HomeMy WebLinkAbout170424_Midtown Carmel Office Bld_Structural DrawingsUP UP DN A B C D 1 2 3 4 5 6 7 8 105' - 6" 39' - 0"25' - 0"39' - 0"190' - 0"10' - 0"30' - 0"30' - 0"30' - 0"30' - 0"30' - 0"30' - 0"F5 F7 F3812 F6 F8 F8 F8 F8 F8 F7 F8F8 F7 F8 F8 F8 F8 F8 F7 F5 F9 F9 F9 F9 F9 F9 F4516 MAT01 SOG04P T/SLAB +100' - 0" 1 S407TYP2 S407 3 S407 4 S407 S403 9 S403 8 S403 7 5 S407TYP6 S407 9 S405 11 S405 12 S405 S403 5 D.1 2/ S501 1/ S5013/ S501 2' - 6"1' - 10"CW14WF48R6' - 0"8' - 0"11' - 0" 13 S405 W12X22 +96' - 2" CW24 CW24T/F +92' - 0" T/F +92' - 0" WF48R WF48R T/F +95' - 0"CW14WF48RT/F +92' - 0" T/F +92' - 0" WF24 WF24 CW10 CW14WF30HSS12X4X5/16 HSS12X4X3/8 HSS12X4X5/16 (VERIFY) 5' - 8" WF24 CW14 WF30 WF48R CW14 T/F +94' - 0" P28 T/P +99' - 4" P28 T/F +94' - 0" T/P +99' - 4" T/P +99' - 4" T/F +94' - 0" P28 P28 T/P +99' - 4" T/F +94' - 0" P28 T/P +99' - 4" T/F +94' - 0" P28 T/P +96' - 4" T/F +95' - 0" P28 T/P +96' - 4" T/F +95' - 0" P28 T/P +96' - 4" T/F +95' - 0" WF48R T/F +95' - 0" T/F +94' - 0" T/F +94' - 0" CW14 T/F +94' - 0"P28 F6 T/P +99' - 4" T/F +94' - 0" CW14 T/F +94' - 0"T/F +94' - 0"T/F +94' - 0"WF30 CW14CW14 WF30WF30 P28 T/P +99' - 4" T/F +94' - 0" P28 T/F +94' - 0" T/P +99' - 4" T/F +94' - 0" P5252P40 T/P +99' - 0"T/P +99' - 0" SEE CIVIL DRAWINGS FOR RETAINING WALL FOUNDATION THIS AREA P28 T/P +99' - 4" T/F +98' - 0" P28 T/P +99' - 4" T/F +98' - 0"T/F +98' - 0"P28 T/P +99' - 4" T/F +98' - 0" P28 T/P +99' - 4" T/F +98' - 0" P28 T/P +99' - 4" T/F +98' - 0" P28 T/P +99' - 4" T/F +98' - 0" P28 T/P +99' - 4" T/F +98' - 0" P5252 T/P +99' - 0" P5252 T/P +99' - 0" P28 P28 T/P +99' - 4" T/F +94' - 0" T/P +99' - 4" T/F +94' - 0"T/F +95' - 0"T/F +95' - 0" T/F +95' - 0"CW8T/F +95' - 0"T/F +95' - 0"WF48R CW14 SOG4P (FUTURE) SOG4P (FUTURE) SOG4P (FUTURE) T/F +98' - 0"T/F +98' - 0" T/F +99' - 4"T/F +99' - 4" T/F +98' - 0" T/F +98' - 0" SOG04P T/SLAB +97' - 0" F9 P28 T/F +99' - 4" T/F +95' - 0" CW10 T/SLAB +92' - 0" CW8 CW8CW8 CW8CW8 CW8F4516 CW8CW8 CW8WF24 WF24T/F +94' - 0" SOG04P T/SLAB +98' - 6" 9 S405 9 S405 1' - 10"1' - 10"1' - 10"1' - 10"1' - 10" 1' - 0 1/8"16' - 5 1/8"7' - 6 3/4" HSS12X4X3/8 T/LDG +95' - 4"T/LDG +96' - 8"T/LDG +98' - 8" T/LDG +98' - 8" T/LDG +95' - 4" T/LDG +95' - 4" T/LDG +95' - 4" T/LDG +95' - 4" T/LDG +95' - 4" T/LDG +96' - 8" T/LDG +95' - 2" T/LDG +96' - 8" T/LDG +98' - 8" T/LDG +98' - 8" T/LDG +98' - 8" CW24S403 6 NOTE: COORDINATE LEDGE STEPS WITH FINAL SITE AND ARCHITECTURAL PLANS. F4 P20 T/P +96' - 4" T/F +94' - 0" F4 P20 T/P +96' - 4" T/F +94' - 0" F4 P20 T/P +96' - 4" T/F +94' - 0"12' - 5"9' - 3"8' - 4"33' - 10"8' - 4"3.4 3.6 E 4' - 3" 1' - 9" F7 S412 SEE ARCH FOR EXTENTS OF RECESSED SLAB THIS AREA SEE ARCH FOR EXTENTS OF RECESSED SLAB THIS AREA 5' - 9"13' - 6"8' - 7 1/8" 8' - 7 1/8" B/WALL 7 S407 PROVIDE 3/8x4"x8" EMBEDS w/(2) 1/2"x4" HS AT EA STAIR STRINGER ATTACHMNET POINT IN WALL AND SLAB. COORDINATE LOCATIONS AND ELEVATIONS w/ STAIR SHOP DRAWINGS. COORDINATE OFFSETS WITH FINAL GEOMETRY ON ARCHITECTURAL F/WALL10' - 0"4 4 4 CW10CW10 WF30 WF30SS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m Construction Manager: Civil Engineer: Owner: MIDTOWN EAST BLOCK 3 OFFICE 55 Monument Circle, Suite 450 Indianapolis, IN 46204 317-507-6067 F.A. WILHELM CONSTRUCTION COMPANY 3914 Prospect St. Indianapolis, IN 46203 317-359-5411 Civil & Environment Consultants, Inc. 560 E. Ohio Street Suite G Indianapolis, IN 46204 Structural Engineer: McComas Engineering 1717 East 116th Street Suite 200 Carmel, IN 46032 MEP Engineer: Freije 11800 Exit 5 Pkwy Suite 106 Fishers, IN 46037 PERMIT ISSUE 2017-04-24 571 Monon Blvd. Carmel, INKLS CRM 2017-02-27 S101 FOUNDATION PLAN MEI 17017MIDTOWN EAST BLOCK 3 OFFICESCALE: 1/8" = 1'-0" FOUNDATION PLAN FOUNDATION PLAN NOTES: 1. ELEVATIONS ±, ARE FROM NOMINAL FIRST FLOOR ELEV +100'-0", SEE CIVIL DRAWINGS. 2. SEE S401 FOR GENERAL NOTES AND SCHEDULES. 3. SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS NOT SHOWN. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION AND NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES IMMEDIATELY. 4. TOP OF FOOTING (T/F) -2'-0", UNO. 5. TOP OF PIERS (T/P) -0'-8", UNO. PLAN NORTH 0 1'4'8'16'2' 1 1 1 2 2 2 3 4 # DESCRIPTION DATE 1 Addendum 01 2017-03-13 2 Addendum 02 2017-04-03 3 Addendum 03 2017-04-12 4 Addendum 04 2017-04-17 UP DN UP UP DN UP A B C D 1 2 3 4 5 6 7 8W21X44W12X16+114' - 10"W12X16 +114' - 10" W12X16 W12X16 W12X16 W12X16 +114' - 10" W12X16 +114' - 10"W21X68+114' - 10"105' - 6" 39' - 0"25' - 0"39' - 0"190' - 0"10' - 0"30' - 0"30' - 0"30' - 0"30' - 0"6 EQ SPA = 30' - 0"30' - 0"+114' - 10" +114' - 10" +114' - 10"S02T/SLAB +115' - 4"9 S408 1 S408 5 S408 3 S409 1 S409 2 S409 TYPPIER &CANOPY12 S408 10 S408 4 S409 12 S405 11 S405 8 S408 2 S408 3 S408 4 S408 PIERWALLWINDOWWALLWINDOW6 S408 PIER7 S408TYP WINDOW11 S408 D.1 W18X35W18X35W24X55W24X68W24X62W14X22W24X55W12X22 W12X22 W24X68+115' - 6"W24X55W24X55W27X94W21X48W27X94W24X68+115' - 6"W24X55W24X55W10X12W12X16W10X12W14X22W24X6818LH0618LH0624LH0824LH0824LH0824LH0824LH0824LH0824LH08S02 2/ S501 1/ S5013/ S501W10X12 W10X12W10X12W10X12W10X12W10X12W10X12W10X12W10X12W14X22W10X12W10X12W10X12W10X12W10X12W18X3510' - 6 1/2"9' - 2 1/2"8' - 5 1/2"24LH07 24LH07 24LH07 24LH07 24LH07 24LH0724LH07 24LH0724LH07 24LH0724LH0724LHSP11' - 9 1/2"(FRAME) (FRAME)(FRAME)W24X682' - 6" W24X131 +115' - 1" W21X57 +115' - 1" W24X131 +115' - 1" W24X94 +115' - 1" W21X62 +115' - 1" W24X94 +115' - 1" W10X12 W18X35 W24X131 +115' - 1" W21X57 +115' - 1" W24X131 +115' - 1" W24X131 +115' - 1" W21X57 +115' - 1" W24X131 +115' - 1" W24X146 +115' - 1" W24X131 +115' - 1" W24X146 +115' - 1" W21X55 +115' - 1" W24X131 +115' - 1" W21X44 +115' - 1" W21X55 +115' - 1" W30X148 +115' - 1" W24X62 +115' - 1" W30X132 +115' - 1" 13 S408 W10X12W18X35WT8X25 WT8X25 WT8X25 WT8X25 WT8X25 WT8X25 WT8X25 WT8X25 WT8X25 WT8X25 WT8X25 WT8X25 WT8X25 WT8X25 WT8X25 WT8X25 WT8X25 WT8X25 W18X35W18X35W18X35W18X353 EQ SPA = 30' - 0"3 EQ SPA = 30' - 0"3 EQ SPA = 30' - 0"3 EQ SPA = 30' - 0"3 EQ SPA = 30' - 0"2' - 0"26' - 0"2' - 0"6' - 3"4' - 0"7 EQ SPA = 35' - 0"5 EQ SPA = 25' - 0"4' - 0"7 EQ SPA = 35' - 0"W12X16W ALL12k12k67k 40k 40k 73k 31k28k33k23k30k 30k 69k 36k 32k 73k 19k12k54k 54k 32k 32k 56k 54k 12k10k10k12k28k28k69k 63k 10k10k28k28k69k 85k 53k53k69k 69k 28k12k13k41k 41k 12k16k69k67k 16k18k18k10k10k4' - 1"EOS7 1/2"EOS1' - 2"EOS 1' - 2"EOS1' - 2"EOS 1' - 2"28k69k 67k 28k28k69k 67k 28k28k48k 47k 32k 31k 12k21k41k 41k 12k12k69k67k 18k18k12k12k42k 42k 12k12k69k67k 18k18k12k12k43k 48k 48k47k 18k23k 26k 32k31k21k21kEOS 3 3/4" 4' - 10" EOS 4" 0" EOS EOS1' - 1"EOS3"EOS3"12' - 5 3/4" EOS 1' - 4 1/4" 1' - 2 1/4" EOS W10X12EOS2 1/2"HSS12x4x5/16 ELEVATOR RAIL COLUMN (4 PER FLOOR TYP) COORDINATE LOCATIONS WITH ELEVATOR SUPPLIER EOS4"EOS 1' - 1"EOS4"5 S409 6 S409 7 S409 6 S409 8 S409 HSS5X5X3/8 DECK SUPPORT 7' - 1" 4 S409 5 S409 6 S409 EOS 1' - 2"EOS1' - 2"0" EOS 2 S409 3 S409PIER &CANOPYTYPRD02RD02RD02RD02RD02W12X30+109' - 1"W12X30+109' - 1"WT6X25 WT6X25 WT6X25 WT6X25 WT6X25 W12X30 +108' - 0 11/16" 1' - 9" 5' - 7"6"2' - 6 3/8"RD0229' - 7"9' - 3"1' - 11"W12X30+109' - 1"W12X30+109' - 1"W12X30 +109' - 1" W12X30 +109' - 1" WT6X25 WT6X25 WT6X25 WT6X25WT6X25WT6X25WT6X25WT6X25WT6X25WT6X25 WT6X25 W12X30 +108' - 0 11/16" 5' - 0" TYP W12X30+109' - 1"W10X12 +109' - 1"WT6X25 9' - 6"11' - 7 1/4"3.4 3.6 E F 1' - 9" 4' - 3"12' - 4 3/4"8' - 4"7 S412EOS3 1/4"EOS 9" 4' - 9"4' - 1"L6X6X5/16BELOWL6X6X5/16 BELOW EOS 1' - 2"EOS1' - 2"W18X35W12X22 W18X3518LH0618LH06SEE S201 FOR SHAFT 11k11k20k 13k12' - 7 3/4"W10X124" EOS4" EOS 4" EOS EOS1' - 11 1/2"EOS8"W18X40W12X22 W12X22 W10X12W10X12W10X12W10X12SEE S201 FOR SHAFT L5x4x1/4 FRAME BELOW DECK FOR FUTURE OPENINGS 17k11kW18X40TYP 4" EOS 6' - 5 1/2"17' - 10 1/2"8"2' - 0"6' - 5 1/2"4' - 3"18LH0518LH0518LH05FUTURE CHASEBELOWL6X6X5/1630'-0". LOAD DL Max Total k/ft W1 0.410 0.750 1.160 W2 0.410 0.250 24LHSP1 10'-0".20'-0". W1 W2 k/ft LL k/ft 0.735 PL k/ft 0.075 DL = Dead Load LL = Live Load PL = Partition Load SS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m Construction Manager: Civil Engineer: Owner: MIDTOWN EAST BLOCK 3 OFFICE 55 Monument Circle, Suite 450 Indianapolis, IN 46204 317-507-6067 F.A. WILHELM CONSTRUCTION COMPANY 3914 Prospect St. Indianapolis, IN 46203 317-359-5411 Civil & Environment Consultants, Inc. 560 E. Ohio Street Suite G Indianapolis, IN 46204 Structural Engineer: McComas Engineering 1717 East 116th Street Suite 200 Carmel, IN 46032 MEP Engineer: Freije 11800 Exit 5 Pkwy Suite 106 Fishers, IN 46037 PERMIT ISSUE 2017-04-24 571 Monon Blvd. Carmel, INKLS JRH & CRR 2017-02-28 S201 SECOND FLOOR FRAMING PLAN MEI 17017MIDTOWN EAST BLOCK 3 OFFICESCALE: 1/8" = 1'-0" SECOND FLOOR FRAMING PLAN FRAMING PLAN NOTES: 1. ELEVATIONS ±, ARE FROM NOMINAL FIRST FLOOR ELEV +100'-0", SEE CIVIL DRAWINGS. 2. SEE S401 FOR GENERAL NOTES AND SCHEDULES. 3. SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS NOT SHOWN. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION AND NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES IMMEDIATELY. 4. COORDINATE DECK OPENINGS - EXACT SIZE AND LOCATION, WITH MECHANICAL CONTRACTOR DRAWINGS AND EQUIPMENT SUPPLIER. 5. T/STL ELEV +115'-6" (UNO). 6. JOIST BRG ELEV +115'-1" (UNO). PLAN NORTH 0 1'4'8'16'2' SCALE:S201 3/4" = 1'-0" 2JOIST LOAD DIAGRAM - 24LHSP1 1 2 2 2 2 2 2 2 2 2 2 # DESCRIPTION DATE 1 Addendum 01 2017-03-13 2 Addendum 02 2017-04-03 UPUP DN UP DN UP A B C D 1 2 3 4 5 6 7 8 105' - 6" 39' - 0"25' - 0"39' - 0"190' - 0"10' - 0"30' - 0"30' - 0"30' - 0"30' - 0"30' - 0"30' - 0"D.1 W24X146 +129' - 1"W18X35W18X35W24X55W10X12 W21X55 +129' - 1" W24X131 +129' - 1"W24X55W24X55W21X44 +129' - 1"W12X16W14X22W12X22 W12X22 W24X55W24X55W24X55W27X94W21X48W27X94W24X55W14X22 W24X55W10X12W12X16W10X12W14X22W24X5518LH0618LH0624LH0824LH0824LH0824LH0824LH0824LH0824LH08S02W10X12 W10X12W10X12W10X12W10X12W10X12W10X12W10X12W10X12W14X22W10X12W10X12W10X12W10X12W10X12W10X12W10X1210' - 6 1/2"9' - 2 1/2"8' - 5 1/2"24LH07 24LH0724LH07 24LH0724LH07 24LH0724LH07 24LH0724LH07 24LH0724LH0724LHSP11' - 9 1/2"(FRAME) (FRAME)(FRAME)W24X552/ S501 1/ S5013/ S501 2' - 6"W24X55W30X148 +129' - 1" W24X62 +129' - 1" W30X132 +129' - 1" W24X146 +129' - 1" W21X55 +129' - 1" W24X131 +129' - 1" W24X131 +129' - 1" W21X62 +129' - 1" W24X131 +129' - 1" W24X131 +129' - 1" W21X62 +129' - 1" W24X131 +129' - 1" W24X131 +129' - 1" W21X62 +129' - 1" W24X131 +129' - 1" W24X94 +129' - 1" W21X62 +129' - 1" W24X94 +129' - 1"W18X35EOS1' - 1"W24X55EOS 3 3/4"12k12k67k 40k 40k 73k 31k28k33k23k30k30k 67k 36k 32k 73k 19k12k54k 54k 32k 32k 56k 54k 12k10k10k12k18k18k69k 63k 10k10k18k18k69k 85k 18k18k69k 67k 18k12k13k41k 41k 12k16k69k67k 16k18k18k18k69k 67k 18k18k69k 67k 18k18k48k 47k 32k 31k 12k21k41k 41k 12k12k69k67k 18k18k12k12k42k 42k 12k12k69k67k 18k18k12k12k43k 48k 48k47k 18k23k 26k 32k31kEOS4"EOS 1' - 1" 0" EOS EOS2"EOS1' - 8"EOS 1' - 2" EOS 1' - 2"EOS8"EOS 1' - 2"4' - 1"EOS1' - 1 1/2"0" EOS 10k10k4' - 0"7 EQ SPA = 35' - 0"5 EQ SPA = 25' - 0"4' - 0"7 EQ SPA = 35' - 0" 12' - 5 3/4"W10X1212 S405 11 S405 4' - 10" EOS 1' - 4 1/4" 1' - 3" EOS EOS2 1/2"EOS 4" HSS12x4x5/16 ELEVATOR RAIL COLUMN (4 PER FLOOR TYP) COORDINATE LOCATIONS WITH ELEVATOR SUPPLIER L6x4x3/8 LLV COPED OVER JOISTS WHERE STAIR STINGERS BEAR ON SLAB 8' - 11"EOS8"8 S409 6 S409 6 S409 5 S409 4 S409 7 S409 EOS3"4 S409 5 S409 6 S409 4' - 9"4' - 1" SEE S201 FOR SHAFT SEE S201 FOR SHAFT SEE S201 FOR SHAFT 14 S408 W18X4018LH0518LH0518LH05W18X40W12X22 W12X22 W10X12W10X12W10X126' - 5 1/2"4' - 3"6' - 5 1/2"17' - 10 1/2"8"2' - 0" L5x4x1/4 FRAME BELOW DECK FOR FUTURE OPENINGS TYP 4" EOS11k 11k12k 17kW18X3518LH0618LH06W18X3513k20kW12X22 W10X1211k11k 4' - 8"8" EOSEOS1' - 11 1/2"4" EOS4" EOS 4" EOS 12' - 7 3/4" EOS 1' - 2" EOS 9"EOS1' - 2"3 1/4" EOSHSS5x5x3/8 DECK SUPPORTFUTURE CHASESS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m Construction Manager: Civil Engineer: Owner: MIDTOWN EAST BLOCK 3 OFFICE 55 Monument Circle, Suite 450 Indianapolis, IN 46204 317-507-6067 F.A. WILHELM CONSTRUCTION COMPANY 3914 Prospect St. Indianapolis, IN 46203 317-359-5411 Civil & Environment Consultants, Inc. 560 E. Ohio Street Suite G Indianapolis, IN 46204 Structural Engineer: McComas Engineering 1717 East 116th Street Suite 200 Carmel, IN 46032 MEP Engineer: Freije 11800 Exit 5 Pkwy Suite 106 Fishers, IN 46037 PERMIT ISSUE 2017-04-24 571 Monon Blvd. Carmel, INKLS CRM 2017-02-27 S202 THIRD FLOOR FRAMING PLAN MEI 17017MIDTOWN EAST BLOCK 3 OFFICESCALE: 1/8" = 1'-0" THIRD FLOOR FRAMING PLAN FRAMING PLAN NOTES: 1. ELEVATIONS ±, ARE FROM NOMINAL FIRST FLOOR ELEV +100'-0", SEE CIVIL DRAWINGS. 