HomeMy WebLinkAbout03100045.21n' -H" 35-41„
STRUCTURAL
DECK
CEILING
CONT. ACOUS. SEALANT BOTH
SIDES, TYP. WHEN INSULATED
0
z
00
ONE LAYER 5/8" G.W.B.
3 5/8" MTL STUDS AT 16" O.C.
CONT. 2 1/2" SOUND ATTENUATION
INSUL.- FULL HGT. WALL WHEN
INDICATED BY WALL TYPE MODIFIER
CONT. ACOUS. SEALANT BOTH
SIDES. TYP. WHEN INSULATED
8
1_a
C Ab NO SOUND ATTENUATION
INSULATION
IDPROVIDE LEAD FACED
GYPSUM BOARD ON
G.W.B. FACING X-RAY
ROOM
1Ad PARTITION TO UNDERSIDE
OF BULKHEAD
FLOOR PLAN
A201 1/4" = 1'-O"
__1 (;D
NORTH
CONT. ACOUS. SEALANT BOTH
SIDES, TYP.
ONE LAYER 5/8" G.W.B.
6" MTL. STUDS AT 16" O.C.
CONT, 2 1/2" SOUND ATTENUATION
INSUL.- FULL HGT. WALL WHEN
INDICATED BY WALL TYPE MODIFIER
CONT. ACOUS. SEALANT BOTH
SIDES, TYP. WHEN INSULATED
CONT. ACOUS. SEALANT BOTH
SIDES, TYP.
0
z
SKIM COAT PLASTER 'LEVEL 5'
WALL FINISH, BOTH SIDES
TWO LAYERS 1/2" G.W.B.
EACH SIDE
TWO 3 5/8" MTL. STUDS AT 16" O.C.
CONT. 2 1/2" SOUND ATTENUATION
INSUL.- FULL HGT. WALL WHEN
INDICATED BY WALL TYPE MODIFIER
PAINTED HARDWOOD BASE
REF. DETAIL 9/A-804
— CONT. ACOUS. SEALANT BOTH
SIDES, TYP.
�- STANDARD 'LEVEL 4' DRYWALL FINISH
iD SIDE FACING LAB A211
SKIM COAT PLASTER 'LEVEL 5'
DRYWALL FINISH, SIDE FACING
OPERATORY A210 ONLY
TWO LAYERS 1/2" G.W.B.
TWO 3 5/8" MTL, STUDS AT 16" O.C.
CONT. 2 112- SOUND ATTENUATION
INSUL.- FULL HGT. WALL WHEN
INDICATED BY WALL TYPE MODIFIER
PAINTED HARDWOOD BASE
FACING OPERATORY A210 ONLY
REF. DETAIL 9/A-804
SCHEDULED RESILIENT BASE
CONT. ACOUS. SEALANT BOTH
SIDES, TYP.
0
z
00
ONE LAYER 5/8" G.W.B.
TWO LAYERS 1/2" G.W.B. ON SIDE
FACING OPERATORY A210 ONLY
BOTTOM OF DECK
— — — — — — — — — CEILING (n:)
i 5/8" MTL, STUDS AT 16" O.C.
:ONT. 2 1/2" SOUND ATTENUATION
4SUL.- FULL HGT, WALL WHEN
VDICATED BY WALL TYPE MODIFIER
SCHEDULED RESILIENT BASE
PAINTED HARDWOOD BASE, SIDE
FACING OPERATORY A210 ONLY
REF. DETAIL 9/A-804
74"
94"
NOTE: REFER TO ELEVATIONS 3/A-401
AND 4/A-401 FOR LOCATIONS OF 1/2"
94"
NOTE: REFER TO ELEVATIONS 3/A-401
AND 4/A-401 FOR LOCATIONS OF 1/2"
8
NOTE: REFER TO ELEVATIONS 3/A-401
AND -
I�
13590 B North Meridian St.
,�-
Carmel, Indiana 46032
I
, on
Owner
4/A-401 FOR LOCATIONS OF 1/2
2_a
3_a
DRYWALL REVEALS ON WALLS FACING
OPERATORY A210
4_a
DRYWALL REVEALS ON WALLS FACING
OPERATORY A210
5-o
DRYWALL REVEALS ON WALLS FACING
OPERATORY A210
PARTITION GENERAL NOTES
( PROVIDE WATER RESISTANT GWB IN ALL ROOMS CONTAINING
OPERABLE PLUMBING FIXTURES AND WITHIN 4 FEET OF
DRINKING FOUNTAINS / WATER COOLERS, U.N.O.
