Loading...
HomeMy WebLinkAbout03110135.1ARCHITECT: CSO 280 EAST 96TH STREET, SUITE 200 INDIANAPOLIS, INDIANA 46240 (317) 848.7800 (317) 574.0957 FAX CONTRACTOR: REALTY CORPORATION 600 EAST 96TH STREET SUITE 100 INDIANAPOLIS, INDIANA 46240 PHONE: (317)808-6200 INDEX OF DRAWINGS tCOVER A201 CONSTRUCTION PLAN & REFLECTED CEILING PLAN A202 ELECTRICAL PLAN & FINISH PLAN ❑ Applue AS StamtD ❑ APPRNM AS W= SMTL i£ ❑ Rt.IM IWEF,HawMM�dl ; ►�1 ►:�t= KEYPLAN SCALE: NOT TO SCALE PARKWOOD FOUR SPECIFICATIONS AND GENERAL NOTES 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 e A 1.8 1.9 1.10 NORTH SUITE 690 INDIANAPOLIS, INDIANA CONTRACT CONDITIONS 1.11 PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL 6.7 MILLWORK SHALL BE FABRICATED FROM FiELD MEASUREMENTS WiTH 9.10 PAINT: USE PRIMER COMPATIBLE WiTH SUBSTRATE. REMOVE OR CLEANERS. CLEAN EACH SURFACE OR UNiT OF WORK TO THE CONDITION PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS. PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY, THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1987 EDITION, EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE 6.8 DO NOT DELIVER CASEWORK AND FiNISH CARPENTRY UNTiL PAINTING, REINSTALL SUCH ITEMS. ENTITLED 'GENERAL CONDITIONS OF THE CONTRACT FOR PROGRAM IN ACCORDANCE WiTH THE MANUFACTURER'S INSTRUCTIONS. WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED CONSTRUCTION'. THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF 1.12 PROVIDE OPERATING AND MAINTENANCE MANUALS WiTH INFORMATION WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY .1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND OPERATING FOR TEN DAYS. SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PXWHRASED MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN 6.9 INSTALL CASEWORK AND FiNISH CARPENTRY PLUMB, LEVEL, TRUE AND FOR THE VARIOUS SUBSTRATES, AS INDICATED. AS FOLLOWS: THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE STRAIGHT WITH NO DISTORTIONS. INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL 6.10 JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM 1. FERROUS METAL 3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD. WIDTH NOT TO EXCEED 1/8 U.O.N. A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE 6.11 GROMMETS ARE TO BE HELD CUT FOR COORDINATION WiTH ELECTRICAL 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC PROCEEDING WiTH CONSTRUCTION. 2 DEMOLITION OUTLETS. LATEX PRIMER, 3.3 SUPERVISE, DIRECT AND COORDINATE THE WORK, WiTH SOLE 2. FINISH: 2 COATS 183XX MIRROLAC-WB ACRYLIC RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS, 2.1 COORDINATE DEMOLITION WiTH CONSTRUCTION PLANS TO DETERMINE SEMI -GLOSS ENAMEL METHODS, TECWQX5, SEU NCES AND PROCEDURES. EXTENT OF WORK. PROVIDE DEMOLITKIN SUFFICIENT FOR SURABLE 7 JW 5EALERS 2. NON-FERROUS METAL 3.7 OBTAIN AND RAY FOR THE Bt81.DfiNG PW NO IECESSAr BONDING/PATCHIM OF EXiSTING CONSTRUCTION TO REMAIN WITH %V A ACRYLIC SEW -GLIAS Eft]. FINISH: GOVERNMENTAL FEES, LICENSES AND INSPECTIONS. WORK. 7.1 ONE -PART MILDEW -RESISTANT SIUCONE SEALANT - AT COUNTERS 1. PRIMER: 1 COAT 141702 METALCLAD ACRYLIC 3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING 2.2 WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR AND FIXTURES: LATEX PRIMER. ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT, .1 'DOW CORNING 786'; DOW CORNING CORP. 2. FINISH: 2 COATS J83XX MIRROLACE-WB ACRYLIC WORKMANSHIP. OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION .2 'SCS 1702 SANITARY; GENERAL ELECTRIC CO. SEMI -GLOSS FINISH 10.