HomeMy WebLinkAbout03100110.7g N W �' 4 Ila 7 b'o m PGE: E.C. SHALL FURN. &INST. GROUND ROD (POWER GROUND ELECTRODE) AT 36" BELOW FIN. GRADE. TBG: E.C. SHALL FURN. &INST. 1- #2 AWG BARE SOLID TINNED COPPER GND. WIRE FROM TOWER LEG BASE PLATE TO (EER). CONNECTION TO TOWER LEG BASE PLATE SHALL BE MECHANICAL AND (EER) SHALL BE CADWELD. TEG: E.C. SHALL FURN. &INST. #2 AWG BARE SOLID TINNED COPPER GND. WIRE (TELEPHONE ENTRANCE GROUND) FROM (TGE) THRU INSTALLED 3" PVC CONDUIT TO PLYWOOD TELEPHONE MOUNTING BOARD LOCATED ON BLDG. INTERIOR WALL. CONNECTION TO (TGE) SHALL BE CADWELD AND LOOP AND ATTACH TO PLYWOOD BOARD. TGE: E.C. SHALL FURN. & INST. GROUND ROD (TELCO GROUND ELECTRODE) AT 36" BELOW FIN. GRADE. TWG: E.C. SHALL FURN. & INST. 2 - #2 AWG BARE SOLI oo' TWGG - SEE DETAIL 5 ON E-2. CONTRACTOR SHALL VERIFY EXISTING TOWER SACC f%0ni inln EXISTING TOWE GROUND RING EXISTING MON, NEW ICE BRIDGE SUPPORT (TYP.3) / +V l \ / x x Ll - E-3 x NEW PREFABRICATED RADIO EQUIPMENT BUILDING (BUILDING DWGS. SUPPLIED BY MFR.) x IBOND x x x x x IRDL x I TWG - TO TOWER GROUND RING (TYP. OF 2) TO BE CADWELD. CONTRACTOR SHALL INSTALL NEW GPS ANTENNA, COAX AND DIN FEMALE CONNECTOR GROUND COAX AND ALL ICE BRIDGE POSTS. -x x x x x x/---X-X1 x x SEE INTERIOR/EXTERIOR TWG x CADWELD SG CONNECTION (TYP-) A H x -� SG ACH IRDL GROUND TEST WELL - SEE DETAIL 8 ON E-2. x CEPSG GRE (TYP.) x CSG IBSG HALO FURNISHED WITH BBO TEG x PREFABRICATED RADIO TGE BBG EQUIPMENT BUILDING IRDL IN EER CONDUIT I (TYP ) '-MG B PGE C IRDL EXISTING TELCO PEDESTAL (5490F) GROUNDING DETAIL 1 ON E-2. x x FG ELECTRICAL SITE PLAN 1' = 5' NEW UNDERGROUND ELECTRIC SERVICE - SEE DETAILS ON SHEET E-2, & E-3. - SEE GENERAL NOTE 6 ON SHT. A-2 SEE SERVICE ENTRANCE DETAIL 4 ON SHT. E-2, NEW POWER &TELCO METER BOARD STRUCTURE. - INSTALLED BY CONTRACTOR. - SEE GROUNDING DETAIL 3 ON E-3. CONTRACTOR SHALL STUB UP CONDUIT FOR TELCO & ELEC SERVICE, EXISTING POWER POLE EXISTING TRANSFORMER (25-1 Bl) NEW UNDERGROUND TELEPHONE SERVICE. - SEE DETAIL ON E-2 & E-3. - SEE GENERAL NOTE 6 ON SHT. A-2 7, GROUND BARS (TWGG &CEPSG) SHALL BE 1/4' x 4" x 24" SOLID COPPER. PROVIDE LUG HOLES PER VERIZON STANDARDS. 8. BARE COPPER CONDUCTORS SHALL NOT BE INSTALLED WHERE THEY MAY BE IN CONTACT WITH GALVANIZED METALS. THE CONDUCTORS SHALL BE INSULATED OR ENCLOSED IN PVC CONDUIT OR INSTALLED WITH STANDOFF SUCH THAT NO CONTACT BETWEEN DISSIMILAR METALS MAY TAKE PLACE. 