HomeMy WebLinkAbout17060238.2GENERAL CONDITIONS
I. THE SCOPE OF WORK IS BASED ON THE CONSTRUCTION DOCUMENTS AND
SHALL INCLUDE THE FURNISHING OF MATERIALS AND LABOR REQUIRED FOR THE
COMPLETE PROJECT,
II. VISIT THE JOB SITE PRIOR TO SUBMITTING BID. CONTRACTOR SHALL WALK
THROUGH THE SITE WITH AN AUTHORIZED REPRESENTATIVE OF THE SHOPPING
CONSTRUCTION REQUIREMENTS.
I ENTER CONS
CENTER AND REVIEW SHOPPING C
COORDINATE WORK WITH THE SHOPPING CENTER WITH REGARD TO
TEMPORARY UTILITIES, ALLOWABLE MATERIAL, TRAFFIC ROUTES, STORAGE OF
TOOLS AND MATERIALS, USE OF TOILET FACILITIES, HOURS IN WHICH WORK IS
ALLOWED, NOISE AND DUST CONTROL, CLEANUP AND OTHER MATTERS
REQUIRING ADHERENCE TO SHOPPING CENTER REQUIREMENTS.
III. REVIEW WITH THE LANDLORD'S REPRESENTATIVE THE MANNER IN WHICH ALL
CONNECTIONS TO STRUCTURE WILL BE MADE. NEW PENETRATIONS IN THE
BUILDING ENVELOPE OR STRUCTURE SHALL BE REVIEWED WITH THE LANDLORD
AND APPROVED IN WRITING. IF THE LANDLORD REQUIRES THAT PORTIONS OF
CONTRACTOR, WORK BE PERFORMED BY ITS OWN CO , INCLUDE COSTS ASSOCIATED
WITH THAT PORTION OF THE WORK IN BID UNLESS STATED OTHERWISE IN
WRITING BY TENANT.
IV. DURING PERFORMANCE OF WORK, BE RESPONSIBLE FOR PROVISION AND
MAINTENANCE OF WARNING SIGNS, LIGHT SIGNAL DEVICES, GUARD LIGHTS,
BARRICADES, GUARD RAILS, FENCES AND OTHER DEVICES, APPROPRIATELY
LOCATED ON AND AROUND THE JOB SITE WHICH GIVE PROPER AND
UNDERSTANDABLE WARNING TO PERSONS WITH REGARD TO HAZARDOUS
CONDITIONS, EQUIPMENT AND OPERATIONS BEING PERFORMED IN
CONJUNCTION WITH THE WORK,
V. EXISTING CONDITIONS AND DIMENSIONS MAY BE TAKEN FROM INFORMATION
FURNISHED BY THE LANDLORD. VERIFY LEASE SPACE DIMENSIONS AND
IDENTIFY DISCREPANCIES BETWEEN BUILDING ELEMENTS AND DRAWINGS
BEFORE COMMENCING CONSTRUCTION. DISCREPANCIES FOUND ON THE
DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR
ENGINEER.
VI. DISCREPANCIES IDENTIFIED DURING CONSTRUCTION SHALL BE IMMEDIATELY
BROUGHT TO THE ATTENTION OF THE ARCHITECT OR ENGINEER.
DISCREPANCIES IDENTIFIED DURING CONSTRUCTION WILL BE CLARIFIED BY
CHANGE ORDERS, CHANGE ORDER APPROVAL IS SUBJECT TO AUTHORIZATION
BY THE LANDLORD.
0)
J
3
VII.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COSTS INCURRED FOR
�
NONCOMPLIANCE WITH THESE CONTRACT DOCUMENTS. CONTRACTOR WILL NOT
O
BE ALLOWED CHANGE ORDERS FOR PROBLEMS ARISING FROM NEGLECT OF
>
PROVISIONS INCLUDED IN THESE CONDITIONS.
O
J
U
1:
Of i; �
m
I
VIII.
ACCOMPLISH THE WORK IN COMPLIANCE WITH THE RESTRICTIONS AND
O
REQUIREMENTS OF THE LANDLORD, WORK SHALL CONFORM WITH THE
O
r��•�
AMERICANS WITH DISABILITIES ACT AND APPLICABLE LOCAL AND STATE
tY
UJ
HANDICAPPED DISABILITY DESIGN REQUIREMENTS. VERIFY THAT THE WORK
•
O
COMPLIES WITH ALL APPLICABLE LOCAL AND STATE FIRE, SAFETY, HEALTH,
>.
n
ENERGY AND BUILDING CODE REQUIREMENTS.
N
Li
Z
N
O
IX.
REMOVE CONSTRUCTION RUBBISH, SCAFFOLDING, EQUIPMENT, TEMPORARY
U
O
J
PROTECTION, TEMPORARY FIELD STRUCTURES, AND OTHER MATERIALS OR
EQUIPMENT THAT WAS REQUIRED IN CONNECTION WITH THE CONSTRUCTION,
BUT NOT A PERMANENT PART THEREOF.
F(D
0
X.
SCAFFOLDING SHALL BE BUILT IN ACCORDANCE WITH REQUIREMENTS OF
U
FEDERAL, STATE, AND LOCAL LAWS. TEMPORARY SHORING REQUIRED FOR THE
REMOVAL OF EXISTING WORK FOR THE INSTALLATION OF NEW WORK SHALL BE
rl-
o0
INCLUDED IN THE CONTRACT. BE RESPONSIBLE FOR THIS WORK, CORRECT AND
N
REPAIR DAMAGES CAUSED BY IMPROPER SUPPORT OR FAILURE OF SHORING.
I\
I\
O
/
XI.
MAINTAIN ORDERLY HOUSEKEEPING DURING CONSTRUCTION, AND UPON
SUBSTANTIAL COMPLETION PERFORM FINAL CLEANUP. FINAL CLEANUP SHALL
O
INCLUDE THE FOLLOWING: SWEEP, DAMP MOP, AND WAX RESILIENT FLOORING.
a
DUST, DIRT, PAINT DRIPPINGS, OIL, GREASE, AND OTHER BLEMISHES SHALL BE
0
REMOVED FROM FINISHED SURFACES, INCLUDING PIPES AND EQUIPMENT.
3:
WINDOWS, GLASS UNITS, GLASS DOORS AND MIRRORS SHALL BE WASHED.
X
PAINT OVERRUNS AND PUTTY SMEARS SHALL BE REMOVED, AND HARDWARE
O
SHALL BE RUBBED CLEAN WITH FLANNEL CLOTH.
Q-
0
O
XII.
