Loading...
HomeMy WebLinkAbout17060238.2GENERAL CONDITIONS I. THE SCOPE OF WORK IS BASED ON THE CONSTRUCTION DOCUMENTS AND SHALL INCLUDE THE FURNISHING OF MATERIALS AND LABOR REQUIRED FOR THE COMPLETE PROJECT, II. VISIT THE JOB SITE PRIOR TO SUBMITTING BID. CONTRACTOR SHALL WALK THROUGH THE SITE WITH AN AUTHORIZED REPRESENTATIVE OF THE SHOPPING CONSTRUCTION REQUIREMENTS. I ENTER CONS CENTER AND REVIEW SHOPPING C COORDINATE WORK WITH THE SHOPPING CENTER WITH REGARD TO TEMPORARY UTILITIES, ALLOWABLE MATERIAL, TRAFFIC ROUTES, STORAGE OF TOOLS AND MATERIALS, USE OF TOILET FACILITIES, HOURS IN WHICH WORK IS ALLOWED, NOISE AND DUST CONTROL, CLEANUP AND OTHER MATTERS REQUIRING ADHERENCE TO SHOPPING CENTER REQUIREMENTS. III. REVIEW WITH THE LANDLORD'S REPRESENTATIVE THE MANNER IN WHICH ALL CONNECTIONS TO STRUCTURE WILL BE MADE. NEW PENETRATIONS IN THE BUILDING ENVELOPE OR STRUCTURE SHALL BE REVIEWED WITH THE LANDLORD AND APPROVED IN WRITING. IF THE LANDLORD REQUIRES THAT PORTIONS OF CONTRACTOR, WORK BE PERFORMED BY ITS OWN CO , INCLUDE COSTS ASSOCIATED WITH THAT PORTION OF THE WORK IN BID UNLESS STATED OTHERWISE IN WRITING BY TENANT. IV. DURING PERFORMANCE OF WORK, BE RESPONSIBLE FOR PROVISION AND MAINTENANCE OF WARNING SIGNS, LIGHT SIGNAL DEVICES, GUARD LIGHTS, BARRICADES, GUARD RAILS, FENCES AND OTHER DEVICES, APPROPRIATELY LOCATED ON AND AROUND THE JOB SITE WHICH GIVE PROPER AND UNDERSTANDABLE WARNING TO PERSONS WITH REGARD TO HAZARDOUS CONDITIONS, EQUIPMENT AND OPERATIONS BEING PERFORMED IN CONJUNCTION WITH THE WORK, V. EXISTING CONDITIONS AND DIMENSIONS MAY BE TAKEN FROM INFORMATION FURNISHED BY THE LANDLORD. VERIFY LEASE SPACE DIMENSIONS AND IDENTIFY DISCREPANCIES BETWEEN BUILDING ELEMENTS AND DRAWINGS BEFORE COMMENCING CONSTRUCTION. DISCREPANCIES FOUND ON THE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR ENGINEER. VI. DISCREPANCIES IDENTIFIED DURING CONSTRUCTION SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ARCHITECT OR ENGINEER. DISCREPANCIES IDENTIFIED DURING CONSTRUCTION WILL BE CLARIFIED BY CHANGE ORDERS, CHANGE ORDER APPROVAL IS SUBJECT TO AUTHORIZATION BY THE LANDLORD. 0) J 3 VII. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COSTS INCURRED FOR � NONCOMPLIANCE WITH THESE CONTRACT DOCUMENTS. CONTRACTOR WILL NOT O BE ALLOWED CHANGE ORDERS FOR PROBLEMS ARISING FROM NEGLECT OF > PROVISIONS INCLUDED IN THESE CONDITIONS. O J U 1: Of i; � m I VIII. ACCOMPLISH THE WORK IN COMPLIANCE WITH THE RESTRICTIONS AND O REQUIREMENTS OF THE LANDLORD, WORK SHALL CONFORM WITH THE O r��•� AMERICANS WITH DISABILITIES ACT AND APPLICABLE LOCAL AND STATE tY UJ HANDICAPPED DISABILITY DESIGN REQUIREMENTS. VERIFY THAT THE WORK • O COMPLIES WITH ALL APPLICABLE LOCAL AND STATE FIRE, SAFETY, HEALTH, >. n ENERGY AND BUILDING CODE REQUIREMENTS. N Li Z N O IX. REMOVE CONSTRUCTION RUBBISH, SCAFFOLDING, EQUIPMENT, TEMPORARY U O J PROTECTION, TEMPORARY FIELD STRUCTURES, AND OTHER MATERIALS OR EQUIPMENT THAT WAS REQUIRED IN CONNECTION WITH THE CONSTRUCTION, BUT NOT A PERMANENT PART THEREOF. F(D 0 X. SCAFFOLDING SHALL BE BUILT IN ACCORDANCE WITH REQUIREMENTS OF U FEDERAL, STATE, AND LOCAL LAWS. TEMPORARY SHORING REQUIRED FOR THE REMOVAL OF EXISTING WORK FOR THE INSTALLATION OF NEW WORK SHALL BE rl- o0 INCLUDED IN THE CONTRACT. BE RESPONSIBLE FOR THIS WORK, CORRECT AND N REPAIR DAMAGES CAUSED BY IMPROPER SUPPORT OR FAILURE OF SHORING. I\ I\ O / XI. MAINTAIN ORDERLY HOUSEKEEPING DURING CONSTRUCTION, AND UPON SUBSTANTIAL COMPLETION PERFORM FINAL CLEANUP. FINAL CLEANUP SHALL O INCLUDE THE FOLLOWING: SWEEP, DAMP MOP, AND WAX RESILIENT FLOORING. a DUST, DIRT, PAINT DRIPPINGS, OIL, GREASE, AND OTHER BLEMISHES SHALL BE 0 REMOVED FROM FINISHED SURFACES, INCLUDING PIPES AND EQUIPMENT. 