HomeMy WebLinkAbout03110126.3REFLECTED CEILING PLAN SCALE: 1/8" = 1'-0(9" NORTH ELECTRICAL PLAN SCALE: 1/8" = 1'-0" (3 NORTH REFLECTED CEILING LEGEND: EXISTING 2' X 4' FLUORESCENT FIXTURE TO BE REMOVED NEW OR RELOCATED 2' X 4' FLUORESCENT FIXTURE, TO MATCH BUILDING STANDARD EXISTING 2' X 4' FLUORESCENT FIXTURE TO REMAIN Ii Q !_ NEW INCANDESCENT DOWNLIGHT L01 EXISTING INCANDESCENT DOWNLIGHT t NEW CEILING MTD. EXIT LIGHT W/ DIRECTION INDICATION EXISTING 2 X 2 LAY -IN GRID SUSPENSION SYSTEM NEW 2 X 2 LAY -IN GRID SUSPENSION SYSTEM. MFG: USG INTERIORS, STYLE: ECLIPSE CLIMAPLUS, PEDESTAL IV PANELS. WALL SCONCE. MFG:HAMPSTEAD LIGHTING, VISTOSI GROUP. CODE: EDO SCONCE, GLASS:WHITE, LIGHT:100W E26. NEW TWO WAY SWITCH �D NEW DIMMER SWITCH �3 NEW THREE-WAY SWITCH NL NIGHTLIGHT LOCATION REFLECTED CEILING NOTES: cP1 TENANT TO PROVIDE OVERHEAD SURGICAL LIGHT AT THIS LOCATION. G.C. TO PROVIDE POWER FOR SURGICAL LIGHT. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER. EXACT LOCATION TO BE DETERMINED BY TENANT. CP2 ADD EXHAUST FAN ON SEPARATE SWITCH. cP3 PROVIDE UPS AND BRANCH PANEL. EXACT LOVATION TO BE DETERMINED BY TENANT. cPa EXACT LOCATION OF CAN LIGHTS TO BE CORRIDINATED WITH TENANT IN THE FIELD. cP5 EXHAUST FAN TO BE ADDED ON T—STAT CONTROL. cas CEILING HEIGHT IN THIS ROOM TO BE RAISED TO 9'-0". GENERAL ELECTRICAL NOTES: A. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX PULL AND STRING AT AT PHONE AND DATA LOCATIO S AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. B. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. C. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIABLE WITH TENANT EQUIPMENT. D. FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO COORDINATE ELECTRICAL LOCATIONS AND CIRCUITING REQUIREMENTS WITH TENANT AND/OR FURNITURE DEALERSHIP FOR SYSTEMS BASE FEED AND/OR POWER POLES. ELECTRICAL CONTRATOR TO HARDWIRE FURNITURE SYSTEM TO BUILDING POWER SOURCE. E. ALL RECEPTACLES THAT ARE SHOWN DASHED ARE TO BE REMOVED FROM EXISTING WALLS AND SHALL BE PATCHED AND REPAIRED WITH DRYWALL PRIOR TO NEW WALL FINISH. F. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED ® 18" A.F.F. UNLESS OTHERWISE NOTED. ELECTRICAL PLAN NOTES: E1 PROVIDE DEDICATED POWER FOR COPIER. ELECTRICAL CONTRACTOR TO VERIFY POWER REQUIREMENTS WITH TENANT EQUIPMENT. O FLOOR TO BE TRENCHED FOR FLUSH MOUNTED ELECTRICAL AND DATA BOX TO BE INSTALLED. EXACY LOCATION TO BE DETERMINED BY TENATE. E3 ALL POWER AND LIGHTING TO RUN TO SEPARATE SINGLE PHASE BREAKER PANEL. Ea 240 VAC, 100 AMP SINGLE PHASE DISCONNECT LOCATED 60" AFF AT THIS LOCATION. Es J -BOX LOCATED DIRECTLY UNDER DISCONNECT. PROVIDE REMOVABLE COVER WITH KNOCK OUT. J -BOX TO INCLUDE 20 AMP, 110 VOLT LINE. Es J -BOX LOCATED DIRECTLY UNDER LEAD WINDOW. PROVIDE REMOVABLE COVER WITH KNOCK OUT. O DUPLEX OUTLET NOT TO RUN TO SEPARATE SINGLE PHASE BREAKER PANEL. GENERAL CEILING NOTES: A. ALL WALLS GO TO BOTTOM OF CEILING UNLESS OTHERWISE NOTED. B. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY ARE TO BE CONSOLODATED TO A GANG PLATE CONDITION. C. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DESCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. D. MECHANICAL AND ELECTRICAL IS DESIGN -BUILD. DESIGN -BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS AND THERMOSTATS. DESIGN -BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. E. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CSO INTERIORS REVIEW IS FOR ASTHETIC REVIEW ONLY. F. REPLACE ANY DAMAGED OR MISSING CEILING TILES. NEW TILES TO MATCH EXISTING. GENERAL CONTRACTOR TO VERIFY EXISTING GRID LAYOUT AND CONDITION. G. PATCH, REPAIR, AND/OR REPLACE CEILING GRID SYSTEM WHERE WALLS, LIGHT FIXTURES, OR PARTITIONS HAVE BEEN REMOVED. CEILING GRID SYSTEM TO BE RESTORED TO MATCH EXISTING ADJACENT CONDITION AS TO NOT SHOW LINE OF DEMOLITION. H. RE -USE EXISTING LIGHT FIXTURES WHERE SHOWN. STORE SALVAGED LIGHT FIXTURES DURING THE CONSTRUCTION PHASE. STORAGE OF SALVAGED FIXTURES TO BE COORDINATED WITH OWNER. FIXTURES TO BE CLEANED, RELAMPED, AND INSTALLED UPON COMPLETION OF CONSTRUCTION. I. CEILING HEIGHT IS 8'-6" A.F.F. UNLESS OTHERWISE NOTED. J. ACTYLIC LENS LIGHT FIXTURES TO BE USED THROUGHT THE SPACE. ELECTRICAL LEGEND: SYMBOL CSO DESCRIPTION d) NEW _ DUPLEX WALL OUTLET 6 NEW QUADRAPLEX WALL OUTLET 6D NEW DEDICATED CIRCUIT OUTLET 17 NEW PHONE/DATA WALL OUTLET (BOX AND PULL STRING) 8GFI NEW GROUND FAULT INTERUPT CIRCUIT OUTLET E EXISTING QUADROPLEX O NEW FLOOR MOUNTED DUPLEX/TELEPHONE OUTLET �- NEW J -BOX SIZE: 4" X 4" ®- NEW J -BOX SIZE: 12" X 12" 600 D-W WA REALTY CORPORAnON East 96th Street Suite 100 Indianapolis, IN 46240 ?hone: 317 808-6000 Fax. 317 808-6797 JI r r I r r CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Slx Parkwood Office 600 East 96th Street, Suite 550 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 OCopYright 2001 1= 0 T) Q) R O C ' m T� it C-1� U Z Q .J a a D J 0 a (� CID E' Z _ V _ cr) W �..., Nz Q 0No J W J df W _ Z�w a 0-M z Z LI) J Q v rW' � W V W J U. W Certified By: -r/rrr R +7u C'1 Q�'.�G1STE'q• sp or r No. „ AR00910036 dw STATE OF il!iV 4� Drawing Number: 1A202 if Sheets Duke Job Number: A/E Job Number: 23126 JI r r I r r