Loading...
HomeMy WebLinkAbout03100110.3s D v N 8 NOTICE TO CONTRACTOR rw = OW0,00" "HOLEY MOLEY" "DON ' T SEZ: DIG BLIND" Call Monday thru Friday - 7 am. to 6 pm. 1-800-382-5544 TOLL FREE 1-800-428-5200 OUTSIDE INDIANA PER INDIANA STATE LAW, IT IS AGAINST THE LAW TO EXCAVATE WITHOUT NOTIFYING THE UNDERGROUND LOCATION SERVICE TWO (2) WORKING DAYS BEFORE COMMENCING WORK. EXISTING MONOPOLE TOWER ELEV.= 755.50 FEET (NAVD 88) LATITUDE- 39' 58' 20.34" NORTH LONGITUDE- 86' 04' 10.02" WEST QNAD 83) NEW GPS ANTENNA -FURNISHED BY VERIZON -INSTALLED BY CONTRACTOR -ATTACHED TO ICE BRIDGE POST W/1-1/4- GALVANIZED PIPE & MOUNTING HARDWARE. 18'-0" D-1 S 90' 00' 00" E 60.00' X -X ; rX--..X•-.X-'.X.-X X--•-X.-I �M T1. -.X _-X X. -.X rX'-+X.�•i X _ -1 EXISTING 60'x60' cr . LEASE AREA. . . . . . . . . . . . j I o �. 2 LAJ I I. 0 ■ EXISTING 120' MONOPOLE. •� 1 CENTER s_ . I OF • TOWER NEW ICE BRIDGE & FOUNDATION I - ICE BRIDGE PROVIDED ; <14.. • . • • . BY VERIZON. - FABRICATED & . . . . . . . . . . . INSTALLED BY G.C.. . • . . . . . . o- o - SEE DETAILS ON SHT. S-2. , �' . . . . . . f— q KID . . . . . . . I EXISTING f • . I EQUIPMENT i . . . . . . . I BUILDING I . EXISTING SWING GATE W NO . . . . 3 o Ic; J S_ _ 1. o a'-0 Z....... ......... P14 o X•-• X � w -� X• X +- i -+. i•-• X �� �� X•.�� X -- ■ r ) - X � 3 -- X X i i N 0'00'00" W 60.00' —on 11'-6" L 11'-0" �, 11'-0" EXISTING TELCO PEDESTAL / (5490F) NEW UNDERGROUND TELEPHONE SERVICE. - SEE GENERAL NOTE 6 & 10 ON THIS SHEET. - SEE DETAILS SHEET E-1, E-2 & E-3 NEW CHAIN LINK FENCE FOR METER BOARD STRUCTURE - SEE DETAIL 1 ON D-1. CONTRACTOR SHALL RAISE OR GRADE SITE TO ENSURE POSITIVE DRAINAGE AWAY FROM BUILDING. FOR GEOMETRIC LAYOUT OF OF UTILITY, INGRESS AND EGRESS EASEMENT, ACCESS DRIVE AND LEASE AREA SEE SURVEY. 0 .I NEW VERIZON 11'-6"x 30'-0"x 9'-0" PREFABRICATED RADIO EQUIPMENT BUILDING. (BUILDING DWGS. SUPPLIED BY MANUFACTURER). o -SEE SHEET S-1 00 EXISTING WOOD FENCE TO REMAIN. - NEW FOUNDATION HEIGHT SHALL MATCH TOWER FOUNDATION HEIGHT. EXISTING GRAVEL COMPOUND -SEE DETAIL ON SHEET D-1 CONTRACTOR SHALL INSTALL NEW DOOR CANOPY AFTER o SHELTER IS SET. t M CONTRACTOR SHALL INSTALL NEW CONCRETE STOOP — SEE DETAIL ON SHEET S-1. - NEW UNDERGROUND ELECTRIC SERVICE. - SEE DETAILS ON SHEET E -1,E-2 & E-3 o - SEE GENERAL NOTE 6 & 10 ON THIS SHEET wl c 1 � NEW POWER &TELCO /r E -i 3 33 METER BOARD STRUCTURE. INSTALLED BY CONTRACTOR. 