3: WINDOWS, GLASS UNITS, GLASS DOORS AND MIRRORS SHALL BE WASHED. X PAINT OVERRUNS AND PUTTY SMEARS SHALL BE REMOVED, AND HARDWARE O SHALL BE RUBBED CLEAN WITH FLANNEL CLOTH. Q- 0 O XII. BE RESPONSIBLE FOR JOB SITE SAFETY AND WARRANT THAT THIS INTENT SHALL BE MADE EVIDENT IN LANDLORD'S AGREEMENT WITH THE CONTRACTOR. V) O XIII. BE RESPONSIBLE TO THE SHOPPING CENTER FOR DAMAGES THAT OCCUR TO THE LANDLORD'S FACILITIES BEFORE, DURING, OR AFTER CONSTRUCTION 3 PROCEDURES CAUSED BY CONTRACTOR, CONTRACTOR'S EMPLOYEES, OR /n SUBCONTRACTORS. L_ XIV. MANUFACTURER'S OF SPECIFIED ITEMS ARE NOTED FOR QUALITY AND DESIGN. SUBSTITUTE PRODUCTS ARE SUBJECT TO APPROVAL BY ARCHITECT. THE CONTRACTOR IS ENCOURAGED TO SUBMIT ALTERNATE PRODUCTS FOR CONSIDERATION IN AN EFFORT TO REDUCE THE CONSTRUCTION COST OR TIME. U REASONABLE REQUESTS WILL BE REVIEWED FOR COMPLIANCE WITH THE INTENT OF THE CONSTRUCTION DOCUMENTS. iv E 0 XV. PRODUCTS AND MATERIALS SHALL BE INSTALLED IN STRICT CONFORMANCE 0 O WITH THE MANUFACTURER'S PUBLISHED RECOMMENDATIONS. PROVIDE A COPY OF THE MANUFACTURER'S INSTALLATION RECOMMENDATIONS UPON REQUEST OF CONSTRUCTION MANAGER. I XVI. THE LANDLORD WILL PROVIDE INSURANCE REQUIREMENTS PRIOR TO THE (L_ BIDDING. EVIDENCE OF INSURANCE SHALL BE PROVIDED TO THE LANDLORD AT O THE TIME OF BID SUBMITTAL. 0 XVII. APPLICABLE STANDARDS OF CONSTRUCTION INDUSTRY HAVE THE SAME FORCE AND EFFECT ON PERFORMANCE OF THE WORK AS IF COPIED DIRECTLY INTO M CONTRACT DOCUMENTS OR BOUND AND PUBLISHED THEREWITH, COMPLY WITH STANDARDS IN EFFECT ON THE DATE OF ISSUE OF THE CONTRACT DOCUMENTS, UNLESS OTHERWISE INDICATED. a XVIII. UPON COMPLETION OF THE WORK, COMPILE FOR AND DELIVER TO LANDLORD A c0 COMPLETE SET OF RECORD DOCUMENTS. THIS SET OF DOCUMENTS SHALL CONSIST OF RECORD SPECIFICATIONS AND RECORD DRAWINGS SHOWING THE REPORTED LOCATION OF THE WORK. I XIX. WARRANT MATERIALS AND WORKMANSHIP FOR A PERIOD OF (1) YEAR FROM DATE OF ACCEPTANCE BY LANDLORD. O N XX. THE ARCHITECT / ENGINEER SHALL REVIEW SHOP DRAWING SUBMISSIONS N SOLELY FOR THEIR CONFORMANCE WITH THE DESIGN INTENT AND CONFORMANCE WITH INFORMATION GIVEN IN THE CONSTRUCTION DOCUMENTS (D THE ARCHITECT / ENGINEER SHALL NOT BE RESPONSIBLE FOR ASPECTS OF A l� SHOP DRAWING SUBMISSION THAT AFFECT OR ARE AFFECTED BY THE MEANS, METHODS, TECHNIQUES, SEQUENCES AND OPERATIONS OF THE CONSTRUCTION, SAFETY PRECAUTIONS AND PROGRAMS INCIDENTAL THERETO. CONTRACTOR SHALL REVIEW SHOP DRAWINGS WITH RESPECT TO THESE +d CONDITIONS BEFORE SUBMITTING THEM TO THE ARCHITECT / ENGINEER. C tl XXI. WHEN MODIFICATIONS TO EXISTING STRUCTURAL STEEL COMPONENTS OR THE ADDITION OF NEW STRUCTURAL STEEL ARE REQUIRED, AND NOT INDICATED IN THESE CONSTRUCTION DOCUMENTS IT SHALL BE THE RESPONSIBILITY OF THE G.C. TO SECURE THE SERVICES OF A STRUCTURAL ENGINEER TO OBTAIN THE NECESSARY APPROVALS. XXII. THE CONTRACTOR SHALL BE RESPONSIBLE FOR BECOMING FAMILIAR WITH THE PROJECT SCHEDULE AND DEADLINES, AND FOR ADVISING THE LANDLORD OF ALL LONG LEAD ITEMS, THEIR ANTICIPATED DELIVERY DATES, AND ANY POTENTIAL IMPACT TO THE PROJECT SCHEDULE. XXIII. THE CONTRACTOR SHALL MAINTAIN A CURRENT AND COMPLETE SET OF LANDLORD AND BUILDING DEPARTMENT APPROVED DRAWINGS (AS APPLICABLE) ON SITE THROUGHOUT CONSTRUCTION DURATION FOR USE BY ALL TRADES. XXIV. DRAWINGS SHALL NOT BE SCALED. DIMENSIONS SHALL GOVERN IN ALL CASES, DIMENSIONS AT ENLARGED DETAILS TAKE PRECEDENCE OVER OTHER DIMENSIONS. XXV. NOTWITHSTANDING THE FOREGOING, TENANT'S REVIEW OF LANDLORD'S PLANS AND SPECIFICATIONS, AND TENANT'S ACCEPTANCE OF THE PREMISES, SHALL IN NO EVENT CREATE AN EXPRESSED OR IMPLIED CONFIRMATION THAT LANDLORD'S PLANS AND SPECIFICATIONS, NOR LANDLORD'S BUILD -OUT OF THE PREMISES IS IN ACCORDANCE WITH THE REQUIREMENTS OF APPLICABLE LAWS, CODES, ORDINANCES, AND REGULATIONS, INCLUDING BUT NOT LIMITED TO THE MOST