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND .3 '863 1345 WHiTE"; PECORA CORP. 3. FERROUS STRUCTURE: PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING .4 'PROGLAZE WHITE"; TREMCO CORP. A ACRYLIC DRY FOG FLAT FINISH: CONTRACTOR'S RESPONSIBILITY, ADJACENT SURFACES, INCLUDING WiTH REGARD TO MATERIALS AND .5 'OMNIPLUS'; SONNEBORN BUILDING PRODUCTS 1. FINISH: 2 COATS 157601 UNI-GRiP-WB WATER WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED REDUCIBLE ACRYLIC DRY FOG COATING WORK MUST COMPLY WiTH APPLICABLE LAWS, CODES, ORDINANCES, TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR 7.2 ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING 4. NON-FERROUS STRUCTURE: RULES AND REGULATIONS. ADDITIONAL WORK RELATED TO SUCH ACTIVITIES. SURFACES: A ACRYLIC DRY FOG FLAT FINISH: ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD 2.3 WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED .1 'CHEM -CALK 600'; BOSTIK CONSTRUCTION PRODUCTS DIV. 1. FINISH: 2 COATS 157601 UNI -GRIP -WB WATER QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL .2 'AC -20'; PECORA CORP. REDUCIBLE ACRYLIC DRY FOG COATING. THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION BE INCLUDED. .3 'SONOLAC'; SONNEBORN BUILDING PRODUCTS 8. WOOD: IN ACCORDANCE WiTH THE INTENTION AND OBJECTIVE OF THE FINISHED 2.4 REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE .4 'TREMCO ACRYLIC LATEX 834'; TREMCO, INC. A ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH: PROJECT. DRAWINGS. 1. PRIMER: 1 COAT 151701 WONDER -PRIME LATEX WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE 2.5 ON EXIST}NG-CONSTRUCTION-TO-REMAIN, THOROUGHLY REMOVE 8 DOORS AND WINDOWS PRIMER -SEALER. SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED 2. FINISH: 2 COATS 183XX MIRROLAC-WB ACRYLIC WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND 8.1 INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS SEMI -GLOSS ENAMEL SPECIFIED CAPACITIES OF THE EQUIPMENT. METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WiTH NEW NOTED OTHERWISE COLOR TO BE SELECTED BY DESIGNER. B. STAIN -VARNISH RUBBED FINISH: WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS FINISHES, 8.2 INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED 1. FILLER: 1 COAT 14800 WONDER WOODSTAIN ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING 2.6 EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH. PASTE WOOD FILLER (OPEN GRAIN WOODS). JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR 8.3 DOOR HARDWARE: BUILDING STANDARD WiTH ADA LEVER HANDLE LATCH 2. STAIN: 1 COAT 196XX WONDER WOODSTAIN GOVERN THE WORK. NOTED TO BE REPAIRED. AND LOCKSETS. ALKYD STAIN. NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE 2.7 SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS. 8.4 GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 3. SEALER: 1 COAT 14900 WONDER WOODSEALER SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN 2.8 REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS REQUIREMENTS FOR HEAT -STRENGTHENED GLASS. QUICK DRY SEALER. DRAWINGS AND SPECIFICATIONS OR WM EITHER EIDIENT NOT REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK 4. FINISH: 2 COATS 14600 WONDER WOODSTAIN CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY IN SCOPE OF CONTRACT. 9 FINISHES ALKYD SATIN VARNISH. OF WORK SHALL BE PROVIDED IN ACCORDANCE WiTH THE ARCHITECT'S 2.9 PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING 10. GYPSUM WALLBOARD: INTERPRETATION. DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS 9.1 GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645. A ACRYLIC LATEX SATIN ENAMEL FINISH: INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WiTH ELEVATOR DOORWAYS, EXiT STAIR DOORWAYS, ETC. CARPET MATS 1. PRIMER: 1 COAT 150801 WONDER TONES LATEX MANUFACTURER'S RECOMMENDATIONS. SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT 1 INSTALL 'ELIMINATOR' TYPE HEAD TRACK AT WALLS TERMINATING PRIMER -SEALER. GENERAL REQUIREMENTS THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS. AT CEILING. USE PREFORMED OUTSIDE CORNERS. 