9. CONNECTION OF COPPER CONDUCTORS TO GALVANIZED METAL OR ALUMINUM SHALL BE AVOIDED. BRASS OR STAINLESS STEEL LUGS OR BARS SHALL BE USED FOR THESE CONNECTIONS. 10. NO SHARP 90' BENDS SHALL BE USED. A MINIMUM 12" RADIUS BEND IS ACCEPTABLE. 11. ANTENNA CLAMP RING SHALL BE GROUNDED TO TOWER. 12. ALL GROUNDING SHALL BE IN ACCORDANCE WITH VERIZON WIRELESS SPECIFICATIONS. ACH: E.C. SHALL FURN. &INST. 1 - #2 AWG BARE SOLID TINNED COPPER GND. WIRE FROM THE 2 EXISTING HVAC UNITS TO (EER). CONNECTION TO HVAC UNITS SHALL BE MECHANICAL AND CADWELD TO (EER). BBG: E.C. SHALL PROVIDE AND INSTALL INSULATED #2 AWG STRANDED COPPER GROUND WIRE FROM THE BATTERY BUSS BAR TO THE SHELTER HALO LEAD. CONNECTIONS TO THE HALO LEAD TO BE THREE POINT COMPRESSION CONNECTIONS, CONNECTION TO BATTERY BUSS BAR TO BE MECHANICAL. CONNECTIONS TO GROUND RING TO BE CADWELD. SEE BATTERY BUSS GROUNDING DETAIL ON E-2. BBD: E.C. SHALL FURN. &INST. #2 AWG BARE SOLID TINNED COPPER GND. WIRE, ONE FROM POWER CO. GROUND ELECTRODE (PGE) &ONE TELEPHONE ENTRANCE GROUND (TEG) BOTH TO (EER). CONNECTIONS TO (PGE), (TEG) & (EER) SHALL BE CADWELD. CSG: E.C. SHALL FURN. &INST. 1 - #2 AWG BARE SOLID TINNED COPPER GND WIRE FROM ICE BRIDGE CHANNEL TO (EER). CONNECTION TO ICE BRIDGE CHANNEL AND (EER) SHALL BE CADWELD. CEPSG: E.C. SHALL ATTACH THE GROUND BAR FOR THE COAX ENTRY PROTECTION SYSTEM (AS MFG'D. BY "POLYPHASER CORP., AND SUPPLIED WITH THE BUILDING) TO THE EXTERIOR ELECTRODE GROUND RING (EER) USING CADWELD. REFER TO THE GENERAL INSTALLATION GUIDE AS SUPPLIED WITH SAID POLYPHASER ENTRY ASSEMBLY. EER: E.C. SHALL FURN. &INST. #2 AWG BARE SOLID TINNED COPPER BURIED EXTERIOR ELECTRODE GROUND RING (EER) BURIED AT 36" FG: E.C. SHALL FURN. &INST. 1 - #2 AWG BARE SOLID TINNED COPPER GND WIRE FROM NEW FENCING TO GROUND RING (EER). CONNECTION TO FENCING SHALL BE AT THE BASE OF FENCE POST USING CADWELD AND WEAVE GND. WIRE THRU FABRIC AND ATTACH TO TOP RAIL WITH CADWELD. CONNECTION TO (EER) SHALL BE CADWELD. GG: E.C. SHALL FURN. &INST. 1 - # GROUND NOTES 1. ALL UNDERGROUND CONNECTIONS ON THE LIGHTNING PROTECTION SYSTEM SHALL BE EXOTHERMIC WELDED USING THE CADWELD PROCESS. THE E.C. SHALL FURN. & INST. ALL THESE CONNECTIONS, INCLUDING WELD METALS, MOLDS AND TOOLS. THE E.C. SHALL FURN. & INST. 5/8" x 8' COPPER CLAD STEEL (COPPER JACKET 0.0012" MIN.) GROUND RODS, DRIVEN VERTICAL AND TO BE 36" ® 16'-0" O.C. BELOW FIN. GRADE (OR FROSTLINE, WHICHEVER IS GREATER). 2. THE E.C. SHALL FURN. & INST. No.2 AWG BARE SOLID TINNED COPPER GND. WIRE AT A DEPTH OF 36" BELOW FIN. GRADE FOR THE BUILDING (EER) AND ICE BRIDGE (CSG). 