Loading...
HomeMy WebLinkAbout03100110.5NOTE: VERIFY BUILDING FOUNDATION DETAILS & UTILITY ENTRANCE OPENING WITH BUILDING MANUFACTURER'S STANDARD FOUNDATION LAN AND DETAILS. PREFABRICATED EQUIPMENT BUILDING WWF 6x6 — W1.4 x W1.4 6" COMPACTED GRANULAR FILL COURSE _ 6" CONCRETE N SLAB-.=—..-�e v. 'v.. v.. v,v v v • • .•Q . • v. • v • 0'0'0 0.0100.01— V v. V 00 0.0 v v =1 I I—� I•:Q • a � =1 LI 1 f l-1 I I �„III=1 .:... '� LAMINATED VAPOR BARRIER FEDERAL III 1'•' : : �:: SPECIFICATIONS UU-B-790A _) MANUFACTURERS QF VAPOR BARRIER: 1. FORTIFIBER CORP. TRACY, CAL. 2. GLAS-KRAFT, INC. "PLYBAR PLUS 11” SLATERSVILLE, R.I. r EXISTING MONOPOLE TOWER 3"x3"x1/4" NEOPRENE RUBBER PAD (60 DUROMETER) - LOCATE AT 3'-0- O.C. MAXIMUM - SHIM W/PLASTIC SHIMS TO ATTAIN UNIFORM BEARING. PADS & SHIMS TO BE SUPPLIED BY SHELTER MANUFACTURER AND INSTALLED BY G.C. GALVANIZED ANCHOR PLATE & 3/4" DIA. WEJ-ITS X 6" LONG (PROVIDED BY BUILDING MANUFACTURER & INSTALLED BY CONTRACTOR) 1" CHAMFER 0 45' (TYP. ) TOP OF FOUNDATION TO MATCH TOWER FOUNDATION FINISHED GRADE "• go o 00 � A. A,a o'qo o ao _I =1 = 7-7 PROVIDE WEED BARRIER OVER ALL I; AGGREGATED�BED Z III 4 REBAR ® V-6" 0/C (VERTICAL) t p o U_ Ln I (6) # 5 REBAR CONTINUOUS o (HORIZONTAL) m CC = 3 UILDING FOUNDATION DETAIL / 1 V 1 # 5 CONTINUOUS AT TOP, MID. F- R^TT # 5 CORNERS A TOP & 801 TYPICAL CORNER REINFORCING yr = i -a " CHAMFER (TYP.) UTSIDE EDGE OF CONCRETE LAB DETAIL CENTERLINE _ OF TOWER W Z W 0 M I r- 5'-0" 1, 3'-1 " I, 6'-6" 2'-0", TYP. ICE BRIDGE STRUCTURE FOUNDATION • I■ /� ■ • 4 3 a4 4. o c 4" PVC TELCO I CONDUIT NOTE: SURFACE OF FINISHED SLAB SHALL BE LEVEL AND FLAT. FOU 11'-6" (LIMITS OF BUILDING AND FOUNDATION) DATION 1" = 5'-0" NOTE: CONCRETE BUILDING STOOP SHALL BE PLACED AFTER EQUIPMENT SHELTER HAS BEEN SET ON FOUNDATION. CONCRETE STOOP SHALL BE CENTERED W/THE DOORWAY OF THE SHELTER. PREFABRICATED EQUIPMENT BUILDING �i rT �� o Qo.0 ooh *• • • BLDG. FDTN. (REINFORCING NOT SHOWN) 5'-0" 1/2" PREMOLDED EXPANSION JOINT SLOPE STONE AWAY FROM MATERIAL. 6" CONC. STOOP WWF 6x6 -W1.4 x W1.4 SLOPE 1/4" PER t0FOOT opo WEED BARRIER EXISTING 9" DRAINAGE FILL 3"x3"0/4" NEOPRENE RUBBER PAD (60 DUROMETER) — LOCATE AT 3'-0" C.C. MAX., SHIM WITH PLASTIC SHIMS TO ATTAIN UNIFORM BEARING. e-% SEE BUILDING MANUFACTURERS o DRAWINGS FOR FOUNDATION Q CONNECTION DETAILS (TOP OF z FOUNDATION SHALL BE 6" o ABOVE EXISTING GRADE.) LL 0 INSIDE EDGE OF o FOUNDATION WALL o BELOW SLAB. m OUTSIDE EDGE OF W FOUNDATION WALL. 0 .., 4" PVC ELECTRIC CONDUIT SEE TYPICAL CORNER REINFORCING DETAIL 2 ON THIS SHEET. #5 x 24x24 DOWELS A 16" O.C. STOOP GRADE o aAo ° o0 2 2 STOOP DETAIL / 3 V 3 - S-� ,/,-a,-O'\A-2AS—i �yttltllltritrl � NSoeso�s �- STATE OF IA�p. 4111111% 1 N O T E S ARC 033917 +' STATE OF `+ »ANP venmmifle/ess 1. LOADINGS: GLAUS PYLE SCHOMER BURNS & DEHAVEN INC. GPD ASSOCIATES FLOOR LIVE LOAD 2647 Waterfront Parkway East Dr. Suite ISO