(2) PROVIDE LATERAL BRACING FOR PARTITIONS
WHICH EXTEND ABOVE CEILING
PARTITION- PARTITION TYPES O OTHIERWISE CAL NOTED WTHLLPARTITION SYMBOL:NLESS
X-000 1/2" = 1'-0" (E)—
PARTITION SYMBOL LEGEND
OPTIONAL ATTRIBUTE FOR
FIRE RATING, HEIGHT, ETC. XHR
Xx
GENERAL WALL CONFIGURATION 1-99
WALL TOP CONDITION A,B
WALL DESIGN MODIFIER o z
3/4" THICK X 5-1/4" PAINTED WOOD CAP,
PAINT TO MATCH WINDOW TRIM
- ONE LAYER 5/8" G.W.B.
3-5/8" MTL. STUDS @ 16" O.C.
3-1/2" X 3-1/2" X 1/4" STEEL ANGLE
® EVERY OTHER STUD.
3-1/2" X 3-1/2" X 1/4" STEEL ANGLE
SCHEDULED RESILIENT BASE
8� ANCHOR DIRECTLY TO SUBFLOOR
W
FINISHED
FLOOR
GENERAL NOTES:
1. THESE GENERAL NOTES APPLY TO ALL ARCHITECTURAL DRAWINGS.
2. ALL WORK SHOWN ON THE DRAWINGS SHALL BE BASE BID UNLESS SPECIFICALLY NOTED
TO BE BY ALTERNATE BID.
3. FIELD VERIFY EXISTING FINISH FLOOR ELEVATIONS PRIOR TO
STARTING CONSTRUCTION. MATCH NEW FLOOR ELEVATIONS WITH EXISTING UNLESS
NOTED OTHERWISE,
4. DIMENSIONS TO ARE TO FINISH SURFACE, UNLESS OTHERWISE NOTED. FIELD
VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO STARTING WORK AND NOTIFY
ARCHITECT IMMEDIATELY IF DISCREPANCIES ARE FOUND BETWEEN CONTRACT DOCUMENTS
AND ACTUAL FIELD CONDITIONS,
5. DO NOT SCALE DRAWINGS. REFER DIMENSION QUESTIONS TO ARCHITECT FOR
INTERPRETATION.
6. DOOR AND FRAME NUMBERS CORRESPOND TO RESPECTIVE ROOM NUMBERS, IN ROOMS
WITH MULTIPLE OPENINGS, A SUFFIX HAS BEEN ADDED TO DOOR NUMBERS, I.E., A201 -A.
7. LOCATE INSIDE FACE OF DOORFRAME JAMBS 6 INCHES FROM FINISH FACE OF
ADJACENT WALLS UNLESS NOTED OTHERWISE.
8. COORDINATE EQUIPMENT WORK WITH MANUFACTURERS AND SUPPLIERS TO ENSURE
PROPER ROUGH -IN CLEARANCES FOR INSTALLATION, USE AND MAINTENANCE,
9. PROTECT EXISTING SURFACES TO REMAIN THAT ARE NOT INCLUDED IN SCOPE OF
WORK BUT THAT ARE WITHIN AREAS OF CONSTRUCTION ACTIVITY,
10, PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD WALL CONSTRUCTION AS
INDICATED. WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0."
VERIFY FINAL CONTROL JOINT LOCATIONS WHETHER OR NOT INDICATED ON THE DRAWINGS
WITH ARCHITECT PRIOR TO STARTING WORK
11. WOOD OR METAL STUD SPACING SHALL BE 16" ON CENTER UNLESS NOTED OTHERWISE.
12. PROVIDE WATER-RESISTANT GYPSUM BOARD ON WALLS WITH OPERABLE PLUMBIP!G
FIXTURES AND WITHIN 4'-0" OF DRINKING FOUNTAINS OR WATER COOLERS.
