Loading...
HomeMy WebLinkAbout03100045.21n' -H" 35-41„ STRUCTURAL DECK CEILING CONT. ACOUS. SEALANT BOTH SIDES, TYP. WHEN INSULATED 0 z 00 ONE LAYER 5/8" G.W.B. 3 5/8" MTL STUDS AT 16" O.C. CONT. 2 1/2" SOUND ATTENUATION INSUL.- FULL HGT. WALL WHEN INDICATED BY WALL TYPE MODIFIER CONT. ACOUS. SEALANT BOTH SIDES. TYP. WHEN INSULATED 8 1_a C Ab NO SOUND ATTENUATION INSULATION IDPROVIDE LEAD FACED GYPSUM BOARD ON G.W.B. FACING X-RAY ROOM 1Ad PARTITION TO UNDERSIDE OF BULKHEAD FLOOR PLAN A201 1/4" = 1'-O" __1 (;D NORTH CONT. ACOUS. SEALANT BOTH SIDES, TYP. ONE LAYER 5/8" G.W.B. 6" MTL. STUDS AT 16" O.C. CONT, 2 1/2" SOUND ATTENUATION INSUL.- FULL HGT. WALL WHEN INDICATED BY WALL TYPE MODIFIER CONT. ACOUS. SEALANT BOTH SIDES, TYP. WHEN INSULATED CONT. ACOUS. SEALANT BOTH SIDES, TYP. 0 z SKIM COAT PLASTER 'LEVEL 5' WALL FINISH, BOTH SIDES TWO LAYERS 1/2" G.W.B. EACH SIDE TWO 3 5/8" MTL. STUDS AT 16" O.C. CONT. 2 1/2" SOUND ATTENUATION INSUL.- FULL HGT. WALL WHEN INDICATED BY WALL TYPE MODIFIER PAINTED HARDWOOD BASE REF. DETAIL 9/A-804 — CONT. ACOUS. SEALANT BOTH SIDES, TYP. �- STANDARD 'LEVEL 4' DRYWALL FINISH iD SIDE FACING LAB A211 SKIM COAT PLASTER 'LEVEL 5' DRYWALL FINISH, SIDE FACING OPERATORY A210 ONLY TWO LAYERS 1/2" G.W.B. TWO 3 5/8" MTL, STUDS AT 16" O.C. CONT. 2 112- SOUND ATTENUATION INSUL.- FULL HGT. WALL WHEN INDICATED BY WALL TYPE MODIFIER PAINTED HARDWOOD BASE FACING OPERATORY A210 ONLY REF. DETAIL 9/A-804 SCHEDULED RESILIENT BASE CONT. ACOUS. SEALANT BOTH SIDES, TYP. 0 z 00 ONE LAYER 5/8" G.W.B. TWO LAYERS 1/2" G.W.B. ON SIDE FACING OPERATORY A210 ONLY BOTTOM OF DECK — — — — — — — — — CEILING (n:) i 5/8" MTL, STUDS AT 16" O.C. :ONT. 2 1/2" SOUND ATTENUATION 4SUL.- FULL HGT, WALL WHEN VDICATED BY WALL TYPE MODIFIER SCHEDULED RESILIENT BASE PAINTED HARDWOOD BASE, SIDE FACING OPERATORY A210 ONLY REF. DETAIL 9/A-804 74" 94" NOTE: REFER TO ELEVATIONS 3/A-401 AND 4/A-401 FOR LOCATIONS OF 1/2" 94" NOTE: REFER TO ELEVATIONS 3/A-401 AND 4/A-401 FOR LOCATIONS OF 1/2" 8 NOTE: REFER TO ELEVATIONS 3/A-401 AND - I� 13590 B North Meridian St. ,�- Carmel, Indiana 46032 I , on Owner 4/A-401 FOR LOCATIONS OF 1/2 2_a 3_a DRYWALL REVEALS ON WALLS FACING OPERATORY A210 4_a DRYWALL REVEALS ON WALLS FACING OPERATORY A210 5-o DRYWALL REVEALS ON WALLS FACING OPERATORY A210 PARTITION GENERAL NOTES ( PROVIDE WATER RESISTANT GWB IN ALL ROOMS CONTAINING OPERABLE PLUMBING FIXTURES AND WITHIN 4 FEET OF DRINKING FOUNTAINS / WATER COOLERS, U.N.O. (2) PROVIDE LATERAL BRACING FOR PARTITIONS WHICH EXTEND ABOVE CEILING PARTITION- PARTITION TYPES O OTHIERWISE