3. ALL EXTERIOR GND. CONNECTIONS SHALL BE EXOTHERMIC CADWELD. 4. ALL MECHANICAL FASTENERS CONNECTIONS TO ALL GROUND BARS SHALL BE LUBRICATED WITH A CORROSION INHIBITER ("OXY -GREASE") OR APPROVED EQUAL. 5. UPON COMPLETION OF THE GROUNDING RING AND BEFORE BONDING TO THE EXISTING RING, THE CONTRACTOR SHALL MEGGER TEST THIS GROUNDING FIELD. THE REQUIRED RESISTANCE LEVEL IS 5 OHMS OR LESS. THE E.C. SHALL NOTIFY THE ENGINEER IF THESE REQUIREMENTS ARE NOT ACHIEVED. THE CONTRACTOR SHALL SUBMIT PRICING TO VERIZON WIRELESS FOR THE INSTALLATION OF ADDITIONAL GROUND RODS REQUIRED FOR PROPER RESISTANCE. UPON APPROVAL FROM VERIZON WIRELESS, THE CONTRACTOR SHALL INSTALL ADDITIONAL GROUND RODS AS REQUIRED. AFTER PASSING TEST, THEN THE CONTRACTOR SHALL BOND THE NEW RING TO THE EXISTING RING. THE CONTRACTOR SHALL NOTIFY VERIZON WIRELESS 48 HOURS PRIOR TO BACKFILLING TRENCHES, POURING CONCRETE FOR FOUNDATIONS AND GUY WIRES, TO INSPECT BONDS AND INSPECT ANY/ALL BREAKS AND REPAIRS TO THE GROUND RING. 6. GROUND SYSTEM SHALL BE VISUALLY INSPECTED BY AN A/E FIRM BEFORE BACKFILLING. 2 AWG BARE SOLID TINNED COPPER GND WIRE AT EACH GATE POST AND PROVIDE GROUND WIRE TO BONDING JUMPER FROM GATE POST TO FENCE POST. GRE: E.C. SHALL FURN. & INST. GROUND RODS TO 36" BELOW FINISH GRADE AT A MINIMUM SPACING OF 16'-0". CONNECTION TO (EER) SHALL BE CADWELD. D TINNED COPPER GND. WIRES FROM TOWER WAVEGUIDE GROUND BAR (TWGG) TO (EER). CONNECTION TO (TWGG) SHALL BE CADWELD AND TO (EER) SHALL BE CADWELD. SEE DETAIL DWG. E-2. TWGG: TOWER WAVEGUIDE GROUND BAR. SEE DETAIL DWG. E-2. TW = o000.00' GENERAL NOTES 1 • UNLESS NOTED OTHERWISE, ALL WORK ITEMS ON SHEETS E-1, E-2 & E-3 SHALL BE PERFORMED BY THE ELECTRICAL CONTRACTOR. 2. THE ELECTRICAL CONTRACTOR SHALL BE LICENSED TO PERFORM WORK IN THE COUNTY OF THIS PROJECT AND SHALL BE RESPONSIBLE FOR OBTAINING AN ELECTRICAL PERMIT FROM THE COUNTY. 3. UNDERGROUND CONDUIT SHALL BE SCH. 40 PVC PLASTIC DUCT WITH ALL BENDS SHALL BE 2' RADIUS 90' SWEEP UNLESS OTHERWISE NOTED ON DRAWINGS. 4. ALL WORK SHALL BE IN ACCORDANCE WITH N.F.P.A. AND N.E.C. CODES, NEMA STANDARDS AND ALL LOCAL CODES. 5. PRIOR TO TRENCHING AND FOR COORDINATING OF THE TELEPHONE AND ELECTRICAL SERVICES, SEE SHEET A-2 GENERAL NOTE #2 FOR UTILITY CONTACT NAMES &PHONE NUMBERS. 6. ABOVE GRADE RISER CONDUIT SHALL BE RIGID SCH. 40 PVC WITH MATCHING FITTINGS. 