2. SEE S401 FOR GENERAL NOTES AND SCHEDULES. 3. SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS NOT SHOWN. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION AND NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES IMMEDIATELY. 4. COORDINATE DECK OPENINGS - EXACT SIZE AND LOCATION, WITH MECHANICAL CONTRACTOR DRAWINGS AND EQUIPMENT SUPPLIER. 5. T/STL ELEV +129'-6" (UNO). 6. JOIST BRG ELEV +129'-1" (UNO). 7. SEE S201 FOR SECTION CUTS. PLAN NORTH 0 1'4'8'16'2' 2 2 2 2 2 # DESCRIPTION DATE 2 Addendum 02 2017-04-03 UP DN UP DN A B C D 1 2 3 4 5 6 7 8 105' - 6" 39' - 0"25' - 0"39' - 0"190' - 0"10' - 0"30' - 0"30' - 0"30' - 0"30' - 0"30' - 0"30' - 0"W18X40W18X40W24X55W24X55W24X55W21X44W12X16 W14X22W24X55W12X22 W12X22 W24X55W24X55W24X55W24X55W27X94W21X48W27X94W24X55W14X22 W24X55W10X12W12X16W10X12W14X22W24X10418LH0618LH0624LH0824LH0824LH0824LH0824LH0824LH0824LH08S02 D.1 W10X12W10X12W10X12W10X12W10X12W10X12W10X12W10X12W10X12W14X22W10X12W10X12W10X12W10X12W10X12W10X12W10X1210' - 6 1/2"9' - 2 1/2"8' - 5 1/2"24LH07 24LH0724LH07 24LH07 24LH0724LH07 24LH0724LH07 24LH0724LH0724LHSP11' - 9 1/2"(FRAME) (FRAME)(FRAME)2/ S501 1/ S5013/ S501 2' - 6" W30X173 +143' - 1" W24X146 +143' - 1" W21X55 +143' - 1" W24X131 +143' - 1" W24X68 +143' - 1" W27X146 +143' - 1" W24X146 +143' - 1" W21X55 +143' - 1" W24X131 +143' - 1" W24X131 +143' - 1" W21X62 +143' - 1" W24X146 +143' - 1" W24X131 +143' - 1" W21X62 +143' - 1" W24X131 +143' - 1" W24X131 +143' - 1" W21X62 +143' - 1" W24X131 +143' - 1" W24X94 +143' - 1" W21X62 +143' - 1" W24X94 +143' - 1"W24X55W10X12EOS1' - 1"EOS3"EOS 3 3/4" +143' - 1" 0" EOS EOS4"EOS 1' - 1" 0" EOS EOS4"EOS1' - 2"EOS 1' - 2" EOS 1' - 2"EOS1' - 2"EOS 1' - 2"4' - 1"EOS7 1/2"W18X4060k 60k 36k 36k 63k 63k 12k12k14k14k12k12k23k23k69k 67k 38k 38k 73k 63k 34k32k14k14k33k23k23k23k31k30k 59k 73k 37k 32k 73k 85k 19k12k44k39k76k 89k 23k23k69k 67k 23k23k69k 67k 23k23k48k 47k 32k 31k 12k13k41k 41k 12k16k69k67k 16k18k18k12k21k41k 41k 12k12k69k67k 18k18k12k12k42k 42k 12k12k69k67k 18k18k12k12k43k 48k 48k47k 18k23k 26k 32k31k10k10k4' - 0"7 EQ SPA = 35' - 0"5 EQ SPA = 25' - 0"4' - 0"7 EQ SPA = 35' - 0" 12' - 5 3/4"W10X1211 S405 4' - 10" 1' - 3" EOS EOS 1' - 4 1/4" 1' - 3" EOS EOS2 1/2"HSS12x4x5/16 ELEVATOR RAIL COLUMN (4 PER FLOOR TYP) COORDINATE LOCATIONS WITH ELEVATOR SUPPLIER EOS 4"16' - 5"3' - 4 1/8"5' - 3 1/4"1' - 5 1/4"15' - 4 1/4"1' - 0 3/4"9' - 8 5/8"W24X62W24X55W12X16 W12X16W12X16W12X16W12X16W12X16W10X12W16X269" EOS6" EOS 5 7/8" EOS6 " E O S 6 " E OS5 S408SIM EOS1' - 2"8 S409 6 S409 6 S409 4 S409 7 S409 5 S409 12 S405 6 S409 6 S409 4 S409 5 S409 6 S409 5 S409 SIM40k 40k 1 8 k 1 8 k 4' - 9"4' - 1" SEE S201 FOR SHAFT SEE S201 FOR SHAFT SEE S201 FOR SHAFT W18X40W10X12W10X12W10X12W10X12W12X22 W12X22 W18X35W18X4018LH0518LH0518LH0518LH0618LH0624LH07W12X22 W10X12W18X3513k20k11k11k EOS1' - 11 1/2"EOS8"EOS4"EOS 4" EOS 4" 6' - 5 1/2"17' - 10 1/2"8"2' - 0"6' - 5 1/2"4' - 3"L5x4x1/4 FRAME BELOW DECK FOR FUTURE OPENINGS EOS TYP 4"17k11k11k12k 9 S409 12' - 7 3/4" HSS5x5x3/8 DECK SUPPORTFUTURE CHASESS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m Construction Manager: Civil Engineer: Owner: MIDTOWN EAST BLOCK 3 OFFICE 55 Monument Circle, Suite 450 Indianapolis, IN 46204 317-507-6067 F.A. WILHELM CONSTRUCTION COMPANY 3914 Prospect St. Indianapolis, IN 46203 317-359-5411 Civil & Environment Consultants, Inc. 560 E. Ohio Street Suite G Indianapolis, IN 46204 Structural Engineer: McComas Engineering 1717 East 116th Street Suite 200 Carmel, IN 46032 MEP Engineer: Freije 11800 Exit 5 Pkwy Suite 106 Fishers, IN 46037 PERMIT ISSUE 2017-04-24 571 Monon Blvd. Carmel, INKLS CRM 2017-02-27 S203 FOURTH FLOOR FRAMING PLAN MEI 17017MIDTOWN EAST BLOCK 3 OFFICESCALE: 1/8" = 1'-0" FOURTH FLOOR FRAMING PLAN FRAMING PLAN NOTES: 1. ELEVATIONS ±, ARE FROM NOMINAL FIRST FLOOR ELEV +100'-0", SEE CIVIL DRAWINGS. 2. SEE S401 FOR GENERAL NOTES AND SCHEDULES. 3. SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS NOT SHOWN. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION AND NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES IMMEDIATELY. 4. COORDINATE DECK OPENINGS - EXACT SIZE AND LOCATION, WITH MECHANICAL CONTRACTOR DRAWINGS AND EQUIPMENT SUPPLIER. 5. T/STL ELEV +143'-6" (UNO). 6. JOIST BRG ELEV +143'-1" (UNO). 7. SEE S201 FOR SECTION CUTS. PLAN NORTH 0 1'4'8'16'2' 2 2 2 2 2 # DESCRIPTION DATE 2 Addendum 02 2017-04-03 A B C D 1 2 3 4 5 6 7 8 105' - 6" 39' - 0"25' - 0"39' - 0"190' - 0"10' - 0"30' - 0"30' - 0"30' - 0"30' - 0"30' - 0"30' - 0"S01 RD01RD01 1 S411 D.1 2' - 6" 1 S410 2 S410 3 S410 5 S410 6 S410 7 S410 8 S410 9 S410 2 S411 2/ S501 1/ S5013/ S501 20K3 20K320K3 20K320K3 20K320K3 20K320K3 20K3 10K1 W21X44 +158' - 9 1/2" W16X31 +158' - 9 1/2" W21X57 +158' - 9 1/2" W24X55 +159' - 4"W14X22+159' - 0"W14X22+159' - 0"W14X22W14X22+159' - 0"W21X62 +158' - 9 1/2" W21X55 +159' - 4"W24X62 +158' - 9 1/2"W21X44+159' - 4"W14X22W12X19+159' - 4"W12X19+159' - 4"W12X19+159' - 4"W12X19+159' - 4"W21X55+159' - 4"W14X22+159' - 0"W14X22+159' - 0"W21X44+159' - 4"W14X22W16X31+159' - 4"W16X40+159' - 4"W14X22+159' - 4"W14X22+159' - 4"W21X44+159' - 4"W14X22+159' - 0"W21X57 +159' - 4"W14X22+159' - 0"W14X22+159' - 0"W21X62 +158' - 9 1/2" W21X55 +159' - 4" W21X62 +158' - 9 1/2"W21X44+159' - 4"W14X22W16X31+159' - 4"W16X40+159' - 4"W10X12+159' - 4"W10X12+159' - 4"W21X44+159' - 4"W24X55 +159' - 4" W16X31 +158' - 7" W18X40 +158' - 9 1/2" W14X22 +158' - 9 1/2" W18X40 +158' - 9 1/2"W14X22+159' - 0"W14X22+159' - 0"W21X44+159' - 4"W14X22W16X31+159' - 4"W16X31+159' - 4"W16X31+159' - 4"W16X31+159' - 4"W21X44+159' - 4"W14X22+159' - 0"W14X22+159' - 0"W12X16+159' - 0"W12X16+159' - 0"W10X12W18X50 +159' - 4"W10X12W10X12W14X22+158' - 9 1/2" W21X44 +158' - 7"+158' - 7" W21X44 +158' - 9 1/2" +157' - 11 1/2" W21X62 +158' - 9 1/2" +158' - 9 1/2" W21X62 +157' - 11 1/2"+157' - 11 1/2" W21X62 +158' - 9 1/2" +158' - 9 1/2" W21X62 +157' - 11 1/8"+157' - 11 1/8" W24X62 +158' - 9 1/2" W10X12W14X22W14X22W10X12W10X12W10X1210' - 7 1/4"17k (SLOPED)10k17k 18k10k 18k 24k 16k24k 26k24k 26k 25k 34k 29k20k15k10k10k19k11k10k16k23k24k 35k24k 26k35k 29k +159' - 0"+159' - 0" ROOF DRAIN (RD) OVERFLOW DRAIN (OD) PROVIDE L3x3x1/4 ANGLE FRAME @ RD & OD (SEE 10/S406) (TYP) OD RD OD RD OD RD OD RD OD RD 8" EOD 8" EOD8" EOD 10" EOS10" EOS 1' - 0" EOS8" EOS8" EOD8" EOD 4' - 1"24k 24k 24k 24k 24k 24k 24k 24k 16k 16k 10k 10k 24k 24k 24k 24k 24k 24k 16k 16k 10k 10k 10k10k 28k28k 42k43k 42k43k 10k11k11k13k11k10k11k11k11k14k11k10k14k10k17k11k10k10k11k11k11k11k10k10k11k11k11k11k10k(SLOPED)(SLOPED)(SLOPED)(SLOPED)(SLOPED)(SLOPED)(SLOPED)(SLOPED)EOD8"RD01 RD01 S01 ROOF HATCH (SEE ARCH) +158' - 9 1/2" W21X62 +157' - 11 1/2"W14X224' - 0"7 EQ SPA = 35' - 0"5 EQ SPA = 25' - 0"7 EQ SPA = 35' - 0"2' - 6"4' - 0" NARROW PARAPET EXTENTS NARROW PARAPET EXTENTS 4 S410 W10X12W10X12 3' - 2"1' - 8 5/8"EOS TYP 4" 11,500LB RTU 11,500LB RTU 5' - 10"6' - 10"11' - 8"6' - 11 3/4"W10X12FUTURE CHASE5' - 2 1/8"8' - 7 7/8"W12X19W12X1910k10k10k10k 10k 10k10k10k10k 6' - 5"4' - 4"EOS 4" 7 7/8"4" EOS4" EOSEOS 5"+159' - 4"+159' - 4"W10X12+159' - 4"W14X22 +159' - 4" W14X22 +159' - 4" W12X16 +159' - 4"W8X10+159' - 4"W8X10+159' - 4"4' - 8"2' - 4 1/4"8"8" EOS4" EOSEOS 4" EOS 4" 15 S408 16 S408 MC18X42.7 BELOW MC18X42.7BELOW S01 SS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m Construction Manager: Civil Engineer: Owner: MIDTOWN EAST BLOCK 3 OFFICE 55 Monument Circle, Suite 450 Indianapolis, IN 46204 317-507-6067 F.A. WILHELM CONSTRUCTION COMPANY 3914 Prospect St. Indianapolis, IN 46203 317-359-5411 Civil & Environment Consultants, Inc. 560 E. Ohio Street Suite G Indianapolis, IN 46204 Structural Engineer: McComas Engineering 1717 East 116th Street Suite 200 Carmel, IN 46032 MEP Engineer: Freije 11800 Exit 5 Pkwy Suite 106 Fishers, IN 46037 PERMIT ISSUE 2017-04-24 571 Monon Blvd. Carmel, INKLS CRM 2017-02-27 S204 ROOF FRAMING PLAN MEI 17017MIDTOWN EAST BLOCK 3 OFFICESCALE: 1/8" = 1'-0" ROOF FRAMING PLAN FRAMING PLAN NOTES: 1. ELEVATIONS ±, ARE FROM NOMINAL FIRST FLOOR ELEV +100'-0", SEE CIVIL DRAWINGS. 2. SEE S401 FOR GENERAL NOTES. 3. SEE S402 FOR SCHEDULES. 4. SEE S403 FOR COLUMN SCHEDULE. 5. SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS NOT SHOWN. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION AND NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES IMMEDIATELY. 6. COORDINATE DECK OPENINGS - EXACT SIZE AND LOCATION, WITH MECHANICAL CONTRACTOR DRAWINGS AND EQUIPMENT SUPPLIER. PLAN NORTH 0 1'4'8'16'2' 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 # DESCRIPTION DATE 2 Addendum 02 2017-04-03 3 Addendum 03 2017-04-12 A B C D 1 2 3 4 5 6 7 8190' - 0"10' - 0"30' - 0"30' - 0"30' - 0"30' - 0"30' - 0"30' - 0"HSS12X12X1/4+170' - 0"+161' - 10"HSS12X12X1/4+170' - 0"+161' - 10"HSS12X12X1/4HSS12X12X1/4+170' - 0" +161' - 10"HSS12X12X1/4 HSS12X12X1/4+170' - 0"+161' - 10"HSS12X12X1/4HSS12X12X1/4+170' - 0"+161' - 10"HSS12X12X1/4HSS12X12X1/4HSS12X12X1/4HSS12X12X1/4+170' - 0"+161' - 10"HSS12X12X1/4HSS12X12X1/4+170' - 0"+161' - 10"HSS12X12X1/4HSS12X12X1/4HSS12X12X1/4HSS12X12X1/4+170' - 0"+161' - 10"+170' - 0"+161' - 10"HSS12X12X1/4 HSS12X12X1/4 +170' - 0" +161' - 10" 39' - 0"25' - 0"39' - 0" 1 S411 D.1 2 S411 2/ S501 1/ S5013/ S501 4 S410 105' - 6" 2' - 6"5' - 9 3/4"15 S408 16 S408 SS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m Construction Manager: Civil Engineer: Owner: MIDTOWN EAST BLOCK 3 OFFICE 55 Monument Circle, Suite 450 Indianapolis, IN 46204 317-507-6067 F.A. WILHELM CONSTRUCTION COMPANY 3914 Prospect St. Indianapolis, IN 46203 317-359-5411 Civil & Environment Consultants, Inc. 560 E. Ohio Street Suite G Indianapolis, IN 46204 Structural Engineer: McComas Engineering 1717 East 116th Street Suite 200 Carmel, IN 46032 MEP Engineer: Freije 11800 Exit 5 Pkwy Suite 106 Fishers, IN 46037 PERMIT ISSUE 2017-04-24 571 Monon Blvd. Carmel, INKLS CRM 2017-02-27 S205 SCREEN WALL FRAMING PLAN MEI 17017MIDTOWN EAST BLOCK 3 OFFICESCALE: 1/8" = 1'-0" SCREEN WALL FRAMING PLAN FRAMING PLAN NOTES: 1. ELEVATIONS ±, ARE FROM NOMINAL FIRST FLOOR ELEV +100'-0", SEE CIVIL DRAWINGS. 2. SEE S401 FOR GENERAL NOTES AND SCHEDULES. 3. SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS NOT SHOWN. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION AND NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES IMMEDIATELY. 4. COORDINATE DECK OPENINGS - EXACT SIZE AND LOCATION, WITH MECHANICAL CONTRACTOR DRAWINGS AND EQUIPMENT SUPPLIER. PLAN NORTH 0 1'4'8'16'2' 2 # DESCRIPTION DATE 2 Addendum 02 2017-04-03 014000 DELEGATED DESIGN SSE1.A Specialty Structural Engineer (SSE), registered in the state of the project, shall be responsible for the structural design of the following products and systems complying with specific performance and design criteria indicated. 1. Steel Joists, joist girders, bridging and accessories. 2. Structural Steel Connections, except as shown on drawings. AISC Option 2 (Detailer): Simple shear connections. AISC Option 3 (SSE): All other connections not shown. 3. Metal Stairs. 4. Cold-Formed Steel CFS trusses, CFS girders, CFS bracing and accessories. 