CURRENT VERSION OF TITLE III OF THE AMERICANS WITH DISABILITIES ACT. SECTION 01110 - SUMMARY OF WORK A. THE WORK OF THIS PROJECT INCLUDES CONSTRUCTION WORK SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. BUT NOT NECESSARILY LIMITED TO GENERAL CONSTRUCTION, MECHANICAL, ELECTRICAL. B. EXECUTE THE WORK DESCRIBED IN THESE SPECIFICATIONS AND SHOWN ON THE DRAWINGS, AND OTHER WORK NECESSARY TO COMPLETE THE PROJECT, IN A THOROUGHLY SUBSTANTIAL AND WORKMANLIKE MANNER, BY PERSONS THOROUGHLY EXPERIENCED IN THEIR PARTICULAR TRADE OR CRAFT. C. FIELD VERIFY DIMENSIONS OF EXISTING CONDITIONS, IF ANY, THAT AFFECTS THE WORK, TAKE RESPONSIBILITY FOR THE CORRECTNESS OF MEASUREMENTS AND VERIFY GRADES, LINES, LEVELS, ELEVATIONS, AND DIMENSIONS SHOWN PRIOR TO COMMENCING WORK. D. CONSULT DRAWINGS AND PLAN WORK SO THAT THE EXCAVATED MATERIAL, DEMOLISHED MATERIAL, NEW BUILDING MATERIALS, ETC. ARE NOT PLACED WHERE THEY WILL INTERFERE WITH THE WORK OF OTHERS, OR WITH TENANTS E. SHOULD IT APPEAR THAT THE WORK INTENDED TO BE DESCRIBED OR RELATED WORK ARE NOT SUFFICIENTLY DETAILED OR EXPLAINED ON THE DRAWINGS, OR IN THE SPECIFICATIONS, CONSULT THE ARCHITECT FOR NECESSARY CLARIFICATIONS, AND CONFORM TO THOSE CLARIFICATIONS INSOFAR AS THEY ARE CONSISTENT WITH THE ORIGINAL DRAWINGS AND SPECIFICATIONS. IN NO CASE SHALL WORK PROCEED IN UNCERTAINTY. F. THOSE PERFORMING WORK AS A SUBCONTRACTOR MUST EXAMINE SUBSTRATES AND CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED AND NOTIFY THE CONTRACTOR IN WRITING, OF CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY COMPLETION OF THE WORK, COMMENCEMENT OF WORK BY A TRADE ON A SURFACE OR CONSTRUCTION SHALL IMPLY ACCEPTANCE OF SUCH SURFACE OR CONSTRUCTION. DO NOT PROCEED WITH INSTALLATION UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. G. ITEMS INDICATED AS "N.I.C." (NOT IN CONTRACT), OR "EXISTING" SHALL NOT BE INCLUDED IN THE CONTRACT, HOWEVER, CONTRACTOR WILL BE RESPONSIBLE FOR VERIFYING CONDITION OF SUCH ITEMS AND COORDINATING WORK THAT AFFECTS OR IS AFFECTED BY THESE ITEMS. H. TENANT FURNISHED -CONTRACTOR INSTALLED PRODUCTS (MATERIALS, PRODUCTS OR EQUIPMENT) 1. CONTRACTOR SHALL BE RESPONSIBLE FOR RECEIVING, STORING, HANDLING, AND INSTALLING ITEMS PROVIDED BY TENANT. CONTRACTOR SHALL INSPECT SHIPMENTS UPON DELIVERY FOR DAMAGE AND SHALL VERIFY THAT QUANTITIES ARE ACCURATE AND IN COMPLIANCE WITH BILL OF LADING. CONTRACTOR SHALL BE RESPONSIBLE FOR FILING SHIPPING DAMAGE CLAIMS AGAINST THE CARRIER IN CASE OF RECEIPT OF DAMAGED ITEMS. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR OR REPLACEMENT OF DAMAGED ITEMS UPON ACCEPTANCE OF DELIVERY AT PROJECT SITE. CONTRACTOR SHALL PROTECT THE ITEMS FROM DAMAGE THROUGHOUT THE CONSTRUCTION PERIOD UNTIL TURN OVER OF SPACE. 2. TENANT WILL FURNISH THE PRODUCTS AS DELINEATED IN THE SCHEDULE OF RESPONSIBILITIES. THESE PRODUCTS WILL BE DELIVERED TO THE SITE WHERE THE CONTRACTOR SHALL RECEIVE, UNLOAD, STRIP AND INSTALL THEM. I' TENANT PROVIDED PRODUCTS (MATERIALS, PRODUCTS OR EQUIPMENT) 1. TENANT WILL PROVIDE, FURNISH AND INSTALL CERTAIN ITEMS AS DELINEATED IN THE SCHEDULE OF RESPONSIBILITIES. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH WORK BEING PERFORMED BY TENANT'S VENDORS, INSTALLERS, AND SUBCONTRACTORS. J. ALL WORK IS TO BE PERFORMED TO INDUSTRY STANDARDS BY QUALIFIED, COMPETENT TRADESPERSONS. IT IS ASSUMED THAT WORKERS WILL BE FAMILIAR WITH LOCAL, STATE, AND NATIONAL CODES AND REGULATIONS AND SHALL ADHERE TO SUCH CODES AND REGULATIONS. IN MUNCIPALITIES REQUIREING LICENSING IT IS ASSUMED THAT EACH TRADE SHALL HAVE A PROPERLY LICENSED PERSON PERFORMING THE WORK. K. FIRE PROTECTION SYSTEM DESIGN AND MODIFICATIONS ARE TO BE BY THE FIRE PROTECTION CONTRACTOR, INCLUDING PREPARATION AND SUBMISSION OF DESIGN DRAWINGS, SECURING OF ALL NECESSARY PERMITS, AND THE RESPONSIBILITY FOR OBTAINING SYSTEM APPROVAL. L. DEFINITIONS 1. IDENTIFICATION REFER TO THE CONTRACT FOR NAME, LOCATION, PROJECT NUMBER AND ABBREVIATED IDENTIFICATION OF THE WORK FOR THE PROJECT. 