7. ALL WIRE SHALL BE COPPER, BOON THHN/THWN 90'C UNLESS NOTED OTHERWISE. 8. THE CONTRACTOR SHALL ABIDE BY ALL GUIDELINES REQUIRED BY CROWN CASTLE, INCLUDING BUT NOT LIMITED TO, a) STAGE CONSTRUCTION AND REPORT WHEN ON AND OFF THE SITE. b) PROVIDE LOG BOOK RECORDS OF PERSONNEL ON TOWER. c) PROVIDE R.F. MONITORING DEVICES TO TOWER PERSONNEL. d) CROWN TO INSPECT ALL TRENCHING BEFORE BACKFILLING. 9. THE ELECTRICAL CONTRACTOR SHALL PERFORM ALL WORK SHOWN ON THE CABINET DRAWINGS NOTED "FIELDWORK" OR OTHERWISE NOTED AS WIRING TO BE COMPLETED IN THE FIELD. 10. THE ELECTRICAL CONTRACTOR SHALL VERIFY ELECTRICAL SERVICE REQUIRED - 120/240V, SINGLE PHASE, 200 AMP BEFORE ROUGH IN. 11. THE COPPER WAVEGUIDE ENTRANCE PANEL AT THE WAVEGUIDE ENTRANCE PORT SHALL BE ASSEMBLED USING COPPER JOINT COMPOUND AND BOLTED COMPRESSION CONNECTIONS. THE LOW INDUCTANCE COPPER GROUNDING STRAPS ARE ATTACHED TO THE EXTERIOR OF THE PANEL USING JOINT COMPOUND AND BOLTED TO THE PANEL. THE CONNECTIONS OF THE GROUNDING STRAPS TO THE EARTH ELECTRODE RING ARE VIA A SANDWICH BAR THAT IS COATED W/COPPER COMPOUND (SEE GROUND STRAPS DETAIL ON THIS SHEET) AND BOLTED TO THE STRAPS. THE SANDWICH BAR IS THEN EXOTHERMICALLY WELDED TO THE #2 SOLID BARE TINNED COPPER EARTH ELECTRODE GROUND RING. THE SANDWICH BAR SHALL BE SOLDERED TO PREVENT CORROSION OF THE CONNECTION WHEN IT IS BURIED IN THE GROUND. ALSO IF SOIL CONDITIONS ARE HIGHLY CORROSIVE (SEE SOIL REPORT), SPECIAL TINNED COPPER GROUNDING STRAPS SHALL BE USED AND ARE AVAILABLE THROUGH CLIENT RECOMMENDED MANUFACTURERS. 12. CONTRACTOR SHALL PROVIDE FIRE WATCH DURING ALL WELDING OPERATIONS. TWO (2) HAND HELD 30 LB. FIRE EXTINGUISHER & ADEQUATE WATER SUPPLY SHALL BE APPROVED BY THE CLIENT AND THE TOWNSHIP WATER AUTHORITY. 13. SEAL ALL PENETRATIONS WITH SILICONE SEALANT. LEGEND ACH AIR CONDITIONER GROUND BBG BATTERY BUS GROUND B80 BOND TO BURIED OBJECTS CEPSG COAX ENTRY PROTECTION SYSTEM GROUND CSG CABLE SUPPORT GROUND EER BURIED EXTERIOR ELECTRODE GROUND RING FG FENCE GROUND GG GATE GROUND GRE GROUND ROD ELECTRODE IBSG ICE BRIDGE SUPPORT GROUND IRDL INTERIOR RING GROUND DOWN LEAD MGN MULTI -GROUND NEUTRAL PGE POWER GROUND ELECTRODE TBG TOWER LEG BASE PLATE GROUND TEG TELCO ENTRANCE GROUND TGE TELCO GROUND ELECTRODE TWG TOWER WAVEGUIDE GROUND BAR GND. WIRE TWGG TOWER WAVEGUIDE GROUND BAR • CABLE TO CABLE CADWELD CONNECTION O CABLE TO GND. ROD CADWELD CONNECTION TEST WELL 2001006.24 1 LR, G1STF,9 IBSG: E.C. SHALL FURN. &INST. 1 - #2 AWG BARE SOLID TINNED COPPER