5. Cold-Formed Steel CFS wall studs, CFS floor joists and accessories. SF1.Soil to be stripped, compacted and tested in accordance with the recommendations of the soils engineer and project specifications. SF2.Footings shall be placed on firm, undisturbed soil or on engineered fill. Engineered Fill: Naturally or artificially graded mixture of natural or crushed gravel, crushed stone, and natural or crushed sand; ASTM D 2940; with at least 90 percent passing a 1-1/2-inch sieve and not more than 12 percent passing a No. 200 sieve. SF3.Slabs shall be placed on compacted, free-draining, frost-free drainage course. Drainage Course: Narrowly graded mixture of washed crushed stone, or crushed or uncrushed gravel; ASTM D 448; coarse-aggregate grading Size 57; with 100 percent passing a 1-1/2-inch sieve and 0 to 5 percent passing a No. 8 sieve. All fill shall be compacted to a minimum dry density of 95% of the modified Proctor maximum dry density (ASTM-D1557), placed in 6" to 8" lifts. Pea gravel may not be used as fill. Utility trenches and excavations under the foundations or slabs shall meet the same requirements. See soils investigation report for further recommendations. SF4.Undercutting of the soil for foundation and/or slab placement may be required. These drawings do not indicate the entire scope of undercutting, fill or bad soil removal that may be required to attain the design soil bearing pressures. It is the responsibility of the contractor to obtain a soils investigation report, before bidding, to assess the extent of excavation and compaction that may be required to meet the design criteria. The contractor shall retain the services of a soils engineer to monitor all backfilling operations and to inspect footing bearing material. A report certified by the soils engineer shall be furnished to the architect/engineer verifying that all foundations were placed on a material capable of sustaining the design bearing pressures. SF5.If dewatering is required, sumps shall not be placed within the foundation excavation. SF6.Maintain a maximum slope between adjacent footing bearing elevations of 2 horizontal to 1 vertical. Maintain a 2 horizontal to 1 vertical slope next to existing foundations to avoid undermining foundations. SF7.No horizontal joints are permitted in any foundation. Vertical joints are permitted only in wall footings. SF8.Shallow foundations may be earth-formed where the excavation permits. If earth-forming is used, add 2" to the width and length of all foundations. SF9.The bottom of all foundations shall be a minimum of local frost depth below final grade. 020000 SHALLOW FOUNDATION AND SLAB ON GRADE NOTES RC1.All concrete shall have the following 28 day compressive strengths: STRENGTH LOCATION 3000 psi-0% AE All foundations and footings 4000 psi-6% AE Exterior slabs, piers, walls, columns, grade beams and concrete exposed to freezing 4000 psi-0% AE Interior slabs, fill for metal deck and all other interior concrete RC2.All reinforcing shall conform to the following concrete cover: COVER LOCATION 3"Foundations & Footings: All surfaces; Exterior Slabs: Bottom; Grade Beams & Trench Footings: All surfaces; All concrete cast against soil 2"Exterior Walls, All Piers & All Pilasters: All surfaces; Exterior Slabs: Top; All exterior concrete 1 1/2"Interior beams, columns & walls: All surfaces; All concrete not exposed to weather or in contact with ground 3/4"Interior slabs & Walls RC3.Welded Wire Fabric (WWF) for slabs and fill for metal deck shall be placed in the upper-third of the slab or fill. See details. RC4.All reinforcing steel shall be detailed, supplied and placed in accordance with ACI 315, ACI 318 and CRSI MSP-1. RC5.All reinforcing steel shall be shop fabricated and, where applicable, shall be wired together and conform to ASTM A-615, Grade 60. RC6.Chamfer edges of exposed concrete 3/4", unless noted otherwise. RC7.Contractor shall make four, 6"x12" test cylinders for each 50 cubic yards of concrete poured for each days operation. Break 1 at 7 days, 2 at 28 days and retain spare. RC8.All welded wire fabric shall conform to ASTM A185, Fy(min) of 65 ksi. All welded wire fabric laps shall be 8". RC9.All finished concrete, concrete formwork and falsework shall be in accordance with ACI 301. Contractor is solely responsible for the design and construction of all formwork, falsework and shoring. RC10.Provide sleeves for all openings in grade beams or walls to totally separate pipe from concrete. RC11.Foundations may be earth-formed where the excavation permits. If earth-forming is used, add 2" to the width, length & thickness of all foundations. RC12.Plastic Vapor Retarder: ASTM E 1745, Class A, not less than 10 mils (0.25 mm) thick, see specifications. Include manufacturer's recommended adhesive or pressure-sensitive joint tape. RC13.Fiber Reinforcement, if indicated on drawings, shall be 100% virgin polypropylene in collated, fibrillated form, complying with ASTM C 1116, minimum length of 3/4". Minimum dosage = 1.5 pounds per cubic yard. RC14.Adhesive Anchors and Adhesives Used for Reinforcing Anchorage: 1. The adhesive anchor system used for post-installed anchorage to concrete shall conform to the requirements of the most recently published ACI 355.4. 2. Adhesive anchors indicated are the Basis-of-Design. Approved equal meeting ACI 355.4 is permitted. 3. Bulk-mixed adhesives are not permitted. 4. Anchors shall be supplied as an entire system with manufacturer's recommendations adhered to. 5. Adhesive anchors shall be installed by qualified personnel trained to install adhesive anchors. 6. Installation of adhesive anchors horizontally or upwardly inclined shall be performed by personnel certified by the ACI/CRSI Adhesive Anchor Installer Certification program. 7 .Adhesive anchors installed in horizontal or upwardly inclined orientations shall be continously inspected during installation by an inspector specially approved for that purpose. RC15.Bonding agent for bonding fresh concrete to hardened concrete: ASTM C 1059/C 1059M, Type II, nonredispersible, acrylic emulsion or styrene butadiene. 033000 CAST IN PLACE CONCRETE NOTES (Foundations, Slabs & Walls) SS1.All structural steel shall conform to the following: W Shapes ASTM A992, Grade 50. Angles, Channels, Plates, Bars ASTM A36 (Fy=36 ksi) HSS Tubes ASTM A500, Grade B (Fy=46 ksi) HSS Pipes ASTM A500, Grade B (Fy=42 ksi) Anchor Rods ASTM F1554, Grade 36 SS2.All steel shall be detailed, fabricated and erected in accordance with: AISC 360 "Specification for Structural Steel Buildings", Allowable Strength Design (ASD) AISC 303 "Code of Standard Practice" SS3.If beam reaction is not indicated, design connection for minimum 10 k reaction. SS4 All bolted connections shall be made with 3/4" diameter, A325 bolts with nuts and washers, unless otherwise noted. All connections shall be shear bearing connections tightened to snug-tight condition, unless otherwise noted. SS5.All shop and field welds shall be made using E70 electrodes or equivalent. SS6.All headed concrete anchors shall be ASTM A108 (Fy=50 ksi), 3/4" diameter x 4" after welding, unless noted otherwise. SS7.Steel fabricator shall obtain the size and location of all openings for grilles, louvers, etc. before proceeding with the fabrication and erection of any required frames. SS8.Provide Heckman #129 and #130 channel slot and channel slot anchors at all columns that abut masonry walls, unless noted. SS9.Provide temporary bracing of the structure until all permanent lateral support is in place. SS10. Structure Stability: The entire roof and/or floor decking materials must be fully erected and connected to the supporting steel before temporary, erection bracing is removed. SS11.RD = Roof Drain location. Provide steel frame for drains. See other drawings for actual drain type, number, size, etc. Coordinate with drain contractor. 051200 STRUCTURAL STEEL NOTES SJ1.Provide all joists, bridging and accessories for the complete erection of joists in accordance with the current Steel Joist Institute "STANDARD SPECIFICATIONS AND LOAD TABLES FOR OPEN WEB STEEL JOISTS AND JOIST GIRDERS" and Underwriters Laboratories "STANDARD, FIRE TESTS OF BUILDING CONSTRUCTION AND MATERIALS". SJ2.Bridging shall be completely erected and joists aligned before any construction loads are placed on joists. SJ3.Do not weld bottom chord of joists to columns unless noted on drawings. SJ4.Install erection bolts at all joist girder to column and joist to column connections. SJ5.Where ballasted roofing is not shown on architectural drawings, provide uplift bridging at all joists as per "STANDARD SPECIFICATIONS AND LOAD TABLES FOR OPEN WEB STEEL JOISTS AND JOIST GIRDERS" for a net uplift load of 12 psf, unless noted or shown otherwise. 052100 STEEL JOIST NOTES MD1.All metal deck material, fabrication and installation shall conform to Steel Deck Institute" SDI SPECIFICATIONS AND COMMENTARY" and "CODE OF RECOMMENDED STANDARD PRACTICE", Current edition, unless noted. MD2.FASTENING DECK 1. Roof deck shall be welded using 5/8" diameter puddle welds, 36/4 pattern with (1) #10 TEK sidelap fastener unless otherwise shown in typical detail or indicated on drawings. 2. Floor deck shall be welded using 3/4" diameter puddle welds, 36/4 pattern unless otherwise shown in typical detail or indicated on drawings MD3.Provide TS 2 1/2x 2 1/2x 1/8 deck support, field welded to joist or beam at all deck span changes. MD4.Provide L3x3x1/4 deck support at all columns where required, unless noted. MD5.Provide 20 gauge cover plate at all roof deck span changes. MD6.Provide L3x3x1/4 at all unsupported edges of deck and around roof perimeter, unless otherwise noted. MD7.All deck shall be provided in a minimum of 3-span lengths where possible. 053100 STEEL DECK NOTES SF1.All cold formed steel framing shall be by Specialty Structural Engineer, see specifications. SF2.All design and construction of cold formed steel shall comply with the contract documents, referenced codes, standards, notes, layouts and the following American Iron and Steel Institute (AISI) documents, including all AISI referenced documents therein: S100-2007 Specification S200-2007 General Provisions S201-2007 Product Data S210-2007 Floor & Roof Systems S211-2007 Wall Stud Design S213-2007 Lateral Design with Suppliment No. 1 S212-2007 Header Design S214-2007 Truss Design SF3.Unless noted otherwise, provide the following minimum member sizes, unless larger size or lesser spacing is required: TYPE SIZE Exterior Wall Studs 600 S 162-54 Interior Load-Bearing Studs 600 S 162-54 SF4.All members and systems shall conform to the following maximum movements: TYPE LIVE INDEX MAXIMUM Exterior Wall Studs L/600 1/2" Interior Wall Studs L/240 1/2" Exterior cantilevered parapets L/300 1/2" Floor trusses and joists L/480 1" Roof trusses and joists L/360 1 1/2" SF5.The most stringent requirements shall govern in conflicts between specified codes and standards. SF6.All products shall have four-part identification code which identifies size, style and material thickness of each member. SF7.All materials shall conform with ASTM A1003, structural grade 33 or structural grade 50. SF8.Corrosion protection for all materials shall comply with ASTM A653. Minimum, hot-dipped galvanized coating weight for exterior walls and all roof materials shall be G90. All other materials shall be G60. SF9.Provide factory punchouts in all wall studs where required. SF10.Provide standard color coding for all products. SF11.Provide 1/2" ASTM F1554, Grade 36 hooked anchor bolts at all steel tracks, u.n.o. Anchor bolt spacing = 48" OC, u.n.o. Provide anchor bolt at 8" from the ends of all walls, u.n.o. SF12.For all non-load bearing studs, provide deflection clips isolating the stud from the primary structure. SF13.All track butt joints shall be anchored to a common structural element. SF14.Horizontal bracing of wall studs shall be provided at 6 feet on center maximum. SF15.Place joists and trusses directly over wall studs. SF16.Fastening of elements shall be self-drilling screws or welding of sufficient size to transfer required loads. All welding of galvanized steel shall be touched up with zinc-rich paint. Minimum thickness of material for welding is 54 mil. SF17.All screws shall be non-corrosive, No. 12-14 or larger. SF18.See architectural drawings for all non-structural stud requirements. SF19.All floor and roof trusses shall have a minimum flange width of 1 5/8". SF20.Floor and roof truss bottom chords shall be designed for 10 psf dead load, not in addition to design loading. SF19.Lateral Force Resisting System (LFRS) shall comply with forces indicated. Shearwalls shall be Type II, steel sheet. Coordinate shearwalls with holdowns and ties shown. 