BE RESPONSIBLE FOR JOB SITE SAFETY AND WARRANT THAT THIS INTENT SHALL
BE MADE EVIDENT IN LANDLORD'S AGREEMENT WITH THE CONTRACTOR.
V)
O
XIII.
BE RESPONSIBLE TO THE SHOPPING CENTER FOR DAMAGES THAT OCCUR TO
THE LANDLORD'S FACILITIES BEFORE, DURING, OR AFTER CONSTRUCTION
3
PROCEDURES CAUSED BY CONTRACTOR, CONTRACTOR'S EMPLOYEES, OR
/n
SUBCONTRACTORS.
L_
XIV.
MANUFACTURER'S OF SPECIFIED ITEMS ARE NOTED FOR QUALITY AND DESIGN.
SUBSTITUTE PRODUCTS ARE SUBJECT TO APPROVAL BY ARCHITECT. THE
CONTRACTOR IS ENCOURAGED TO SUBMIT ALTERNATE PRODUCTS FOR
CONSIDERATION IN AN EFFORT TO REDUCE THE CONSTRUCTION COST OR TIME.
U
REASONABLE REQUESTS WILL BE REVIEWED FOR COMPLIANCE WITH THE INTENT
OF THE CONSTRUCTION DOCUMENTS.
iv
E
0
XV.
PRODUCTS AND MATERIALS SHALL BE INSTALLED IN STRICT CONFORMANCE
0
O
WITH THE MANUFACTURER'S PUBLISHED RECOMMENDATIONS. PROVIDE A COPY
OF THE MANUFACTURER'S INSTALLATION RECOMMENDATIONS UPON REQUEST
OF CONSTRUCTION MANAGER.
I
XVI.
THE LANDLORD WILL PROVIDE INSURANCE REQUIREMENTS PRIOR TO THE
(L_
BIDDING. EVIDENCE OF INSURANCE SHALL BE PROVIDED TO THE LANDLORD AT
O
THE TIME OF BID SUBMITTAL.
0
XVII.
APPLICABLE STANDARDS OF CONSTRUCTION INDUSTRY HAVE THE SAME FORCE
AND EFFECT ON PERFORMANCE OF THE WORK AS IF COPIED DIRECTLY INTO
M
CONTRACT DOCUMENTS OR BOUND AND PUBLISHED THEREWITH, COMPLY WITH
STANDARDS IN EFFECT ON THE DATE OF ISSUE OF THE CONTRACT DOCUMENTS,
UNLESS OTHERWISE INDICATED.
a
XVIII.
UPON COMPLETION OF THE WORK, COMPILE FOR AND DELIVER TO LANDLORD A
c0
COMPLETE SET OF RECORD DOCUMENTS. THIS SET OF DOCUMENTS SHALL
CONSIST OF RECORD SPECIFICATIONS AND RECORD DRAWINGS SHOWING THE
REPORTED LOCATION OF THE WORK.
I
XIX.
WARRANT MATERIALS AND WORKMANSHIP FOR A PERIOD OF (1) YEAR FROM
DATE OF ACCEPTANCE BY LANDLORD.
O
N
XX. THE ARCHITECT / ENGINEER SHALL REVIEW SHOP DRAWING SUBMISSIONS
N SOLELY FOR THEIR CONFORMANCE WITH THE DESIGN INTENT AND
CONFORMANCE WITH INFORMATION GIVEN IN THE CONSTRUCTION DOCUMENTS
(D THE ARCHITECT / ENGINEER SHALL NOT BE RESPONSIBLE FOR ASPECTS OF A
l� SHOP DRAWING SUBMISSION THAT AFFECT OR ARE AFFECTED BY THE MEANS,
METHODS, TECHNIQUES, SEQUENCES AND OPERATIONS OF THE
CONSTRUCTION, SAFETY PRECAUTIONS AND PROGRAMS INCIDENTAL THERETO.
CONTRACTOR SHALL REVIEW SHOP DRAWINGS WITH RESPECT TO THESE
+d CONDITIONS BEFORE SUBMITTING THEM TO THE ARCHITECT / ENGINEER.
C
tl
XXI. WHEN MODIFICATIONS TO EXISTING STRUCTURAL STEEL COMPONENTS OR THE
ADDITION OF NEW STRUCTURAL STEEL ARE REQUIRED, AND NOT INDICATED IN
THESE CONSTRUCTION DOCUMENTS IT SHALL BE THE RESPONSIBILITY OF THE
G.C. TO SECURE THE SERVICES OF A STRUCTURAL ENGINEER TO OBTAIN THE
NECESSARY APPROVALS.
XXII. THE CONTRACTOR SHALL BE RESPONSIBLE FOR BECOMING FAMILIAR WITH THE
PROJECT SCHEDULE AND DEADLINES, AND FOR ADVISING THE LANDLORD OF ALL
LONG LEAD ITEMS, THEIR ANTICIPATED DELIVERY DATES, AND ANY POTENTIAL
IMPACT TO THE PROJECT SCHEDULE.
XXIII. THE CONTRACTOR SHALL MAINTAIN A CURRENT AND COMPLETE SET OF
LANDLORD AND BUILDING DEPARTMENT APPROVED DRAWINGS (AS APPLICABLE)
ON SITE THROUGHOUT CONSTRUCTION DURATION FOR USE BY ALL TRADES.
XXIV. DRAWINGS SHALL NOT BE SCALED. DIMENSIONS SHALL GOVERN IN ALL CASES,
DIMENSIONS AT ENLARGED DETAILS TAKE PRECEDENCE OVER OTHER
DIMENSIONS.
XXV. NOTWITHSTANDING THE FOREGOING, TENANT'S REVIEW OF LANDLORD'S PLANS
AND SPECIFICATIONS, AND TENANT'S ACCEPTANCE OF THE PREMISES, SHALL IN
NO EVENT CREATE AN EXPRESSED OR IMPLIED CONFIRMATION THAT
LANDLORD'S PLANS AND SPECIFICATIONS, NOR LANDLORD'S BUILD -OUT OF THE
PREMISES IS IN ACCORDANCE WITH THE REQUIREMENTS OF APPLICABLE LAWS,
CODES, ORDINANCES, AND REGULATIONS, INCLUDING BUT NOT LIMITED TO THE
MOST CURRENT VERSION OF TITLE III OF THE AMERICANS WITH DISABILITIES
ACT.
SECTION 01110 - SUMMARY OF WORK
A. THE WORK OF THIS PROJECT INCLUDES CONSTRUCTION WORK SHOWN ON THE
DRAWINGS AND SPECIFIED HEREIN. BUT NOT NECESSARILY LIMITED TO
GENERAL CONSTRUCTION, MECHANICAL, ELECTRICAL.
