKS1-1D-L1X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCP105 - PREP SINK (RIGHT HAND RIGHT DRAIN BOARD) AURORAMKS1-1D-R-X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCP106X PREP SINK FAUCETKROWNE METAL 14-8121X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GC P107X PREP SINK LEVER TWIST DRAINST AND S BRASS WORKS B-39521X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCP108 X HAND WASH SINKJOHN BOOS PBHS-W-1410-P-SSLR-X2X X X INSTALLED BY GC.P109 X WATER FILTERMANITOWOC AR-PRE2X X X VERIFYP110- STAINLESS STEEL SPLASH GUARD (IF REQ'D)CULINEX -- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCR: REFRIGERATION EQUIPMENT ] R100- 3 DOOR REACH IN FREEZERTRUE T-72F- X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCR101- 3 DOOR REACH IN COOLERNORLAKE NLF49-S- X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCR102- WALK IN COOLER/FREEZER. 6' X 12'NORLAKE KOLD LOCKER- X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GC. NO COOLER FLOOR. NO RAMP.R103X WALK IN COOLER. 6' X 6'NORLAKE KOLD LOCKER1 X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GC. NO COOLER FLOOR.R104X WALK IN FREEZER. 6' X 6'NORLAKE KOLD LOCKER1 X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GC. NO RAMP.R105- 2 DOOR REACH IN COOLERTRUE T-49- X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCR106- 2 DOOR REACH IN FREEZERNORLAKE NLR72-S- X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCR107- 1 DOOR REACH IN COOLER- -- X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCR108- 1 DOOR REACH IN FREEZER- -- X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCR109- ICE CUBER AND STORAGE BINMANITOWOC RN-1008A ON B570 BIN-XX X X SUPPLIED BY EQUIP SUPPLIER. INSTALLED BY GC. S: SERVING S100 X CO2 TANK/S- BY OTHERS2 BY OTHERSS101 X BAG IN THE BOX SODA SYSTEM- BY SODA PROVIDER1 X SUPPLIED AND INSTALLED BY SODA VENDORS102 X SODA DISPENSER- BY SODA PROVIDER2 X X SUPPLIED AND INSTALLED BY SODA VENDORS102.1 X LID DISPENSER HANGINGSAN JAMAR CHEF REVIVAL L34021 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCS102.2- SODA GRATE DRAIN- -- X X PROVIDED BY EQUIPMENT SUPPLIER. 48" LONG. VEIRFY SIZE. INSTALLED BY GCS102.3XTRASH CAN RINGCUSTOM 1 X XX 6" RING PROVIDED BY MILLWORK VENDOR.S103- GLASS DOOR MERCHANDISERTRUE GDM-12- X X X SUPPLIED AND INSTALLED BY SODA VENDORS104 X ICE CUBERMANITOWOC IY-0454A2XX X X SUPPLIED BY EQUIP SUPPLIER. INSTALLED BY GC. S105A - SODA CABINET AT DININGCUSTOM - X X PROVIDED BY MILLWORK VENDORS105B X SODA CABINET W/ TRASH AT DININGCUSTOM 1 X X PROVIDED BY MILLWORK VENDORS105.1 -TRASH CAN- - X XX PROVIDED BY OWNER INSTALLE BY GCS106X REFRIGERATED SANDWICH TABLENORLAKE NLSMP72-301 X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCS107X REFRIGERATED SANDWICH TABLE WITH OVERSHELF TRUE NLSMP72-30 W/ OS1 X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCS108- UNDERCOUNTER REFRIGERATOR- -- X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCS109- SOUP WARMER STAND ALONE - X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCS109AX SOUP WARMERHATCO CHW-32 X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCS110- CASHIER COUNTERCUSTOM - X X X PROVIDED BY MILLWORK VENDORS111- CUP DISPENSERS AT SODA MACHINE- -- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCS112X CUP DISPENSERS AT POSDISPENSE-RITE ADJ-26 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCS113- WASTE RECEPTACLESCUSTOM -- X X PROVIDED BY MILLWORK VENDORS114 X OVEN PROOFERPIPER PRODUCTS OP-31 X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCS115 X SLICERHOBART HS6N-12 X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCS116 X SCALERUBBERMAID 18125912 X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCS117- CHIP RACK- -- X X PROVIDED BY CHIP VENDORS118X SOUP CUP & LID WALL UNITCUSTOM -1 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCS119X STAINLESS STEEL SYRUP CHASECUSTOM -2 X X SUPPLIED AND INSTALLED BY GCS120- TURBO CHEFTORNADO 2 -- X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCS120.1- TURBO CHEF OVEN CART 24"TORNADO 2 NGC-1217-1- X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCS121- DBL SIDED REF SANDWICH TABLE WITH OVERSHELF TRUE TSSU-72-30M-DS-ST- X X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCS122- COFFEE/TEA BREWERBUNN ITCB-XX X X SUPPLIED AND INSTALLED BY SODA VENDORS122.1- TEA DISPENSERBUNN TDO-N-3.5- X X SUPPLIED AND INSTALLED BY SODA VENDORS122.2- COFFEE DISPENSERBUNN TDO-N-3.5- SUPPLIED AND INSTALLED BY SODA VENDORS123 X DROP IN COLD FOOD PAN W/ BOTTOM PLATEWELLS ICP-1001 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCS124 X SS STRAW HOLDER- -1 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCS125 X COOKIE/BREAD DISPLAYCUSTOM -1 X X PROVIDED BY EQUIPMENT SUPPLIER. INSTALLED BY GCU: SECURITY/COMMUNICATION/POS U100 X PRINTER- BY POS SUPPLIER7 X X U101 X FRONT COUNTER POS- BY POS SUPPLIER2 X X U102 X CARD SWIPE- BY POS SUPPLIER3 X X U103 X CASH DRAWER- BY POS SUPPLIER3 X X U104 X DRIVE THRU POS WALL MOUNTED- BY POS SUPPLIER1 X X U105 X WALL MOUNTED PHONE- BY DATA3 X X U106 X WALL MOUNTED POS- BY POS SUPPLIER3 X X U107 X DRIVE THRU MENU BOARD- DTX 354 3 PANEL. VERIFY.1 X X U108 X DRIVE THRU SPEAKER POST- -1 X X U109 X DRIVE THRU CLEARANCE BAR- -1 X X U110 X DRIVE THRU COMMUNICATIONS PANEL- -1 X X V: SERVING AREA V99X GALVANIZED PANELSCUSTOM -8 X X FOR E/G SUPPLIED SIGNAGENOTE: ALL EQUIPMENT IS TO BE NSF CERTIFIED. VERIFY ALL EQUIPMENT PRIOR TO INSTALLATIONAR11600168PRELIMINARY CONCEPT 1 03.08.2017ERBERT& GERBERT'SSANDWICH SHOPPRINT HISTORY DATEPROJECT:DRAWN:CHECKED:SIGNATURE:REGISTRATION:I hereby certify the this plan was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of INDIANARYAN SCHROEDER17020CBRS102 E. CARMEL DRCARMEL, INDIANAERBERT& GERBERT'SSANDWICH SHOPFINAL CONCEPT 03.16.2017CORPORATE REVIEW 03.31.2017BUILDING / HEALTH REVIEW 04.06.2017HUNTERS QUEST102 E. CARMEL DRIVECARMEL, IN 46033EXPLORATORY EXHIBIT 02.21.2017LANDLORD PRELIM REVIEW 03.28.2017CDR REVISION / REVISION #1 04.26.2017