2. FINISH: 2 COATS 135XX WONDER TONE ACRYLIC 2.1 C CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES LATE( SATIN ENAMEL WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY 9.2 GYPSUM BOARD: PROVIDE 5/8' THICK REGULAR AND TYPE 'X' TAPERED 13. PRECAST CONCRETE: A LATEX TEXTURE COATING -SAND FINISH (WET AREAS) WHENEVER POSSIBLE WORK INVOLVING OVERTIME, NON -REGULAR SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE- EDGE GYPSUM BOARD WiTH GALVANIZED STEEL TRIM ACCESSORIES AND BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT. OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE 1. PRIMER: 1 COAT 11502 WONDER -SHIELD AC THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO WiTH ASTM C940 TO THE HIGHEST QUALITY STANDARDS. LATEX HOUSE PAINT PRIMER. INCLUDING BUT NOT LIMITED TO TELEPHONE. DATA, FURNITURE DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS 2. FINISH: 1 COAT #44101 DEV-VO-TEX LATEX CONTRSECURACTOR AND 'FURNISHED AND/ORCA INSTALLED' ITEMS. COE SHALL PLUMBING, HVAC, ELECTRICAL AND FIRE PROTECTION SYSTEMS. .1 DRYWALL FINISHING: COMPLY WiTH MANUFACTURER'S PRINTED TEXTURE COATING. COORDINATE CUTTING, LOCATIONS AND SHALL DO THE CUTTING, TH CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH OF AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE G THAT RECORD SEPIA TO SERVE AS PART OF THE %-BUILT' SET. MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA - WORK WHICH WILL RECEIVE THE WORK OF OTHERS SHOWN OR 2.11 PROVIDE SHORING AND BRACNG, OR SUPPORT TO PREVENT MOVEMENT, 216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND 9,11 WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, CLEAN AND IC REASONABLY IMPLIED 6Y THE DRAWINGS AND SPECIFICATIONS. SEITl.EMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE FINISHING OF GYPSUM BOARD. WITHOUT WRINKLES, GAPS OR OVERLAPS. CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN. ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND 9.4 COUNGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM 1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT WORKMANSHIP. 5 METAL FABRICATIONS DAMAGED OR SOILED TILES. ACCEPTABLE. SUBMIT SHOP DRAWINGS (OR SUBMITTALS) TO THE ARCHITECT FOR THE .2 SEAMS MUST BE AT LEAST 2' FROM INSIDE CORNERS AND 6' FROM FOLLOWING ITEMS: 5.1 PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED .1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS OUTSIDE CORNERS. OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL METAL FABRICATIONS. REQUIRED TO COMPLETE WORK. REFLECTED CEILING PLAN SHALL GOVERN. 10 SPECIALTIES .1 ARCHITECTURAL WOODWORK, INCLUDING TRiM AND CABINETS. .2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN .2 DOORS, FRAMES AND HARDWARE. 6 WOOD AND PLASTIC LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXiT SIGNS 10.1 ARE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO .3 4 SUSPENDED ACOUSTICAL CEILING SYSTEMS (6° X 6' ACOUSTICAL UNLESS NOTED OTHERWISE. BUILDING STANDARD, PROVIDE A INDUSTRIES 'AMBASSADOR' SERIES, PANEL) 6.1 CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE 'CONSTRUCTION SEMI RECESSED, DUO -PANEL FIELD PAINTED. .5 VCT FLOORING AND BASE (COLOR SAMPLES }. GRADE' LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE 9.5 INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR .6 CARPET (DYE LOT CUTTING AND SEAMING DIAGRAMS ). CONTENT CASED OPENING UNLESS NOTED OTHERWISE .7 PAINT (6' X 6' ON ACTUAL SURFACE ). 6.Y PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE .8 V (9' X 9' DYE LOT CUTTING ). EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA .1 INSTALL JOHNSONiTE TRIM STRIPS AT DOOR WHERE CARPET ( SAMNGS SIGNALWALLC .9 SIGNAGE (SAMPLE SIGN C -D PLUGGED INT WiTH EXTERIOR GLUE NOT LESS THAN 15/32*. MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH G .10 LIGHT FIXTURES (CATALOG CUTS ). 