B. EXECUTE THE WORK DESCRIBED IN THESE SPECIFICATIONS AND SHOWN ON THE
DRAWINGS, AND OTHER WORK NECESSARY TO COMPLETE THE PROJECT, IN A
THOROUGHLY SUBSTANTIAL AND WORKMANLIKE MANNER, BY PERSONS
THOROUGHLY EXPERIENCED IN THEIR PARTICULAR TRADE OR CRAFT.
C. FIELD VERIFY DIMENSIONS OF EXISTING CONDITIONS, IF ANY, THAT AFFECTS THE
WORK, TAKE RESPONSIBILITY FOR THE CORRECTNESS OF MEASUREMENTS AND
VERIFY GRADES, LINES, LEVELS, ELEVATIONS, AND DIMENSIONS SHOWN PRIOR
TO COMMENCING WORK.
D. CONSULT DRAWINGS AND PLAN WORK SO THAT THE EXCAVATED MATERIAL,
DEMOLISHED MATERIAL, NEW BUILDING MATERIALS, ETC. ARE NOT PLACED
WHERE THEY WILL INTERFERE WITH THE WORK OF OTHERS, OR WITH TENANTS
E. SHOULD IT APPEAR THAT THE WORK INTENDED TO BE DESCRIBED OR RELATED
WORK ARE NOT SUFFICIENTLY DETAILED OR EXPLAINED ON THE DRAWINGS, OR
IN THE SPECIFICATIONS, CONSULT THE ARCHITECT FOR NECESSARY
CLARIFICATIONS, AND CONFORM TO THOSE CLARIFICATIONS INSOFAR AS THEY
ARE CONSISTENT WITH THE ORIGINAL DRAWINGS AND SPECIFICATIONS. IN NO
CASE SHALL WORK PROCEED IN UNCERTAINTY.
F. THOSE PERFORMING WORK AS A SUBCONTRACTOR MUST EXAMINE
SUBSTRATES AND CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED
AND NOTIFY THE CONTRACTOR IN WRITING, OF CONDITIONS DETRIMENTAL TO
THE PROPER AND TIMELY COMPLETION OF THE WORK, COMMENCEMENT OF
WORK BY A TRADE ON A SURFACE OR CONSTRUCTION SHALL IMPLY
ACCEPTANCE OF SUCH SURFACE OR CONSTRUCTION. DO NOT PROCEED WITH
INSTALLATION UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED.
G. ITEMS INDICATED AS "N.I.C." (NOT IN CONTRACT), OR "EXISTING" SHALL NOT BE
INCLUDED IN THE CONTRACT, HOWEVER, CONTRACTOR WILL BE RESPONSIBLE
FOR VERIFYING CONDITION OF SUCH ITEMS AND COORDINATING WORK THAT
AFFECTS OR IS AFFECTED BY THESE ITEMS.
H. TENANT FURNISHED -CONTRACTOR INSTALLED PRODUCTS (MATERIALS,
PRODUCTS OR EQUIPMENT)
1. CONTRACTOR SHALL BE RESPONSIBLE FOR RECEIVING, STORING,
HANDLING, AND INSTALLING ITEMS PROVIDED BY TENANT. CONTRACTOR
SHALL INSPECT SHIPMENTS UPON DELIVERY FOR DAMAGE AND SHALL
VERIFY THAT QUANTITIES ARE ACCURATE AND IN COMPLIANCE WITH BILL OF
LADING. CONTRACTOR SHALL BE RESPONSIBLE FOR FILING SHIPPING
DAMAGE CLAIMS AGAINST THE CARRIER IN CASE OF RECEIPT OF DAMAGED
ITEMS. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR OR
REPLACEMENT OF DAMAGED ITEMS UPON ACCEPTANCE OF DELIVERY AT
PROJECT SITE. CONTRACTOR SHALL PROTECT THE ITEMS FROM DAMAGE
THROUGHOUT THE CONSTRUCTION PERIOD UNTIL TURN OVER OF SPACE.
2. TENANT WILL FURNISH THE PRODUCTS AS DELINEATED IN THE SCHEDULE OF
RESPONSIBILITIES. THESE PRODUCTS WILL BE DELIVERED TO THE SITE
WHERE THE CONTRACTOR SHALL RECEIVE, UNLOAD, STRIP AND INSTALL
THEM.
I' TENANT PROVIDED PRODUCTS (MATERIALS, PRODUCTS OR EQUIPMENT)
1. TENANT WILL PROVIDE, FURNISH AND INSTALL CERTAIN ITEMS AS
DELINEATED IN THE SCHEDULE OF RESPONSIBILITIES. THE CONTRACTOR
SHALL COORDINATE HIS WORK WITH WORK BEING PERFORMED BY TENANT'S
VENDORS, INSTALLERS, AND SUBCONTRACTORS.
J. ALL WORK IS TO BE PERFORMED TO INDUSTRY STANDARDS BY QUALIFIED,
COMPETENT TRADESPERSONS. IT IS ASSUMED THAT WORKERS WILL BE
FAMILIAR WITH LOCAL, STATE, AND NATIONAL CODES AND REGULATIONS AND
SHALL ADHERE TO SUCH CODES AND REGULATIONS. IN MUNCIPALITIES
REQUIREING LICENSING IT IS ASSUMED THAT EACH TRADE SHALL HAVE A
PROPERLY LICENSED PERSON PERFORMING THE WORK.
K. FIRE PROTECTION SYSTEM DESIGN AND MODIFICATIONS ARE TO BE BY THE FIRE
PROTECTION CONTRACTOR, INCLUDING PREPARATION AND SUBMISSION OF
DESIGN DRAWINGS, SECURING OF ALL NECESSARY PERMITS, AND THE
RESPONSIBILITY FOR OBTAINING SYSTEM APPROVAL.
L. DEFINITIONS
1. IDENTIFICATION
REFER TO THE CONTRACT FOR NAME, LOCATION, PROJECT NUMBER AND
ABBREVIATED IDENTIFICATION OF THE WORK FOR THE PROJECT.
2. CONTRACT DOCUMENTS
REQUIREMENTS OF THE WORK ARE CONTAINED IN THE CONTRACT
DOCUMENTS, AND INCLUDE CROSS-REFERENCES HEREIN TO PUBLISH
INFORMATION, WHICH IS NOT NECESSARILY BOUND HEREWITH.