054000 COLD FORMED STEEL FRAMING NOTES (Delegated Design) M1.Minimum 28 day compressive strength of concrete masonry units shall be 2800 p.s.i. based on net area of the unit. Specified design compressive strength of masonry shall be f'm = 2000 p.s.i. All units for exterior walls, load-bearing walls and shear walls shall be normal weight block. M2.All mortar shall be Type S. No admixtures may used unless approved by architect/engineer. Mortar shall not be used for grouting cores or filling bond beams. M3.All block shall be laid in a running bond pattern. M4.Course grout shall be used were grouting is required. Slump shall be 8" +/- 1". Minimum grout compressive strength shall be 3000 p.s.i. M5.All reinforcing shall be ASTM A615 Grade 60 (Fy=60 ksi). Lap all reinforcing a minimum of 48 bar diameters. M6.Center vertical reinforcing in block cores, unless noted otherwise. M7.See architectural and specifications for all control joint locations. Reinforcing in bond beams shall be discontinuous at control joints. M8.Provide ladder type horizontal joint reinforcement at 16" o.c. Side rods and cross rods shall be #9 wire, galvanized, see specifications. Cut joint reinforcement at control joints. M9.Provide "L" bars at all bond beam corners as required. M10.Fill cores of block solid with grout two full courses below the bearing of all beams or lintels supported on masonry. M11.All attachments to block shall be made with Hilti HLC 1/2" diameter x 3" sleeve anchors, unless noted otherwise. Anchors shall be installed per manufacturer's recommendations. M12.See typical schedules for masonry and steel lintels not indicated on plans. M13.All masonry units below grade to be grouted solid. M14.Provide ties to all structural steel. M15.All interior, non-load bearing masonry walls over 12'-0" high, shall be supported on thickened slab as per typical detail. Wall vertical reinforcing shall be #5 @ 48" OC full height. Unless noted otherwise. M16.All cores with reinforcing steel shall be grouted solid, full height of wall. 042000 MASONRY AND REINFORCED MASONRY NOTES SM1.Modify soil bearing capacity using Rammed Aggregate Pier (RAP) techniques. SM2.Soil shall be modified to achieve the minimum allowable bearing capacity stated. SM3.See Gravity Column Reaction and Bracing Column Reaction tables for design reactions. SM4.Rammed Aggregate Piers shall be designed by approved contractor. SM5.Provide minimum of (3) rap at column footings. 312010 SOIL MODIFICATION RAMMED AGGREGATE PIER NOTES ROOF C&C DESIGN NET WIND PRESSURES STRENGTH DESIGN PRESSURES W (ULT) MAIN ROOF, ZONE PRESSURES (PSF) - FIG. 30.4-2A 1, 2, 3 10/1 -19/-29 -1 -25/-34 -25/-34 -29/-38 -29/-38 -17/-26 -2 -3 -1OH -2OH -3OH Location Zone Pressure WALLS C&C DESIGN GROSS WIND PRESSURES STRENGTH DESIGN PRESSURES W (ULT) LOCATION 31/-34 28/-30 28/-34 31/-42 STUDS UNIT PRESSURE Pressure Pressure Pressure 28/-30 28/-34 CURTAIN WALL SYSTEM ZONE 4 5 NOTES: 1. Pressure Zones are shown in ASCE 7-10. Refer to standard for proper zone. 2. Pressures shown are +/- internal pressure. 3. Values shown are for Wind Speed V (Ult_ = 120 psf 4. OH = Overhang 5. (-) Pressure is suction perpendicular to surface. 6. (+) Pressure is perpendicular to surface. G1.BUILDING CODES: Model Code:2012 International Building Code Local Code:2014 Indiana Building Code Model Code Standard:ASCE 7-10 Steel Standard:AISC 360-10, ASD 14th Edition Concrete Standard:ACI 318-11 Masonry Standard:ACI 530-11, ASD Wood Standard:AITC/APA/NDS Current Edition Risk Category:II, Normal Risk G2.ROOF DESIGN LOADS: Location Dead Live Snow Main 22 psf 20 psf 20 psf Mechanical Enclosure Roof 135 psf 20 psf 20 psf G3.FLOOR DESIGN LOADS: Location Dead Live Partition 2nd Floor Balcony 138 psf 100 psf 2nd Floor Office 88 psf 50 psf 15 psf 3rd & 4th Floor Balconies 132 psf 100 psf 3rd & 4th Floor Office 82 psf 50 psf 15 psf G4.SOIL DESIGN CRITERIA Allowable Net Bearing Pressure: Spread Footings:6,000 psf (Modified Soils) Wall Footings:6,000 psf (Modified Soils) Soil Density:125 pcf G5.SLAB ON GRADE Compacted Fill Thickness 6 inch Compaction Specification 95% Modified Proctor D-1557 G6.SNOW DESIGN CRITERIA Ground Snow Load, Pg:20 psf Flat Roof Snow Load, Pf:20 psf Importance Factor, Is:1.0 Exposure Factor, Ce:1.0 Partially Exposed Thermal Factor, Ct:1.0 Heated Structure Warm Slope Factor, Cs:1.0 G7.WIND DESIGN CRITERIA Wind Speed, Vult:115 mph ASD Wind Speed, Vasd:90 mph Enclosure Class:Enclosed Internal Pressure Coef., GCpi:0.18 G8.SEISMIC DESIGN CRITERIA Importance Factor:1.00 Mapped Spectral Response, Ss:0.146 Mapped Spectral Response, S1:0.081 Site Class:D Design Spectral Response, Sds:0.156 Design Spectral Response, Sd1:0.130 Seismic Design Category, SDC:B Overstrength Factor, Omega:3 Seismic Response Coef., Cs:0.052 Response Modification R:3 Unfactored Base Shear, V:5.2% W Analysis Procedure:Equivalent Lateral Force Analysis Basic SFRS:H. Steel Systems Not Specifically Designed for Seismic Resistance G9.Reactions and forces indicated are unfactored, Allowable Strength Design (ASD) loads. G10.If Drawings and specifications are in conflict, the most stringent restrictions and requirements shall govern. Contractor shall bring all discrepancies to the attention of the engineer immediately. G11.Verify all existing conditions prior to any construction or fabrication. If different than shown, notify engineer/architect immediately for modification of drawings. G12.All contractors are required to coordinate their work with all disciplines to avoid conflicts. The architectural, mechanical, electrical and plumbing aspects are not in the scope of these drawings. Therefore, all required materials and work may not be indicated. It is the contractor's responsibility to coordinate these drawings with all other construction documents. Refer to architectural drawings for all dimensions not shown on these drawings. Locations, sizes and numbers of all openings may not be completely indicated in the structural drawings. The respective contractor shall verify their work with all other disciplines. G13.The contract documents represent the structure only. They do not indicate the method of construction. The contractor shallprovide all measures necessary to protect the structure during construction. Such measures shall include, but not limited to, bracing, shoring, underpinning, etc. McComas Engineering is not responsible for the contractor's means, methods, techniques, sequences or safety procedures during construction. G14.Notes and details shall take precedence over general structural notes. Where no details or sections are shown, construction shall conform to similar work on the project. Typical sections and details may not be cut on the plans, but apply unless noted otherwise. G15.Provisions for future expansion: Vertical:None Horizontal:None GENERAL NOTES SS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m Construction Manager: Civil Engineer: Owner: MIDTOWN EAST BLOCK 3 OFFICE 55 Monument Circle, Suite 450 Indianapolis, IN 46204 317-507-6067 F.A. WILHELM CONSTRUCTION COMPANY 3914 Prospect St. Indianapolis, IN 46203 317-359-5411 Civil & Environment Consultants, Inc. 560 E. Ohio Street Suite G Indianapolis, IN 46204 Structural Engineer: McComas Engineering 1717 East 116th Street Suite 200 Carmel, IN 46032 MEP Engineer: Freije 11800 Exit 5 Pkwy Suite 106 Fishers, IN 46037 PERMIT ISSUE 2017-04-24 571 Monon Blvd. Carmel, INKLS CRM 2017-02-27 S401 GENERAL NOTES MEI 17017MIDTOWN EAST BLOCK 3 OFFICE# DESCRIPTION DATE SS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m Construction Manager: Civil Engineer: Owner: MIDTOWN EAST BLOCK 3 OFFICE 55 Monument Circle, Suite 450 Indianapolis, IN 46204 317-507-6067 F.A. WILHELM CONSTRUCTION COMPANY 3914 Prospect St. Indianapolis, IN 46203 317-359-5411 Civil & Environment Consultants, Inc. 560 E. Ohio Street Suite G Indianapolis, IN 46204 Structural Engineer: McComas Engineering 1717 East 116th Street Suite 200 Carmel, IN 46032 MEP Engineer: Freije 11800 Exit 5 Pkwy Suite 106 Fishers, IN 46037 PERMIT ISSUE 2017-04-24 571 Monon Blvd. Carmel, INKLS CRM 2017-02-27 S402 SCHEDULES MEI 17017MIDTOWN EAST BLOCK 3 OFFICECONCRETE WALL SCHEDULE Mark Width Horiz Reinf Vert Reinf Dowel Reinf Reinf Location Cover RemarksSize Spa Location Size Spa Size Spa CW8 8" #4 1' - 0" Outside Face #4 1' - 0" #4 1' - 0" Center CW10 10" #5 1' - 0" Outside Face #5 1' - 0" #5 1' - 0" Center CW14 1' - 2" #5 1' - 0" Outside Face #5 1' - 0" #5 1' - 0" Ea Face CW24 2' - 0" #5 8" Outside Face #5 1' - 0" #5 1' - 0" Ea Face ELEVATED SLAB SCHEDULE Mark Total Thickness Concrete Density Conc Reinf Metal Deck RemarksThickness Gauge Type Finish S01 4" Normal Weight 6x6-W1.4xW1.4 WWF 2" 20 Composite Galvanized S02 6" Normal Weight 6x6-W2.1xW2.1 WWF 2" 20 Composite Galvanized MAT FOUNDATION SCHEDULE Mark Thickness Bottom Reinforcing Top Reinforcing Remarks Short Direction Long Direction Short Direction Long Direction Size Spa Size Spa Size Spa Size Spa MAT01 1' - 0" #5 1' - 0" #5 1' - 0" #5 1' - 0" #5 1' - 0" ROOF DECK SCHEDULE Mark Thickness Gauge Type Finish Sidelap Remarks RD01 1 1/2" 22 WR Painted (2)#10 TEK RD02 1/4" 1/4" Steel Plate See Arch 1/4" dia bolts @ 12" OC SLAB ON GRADE SCHEDULE Mark Thickness Reinforcing Control Jt Depth Reinf Clearance Control Jt Spa Vapor Retarder Sub-Base Depth Remarks SOG04P 4" 6x6-W1.4xW1.4 WWF 1" 1 1/2" 13' - 0" Plastic 6" WALL FOOTING SCHEDULE Mark Dimensions Bottom Reinf RemarksWidth Thickness Longitudinal Reinf Transverse Reinf No Size Size Spa WF24 2' - 0" 1' - 0" 3 #5 NA 0" WF30 2' - 6" 1' - 0" 3 #5 NA 0" WF48R 4' - 0" 1' - 4" 6 #5 NA 0" O/O OUT TO OUT OA OVERALL OC ON CENTER OD OUTSIDE DIAMETER OF OUTSIDE FACE OH OVER HEAD OPNG OPENING OPP OPPOSITE OPP HD OPPOSITE HAND OSB ORIENTED STRAND BOARD OSL OUTSTANDING LEG OVS OVERSIZE HOLE PAF POWDER ACTUATED FASTENER PC PRECAST PL PLATE PLF POUNDS PER LINEAR FOOT PLYWD PLYWOOD PNL PANEL PROJ PROJECTION PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PSL PARALLEL STRAND LUMBER PT PRESSURE TREATED PTN PARTITION R RADIUS RD ROOF DRAIN REF REFERENCE REINF REINFORCE(D) (ING) (MENT) REQ'D REQUIRED REV REVISION/REVISED RO ROUGH OPENING RRD ROOF RELIEF DRAIN RTN RETURN RTU ROOF TOP UNIT RW RETAINING WALL SCHED SCHEDULE SECT SECTION SHT SHEET SIM SIMILAR SJ SAWCUT JOINT SJI STEEL JOIST INSTITUTE SL SLOPED SPA SPACE(S) SPECS SPECIFICATIONS SQ SQUARE SS STAINLESS STEEL SSL SHORT SLOTTED HOLES STD STANDARD STIFF STIFFENERS STL STEEL STRUCT STRUCTURAL SYMM SYMMETRICAL T&B TOP AND BOTTOM T&G TONGUE AND GROOVE TB TIE BEAM TC TOP CHORD TCX TOP CHORD EXTENSION TEMP TEMPERATURE TF TRENCH FOOTING THK THICK THKS THICKENED SLAB THR'D THREADED TL TOTAL LOAD TOP'G TOPPING TRANS TRANSVERSE TYP TYPICAL UNO UNLESS NOTED OTHERWISE VERT VERTICAL VIF VERIFY IN FIELD w/WITH WD WOOD WO WINDOW OPENING (MASONRY) WP WORKING POINT WT WEIGHT WWF WELDED WIRE FABRIC