11'-6" 13'-0" CONTRACTOR SHALL STUB OUT NEW CONDUIT FOR TELCO & ELECTRIC EXISTING POWER POLE EXISTING TRANSFORMER (25-1 B 1) DETAILED SITE PLAN 1 " = 10' r O LEGEND +672.5 SPOT ELEVATION O RE -BAR - DRAINAGE LINE • LEASE LINE - CENTERLINE -X -X -_X -X- X -X -i- NEW FENCE LINE POWER POLE W/OVERHEAD ELEC./TELE. NEW UNDERGROUND TELEPHONE =s=======s===== NEW UNDERGROUND ELECTRIC EDGE OF EX. GRAVEL DRIVE GRAVEL COMPOUND NEW PREFABRICATED BUILDING GENERAL NOTES 1, SCHEDULE: THE CONSTRUCTION OF THE SITE REQUIRES A CERTAIN SEQUENCE OF Q, EXISTING UTILITY, GROUNDING, DRAIN OR FIELD TILE DAMAGED EVENTS TO MINIMIZE CONSTRUCTION TIME REQUIRED UNTIL AVAILABILITY SHALL BE REPAIRED OR REPLACED, AS NEEDED, IN LIKE KIND AND OF CELLULAR TELEPHONE SERVICE. VERIFY SCHEDULE DURING BID CHARACTER, AND AT THE EXISTING GRADE PRIOR TO CONSTRUCTION. WALK. 1.L CONTRACTOR'S LICENSE: Z. THE OWNERS REPRESENTATIVE IS• THE GENERAL CONTRACTOR AND ALL OF HIS SUBCONTRACTORS THAT DO CITY OF CARMEL ANY WORK ON THIS PROJECT SHALL BE CURRENTLY LICENSED TO 5490 EAST 126TH STREET PERFORM WORK IN THE LOCATION OF THIS SITE. PROOF OF LICENSES CARMEL, INDIANA 46032 SHALL BE SUPPLIED TO VERIZON WIRELESS PRIOR TO THE CONTACT: MORRIS HENSLEY COMMENCEMENT OF ANY WORK. (317) 571-2639 j,Z, SEEDING: ELECTRIC SERVICE PROVIDED BY: TELEPHONE SERVICE PROVIDED JBL- ALL DISTURBED AREAS SHALL BE REPAIRED AND SEEDED BY THE GENERAL CINERGY AMERITECH CONTRACTOR, UNLESS OTHERWISE NOTED. SEED DISTURBED AREAS MEMBER OF SERVICE DEPARTMENT MEMBER OF SERVICE DEPARTMENT W/4 POUNDS/1000 SQ. FT. - 60% KENTUCKY BLUEGRASS, 18% CREEPING (800) 521-2232 (800) 480-8088 RED FESCUE, 22% ANNUAL RYEGRASS. 3. THE CONTRACTOR INSTALLING THE PLATFORM SHALL ENSURE THAT ONE FACE OF THE PLATFORM ALIGNS WITH TRUE NORTH - SOUTH. DURING THIS WORK, THE GENERAL CONTRACTOR SHALL BE LIMITED TO THE WORK WHICH CAN BE PERFORMED IN THE VICINITY OF THE TOWER. A. ACCESS DRIVEWAY: THE GENERAL CONTRACTOR SHALL UTILIZE THE EXISTING ACCESS DRIVE PER THE ALIGNMENT AS SHOWN ON THESE DRAWINGS. U UPON COMPLETION OF ALL WORK BY THE GENERAL CONTRACTOR AND ALL OF HIS SUBCONTRACTORS ON THIS PROJECT, THE GENERAL CONTRACTOR SHALL STRIP AND CLEAN THE FLOOR OF THE PREFAB BUILDINGS, USING AN INDUSTRIAL STRIPPING MACHINE. THE FINISHED FLOOR SHALL BE CLEAN AND DUST FREE. NO SURFACE FINISHES SHALL BE APPLIED. THE GENERAL CONTRACTOR IS ALSO RESPONSIBLE FOR THE REMOVAL OF ALL EXCESS MATERIAL FROM INSIDE THE SHELTER ALONG WITH SHIPMENT OF NOTED MATERIALS BACK TO THE OWNER. a% PREFABRICATED RADIO