3. CUTTING AND PATCHING
STRUCTURAL WORK
DO NOT CUT AND PATCH STRUCTURAL WORK IN A MANNER RESULTING IN A
REDUCTION OF LOAD CARRYING CAPACITY OF LOAD DEFLECTION RATIO,
SUBMIT PROPOSAL, REQUEST AND OBTAIN ARCHITECT'S / ENGINEER'S
APPROVAL BEFORE PROCEEDING WITH CUT AND PATCHING AN
UNSATISFACTORY MANNER, AS JUDGED BY ARCHITECT / ENGINEER.
4. EXCAVATING AND BACKFILLING FOR MEP WORK
COMPLY WITH APPICABLE PROVISIONS OF DIVISION 2..
5. DEFINITIONS AND STANDARDS
FURNISH, SUPPLY AND DELIVER TO PROJECT SITE, READY FOR UNLOADING,
UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR SUBSEQUENT
REQUIREMENTS,
6. INSTALL
OPERATIONS AT PROJECT SITE, READY FOR UNLOADING, UNPACKING,
ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING, WORKING, TO
DIMENSION, FINISHING, CURING, PROTECTING, CLEANING AND SIMILAR
REQUIREMENTS.
7. PROVIDE
FURNISH AND INSTALL, COMPLETE AND READY FOR INTENDED USE
8. INSTALLER
ENTITY (FIRM OR ACTUAL PERSON) ENGAGED TO INSTALL WORK BY
CONTRACTOR, SUBCONTRACTOR OR SUB -CONTRACTOR, INSTALLERS ARE
REQUIRED TO BE SKILLED IN WORK THEY ARE ENGAGED TO INSTALL.
9. SPECIFICATION FORMAT
OVERLAPPING / CONFLICTING REQUIREMENTS
MOST STRINGENT (GENERALLY MOST COSTLY) APPLIES AND WILL BE ENFORCED,
UNLESS MORE DETAILED LANGUAGE WRITTEN DIRECTLY INTO THE CONTRACT
DOCUMENTS CLEARLY INDICATES UNCERTAINTIES TO ARCHITECT / ENGINEER
FOR DECISION BEFORE PROCEEDING. WHERE OPTIONAL REQUIREMENTS ARE
SPECIFIED IN A PARALLEL MANNER, OPTION IS INTENDED TO BE CONTRACTOR'S
UNLESS OTHERWISE INDICATED.
10. MINIMUM REQUIREMENTS
INDICATED REQUIREMENTS ARE FOR A SPECIFIC MINIMUM ACCEPTABLE LEVEL
OF QUALITY / QUANTITY, AS RECOGNIZED IN THE INDUSTRY. ACTUAL WORK
MUST COMPLY (WITHIN SPECIFIED TOLERANCIES) TO STANDARDS CALLED
FORTH IN PLANS AND SPECIFICATION, ANY UNCERTAINTIES ARE TO BE
CLARIFIED WITH ARCHITECT / ENGINEER PRIOR TO PROCEEDING.
11. ABBREVIATION, PLURAL WORDS
ABBREVIATIONS, WHERE NOT DEFINED IN CONTRACT DOCUMENTS, WILL BE
INTERPRETED TO MEAN NORMAL CONSTRUCTION INDUSTRY TERMINOLOGY
DETERMINED BY RECOGNIZED GRAMMATICAL RULES BY THE
ARCHITECT/ENGINEER, PLURAL WORDS WILL BE INTERPRETED AS PLURAL
WHERE APPLICABLE FOR THE CONTEXT OF THE CONTRACT DOCUMENTS.
12, TESTING LABORATORY
AN INDEPENDENT ENTITY ENGAGED FOR THE PROJECT TO PROVIDE
INSPECTIONS, TEST, INTERPRETATIONS, REPORTS AND SIMILAR SERVICES.
13. STANDARDS AND REGULATIONS
APPLICABLE STANDARDS OF CONSTRUCTION INDUSTRY HAVE SAME FORCE
EFFECT ON PERFORMANCES AS IF THEY WERE COPIED DIRECTLY INTO
CONTRACT DOCUMENTS OR BOUND AND PUBLISHED HEREWITH. STANDARDS
REFERENCED TO CONTRACT DOCUMENTS OR IN GOVERNING REGULATIONS
HAVE PRECEDENCE OVER NON -REFERENCED STANDARDS IN SO FAR AS DIRECT
STANDARDS MAY CONTAIN OVERLAPPING OR CONFLICTING REQUIREMENTS,
COMPLY WITH STANDARDS IN EFFECT AS OF DATE OF CONTRACT DOCUMENTS
UNLESS OTHERWISE NOTED.
14. PROCEDURE AND CONTROLS
ADMINISTRATION AND SUPERVISION
COORDINATE VARIOUS ELEMENTS OF THE WORK AND ENTITIES ENGAGED WORK.
COORDINATE THE WORK WITH EXISTING FACILITIES/CONDITIONS, AND WITH
WORK BY SEPERATE CONTRACTORS (IF ANY) AND BY OWNER.
15. INSTALLER INSPECTIONS
REQUIRE INSTALLER OF EACH MAJOR UNIT OF WORK TO INSPECT SUBSTRATE
AND CONDITIONS FOR INSTALLATION, AND TO REPORT IN WRITING,
UNSATISFACTORY CONDITIONS. CORRECT UNSATISFACTORY CONDITIONS
BEFORE PROCEEDING. INSPECT EACH PRODUCT IMMEDIATELY BEFORE
INSTALLATION, AND DO NOT INSTALL DAMAGED OR DEFECTIVE PRODUCTS,
MATERIALS OR EQUIPMENT.
16. TIMING
INSTALL WORK DURING TIME AND UNDER CONDITIONS WHICH WILL ENSURE
BEST POSSIBLE RESULTS. CORRDINATED WITH REQUIRED INSPECTION AND
TESTING.
17. ANCHOR WORK SECURELY IN PLACE PROPERLY LOCATED BY MEASURED LINE
LEVEL, ORGANIZED FOR BEST POSSIBLE UNIFORMITY, VISUAL EFFECT,
OPERATIONAL EFFICIENCY, DURABILITY AND SIMILAR SIMILAR BENEFIT TO
OWNERS USE. ISOLATE NON -COMPATIBLE MATERIALS FROM CONTACT,
SUFFICIENTLY TO PREVENT DETERIORATION.
18. MOUNT INDIVIDUAL UNITS OF WORK AT INDUSTRY RECOGNIZED MOUNTING
HEIGHTS IF NOT OTHERWISE INDICATED. REFER UNCERTAINTIES TO
ARCHITECT/ENGINEER PRIOR TO PROCEEDING.