13. PROVIDE FINISHED END PANELS, FILLERS, SUPPORTS, ETC. REQUIRED FOR A
COMPLETE CABINETRY INSTALLATION. PROVIDE CUTOUTS, ACCESS PANELS AND REMOVABLE
COMPONENTS AS REQUIRED BY NEW OR EXISTING CONDITIONS SUCH AS ELECTRICAL
OUTLETS, JUNCTION BOXES, CLEANOUTS, ETC. MOUNT TOP OF WALL CABINETS AT +7'-2"
A.F.F. UNLESS NOTED OTHERWISE.
14. VERIFY MOUNTING HEIGHTS OF ACCESSORIES, EQUIPMENT, DOOR HARDWARE, CASEWORK,
ETC., AND PROVIDE SOLID BLOCKING BEHIND ITEMS REQUIRING ANCHORAGE. PROVIDE
FIRE -TREATED WOOD BLOCKING OR METAL STRAPS BETWEEN FRAMING MEMBERS AS REQUIRED
TO SUPPORT WEIGHT AND USE OF ITEMS TO BE SUPPORTED. WHERE MOUNTING HEIGHTS
ARE NOT INDICATED, MOUNT ITEMS AT RECOGNIZED INDUSTRY STANDARD MOUNTING
HEIGHTS, COORDINATE LOCATIONS WITH MANUFACTURER OR SUPPLIER AND REFER ANY
MOUNTING HEIGHT QUESTIONS TO ARCHITECT FOR INTERPRETATION,
15. PROVIDE SEALANT BETWEEN HOLLOW METAL FRAME PERIMETERS AND SURROUNDING WALL
CONSTRUCTION UNLESS NOTED OTHERWISE.
16. PROVIDE SEALANT BETWEEN INTERIOR AND EXTERIOR WINDOW AND STOREFRONT FRAME
PERIMETERS AND SURROUNDING CONSTRUCTION UNLESS NOTED OTHERWISE,
17. PROVIDE SEALANT BETWEEN DISSIMILAR MATERIALS SUCH AS GYPSUM BOARD AND
MASONRY, MASONRY AND CONCRETE, COUNTERTOPS AND WALLS, ETC.
18. THESE NOTES ARE ONLY APPLICABLE TO THIS BID PACKAGE AND MAY NOT BE
APPLICABLE TO FUTURE BID PACKAGES. SOME WORK WHICH WAS INCLUDED IN PREVIOUS
BID PACKAGES OR WILL BE INCLUDED IN FUTURE BID PACKAGES IS SHOWN ON THESE
CONSTRUCTION DOCUMENTS FOR REFERENCE PURPOSES ONLY AND IS IDENTIFIED AS SUCH.
WATERPROOFING AND BACKFILLING AGAINST FOUNDATION WALLS CONSTRUCTED AS PART OF
PREVIOUS BID PACKAGES SHALL BE INCLUDED AS PART OF THIS WORK.
19. DO NOT BEGIN ANY WORK THAT MAY REQUIRE COORDINATION SUCH AS CEILING
INSTALLATION PRIOR TO FINAL SUBMITTAL OF MECHANICAL AND ELECTRICAL COORDINATION
DRAWINGS TO ARCHITECT NOR PRIOR TO RESOLUTION AND APPROVAL OF ALL COORDINATION
ISSUES.
20. REFER TO SERIES 200 DRAWINGS FOR PARTITION CONSTRUCTION TYPE.
21. ON FLOOR PLAN A-201, IN ADDITION TO PARTITION TAGS, WALLS TO UNDERSIDE OF
DECK ARE DESIGNATED WITH THE FOLLOWING HATCH PATTERN:
FLOOR PLAN KEY NOTES (KEYED ON THE PLANS)
OACOUSTICAL WALLCOVERING 'AWC1' FROM TOP OF BACK SPLASH TO UNDERSIDE OF
WALL CABINETS.
OULTRASONIC CLEANER EQUIPMENT BY OWNER. CONTRACTOR SHALL COORDINATE
COUNTERTOP OPENING TO ACCOMODATE EQUIPMENT.
OADJUSTABLE SHELVING, 8 SHELVES, 3/4" THICK SUBSTRATE, PLASTIC LAMINATE
'PL4' CLAD, V-0" DEEP, ON ADJUSTABLE KV BRACKETS AND STANDARDS. SPACE
SUPPORTS EVERY 3'-0".
O1/2" PLYWOOD SHEETS FROM TOP OF WALL BASE TO UNDERSIDE OF CEILING, TO
ACCOMODATE PHONE BOARD AND VARIOUS MOUNTED ELECTRICAL EQUIPMENT. PAINT
PLYWOOD TO MATCH WALLS.