2. CONTRACT DOCUMENTS REQUIREMENTS OF THE WORK ARE CONTAINED IN THE CONTRACT DOCUMENTS, AND INCLUDE CROSS-REFERENCES HEREIN TO PUBLISH INFORMATION, WHICH IS NOT NECESSARILY BOUND HEREWITH. 3. CUTTING AND PATCHING STRUCTURAL WORK DO NOT CUT AND PATCH STRUCTURAL WORK IN A MANNER RESULTING IN A REDUCTION OF LOAD CARRYING CAPACITY OF LOAD DEFLECTION RATIO, SUBMIT PROPOSAL, REQUEST AND OBTAIN ARCHITECT'S / ENGINEER'S APPROVAL BEFORE PROCEEDING WITH CUT AND PATCHING AN UNSATISFACTORY MANNER, AS JUDGED BY ARCHITECT / ENGINEER. 4. EXCAVATING AND BACKFILLING FOR MEP WORK COMPLY WITH APPICABLE PROVISIONS OF DIVISION 2.. 5. DEFINITIONS AND STANDARDS FURNISH, SUPPLY AND DELIVER TO PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR SUBSEQUENT REQUIREMENTS, 6. INSTALL OPERATIONS AT PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING, WORKING, TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING AND SIMILAR REQUIREMENTS. 7. PROVIDE FURNISH AND INSTALL, COMPLETE AND READY FOR INTENDED USE 8. INSTALLER ENTITY (FIRM OR ACTUAL PERSON) ENGAGED TO INSTALL WORK BY CONTRACTOR, SUBCONTRACTOR OR SUB -CONTRACTOR, INSTALLERS ARE REQUIRED TO BE SKILLED IN WORK THEY ARE ENGAGED TO INSTALL. 9. SPECIFICATION FORMAT OVERLAPPING / CONFLICTING REQUIREMENTS MOST STRINGENT (GENERALLY MOST COSTLY) APPLIES AND WILL BE ENFORCED, UNLESS MORE DETAILED LANGUAGE WRITTEN DIRECTLY INTO THE CONTRACT DOCUMENTS CLEARLY INDICATES UNCERTAINTIES TO ARCHITECT / ENGINEER FOR DECISION BEFORE PROCEEDING. WHERE OPTIONAL REQUIREMENTS ARE SPECIFIED IN A PARALLEL MANNER, OPTION IS INTENDED TO BE CONTRACTOR'S UNLESS OTHERWISE INDICATED. 10. MINIMUM REQUIREMENTS INDICATED REQUIREMENTS ARE FOR A SPECIFIC MINIMUM ACCEPTABLE LEVEL OF QUALITY / QUANTITY, AS RECOGNIZED IN THE INDUSTRY. ACTUAL WORK MUST COMPLY (WITHIN SPECIFIED TOLERANCIES) TO STANDARDS CALLED FORTH IN PLANS AND SPECIFICATION, ANY UNCERTAINTIES ARE TO BE CLARIFIED WITH ARCHITECT / ENGINEER PRIOR TO PROCEEDING. 11. ABBREVIATION, PLURAL WORDS ABBREVIATIONS, WHERE NOT DEFINED IN CONTRACT DOCUMENTS, WILL BE INTERPRETED TO MEAN NORMAL CONSTRUCTION INDUSTRY TERMINOLOGY DETERMINED BY RECOGNIZED GRAMMATICAL RULES BY THE ARCHITECT/ENGINEER, PLURAL WORDS WILL BE INTERPRETED AS PLURAL WHERE APPLICABLE FOR THE CONTEXT OF THE CONTRACT DOCUMENTS. 12, TESTING LABORATORY AN INDEPENDENT ENTITY ENGAGED FOR THE PROJECT TO PROVIDE INSPECTIONS, TEST, INTERPRETATIONS, REPORTS AND SIMILAR SERVICES. 13. STANDARDS AND REGULATIONS APPLICABLE STANDARDS OF CONSTRUCTION INDUSTRY HAVE SAME FORCE EFFECT ON PERFORMANCES AS IF THEY WERE COPIED DIRECTLY INTO CONTRACT DOCUMENTS OR BOUND AND PUBLISHED HEREWITH. STANDARDS REFERENCED TO CONTRACT DOCUMENTS OR IN GOVERNING REGULATIONS HAVE PRECEDENCE OVER NON -REFERENCED STANDARDS IN SO FAR AS DIRECT STANDARDS MAY CONTAIN OVERLAPPING OR CONFLICTING REQUIREMENTS, COMPLY WITH STANDARDS IN EFFECT AS OF DATE OF CONTRACT DOCUMENTS UNLESS OTHERWISE NOTED. 14. PROCEDURE AND CONTROLS ADMINISTRATION AND SUPERVISION COORDINATE VARIOUS ELEMENTS OF THE WORK AND ENTITIES ENGAGED WORK. COORDINATE THE WORK WITH EXISTING FACILITIES/CONDITIONS, AND WITH WORK BY SEPERATE CONTRACTORS (IF ANY) AND BY OWNER. 15. INSTALLER INSPECTIONS REQUIRE INSTALLER OF EACH MAJOR UNIT OF WORK TO INSPECT SUBSTRATE AND CONDITIONS FOR INSTALLATION, AND TO REPORT IN WRITING, UNSATISFACTORY CONDITIONS. CORRECT UNSATISFACTORY CONDITIONS BEFORE PROCEEDING. INSPECT EACH PRODUCT IMMEDIATELY BEFORE INSTALLATION, AND DO NOT INSTALL DAMAGED OR DEFECTIVE PRODUCTS, MATERIALS OR EQUIPMENT. 