HomeMy WebLinkAbout03110126.2DEMOLITION PLAN SCALE: 1/8" = 1'-0" (9 NORTH CONSTRUCTION PLAN SCALE: 1/8" = V-0" (9 NORTH DEMOLITION LEGEND: EXISTING DUPLEX WALL OUTLET TO BE DEMOLISHED EXISTING QUADRAPLEX WALL OUTLET TO BE DEMOLISHED WALL LEGEND: = = = = EXISTING PARTITION TO REMAIN TYPICAL WALL TYPICAL AT ALL EXTERIOR WALLS— 5/8- TYPE X G.W.B. FINISH BELOW EXISTING WINDOW SILL COVER METAL STUD EXISTING CONSTRUCTION TO BE REMOVED DENOTES AREA NOT IN CONTRACT PREFINISHED ALUMINUM RECEIVER TRIM "GB350" — FASTEN AT WINDOW SILL & SET IN A CONTINUOUS BEAD OF ACOUSTICAL SEALANT. TRIM COLOR TO MATCH BLDG. WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT MULLION DETAIL SCALE: 1/2" = V-0" 1 /2"HW, 1 /2"CW, & 1-1 /4"V CONNECT TO BUILDING MAINS SINK TO BUILDING DRAIN PLUMBING 2� ISOMETRIC 1 SCALE: N.T.S. WALL LEGEND: NOTES: _ _ = EXISTING CONSTRUCTION TO BE REMOVED NEW PARTITION EXISTING WALL TO REMAIN ® NEW LOW WALL PARTITION W1 2-1/2" 25 GAUGE METAL STUDS ®24"O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. W2 2-1/2" 25 GAUGE METAL STUDS @24-O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. PROVIDE 2 1/2" SOUND INSULATION IN HORIZONTAL SURFACE ABOVE CEILING AND INSIDE WALL. INSULATION TO EXTEND 2'-0" IN BOTH DIRECTIONS FROM CENTER LINE OF WALL. W3 NEW LOW WALL CONSTRUCTION TO BE 48" A.F.F.: 2-1/2" 25 GAUGE METAL STUDS ®16"0.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. �1�1_ WALLS TO EXTEND TO + 48" A.F.F. PROVIDE WOOD CAP TO BE PAINTED (PX). W4 2-1/2" 25 GAUGE METAL STUDS ®24" O.C. �OT WITH 5/8" GYPSUM WALL BOARD ONE SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. W5 2-1/2" 25 GAUGE METAL STUDS ®24"O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO STRUCTURAL DECK. PROVIDE 2 1/2" SOUND INSULATION IN HORIZONTAL SURFACE ABOVE CEILING AND INSIDE WALL. W6 2-1/2" 25 GAUGE METAL STUDS ®24"O.C. WITH 1/16" LEAD LINED GYPSUM WALL BOARD ONE SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. ® DENOTES AREA NOT IN CONTRACT DENOTES NEW MILLWORK o NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE ON 1A801. GENERAL DEMOLITION NOTES: A. DEMOLISH EXISTING WALLS THAT ARE SHOWN DASHED, BACK TO A POINT WHEREAS A SMOOTH SURFACE REMAINS FOR INSTALLATION OF NEW FINISHES. B. REMOVE ELECTRICAL AND DEVICE LINES IN WALLS THAT ARE SHOWN DASHED INCLUDING ALL ATTACHED WIRING. DEMOLISH ELECTRICAL DEVICES AND WIRING BACK TO A POINT WHEREAS PROPER PREPARATION FOR NEW FINISHES IS POSSIBLE. SEE ELECTRICAL AND FINISH PLANS FOR MORE INFORMATION. C. REMOVE ALL WALLS, MILLWORK, DOORS, AND DOOR FRAMES AS SHOWN DASHED. RESERVE DOORS AND DOOR FRAMES FOR RE—USE IN NEW PROJECT SCOPE. D. REMOVE EXISTING FINISHES WHERE NEW FINISHES ARE TO BE INSTALLED. REFERENCE FINISH SHEET, A801, TO COORDINATE LOCATIONS OF NEW FINISHES E. REMOVE ALL EXISTING FLOOR OUTLETS SHOWN. PROVIDE AN EVEN FLOOR SURFACE IN PREPARATION FOR NEW FLOOR FINISH. F. ALL EXISTING BLINDS AT PERIMETER WINDOW LOCATIONS ARE TO BE CLEANED AND REPAIRED IF NECESSARY AT PROJECT COMPLETION. G. SAVE ALL ITEMS REMOVED FROM THE SPACE PER OWNERS DIRECTION UNLESS OTHERWISE NOTED. GENERAL CONSTRUCTION NOTES: A. DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY DESIGNER— DO NOT SCALE DRAWINGS. B. PROVIDE WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. C. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). D. REFER TO CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES. E. REUSE DOORS, FRAMES, AND PARTITIONS SYSTEMS AS MUCH AS FEASIBLE. VERIFY WITH WITH ARCHITECT AND OWNER ANY ITEMS WHICH ARE QUESTIONABLE FOR REUSE. F. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL. G. APPLY SEALANT AT ALL PLUMBING FIXTURES AT JUNCTURE WITH WALL AND AT ALL COUNTERTOPS AND BACKSPLASH JUNCTURES. H. ALL WALLS SHALL BE CHAULKED OFF FOR DESIGNER'S REVIEW OF NEW WALL CONSTRUCTION I. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE OF DOOR UNLESS NOTED OTHERWISE TO MEET CURRENT ADA CODE REGULATIONS J. ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE PATCHED, REPAIRED AND SANDED SMOOTH IN PREPARTION FOR NEW FINISHES. K. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. L. BUILDING OWNER AND/OR G.C. TO PROVIDE MINISBLINDS AT ALL PERIMETER WINDOWS. EXISTING MINIBLINDS TO BE CLEANED AT COMPLETION OF CONSTRUCTION, M. ALL NEW AND EXISTING FIRE EXTINGUISHER CABINETS TO BE INSTALLED ACCORDING TO CODE. LIFSAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER LOCATIONS ARE NEEDED A PLAN MUST BE SUBMITTED TO THE DESIGNER FOR REVIEW OF AESTHETIC PURPOSES ONLY. N. EXISTING DOORS AND DOOR FRAMES TO BE REUSED DURING CONSTRUCTION DOORS THAT ARE QUESTIONABLE FOR REUSE, PLEASE CALL FOR DESIGNERS REVIEW AND APPROVAL OF REUSE BEFORE INSTALLATION. 0. ALL NEW WORKSURFACES TO RECIVE 2-1/2" GROMMETS. NEW GROMMET LOCATIONS TO BE VERIFIED WITH TENANT IN FIELD AND WITH RESPECT TO NEW ELECTRICAL LAYOUT P. CORNER GUARDS TO BE INSTALLED AT ALL HALLWAY CORNER LOCATIONS. MFG: KOROGARD, PRODUCT NUMBER: G100, G101. COLOR: K-46 WHITE CORN. CONSTRUCTION PLAN NOTES: FP1 ALIGN FINISHED FACES. FP2 CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS USE SEALANT AT MULLIONS FOR SOUND INSULATION. VERIFY DIMENSION FROM MULLION TO MULLION AND REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING WITH CONSTRUCTION, REFERENCE DETAIL 1/1A201. �3 NEW OR RELOCATED RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION WITH TOP OF CABINET AT 54" AFF. �a PROVIDE 1/4" COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED ICE MAKER/REFRIGERATOR. VERIFY EXACT LOCATION OF ALL APPLIANCES, REQUIRING A WATER SOURCE WITH TENANT. OREFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER. �e PROVIDE 3/4" x 4' x 8' FIRE RETARDANT PLYWOOD PHONE BOARD. PHONE BD. PAINTED WITH FIRE RETARDANT PAINT, COLOR OF PAINT TO MATCH ADJACENT WALL FINISH. O PROVIDE ALTERNATE PRICE FOR BUILT—IN PLASTIC LAMINATE COUNTERTOP ® 42" AFF. MAT611 GONFERENGE ROOM DOOR. 0FIREWIDE WOOD SLIDE 99OR PASS T''RU AT T -I IS LOGATION. WW9 BOOR & TRIM TE) — NOT USED. O PROVIDE 36" WHITE VANITY W/ CULTURED MARBLE TOP. �a PROVIDE PLASTIC LAMINATE COUNTERTOP AT THIS LOCATION. REFERENCE SECTION 5/1A601. CURTAIN AND TRACKS TO BE RELOCATED FROM PREVIOUS SPACE TO THIS LOCATION. EXACT LOCATION TO BE DETERMINED BY TENANT. ,z BUILD BULKHEAD ABOVE WITH STORE FRONT GLASS SYSTEM BELOW. ,s PROVIDE BLOCKING FOR 6' LONG COAT RACK. EXACT LOCATION TO BE DETERMINED BY TENANT. COAT RACK TO BE PROVIDED BY TENANT AND INSTALLED BY G.C. UNDERCOUNTER GARBAGE DISPOSAL TO BE PROVIDED AND INSTALLED BY G.C. REQU REMENTSDWITHO POWER NUFOACTURERpS GARBAGE DISPOSAL. VERIFY ELECTRICAL ,s G.C. TO INSTALL TENANT PROVIDED DISHWASHER. G.C. TO CONFIRM UNIT IS IN WORKING ORDER AND IS NOT LEAKING BEFORE TURNING UNIT OVER TO TENANT. EX—RAY VIEW BOX ELECTRICAL PROVIDED AND LOCATION DETERMINED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR X—RAY BOX. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER. 17 PROVIDE PLASTER TRAP IN SINK AT THIS LOCATION. ,e PROVIDE UTILITY SINK AT THIS LOCATION. ,e PROVIDE HANDICAP ACCESSIBLE, ELECTRICAL DOOR AT THIS LOCATION. PROVIDE SPECIMEN PASS—THRU CABINET. SPECIMEN PASS—THRU CABINET SHALL BE BRADLY MODEL 9813. X21 PROVIDE BLOCKING IN WALL FOR TENANT PROVIDED MARKER BOARD. EXACT LOCATION AND HEIGHT TO BE DETERMINED BY TENANT. ® PROVIDE 18"X24" LEAD WINDOW AND FRAME. SEE ELEVATION 13/1A601 FOR DETAIL. El REALTY CO600 East 9Suite 100 Indianapolis,Phone: (317Fax: (317) I CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Six Parkwood Office 600 East 96th Street, Suite 550 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 @Copyr 9ht 200 L6 0 L^, 2 a � MV o� r C 7_7 r 3 o � U z a � D a 0. z OC O C3 P z V z N F— J � N Z CO z W O = z�W V O5: z or - ~Q 016 a� ...I U z O J W O W Certified By: ®``';1E1eesaarr11ry R ... �i . o............ s r F4F = No. = AR00910036 STATE OF 6 r Drawing Number: 1A201 Of Sheets Duke Job Number: A/E Job Number: 23126 I