HomeMy WebLinkAbout03100050.1E C HAMILTON CROSSING III SPECIFICATIONS AND GENERAL NOTES 0 0.1 ARCHITECT: k*l c so 280 EAST 96TH STREET, SUITE 200 INDIANAPOLIS, INDIANA 46240 (317) 848.7800 (317) 574.0957 FAX CONTRACTOR: 0.2 0.3 6 Du -- ke REALTY CORPORATION 600 EAST 96TH STREET SUITE 100 INDIANAPOLIS, IN 46240 PHONE: (317) 808-6000 INDEX OF DRAWINGS • COVER CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION • D201 DEMOLTION PLAN • A201 CONSTRUCTION PLAN • A202 REFLECTED CEILING PLAN • A601 ELEVATIONS DETAILS • A602 ELEVATIONS DETAILS • A603 ELEVATIONS DETAILS • A604 ELEVATIONS DETAILS • A801 FINISH PLAN • E201 ELECTRICAL DATA PLAN sawM WE KEYPLAN SCALE: NOT TO SCALE 0.4 0.5 0.6 0.7 1 1.1 1.2 1.3 IA 1.5 1.6 CONTRACT CONDITIONS THE GENERAL CONDITIONS SHAM BE AIA DOCUMENT A201 - 1981 EDITION, ENTITLED 'GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION'. THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED AS FOLLOWS: 3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE PROCEEDING WITH CONSTRUCTION. 3.3 SUPEiWiZ DIRECT AND COORDINAIt THE WORK, WIIF1 SOLE RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MI MS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. 3.7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY GOVERNMENTAL FEES, LICENSES AND INSPECTIONS. 3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND WORKMANSHIP. 10.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES, RULES AND REGULATIONS. ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED PROJECT. WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE SPECIFIED CAPACITIES OF THE EQUIPMENT. WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL GOVERN THE WORK. NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S INTERPRETATION. INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. GENERAL REQUIREMENTS WORK SHALL BE PERFORMED DURING REGULAR BUSINESS hu'bkS WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT. THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURITY, FURNITURE AND 'FURNISHED AND/OR INSTALLED' ITEMS. CONTRACTOR SHALL COORDINATE EXACT LOCATIONS AND SHAM DO THE CUTTING, FITTING, AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS. CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP. SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT TOR THE FOLLOWING ITEMS: .1 METAL FABRICATIONS. .2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS. .3 DOORS, FRAMES AND HARDWARE. .4 SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6' X 6' ACOUSTICAL PANEL ). .5 VCT FLOORING AND BASE ( COLOR SAMPLES ). .6 CARPET ( DYE LOT CUTTING AND SEAMING DIAGRAMS ). .7 PAINT ( 6' X 6' ON ACTUAL SURFACE ). .8 WALLCOVERINGS ( 9' X 9' DYE LOT CUTTING ). .9 SIGNAGE ( SAMPLE SIGN ). .10 LIGHT FIXTURES ( CATALOG CUTS ). TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES, TEMPORARY ENCLOSURES, ARE PROTECTION, HEAT AND POWER WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S AGENT. THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS, TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT W. i ROUT ADDITIONAL CHARGE TO THE PARTY AFFECTED. THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS CONTRACT EXITS, EXIT LIGHTING, ARE PROTECTNE DEVICES AND ALARMS TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS. SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED, SUBMIT THE FOLLOWING INFORMATION: .1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DE )CRIPTIONS OF PRODUCTS, AND FABRICATION AND INSTk ATION PROCEDURES. .2 PROVIDE SAMPLES WHERE APPLICA9'_E OR REQUESTED .3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL CHANGES REQUIRED IN OTHER ELEMDgS OF THE WORK TO ACCOMMODATE THE SUBSTITUTION. .4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL AFFECT THE CONTRACT SUM AND CONTRACT TIME STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING. THE CONTRACTOR SHALL INCLUDE IN HIS B -D AND SHALL ARRAKE FOR HOISTING, CARTING, STANDARD AND 0011WE St�ViCES BY THE BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN REQUIRED DUE TO BUILDING MAWS NENT REQUIREMENTS. 