EQUIPMENT BUILDING: THE CONTRACTOR SHALL FURNISH, INSTALL AND MAINTAIN ALL REQUIRED THIS CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT AND MATERIALS TRAFFIC CONTROL DEVICES IN ACCORDANCE WITH THE MANUAL OF FOR THE PROPER LIFTING AND TRANSPORTING OF THE PREFABRICATED RADIO UNIFORM TRAFFIC CONTROL DEVICES OR GOVERNING LOCAL AGENCIES. EQUIPMENT BUILDING FROM THE TRANSPORT TRUCK BED TO THE FINAL POSITION ON THE CONCRETE FOUNDATION. THE BUILDING SHALL BE LIFTED INTO PLACE IL CONSTRUCTION STAKING: BY USING FOUR (4) NYLON LIFTING STRAPS CONNECTED TO A SPREADER BAR ASSEMBLY. EACH STRAP SHALL BE RATED AT 55,000#. THE BUILDING WEIGHT THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION STAKING IS 75,000# WITH TELEPHONE EQUIPMENT. CONTRACTOR SHALL ANCHOR THE NEEDED TO COMPLETE ALL THE CONSTRUCTION SHOWN HEREON. BUILDING TO THE CONCRETE SLAB USING STEEL PLATES AND ANCHOR BOLTS PROVIDED BY THE PREFABRICATED RADIO EQUIPMENT BUILDING MANUFACTURER. 1L THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXTREME CAUTION SHALL BE TAKEN IN THE INSTALLATION OF THE BUILDING EXISTING PROPERTY RESULTING FROM THE CONSTRUCTION ACTIVITIES, TO AVOID CONTACT WITH EXISTING OVERHEAD UTILITY LINES, INCLUDING BUT NOT LIMITED TO PAVEMENT, FINISHED GRADES, LANDSCAPING, BUILDINGS, SURVEY MARKERS, ETC. THE CONTRACTOR IS RESPONSIBLE FOR ATTACHING OR SECURING ANY ACCESSORY OR LOOSE ITEMS THAT ARE SHIPPED WITH THE PREFABRICATED RADIO JZ IN THE EVENT ANY DISCREPANCIES OR ERRORS ARE FOUND ON EQUIPMENT BUILDING, I.E. TIE DOWN PLATES, HVAC DRIP HOSES TO BLDG., AND THESE PLANS OR ANY CONFLICT OR PROBLEMS ARE ENCOUNTERED DURING CONSTRUCTION, THE CONTRACTOR SHALL SHALL INCLUDE THIS WORK IN THE BUILDING INSTALLATION PORTION OF THE BID. NOTIFY THE ENGINEER BEFORE PROCEEDING WITH THE WORK. NO ADDITIONAL IL UTILITIES; COMPENSATION WILL BE PAID TO THE CONTRACTOR FOR WORK HAVING TO BE REDONE FOR GRADE OR GEOMETRIC DISCREPANCIES IF NOTICE THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE EXCAVATION AND PROPER TO THE ENGINEER HAS NOT BEEN PROVIDED. THE ENGINEER RESERVES THE RIGHT TO MAKE BACKFILLING OF TRENCHES AND SUPPLY CONDUIT REQUIRED FOR UNDERGROUND MINOR ADJUSTMENTS AS NECESSARY TO ACCOMPLISH THE INTENT OF THESE PLANS. TELEPHONE & ELECTRICAL UTILITIES. ALL TRENCHING SHALL BE COMPACTED TO 95% MAXIMUM DRY DENSITY IN ACCORDANCE W/ASTM D-1557. 