19. CLEANING AND PROTECTION
CLEAN EACH ELEMENT OF WORK AT TIME OF INSTALLATION. PROVIDE
SUFFICIENT MAINTENANCE AND PROTECTION DURING CONSTRUCTION TO
ENSURE FREEDOM AND PREVENTDETERIORATION AT TIME OF SUBSTANTIAL
COMPLETION,
20. SUBMITTALS
WORK SUBMITTALS
THE PROVISIONS OF THIS SECTION APPLY TO REQUIRED SUBMITTALS RELATED
TO UNITS OF WORK AND NOT TO ADMINISTRATIVE SUBMITTALS WHICH INCLUDE
PAYMENT REQUESTS, INSURANCE CERTIFICATES AND PROGRESS REPORTS.
21 SPECIAL PROJECT WARRANTIES
TWO (2) EXECUTED COPIES PLUS CONFIRMED COPIES AS REQUIRED IN
MAINTENANCE MANUALS.
22 MAINTENANCE MANUALS
TWO (2) BOUND COPIES
23 RECORD DRAWINGS
ORIGINAL MAINTAINED MARKED -UP PRINTS, PLUS TWO (2) PHOTOGRAPHIC
COPIES WHICH MAY AT CONTRACTORS OPTION, BE REPRODUCED TO NOT LESS
THAN HALF SIZE (50% REDUCTION IN WIDTH AND LENGTH).
SECTION 01110 - CUTTING AND PATCHING
A. REQUIREMENTS FOR STRUCTURAL WORK. DO NOT CUT AND PATCH
STRUCTURAL ELEMENTS IN A MANNER THAT WOULD CHANGE THEIR
LOAD -CARRYING CAPACITY OR LOAD -DEFLECTION RATIO.
B. VISUAL REQUIREMENTS: DO NOT CUT AND PATCH CONSTRUCTION EXPOSED ON
THE EXTERIOR OR IN OCCUPIED SPACES IN A MANNER THAT WOULD, IN THE
ARCHITECT'S OPINION, REDUCE THE BUILDING'S AESTHETIC QUALITIES. DO NOT
CUT AND PATCH CONSTRUCTION IN A MANNER THAT WOULD RESULT IN VISUAL
EVIDENCE OF CUTTING AND PATCHING. REMOVE CONSTRUCTION CUT AND
PATCH IN A VISUALLY SATISFACTORY MANNER, AND REPLACE WITH A
CONSTRUCTION VISUALLY ACCEPTABLE TO THE ARCHITECT.
SECTION 02060 - EXISTING CONDITIONS
A. CONTRACTOR IS TO VISIT THE SITE TO INSPECT THE EXISTING CONDITIONS AND
TO VERIFY THE AMOUNT OF WORK THAT WILL BE NECESSARY FOR THE PROJECT
TO BE COMPLETED AS SHOWN ON THE ARCHITECTURAL AND ENGINEERING
DRAWINGS.
B. NOTIFY THE ARCHITECT IMMEDIATELY UPON ENCOUNTERING UNEXPECTED
CONCEALED CONDITIONS AND, EXCEPT IN AN EMERGENCY, BEFORE THE
ENCOUNTERED CONDITIONS ARE DISTURBED.
SPACE A22D
9,329 SF
YK�];�iT;�►I•I:�
DEMOLITION & BARRICADES
LANDLORD SHALL PROVIDE A TEMPORARY CONSTRUCTION BARRICADE PER
MALL REQUIREMENTS, FULLY FINISHED, PAINTED AND READY TO RECEIVE
TENANT'S GRAPHICS.
LANDLORD SHALL DEMOLISH ALL PRIOR TENANT FIXTURES, FURNISHINGS AND
EQUIPMENT.
LANDLORD SHALL DEMOLISH THE EXISTING STOREFRONT AT THE NEW SLAB
INFILL LOCATION ONLY.
CONCRETE FLOOR SLAB
LANDLORD SHALL PROVIDE A CONCRETE FLOOR SLAB IN COMPLIANCE WITH
LOCAL AND FEDERAL CODES.
LANDLORD SHALL RAISE THE LOWER SLAB -ON -GRADE APPROXIMATELY TWO
FEET TO ALIGN WITH THE EXISTING HIGHER SLAB. THE VOID CAN BE FILLED WITH
EITHER STONE/GRAVEL OR STRUCTURAL FOAM.
LANDLORD SHALL INSTALL A NEW CONCRETE STEM WALL ON THE FRONT SIDE
OF THE SLAB INFILL AS A SUPPORT FOR THE NEW STOREFRONT AND A
BULKHEAD FOR THE SLAB.
MASONRY
LANDLORD SHALL FILL IN EXISTING REAR DOORS OR OPENINGS IN THE AREA OF
THE SLAB INFILL ONLY.
INTERIOR PARTITIONS & GYPSUM BOARD ON EXTERIOR WALLS
INSTALL GREEN BOARD AT PERIMETER WALLS FOR NEW SLAB INFILL.
EXISTING DEMISING WALLS TO REMAIN.
STOREFRONT AND DOORS
LANDLORD SHALL PROVIDE A NEW STOREFRONT AT THE LOCATION OF THE SLAB
INFILL TO MATCH ADJACENT SPACE.
ELECTRICAL
LANDLORD SHALL PROVIDE ANY REQUIRED EMERGENCY LIGHTS.
LANDLORD SHALL ADJUST/MODIFY ANY EXISTING ELECTRICAL COMPONENTS AS
A RESULT OF THE SLAB INFILL.
PLUMBING & SPRINKLER
LANDLORD SHALL ADJUST SPRINKLER HEADS BY TURNING THEM UP TO MEET
CODE.
LANDLORD SHALL ADJUST SANITARY CONNECTION AS REQUIRED DUE TO SLAB
INFILL.
FIRE PROTECTION WORK NOTES
FIRE PROTECTION SHALL BE PART OF THE MECHANICAL CONTRACT BY THE MALL
APPROVED FIRE PROTECTION CONTRACTOR.
AN EXISTING FIRE PROTECTION SYSTEM IS INSTALLED WITHIN THE PROPOSED
LEASE SPACE. ADD PIPING AND HEADS AS REQUIRED TO ACCOMMODATE NEW
PARTITIONS, CEILING HEIGHTS, AND HEAD TYPES.