Indianapolis, Indiana 46214 317-299-2996, Fax 317-293-1331 0 I ROOF SNOW LOAD SITE M CARMEL, INDIANA DESIGN BY: 20 PSF DEAD LOADS TTP FOUNDATION DETAILS & NOTES ACTUAL MATERIAL WEIGHTS BASIC WIND SPEED CHECKED BY: TGP SPRINT LEASE AREA #5 x 24x24 DOWELS A 16" O.C. STOOP GRADE o aAo ° o0 2 2 STOOP DETAIL / 3 V 3 - S-� ,/,-a,-O'\A-2AS—i �yttltllltritrl � NSoeso�s �- STATE OF IA�p. 4111111% 1 THE SUBSURFACE REPORT WAS PROVIDED BY ETS GEOTECHNICAL ENVIRONMENTAL ENGINEERI CONSULTANTS DATED SEPTEMBER 24, 1997. REQUIRED BEARING CAPACITY -BLDG. FOOTINGS 1500 PSF THE CONTRACTOR SHALL EXERCISE GREAT CARE DURING EXCAVATION.THE CONTRACTOR SHALL PREDETERMINE UTILITY LOCATIONS AND NOTIFY THE ENGINEER IMMEDIATELY IF DEVIATION FROM PLANS EXIST. THE SUBSURFACE REPORT IS NOT TO BE CONSIDERED AS A COMPLETE RECORD OF THE EXISTING CONDITIONS AT THE SITE. THE CONTRACTOR SHALL VERIFY ALL EXISTING SITE CONDITIONS, INCLUDING SUBSURFACE CONDITIONS. THE CONTRACTOR SHALL OBTAIN PERMISSION FROM THE OWNER PRIOR TO SITE ENTRY FOR THE PURPOSE OF VERIFICATION OF EXISTING CONDITIONS. FOUNDATION SUBGRADES SHALL BE HAND TRIMMED AND COMPACTED. ALL BACKFILL TO BE COMPACTED TO 95% MAXIMUM DRY DENSITY IN ACCORDANCE WITH ASTM D-1557. GROUNDWATER WAS NOTED AT A DEPTH OF 14'-0" DURING DRILLING. GROUNDWATER MAY BE PRESENT DURING ALL CONSTRUCTION/EXCAVATION AND PROVISIONS SHALL BE MADE FOR DEWATERING. 4. CONCRETE WORK: CONCRETE CYLINDERS SHALL BE TAKEN AND TESTED BY A QUALIFIED CONCRETE TESTING COMPANY. THE GENERAL CONTRACTOR SHALL PROVIDE THREE (3) CYLINDER SAMPLES TAKEN PER TRUCK AND THE CONCRETE MUST MEET A 4" SLUMP. THE GENERAL CONTRACTOR SHALL PROVIDE THREE (3) COPIES OF TESTING RESULTS TO VERIZON WIRELESS. FAILURE TO PROVIDE WRITTEN DOCUMENTATION WILL RESULT IN A DEDUCTION FROM THE CONTRACT. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR ANY ADDITIONAL COSTS IN TESTING DUE TO DELAYS BY THE GENERAL CONTRACTOR OR HIS SUBCONTRACTORS. USE AIR ENTRAINMENT IN EXTERIOR SLABS. SPECIFICATIONS - LATEST EDITION OF ACI -318 F'c = 4000 PSI 4" SLUMP - BLDG. FOUNDATION MATERIALS - REINFORCING ASTM A615, GRADE 60 - ANCHOR BOLTS ASTM A307 REINFORCING COVERS - FOOTINGS TOP 2" BOTTOM/SIDES 3" REINFORCING EMBEDMENT AND LAP SPLICES (INCHES) REGULAR BAR SIZE LD SPLICE #4 12 20 #5 15 26 #6 18 31 #7 23 39 CHAMFER TOP CORNERS OF ALL FOUNDATIONS (1-) 5. BURIED CABLE LOCATIONS INFORMATION CONTACT 48 HR. PRIOR TO DIGGING, GRADING, OR DRILLING 1-800-382-5544. vmIIIIIIIII/n.. x osI rE N O T E S ARC 033917 +' STATE OF `+ »ANP venmmifle/ess 1. LOADINGS: GLAUS PYLE SCHOMER BURNS & DEHAVEN INC. GPD ASSOCIATES FLOOR LIVE LOAD 2647 Waterfront Parkway East Dr. Suite ISO Indianapolis, Indiana 46214 317-299-2996, Fax 317-293-1331 100 PSF ROOF SNOW LOAD SITE CARMEL, INDIANA DESIGN BY: 20 PSF DEAD LOADS TTP FOUNDATION DETAILS & NOTES ACTUAL MATERIAL WEIGHTS BASIC WIND SPEED CHECKED BY: TGP SPRINT LEASE AREA 75 MPH 2. STRUCTURAL STEEL: 01-04-02 PIPE - ASTM A53 TYPE E OR S GRADE B, OR ASTM A501. ICE BRIDGE - PROVIDE A ZINC COATING FOR ALL STEEL STRUCTURE REVISIONS: APPROVALS: SUBJECT: DATE: ------- FINISH - AFTER FABRICATION ACCORDING TO ASTM A123. 