6.3 FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND CARPET. PLYWOOD WiTH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITES, C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WiTH 9.6 RESIDENT FLOORING: TEMPORARY ENCLOSURES, ARE PROTECTION, HEAT AND POWER CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR JURISDICTION. .1 UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS THE OWNER'S AGENT'S DIRECTION. COMPLY WiTH SPECIFIC BUILDING 6.4 ° FINISH CARPENTRY AND MILLWORK: COMPLY WITH PREMIUM GRADE AWI ESTABLISHED WiTH PRINCIPAL WAILS, SO THAT TILE AT CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S STANDARDS. OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO AGENT. AVOID USE OF CUT WIDTHS LESS THAN 3' AT ROOM PERIMETER. THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND .1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR .2 BASE: FiT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR TO FABRICATION OF MULTIPLE UMTS. BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS, ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT 6.5 COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WiTH EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE. NEMA LD 3 AND GP -50 (0.050" NOMINAL THICKNESS (' )' 9.7 USE AN APPROVED CEMENTiTIOUS FILLER TO PATCH CRACKS, SMALL THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT .1 EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL SURFACE VARIATION OF V IN 10 FEET, NON -CUMULATIVE. ADDITIONAL CHARGE TO THE PARTY AFFECTED. SURFACES. THE CONTRACTOR SHALL MAINTAIN FOR THE ENTRE LENGTH OF HIS 2 PROVIDE 2' DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE CONTRACT DM, EXiT LIGHTING, FiRE PROTECTIVE DEVICES AND "NIS ELECTRICAL OR DATA OUTLET LOCATIONS, 9.8 CADET: INSTALL CARPETING WHICH MEETS THE FOLLOWING TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS. STANDARDS: SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT 6.6 CABINETS: COMPLY WITH AWI BECTON 4(10 AND ITS DIVISION 4008 FOR PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED, PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS. FLAMMABILITY: ASTM 2859 SUBMIT THE FOLLOWING INFORMATION: SURFACE BURNING: ASTM 084 .1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS: SMOKE DENSITY: ASTM E662 .1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF GP -50 (0.050° NOMINAL THICKNESS); VERTICAL SURFACES: GP -28 SOUND ABSORPTION: ASTM C423 PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES. (0.028' NOMINAL THICKNESS); EDGES: GP -28 (0.028' NOMINAL FADE RESISTANCE: AATCC 16E .2 PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED. THICKNESS). STATIC RESISTANCE AATCC 134 .3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL .2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28. WARRANTY: 10 YEARS CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO •3 CABINET HARDWARE SCHEDULE: ACCOMMODATE THE SUBSTITUTION. .1 INSTALL BROADLOOM CARPET BY DIRECT GLUE. .4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WIL .1 HINGES: FULLY CONCEALED, SELF-CLOSING '1000 SERIES' AFFECT THE CONTRACT SUM AND CONTRACT TIME. BY GRASS OR EQUAL .2 PULLS: WIRE PROJECTING TYPE, DRILLING 4' ON CENTER, STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME 14483 OR EQUAL AS MANUFACTURED BY STANLEY. FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING. .3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WiTH THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR MINIMUM 8 LBS. PULL II SP 45 OR SP 46 OR EQUAL AS HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE MANUFACTURED BY STANLEY. BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN .4 DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS. WITH POSITIVE STOP AND LOCKOUT POSITION, WITH HEAVY-DUTY FULL EXTENSION; #1429 OR EQUAL AS MANUFACTURED BY KNAPE & VOGT. .5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION MOLDED NYLON AND WiTH HEAVY DUTY TWiN SLOTTED SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT OR EQUAL 12 FURNISHINGS 12.1 CASEWORK: .1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: .1 IMPERIAL CABINET CO., INC. .2 MERILLAT INDUSTRIES, INC. .3 YORKTOWNE CABINETS 15/16 MECHANICAL AND ELECTRICAL 15/16.1 MECHANICAL (INCLUDING PLUMBING, FIRE PROTECTION AND HVAC) AND ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND ELECTRICAL SYSTEMS. 15/16.2 GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF DESIGN/BUILD DRAWINGS FOR ARE PROTECTION, MECHANICAL, AND PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A CERTIFIED ENGINEER. 