CAL NOTED WTHLLPARTITION SYMBOL:NLESS X-000 1/2" = 1'-0" (E)— PARTITION SYMBOL LEGEND OPTIONAL ATTRIBUTE FOR FIRE RATING, HEIGHT, ETC. XHR Xx GENERAL WALL CONFIGURATION 1-99 WALL TOP CONDITION A,B WALL DESIGN MODIFIER o z 3/4" THICK X 5-1/4" PAINTED WOOD CAP, PAINT TO MATCH WINDOW TRIM - ONE LAYER 5/8" G.W.B. 3-5/8" MTL. STUDS @ 16" O.C. 3-1/2" X 3-1/2" X 1/4" STEEL ANGLE ® EVERY OTHER STUD. 3-1/2" X 3-1/2" X 1/4" STEEL ANGLE SCHEDULED RESILIENT BASE 8� ANCHOR DIRECTLY TO SUBFLOOR W FINISHED FLOOR GENERAL NOTES: 1. THESE GENERAL NOTES APPLY TO ALL ARCHITECTURAL DRAWINGS. 2. ALL WORK SHOWN ON THE DRAWINGS SHALL BE BASE BID UNLESS SPECIFICALLY NOTED TO BE BY ALTERNATE BID. 3. FIELD VERIFY EXISTING FINISH FLOOR ELEVATIONS PRIOR TO STARTING CONSTRUCTION. MATCH NEW FLOOR ELEVATIONS WITH EXISTING UNLESS NOTED OTHERWISE, 4. DIMENSIONS TO ARE TO FINISH SURFACE, UNLESS OTHERWISE NOTED. FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO STARTING WORK AND NOTIFY ARCHITECT IMMEDIATELY IF DISCREPANCIES ARE FOUND BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS, 5. DO NOT SCALE DRAWINGS. REFER DIMENSION QUESTIONS TO ARCHITECT FOR INTERPRETATION. 6. DOOR AND FRAME NUMBERS CORRESPOND TO RESPECTIVE ROOM NUMBERS, IN ROOMS WITH MULTIPLE OPENINGS, A SUFFIX HAS BEEN ADDED TO DOOR NUMBERS, I.E., A201 -A. 7. LOCATE INSIDE FACE OF DOORFRAME JAMBS 6 INCHES FROM FINISH FACE OF ADJACENT WALLS UNLESS NOTED OTHERWISE. 8. COORDINATE EQUIPMENT WORK WITH MANUFACTURERS AND SUPPLIERS TO ENSURE PROPER ROUGH -IN CLEARANCES FOR INSTALLATION, USE AND MAINTENANCE, 9. PROTECT EXISTING SURFACES TO REMAIN THAT ARE NOT INCLUDED IN SCOPE OF WORK BUT THAT ARE WITHIN AREAS OF CONSTRUCTION ACTIVITY, 10, PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD WALL CONSTRUCTION AS INDICATED. WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0." VERIFY FINAL CONTROL JOINT LOCATIONS WHETHER OR NOT INDICATED ON THE DRAWINGS WITH ARCHITECT PRIOR TO STARTING WORK 11. WOOD OR METAL STUD SPACING SHALL BE 16" ON CENTER UNLESS NOTED OTHERWISE. 12. PROVIDE WATER-RESISTANT GYPSUM BOARD ON WALLS WITH OPERABLE PLUMBIP!G FIXTURES AND WITHIN 4'-0" OF DRINKING FOUNTAINS OR WATER COOLERS. 13. PROVIDE FINISHED END PANELS, FILLERS, SUPPORTS, ETC. REQUIRED FOR A COMPLETE CABINETRY INSTALLATION. PROVIDE CUTOUTS, ACCESS PANELS AND REMOVABLE COMPONENTS AS REQUIRED BY NEW OR EXISTING CONDITIONS SUCH AS ELECTRICAL OUTLETS, JUNCTION BOXES, CLEANOUTS, ETC. MOUNT TOP OF WALL CABINETS AT +7'-2" A.F.F. UNLESS NOTED OTHERWISE. 