ELEVATION TOP AND BOTTOM OF LIST T/"ELEVATION, TOP OF" B/"ELEVATION, BOTTOM OF" T/BB TOP OF BOND BEAM T/BM TOP OF BEAM T/CONC TOP OF CONCRETE T/F TOP OF FOOTING T/LDG TOP OF LEDGE T/MAS TOP OF MASONRY T/P TOP OF PIER T/SLAB TOP OF SLAB T/STL TOP OF STEEL T/W TOP OF WALL T/GB TOP OF GRADE BEAM T/CAIS TOP OF CAISSON B/PL BOTTOM OF PLATE B/F BOTTOM OF FOOTING SPECIAL CHARACTERS °DEGREE ±PLUS OR MINUS ELEVATION Ø DIAMETER AR ANCHOR RODS ABV ABOVE ACI AMERICAN CONCRETE INSTITUTE ADD'L ADDITIONAL ADH ADHESIVE ADJ ADJACENT AESS ARCHITECTURALLY EXPOSED STRUCTURAL STEEL AFF ABOVE FINISHED FLOOR AGGR AGGREGATE AHU AIR HANDLING UNIT AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION AISI AMERICAN IRON AND STEEL INSTITUTE ALUM ALUMINUM ALT ALTERNATE APPROX APPROXIMATE ARCH ARCHITECT ARCH'L ARCHITECTURAL ASTM AMERICAN SOCIETY OF TESTING MATERIALS AWS AMERICAN WELDING SOCIETY L ANGLE BAL BALANCE BB BOND BEAM B/B BACK TO BACK BC BOTTOM CHORD BD BOARD BLDG BUILDING BLK BLOCK BLW BELOW BM BEAM BOTT BOTTOM BP BEARING PLATE BRDG BRIDGING BRG BEARING BRK BRICK BS BOTH SIDES BSMT BASEMENT BTWN BETWEEN BUC BUILT UP COLUMN c CAMBER C/C CENTER TO CENTER CANT CANTILEVER CAIS CAISSON CFS COLD FORMED STEEL CJ CONTROL AND/OR CONSTRUCTION JOINT CL CENTERLINE CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN COORD COORDINATE COMP COMPACTED CONC CONCRETE CONN CONNECTION CONST CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CTR CENTER CTR'D CENTERED DIA DIAMETER DIAG DIAGONAL DIM DIMENSION DL DEAD LOAD DLT DEEP LEG TRACK DO DITTO DN DOWN DTL DETAIL DWG DRAWING DWL DOWEL EA EACH EE EACH END EF EACH FACE EJ EXPANSION JOINT ENG ENGINEER ELEV ELEVATION ELECT ELECTRICAL EOD EDGE OF DECK EOS EDGE OF SLAB EQ EQUAL EQUIV EQUIVALENT ES EACH SIDE EW EACH WAY EXIST EXISTING EXP EXPANSION EXT EXTERIOR F/FACE OF FD FLOOR DRAIN FDN FOUNDATION FIN FINISH FLR FLOOR FLG FLANGE FS FARSIDE FTG FOOTING GA GAUGE GALV GALVANIZED GB GRADE BEAM GC GENERAL CONTRACTOR GL GLULAM GR GRADE HC HOLLOW CORE HD HOLD DOWN HGT HEIGHT HI HIGH HK HOOK HORIZ HORIZONTAL HP HIGH POINT HS HEADED STUD HSS HOLLOW STRUCTURAL SECTION ID INSIDE DIAMETER IF INSIDE FACE INFO INFORMATION INT INTERIOR INV INVERT JST JOIST JT JOINT K KIP KO KNOCK OUT LB POUND LDG LEDGE LG LONG LL LIVE LOAD LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LNTL LINTEL LSL LONG SLOTTED HOLES LONG LONGITUDINAL LP LOW POINT LVL LAMINATED VENEER LUMBER MAS MASONRY MAT'L MATERIAL MAX MAXIMUM MBM METAL BUILDING MFR MCJ MASONRY CONTROL JT MECH MECHANICAL MEZZ MEZZANINE MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MO MASONRY OPENING MOM MOMENT MSW MASONRY SHEAR WALL MSL MEAN SEA LEVEL MTL METAL NO NUMBER NS NEAR SIDE NTS NOT TO SCALE ABBREVIATIONS LIST Wall Footing Schedule Notes: 1. Reinforcing clearance at bottom and sides of footings = 3" 2. Use concrete brick of CRSI Class 3, CHCP wire bar supports @ 36". Column Footing Schedule Notes: 1. Reinforcing clearance at bottom and sides of footings = 3" 2. Use concrete brick of CRSI Class 3, CHCP wire bar supports @ 36". Concrete Wall Schedule Notes: 1. Provide concrete cover to closest bar as indicated. 2. Provide wheel spacers or CRSI Typ. Bar Bend T5 at 36" each way to assure adequate concrete cover. 3. See sections for all bars not included in schedule. 4. Horizontal Bar Location: In = Horiz. bars inside of verical bars, Out = Horiz. Bars outside of vert. bars. Roof Deck Schedule Notes: 1. Abbreviations: WR = Wide Rib WRC = WR Cellular WRA = Wide Rib Acoustical WRAC = Wide Rib Acoustical Cellular Non-Inter = Non-interlocking sidelap Interlock = Interlocking sidelap 2. Provide minimum of 1 1/2" bearing at ends of deck. 3. Provide minimum of 4" interior bearing. Elevated Slab Schedule Notes: 1. Provide minimum of 1 1/2" end bearing. 2. Total thickness is the thickness from top of concrete to bottom of deck. 3. If indicated, provide minimum galvanized finish equal to ASTM A653-G30. 4. Fasten sidelaps with #10 tek screws or button punch (1 per span min). WALL CONSTRUCTION OR CONTROL JOINT SPACING THICKNESS MAX SPACING 8" 10" 12" 16" 24" 12'-0" 14'-0" 16'-0" 25'-0" 30'-0" Slab on Grade Schedule Notes: 1. Reinforcing clearance is from the top of slab. COLUMN FOOTING SCHEDULE Mark Ftg Dimensions Bottom Reinforcing RemarksWidth Lengt h Thickness Short Direction Long Direction No Size Length No Size Length F4 4' - 0" 4' - 0" 1' - 4" 5 #5 3' - 6" 5 #5 3' - 6" TOP & BOTTOM F5 5' - 0" 5' - 0" 1' - 4" 6 #5 4' - 6" 6 #5 4' - 6" F6 6' - 0" 6' - 0" 1' - 8" 9 #5 5' - 6" 9 #5 5' - 6" F7 7' - 0" 7' - 0" 2' - 0" 12 #5 6' - 6" 12 #5 6' - 6" F8 8' - 0" 8' - 0" 2' - 2" 11 #6 7' - 6" 11 #6 7' - 6" F9 9' - 0" 9' - 0" 2' - 4" 13 #6 8' - 6" 13 #6 8' - 6" F3812 12' - 0" 38' - 0" 2' - 8" 39 #8 11' - 6" 18 #8 37' - 6" TOP & BOTTOM F4516 16' - 0" 45' - 0" 3' - 6" 46 #9 15' - 6" 17 #9 44' - 6" TOP & BOTTOM Mat Foundation Schedule Notes: 1. Reinforcing clearance at bottom and sides of mats = 3" 2. Use concrete brick of CRSI Class 3, CHCP wire bar supports @ 36". PIER SCHEDULE Mark Pier Size Vert Reinf Ties RemarksWidth Length No Size Size Spa Tie Type P20 1' - 8" 1' - 8" 4 #7 #3 1' - 0" SEE NOTES P28 2' - 4" 2' - 4" 8 #7 #3 1' - 0" SEE NOTES P40 3' - 4" 3' - 4" 16 #7 #4 1' - 0" SEE NOTES P5252 4' - 4" 4' - 4" 20 #7 #4 1' - 0" SEE NOTES Pier Schedule Notes: 1. Provide 2 inch concrete cover over ties. 2. Space first tie 2" from top of footing, last tie 2" from top of pier. 3. Provide (3) ties in top of pier, spacing = 2 1/2" on center. 4. Provide CRSI typical bar bend T5 for all ties. 5. Provide CRSI typical bar bend T9 additional ties for all piers with more than four vertical bars. 6. Provide 90° Hook for all ties per CRSI detailing standards.. BRICK LINTEL SCHEDULE FOR ALL LINTELS NOT INDICATED ON PLANS Clear Opening Steel Angle Up to 5'-0" Brick Lintel Schedule Notes: 1. All lintels shall have 8" bearing on each end of opening. 2. All exterior lintels shall be galvanized. 3. All interior lintels shall be shop primed with two coats of epoxy/urethane coating system. L3 1/2 x 3 1/2 x 5/16 5'-1" up to 7'-0" L5 x 3 1/2 x 5/16 (LLV) 7'-0" up to 10'-0" L6 x 3 1/2 x 3/8 (LLV) 2 # DESCRIPTION DATE 2 Addendum 02 2017-04-03 T/Slab Fdn T/Slab Fdn 100' - 0"100' - 0" T/Slab 2nd Flr T/Slab 2nd Flr 116' - 0"116' - 0" T/Slab 3rd Flr T/Slab 3rd Flr 130' - 0"130' - 0" Column Splice Column Splice 134' - 0"134' - 0" T/Slab 4th Flr T/Slab 4th Flr 144' - 0"144' - 0" T/Stl Roof T/Stl Roof 158' - 9 1/2"158' - 9 1/2" T/Stl Screen Wall T/Stl Screen Wall 170' - 0"170' - 0" Column Locations A-1, A-7, D-7 A-2, A-5, A-6, B-1, B-8, C-1, C-8, D-4, D-5, D-6 A-3, A-4 A-8, D-8 B-2, B-3, C-2 B-4, C-4 B-5, C-5 B-6, C-6 B-7, C-7 C-3 D.1-1 D.1-2, D.1-3 E-3.6, F-3.4, F-3.6W12X53W12X65W12X65W12X45W12X96W12X72W12X72W12X72W12X72W12X79W12X53W12X72W12X40W12X40W12X53W12X40W12X45W12X45W12X45W12X53W12X40W12X45W12X40W12X40HSS12X12X3/8HSS12X12X3/8HSS12X12X3/8HSS12X12X3/8HSS12X12X3/8ANCHOR RODSBASE PLATE(4) 1"Ø1 5/8" x 1' - 8" x 1' - 8"ANCHOR RODSBASE PLATE(4) 1"Ø1 5/8" x 1' - 8" x 1' - 8"ANCHOR RODSBASE PLATE(4) 1"Ø1 5/8" x 1' - 8" x 1' - 8"ANCHOR RODSBASE PLATE(4) 1"Ø1 5/8" x 1' - 8" x 1' - 8"ANCHOR RODSBASE PLATE(4) 1"Ø1 5/8" x 1' - 8" x 1' - 8"ANCHOR RODSBASE PLATE(4) 1"Ø1 5/8" x 1' - 8" x 1' - 8"ANCHOR RODSBASE PLATE(4) 1"Ø1 5/8" x 1' - 8" x 1' - 8"ANCHOR RODSBASE PLATE(4) 1"Ø1 5/8" x 1' - 8" x 1' - 8"ANCHOR RODSBASE PLATE(4) 1"Ø1" x 1' - 2" x 1' - 2"ANCHOR RODSBASE PLATE(4) 1"Ø1 5/8" x 1' - 8" x 1' - 8"HSS6X6X3/81' - 0"TYPICAL WIDE FLANGE COLUMN SPLICE 1/2" PLATE x 10" WIDE AT W10 & W12 1/2" PLATE x 12" WIDE AT W14 3/4"Ø A325-N BOLTS (10) REQ'D EA FLANGE PROVIDE FILLS AS REQUIRED FINISHFINISH0 0 (TENSION SPLICE CONNECTION DESIGNATED BY FABRICATOR)8"8"1' - 0"1' - 4"1' - 6"1/2"Ø 3/4"Ø or 7/8"Ø 1"Ø 1 1/8"Ø or 1 1/4"Ø 1 1/2"Ø or 2"Ø ANCHOR ROD ANCHOR ROD ANCHOR ROD ANCHOR ROD ANCHOR ROD T/SLAB, PIER WALL OR FTG 8" FOR CONCRETE6" FOR MASONRYPL 3/4"x4"x4" w/ NUT PL 3/4"x4"x4" w/ NUT NOTES: 1. SEE SCHEDULE OR SECTIONS FOR REQUIRED ANCHOR ROD SIZE AND SPACING. 2. PROVIDE NUTS AND WASHERS FOR ALL ANCHOR RODS. 3"3" 1' - 4"SEE SCHEDULE 1' - 4"SEESCHEDULEPLAN 3/4"Ø ANCHOR ROD DOUBLE NUT GROUT HEIGHT 7/8"Ø 1"Ø 1 1/8"Ø 1 1/4"Ø 1 1/2"Ø 2"Ø 1 1/16"Ø3/4"Ø ANCHOR ROD HOLE DIAMETER 1 3/16"Ø7/8"Ø 1 1/2"Ø1"Ø 1 5/8"Ø1 1/8"Ø 1 3/4"Ø1 1/4"Ø 2"Ø1 1/2"Ø 2 1/2"Ø2"Ø 3"Ø2 1/2"Ø EDGE DISTANCE 1 1/2" 1 3/4" 2" 2 1/4" 2 1/2" 3" 4" 4 1/2"3"2 1/2"Ø 3" 2" 2" 2" 2" 2" 2" BASE PLATE - SEE SCHEDULE COLUMN 1/4" LEVELING PLATE 3/4" NON-SHRINK, NON- METALLIC GROUT (IF DOUBLE NUTS ARE NOT USED) DOUBLE NUTS - NO LEVELING PLATE REQ'D - SEE SCHEDULE FOR GROUT HEIGHT ANCHOR RODS 1/2 1 1/2"x20"x20" BASE PLATE T/SLAB +(SEE PLAN) 5/16 5/16 1 1/2"x20"x20" BASE PLATE 2" HSS COLUMN (8) 3/4"Ø A325 BOLTS (3 PER SIDE) 1" THICK THERMAL BREAK MAT'L (FABREEKA-TIM OR EQUAL) W COLUMN C 7 3' - 6" 3"1' - 0"1' - 0"1' - 0"3"3"1' - 6"3"2' - 0"2 1/2" BASE PLATE w/ (8) 1-1/2"x24" EMBEDMENT ANCHOR RODS CW24 10"CL PLATE & PIER OFFSET P5252 (10) #6 HOOKED BARS @3" OC VERT CONT TO GRID B THROUGH CW24 (2) LAYERS OF (6)#6 TIES @ 2" AT T/ PIER (2) LAYERS OF (5)#6 TIES @ 2" AT T/ PIER B 7 1/2 PL 2 3/4"x2'-0"x2'-0" w/ (6) 1 1/2" x2'-0" EMBEDMENT ANCHOR RODS 3"9"9"3"3"9"9"3"2' - 0"2' - 0" C 2 1' - 7"11" 2' - 6" 3"2' - 0"3"2' - 0"3"9"9"3"3" SHEAR LUG 3"x5"x1'-2"2 1/2"x2'-2"x2'-10" BASE PLATE w/ (8) 1 1/2"Ø AB 5/16 4" 2' - 0" BP OFFSET SEE 5/S403 FOR PIER AND WALL SPECIAL REINFORCEME NTS B 2 2 3/4" BASE PLATE w/() 1 1/2" x 30" EMBEDMENT ANCHOR RODS3"1' - 4"1' - 8" 3' - 6"3' - 6"3"7 1/4"7 1/4"5 1/2"8"8"3"B 3 3' - 6"3"1' - 6"3" 2' - 0" 2 3/4" BASE PLATE w/ (2) 1 1/2" x 30" EMBEDMENT ANCHOR RODS 10"CL PLATE & PIER OFFSET CW24 P5252 SEE 5/S403 FOR SPECIAL PIER & WALL REINFOCEMENT INFORMATION 3"(5) EQ3"SS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m Construction Manager: Civil Engineer: Owner: MIDTOWN EAST BLOCK 3 OFFICE 55 Monument Circle, Suite 450 Indianapolis, IN 46204 317-507-6067 F.A. WILHELM CONSTRUCTION COMPANY 3914 Prospect St. Indianapolis, IN 46203 317-359-5411 Civil & Environment Consultants, Inc. 560 E. Ohio Street Suite G Indianapolis, IN 46204 Structural Engineer: McComas Engineering 1717 East 116th Street Suite 200 Carmel, IN 46032 MEP Engineer: Freije 11800 Exit 5 Pkwy Suite 106 Fishers, IN 46037 PERMIT ISSUE 2017-04-24 571 Monon Blvd. Carmel, INKLS CRM 2017-02-27 S403 COLUMN SCHEDULE MEI 17017MIDTOWN EAST BLOCK 3 OFFICE(GALV)(GALV)(GALV)(GALV)SCALE:S403 3/4" = 1'-0" 1TYPICAL COLUMN SPLICE DETAIL SCALE:S403 3/4" = 1'-0" 2TYPICAL ANCHOR ROD DETAILS SCALE:S403 3/4" = 1'-0" 3COLUMN BASE DETAIL (FRAME COL)(FRAME COL)(FRAME COL)(FRAME COL)ANCHOR RODS:(SEE DETAIL)BASE PLATE:(SEE DETAIL)ANCHOR RODS:(SEE DETAIL)BASE PLATE:(SEE DETAIL)NOTE: BOTTOM OF BASE PLATE ELEVATION = TOP OF FOOTING OR PIER ELEVATION + 2" (SEE PLAN FOR FOOTING AND PIER ELEVATIONS) SCALE:S403 3/4" = 1'-0" 4TYP COLUMN SPLICE @ ROOF SCALE:S403 3/4" = 1'-0" 5BASE PLATE SCALE:S403 3/4" = 1'-0" 6BASE PLATE SCALE:S403 3/4" = 1'-0" 7BASE PLATE SCALE:S403 3/4" = 1'-0" 8BASE PLATE SCALE:S403 3/4" = 1'-0" 9BASE PLATE # DESCRIPTION DATE T/CONC -0'-2" T/CONC -0'-2" T/CONC -0'-0" T/CONC -0'-10" T/CONC -0'-0"SLOPEEXTERIOR SLAB SEE CIVIL THICKENED SLAB CONSTRUCTION OR CONTROL JT EXTERIOR SLAB SEE CIVIL GFKJ A J CARCH SEEARCHSEE CMU/CONC WALL CMU WALL CONC RAMP SLAB DEPRESSION OPENING IN SLAB SEE DETAIL H LOWER SLAB COLUMN ISOLATION SEE DETAIL D COLUMN ISOLATION SEE DETAIL E SLAB ON GRADE BTYPICAL SLAB ON GRADE KEY PLAN SCALE: NTS NOTE: KEY PLAN ILLUSTRATES CONSTRUCTION CONCEPTS ONLY. SEE PLAN FOR ACTUAL DIMENSIONS AND ARRANGEMENTS. SOG01 SLAB MARK SEE SCHEDULE 2' - 0"2' - 0"POUR SLAB, LEAVING OUT AREA AROUND COLUMN. INFILL WITH CONCRETE AFTER SLAB HAS CURED 1/2" EXP JT MAT'L COLUMN SLAB CONTROL JT, TYP AT ALL COLUMN LINES VAPOR RETARDER CONC SLAB COMPACTED SUB GRADE COMPACTED GRANULAR FILL T/SLAB +(SEE