GND. WIRE FROM ICE BRIDGE SUPPORT POST TO (EER). CONNECTION STATE OF 6d88p4Q5 STATE OF A�D TO ICE BRIDGE SUPPORT POST & (EER) SHALL BE CADWELD. IRDL: E.C. SHALL CONNECT EXISTING (SUPPLIED WITH BLDG.) #2 AWG BARE � Z SOLID TINNED COPPER GND WIRE DOWN LEAD FROM EXISTING BLDG. INTERIOR GND. HALO TO (EER). CONNECTION TO (EER) SHALL BE GNUS f'YLE SCHOMER BURNS dr pEHAVEN INC. CADWELD. ALSO EC SHALL SEAL ALL EXISTING WALL PENETRATIONS CPD ASSOCIATES WITH WATERPROOF SILICONE SEALANT. 2647 Waterfront Parkway East Dr. Suite 150 Indianapolis, Indiana 46214 MGN: E.C. SHALL FURN. &INST. #2 BARE SOLID TINNED COPPER 317-299-2996, Fax 317-293-1331 CONDUCTOR FROM MAIN A/C SERVICE DISCONNECT SWITCH NEUTRAL & HAZEL DEL CELL SITE BUS BAR TO (PGE). CONNECTION TO (PGE) SHALL BE CADWELD AND CARMEL, INDIANA TO A/C SERVICE DISCONNECT SWITCH NEUTRAL BUS BAR SHALL BE GROUNDING SITE PLAN 8c NOTES MECHANICAL. D TINNED COPPER GND. WIRES FROM TOWER WAVEGUIDE GROUND BAR (TWGG) TO (EER). CONNECTION TO (TWGG) SHALL BE CADWELD AND TO (EER) SHALL BE CADWELD. SEE DETAIL DWG. E-2. TWGG: TOWER WAVEGUIDE GROUND BAR. SEE DETAIL DWG. E-2. TW = o000.00' GENERAL NOTES 1 • UNLESS NOTED OTHERWISE, ALL WORK ITEMS ON SHEETS E-1, E-2 & E-3 SHALL BE PERFORMED BY THE ELECTRICAL CONTRACTOR. 2. THE ELECTRICAL CONTRACTOR SHALL BE LICENSED TO PERFORM WORK IN THE COUNTY OF THIS PROJECT AND SHALL BE RESPONSIBLE FOR OBTAINING AN ELECTRICAL PERMIT FROM THE COUNTY. 3. UNDERGROUND CONDUIT SHALL BE SCH. 40 PVC PLASTIC DUCT WITH ALL BENDS SHALL BE 2' RADIUS 90' SWEEP UNLESS OTHERWISE NOTED ON DRAWINGS. 4. ALL WORK SHALL BE IN ACCORDANCE WITH N.F.P.A. AND N.E.C. CODES, NEMA STANDARDS AND ALL LOCAL CODES. 5. PRIOR TO TRENCHING AND FOR COORDINATING OF THE TELEPHONE AND ELECTRICAL SERVICES, SEE SHEET A-2 GENERAL NOTE #2 FOR UTILITY CONTACT NAMES &PHONE NUMBERS. 6. ABOVE GRADE RISER CONDUIT SHALL BE RIGID SCH. 40 PVC WITH MATCHING FITTINGS. 7. ALL WIRE SHALL BE COPPER, BOON THHN/THWN 90'C UNLESS NOTED OTHERWISE. 8. THE CONTRACTOR SHALL ABIDE BY ALL GUIDELINES REQUIRED BY CROWN CASTLE, INCLUDING BUT NOT LIMITED TO, a) STAGE CONSTRUCTION AND REPORT WHEN ON AND OFF THE SITE. b) PROVIDE LOG BOOK RECORDS OF PERSONNEL ON TOWER. c) PROVIDE R.F. MONITORING DEVICES TO TOWER PERSONNEL. d) CROWN TO INSPECT ALL TRENCHING BEFORE BACKFILLING. 9. THE ELECTRICAL CONTRACTOR SHALL PERFORM ALL WORK SHOWN ON THE CABINET DRAWINGS NOTED "FIELDWORK" OR OTHERWISE NOTED AS WIRING TO BE COMPLETED IN THE FIELD. 