14. VERIFY MOUNTING HEIGHTS OF ACCESSORIES, EQUIPMENT, DOOR HARDWARE, CASEWORK, ETC., AND PROVIDE SOLID BLOCKING BEHIND ITEMS REQUIRING ANCHORAGE. PROVIDE FIRE -TREATED WOOD BLOCKING OR METAL STRAPS BETWEEN FRAMING MEMBERS AS REQUIRED TO SUPPORT WEIGHT AND USE OF ITEMS TO BE SUPPORTED. WHERE MOUNTING HEIGHTS ARE NOT INDICATED, MOUNT ITEMS AT RECOGNIZED INDUSTRY STANDARD MOUNTING HEIGHTS, COORDINATE LOCATIONS WITH MANUFACTURER OR SUPPLIER AND REFER ANY MOUNTING HEIGHT QUESTIONS TO ARCHITECT FOR INTERPRETATION, 15. PROVIDE SEALANT BETWEEN HOLLOW METAL FRAME PERIMETERS AND SURROUNDING WALL CONSTRUCTION UNLESS NOTED OTHERWISE. 16. PROVIDE SEALANT BETWEEN INTERIOR AND EXTERIOR WINDOW AND STOREFRONT FRAME PERIMETERS AND SURROUNDING CONSTRUCTION UNLESS NOTED OTHERWISE, 17. PROVIDE SEALANT BETWEEN DISSIMILAR MATERIALS SUCH AS GYPSUM BOARD AND MASONRY, MASONRY AND CONCRETE, COUNTERTOPS AND WALLS, ETC. 18. THESE NOTES ARE ONLY APPLICABLE TO THIS BID PACKAGE AND MAY NOT BE APPLICABLE TO FUTURE BID PACKAGES. SOME WORK WHICH WAS INCLUDED IN PREVIOUS BID PACKAGES OR WILL BE INCLUDED IN FUTURE BID PACKAGES IS SHOWN ON THESE CONSTRUCTION DOCUMENTS FOR REFERENCE PURPOSES ONLY AND IS IDENTIFIED AS SUCH. WATERPROOFING AND BACKFILLING AGAINST FOUNDATION WALLS CONSTRUCTED AS PART OF PREVIOUS BID PACKAGES SHALL BE INCLUDED AS PART OF THIS WORK. 19. DO NOT BEGIN ANY WORK THAT MAY REQUIRE COORDINATION SUCH AS CEILING INSTALLATION PRIOR TO FINAL SUBMITTAL OF MECHANICAL AND ELECTRICAL COORDINATION DRAWINGS TO ARCHITECT NOR PRIOR TO RESOLUTION AND APPROVAL OF ALL COORDINATION ISSUES. 20. REFER TO SERIES 200 DRAWINGS FOR PARTITION CONSTRUCTION TYPE. 21. ON FLOOR PLAN A-201, IN ADDITION TO PARTITION TAGS, WALLS TO UNDERSIDE OF DECK ARE DESIGNATED WITH THE FOLLOWING HATCH PATTERN: FLOOR PLAN KEY NOTES (KEYED ON THE PLANS) OACOUSTICAL WALLCOVERING 'AWC1' FROM TOP OF BACK SPLASH TO UNDERSIDE OF WALL CABINETS. OULTRASONIC CLEANER EQUIPMENT BY OWNER. CONTRACTOR SHALL COORDINATE COUNTERTOP OPENING TO ACCOMODATE EQUIPMENT. OADJUSTABLE SHELVING, 8 SHELVES, 3/4" THICK SUBSTRATE, PLASTIC LAMINATE 'PL4' CLAD, V-0" DEEP, ON ADJUSTABLE KV BRACKETS AND STANDARDS. SPACE SUPPORTS EVERY 3'-0". O1/2" PLYWOOD SHEETS FROM TOP OF WALL BASE TO UNDERSIDE OF CEILING, TO ACCOMODATE PHONE BOARD AND VARIOUS MOUNTED ELECTRICAL EQUIPMENT. PAINT PLYWOOD TO MATCH WALLS. O5 COMPRESSOR EQUIPMENT BY OWNER, OUNDERCOUNTER DISHWASHER SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR. O7 REFRIGERATOR SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR, OWALL MOUNTED MOP SINK, OBUBBLERS RELOCATED FROM OWNER'S EXISTING FACILITY. CONTRACTOR SHALL INSTALL AND COORDINATE WITH NEW CASEWORK. 