Loading...
HomeMy WebLinkAboutSoil and Water 05/01/91 15: 33 T317 776 1101 Haft. CO. WI) Q3003 • D FAMTLTON COUNTY SOIL AND WA t. CONSE'RVAT10N 317773-1406 CT 926 Division Street - Noblesville FAX 776-1101 46060 - (317) 1 , 1991 To: Ricin Br andaix, riasi5tant Director Department of Community Development Civic Square Carmel, Indiana 46032 From: John B. South, SWCD Engineer dq Tom Schellenberger, District Conservationist Project: Waterstone Primary I have reviewed the submitted plans and have the following comments. D DETAIL SOILSTINFORMATION TTREGPLA.NSAVAILABLE AT THE ONLYY LOCATE THE SOIL TYPES WITH OFFICE. T1H? ABBREVIATED SOIL NAMES. ACCORDING TO TUE USDA--SCS INVENTORY OF POTENTIAL WETLANDS AND USDI-NWS INVENTORY MAPS THERE (IS) THE TPQENTAL I OFDA WETLAND ON THIS SITE. MAPS MAY BE VIEWED nue ss- OFFICE.• PRIVATE CONSULTANTS WILL MAKE AN ON-SITE DETERMINATION. . 1. Drainage plan looks a little weak for 116th Street.____� 2 . Show f.OOCiwa'y" and f lood.Piain �,o'unda ies and eleva L ions. 3 . Label the easement that crosses the property. 4. Several rear yard swales exceed the recommended 500 ft. I will hold comment for the secondary plat. 5 . Improve drainage for 126th Street. 6. Will all lakes be lined or just the large one? I am concerned about the financial burden being put on the home owner if the liner fails. 7 . Will drainage facilities in Lake Forest addition have any impact? the lots? 3 . Is there sufficient "topsoiln to cover all 9 . Basements should be limited in the Westland soils. 10. Erosion control on the steeper slopes and poor Soils is a concern. ii . Storm drainage from Brookshire Village needs to be analyzed. Copies are being sent to the following: Nelson & gra- enbergger Steve Cash Randy Powell • file MAY 20 '91 01:51PM P. 1/1 A ' ;:4-•,1 ',A., .,..,...sdirlat., .........0677/R.'S 04, p.A.,1Ml' ,VIl #1161 /�' _ IIII1�U"polilijf I�11N --,.....,..„.<1(0/7 — p4' 07. j ) J�Gt-- 6-4 ', 1,i�it �), ((1] - �ti�.',, b X. �� t 1 I` i�' li I \ ►. •i �i ,c s�f- er_' ` •.�I �'. o f Itj,.F.. � ,L.. -�I t, IL I �i7i'irj l •:r :.rA .i • 1�� 'I � ll•lc 'Ili II.. ` ,'�i, (� +,_<< I (i � � (I;� �� .� ' i � 1•. ,1 � J I r1 •', c.D (;1ej ' -&'.- •---___::e `--rs- ,7,7„„14.:" ;• c.ruKto n C criliald cSutve of 94. nape cuvenue 776.96,26 N(ay ?0 > 1.9 91 `lo61esvir1le, �ndiana 46060 To: Schneider Re: Waterstone I have reviewed the primary plat for the above mentioned subdivision and I have the following comments. 1 . 4 permit from the DNR will be required in order to construct the outlets in the Cool Creek floodway. 2. The construction plans should show inverts and erosion control for the outlets into Cool Creek. 3 . We recommend SSD' s for swales with less than 2 percent slopes. 4 . Drainage calculations will be needed. 5 . Inverts will be needed for the outlets into and outfalls from the lakes. 6 . Minimum floor elevations should be shown on the construction plans. 7. Has permission to work within the Indiana Gas easement been obtained? 8 . please indicate the plan for flood routing. 9 . Swales should not exceed 500' in length from the high point to an adequate inlet. See lots 53-92 in Windpoint, lots 10-18 in Bayhill and lots 1-6 in Windpoint. 10 . There are six section corners located near this site. If construction may disturb these corners, please contact Jim Wyant, Monumentation Specialist, at 776-9626, thirty days prior to work so that measures can be taken to insure their integrity. If you have any questions, please contact me at 776-9626 or Fax at 776-9628. Sincerely Steven T. Cash, Plan Reviewer STC/jh cc: Carmel DOCD Jim Nelson SCS Co. Highway Randy Powell