SPRINKLER HEADS IN FINISHED AREAS SHALL BE CHROME PLATED PENDANT
TYPE. SPRINKLER HEADS IN BULKHEADS SHALL BE FULLY CONCEALED POP -OUT
TYPE, VIKING A-1 OR EQUAL. PAINT TO MATCH CEILING. SPRINKLER HEADS IN
UNFINISHED AREAS SHALL BE ROUGH BRASS PENDANT TYPE.
SPRINKLER SUBCONTRACTOR SHALL INCLUDE LAYOUT DRAWINGS AND ALL
REQUIRED MALL AND AGENCY APPROVALS AS PART OF THE WORK.
ALL WORK SHALL CONFORM TO NFPA AS WELL AS ANY OTHER APPLICABLE
CODES.
PLANS MUST BE SUBMITTED WHICH VERIFY THAT THE FIRE SPRINKLER
PROTECTION IS STILL ADEQUATE AFTER REMODEL, AND COMPLIES WITH UBC
STANDARDS 38-1 (UBC 3801) AND OTHER APPLICABLE CODES AS A MINIMUM.
SUBMIT SPRINKLER SYSTEM DRAWINGS AND SPECIFICATIONS.
CONFIRM LOCATION OF LEASE LINE WITH LANDLORD PRIOR TO COMMENCING
WITH DEMOLITION.
COORDINATE WORK AND SCHEDULE WITH THE MALL MANAGEMENT OFFICE OR
DESIGNATED LANDLORD REPRESENTATIVE.
PROTECT ALL AREAS NOT INCLUDED
IN THE WORK, ANY DAMAGE THAT OCCURS
AS A RESULT OF THE WORK SHALL BE REPAIRED TO A LIKE NEW CONDITION.
NOTIFY THE ARCHITECT AT ONCE OF ANY UNFORESEEN HAZARD BEFORE
DEMOLITION IS COMPLETE. THE REMOVAL AND/OR HANDLING OF HAZARDOUS
MATERIALS IS NOT PART OF WORK, IF ANY DISTURBANCE OF HAZARDOUS
MATERIAL IS ANTICIPATED BY THIS WORK, AUTHORITIES MUST BE NOTIFIED AND
PREDESCRIBED PROCEDURES MUST BE FOLLOWED.
NO ALTERATIONS TO THE EXISTING STRUCTURAL MEMBERS ARE ALLOWED
UNLESS SPECIFICALLY APPROVED IN WRITING BY THE LANDLORD.
ALL CONDITIONS AND DIMENSIONS SHOWN ARE FOR REFERENCE ONLY AND
MUST BE FIELD VERIFIED. UPON COMPLETION OF THE DEMOLITION ALL
CONDITIONS AND DIMENSIONS ARE TO BE CHECKED FOR VARIANCES. REPORT
ANY DISCREPANCY TO THE ARCHITECT, ANY UNREPORTED CONDITIONS WHICH
MAY CONFLICT WITH THE PURPOSED NEW WORK AND MAY REQUIRE
MODIFICATION, RELOCATION AND/OR REMOVAL SHALL BE IDENTIFIED AND
REPORTED TO THE ARCHITECT FOR DETERMINATION OF BEST COURSE OF
ACTION.
REFER TO THE ARCHITECTURAL DRAWINGS FOR SCOPE OF NEW WORK AND TO
CONFIRM TERMINATION AND / OR REMOVAL OF EXISTING FIXTURES, DEVICES
AND SERVICES.
ANY MODIFICATION TO EXISTING SPRINKLER SYSTEM MUST BE PERFORMED BY
LANDLORD'S APPROVED SPRINKLER CONTRACTOR, APPROVED BY LOCAL FIRE
MARSHAL AND COORDINATED WITH MALL MANAGEMENT.
COORDINATE WITH MALL'S APPROVED VENDOR'S ANY WORK THAT AFFECTS THE
EXISTING ROOF, SPRINKLER SYSTEM, FIRE ALARM SYSTEM AND OTHER FIRE
PROTECTION SYSTEMS BEFORE STARTING DEMOLITION,
MAINTAIN OR REPAIR ANY FIRE RATED ASSEMBLIES AND SEPARATIONS
INCLUDING BUT NOT LIMITED TO DEMISING WALLS, CEILINGS, FIRESTOPS AND
FIRE RETARDANT TREATED BLOCKING.
REPAIR ANY DAMAGE THAT OCCURS DURING DEMOLITION TO ANY SYSTEM OR
ASSEMBLY THAT IS SLATED TO REMAIN,
DO NOT ABANDON ANY UTILITIES OR MATERIALS WITHIN THE LEASE LINES -
REMOVE SERVICES ETC. BACK TO SOURCE.
ALL DEMOLISHED MATERIALS ARE TO BE REMOVED FROM THE SITE BY
APPROVED METHODS.
GENERAL CONSTRUCTION NOTES
1. REFER TO DEMOLITION PLAN(S) FOR EXTENT OF WORK TO BE PERFORMED IN
THIS AREA PRIOR TO THE CONSTRUCTION OF NEW DEMISTING WALL.
DEMOLITION MUST BE COMPLETE PARTICULARLY IN THOSE AREAS WHERE NEW
CONSTRUCTION IS SCHEDULED TO BE PERFORMED.
2. INSPECT THE CONDITION OF EXISTING DEMISING PARTITIONS AND EXTERIOR
GLAZING WALLS AND PROVIDE FULL HEIGHT AND FINISHED PARTITION TO
UNDERSIDE OF DECK AS REQUIRED. PATCH AND REPAIR TO ACHIEVE OR
MAINTAIN REQUIRED FIRE RATING - TAPE AND SPACKLE TO PREPARE FOR
FINISHES.
3. UPON POSSESSION OF THE PREMISES, DIMENSIONS OF SPACE SHALL BE
VERIFIED. G.C. SHALL SUBMIT NOTED DISCREPANCIES TO THE ARCHITECT
WITHIN THREE DAYS OF THE START OF CONSTRUCTION.
4. WHEN RE -USING EXISTING DRYWALL CONSTRUCTION, PATCH AND REPAIR
WALLS AS NECESSARY TO ENSURE REQUIRED RATING. PATCH ALL VOIDS
INCLUDING DECK FLUTES WITH NON-COMBUSTIPLE MATERIALS.
5, REFER TO PARTITION SCHEDULE FOR WALL CONSTRUCTION
6. ALL DIMENSIONS ON PLAN FOR NEW INTERIOR LAYOUTS ARE FROM FINISHED
WALL TO FINISHED WALL UNLESS NOTED OTHERWISE.