PLAN) FORMED KEY VAPOR RETARDER CONC SLAB COMPACTED SUB GRADE COMPACTED GRANULAR FILL T/SLAB +(SEE PLAN) 1/8" SAW N CONTROL JOINT, ALL JOINTS SHALL BE SAWN WITHIN 12 HOURS OF SLAB POUR 4" 13'-0" 1" 5" 15'-0" 1 1/4" 6" 15'-0" 1 1/2" 7" 18'-0" 1 3/4" 8" 20'-0" 2" 9" 24'-0" 2 1/4" 10" 25'-0" 2 1/2" 1'-0" 25'-0" 3" SLAB THICKNESS MAX JT SPACING JOINT DEPTH NOTE: CONTRACTOR TO PROVIDE CONTROL JOINT LAYOUT, BASED ON MAXIMUM JOINT SPACING, UNO. POUR SLAB, LEAVING OUT AREA AROUND COLUMN. INFILL WITH CONCRETE AFTER SLAB HAS CURED 1/2" EXP JT MAT'L COLUMN SLAB CONTROL JT, TYP AT ALL COLUMN LINES2' - 0"TYPCONC PIER (BELOW) FOUNDATION WALL, SEE FOUNDATION PLAN FOR ACTUAL CONDITION THICKEND PORTION OF SLAB TO BE TWICE THE SLAB THICKNESS CALLED OUT ON THE PLANS(3) #5 CONT REINF ALL INTERIOR MASONRY WALLS OVER 12'- 0" HIGH w/ #5 @ 4'-0" OC, UNO 3' - 0" x#5 DOWELS, UNO1'-0"3'-0"8" MIN SEE PLANSEE PLANSLAB THICKNESSDEPRESSION UP TOT/SLAB +(SEE PLAN) WWF TO CONT THRU DEPRESSED SLAB AREA SEE PLAN FOR LIMITS COMPACTED DRAINAGE FILL PERIMETER INSULATION - SEE ARCH CONC SLAB 1/2" EXP JT MAT'L @ THRESHOLD INTERIOR SLAB EXTERIOR SLAB SLOPE1/4"GRANULAR FILL T/SLAB +(SEE PLAN) T/W +(SEE PLAN) x#5 @ 48" OC1'-6"1'-6"PERIMETER INSULATION - SEE ARCH CONC SLAB 1/2" EXP JT MAT'L INTERIOR SLAB EXTERIOR SLAB SLOPE1/4"GRANULAR FILL T/SLAB +(SEE PLAN) T/W +(SEE PLAN) x#5 @ 48" OC1'-6"1'-6"#5x3'-0" @ 12" OC (3) PER DOOR MINTHAN PLAN THICKNESSDEPRESSION GREATERSEEP PLANSEE PLANT/SLAB +(SEE PLAN) x#3 @ 12" OC 9" 9"CONC SLAB #3 CONT COMPACTED DRAINAGE FILL CONC SLAB 2 1 T/SLAB +(SEE PLAN) 8" MIN T/SLAB +(SEE PLAN) T/SLAB +(SEE PLAN) 1/2" EXP JT MAT'L CONC SLAB CMU/CONC WALL 8" TYP 1' - 0" TYP THICKNESS2x SLAB1' - 0" TYP 8" TYP THICKNESS2x SLABT/STL +(SEE PLAN) T/STL +(SEE PLAN) CONC SLAB KEY METAL CONSTUCTION JOINT COMPACTED DRAINAGE FILL CONC SLAB KEY METAL CONSTUCTION JOINT TYP SLAB CONSTRUCTION JT TYP SLAB CONTROL JT SCALE: TYPICAL CONCRETE SLAB JOINTS NTS A SCALE: TYPICAL THICKENED SLAB NTS B SCALE: TYP CONCRETE RAMP DETAILS NTS C TOP OF RAMP BOTTOM OF RAMP SCALE: TYP COLUMN ISOLATION JOINT NTS D SCALE: TYP COLUMN ISOLATION JOINT NTS E SCALE: TYP SECTION AT ENTRY NTS F SCALE: TYP SECTION AT EXTERIOR SLAB NTS G SCALE: TYP DEPRESSED SLAB SECTIONS NTS J SECTION SECTION SCALE: TYP EXPANSION JT AT WALL NTS K ADDITIONAL #4x1'-6" @ EACH CORNER ADDITIONAL (4) #4x1'-6" OPENING IN SLAB 1 1/2" CLR (TYP)LIMITS OF SLAB REINFORCING SCALE: TYP SLAB ON GRADE OPENING NTS H NOTE: COORD LOCATION OF THRESHOLD w/ ARCH DWGS T/STL +(SEE PLAN) POCHE REPRESENTS MASONRY WALL P16 F4 P16 F4 T/P -0'-8" T/F -2'-8"HSS6MW8 T/W -0'-8"WF24 T/F -2'-8"CW8 T/W -0'-8" WF24 T/F -2'-8" COL MARK, SEE SCHEDULE FOR ACTUAL SIZE, BASEPLATE AND ANCHOR RODS P16 = PIER MARK, SEE SCHEDULE T/P = TOP OF PIER ELEV F4 = COL FTG MARK, SEE SCHEDULE T/F = TOP FTG ELEV CONCRETE MASONRY UNIT WALL (MW) SEE SCHED FOR SIZE AND REINF T/W = TOP OF WALL ELEV CONCRETE WALL (CW), SEE SCHED FOR WALL THICKNESS AND REINFSPOT ELEV INDICATES TOP OF CONC INDICATES PLAN DETAIL COL GRID, COLUMNS CENTERED ON GRID INTERSECTION, UNO T/F = TOP OF FTG ELEV CONCRETE WALL FTG (WF), SEE SCHED FOR SIZE AND REINF INDICATES SECTION CUT POCHE REPRESENTS CONCRETE WALL1 S401 2 S401 INDICATES EDGE OF WALL FTG INDICATES EDGE OF WALL FTG UNDER FLOOR SLAB 12 H G 12 D C B 11 INDICATES PLAN DETAIL INDICATES SECTION CUT 1 S401 2 S401 COL GRID, COLUMNS CENTERED ON GRID INTERSECTION, UNO 4"EODEDGE OF DECK, PERIMETER ANGLE W14x22 +23'-0" +23'-0" OPENING THRU DECK AND FRAMING W14x22 (SL)+24'-0"W14x22 +24'-0"TOP OF STEEL ELEV AT GRID INTERSECTION UNFACTORED REACTION IN KIPS TOP OF STEEL ELEV INDICATES BEAM SIZE JOIST SIZE32LH12 INDICATES KNEE BRACE KB18k18kINDICATES BRACING W14x22 +24'-0" MOMENT CONNECTION "X" BRIDGING HORIZ BRIDING 36G8N11.5K +24'-0"JOIST GIRDER SIZE (UNFACTORED) T/JOIST GIRDER ELEV 18K5INDICATES JOIST SIZE INDICATES BEAM SIZE NUMBER OF SHEAR STUDS BEAM CAMBER INDICATES BRACING ELEVATION5/8"W12x14 (9) C=3/4"INDICATES DECKSPAN AND DECKMARKS501 2 SS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m Construction Manager: Civil Engineer: Owner: MIDTOWN EAST BLOCK 3 OFFICE 55 Monument Circle, Suite 450 Indianapolis, IN 46204 317-507-6067 F.A. WILHELM CONSTRUCTION COMPANY 3914 Prospect St. Indianapolis, IN 46203 317-359-5411 Civil & Environment Consultants, Inc. 560 E. Ohio Street Suite G Indianapolis, IN 46204 Structural Engineer: McComas Engineering 1717 East 116th Street Suite 200 Carmel, IN 46032 MEP Engineer: Freije 11800 Exit 5 Pkwy Suite 106 Fishers, IN 46037 PERMIT ISSUE 2017-04-24 571 Monon Blvd. Carmel, INKLS CRM 2017-02-27 S404 SOG LEGEND MEI 17017MIDTOWN EAST BLOCK 3 OFFICESCALE: NTS FOUNDATION PLAN LEGEND SCALE: NTS FRAMING PLAN LEGEND # DESCRIPTION DATE 2" CLR 2" CLR2" CLR2" CLR1 1/2" CLR (TYP)SEE PLANPIER (P) PIER REINF - SEE SCHEDULE CONC WALL (CW) CONT WALL REINF THROUGH PIER WIDTH EQ EQ LENGTHEQ EQ PIER POURED INTEGRAL w/ WALL COLUMN ANCHOR RODS WITHIN TIES CONC PIER PIER VERT REINF SEE SCHEDULE CONC FTG T/P +(SEE PLAN)2"2"3"2' - 8 3/4"#3 TIES @ 12" OC1' - 10"1' - 10"SEE PLAN SEE PLAN2" CLRPIER VERT REINF SEE SCHEDULE TIE A SECTION A T/F -(SEE PLAN) PLACE TIE IN FTG FOR DOWEL ALIGNMENT 2 1/4"1' - 10"1' - 10"SEE PLAN SEE PLAN2" CLRPIER INTEGRATED w/ WALL1 3/4"WALL HORIZ CONT THROUGH PIER REINF COLUMN CONC FTG (F) T/F -(SEE PLAN) PLACE TIE IN FTG ALIGNMENT CONC SLAB w/ BLOCKOUT AT COLUMN T/SLAB -(SEE PLAN) T/F +(SEE PLAN) T/F +(SEE PLAN) 1' - 0" MATCH FOOTING REINF IN SIZE AND NUMBER REQ'D 2'-0"2'-0" FTG REINF FTG REINF 2 1 1' - 0"2'-0" MAXNOTE: ALL BENT BARS SAME SIZE AND SPACING AS HORIZONTAL STEEL CORNER DETAIL NOTE: ALL BENT BARS SAME SIZE AND SPACING AS HORIZONTAL STEEL INTERSECTION DETAIL NOTE: ALL BENT BARS SAME SIZE AND SPACING AS HORIZONTAL STEEL CORNER DETAIL NOTE: ALL BENT BARS SAME SIZE AND SPACING AS HORIZONTAL STEEL INTERSECTION DETAIL LAP - SEE SCHED TOP BAR TENSION LAP - SEE SCHEDTOP BAR TENSIONLAP - SEE SCHED TOP BAR TENSION LAP - SEE SCHEDTOP BAR TENSIONLAP - SEE SCHED TOP BAR TENSION LAP - SEE SCHEDTOP BAR TENSIONLAP - SEE SCHED TOP BAR TENSION LAP - SEE SCHED TOP BAR TENSION LAP - SEE SCHEDTOP BAR TENSIONSTD HOOK #5 CONT (2) #5 CONT , BOTT GRANULAR FILL CONC SLAB 1' - 0"3' - 0"BAR SIZE & NUMBER x 5'-0" TO MATCH FTG REINF SEE WALL FTG SCHED FOR REINF PVC SLEEVE AS REQ'D LAP LENGTH 1' - 4"4"T/STL -(SEE PLAN)8"1' - 4" 2'-0" 2 1 SEE SCHED6"MIN4"1' - 0"4' - 0"1' - 0"8" ELEV SEE SILL ANGLE - L6x6x1/2" (4) #5 HORIZ #6 @ 12" OC, EW, T&B HYDRAULIC SHAFT OPNG IF REQD 3" CLRRX WATERSTOP GRANULAR FILL CONC SLAB L5x3x1/4" (LLV) w/ 1/2"Øx4" HS @ 2'-0" OC T/SLAB +(SEE PLAN) T/ELEV SLAB +(SEE PLAN)VERIFY w/ ELEVATOR SUPPLIER1'-0"x#5 @ 12" OC, CENTER IN WALL 2'-0"2'-0"x#5 @ 12" OC 1" CLR8"5/16 4-12 SEE ARCH FOR ELEVATOR PIT WATERPROOFING ELEVATOR WALL ELEVATOR SLAB REINF TO MATCH PIT SLAB 1' - 6"1' - 6"1' - 0"SLABDEPTHCOORDCOORD ELEVATOR SLAB 1 1 SUMP PIT, COORD SIZE, DEPTH AND LOCATION w/ ELEVATOR SUPPLIER T/SLAB +(SEE PLAN) SECTION A-A SUMP PIT, COORD SIZE, DEPTH AND LOCATION w/ ELEVATOR SUPPLIER ELEVATOR WALL ELEVATOR SLAB ISOMETRIC OF SUMP PIT AAT/STL +(SEE PLAN) T/STL +(SEE PLAN) T/SLAB +(SEE PLAN) SLAB L5x3x1/4x2'-0" (LLH) w/ (2) 1/2"x4" HSA L3x3x3/8 (EACH FACE) WELD TO BEAM AND HSSTYPICAL RAIL SUPPORT HSS12x4x5/16 COORD LOCATION w/ MFR BEAM DECK EMBED PLATE 3/8"x4"x2'-0" w/ (2) 1/2"x3 1/2" HSA. WELD TO EDGE ANGLE DECK 1/4 L3x3x3/8 (4 SIDES OF COLUMN) DO NOT WELD ANGLES TO COLUMN) AT ELEVATOR PIT AT FLOOR AT ROOF 1/4 TYPICAL RAIL SUPPORT HSS12x3x5/16 COORD LOCATION w/ MFRVERIFY CLEARANCEw/ ELEVATOR MFRW8x24 HOIST BEAM EXTEND TO BEAM (BEYOND) 1/4 HSS RAIL SUPPORT ELEVATOR DIVIDER BEAM L3x3x1/4x0'-4" BS (TYP) 1/2" GAP FOR FIELD FIT ELEVATOR PIT W12x22 ELEVATOR DIVIDER BEAM HSS RAIL SUPPORT ELEVATOR DIVIDER BEAM HSS RAIL SUPPORT T/STL +(SEE PLAN) T/STL +(SEE PLAN) T/STL AELEVATOR PIT PLAN SECTION A SCALTE: NTS SEE 6/S403 FOR CONN SEE WALL SCHED AND 3/S403 FOR REINF EMBED PLATE 5/8"x12"x12" w/ (4) 3/4"Ø x 6"HEADED STUDS 1/4 1/4 1/4 T/STL +(SEE PLAN) DECK BEAM L3x3x3/8 (EA FACE OF COL) DO NOT WELD ANGLES TO COL1/4 HOIST BEAM8"8" #4 CONT TYP IN THICKENED EDGE SS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m Construction Manager: Civil Engineer: Owner: MIDTOWN EAST BLOCK 3 OFFICE 55 Monument Circle, Suite 450 Indianapolis, IN 46204 317-507-6067 F.A. WILHELM CONSTRUCTION COMPANY 3914 Prospect St. Indianapolis, IN 46203 317-359-5411 Civil & Environment Consultants, Inc. 560 E. Ohio Street Suite G Indianapolis, IN 46204 Structural Engineer: McComas Engineering 1717 East 116th Street Suite 200 Carmel, IN 46032 MEP Engineer: Freije 11800 Exit 5 Pkwy Suite 106 Fishers, IN 46037 PERMIT ISSUE 2017-04-24 571 Monon Blvd. Carmel, INKLS CRM 2017-02-27 S405 TYPICAL DETAILS MEI 17017MIDTOWN EAST BLOCK 3 OFFICESCALE:S405 3/4" = 1'-0" 1TYPICAL CORNER PIER DETAIL SCALE:S405 3/4" = 1'-0" 2TYPICAL PIER DETAIL SCALE:S405 3/4" = 1'-0" 3TYPICAL PIER ELEVATION SCALE:S405 3/4" = 1'-0" 4TYPICAL COLUMN BASE SECTION SCALE:S405 3/4" = 1'-0" 5TYP TOP OF FOOTING STEP SCALE:S405 3/4" = 1'-0" 6TYP REINFORCED WALL DETAILS SCALE:S405 3/4" = 1'-0" 7TYP TURNED DOWN SLAB SECTION SCALE:S405 3/4" = 1'-0" 8TYP SLEEVE DETAIL AT WALL FTG SCALE:S405 3/4" = 1'-0" 9ELEVATOR PIT DETAIL SCALE:S405 3/4" = 1'-0" 10TYP ELEVATOR SUMP SCALE:S405 3/4" = 1'-0" 11HSS ELEVATOR RAIL SECTION SCALE:S405 3/4" = 1'-0" 12ELEVATOR DIVIDER BEAM SECTION SCALE:S405 3/4" = 1'-0" 13SLAB @ GRADE # DESCRIPTION DATE 36/3 PATTERN ALL SUPPORTS NOTE: 1. ALL WELDS SHALL BE 5/8"Ø PUDDLE WELDS. 2. USE (1) #10 TEK SCREWS SIDELAP FASTENER PER SPAN 3. FASTEN PERIMETER AND EDGES OF OPENINGS @ 6" OC. 3' - 0" 36/4 PATTERN ALL SUPPORTS (TYP UNO) 36/5 PATTERN ALL SUPPORTS 36/7 PATTERN ALL SUPPORTS CONTINUOUS BEAM SIMPLE BEAM (MID COLUMN) COLUMN CENTERLINEBEAM 3/4" THICK CAP PLATE (TYP) 1/4" BRG STIFFENER (ONE EACH SIDE OF WEB) TYP d/23". 3/4"Ø BOLT (4 TOTAL) REF NOTE 5 HSS COLUMN 3/16 MIN 1/4TYP 3/8" SHEAR TAB HSS COLUMN BEAMBEAM 3/4"Ø BOLTS(TYP)1/2" MAX 2 1/2"4" MIN SIMPLE BEAM @ TOP OF COLUMN SIMPLE BEAM @ TOP OF COLUMN 5/8" CAP PLATE BEAM 3/4"Ø BOLTS (TYP) 1/4TYP 3/8" SHEAR TAB WIDE FLANGE COLUMN BEAM 2 1/2"1/2" MAX 4" MIN 5/8" CAP PLATE BEAM 3/4"Ø BOLTS (TYP) 1/4TYP 3/8" SHEAR TAB HSS COLUMN BEAM 2 1/2"1/2" MAX 4" MIN ANGLE OR BENT PL, CONT w/ 1/2"x6"STUDS @ 12" OC (MIN THICKNESS 3/8") ANGLE OR BENT PL, CONT (MIN THICKNESS 1/4") BEAM OR JOIST DECK CONC SLAB DECK JOIST BEAM OR JOIST GIRDER JOIST OR BEAM DECK PERIMETER ANGLE FOR CONCRETE SLAB (BEAM OR JOISTS) PERIMETER ANGLE FOR ROOF (ON JOIST) PERIMETER ANGLE FOR ROOF DECK (JOIST OR BEAM) 3/16 2-12 MAY BE SHOP WELDED 3/16 2 3/16 2-12 1/2" #3x3'-0" w/ 180DEG HOOKED ENDS @ 12" OC #5 CONT ON STUDS DECK JOIST BEAM OR JOIST GIRDER PERIMETER ANGLE FOR CONCRETE SLAB (ON JOIST) 3/16 2 1/2" ANGLE OR BENT PL, CONT w/ 1/2"x6"STUDS @ 12" OC (MIN THICKNESS 3/8") ANGLE OR BENT PL, CONT (MIN THICKNESS 1/4") #3x3'-0" w/ 180DEG HOOKED ENDS @ 12" OC #5 CONT ON STUDS SEE PLAN SEE PLAN SEE PLANSEE PLAN FRAMING MEMBERS BEAMS OR JOISTS PROVIDE L3x3x1/4 FOR EDGE OF DECKING SUPPORT FIELD WELD OR SHOP WELD TO OPENING FRAME (4 REQ'D) OPENING ANGLE SIZE FOR OPNG FRAME: HORIZ LEG = 3" VERT LEG = DEPTH OF SLAB THICKNESS = 3/8" MIN NOTES: 1. MECH CONTRACTOR SHALL PROVIDE FABRICATOR WITH OPENING SIZE AND LOCATIONS. 2. REFER TO ARCH DWGS FOR LOCATION OF OPENINGS. 3. PROVIDE THIS DETAIL AT ALL OPENINGS GREATER THAN 12" SQUARE. 4. PROVIDE THIS DETAIL FOR OPENINGS UP TO 3'-0" x 3'-0" SQUARE (MAX). 