O5 COMPRESSOR EQUIPMENT BY OWNER,
OUNDERCOUNTER DISHWASHER SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR.
O7 REFRIGERATOR SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR,
OWALL MOUNTED MOP SINK,
OBUBBLERS RELOCATED FROM OWNER'S EXISTING FACILITY. CONTRACTOR SHALL
INSTALL AND COORDINATE WITH NEW CASEWORK.
10 RECESSED LIGHT TABLE RELOCATED FROM OWNER'S EXISTING FACILITY.
CONTRACTOR SHALL COORDINATE WITH CASEWORK.
11 NEW RECESSED LIGHT TABLE BY OWNER, CONTRACTOR SHALL COORDINATE WITH
CASEWORK,
12 CUSTOM CASEWORK, REF. ELEVATIONS.
13 CUSTOM CASEWORK LOCKERS, REF. ELEVATION,
14 X-RAY EQUIPMENT SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR.
COORDINATE W/ OWNER ANY REQ'D BLOCKING IN WALLS FOR ANY WALL
MOUNTED X-RAY EQUIPMENT,
15 CEPH. EQUIPMENT SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR.
COORDINATE W/ OWNER ANY REQ'D BLOCKING IN WALLS.
16 EXAM CHAIR SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR.
17 SERVICE UNIT SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR.
18 PUBLIC TOILET ROOMS NOT IN SCOPE OF TENANT BUILD OUT.
19 ALIGN FINISH FACE OF PARTITION WITH EDGE OF WINDOW FRAME.
20 ALIGN FINISH FACE OF TENANT PARTITION WITH FINISH FACE OF BUILDING
DE
CORE DEMISING PARTITION.
21 DIMENSION IS FROM OUTSIDE EDGE OF WINDOW FRAME TO FINISH FACE OF
PARTITION,
22 FINISH FACE OF ARC WALL TERMINATES AT OUTSIDE EDGE OF WINDOW FRAME.
23 ALIGN FACE OF ARC WALL AS IF IT TERMINATES AT INSIDE CORNER OF
INTERSECTING WALLS AS SHOWN.
24 FLATSCREEN MONITOR BY OWNER ON FRONT FACE OF BULKHEAD ABOVE.
25 COAT ROD & SHELF, REF. DETAIL 7/A-804.
I O.H. Rigsbee, III, D.D.S., M.S.
Specialist in Orthodontics
I�
13590 B North Meridian St.
Carmel, Indiana 46032
I
I
I
Owner
FCC Development
6214 Northwood Dr.
Carmel, Indiana 46032
tel 317.846-5800
Architect / Interior Designer
RATIO Architects, Inc. RATIO
1 Suite 100, Schrader Building
')
107 South Pennsylvania Street � �I
1 Indianapolis, Indiana 46204-3684
tel 317.633.4040 fax 317.633.4153 AItHITEtis
I
Mechanical, Electrical, Plumbing Engineers r
Biagi, Chance, Cummins, London Titzer, Inc.
300 N.W. Second Street
Evansville, Indiana 47708
tel 812 423 4407
I
i
1
f
I
I
I
I
I
� I
I
i
f
DRAWN BY
r
! SRH BR I\\\`\\\\0\\`',�Illll{IIfl11l//p/��U,'r/,i
f��\P ir�
fk
G %
E9F••
v: • �.t�`
CHECKED BY Q` No.
_:
_ 4154
STATE OF
•. P •; `
APPROVED BY �''% .9�Npl•AN'• ����`��
�
,,'/',''
//► lulu �G �\\\\�
�I
i
RATIO COPYRIGHT NOTICE: THIS ARCHITECTURAL AND
ENGINEERING DRAWING IS GIVEN IN CONRDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT
WITH RATIO ARCHITECTS, INC. NO OTHER USE,
=���� DISSEMINATION OR DUPLICATION MAY BE MADE WTHOUT
PRIOR WRITTEN CONSENT OF RATIO ARCHITECTS, INC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND
ARCHITECTS OTHERWISE ARE HEREBY SPEgFlCALLY RESERVED.
REVISIONS
!0
10
0 0
D 0
I
i
SHEET TITLE
FLOOR PLAN
PROJECT NO. SHEET NUMBER
03025.00
DATE A-201