15/16.3 IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S DRAWINGS IN LOCATION OF TERMINAL MATIONS/EQUIPMENT, SUCH AS DIFFUSERS, GRILLES, UGHTS (IF SHOWN ON REFLECTED CEILING PLAN) AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WiTH WORK. 15/16.4 SUBMIT ARE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT SHALL COORDINATE WiTH PATTERN OF LIGHTING LAYOUT AND SHALL COORDINATE WITH OTHER COUNG COMPONENTS. 15/16.5 DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR OWNER'S AGENT. 15/16.6 OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED WiTH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED. VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED EQUIPMENT. 15/16.7 SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. 15/16.8 DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL LO COORDINATE AT THE BEGINNING OF THE PROJECT WiTH THE TENANT AND TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE INSTALLATION SHALL OCCUR, 15/16.9 DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF OUTLETS, UNLESS OTHERWISE NOTED, 15/16.10 ALL SWITCHES AND SWiTCHPLATES SHALL BE BUILDING STANDARD RYLIC COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE IVORY. 15/16.11 WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL PROVIDING PROPER ACCESS TO RECEPTACLES. 15/16.12 IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WiTH ARCHITECTURAL FOR SPECIFIC LOCATION. 15/16.13 CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO OBSERVE PRIOR TO ANY COMMENCEMENT OF 'ROUGH -IN' CONSTRUCTION. GN GENERAL NOTES GN.1 CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO PROCEEDING WITH CONSTRUCTION. GN.2 DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: A TO FINISHED FACE OF GYPSUM BOARD. B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS. C. TO TOP OF FINISHED FLOORS. D. TO BOTTOM OF FINISHED CEILINGS.LO GN.3 SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION, EXISTING CONSTRUCTION AND WALL TYPES. GN.4 TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED OTHERWISE. GN.5 DO NOT SCALE DRAWINGS. WRi7N DIMENSIONS GOVERN. PARTITION LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, C3 NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING WiTH CONSTRUCTION. GN.6 CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT FOR THE ARCHITECT'S OBSERVATION WiTH REGARD TO DESIGN INTENT. DO NOT PROCEED WiTH INSTALLATION OF STUDS WITHOUT THIS OBSERVATION. GN.7 FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4' IN 20'-0' NON- CUMULATiVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED. GN.8 CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO >= CLOSE -IN OF WALLS. GN.9 SOUND INSULATED AND ARE RATED PARTITIONING SHALL BE CAULKED AT PERIMETER WTTH ACOUSTICAL OR ARE RATED SEALANT AS APPLICABLE. PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. PROVIDE WiTH SOUND ATTENUATING INSULATION SECURELY FASTENED TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL JUNCTION BOXES ARE NOT PERMITTED. GN.10 ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY CONTRACTOR. CITY OF CARMEL/CLAY TOWNSIHP Dept. of Community Services -- Building & Code Enforcement One Civic Square 1' Floor; Carmel, fN 46032 (y 11 m� , `\S f �rYF� ! ;1 PLAN AUTHENTICATION CERTIFICATIONS AND AGREEMENT < � +f ®• s As the authorized agent responsible for obtaining a permit or permits', I certify that these plans by the No. areEDEN IDENTICAL to those released i ° s determined r construction that thesedplans theseplansidentical, a STOP 0`23p n Services. I also understand that t �r J ORDEj� will be served, ;,s regti'tred under the Ordinances referenced below. 8z AT E OF W7Printed Name Authorized signature ,r'8isWes 'Required under Chapter 7, Section 10 of the Carmel City Code, entitled "Building Code" and Section 29.42 11 /1/03 and Section 29.4.3 entitled "Administration". Required by Carmel / Clay Township, zoning Ordinance, Section 31.1 entitled ,Violations and Penalties". CSO #23421 ate S :Permits /Forms / Authe n is ticker 1 l -O 1 a� N' 0135