16. TIMING INSTALL WORK DURING TIME AND UNDER CONDITIONS WHICH WILL ENSURE BEST POSSIBLE RESULTS. CORRDINATED WITH REQUIRED INSPECTION AND TESTING. 17. ANCHOR WORK SECURELY IN PLACE PROPERLY LOCATED BY MEASURED LINE LEVEL, ORGANIZED FOR BEST POSSIBLE UNIFORMITY, VISUAL EFFECT, OPERATIONAL EFFICIENCY, DURABILITY AND SIMILAR SIMILAR BENEFIT TO OWNERS USE. ISOLATE NON -COMPATIBLE MATERIALS FROM CONTACT, SUFFICIENTLY TO PREVENT DETERIORATION. 18. MOUNT INDIVIDUAL UNITS OF WORK AT INDUSTRY RECOGNIZED MOUNTING HEIGHTS IF NOT OTHERWISE INDICATED. REFER UNCERTAINTIES TO ARCHITECT/ENGINEER PRIOR TO PROCEEDING. 19. CLEANING AND PROTECTION CLEAN EACH ELEMENT OF WORK AT TIME OF INSTALLATION. PROVIDE SUFFICIENT MAINTENANCE AND PROTECTION DURING CONSTRUCTION TO ENSURE FREEDOM AND PREVENTDETERIORATION AT TIME OF SUBSTANTIAL COMPLETION, 20. SUBMITTALS WORK SUBMITTALS THE PROVISIONS OF THIS SECTION APPLY TO REQUIRED SUBMITTALS RELATED TO UNITS OF WORK AND NOT TO ADMINISTRATIVE SUBMITTALS WHICH INCLUDE PAYMENT REQUESTS, INSURANCE CERTIFICATES AND PROGRESS REPORTS. 21 SPECIAL PROJECT WARRANTIES TWO (2) EXECUTED COPIES PLUS CONFIRMED COPIES AS REQUIRED IN MAINTENANCE MANUALS. 22 MAINTENANCE MANUALS TWO (2) BOUND COPIES 23 RECORD DRAWINGS ORIGINAL MAINTAINED MARKED -UP PRINTS, PLUS TWO (2) PHOTOGRAPHIC COPIES WHICH MAY AT CONTRACTORS OPTION, BE REPRODUCED TO NOT LESS THAN HALF SIZE (50% REDUCTION IN WIDTH AND LENGTH). SECTION 01110 - CUTTING AND PATCHING A. REQUIREMENTS FOR STRUCTURAL WORK. DO NOT CUT AND PATCH STRUCTURAL ELEMENTS IN A MANNER THAT WOULD CHANGE THEIR LOAD -CARRYING CAPACITY OR LOAD -DEFLECTION RATIO. B. VISUAL REQUIREMENTS: DO NOT CUT AND PATCH CONSTRUCTION EXPOSED ON THE EXTERIOR OR IN OCCUPIED SPACES IN A MANNER THAT WOULD, IN THE ARCHITECT'S OPINION, REDUCE THE BUILDING'S AESTHETIC QUALITIES. DO NOT CUT AND PATCH CONSTRUCTION IN A MANNER THAT WOULD RESULT IN VISUAL EVIDENCE OF CUTTING AND PATCHING. REMOVE CONSTRUCTION CUT AND PATCH IN A VISUALLY SATISFACTORY MANNER, AND REPLACE WITH A CONSTRUCTION VISUALLY ACCEPTABLE TO THE ARCHITECT. SECTION 02060 - EXISTING CONDITIONS A. CONTRACTOR IS TO VISIT THE SITE TO INSPECT THE EXISTING CONDITIONS AND TO VERIFY THE AMOUNT OF WORK THAT WILL BE NECESSARY FOR THE PROJECT TO BE COMPLETED AS SHOWN ON THE ARCHITECTURAL AND ENGINEERING DRAWINGS. B. NOTIFY THE ARCHITECT IMMEDIATELY UPON ENCOUNTERING UNEXPECTED CONCEALED CONDITIONS AND, EXCEPT IN AN EMERGENCY, BEFORE THE ENCOUNTERED CONDITIONS ARE DISTURBED. SPACE A22D 9,329 SF YK�];�iT;�►I•I:� DEMOLITION & BARRICADES LANDLORD SHALL PROVIDE A TEMPORARY CONSTRUCTION BARRICADE PER MALL REQUIREMENTS, FULLY FINISHED, PAINTED AND READY TO RECEIVE TENANT'S GRAPHICS. LANDLORD SHALL DEMOLISH ALL PRIOR TENANT FIXTURES, FURNISHINGS AND EQUIPMENT. LANDLORD SHALL DEMOLISH THE EXISTING STOREFRONT AT THE NEW SLAB INFILL LOCATION ONLY. CONCRETE FLOOR SLAB LANDLORD SHALL PROVIDE A CONCRETE FLOOR SLAB IN COMPLIANCE WITH LOCAL AND FEDERAL CODES. LANDLORD SHALL RAISE THE LOWER SLAB -ON -GRADE APPROXIMATELY TWO FEET TO ALIGN WITH THE EXISTING HIGHER SLAB. THE VOID CAN BE FILLED WITH EITHER STONE/GRAVEL OR STRUCTURAL FOAM. LANDLORD SHALL INSTALL A NEW CONCRETE STEM WALL ON THE FRONT SIDE OF THE SLAB INFILL AS A SUPPORT FOR THE NEW STOREFRONT AND A BULKHEAD FOR THE SLAB. MASONRY LANDLORD SHALL FILL IN EXISTING REAR DOORS OR OPENINGS IN THE AREA OF THE SLAB INFILL ONLY. INTERIOR PARTITIONS & GYPSUM BOARD ON EXTERIOR WALLS INSTALL GREEN BOARD AT PERIMETER WALLS FOR NEW SLAB INFILL. EXISTING DEMISING WALLS TO REMAIN. STOREFRONT AND DOORS LANDLORD SHALL PROVIDE A NEW STOREFRONT AT THE LOCATION OF THE SLAB INFILL TO MATCH ADJACENT SPACE. ELECTRICAL LANDLORD SHALL PROVIDE ANY REQUIRED EMERGENCY LIGHTS. LANDLORD SHALL ADJUST/MODIFY ANY EXISTING ELECTRICAL COMPONENTS AS A RESULT