1.12 2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 5 5.1 6 6.1 6.2 6.3 6.4 6.5 6.6 1 �7 SUITE 300 PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL 6.7 MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS Wim CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS. EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE 6.8 DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING, PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND OPERATING FOR TEN DAYS. MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN 6.9 INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE STRAIGHT WITH NO DISTORTIONS. INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL 6.10 JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD. WIDTH NOT TO EXCEED 1/8 U.O.N. 6.11 GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL DEMOLITION OUTLETS. COORDINATE DEMOLITION WITH CONSTRUCTION PLANS TO DETERMINE EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE 7 JOINT SEALERS BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW WORK. 7.1 ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR AND FIXTURES: EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT, .1 'DOW CORNING 786"; DOW CORNING CORP. OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION .2 'SCS 1702 SANITARY; GENERAL ELECTRIC CO. TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND .3 '863 #345 WHITE"; PECORA CORP. SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING .4 'PROGLAZE WHITE'; TREMCO CORP. ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND .5 'OMNIPLUS'; SONNEBORN BUILDING PRODUCTS WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR 7.2 ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING ADDITIONAL WORK RELATED TO SUCH ACTrMES. SURFACES: WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED .1 'CHEM -CALK 600'; BOSTIK CONSTRUCTION PRODUCTS ON. MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL .2 7AC-20'; PECORA CORP. BE INCLUDED. .3 'SONOLAC'; SONNEBORN BUILDING PRODUCTS REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE .4 'TREMCO ACRYLIC LATEX 834'; TREMCO, INC. DRAWINGS. ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE 8 DOORS AND WINDOWS ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND 8.1 INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER. FINISHES, 8.2 INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH. REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR 8.3 DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH NOTED TO BE REPAIRED. AND LOCKSETS. SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS. 8.4 GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS REQUIREMENTS FOR HEAT -STRENGTHENED GLASS. REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK IN SCOPE OF CONTRACT. 9 FINISHES PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS 9.1 GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645. ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT .1 INSTALL 'ELIMINATOR' TYPE HEAD TRACK AT WALLS TERMINATING THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS. AT CEILING. USE PREFORMED OUTSIDE CORNERS. CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY 9.2 GYPSUM BOARD: PROVIDE 5/8' THICK REGULAR AND TYPE ` TAPERED SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE- EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS. DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS PLUMBING, HVAC, ELECTRICAL, AND ARE PROTECTION SYSTEMS ' YS1E MS. .1 DRYWALL FINiSHiNG: COMPLY WITH MANUFACTURER'S PRINTED CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH RECORD SEPIA TO SERVE AS PART OF THE 'AS -BUILT' SET, MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA - PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT, 216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE FINISHING OF GYPSUM BOARD. DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN. 9.4 CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM METAL FABRICATION'S DAMAGED OR SOILED TILES. PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED .1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL REQUIRED TO COMPLETE WORK. REFLECTED CEILING PLAN SHALL GOVERN. .2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN WOOD AND PLASTIC LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS UNLESS NOTED OTHERWISE. CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE "CONSTRUCTION GRADE' LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE 9.5 INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR CONTENT. CASED OPENING UNLESS NOTED OTHERWISE. PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA .1 INSTALL JOHNSONRE TRIM STRIPS AT DOOR WHERE CARPET C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32'. MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND CARPET. PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA C20 AND C27, RESPECTNELY, AND IDENTIFY LUMBER WITH 9.6 RESILIENT FLOORING: CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. A UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS FINISH CARPENTRY AND MILLWORK: COMPLY WITH 'PREMIUM GRADE' AWI ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT STANDARDS. OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO AVOID USE OF CUT WIDTHS LESS THAN 3' AT ROOM PERIMETER, 1 PROiiDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR .2 BASE: AT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID TO FABRICATION OF MULTIPLE UNITS. BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLY(";G WITH NEMA LD 3 AND GP -50 (0.050' NOMINAL THICKNESS). 9.7 USE AN APPROVED CEMENTITIOUS FILLER TO PATCH CRACKS, SMALL HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM .1 EDGE TREATMENT: SAME AS LAMINATE CLAJUING ON HORIZONTAL SURFACE VARIATION OF 'V IN 10 FEET, NON -CUMULATIVE. SURFACES. .2 PROVIDE 2' DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE ELECTRICAL OR DATA OUTLET LOCATIONS, 9.8 CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING STANDARDS: CABINETS: COMPLY WITH AWI SECTION 400 AND ITS DIVISION 4OOB FOR PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS. FLAMMABILITY: ASTM 2859 SURFACE BURNING: ASTM E84 .1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS: SMOKE DENSITY. ASTM E662 GP -50 (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP -28 SOUND ABSORPTION: ASTM C423 (0.028' NOMINAL THICKNESS); EDGES: GP -28 (0.028' NOMINAL FADE RESISTANCE: AATCC 16E THICKNESS). STATIC RESISTANCE: AATCC 134 .2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28. WARRANTY: 10 YEARS 3 CABINET HARDWARE SCHEDULE .1 INSTALL BROADLOOM CARPET BY DIRECT GLUE. .1 HINGES: FULLY CONCEALED, SELF-CLOSING '1000 SERIES" BY GRASS OR EQUAL .2 PULLS: WIRE PROJECTING TYPE, DRILLING 4' ON CENTER, #4483 OR EQUAL AS MANUFACTURED BY STANLEY. 3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH MINIMUM 8 LBS. PULL; ii SP 45 OR SP 46 OR EQUAL AS MANUFACTURED BY STANLEY. Y DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES WITH POSITIVE STOP AND LOCKOUT POSITION, WITH HEAVY-DUTY FULL EXTENSION; #1429 OR EQUAL AS MANUFACTURED BY KNAPE & VOGT. .5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT OR EQUAL =10D, o J0 h L' F:3 Zo IIIIII� � u � F J' N ti ca r� 'dPi1I1C1Nt w M ¢ u N O C dIHSNz oM01 AVID / "13MV0 �0 Allo) " "':"i; CARMEL INDIANA5.1�1112�3S Al!NI'1WW0n �0 1d30 3 U ~ z = c sapoo lU3o1 pue elviS Io O o b a b b 7 Svg suoijuln5aH 11E j1 to aougdL= of laatgng - U u 9.10 PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY, REINSTALL SUCH ITEMS. .1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT SYSTEMS BASED ON DEVOE TO ESTABLISH UUALITY STANDARD FOR THE VARIOUS SUBSTRATES, AS INDICATED. 1. FERROUS METAL A ACRYLIC SEMI -GLOSS ENAMEL FINISH: 1. PRIMER: 1 COAT 141702 METALCLAD ACRYLIC LATEX PRIMER. 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC SEMI -GLOSS ENAMEL 2. NON-FERROUS METAL A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: 1. PRIMER: 1 COAT J41702 METALCLAD ACRYLIC LATEX PRIMER. 2. FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC SEMI -GLOSS FINISH 3. FERROUS STRUCTURE: A. ACRYLIC DRY FOG FLAT FINISH: 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER REDUCIBLE ACRYLIC DRY FOG COATING 4. NON-FERROUS STRUCTURE: A ACRYLIC DRY FOG FLAT FINISH: 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER REDUCIBLE ACRYLIC DRY FOG COATING. 8. WOOD: A ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH: 1. PRIMER: 1 COAT 151701 WONDER -PRIME LATEX PRIMER -SEALER. 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC SEMI -GLOSS ENAMEL B. STAIN -VARNISH RUBBED FINISH: 1. FILLER: 1 COAT #4800 WONDER WOODSTAIN PASTE WOOD FILLER (OPEN GRAIN WOODS). 2. STAIN: 1 COAT J96XX WONDER WOODSTAIN ALKYD STAIN. 