1/4 TYP WP ERECTION BOLT (TYP) COLUMN HSS BRACE COL BASE PLATE GUSSET PLATE WP ERECTION BOLT (TYP) HSS BRACEGUSSET PLATE T/STL +(SEE PLAN) BEAM TYP ROOF CURB DECK CHANNEL PROVIDE STIFFENER L2x2x1/4 EA SIDE OF JOIST TO BOTTOM CHORD PANEL POINT CENTERLINE OF JOIST OR BEAM EXTEND CHANNELS TO NEXT JOIST IF REQ'D, DO NOT CANTILEVER MORE THAN 1'-0" MECHANICAL UNIT MECHANICAL CURB MUST BE CAPABLE OF SPANNING TO SIDE CHANNELS 6'-0" CENTERLINE OF JOIST OR BEAM JOIST ONLY L3x3x1/4 FRAME AT OPNG JOIST PANEL POINT VARY w/ TYPE OF JST, SEE PLAN FOR SIZE (JOIST ONLY) SECTION A CHANNEL FRAME PLAN 1' - 11" MAX O P N G S IZ E OPNG SIZE L3x3x1/4 (TYP)C L T O C L O F F R A M IN G C O P E A S R E Q 'D @ C O R N E R S T O F IT O V E R J O IS T S T O P C H O R D O R B E A M F L A N G E OPNG CL CLDECKSPANC6x10.5 C6x10.5 FRAMING ANGLE FRAME DETAIL NOTES: 1. MECH CONTRACTOR SHALL PROVIDE FABRICATOR WITH SIZES AND LOCATIONS 2. REFER TO ARCH DRAWINGS FOR LOCATIONS OF OPENINGS. 3. PROVIDE THIS DETAIL AT ALL OPENINGS GREATER THAN 12" SQUARE, INCLUDING ROOF DRAINS. 4. PROVIDE CHANNEL FRAME FOR UNITS GREATER THAN 250lbs FOR OPEINGS.AAWHERE C6 CROSSES JST OR BM 1/4 TYP 1/4 TYP DECK BEAM SLIT PLATE AT BEAM WEB MIN PLATE 1/2"x4", OR AS SHOWN ON OTHER SECTIONS T/STL +(SEE PLAN) 3/4" EXTENSION IF IDENTIFIED IN SPECIFIC DETAILS (NOTE 2)A2 1/2"2 1/2" FOR "K" SERIES JST SEAT 5" FOR "LH" SERIES JOIST SEATBEAM T/STL +(SEE PLAN) SECTION A NOTES: 1. COPE BEAM TO GIRDER FLANGE. 2. TOP FLANGE AND PLATE MAY BE EXTENDED AS CANTILEVERE, SEE SPEC.S 3. PLATE MAY BE BOLTED TO GIRDER, SEE SPECS. OR AS SHOWN ON OTHER SECTIONS EXTENSION OR AS SHOWN ON OTHER SECTIONS ALT: 1/2" A325 BOLTS TO SUPPORTING BEAM OR GIRDER (SEE NOTE 3) 3/16 NS, FS OR AS SHOWN ON OTHER SECTIONS 3/16 2 TYP 1/4 2 0 0 ROOF DRAIN (SEE PLUMBING DRAWINGS FOR OPENING SIZE AND LOCATION) BEAM L3x3x1/4 SUPPORT FRAME BEAM 14 GA 24"x24" PANS (SEE MECH) OVERFLOW DRAIN (SEE PLUMBING DRAWINGS FOR OPENING SIZE AND LOCATION) DECK L? INTERIOR EXTENSION EXTENSION EXTERIOR EXTENSION INTERIOR EXTENSION EXTERIOR LINTEL PLAN REPRESENTATION LINTEL MARK LINTEL INDICATES LINTEL START END WALL WALL INTERIOR EXTERIOR CENTERLINE OF STEEL LINTEL LINTEL (WIDE FLANGE OR HSS)ALINTEL SECTION A T/STL B/STL T/PLATE B/PLATE SEE PLAN FOR ELEVATION CALLED OUT WIDTH TOTAL TOTAL WIDTH THICKNESSTHICKNESSTOP PLATE BOTTOM PLATE DECK JOIST BEAM 1/8 2 JOIST 1/4 3 1/4 3 STIFFENED JOIST SEAT ANGLE - SEE SCHEDULE COLUMN JOIST DECK BEAM 3/4" CAP PLATE JOIST STABILIZER PLATE COLUMN COLUMN ANGLE ELEVATION @ TYP UNSTIFFENED SEAT UNSTIFFENED JOIST SEAT ANGLE BEARING CAPACITY MIN COL WIDTH 6" WIDTH MIN COL W OR HSS COL ANGLE WIDTH MIN COL W OR HSS COL 3/8" STIFFENER PLATE COLUMN ELEVATION @ TYP STIFFENED SEAT SEAT ANGLE SEAT ANGLE LENGTH ASD CAPACITY L5x3 1/2x3/8 (LLV) L5x3 1/2x1/2 (LLV) 4" 1.9k 4.1k 8" 5" 2.4k 5.1k 8" 6" 2.9k 6.2k 9" 7" 3.4k 7.2k 10" 8" 3.9k 8.2k 12" 9" 4.4k 9.3k 12" 10" 4.9k 10.3k STIFFENED JOIST SEAT ANGLE BEARING CAPACITY MIN COL WIDTH 6" SEAT ANGLE SEAT ANGLE LENGTH ASD CAPACITY L6x4x1/2 (LLV) L6x4x1/2 (LLV) 4" 26.0k 44.2k 8" 5" 8" 6" 9" 7" 10" 8" 12" 9" 12" 10" 26.0k 44.2k 26.0k 44.2k 26.0k 44.2k 26.0k 44.2k 26.0k 44.2k 26.0k 44.2k 5/16 3/4" RET @ TOP 5/16TOP & SIDES 5/16 SS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m Construction Manager: Civil Engineer: Owner: MIDTOWN EAST BLOCK 3 OFFICE 55 Monument Circle, Suite 450 Indianapolis, IN 46204 317-507-6067 F.A. WILHELM CONSTRUCTION COMPANY 3914 Prospect St. Indianapolis, IN 46203 317-359-5411 Civil & Environment Consultants, Inc. 560 E. Ohio Street Suite G Indianapolis, IN 46204 Structural Engineer: McComas Engineering 1717 East 116th Street Suite 200 Carmel, IN 46032 MEP Engineer: Freije 11800 Exit 5 Pkwy Suite 106 Fishers, IN 46037 PERMIT ISSUE 2017-04-24 571 Monon Blvd. Carmel, INKLS CRM 2017-02-27 S406 TYPICAL DETAILS MEI 17017MIDTOWN EAST BLOCK 3 OFFICESCALE:S406 3/4" = 1'-0" 2ROOF DECK FASTENER PATTERN SCALE:S406 3/4" = 1'-0" 3TYP STL BEAM CONNECTIONS SCALE:S406 3/4" = 1'-0" 4TYP PERIMETER ANGLE CONN SCALE:S406 3/4" = 1'-0" 5FLR SLAB FRAMED OPNG DETAIL SCALE:S406 3/4" = 1'-0" 6BRACED FRAMED DETAIL SCALE:S406 3/4" = 1'-0" 7BRACED FRAMED DETAIL SCALE:S406 3/4" = 1'-0" 8TYPICAL ROOF OPENING FRAME SCALE:S406 3/4" = 1'-0" 9TYP SEAT BRG FOR BEAMS SCALE:S406 3/4" = 1'-0" 10SECTION @ ROOF DRAIN SCALE:S406 1 1/2" = 1'-0" 11STEEL LINTEL KEY PLAN SCALE:S406 3/4" = 1'-0" 12JSTS TO BEAM CONN DETAIL SCALE:S406 3/4" = 1'-0" 13TYP JOIST SEAT AT COLUMN SCALE:S406 3/4" = 1'-0" 14JOIST TO COLUMN DETAIL SCALE:S406 3/4" = 1'-0" 15JOIST SEAT BRG CAPACITY # DESCRIPTION DATE D D.1 T/F (SEE PLAN) T/LEDGE (SEE PLAN) T/SLAB (SEE PLAN) CW14 FUTURE SLAB E T/SLAB (SEE PLAN) T/SLAB (SEE PLAN) T/F (SEE PLAN) CW101/2" EXP JOINT MATERIAL SOG04P T/SLAB (SEE PLAN) T/F (SEE PLAN) SOG04P 1/2" EXP JOINT MATERIAL 1 1' - 10" 7"7"8" T/LEDGE (SEE PLAN) T/F (SEE PLAN) T/LEDGE (SEE PLAN) CW14 FUTURE SLAB 1 7"7" NOTE: FOOTING REINF IS CONTINUOUS THROUGH COLUMN FOOTING NOTE: WALL HORIZONTALS ARE CONTINUOUS THROUGH PIER ELEMENTS 1' - 10" T/LEDGE (SEE PLAN) T/F (SEE PLAN) T/SLAB (SEE PLAN) 1 7"7"8" 1' - 10"5' - 3 1/8" T/LEDGE (SEE PLAN) T/F (SEE PLAN) T/SLAB (SEE PLAN) T/SLAB (SEE PLAN) CW14 CW8 SOG04P 1/2" EXP JOINT MATERIAL6"8"1' - 6"(2) #4 CONT T/SLAB SEE PLAN T/SLAB SEE PLAN SEE ARCH FOR NUMBER OF RISERSEQUAL RISERS#3 NOSING BAR (TYP) WWF T/SLAB SEE PLAN 8"CONC WALL (CW) 1'-6"1'-6"x#4 @ 12" OC #4 x 1'-4" @ 12" OC SS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m Construction Manager: Civil Engineer: Owner: MIDTOWN EAST BLOCK 3 OFFICE 55 Monument Circle, Suite 450 Indianapolis, IN 46204 317-507-6067 F.A. WILHELM CONSTRUCTION COMPANY 3914 Prospect St. Indianapolis, IN 46203 317-359-5411 Civil & Environment Consultants, Inc. 560 E. Ohio Street Suite G Indianapolis, IN 46204 Structural Engineer: McComas Engineering 1717 East 116th Street Suite 200 Carmel, IN 46032 MEP Engineer: Freije 11800 Exit 5 Pkwy Suite 106 Fishers, IN 46037 PERMIT ISSUE 2017-04-24 571 Monon Blvd. Carmel, INKLS CRM 2017-02-27 S407 SECTIONS & DETAILS MEI 17017MIDTOWN EAST BLOCK 3 OFFICESCALE:S407 3/4" = 1'-0" 1SECTION SCALE:S407 3/4" = 1'-0" 2SECTION SCALE:S407 3/4" = 1'-0" 3SECTION SCALE:S407 3/4" = 1'-0" 4SECTION SCALE:S407 3/4" = 1'-0" 5SECTION SCALE:S407 3/4" = 1'-0" 6SECTION SCALE:S407 3/4" = 1'-0" 7SECTION 4 # DESCRIPTION DATE 4 Addendum 04 2017-04-17 8 BEAM BEAM T/STL +(SEE PLAN) SEE PLAN EOS BENT PLATE - SEE 4/S406 SLAB CFS FRAMED WALL VENEER - SEE ARCH L7X4X1/2 L3x2x3/16 KICKERS W/ 1/4x4x4 TABS @ 4'-0" OC TYP (2) AT BRICK PILASTER ELEMENTS 8 BEAM T/STL +(SEE PLAN) BENT PLATE - SEE 4/S406 SLAB CFS FRAMED WALL VENEER - SEE ARCH SEE PLAN EOS L7X4X1/2 L3x2x3/16 KICKERS W/ 1/4x4x4 TABS @ 4'-0" OC TYP (2) AT BRICK PILASTER ELEMENTS BEAM 8 BEAM BEAM T/STL +(SEE PLAN) BENT PLATE - SEE 4/S406 SLAB CFS FRAMED WALL VENEER - SEE ARCH SEE PLAN EOS L7X4X1/2 8 BEAM T/STL +(SEE PLAN) SLAB CFS FRAMED WALL VENEER - SEE ARCH SEE PLAN EOS L7X4X1/2 BENT PLATE - SEE 4/S406 L3x2x3/16 KICKERS W/ 1/4x4x4 TABS @ 4'-0" OC TYP (2) AT BRICK PILASTER ELEMENTS PROVIDE (5) BOLT DBLE CLIP AT GRID C AS TORSIONAL RESTRAINT FOR EDGE GIRDER. 8 T/SLAB +(SEE PLAN) SEE PLAN EOS BENT PLATE - SEE 4/S406 CFS FRAMED WALL VENEER - SEE ARCH BEAM L7X4X1/2 L3x2x3/16 KICKERS W/ 1/4x4x4 TABS @ 4'-0" OC TYP (2) AT BRICK PILASTER ELEMENTS SEE PLAN EOS D T/SLAB +(SEE PLAN) SEE 4/S406 BENT PLATE - CANTILEVERED CFS KNEE WALL VENEER - SEE ARCH BEAM SEE PLAN EOS GALV LOOSE LINTEL, SEE SCHEDULE 5/16 2-12 5/16 2-12 TYP L7X4X1/2 L3x2x3/16 KICKERS W/ 1/4x4x4 TABS @ 4'-0" OC TYP (2) AT BRICK PILASTER ELEMENTS D SEE PLAN EOS T/SLAB +(SEE PLAN) BENT PLATE - CFS FRAMED WALL VENEER - SEE ARCH BEAM SEE 4/S406 SLAB GALV LOOSE LINTEL, SEE SCHEDULE VENEER PILASTER- SEE ARCH L7X4X1/2 5/16 2-12 5/16 2-12 TYP L3x2x3/16 KICKERS W/ 1/4x4x4 TABS @ 4'-0" OC TYP (2) AT BRICK PILASTER ELEMENTS D T/SLAB +(SEE PLAN) BENT PLATE - CFS FRAMED WALL VENEER - SEE ARCH BEAM SLAB SEE PLAN EOS SEE 4/S406 L7X4X1/2 VENEER - SEE ARCH 560PLF BRICK L3x2x3/16 KICKERS W/ 1/4x4x4 TABS @ 4'-0" OC TYP (2) AT BRICK PILASTER ELEMENTS D D.1 SEE PLAN EOS2' - 6" T/SLAB +(SEE PLAN) SEE 4/S406 BENT PLATE - BEAM JOIST SLAB CURTAIN WALL ATTACHMENT BY OTHERS E L2x2x3/16 L2x2x3/16 L3x3x1/4 L4x4x3/16 L6x6x5/16 CONT,COORDINATE ANGLE POSITION, ELEVATION, AND EXTENTS w/ ARCHITECT & CURTAIN WALL DETAILS CEILING FRAMING BY OTHERS WALL FRAMING BY OTHERS BEARING INTO L6x6 LOCATE SUPPORT FRAMES AT JOIST BOTTOM CHORD PANEL POINTS NOT MORE THAN 4'-0" OC 3/16 3/16TYP 3/16 3/16 3/16TYP CFS DESIGNER NOTE CANTILEVERED KNEE WALL CONDITIONS THROUGHOUT PROJECT. COORDINATE WITH CURTAINWALL WIND REACTIONS WHEN DESIGNING ATTACHMENT TO SLAB EDGE, COORDINATE TOP TRACK GAGE WITH CURTAINWALL REQUIREMENTS. 1 BEAM JOIST SLAB BENT PLATE - SEE 4/S406 T/SLAB +(SEE PLAN) DESIGN JOIST EXTENTIONS FOR 150 PLF WALL LOAD SEE PLAN EOS L6X6X5/16 L4x4x1/4 @ 5'-0" OC MATCHING JOIST LAYOUT AND AT COLUMN L2x2x3/16 EA LOCATION 3/16 3/16 3/16 SEE 9/S408 FOR SPECIAL CFS FRAMING NOTES COORDINATE EXTENTS w/ ARCHITECT 1 SEE PLAN EOS SLAB T/SLAB +(SEE PLAN) VENEER - SEE ARCH BEAM JOIST CFS FRAMED WALL CFS FRAMED WALL L7X4X1/2 DESIGN JOIST EXTENSIONS FOR 560PLF WALL LOAD 4 SEE PLAN EOS BEAM JOIST BEAM T/SLAB +(SEE PLAN) T/SLAB +(SEE PLAN) SLAB SLAB CFS FRAMED WALL L6x4x5/16 1/4 2-12 D BENT PLATE - SEE 4/S406 SEE PLAN CURTAIN WALL ATTACHMENT BY OTHERS A L3x3x3/16 L2x2x3/16 L3x3x3/16 L2x2x3/16 L2x2x3/16 L3x3x3/16 L4x4x1/4 CONT 3/16 TYP 3/16 3/16 TYP 3/16 3/16TYP FRAMES AT 4'-0" OC MAX, LOCATE AT JOIST BOTTOM CHORD PANEL POINTS T/CONC +130' - 0" COORDINATE B/STL ELEV AND OFFSET FROM GRID WITH ARCHITECTURAL A 1/4 1/4 TYP 1/4 1/2" END PLATE w/ (4) 3/4" BOLTS AT COLUMNS MC18X42.7 L6X3-1/2X3/8 1 1/2"T/STL +156' - 1 1/2" SEE ADJACENT SECTIONS FOR OTHER INFORMATION 1/4 1/4 L3x3x1/4 KICKERS TO T/ CHANNEL @ 6'-0" OC 1 3/16TOP & SIDES CLIP ANGLE TO FAR CHANNEL BEYOND COLUMN w/ (2) 3/4" BOLTS ON WIDE SPREAD L6X3-1/2X3/8 MC18X42.7 1/2"x10" END PLATE ON HSS w/ (4) 3/4" BOLTS HSS 6X6x1/4 HANGER AND CANTILEVER ARM w/ 1/2" CAP PLATE AND (4) 3/4" BOLT TO BEAM. CENTER ON ROOF BEAM L4x4x1/4 TO BEAM 1/4 0 0 1' - 0"SEE ADJACENT SECTIONS FOR OTHER INFORMATION SS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m Construction Manager: Civil Engineer: Owner: MIDTOWN EAST BLOCK 3 OFFICE 55 Monument Circle, Suite 450 Indianapolis, IN 46204 317-507-6067 F.A. WILHELM CONSTRUCTION COMPANY 3914 Prospect St. Indianapolis, IN 46203 317-359-5411 Civil & Environment Consultants, Inc. 560 E. Ohio Street Suite G Indianapolis, IN 46204 Structural Engineer: McComas Engineering 1717 East 116th Street Suite 200 Carmel, IN 46032 MEP Engineer: Freije 11800 Exit 5 Pkwy Suite 106 Fishers, IN 46037 PERMIT ISSUE 2017-04-24 571 Monon Blvd. Carmel, INKLS CRM 2017-02-27 S408 SECTIONS & DETAILS MEI 17017MIDTOWN EAST BLOCK 3 OFFICESCALE:S408 3/4" = 1'-0" 1SECTION SCALE:S408 3/4" = 1'-0" 2SECTION SCALE:S408 3/4" = 1'-0" 3SECTION SCALE:S408 3/4" = 1'-0" 4SECTION SCALE:S408 3/4" = 1'-0" 5SECTION SCALE:S408 3/4" = 1'-0" 6SECTION @ WINDOW SCALE:S408 3/4" = 1'-0" 7SECTION SCALE:S408 3/4" = 1'-0" 8SECTION SCALE:S408 3/4" = 1'-0" 9SECTION SCALE:S408 3/4" = 1'-0" 10SECTION SCALE:S408 3/4" = 1'-0" 11SECTION SCALE:S408 3/4" = 1'-0" 12SECTION SCALE:S408 3/4" = 1'-0" 13SECTION 2 2 SCALE:S408 3/4" = 1'-0" 14SECTION 2 SCALE:S408 3/4" = 1'-0" 15SECTION 2 SCALE:S408 3/4" = 1'-0" 16SECTION # DESCRIPTION DATE 2 Addendum 02 2017-04-03 A EOS 6 3/4" T/SLAB +(SEE PLAN) T/SLAB +(SEE PLAN) 3/16 2 3/16 2 PL 1/2 w/ (2) 3/4" BOLTS TO BEAM FLANGE L4x4x3/8 SEAT CLIPS w/ (2) 3/4" BOLTS 3/16 3/16 3/4" RET @ TOP CLIP ANGLES OR SINGLE TABS AT FABRICATORS DISCRETIONL6x4x5/16 A T/SLAB +(SEE PLAN) SEE PLAN EOS SLAB CFS FRAMED WALL BEAM CFS FRAMED WALL VENEER - SEE ARCH BENT PLATE - SEE 4/S406 L4x4x3/8 HANGER STUB w/ 3/4" BOLT AND 1/8"x3x3 FABRIKA THERMAL BREAK PAD BETWEEN WT AND HANGER. 