Loading...
HomeMy WebLinkAbout03090071.1ARCHITECT: kal C so 600 E. 96TH STREET, SUITE 550 INDIANAPOLIS, INDIANA 46240 1317) 848.7800 (317) 574.1E169 FAX CONTRACTOR: 1AW A or Duke REALTY CORPORATION 4225 NAPERVILLE ROAD SUITE 150 LSILE, IL 60532 PHONE: (630)577-7900 INDEX OF DRAWINGS • COVER 6.7 • A201 DEMOLTION & CONSTRCUTION PLAN • A202 REFLECTED CEILING & ELECTRICAL_ PLAN • A601 ELEVATIONS SECTIONS • A801 FINISH PLAN & DOOR SCHEDULE EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE 6.8 DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTiL PAINTING, REINSTALL SUCH ITEMS. 12.1 CASEWORK: PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED ❑ APPROVED AS SUBMITTED APPROVED AS NOTED 71 REJECTED SIGNATURE DATE COMPANY KEYPLAN _ SCALE: N.T.S. 9 NORTH M ERI PIAN HAMILTON CROSSING SPECIFICATIONS AND GENERAL NOTES 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 1 1.1 1.2 1.3 1.4 1.5 1.6 CONTRACT CONDITIONS THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1987 EDITION, ENTITLED 'GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION'. THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED AS FOLLOWS: 3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE PROCEEDING WiTH CONSTRUCTION. 3.3 SUPERVISE, DIRECT AND COORDINATE THE WORK, IIRTH SOLE RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. 3.7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY GOVERNMENTAL FEES, LICENSES AND INSPECTIONS. 3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND WORKMANSHIP. 10.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. WORK MUST COMPLY WiTH APPLICABLE LAWS, CODES, ORDINANCES, RULES AND REGULATIONS. ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION IN ACCORDANCE WiTH THE INTENTION AND OBJECTIVE OF THE FINISHED PROJECT. WHEN NOT INDICATED iN THE CONTRACT DOCUMENTS, PROVIDE THE SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE SPECIFIED CAPACITIES OF THE EQUIPMENT. WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHAM GOVERN THE WORK. NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY OF WORK SHALL BE PROVIDED IN ACCORDANCE WiTH THE ARCHITECT'S INTERPRETATION. INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WiTH MANUFACTURER'S RECOMMENDATIONS. GENERAL REQUIREMENTS WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT. THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURITY, FURNITURE AND 'FURNISHED AND/OR INSTALLED' ITEMS. CONTRACTOR SHALL COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FiTTING, AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR REASONABLY IMPUED BY THE DRAWINGS AND SPECIFICATIONS. CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP, SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE FOLLOWING ITEMS: .1 METAL FABRICATIONS. .2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS. .3 DOORS, FRAMES AND HARDWARE. .4 SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6' X 6' ACOUSTICAL PANEL ). .5 VCT FLOORING AND BASE ( COLOR SAMPLES ). .6 CARPET ( DYE LOT CUTTING AND SEAMING DIAGRAMS ). .7 PAINT ( 6" X 6" ON ACTUAL SURFACE ). .8 WALLCOVERiNGS ( 9' X 9' DYE LOT CUTTING ). .9 SIGNAGE ( SAMPLE SIGN ). .10 LIGHT FIXTURES ( CATALOG CUTS ). TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES, TEMPORARY ENCLOSURES, PRE PROTECTION, HEAT AND POWER WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR THE OWNER'S AGENTS DIRECTION. COMPLY WITH SPECIFIC BUILDING CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S AGENT. THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS, TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SiTE. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES ATTRIBUTABLE TO HiS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT ADDITIONAL CHARGE TO THE PARTY AFFECTED. THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS CONTRACT EXITS, EXIT LIGHTING, ARE PROTECTIVE DEVICES AND ALARMS TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS. SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED, SUBMIT THE FOLLOWING INFORMATION: .1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES. .2 PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED. .3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO ACCOMMODATE THE SUBSTITUTION. .4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL AFFECT THE CONTRACT SUM AND CONTRACT TIME. STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING. THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS. 1.12 2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 5 5.1 6 6.1 6.2 6.3 6.4 6.5 6.6 H EAL7H SUITE 12772 CARMEL, INDIANA 03(:x1Oo7f PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL 6.7 MILLWORK SHALL BE FABRICATED FROM HELD MEASUREMENTS WITH 9.10 PAINT: USE PRIMER COMPATIBLE WiTH SUBSTRATE. REMOVE OR 12 FURNISHINGS CLEANERS. CLEAN EACH SURFACE OR UNiT OF WORK TO THE CONDITION PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS. PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY, EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE 6.8 DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTiL PAINTING, REINSTALL SUCH ITEMS. 12.1 CASEWORK: PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY .1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT .1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND OPERATING FOR TEN DAYS. SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD FOLLOWING: MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN 6.9 INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND FOR THE VARIOUS SUBSTRATES, AS INDICATED. .1 IMPERIAL CABINET CO., INC. THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE STRAIGHT WiTH NO DISTORTIONS. .2 MERILIAT INDUSTRIES, INC. INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL 6.10 JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM 1. FERROUS METAL: .3 YORKTOWNE CABINETS PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD. WIDTH NOT TO EXCEED 1/8 U.O.N. A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: 6.11 GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WiTH ELECTRICAL 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC 15/16 MECHANICAL AND ELECTRICAL DEMOLITION OUTLETS. LATEX PRIMER. 2. FINISH: 2 COATS 183XX MIRROLAC-WB ACRYLIC 15/16.1 MECHANICAL (INCLUDING PLUMBING, FIRE PROTECTION AND HVAC) AND COORDINATE DEMOLITION WiTH CONSTRUCTION PLANS TO DETERMINE SEMI -GLOSS ENAMEL ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE 7 JOINT SEALERS 2. NON-FERROUS METAL: RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW A ACRYLIC SEMI -GLOSS ENAMEL FINISH: ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC WORK. 7.1 ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR AND FIXTURES: LATEX PRIMER. BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT, .1 "DOW CORNING 786'; DOW CORNING CORP. 2, FINISH: 2 COATS #83XX MIRROLACE-W8 ACRYLIC INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION .2 "SCS 1702 SANITARY; GENERAL ELECTRIC CO. SEMI -GLOSS FINISH ELECTRICAL SYSTEMS. TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND .3 '863 1345 WHiTE"; PECORA CORP. 3. FERROUS STRUCTURE: 15/16.2 GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING .4 "PROGLAZE WHITE'; TREMCO CORP. A. ACRYLIC DRY FOG FLAT FINISH: DESIGN/BUILD DRAWINGS FOR ARE PROTECTION, MECHANICAL, AND ADJACENT SURFACES, INCLUDING WiTH REGARD TO MATERIALS AND .5 'OMNIPLUS'; SONNEBORN BUILDING PRODUCTS 1. FINISH: 2 COATS 157601 UNI -GRIP -WB WATER PLUMBING, SIGNED AND STAMPED FOR STATE RUNG PROCESS BY A WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED REDUCIBLE ACRYLIC DRY FOG COATING CERTIFIED ENGINEER. TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR 7.2 ACRYUC-EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING 4. NON-FERROUS STRUCTURE: 15/16.3 IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S ADDITIONAL WORK RELATED TO SUCH ACTMTiES. SURFACES: A ACRYLIC DRY FOG FLAT FINISH: DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED .1 "CHEM -CALX 600"; BOSTIK CONSTRUCTION PRODUCTS DIV. 1. FINISH: 2 COATS 15760T UNI -GRIP -WB WATER DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL .2 "AC -20'; PECORA CORP. REDUCIBLE ACRYUC DRY FOG COATING. AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL BE INCLUDED. .3 'SONOLAC"; SONNEBORN BUILDING PRODUCTS 8. WOOD: DRAWINGS SHALL GOVERN, NOTIFY ARCHITECT OF DISCREPANCIES AND REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE .4 "TREMCO ACRYLIC LATEX 834'; TREMCO, INC. A ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH: OBTAIN WRITTEN CLARIFlCATION PRIOR TO PROCEEDING WiTH WORK. DRAWINGS. 1. PRIMER: 1 COAT #51701 WONDER -PRIME LATEX 15/16.4 SUBMIT FIRE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE 8 DOORS AND WINDOWS PRIMER -SEALER. OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED 2. FINISH: 2 COATS 183XX MIRROLAC-WB ACRYLIC SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND 8.1 INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS SEMI -GLOSS ENAMEL COORDINATE WiTH OTHER CEILING COMPONENTS. METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WiTH NEW NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER. B. STAIN -VARNISH RUBBED FINISH: 15/16.5 DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS FINISHES. 8.2 INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED 1. FILLER: 1 COAT 14800 WONDER WOODSTAIN SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH. PASTE WOOD FILLER (OPEN GRAIN WOODS). OWNER'S AGENT, REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR 8.3 DOOR HARDWARE: BUILDING STANDARD WiTH ADA LEVER HANDLE LATCH 2. STAIN: 1 COAT f96XX WONDER WOODSTAIN 15/16.6 OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED NOTED TO BE REPAIRED. AND LOCKSETS. ALKYD STAIN. WiTH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED. SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS. 8.4 GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 3. SEALER: 1 COAT 14900 WONDER WOODSEALER VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS REQUIREMENTS FOR HEAT -STRENGTHENED GLASS. QUICK DRY SEALER. EQUIPMENT. REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK 4. FINISH: 2 COATS 14600 WONDER WOODSTAIN 15/16.7 SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE IN SCOPE OF CONTRACT. 9 FINISHES ALKYD SATIN VARNISH. GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING 10. GYPSUM WALLBOARD: 15/16.8 DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS 9.1 GYPSUM BOARD WALL FRAMING: COMPLY WiTH ASTM C645. A ACRYLIC LATEX SATIN ENAMEL FINISH: INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL ELEVATOR DOORWAYS, EXiT STAIR DOORWAYS, ETC. CARPET MATS 1. PRIMER: 1 COAT 150801 WONDER TONES LATEX COORDINATE AT THE BEGINNING OF THE PROJECT WiTH THE TENANT AND SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT .1 INSTALL "EUMINATOR' TYPE HEAD TRACK AT WALLS TERMINATING PRIMER -SEALER. TENANTS VENDORS TO DETERMINE THE PHASE DURING WHICH THE THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS, AT CEIUNG. USE PREFORMED OUTSIDE CORNERS. 2. FINISH: 2 COATS 135XX WONDER TONE ACRYUC INSTALLATION SHALL OCCUR. CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES LATEX SATIN ENAMEL 15/16.9 DIMENSIONS, IF IDENTIFIED, ARE TO CENTERUNE OF OUTLET OR GANG OF AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY 9.2 GYPSUM BOARD: PROVIDE 5/8' THICK REGULAR AND TYPE 'X' TAPERED 13. PRECAST CONCRETE: A. LATE( TEXTURE COATING -SAND FINISH (WET AREAS) OUTLETS, UNLESS OTHERWISE NOTED. SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE- EDGE GYPSUM BOARD WiTH GALVANIZED STEEL TRIM ACCESSORIES AND 15/16.10 ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED JOINT COMPOUND COMPLYING WiTH ASTM C475. FINISH IN ACCORDANCE 1. PRIMER: 1 COAT J1502 WONDER -SHIELD ACRYLIC COLOR UNLESS NOTED OTHERWISE, IF NO BUILDING STANDARD, PROVIDE CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR T1 WiTH ASTM C840 TO THE HIGHEST QUALITY STANDARDS. LATEX HOUSE PAINT PRIMER. IVORY. DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS 2. FINISH: 1 COAT #44101 DEV-VO-TEX LATEX 15/16.11 WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY PLUMBING, HVAC, ELECTRICAL, AND ARE PROTECTION SYSTEMS. .1 DRYWALL FINISHING: COMPLY WiTH MANUFACTURER'S PRINTED TEXTURE COATING. SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WiTH PROVIDING PROPER ACCESS TO RECEPTACLES. RECORD SEPIA TO SERVE AS PART OF THE "AS -BUILT' SET. MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA- 15/16.12 IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WiTH ARCHITECTURAL PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT, 216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND 9,11 WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, CLEAN AND FOR SPECIFIC LOCATION. SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE FINISHING OF GYPSUM BOARD. WITHOUT WRINKLES, GAPS OR OVERLAPS. 15/16.13 CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN. LOCATIONS ON SLAB AND PROVIDE ACCESS TO SiTE FOR ARCHITECT TO 9.4 CEILINGS: FINISHED CEILING SHALL BE LEVEL„ TRUE AND FREE FROM .1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT OBSERVE PRIOR TO ANY COMMENCEMENT OF "ROUGH -IN' METAL FABRICATIONS DAMAGED OR SOILED TILES. ACCEPTABLE. CONSTRUCTION. 2 SEAMS MUST BE AT LEAST 2' FROM INSIDE CORNERS AND 6' FROM PROVIDE STEEL FRAAND SUPPORTS FOR APPLICATIONS INDICATED 1 COORDINATE PLACEMENT OF MECHA1NICAL AND ELECTRICAL ITEMS OUTSIDE CORNERS. OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL GN GENERAL NOTES REQUIRED TO COMPLETE WORK. REFLECTED CEILING PLAN SHALL GOVERN. 10 SPECIALTIES .2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN GN.1 CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND WOOD AND PLASTIC UGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXiT SIGNS 10.1 ARE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO UNLESS NOTED OTHERWISE. BUILDING STANDARD, PROVIDE JL INDUSTRIES 'AMBASSADOR' SERIES, PROCEEDING WITH CONSTRUCTION. CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE "CONSTRUCTION SEMI RECESSED, DUO -PANEL, FIELD PAINTED. GN.2 DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: GRADE" LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE 9.5 INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERUNE OF DOOR OR CONTENT. CASED OPENING UNLESS NOTED OTHERWISE. A TO FINISHED FACE OF GYPSUM BOARD. PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS. EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA .1 INSTALL JOHNSONTTE TRIM STRIPS AT DOOR WHERE CARPET C. TO TOP OF FINISHED FLOORS. C -D PLUGGED INT WiTH EXTERIOR GLUE, NOT LESS THAN 15/32'. MEETS RESILIENT TILE WiTH TRiM STRiP COLOR TO MATCH D. TO BOTTOM OF FINISHED CEILINGS. FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND CARPET. PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WiTH AWPA GN.3 SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION, C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WiTH 9.6 RESILIENT FLOORING: EXISTING CONSTRUCTION AND WALL TYPES. CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING GNA TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED JURISDICTION. .1 UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS OTHERWISE. FINISH CARPENTRY AND MILLWORK: COMPLY WiTH 'PREMIUM GRADE' AWI ESTABLISHED WiTH PRINCIPAL WALLS, SO THAT TiLE AT GN.5 DO NOT SCALL: DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION STANDARDS. OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS AVOID USE OF CUT WIDTHS LESS THAN 3' AT ROOM PERIMETER. SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, .1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR .2 BASE: FIT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLD NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING TO FABRICATION OF MULTIPLE UNITS. BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING WiTH CONSTRUCTION. ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. GN.6 CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WiTH FOR THE ARCHITECT'S OBSERVATION WiTH REGARD TO DESIGN INTENT. NEMA LD 3 AND GP -50 (0.050" NOMINAL THICKNESS). 9.7 USE AN APPROVED CEMENTiTIOUS FILLER TO PATCH CRACKS, SMALL DO NOT PROCEED WiTH INSTALLATION OF STUDS WiTHOUT THIS HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WiTH MAXIMUM OBSERVATION. .1 EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL SURFACE VARIATION OF V IN 10 FEET, NON -CUMULATIVE. GNJ FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT SURFACES. LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT .2 PROVIDE 2' DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE RELEASED FOR CO -'.;'SW', W dOT VARY BY MORE THAN 1/4" IN 20'-0' NON- ELECTRICAL OR DATA OUTLET LOCATIONS. 9.8 CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING '�1 MYsDESIGNER IF TOLERANCE IS EXCEEDED. Subject to com ' "I ��ith JAR '' ' R SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO STANDARDS: �C�erT Ot Stat,-, r? i Loc -,v C _WNS CABINETS: COMPLY WiTH AWI SECTION 400 AND iiS DIVISION 4008 FOR DEPT „-NOF;PREMIUM OF CQMMUNIT I RE RATED GRADE NEMA LD3 LAMINATE CLAD CABINETS. FLAMMABILITY: ASTM 2859 PARTITIONING SFWl BE CAULKED AT SURFACE BURNING: ASTM E84 CITY OF CARMEL % CL#d�M-MCAL OR ARE RATED SEALANT AS APPLICABLE. .1 EXPOSED SURFACES: HORIZONTAL SUR7ACES OTHER THAN TOPS: SMOKE DENSITY: ASTM E662 --- INDIp jC PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. GP -50 (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP -28 SOUND ABSORPTION: ASTM C423 ROVIDE WiTH SOUND ATTENUATING INSULATION SECURELY FASTENED (0.028" NOMINAL THICKNESS); EDGES: GP -28 (0.028' NOMINAL FADE RESISTANCE: AATCC 16E TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL THICKNESS). STATIC RESISTANCE: AATCC 134 JUNCTION BOXES ARE NOT PERMITTED. .2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28. WARRANTY: 10 YEARS GNAO All APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY .3 CABINET HARDWARE SCHEDULE: CONTRACTOR, .1 INSTALL BROADLOOM CARPET BY DIRECT GLUE. .1 HINGES: FULLY CONCEALED, SELF-CLOSING '1000 SERIES' BY GRASS OR EQUAL .2 PULLS: AIRE PROJECTING TYPE, DRILLING 4' ON CENTER, 14483 OR EQUAL AS MANUFACTURED BY STANLEY. CITY OF CARNIEL/CLAY TOWNSHIP .3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH Dept. of Community Services -- Building &Code Enforcement MINIMUM 8 LBS. PULL; SP 45 OR SP 46 OR EQUAL AS One Civic Square 1' Floor; Carmel, IN 46032 MANUFACTURED BY STANLEY. CERTIFICATIONS AND AGREEMENT .4 DRAWER GUIDES: SIDE AND BOTTOM MOUNTED SLIDES PLAN AUTHENTICATION WITH POSITIVE STOP AND LOCKOUT POSITION, WITIi As the authorized agent responsible for obtaining a permit or permits', I certify that these plans Indiana Dept. of Fire & Building HEAVY-DUTY FULL EXTENSION; 1429 OR EQUAL AS are IDENTICAL to those released for construction by the these are not identical, a STOP MANUFACTURED BY KNAPE & VOGT. Services. I also understand that if it is determined that plans the Ordinances referenced below. .5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF WORK DRDER will be served, as required under SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION c , .� '_ ! 1 �'�- - ' y,, �'J MOLDED NYLON AND WiTH HEAVY DUTY TWIN SLOTTED Authorized Signature Printed Name SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT OR EQUAL 'Required under Chapter 7, Section 10 of the Carmel City Code, entitled "Building Code" and Section 29.4.2 Township Zoning Ordinance, Section and Section 29.4 .3 entitled "Administration". Required by Carmel / Clay "violations and Penalties". 014 31.1 entitled Date S:Permits /Forms'AuthentStickerl 1-01 [I= :3 0 Z 0 LL U 000 L 000L L 2 000 `6laq`ot4910EtfSaAp`� ���v Q�P�G1S I fq�� •'`� �.9n No. = ARCC9IO036 STATE OF sr %. /A 08/0 /0 CSO #23126