3. SEALER: 1 COAT 14900 WONDER WOODSEALER QUICK DRY SEALER. 4. FINISH: 2 COATS #4600 WONDER WOODSTAIN ALKYD SATIN VARNISH. 10. GYPSUM WALLBOARD: A. ACRYLIC LATEX SATIN ENAMEL FINISH: 1. PRIMER: 1 COAT 150801 WONDER TONES LATEX PRIMER -SEALER. 2. FINISH: 2 COATS #35XX WONDER TONE ACRYLIC LATEX SATIN ENAMEL 13. PRECAST CONCRETE: A LATEX TEXTURE COATING -SAND FINISH (WET AREAS) 1. PRIMER: 1 COAT 11502 WONDER -SHIELD ACRYLIC LATEX HOUSE PAINT PRIMER. 2. FINISH: 1 COAT #4 l0i DEV-VO-TEX LATEX TEXTURE COATING. 9.11 WAILCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, CLEAN AND WITHOUT WRINKLES, GAPS OR OVERLAPS. .1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT ACCEPTABLE. .2 SEAMS MUST BE AT LEAST 2" FROM INSIDE CORNERS AND 6' FROM OUTSIDE CORNERS. 10 SPECIALTIES 10.1 ARE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO BUILDING STANDARD, PROVIDE JL INDUSTRIES 'AMBASSADOR" SERIES, SEMI RECESSED, DUO -PANEL, FIELD PAINTED. r a C7r P a .q 1� U abi L UO C v \ v cti Z u u o U 12 FURNISHINGS U �- O° o= v c w 12.1 CASEWORK: O = ¢ y , y J+ U oo Ll L 1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF c Z ` y 05fz Q = FOLLOWING: o a o o e .1 IMPERIAL CABINET CO., INC. � � � a .2 MERILLAT INDUSTRIES, INC. p .3 YORKTOWNE CABINETS 15/16 MECHANICAL AND ELECTRICAL a w v 15/16.1 MECHANICAL (INCLUDING PLUMBING, FIRE PROTECTION AND KV) < ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED of 111 � RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND ELECTRICAL SYSTEMS. 15/16.2 GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF DESIGN/BUILD DRAWINGS FOR ARE PROTECTION, MECHANICAL, AND PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A CERTIFIED ENGINEER. 15/16.3 IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL DRAWINGS SHAM GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK. 15/16.4 SUBMIT ARE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHAH COORDINATE WITH OTHER CEILING COMPONENTS. 15/16.5 DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR OWNER'S AGENT. 15/16.6 OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED. VERILY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED EQUIPMENT. 15/16.7 SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. 15/16.8 DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE INSTALLATION SHALL OCCUR, 15/16.9 DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF OUTLETS, UNLESS OTHERWISE NOTED. 15/16.10 ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD COLOR UNLESS NOTED OTHERWISE IF NO BUILDING STANDARD, PROVIDE IVORY. 15/16.11 WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL PROVIDING PROPER ACCESS TO RECEPTACLES. 15/16.12 IF ADDITIONAL OUTLETS REQUIRED, COORDINATE: WITH ARCHITECTURAL FOR SPECIFIC LOCATION. 15/16.13 CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO OBSERVE PRIOR TO ANY COMMENCEMENT OF 'ROUGH -IN' CONSTRUCTION. n GN GENERAL NOTES GNA CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO PROCEEDING WITH CONSTRUCTION. GN.2 DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: A TO FINISHED FACE OF GYPSUM BOARD. B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS. C. TO TOP OF FINISHED FLOORS. D. TO BOTTOM OF FINISHED CEILINGS. GN.3 SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION, EXISTING CONSTRUCTION AND WALL TYPES. GNA TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED OTHERWISE. GN.5 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH CONSTRUCTION. GN.6 CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT. DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS OBSERVATION. GN.7 FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4' IN 20'-0' NON- CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED. GN.8 CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO CLOSE -IN OF WALLS. GN.9 SOUND INSULATED AND ARE RATED PARTITIONING SHALL BE CAULKED AT PERIMETER WITH ACOUSTICAL OR ARE RATED SEALANT AS APPLICABLE. PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. - PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED i TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL JUNCTION BOXES ARE NOT PERMITTED. GN.10 ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY CONTRACTOR � . fill, AR C0U3u145 I ' 4 STATE OF Y D r 9/24/03 CSO #23318