OF THE SLAB INFILL. PLUMBING & SPRINKLER LANDLORD SHALL ADJUST SPRINKLER HEADS BY TURNING THEM UP TO MEET CODE. LANDLORD SHALL ADJUST SANITARY CONNECTION AS REQUIRED DUE TO SLAB INFILL. FIRE PROTECTION WORK NOTES FIRE PROTECTION SHALL BE PART OF THE MECHANICAL CONTRACT BY THE MALL APPROVED FIRE PROTECTION CONTRACTOR. AN EXISTING FIRE PROTECTION SYSTEM IS INSTALLED WITHIN THE PROPOSED LEASE SPACE. ADD PIPING AND HEADS AS REQUIRED TO ACCOMMODATE NEW PARTITIONS, CEILING HEIGHTS, AND HEAD TYPES. SPRINKLER HEADS IN FINISHED AREAS SHALL BE CHROME PLATED PENDANT TYPE. SPRINKLER HEADS IN BULKHEADS SHALL BE FULLY CONCEALED POP -OUT TYPE, VIKING A-1 OR EQUAL. PAINT TO MATCH CEILING. SPRINKLER HEADS IN UNFINISHED AREAS SHALL BE ROUGH BRASS PENDANT TYPE. SPRINKLER SUBCONTRACTOR SHALL INCLUDE LAYOUT DRAWINGS AND ALL REQUIRED MALL AND AGENCY APPROVALS AS PART OF THE WORK. ALL WORK SHALL CONFORM TO NFPA AS WELL AS ANY OTHER APPLICABLE CODES. PLANS MUST BE SUBMITTED WHICH VERIFY THAT THE FIRE SPRINKLER PROTECTION IS STILL ADEQUATE AFTER REMODEL, AND COMPLIES WITH UBC STANDARDS 38-1 (UBC 3801) AND OTHER APPLICABLE CODES AS A MINIMUM. SUBMIT SPRINKLER SYSTEM DRAWINGS AND SPECIFICATIONS. CONFIRM LOCATION OF LEASE LINE WITH LANDLORD PRIOR TO COMMENCING WITH DEMOLITION. COORDINATE WORK AND SCHEDULE WITH THE MALL MANAGEMENT OFFICE OR DESIGNATED LANDLORD REPRESENTATIVE. PROTECT ALL AREAS NOT INCLUDED IN THE WORK, ANY DAMAGE THAT OCCURS AS A RESULT OF THE WORK SHALL BE REPAIRED TO A LIKE NEW CONDITION. NOTIFY THE ARCHITECT AT ONCE OF ANY UNFORESEEN HAZARD BEFORE DEMOLITION IS COMPLETE. THE REMOVAL AND/OR HANDLING OF HAZARDOUS MATERIALS IS NOT PART OF WORK, IF ANY DISTURBANCE OF HAZARDOUS MATERIAL IS ANTICIPATED BY THIS WORK, AUTHORITIES MUST BE NOTIFIED AND PREDESCRIBED PROCEDURES MUST BE FOLLOWED. NO ALTERATIONS TO THE EXISTING STRUCTURAL MEMBERS ARE ALLOWED UNLESS SPECIFICALLY APPROVED IN WRITING BY THE LANDLORD. ALL CONDITIONS AND DIMENSIONS SHOWN ARE FOR REFERENCE ONLY AND MUST BE FIELD VERIFIED. UPON COMPLETION OF THE DEMOLITION ALL CONDITIONS AND DIMENSIONS ARE TO BE CHECKED FOR VARIANCES. REPORT ANY DISCREPANCY TO THE ARCHITECT, ANY UNREPORTED CONDITIONS WHICH MAY CONFLICT WITH THE PURPOSED NEW WORK AND MAY REQUIRE MODIFICATION, RELOCATION AND/OR REMOVAL SHALL BE IDENTIFIED AND REPORTED TO THE ARCHITECT FOR DETERMINATION OF BEST COURSE OF ACTION. REFER TO THE ARCHITECTURAL DRAWINGS FOR SCOPE OF NEW WORK AND TO CONFIRM TERMINATION AND / OR REMOVAL OF EXISTING FIXTURES, DEVICES AND SERVICES. ANY MODIFICATION TO EXISTING SPRINKLER SYSTEM MUST BE PERFORMED BY LANDLORD'S APPROVED SPRINKLER CONTRACTOR, APPROVED BY LOCAL FIRE MARSHAL AND COORDINATED WITH MALL MANAGEMENT. COORDINATE WITH MALL'S APPROVED VENDOR'S ANY WORK THAT AFFECTS THE EXISTING ROOF, SPRINKLER SYSTEM, FIRE ALARM SYSTEM AND OTHER FIRE PROTECTION SYSTEMS BEFORE STARTING DEMOLITION, MAINTAIN OR REPAIR ANY FIRE RATED ASSEMBLIES AND SEPARATIONS INCLUDING BUT NOT LIMITED TO DEMISING WALLS, CEILINGS, FIRESTOPS AND FIRE RETARDANT TREATED BLOCKING. REPAIR ANY DAMAGE THAT OCCURS DURING DEMOLITION TO ANY SYSTEM OR ASSEMBLY THAT IS SLATED TO REMAIN, DO NOT ABANDON ANY UTILITIES OR MATERIALS WITHIN THE LEASE LINES - REMOVE SERVICES ETC. BACK TO SOURCE. ALL DEMOLISHED MATERIALS ARE TO BE REMOVED FROM THE SITE BY APPROVED METHODS. GENERAL CONSTRUCTION NOTES 1. REFER TO DEMOLITION PLAN(S) FOR EXTENT OF WORK TO BE PERFORMED IN THIS AREA PRIOR TO THE CONSTRUCTION OF NEW DEMISTING WALL. DEMOLITION MUST BE COMPLETE PARTICULARLY IN THOSE AREAS WHERE NEW CONSTRUCTION IS SCHEDULED TO BE PERFORMED. 2. INSPECT THE CONDITION OF EXISTING DEMISING PARTITIONS AND EXTERIOR GLAZING WALLS AND PROVIDE FULL HEIGHT AND FINISHED PARTITION TO UNDERSIDE OF DECK AS REQUIRED. PATCH AND REPAIR TO ACHIEVE OR MAINTAIN REQUIRED FIRE RATING - TAPE AND SPACKLE TO PREPARE FOR FINISHES. 