Loading...
HomeMy WebLinkAbout03100015.6SHINC SPEC; 15 Ll FELT 7/16' DECK 2x8 16' C 1x6 I BOAR 1x8 1 lx2 I BOAR 2' BATT INSULATION Z VALUE — 40 ?x8 CEILING JOIST .6' ON CENTER [6'x4' SOFFIT VENTS 48' ON CENTER VAPOR BARRIER 1/2' GYPSUM WALL BOARD R VALUE — 0.37 SHINC SPEC: 15 LI FELT 7/16' DECK 2x8 16' C 1x6 f BOAR 1x8 f 1x2 f BOAR 1x8 1 L.P. I 1x8 12' BATT INSULATION R VALUE — 40 2x8 CEILING JOIST 16' ON CENTER 16'x4' SOFFIT VENTS 48' ON CENTER VAPOR BARRIER 1/2' GYPSUM WALL BOARD R VALUE — 0.37 ENERGY CODE- R—VALUES NEW WOOL 0R BRICK FACING = 0.80 V AIR SPACE = 1.33 1/2' RIGID INSULATION = 3.5 3 1/2' BATT INSULATION = 13.0 1/2' GYPSUM WALL BOARD = 0.37 TOTAL = 19.0 NEW WOOL OR NEW WOOL 0R 3 1/2' BATT INSULATION 3 1/2' BATT INSULATI❑N AS SHINGLES 12' BATT R VALUE — 13.0 R VALUE — 13 .0 SPE IFIED R VALUE IN 40LATI❑N V AIR SPACE EL B. R❑❑FING 2x8 CEILING JOISTS i' AIR SPACE R VALUE — 1.33 16' ON CENTER R VALUE — 1.33 7/16' O.S.B. ROOF 8'x6' SOFFIT VENTS BRICK FACING BRICK FACING —�\ SHEATHING 48' ON CENTER WITH S—MORTAR WITH S—MORTAR \ F R VALUE — 0.80 00 00 R VALUE 0.80 r, 3/4' T & G DECKING 3/4' T & G DECKING R VALUE - 0,98 R VALUE - 0.98 2x8 RAFTERS 2x4 STUDS o� 16' ON CENTER 16' ON CENTER TYVEK WRAP TYVEK WRAP _ B❑ARDS, FASCIA VAPOR BARRIER T❑TF 2x8 BAN] 2x4 SILL 2' E 5'—C OF IF f USE 9'—C UNB GRA\ 20'x FOO' 4"0 2 0' WALL SECTION #404. 1.1 2x8 OR 2x10 FLOOR JOIST 16' ON CENTER ANCHOR BOLTS 6'-0' ON CENTER 10' POURED CONCRETE F❑UNDATI❑N WALL 1/2' EXPANSION JOINT 4' MINIMUM CONCRETE SLAB R VALUE — 0.44 VAPOR BARRIER 4' MINIMUM GRANULAR FILL R VALUE — 0.92 SCALEt 1/2" =1'-0' TOTE 2x8 BAN] 2x4 SILL 2' 1 5'—F OF IF £ USE 9'—C UNB GRA\ 16'x FOO 4'0 16' WALL SECTION J404.1.1(4) I 2x8 OR 2x10 FLOOR JOIST 16' ON CENTER ANCHOR BOLTS 6'-0' ON CENTER #5 HORIZONTAL REINF❑RCMENT BAR @ 30' ON CENTER #5 VERTICAL REINFORCMENT BAR @ 40' ONCENTER 1/2' EXPANSION JOINT 4' MINIMUM CONCRETE SLAB R VALUE - 0.44 VAPOR BARRIER 4' MINIMUM GRANULAR FILL R VALUE — 0.92 SCALE: 1/2' =1'-0' J 3/8' R.S. PLYWOOD SOFFIT 1/2' GYPSUM WALL BOARD 1x6 R.S, FREEZE R VALUE — 0.37 BOARD ao 0 0 lx8 R,S. PATTERN L.P. LAP SIDING 3 1/2" BATT INSULATION R VALUE — 13.0 1/2'x8' ANCHOR BOLTS 48' ON CENTER TOTAL R VALUE _ (4) COURSE 16'X8' LINE BLOCK 2x4 TREATED A, PLATE 4' CONCRETE SLAB 4' GRANULAR FILL SILL SEALER iu M �' ar►�� 3 1/2' FIBERGLASS BATT INSULATION OR EQUIV, TUFF—N—DRY • +•, �+%'^"'�` WATERPROOFING R VALUE — 3.1 16'x8" CONCRETE °J FOOTING STONE FILL 16' <2) #5 REINFORCING BAR 4' DRAIN TILE TYPICAL WALL SECTION SCALE; 1/2' =1'-0'