10 RECESSED LIGHT TABLE RELOCATED FROM OWNER'S EXISTING FACILITY. CONTRACTOR SHALL COORDINATE WITH CASEWORK. 11 NEW RECESSED LIGHT TABLE BY OWNER, CONTRACTOR SHALL COORDINATE WITH CASEWORK, 12 CUSTOM CASEWORK, REF. ELEVATIONS. 13 CUSTOM CASEWORK LOCKERS, REF. ELEVATION, 14 X-RAY EQUIPMENT SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR. COORDINATE W/ OWNER ANY REQ'D BLOCKING IN WALLS FOR ANY WALL MOUNTED X-RAY EQUIPMENT, 15 CEPH. EQUIPMENT SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR. COORDINATE W/ OWNER ANY REQ'D BLOCKING IN WALLS. 16 EXAM CHAIR SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR. 17 SERVICE UNIT SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR. 18 PUBLIC TOILET ROOMS NOT IN SCOPE OF TENANT BUILD OUT. 19 ALIGN FINISH FACE OF PARTITION WITH EDGE OF WINDOW FRAME. 20 ALIGN FINISH FACE OF TENANT PARTITION WITH FINISH FACE OF BUILDING DE CORE DEMISING PARTITION. 21 DIMENSION IS FROM OUTSIDE EDGE OF WINDOW FRAME TO FINISH FACE OF PARTITION, 22 FINISH FACE OF ARC WALL TERMINATES AT OUTSIDE EDGE OF WINDOW FRAME. 23 ALIGN FACE OF ARC WALL AS IF IT TERMINATES AT INSIDE CORNER OF INTERSECTING WALLS AS SHOWN. 24 FLATSCREEN MONITOR BY OWNER ON FRONT FACE OF BULKHEAD ABOVE. 25 COAT ROD & SHELF, REF. DETAIL 7/A-804. I O.H. Rigsbee, III, D.D.S., M.S. Specialist in Orthodontics I� 13590 B North Meridian St. Carmel, Indiana 46032 I I I Owner FCC Development 6214 Northwood Dr. Carmel, Indiana 46032 tel 317.846-5800 Architect / Interior Designer RATIO Architects, Inc. RATIO 1 Suite 100, Schrader Building ') 107 South Pennsylvania Street � �I 1 Indianapolis, Indiana 46204-3684 tel 317.633.4040 fax 317.633.4153 AItHITEtis I Mechanical, Electrical, Plumbing Engineers r Biagi, Chance, Cummins, London Titzer, Inc. 300 N.W. Second Street Evansville, Indiana 47708 tel 812 423 4407 I i 1 f I I I I I � I I i f DRAWN BY r ! SRH BR I\\\`\\\\0\\`',�Illll{IIfl11l//p/��U,'r/,i f��\P ir� fk G % E9F•• v: • �.t�` CHECKED BY Q` No. _: _ 4154 STATE OF •. P •; ` APPROVED BY �''% .9�Npl•AN'• ����`�� � ,,'/','' //► lulu �G �\\\\� �I i RATIO COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONRDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO ARCHITECTS, INC. NO OTHER USE, =���� DISSEMINATION OR DUPLICATION MAY BE MADE WTHOUT PRIOR WRITTEN CONSENT OF RATIO ARCHITECTS, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND ARCHITECTS OTHERWISE ARE HEREBY SPEgFlCALLY RESERVED. REVISIONS !0 10 0 0 D 0 I i SHEET TITLE FLOOR PLAN PROJECT NO. SHEET NUMBER 03025.00 DATE A-201 AUGUST 2003