3. UPON POSSESSION OF THE PREMISES, DIMENSIONS OF SPACE SHALL BE VERIFIED. G.C. SHALL SUBMIT NOTED DISCREPANCIES TO THE ARCHITECT WITHIN THREE DAYS OF THE START OF CONSTRUCTION. 4. WHEN RE -USING EXISTING DRYWALL CONSTRUCTION, PATCH AND REPAIR WALLS AS NECESSARY TO ENSURE REQUIRED RATING. PATCH ALL VOIDS INCLUDING DECK FLUTES WITH NON-COMBUSTIPLE MATERIALS. 5, REFER TO PARTITION SCHEDULE FOR WALL CONSTRUCTION 6. ALL DIMENSIONS ON PLAN FOR NEW INTERIOR LAYOUTS ARE FROM FINISHED WALL TO FINISHED WALL UNLESS NOTED OTHERWISE. 7. PATCH AND FIRESTOP GWB PARTITIONS AS REQUIRED BY LOCAL CODES 8. ALL PENETRATIONS OF FIRE RESISTIVE FLOORS OR SHAFT WALLS SHALL BE PROTECTED BY MATERIALS AND INSTALLATIONS DETAILS THAT CONFORM TO UL STANDARDS FOR THROUGH PENETRATIONS FIRE STOP SYSTEMS. THE CONTRACTOR SHALL SUBMIT SHOP DRAWING DETAILS WHICH SHOW COMPLETE CONFORMANCE TO THE UL LISTING TO THE ARCHITECT, SUCH DRAWINGS SHALL BE AVAILABLE TO ANY CITY INSPECTORS. THE DRAWINGS SHALL BE SPECIFIC FOR EACH PENETRATION WITH ALL VARIABLES DEFINED. WOOLPERT Architecture I Engineering I Geospatial 7635 Interactive Way Suite 100 Indianapolis, IN 46278 317.299.7500 WASHINGTON PRIME GROUP" 180 East Broad Street Columbus, OH 43215 washingtonprime.com x.40"' M. Arte a . G\STFR�9�� * AR 19600170 STATE OF j 0 (D w � W a V z � O � ~w z � z >= <U) � � U J J � i O U a � r . 0 J r_Yx� 1: Of i; � m O� v vJ r��•� Add 0,00 tY UJ N • O CO >. n J Z N O o, Q N Q M J SPACE A22D 9,329 SF YK�];�iT;�►I•I:� DEMOLITION & BARRICADES LANDLORD SHALL PROVIDE A TEMPORARY CONSTRUCTION BARRICADE PER MALL REQUIREMENTS, FULLY FINISHED, PAINTED AND READY TO RECEIVE TENANT'S GRAPHICS. LANDLORD SHALL DEMOLISH ALL PRIOR TENANT FIXTURES, FURNISHINGS AND EQUIPMENT. LANDLORD SHALL DEMOLISH THE EXISTING STOREFRONT AT THE NEW SLAB INFILL LOCATION ONLY. CONCRETE FLOOR SLAB LANDLORD SHALL PROVIDE A CONCRETE FLOOR SLAB IN COMPLIANCE WITH LOCAL AND FEDERAL CODES. LANDLORD SHALL RAISE THE LOWER SLAB -ON -GRADE APPROXIMATELY TWO FEET TO ALIGN WITH THE EXISTING HIGHER SLAB. THE VOID CAN BE FILLED WITH EITHER STONE/GRAVEL OR STRUCTURAL FOAM. LANDLORD SHALL INSTALL A NEW CONCRETE STEM WALL ON THE FRONT SIDE OF THE SLAB INFILL AS A SUPPORT FOR THE NEW STOREFRONT AND A BULKHEAD FOR THE SLAB. MASONRY LANDLORD SHALL FILL IN EXISTING REAR DOORS OR OPENINGS IN THE AREA OF THE SLAB INFILL ONLY. INTERIOR PARTITIONS & GYPSUM BOARD ON EXTERIOR WALLS INSTALL GREEN BOARD AT PERIMETER WALLS FOR NEW SLAB INFILL. EXISTING DEMISING WALLS TO REMAIN. STOREFRONT AND DOORS LANDLORD SHALL PROVIDE A NEW STOREFRONT AT THE LOCATION OF THE SLAB INFILL TO MATCH ADJACENT SPACE. ELECTRICAL LANDLORD SHALL PROVIDE ANY REQUIRED EMERGENCY LIGHTS. LANDLORD SHALL ADJUST/MODIFY ANY EXISTING ELECTRICAL COMPONENTS AS A RESULT OF THE SLAB INFILL. PLUMBING & SPRINKLER LANDLORD SHALL ADJUST SPRINKLER HEADS BY TURNING THEM UP TO MEET CODE. LANDLORD SHALL ADJUST SANITARY CONNECTION AS REQUIRED DUE TO SLAB INFILL. FIRE PROTECTION WORK NOTES FIRE PROTECTION SHALL BE PART OF THE MECHANICAL CONTRACT BY THE MALL APPROVED FIRE PROTECTION CONTRACTOR. AN EXISTING FIRE PROTECTION SYSTEM IS INSTALLED WITHIN THE PROPOSED LEASE SPACE. ADD PIPING AND HEADS AS REQUIRED TO ACCOMMODATE NEW PARTITIONS, CEILING HEIGHTS, AND HEAD TYPES. SPRINKLER HEADS IN FINISHED AREAS SHALL BE CHROME PLATED PENDANT TYPE. SPRINKLER HEADS IN BULKHEADS SHALL BE FULLY CONCEALED POP -OUT TYPE, VIKING A-1 OR EQUAL. PAINT TO MATCH CEILING. SPRINKLER HEADS IN UNFINISHED AREAS SHALL BE ROUGH BRASS PENDANT TYPE. SPRINKLER SUBCONTRACTOR SHALL INCLUDE LAYOUT DRAWINGS AND ALL REQUIRED MALL AND AGENCY APPROVALS AS PART OF THE WORK. ALL WORK SHALL CONFORM TO NFPA AS WELL AS ANY OTHER APPLICABLE