3. BUILDING FOUNDATION SYSTEM: THE SUBSURFACE REPORT WAS PROVIDED BY ETS GEOTECHNICAL ENVIRONMENTAL ENGINEERI CONSULTANTS DATED SEPTEMBER 24, 1997. REQUIRED BEARING CAPACITY -BLDG. FOOTINGS 1500 PSF THE CONTRACTOR SHALL EXERCISE GREAT CARE DURING EXCAVATION.THE CONTRACTOR SHALL PREDETERMINE UTILITY LOCATIONS AND NOTIFY THE ENGINEER IMMEDIATELY IF DEVIATION FROM PLANS EXIST. THE SUBSURFACE REPORT IS NOT TO BE CONSIDERED AS A COMPLETE RECORD OF THE EXISTING CONDITIONS AT THE SITE. THE CONTRACTOR SHALL VERIFY ALL EXISTING SITE CONDITIONS, INCLUDING SUBSURFACE CONDITIONS. THE CONTRACTOR SHALL OBTAIN PERMISSION FROM THE OWNER PRIOR TO SITE ENTRY FOR THE PURPOSE OF VERIFICATION OF EXISTING CONDITIONS. FOUNDATION SUBGRADES SHALL BE HAND TRIMMED AND COMPACTED. ALL BACKFILL TO BE COMPACTED TO 95% MAXIMUM DRY DENSITY IN ACCORDANCE WITH ASTM D-1557. GROUNDWATER WAS NOTED AT A DEPTH OF 14'-0" DURING DRILLING. GROUNDWATER MAY BE PRESENT DURING ALL CONSTRUCTION/EXCAVATION AND PROVISIONS SHALL BE MADE FOR DEWATERING. 4. CONCRETE WORK: CONCRETE CYLINDERS SHALL BE TAKEN AND TESTED BY A QUALIFIED CONCRETE TESTING COMPANY. THE GENERAL CONTRACTOR SHALL PROVIDE THREE (3) CYLINDER SAMPLES TAKEN PER TRUCK AND THE CONCRETE MUST MEET A 4" SLUMP. THE GENERAL CONTRACTOR SHALL PROVIDE THREE (3) COPIES OF TESTING RESULTS TO VERIZON WIRELESS. FAILURE TO PROVIDE WRITTEN DOCUMENTATION WILL RESULT IN A DEDUCTION FROM THE CONTRACT. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR ANY ADDITIONAL COSTS IN TESTING DUE TO DELAYS BY THE GENERAL CONTRACTOR OR HIS SUBCONTRACTORS. USE AIR ENTRAINMENT IN EXTERIOR SLABS. SPECIFICATIONS - LATEST EDITION OF ACI -318 F'c = 4000 PSI 4" SLUMP - BLDG. FOUNDATION MATERIALS - REINFORCING ASTM A615, GRADE 60 - ANCHOR BOLTS ASTM A307 REINFORCING COVERS - FOOTINGS TOP 2" BOTTOM/SIDES 3" REINFORCING EMBEDMENT AND LAP SPLICES (INCHES) REGULAR BAR SIZE LD SPLICE #4 12 20 #5 15 26 #6 18 31 #7 23 39 CHAMFER TOP CORNERS OF ALL FOUNDATIONS (1-) 5. BURIED CABLE LOCATIONS INFORMATION CONTACT 48 HR. PRIOR TO DIGGING, GRADING, OR DRILLING 1-800-382-5544. vmIIIIIIIII/n.. x osI rE 4Z ARC 033917 +' STATE OF `+ »ANP venmmifle/ess GLAUS PYLE SCHOMER BURNS & DEHAVEN INC. GPD ASSOCIATES 2647 Waterfront Parkway East Dr. Suite ISO Indianapolis, Indiana 46214 317-299-2996, Fax 317-293-1331 PROJE TIT E• 1 & HAZEL DEL CELL SITE CARMEL, INDIANA DESIGN BY: TTP FOUNDATION DETAILS & NOTES DRAWN BY: TTP CHECKED BY: TGP SPRINT LEASE AREA SHEET Not DATE: 01-04-02 S ""' 1 OF SCALE: WORK ORDER No. CGSA AS NOTED REVISIONS: APPROVALS: SUBJECT: DATE: ------- _7 MGR. LAND & BLOGS.DIRECTOR - OPERATIONS DIRECTOR - NETWORK SERVICE GENERAL MANAGER PRESIDENT