Loading...
HomeMy WebLinkAbout03110125.3REFECTED CEILING PLAN SCALE: 1/8" = V-0" NORTH GENERAL CEILING NOTES: A. ALL WALLS GO TO BOTTOM OF CEILING UNLESS OTHERWISE NOTED. B. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL Al DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY ARE TO BE CONSOLODATED TO A GANG PLATE CONDITION. C. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DESCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. D. MECHANICAL AND ELECTRICAL IS DESIGN -BUILD. DESIGN -BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS AND THERMOSTATS. DESIGN -BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. E. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS, LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CSO INTERIORS REVIEW IS FOR ASTHETIC REVIEW ONLY. F. REPLACE ANY DAMAGED OR MISSING CEILING TILES. NEW TILES TO MATCH EXISTING. GENERAL CONTRACTOR TO VERIFY EXISTING GRID LAYOUT AND CONDITION. G. PATCH, REPAIR, AND/OR REPLACE CEILING GRID SYSTEM WHERE WALLS, LIGHT FIXTURES, OR PARTITIONS HAVE BEEN REMOVED. CEILING GRID SYSTEM TO BE RESTORED TO MATCH EXISTING ADJACENT CONDITION AS TO NOT SHOW LINE OF DEMOLITION. H. RE -USE EXISTING LIGHT FIXTURES WHERE SHOWN. STORE SALVAGED LIGHT FIXTURES DURING THE CONSTRUCTION PHASE. STORAGE OF SALVAGED FIXTURES TO BE COORDINATED WITH OWNER. FIXTURES TO BE CLEANED, RELAMPED, AND INSTALLED UPON COMPLETION OF CONSTRUCTION. I. CEILING HEIGHT IS 9'-0" A.F.F. UNLESS OTHERWISE NOTED. REFLECTED CEILING LEGEND: D EXISTING 2' X 4' FLUORESCENT FIXTURE TO BE REMOVED EXISTING 2' X 4' FLUORESCENT FIXTURE TO REMAIN NEW OR RELOCATED 2' X 4' FLUORESCENT FIXTURE, TO MATCH EXISTING EXISTING DOWNLIGHT TO REMAIN EXISTING CEILING MTD. EXIT LIGHT TO BE REMOVED EXISTING CEILING MTD. EXIT LIGHT W/ DIRECTION INDICATION DUAL -LITE TO REMAIN f® RELOCATED CEILING MTD. EXIT LIGHT W/ DIRECTION INDICATION EXISTING 2 X 2 LAY -IN GRID SUSPENSION SYSTEM NIGHTLIGHT LOCATION $ TWO WAY SWITCH Kalif CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 Fax: 317 808-6797 611 CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Six Parkwood Office 600 East 96th Street, Suite 550 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®COPY69 2oC 0 co O � r u P ,r > m m^ mK K e o a Q 3 Z = Z 0 Z 0Q a M Z Q U CO) - 0 hoz Z OLn :j t:V) at U W ~o V Z D n- O u.)z W W < J o V W Q j oc _ 'L W U 5+ f40. 032035 i, STATE OF I A ` a Drawing Number: 3A202 Of Sheets Duke Job Number: VE Job Number: 23127C