11 ALL SITE WORK AND CONSTRUCTION SHALL CONFORM TO ANY THE ELECTRICAL TRENCH SHALL START AT THE NEW PREFABRICATED RADIO EQUIPMENT AND ALL APPLICABLE CODES AND VERIZON WIRELESS STANDARDS AND SPECIFICATIONS. BUILDING AND END AT THE NEW METER BOARD STRUCTURE. THE CONTRACTOR SHALL ALSO STUB THE CONDUIT OUTSIDE THE FENCE 5' IN THE UTILITY EASEMENT. THE 11 ALL ELEVATIONS AND TOPOGRAPHIC INFORMATION WAS TAKEN CONTRACTOR SHALL PROPERLY BACKFILL THE TRENCHES AFTER SETTLEMENT AND SEED FROM A SURVEY SUPPLIED TO GPD ASSOCIATES BY FIRST GROUP ENGINEERING ANY DISTURBED AREAS. CONTACT ELECTRIC PROVIDER SIX WEEKS PRIOR TO CONSTRUCTION INC., GPD HAS NOT VERIFIED THIS INFORMATION AND DOES NOT WARRANT FOR SERVICE AND COORDINATION OF ACCESS TO SITE. ANY INFORMATION SUPPLIED BY OTHERS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ORDERING AND COORDINATING ,$Q. THE CONTRACTOR SHALL MAINTAIN A COMPLETE AS -BUILT SET OF PLANS THE DELIVERY OF A B1 OR POTS TELEPHONE SERVICE LINE TO THE PREFABRICATED RADIO AND CONDITIONS, AND SUBMIT SAME TO THE ENGINEER WITHIN 7 DAYS OF EQUIPMENT BUILDING. THE CONTRACTOR SHALL ALSO COORDINATE DELIVERY OF A T1 CIRCUIT COMPLETION OF CONSTRUCTION. AS -BUILT PLANS SUBMITTED TO THE ENGINEER WITH THE TELCO PROVIDER AND THE VERIZON WIRELESS FACILITY ENGINEER. SHALL INCLUDE A DRAWING WITH DIMENSIONS SHOWING THE LOCATION OF THE THE CONTRACTOR SHALL RUN THE TELEPHONE TRENCH AND CONDUIT FROM THE NEW UNDERGROUND UTILITIES, GROUNDING GRID, BUILDING, TOWER FOUNDATION, TOWER PLATFORM ORIENTATION, AND FENCE PREFABRICATED RADIO EQUIPMENT BUILDING TO THE NEW TELCO METER BOARD STRUCTURE. WITHIN THE LEASE AREA OR PROPERTY AND BE CERTIFIED BY A LICENSED PROFESSIONAL SURVEYOR. THE CONTRACTOR SHALL INSTALL A HOFFMAN BOX AT THE METER BOARD STRUCTURE FOR THE TELCO EQUIPMENT. THE CONTRACTOR SHALL THEN STUB THE CONDUIT OUTSIDE 2..L THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFICATION OF ALL THE FENCE 5' IN THE UTILITY EASEMENT. THE TELCO PROVIDER WILL PROVIDE GOVERNING AGENCIES THAT REQUIRE SITE INSPECTION OF THE WORK AND/OR SERVICE FROM THE RISER POLE TO THE METER BOARD STRUCTURE. THE CONTRACTOR SIMPLY NOTIFICATION. SHALL PROPERLY BACKFILL THE TRENCHES AFTER SETTLEMENT AND SEED ANY DISTURBED AREAS. CONTACT TELCO PROVIDER EIGHT WEEKS PRIOR TO CONSTRUCTION FOR NEW SERVICE. `1��,,,,�tu��u�tr, �. G ,Zi GEOTEXTILE FABRIC: AFTER PLACEMENT AND COMPACTION OF FILL WITHIN THE WORK AREA AND BEFORE THE PLACEMENT OF LIMESTONE AGGREGATE, (SEE SITE AREA SURFACING DETAIL ON D-1). THE ENTIRE DISTURBED WORK AREA SHALL BE COVERED WITH A