7. PATCH AND FIRESTOP GWB PARTITIONS AS REQUIRED BY LOCAL CODES
8. ALL PENETRATIONS OF FIRE RESISTIVE FLOORS OR SHAFT WALLS SHALL BE
PROTECTED BY MATERIALS AND INSTALLATIONS DETAILS THAT CONFORM TO UL
STANDARDS FOR THROUGH PENETRATIONS FIRE STOP SYSTEMS. THE
CONTRACTOR SHALL SUBMIT SHOP DRAWING DETAILS WHICH SHOW COMPLETE
CONFORMANCE TO THE UL LISTING TO THE ARCHITECT, SUCH DRAWINGS SHALL
BE AVAILABLE TO ANY CITY INSPECTORS. THE DRAWINGS SHALL BE SPECIFIC
FOR EACH PENETRATION WITH ALL VARIABLES DEFINED.
WOOLPERT
Architecture I Engineering I Geospatial
7635 Interactive Way
Suite 100
Indianapolis, IN 46278
317.299.7500
WASHINGTON
PRIME GROUP"
180 East Broad Street
Columbus, OH 43215
washingtonprime.com
x.40"' M. Arte a
. G\STFR�9��
* AR 19600170
STATE OF j
0
(D
w
� W
a V
z �
O �
~w
z �
z >=
<U)
�
� U
J
J
�
i
O
U
a �
r .
0
J
r_Yx�
1:
Of i; �
m
O�
v
vJ
r��•�
Add
0,00
tY
UJ
N
•
O
CO
>.
n
J
Z
N
O
o,
Q
N
Q
M
J
SPACE A22D
9,329 SF
YK�];�iT;�►I•I:�
DEMOLITION & BARRICADES
LANDLORD SHALL PROVIDE A TEMPORARY CONSTRUCTION BARRICADE PER
MALL REQUIREMENTS, FULLY FINISHED, PAINTED AND READY TO RECEIVE
TENANT'S GRAPHICS.
LANDLORD SHALL DEMOLISH ALL PRIOR TENANT FIXTURES, FURNISHINGS AND
EQUIPMENT.
LANDLORD SHALL DEMOLISH THE EXISTING STOREFRONT AT THE NEW SLAB
INFILL LOCATION ONLY.
CONCRETE FLOOR SLAB
LANDLORD SHALL PROVIDE A CONCRETE FLOOR SLAB IN COMPLIANCE WITH
LOCAL AND FEDERAL CODES.
LANDLORD SHALL RAISE THE LOWER SLAB -ON -GRADE APPROXIMATELY TWO
FEET TO ALIGN WITH THE EXISTING HIGHER SLAB. THE VOID CAN BE FILLED WITH
EITHER STONE/GRAVEL OR STRUCTURAL FOAM.
LANDLORD SHALL INSTALL A NEW CONCRETE STEM WALL ON THE FRONT SIDE
OF THE SLAB INFILL AS A SUPPORT FOR THE NEW STOREFRONT AND A
BULKHEAD FOR THE SLAB.
MASONRY
LANDLORD SHALL FILL IN EXISTING REAR DOORS OR OPENINGS IN THE AREA OF
THE SLAB INFILL ONLY.
INTERIOR PARTITIONS & GYPSUM BOARD ON EXTERIOR WALLS
INSTALL GREEN BOARD AT PERIMETER WALLS FOR NEW SLAB INFILL.
EXISTING DEMISING WALLS TO REMAIN.
STOREFRONT AND DOORS
LANDLORD SHALL PROVIDE A NEW STOREFRONT AT THE LOCATION OF THE SLAB
INFILL TO MATCH ADJACENT SPACE.
ELECTRICAL
LANDLORD SHALL PROVIDE ANY REQUIRED EMERGENCY LIGHTS.
LANDLORD SHALL ADJUST/MODIFY ANY EXISTING ELECTRICAL COMPONENTS AS
A RESULT OF THE SLAB INFILL.
PLUMBING & SPRINKLER
LANDLORD SHALL ADJUST SPRINKLER HEADS BY TURNING THEM UP TO MEET
CODE.
LANDLORD SHALL ADJUST SANITARY CONNECTION AS REQUIRED DUE TO SLAB
INFILL.
FIRE PROTECTION WORK NOTES
FIRE PROTECTION SHALL BE PART OF THE MECHANICAL CONTRACT BY THE MALL
APPROVED FIRE PROTECTION CONTRACTOR.
AN EXISTING FIRE PROTECTION SYSTEM IS INSTALLED WITHIN THE PROPOSED
LEASE SPACE. ADD PIPING AND HEADS AS REQUIRED TO ACCOMMODATE NEW
PARTITIONS, CEILING HEIGHTS, AND HEAD TYPES.
SPRINKLER HEADS IN FINISHED AREAS SHALL BE CHROME PLATED PENDANT
TYPE. SPRINKLER HEADS IN BULKHEADS SHALL BE FULLY CONCEALED POP -OUT
TYPE, VIKING A-1 OR EQUAL. PAINT TO MATCH CEILING. SPRINKLER HEADS IN
UNFINISHED AREAS SHALL BE ROUGH BRASS PENDANT TYPE.
SPRINKLER SUBCONTRACTOR SHALL INCLUDE LAYOUT DRAWINGS AND ALL
REQUIRED MALL AND AGENCY APPROVALS AS PART OF THE WORK.
ALL WORK SHALL CONFORM TO NFPA AS WELL AS ANY OTHER APPLICABLE
CODES.
PLANS MUST BE SUBMITTED WHICH VERIFY THAT THE FIRE SPRINKLER
PROTECTION IS STILL ADEQUATE AFTER REMODEL, AND COMPLIES WITH UBC
STANDARDS 38-1 (UBC 3801) AND OTHER APPLICABLE CODES AS A MINIMUM.
SUBMIT SPRINKLER SYSTEM DRAWINGS AND SPECIFICATIONS.
CONFIRM LOCATION OF LEASE LINE WITH LANDLORD PRIOR TO COMMENCING
WITH DEMOLITION.
COORDINATE WORK AND SCHEDULE WITH THE MALL MANAGEMENT OFFICE OR
DESIGNATED LANDLORD REPRESENTATIVE.
PROTECT ALL AREAS NOT INCLUDED
IN THE WORK, ANY DAMAGE THAT OCCURS
AS A RESULT OF THE WORK SHALL BE REPAIRED TO A LIKE NEW CONDITION.