10. THE ELECTRICAL CONTRACTOR SHALL VERIFY ELECTRICAL SERVICE REQUIRED - 120/240V, SINGLE PHASE, 200 AMP BEFORE ROUGH IN. 11. THE COPPER WAVEGUIDE ENTRANCE PANEL AT THE WAVEGUIDE ENTRANCE PORT SHALL BE ASSEMBLED USING COPPER JOINT COMPOUND AND BOLTED COMPRESSION CONNECTIONS. THE LOW INDUCTANCE COPPER GROUNDING STRAPS ARE ATTACHED TO THE EXTERIOR OF THE PANEL USING JOINT COMPOUND AND BOLTED TO THE PANEL. THE CONNECTIONS OF THE GROUNDING STRAPS TO THE EARTH ELECTRODE RING ARE VIA A SANDWICH BAR THAT IS COATED W/COPPER COMPOUND (SEE GROUND STRAPS DETAIL ON THIS SHEET) AND BOLTED TO THE STRAPS. THE SANDWICH BAR IS THEN EXOTHERMICALLY WELDED TO THE #2 SOLID BARE TINNED COPPER EARTH ELECTRODE GROUND RING. THE SANDWICH BAR SHALL BE SOLDERED TO PREVENT CORROSION OF THE CONNECTION WHEN IT IS BURIED IN THE GROUND. ALSO IF SOIL CONDITIONS ARE HIGHLY CORROSIVE (SEE SOIL REPORT), SPECIAL TINNED COPPER GROUNDING STRAPS SHALL BE USED AND ARE AVAILABLE THROUGH CLIENT RECOMMENDED MANUFACTURERS. 12. CONTRACTOR SHALL PROVIDE FIRE WATCH DURING ALL WELDING OPERATIONS. TWO (2) HAND HELD 30 LB. FIRE EXTINGUISHER & ADEQUATE WATER SUPPLY SHALL BE APPROVED BY THE CLIENT AND THE TOWNSHIP WATER AUTHORITY. 13. SEAL ALL PENETRATIONS WITH SILICONE SEALANT. LEGEND ACH AIR CONDITIONER GROUND BBG BATTERY BUS GROUND B80 BOND TO BURIED OBJECTS CEPSG COAX ENTRY PROTECTION SYSTEM GROUND CSG CABLE SUPPORT GROUND EER BURIED EXTERIOR ELECTRODE GROUND RING FG FENCE GROUND GG GATE GROUND GRE GROUND ROD ELECTRODE IBSG ICE BRIDGE SUPPORT GROUND IRDL INTERIOR RING GROUND DOWN LEAD MGN MULTI -GROUND NEUTRAL PGE POWER GROUND ELECTRODE TBG TOWER LEG BASE PLATE GROUND TEG TELCO ENTRANCE GROUND TGE TELCO GROUND ELECTRODE TWG TOWER WAVEGUIDE GROUND BAR GND. WIRE TWGG TOWER WAVEGUIDE GROUND BAR • CABLE TO CABLE CADWELD CONNECTION O CABLE TO GND. ROD CADWELD CONNECTION TEST WELL 2001006.24 1 LR, G1STF,9 \ S7 '. = R Q� N0.\000 � STATE OF 6d88p4Q5 STATE OF A�D HIT GNUS f'YLE SCHOMER BURNS dr pEHAVEN INC. CPD ASSOCIATES 2647 Waterfront Parkway East Dr. Suite 150 Indianapolis, Indiana 46214 317-299-2996, Fax 317-293-1331 PROJECT TI E• 126 h & HAZEL DEL CELL SITE CARMEL, INDIANA DESIGN BY: TTP GROUNDING SITE PLAN 8c NOTES DRAWN BY: TfP CHECKED BY: TGP SHEET No. SPRINT LEASE AREA DATE: 01_04.02 - 11 of SCALE: WORK ORDER No. -TC-GSA JE AS NOTED REVISIONS: APPROVALS: SUBJECT: DATE: --T I I _T MGR. LAND & BLDGS. DIRECTOR -OPERATIONS DIRECTOR - NETWORK SERVICE GENERAL MANAGER PRESIDENT