GEOTEXTILE FABRIC. THIS FABRIC SHALL BE "TREVIRA SPUNBOUND S1125 ENGINEERING FABRIC" INSTALLED ACCORDING TO THE MANUFACTURERS RECOMMENDATIONS. J. TRASH REMOVAL & SANITATION: THE GENERAL CONTRACTOR SHALL REMOVE ALL TRASH AS CREATED BY HIMSELF AND HIS SUBCONTRACTORS. ALL TRASH SHALL BE REMOVED FROM THE SITE IN A TIMELY FASHION TO A LEGAL DISPOSAL AREA. THE GENERAL CONTRACTOR SHALL ALSO REMOVE ALL TRASH CREATED BY OTHER CONTRACTORS INCLUDING CABLE REELS, CARDBOARD BOXES AND PACKING. NO BURNING OF TRASH IS PERMITTED. THE GENERAL CONTRACTOR SHALL PROVIDE AND MAINTAIN A PORTABLE TOILET FOR THE DURATION OF THE CONSTRUCTION PROJECT. S. TOWER: A. THE GENERAL CONTRACTOR SHALL VERIFY THE EQUIPMENT BUILDING FOUNDATION IS LOCATED CORRECTLY WITH RESPECT TO THE TOWER FOUNDATION. THE CONTRACTOR MUST NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO POURING CONCRETE. .-. EXISTING TOWER ANALYSIS BY GPD ASSOCIATES DATED 12-7-01. EXISTING FOUNDATION ANALYSIS BY OTHERS. CONTRACTOR SHALL VERIFY IN WRITING FROM VERIZON WIRELESS THAT ANTENNAS AND EQUIPMENT MOUNTED TO TOWER ARE IN CONFORMANCE WITH THE TOWER ANALYSIS. A. FIELD VERIFY THE LOCATION OF ANY EXISTING UNDERGROUND ELECTRIC AND TELCO PRIOR TO EXCAVATING IN THE VICINITY OF THE SITE. ALL EXCAVATIONS SHALL BE MADE BY HAND OVER OR UNDER OR IMMEDIATELY ADJACENT TO ANY EXISTING UTILITIES & GROUNDING. f, ALL UTILITY COMPANIES SHALL BE NOTIFIED AT LEAST 48 HOURS PRIOR TO ANY CONSTRUCTION ON THIS PROJECT. CONTACT UNDERGROUND UTILITY PROTECTION SERVICE BEFORE YOU DIG AT 1-800-382-5544. L EXISTING UTILITIES ARE SHOWN FROM THE SURVEY AND ARE NOT NECESSARILY COMPLETE AND ACCURATE. THE CONTRACTOR SHALL BE RESPONSIBLE TO LOCATE, EXPOSE AND DETERMINE IF CONFLICTS EXIST WITH THE NEW IMPROVEMENTS. THE CONTRACTOR SHALL NOTIFY THE ENGINEER (GPD ASSOC.) IN ORDER TO RESOLVE ANY CONFLICTS. QtiGNQ 6oaao4o6 ro STATE OF 0 .f�o�sr�9�•, � ie No. b f ARC033977 STATE OF ven wireless GLAUS PYLE SCHOMER BURNS & aEHAVEN INC. I ..................... GPD ASSOCIATES 2647 Waterfront Parkway East Dr. Suite ISO Indianapolis, Indiana 46214 317-299-2996, Fax 317-293-1331 2001006.24 PROD CT TITL 16t & HAZEL DEL CELL SITE CARMEL, INDIANA DESIGN BY: TTP DRAWN BY: TTP DETAILED SITE PLAN CHECKED BY: DATE: TGP SPRINT LEASE AREA SHEET No. 01-04-02 SCALE:_A2 AS NOTED WORK ORDER No. CGSA XXXXXX_ REVISIONS: APPROVALS: SUBJECT: DATE: MGR. LAND & BLDGS. I DIRECTOR - OPERATIONS DIRECTOR - NETWORK SERVICE GENERAL MANAGER I PRESIDENT