NOTIFY THE ARCHITECT AT ONCE OF ANY UNFORESEEN HAZARD BEFORE
DEMOLITION IS COMPLETE. THE REMOVAL AND/OR HANDLING OF HAZARDOUS
MATERIALS IS NOT PART OF WORK, IF ANY DISTURBANCE OF HAZARDOUS
MATERIAL IS ANTICIPATED BY THIS WORK, AUTHORITIES MUST BE NOTIFIED AND
PREDESCRIBED PROCEDURES MUST BE FOLLOWED.
NO ALTERATIONS TO THE EXISTING STRUCTURAL MEMBERS ARE ALLOWED
UNLESS SPECIFICALLY APPROVED IN WRITING BY THE LANDLORD.
ALL CONDITIONS AND DIMENSIONS SHOWN ARE FOR REFERENCE ONLY AND
MUST BE FIELD VERIFIED. UPON COMPLETION OF THE DEMOLITION ALL
CONDITIONS AND DIMENSIONS ARE TO BE CHECKED FOR VARIANCES. REPORT
ANY DISCREPANCY TO THE ARCHITECT, ANY UNREPORTED CONDITIONS WHICH
MAY CONFLICT WITH THE PURPOSED NEW WORK AND MAY REQUIRE
MODIFICATION, RELOCATION AND/OR REMOVAL SHALL BE IDENTIFIED AND
REPORTED TO THE ARCHITECT FOR DETERMINATION OF BEST COURSE OF
ACTION.
REFER TO THE ARCHITECTURAL DRAWINGS FOR SCOPE OF NEW WORK AND TO
CONFIRM TERMINATION AND / OR REMOVAL OF EXISTING FIXTURES, DEVICES
AND SERVICES.
ANY MODIFICATION TO EXISTING SPRINKLER SYSTEM MUST BE PERFORMED BY
LANDLORD'S APPROVED SPRINKLER CONTRACTOR, APPROVED BY LOCAL FIRE
MARSHAL AND COORDINATED WITH MALL MANAGEMENT.
COORDINATE WITH MALL'S APPROVED VENDOR'S ANY WORK THAT AFFECTS THE
EXISTING ROOF, SPRINKLER SYSTEM, FIRE ALARM SYSTEM AND OTHER FIRE
PROTECTION SYSTEMS BEFORE STARTING DEMOLITION,
MAINTAIN OR REPAIR ANY FIRE RATED ASSEMBLIES AND SEPARATIONS
INCLUDING BUT NOT LIMITED TO DEMISING WALLS, CEILINGS, FIRESTOPS AND
FIRE RETARDANT TREATED BLOCKING.
REPAIR ANY DAMAGE THAT OCCURS DURING DEMOLITION TO ANY SYSTEM OR
ASSEMBLY THAT IS SLATED TO REMAIN,
DO NOT ABANDON ANY UTILITIES OR MATERIALS WITHIN THE LEASE LINES -
REMOVE SERVICES ETC. BACK TO SOURCE.
ALL DEMOLISHED MATERIALS ARE TO BE REMOVED FROM THE SITE BY
APPROVED METHODS.
GENERAL CONSTRUCTION NOTES
1. REFER TO DEMOLITION PLAN(S) FOR EXTENT OF WORK TO BE PERFORMED IN
THIS AREA PRIOR TO THE CONSTRUCTION OF NEW DEMISTING WALL.
DEMOLITION MUST BE COMPLETE PARTICULARLY IN THOSE AREAS WHERE NEW
CONSTRUCTION IS SCHEDULED TO BE PERFORMED.
2. INSPECT THE CONDITION OF EXISTING DEMISING PARTITIONS AND EXTERIOR
GLAZING WALLS AND PROVIDE FULL HEIGHT AND FINISHED PARTITION TO
UNDERSIDE OF DECK AS REQUIRED. PATCH AND REPAIR TO ACHIEVE OR
MAINTAIN REQUIRED FIRE RATING - TAPE AND SPACKLE TO PREPARE FOR
FINISHES.
3. UPON POSSESSION OF THE PREMISES, DIMENSIONS OF SPACE SHALL BE
VERIFIED. G.C. SHALL SUBMIT NOTED DISCREPANCIES TO THE ARCHITECT
WITHIN THREE DAYS OF THE START OF CONSTRUCTION.
4. WHEN RE -USING EXISTING DRYWALL CONSTRUCTION, PATCH AND REPAIR
WALLS AS NECESSARY TO ENSURE REQUIRED RATING. PATCH ALL VOIDS
INCLUDING DECK FLUTES WITH NON-COMBUSTIPLE MATERIALS.
5, REFER TO PARTITION SCHEDULE FOR WALL CONSTRUCTION
6. ALL DIMENSIONS ON PLAN FOR NEW INTERIOR LAYOUTS ARE FROM FINISHED
WALL TO FINISHED WALL UNLESS NOTED OTHERWISE.
7. PATCH AND FIRESTOP GWB PARTITIONS AS REQUIRED BY LOCAL CODES
8. ALL PENETRATIONS OF FIRE RESISTIVE FLOORS OR SHAFT WALLS SHALL BE
PROTECTED BY MATERIALS AND INSTALLATIONS DETAILS THAT CONFORM TO UL
STANDARDS FOR THROUGH PENETRATIONS FIRE STOP SYSTEMS. THE
CONTRACTOR SHALL SUBMIT SHOP DRAWING DETAILS WHICH SHOW COMPLETE
CONFORMANCE TO THE UL LISTING TO THE ARCHITECT, SUCH DRAWINGS SHALL
BE AVAILABLE TO ANY CITY INSPECTORS. THE DRAWINGS SHALL BE SPECIFIC
FOR EACH PENETRATION WITH ALL VARIABLES DEFINED.
WOOLPERT
Architecture I Engineering I Geospatial
7635 Interactive Way
Suite 100
Indianapolis, IN 46278
317.299.7500
WASHINGTON
PRIME GROUP"
180 East Broad Street
Columbus, OH 43215
washingtonprime.com
x.40"' M. Arte a
. G\STFR�9��
* AR 19600170
STATE OF j
0
(D
w
� W
a V
z �
O �
~w
z �
z >=
<U)
�
� U
J
REV DATE DESCRIPTION
02/23/2017 PERMIT SET
Pro= 077287
01/30/2017
Sheet Name:
Sheet Name;
PROJECT
SPECIFICATIONS
G-002
J
�
a
O
U
Y
J
L.L
m
O�
v
vJ
n
CY)
tY
UJ
N
H
O
CO
>.
J
Z
N
O
o,
Q
N
Q
M
J
REV DATE DESCRIPTION
02/23/2017 PERMIT SET
Pro= 077287
01/30/2017
Sheet Name:
Sheet Name;
PROJECT
SPECIFICATIONS