3/16 TYP 1/4" GALV STEEL PLATE WT8X25 C5X6.7 3/16 3/16 3/16 2-12 TYP SEE ARCH FOR DIMENSIONS, ELEVATIONS, 1/4" PLATE EXTENTS, GUTTER CONSTRUCTION AND ATTACHMENTS, ALL SEALANT CONDITIONS. ALL WELDS TO GALV MATERIAL ARE TO BE TOUCHED UP WITH ZINC RICH COLD GALVANIZING PAINT. INTERMEDIATE WTs ARE SUPPORTED ON CHANNELS, CHANNELS ARE CONTINUOUS BETWEEN CANTILEVERD WTs GALV C5X6.7 L7X4X1/2 BACK OF INTERMEDIATE WTs AT BACK OF PLATE A T/SLAB +(SEE PLAN) SEE PLAN EOS SLAB BEAM VENEER - SEE ARCH CFS FRAMED WALL L7X4X1/2 BENT PLATE - SEE 4/S406 L3x2x3/16 KICKERS W/ 1/4x4x4 TABS @ 4'-0" OC TYP (2) AT BRICK PILASTER ELEMENTS B T/SLAB +(SEE PLAN) SLAB BEAM 1/4 2-12 L6x4x5/16 x CONT (LLV) STAIR CONNECTION TO BEAM BY STAIR SUPPLIER STAIR STRINGER - SEE ARCH 2' - 10" FUTURE CHASE, INITIAL SLAB CONTINUOUS, TYP ALL FLOORS 2 SEE PLAN EOS L6x6x3/8 x CONT SEE 4/S406 1/4 2-12 T/SLAB +(SEE PLAN) SLAB BEAM JOIST BY STAIR SUPPLIER 3/8" CONNECTION PLATE - FULL HEIGHT STIFFENER PLATE STAIR HANGER ROD - BY STAIR SUPPLIER STAIR LANDING - BY STAIR SUPPLIER L3x3x1/4 BRACE 3/8" CONN PLATE 1/4 EA END 1/4 3 1/4 3 C T/SLAB +(SEE PLAN) SEE PLAN EOS 1/4 2-12 SLAB BEAM CFS SHAFT WALL - SEE ARCH 3/8"x6"x EOS x CONT BENT PLATE SEE 4/S406 EOD - SEE PLAN #4 CONT CENTERLINE OF BEAM #3 x @ 12" OC2'-0" T/SLAB +(SEE PLAN) BEAM SILL ANGLE L6x6x1/2 (COORD w/ ELEVATOR MFR) 3/8"x6" x EOS x CONT BENT PLATE w/ 1/2"Ø x 6" HS @ 1'-0" OC 3 L6x4x5/16 x CONT 3/16 TYP T/SLAB +(SEE PLAN) EOS - SEE PLAN T/STL +(SEE PLAN) 1/4 3 1/4 3 BEAM JOIST SHAFT WALL NOT SHOWN FOR CLARITY SEE 4/S406 JOIST FABRICATOR NOTE UNBRACED TOP CHORD CONDITION AT CHASE. L6x4x5/16 PERIMETER ANGLES L5x3x1/4 ALIGNED w/ JOIST LAYOUT A SEE 15/S408 FOR COLUMN STUB, CHANNEL, AND BRICK LEDGER L4x4x1/4 @ 6'-0" OC TO BEAM WEB SEE 3/S409 FOR BALANCE OF INFORMATION SS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m Construction Manager: Civil Engineer: Owner: MIDTOWN EAST BLOCK 3 OFFICE 55 Monument Circle, Suite 450 Indianapolis, IN 46204 317-507-6067 F.A. WILHELM CONSTRUCTION COMPANY 3914 Prospect St. Indianapolis, IN 46203 317-359-5411 Civil & Environment Consultants, Inc. 560 E. Ohio Street Suite G Indianapolis, IN 46204 Structural Engineer: McComas Engineering 1717 East 116th Street Suite 200 Carmel, IN 46032 MEP Engineer: Freije 11800 Exit 5 Pkwy Suite 106 Fishers, IN 46037 PERMIT ISSUE 2017-04-24 571 Monon Blvd. Carmel, INKLS CRM 2017-02-27 S409 SECTIONS & DETAILS MEI 17017MIDTOWN EAST BLOCK 3 OFFICESCALE:S409 3/4" = 1'-0" 1SECTION SCALE:S409 3/4" = 1'-0" 2SECTION @ PIER & CANOPY SCALE:S409 3/4" = 1'-0" 3SECTION SCALE:S409 3/4" = 1'-0" 4SECTION @ STAIR SCALE:S409 3/4" = 1'-0" 5SECTION SCALE:S409 3/4" = 1'-0" 6SECTION SCALE:S409 3/4" = 1'-0" 7EDGE OF SLAB AT ELEVATOR SCALE:S409 3/4" = 1'-0" 8SECTION2 2 2 SCALE:S409 3/4" = 1'-0" 9SECTION2 # DESCRIPTION DATE 2 Addendum 02 2017-04-03 1 T/STL +(SEE PLAN) JOIST BEAM DECK VERTICAL SLIDE CLIP TO BENT PLATE BENT PLATE w/ 4" VERT LEG, PROVIDE 1/2" ALIGNMENT GAP. T/PARAPET +(SEE ARCH) SEE 2/S410 FOR BALANCE OF INFORMATION EOD - SEE PLAN 1 BEAM JOIST DECK T/STL +(SEE PLAN) VERTICAL SLIDE CLIP TO BENT PLATE BENT PLATE w/ 4" VERT LEG, PROVIDE 1/2" ALIGNMENT GAP, VERIFY CFS STUD DEPTH BEFORE FABRICATION (3 5/8" STUD FRAMING INDICATED ON ARCH). L4x4x1/4 CONT BRICK LEDGE, FASTENING TO CFS FRAMING BY OTHERS FOR 40 PLF DL. SEE ARCH FOR ELEVATION C6x10.5 CONT SEE JOIST REINF DETAIL IF CHANNEL DOES NOT BEAR DIRECTLY OVER TOP CHORD PANEL POINT. 3/16 2 3/16 2 CFS FRAMING BY OTHERS, SEE ARCH FOR SHEATHING CFS FRAMING BY OTHERS, NOT THIS WALL CARRIES THE PARAPET AND CANTILEVER ABOVE. T/PARAPET +(SEE ARCH) SEE PLAN EOD 1 T/STL +(SEE PLAN) BEAM DECK L4x4x1/4 CONT BRICK LEDGE, FASTENING TO CFS FRAMING BY OTHERS FOR 40 PLF DL. SEE ARCH FOR ELEVATION BUILT-UP ANGLE EXTENSION FOR EDGE ANGLE SUPPORT SEE 2/S410 FOR BALANCE OF INFORMATION A T/STL +(SEE ARCH) BEAM BEAM C4x7.2xCONT C6x10.5 @ 4'-0" OC3/16 2 3/16 2 SEE 2/S410 FOR BALANCE OF INFORMATION L4x4x1/4 CONT BRICK LEDGE, FASTENING TO CFS FRAMING BY OTHERS FOR 40 PLF DL. SEE ARCH FOR ELEVATION EOD - SEE PLAN 8 C6x10.5xCONT L4x4x1/4 CONT SEE ARCH FOR GEOMETRY OF PARAPET SEE PLAN EOD L4x4x1/4 CONT BRICK LEDGE, FASTENING TO CFS FRAMING BY OTHERS FOR 40 PLF DL. SEE ARCH FOR ELEVATION 8 C6x10.5xCONT L4x4x1/4 CONT L4x4x1/4 CONT BRICK LEDGE, FASTENING TO CFS FRAMING BY OTHERS FOR 40 PLF DL. SEE ARCH FOR ELEVATION 8 C6x10.5xCONT L4x4x1/4 CONT L4x4x1/4 CONT BRICK LEDGE, FASTENING TO CFS FRAMING BY OTHERS FOR 40 PLF DL. SEE ARCH FOR ELEVATION SEE PLAN EOD D.1 SEE 2/S410 FOR BALANCE OF INFORMATIONSEE 5/S410 NOTE: SECTION IS APPROXIMATE, COMPLETE ARCHITECTURAL IS NOT AVAILABLE AT THIS CONDITION FOR STEEL PACKAGE. E EOD - SEE PLAN D D.1 L4x4x1/4 CONT BRICK LEDGE, FASTENING TO CFS FRAMING BY OTHERS FOR 40 PLF DL. SEE ARCH FOR ELEVATION SEE 5/S410 FOR BALANCE OF INFORMATION SEE PLAN EOD E SS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m Construction Manager: Civil Engineer: Owner: MIDTOWN EAST BLOCK 3 OFFICE 55 Monument Circle, Suite 450 Indianapolis, IN 46204 317-507-6067 F.A. WILHELM CONSTRUCTION COMPANY 3914 Prospect St. Indianapolis, IN 46203 317-359-5411 Civil & Environment Consultants, Inc. 560 E. Ohio Street Suite G Indianapolis, IN 46204 Structural Engineer: McComas Engineering 1717 East 116th Street Suite 200 Carmel, IN 46032 MEP Engineer: Freije 11800 Exit 5 Pkwy Suite 106 Fishers, IN 46037 PERMIT ISSUE 2017-04-24 571 Monon Blvd. Carmel, INKLS CRM 2017-02-27 S410 SECTIONS & DETAILS MEI 17017MIDTOWN EAST BLOCK 3 OFFICESCALE:S410 3/4" = 1'-0" 1SECTION SCALE:S410 3/4" = 1'-0" 2SECTION SCALE:S410 3/4" = 1'-0" 3SECTION SCALE:S410 3/4" = 1'-0" 5SECTION SCALE:S410 3/4" = 1'-0" 6SECTION SCALE:S410 3/4" = 1'-0" 7SECTION SCALE:S410 3/4" = 1'-0" 8SECTION SCALE:S410 3/4" = 1'-0" 9SECTION SCALE:S410 3/4" = 1'-0" 4SECTION 4 4 4 4 4 # DESCRIPTION DATE 4 Addendum 04 2017-04-17 C 3/8" BENT PLATE L4x4x1/4 CONT (SLOPED) 1/4TYP 1' - 0" 1' - 2 1/2" 3 1/2" 6 3/8" BENT PLATE L3x3x1/4 CONT L4x4x3/8" SEAT CLIP 1/4 1/4 6' - 3 3/4" 5' - 9 3/4" NOTE: CORNERS MAY BE MITERED OR BUTTED WITH 1/4" END PLATE 3 1/2" SS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m Construction Manager: Civil Engineer: Owner: MIDTOWN EAST BLOCK 3 OFFICE 55 Monument Circle, Suite 450 Indianapolis, IN 46204 317-507-6067 F.A. WILHELM CONSTRUCTION COMPANY 3914 Prospect St. Indianapolis, IN 46203 317-359-5411 Civil & Environment Consultants, Inc. 560 E. Ohio Street Suite G Indianapolis, IN 46204 Structural Engineer: McComas Engineering 1717 East 116th Street Suite 200 Carmel, IN 46032 MEP Engineer: Freije 11800 Exit 5 Pkwy Suite 106 Fishers, IN 46037 PERMIT ISSUE 2017-04-24 571 Monon Blvd. Carmel, INKLS CRM 2017-02-27 S411 SECTIONS & DETAILS MEI 17017MIDTOWN EAST BLOCK 3 OFFICESCALE:S411 3/4" = 1'-0" 1SECTION SCALE:S411 3/4" = 1'-0" 2SECTION 2 2 # DESCRIPTION DATE 2 Addendum 02 2017-04-03 WP 1 5/8" MAXERECTION BOLT (OPTIONAL) 3/8 3/8 TYP 1/4 1/4 3/4" GUSSET PLATE - GRADE 50 (CENTERED ON BEAM) HSS BRACE SLOTTED TO ACCOMODATE 3/4" PLATE BEAM 3/8" STIFFENER PLATE EACH FACE 1/2"x5" STIFFENER PLATE EACH FACE 5/16 5/16TYP C WP 5/16 5/16 TYP 3/4" GUSSET PLATE - GRADE 50 (CENTERED ON BEAM) HSS BRACE SLOTTED TO ACCOMODATE 3/4" PLATE 1/4 1/4TYP 3/8 3/8TYP 1/2"x5" STIFFENER PLATE EACH FACE ERECTION BOLT (OPTIONAL) COLUMN BEAM C WP 1 1/2" MAX3/4" GUSSET PLATE - GRADE 50 (CENTERED ON BEAM) HSS BRACE SLOTTED TO ACCOMODATE 3/4" PLATE ERECTION BOLT (OPTIONAL) 5/16 5/16 3/8 3/8 TYP 3/8" STIFFENER PLATE - EACH FACE BEAM 1/2"x6" STIFFENER PLATE - EACH FACE 1/4 1/4 B WP 1 1/2" MAX5/16 5/16 COLUMN 3/8 3/8 TYP BEAM ERECTION BOLT (OPTIONAL) 3/8" STIFFENER PLATE - EACH FACE SLAB BEAM HSS BRACE SLOTTED TO ACCOMMODATE 3/4" PLATE 3/4" GUSSET PLATE - GRADE 50 (CENTERED ON BEAM) C WP 3/8 13 3/4" GUSSET PLATE - GRADE 50 (CENTERED ON COLUMN) HSS BRACE SLOTTED TO ACCOMODATE 3/4" PLATE ERECTION BOLT (OPTIONAL) 1/2"x5" STIFFENER PLATE EACH FACE 1/4 1/4 3/4 3/4 PIER (P) SHEAR LUG BLOCKOUT SHEAR LUG 3"x5"x1'-2" 7/16 w/ (6) 1 1/2"Ø ANCHOR RODSBASE PLATE 2 1/2"x2'-2"x2'-10"2" NON-SHRINK GROUTT/P (SEE PLAN) 3/8 COLUMN NOTE: COLUMN ORIENTATION VARIES @ SIM C 3/8 13 3/4" GUSSET PLATE - GRADE 50 (CENTERED ON COLUMN) HSS BRACE SLOTTED TO ACCOMODATE 3/4" PLATE ERECTION BOLT (OPTIONAL) 1/2"x5" STIFFENER PLATE EACH FACE 1/4 1/4 3/4 3/4 PIER (P) SHEAR LUG BLOCKOUT SHEAR LUG 3"x5"x1'-2" 7/16 T/P (SEE PLAN) 3/8 COLUMN NOTE: COLUMN ORIENTATION VARIES @ SIM WP 2" NON-SHRINK GROUTw/ (6) 1 1/2"Ø ANCHOR RODSBASE PLATE 2 1/2"x2'-2"x2'-10"D.1 E 1/4" GALV STEEL PLATE 3/16 2-12 TYP SEE ARCH FOR DIMENSIONS, ELEVATIONS, 1/4" PLATE EXTENTS, GUTTER CONSTRUCTION AND ATTACHMENTS, ALL SEALANT CONDITIONS. ALL WELDS TO GALV MATERIAL ARE TO BE TOUCHED UP WITH ZINC RICH COLD GALVANIZING PAINT. GALVWT6X25 W12X30 W12X30 W12X30 3/16 3/16 L3x3x3/8 SEAT CLIP TAPERED TO SLOPE w/ (2) 3/4 GALV BOLTS1/4 1/4 GALV GALV7/16 7/16 TYP 1 1/2" PL w/ (8) 1" BOLTS 1/4" FABRIKA THERMAL ISOLATION PAD 3/8" WEB DOUBLER BOTH SIDES 5/16 GALV 5/16 5/16 TYP 3/4" FITTED STIFFENERS BOTH SIDES SS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m Construction Manager: Civil Engineer: Owner: MIDTOWN EAST BLOCK 3 OFFICE 55 Monument Circle, Suite 450 Indianapolis, IN 46204 317-507-6067 F.A. WILHELM CONSTRUCTION COMPANY 3914 Prospect St. Indianapolis, IN 46203 317-359-5411 Civil & Environment Consultants, Inc. 560 E. Ohio Street Suite G Indianapolis, IN 46204 Structural Engineer: McComas Engineering 1717 East 116th Street Suite 200 Carmel, IN 46032 MEP Engineer: Freije 11800 Exit 5 Pkwy Suite 106 Fishers, IN 46037 PERMIT ISSUE 2017-04-24 571 Monon Blvd. Carmel, INKLS CRM 2017-02-27 S412 SECTIONS & DETAILS MEI 17017MIDTOWN EAST BLOCK 3 OFFICESCALE:S412 3/4" = 1'-0" 1BRACING DETAIL SCALE:S412 3/4" = 1'-0" 2BRACING DETAIL SCALE:S412 3/4" = 1'-0" 3BRACING DETAIL SCALE:S412 3/4" = 1'-0" 4BRACING DETAIL SCALE:S412 3/4" = 1'-0" 5BRACING DETAIL SCALE:S412 3/4" = 1'-0" 6BRACING DETAIL SCALE:S412 3/4" = 1'-0" 7SECTION @ CANOPY 1 # DESCRIPTION DATE 1 Addendum 01 2017-03-13 BC W21X55 W24X55 W21X55 W21X55W12X53W12X96 W12X96W12X53HSS12X12X3/8HSS12X12X3/8HSS12X12X1/4 HSS12X12X1/4 S412 2 HSS8X8X3/8 HSS8X8X3/8HSS8X8X5/16 H S S 8 X 8 X 5/1 6 HSS6 X6 X1 /4 HSS6X6X1/4HSS6X6X1/2 H S S 6 X 6 X 1/2 ±167k± 1 6 7 k±137k± 1 3 7k±104k± 1 0 4k±48k± 4 8 k S403 1 SPLICE S403 1 SPLICE S403 4 SPLICE S403 4 SPLICE T/P +99' - 0" T/F +92' - 0" T/STL +115' - 1" T/STL +129' - 1" T/STL +143' - 1" T/STL +159' - 4" T/STL +161' - 10" T/STL +170' - 0" 25' - 0" TYP S412 1 TYP S412 5 TYP BC W16X31 W21X62 W21X62 W21X62W12X40 W12X40W12X72W12X72HSS6X6X3/8H S S8X 8X3 /8H S S 8X 8X1 /2 HSS10X10X3/8±4 2 k±9 8 k ±1 4 0 k ±1 6 8 k T/F +94' - 0" T/P +99' - 0" T/STL +115' - 1" T/STL +129' - 1" T/STL +143' - 1" T/STL +158' - 7" 25' - 0" S403 1 SPLICE S403 1 SPLICE S412 3 TYP S412 4 S412 6 2 3 HSS12X12X1/4 HSS12X12X1/4 W21X44 W24X55 W24X55 W24X62W12X53HSS12X12X3/8HSS12X12X3/8W12X53W12X96W12X96HSS10X10X1/2 HSS10X10X1/2 HSS10X10X1/2 HSS10X10X1/2 HSS10X10X1/4 HSS10X10X1/4 HSS8X8X1/4 HSS8X8X1/4 ±227k±227k±189k±189k±137k±137k±70k±70k30' - 0" T/STL +170' - 0" T/STL +161' - 10" T/STL +159' - 4" T/STL +143' - 6" T/STL +129' - 6" T/STL +115' - 6" T/P +99' - 0" T/F +92' - 0" S403 1 SPLICE S403 1 SPLICE S403 4 S403 4 SPLICESPLICE S412 1 TYP S412 2 SIM TYP S412 5 SIM TYP SS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c REVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m Construction Manager: Civil Engineer: Owner: MIDTOWN EAST BLOCK 3 OFFICE 55 Monument Circle, Suite 450 Indianapolis, IN 46204 317-507-6067 F.A. WILHELM CONSTRUCTION COMPANY 3914 Prospect St. Indianapolis, IN 46203 317-359-5411 Civil & Environment Consultants, Inc. 560 E. Ohio Street Suite G Indianapolis, IN 46204 Structural Engineer: McComas Engineering 1717 East 116th Street Suite 200 Carmel, IN 46032 MEP Engineer: Freije 11800 Exit 5 Pkwy Suite 106 Fishers, IN 46037 PERMIT ISSUE 2017-04-24 571 Monon Blvd. Carmel, INKLS CRM 2017-02-27 S501 FRAMING ELEVATIONS MEI 17017MIDTOWN EAST BLOCK 3 OFFICESCALE:S501 1/4" = 1'-0" 2FRAMING ELEVATION SCALE:S501 1/4" = 1'-0" 3FRAMING ELEVATION SCALE:S501 1/4" = 1'-0" 1FRAMING ELEVATION # DESCRIPTION DATE