CODES. PLANS MUST BE SUBMITTED WHICH VERIFY THAT THE FIRE SPRINKLER PROTECTION IS STILL ADEQUATE AFTER REMODEL, AND COMPLIES WITH UBC STANDARDS 38-1 (UBC 3801) AND OTHER APPLICABLE CODES AS A MINIMUM. SUBMIT SPRINKLER SYSTEM DRAWINGS AND SPECIFICATIONS. CONFIRM LOCATION OF LEASE LINE WITH LANDLORD PRIOR TO COMMENCING WITH DEMOLITION. COORDINATE WORK AND SCHEDULE WITH THE MALL MANAGEMENT OFFICE OR DESIGNATED LANDLORD REPRESENTATIVE. PROTECT ALL AREAS NOT INCLUDED IN THE WORK, ANY DAMAGE THAT OCCURS AS A RESULT OF THE WORK SHALL BE REPAIRED TO A LIKE NEW CONDITION. NOTIFY THE ARCHITECT AT ONCE OF ANY UNFORESEEN HAZARD BEFORE DEMOLITION IS COMPLETE. THE REMOVAL AND/OR HANDLING OF HAZARDOUS MATERIALS IS NOT PART OF WORK, IF ANY DISTURBANCE OF HAZARDOUS MATERIAL IS ANTICIPATED BY THIS WORK, AUTHORITIES MUST BE NOTIFIED AND PREDESCRIBED PROCEDURES MUST BE FOLLOWED. NO ALTERATIONS TO THE EXISTING STRUCTURAL MEMBERS ARE ALLOWED UNLESS SPECIFICALLY APPROVED IN WRITING BY THE LANDLORD. ALL CONDITIONS AND DIMENSIONS SHOWN ARE FOR REFERENCE ONLY AND MUST BE FIELD VERIFIED. UPON COMPLETION OF THE DEMOLITION ALL CONDITIONS AND DIMENSIONS ARE TO BE CHECKED FOR VARIANCES. REPORT ANY DISCREPANCY TO THE ARCHITECT, ANY UNREPORTED CONDITIONS WHICH MAY CONFLICT WITH THE PURPOSED NEW WORK AND MAY REQUIRE MODIFICATION, RELOCATION AND/OR REMOVAL SHALL BE IDENTIFIED AND REPORTED TO THE ARCHITECT FOR DETERMINATION OF BEST COURSE OF ACTION. REFER TO THE ARCHITECTURAL DRAWINGS FOR SCOPE OF NEW WORK AND TO CONFIRM TERMINATION AND / OR REMOVAL OF EXISTING FIXTURES, DEVICES AND SERVICES. ANY MODIFICATION TO EXISTING SPRINKLER SYSTEM MUST BE PERFORMED BY LANDLORD'S APPROVED SPRINKLER CONTRACTOR, APPROVED BY LOCAL FIRE MARSHAL AND COORDINATED WITH MALL MANAGEMENT. COORDINATE WITH MALL'S APPROVED VENDOR'S ANY WORK THAT AFFECTS THE EXISTING ROOF, SPRINKLER SYSTEM, FIRE ALARM SYSTEM AND OTHER FIRE PROTECTION SYSTEMS BEFORE STARTING DEMOLITION, MAINTAIN OR REPAIR ANY FIRE RATED ASSEMBLIES AND SEPARATIONS INCLUDING BUT NOT LIMITED TO DEMISING WALLS, CEILINGS, FIRESTOPS AND FIRE RETARDANT TREATED BLOCKING. REPAIR ANY DAMAGE THAT OCCURS DURING DEMOLITION TO ANY SYSTEM OR ASSEMBLY THAT IS SLATED TO REMAIN, DO NOT ABANDON ANY UTILITIES OR MATERIALS WITHIN THE LEASE LINES - REMOVE SERVICES ETC. BACK TO SOURCE. ALL DEMOLISHED MATERIALS ARE TO BE REMOVED FROM THE SITE BY APPROVED METHODS. GENERAL CONSTRUCTION NOTES 1. REFER TO DEMOLITION PLAN(S) FOR EXTENT OF WORK TO BE PERFORMED IN THIS AREA PRIOR TO THE CONSTRUCTION OF NEW DEMISTING WALL. DEMOLITION MUST BE COMPLETE PARTICULARLY IN THOSE AREAS WHERE NEW CONSTRUCTION IS SCHEDULED TO BE PERFORMED. 2. INSPECT THE CONDITION OF EXISTING DEMISING PARTITIONS AND EXTERIOR GLAZING WALLS AND PROVIDE FULL HEIGHT AND FINISHED PARTITION TO UNDERSIDE OF DECK AS REQUIRED. PATCH AND REPAIR TO ACHIEVE OR MAINTAIN REQUIRED FIRE RATING - TAPE AND SPACKLE TO PREPARE FOR FINISHES. 3. UPON POSSESSION OF THE PREMISES, DIMENSIONS OF SPACE SHALL BE VERIFIED. G.C. SHALL SUBMIT NOTED DISCREPANCIES TO THE ARCHITECT WITHIN THREE DAYS OF THE START OF CONSTRUCTION. 4. WHEN RE -USING EXISTING DRYWALL CONSTRUCTION, PATCH AND REPAIR WALLS AS NECESSARY TO ENSURE REQUIRED RATING. PATCH ALL VOIDS INCLUDING DECK FLUTES WITH NON-COMBUSTIPLE MATERIALS. 5, REFER TO PARTITION SCHEDULE FOR WALL CONSTRUCTION 6. ALL DIMENSIONS ON PLAN FOR NEW INTERIOR LAYOUTS ARE FROM FINISHED WALL TO FINISHED WALL UNLESS NOTED OTHERWISE. 7. PATCH AND FIRESTOP GWB PARTITIONS AS REQUIRED BY LOCAL CODES 8. ALL PENETRATIONS OF FIRE RESISTIVE FLOORS OR SHAFT WALLS SHALL BE PROTECTED BY MATERIALS AND INSTALLATIONS DETAILS THAT CONFORM TO UL STANDARDS FOR THROUGH PENETRATIONS FIRE STOP SYSTEMS. THE CONTRACTOR SHALL SUBMIT SHOP DRAWING DETAILS WHICH SHOW COMPLETE CONFORMANCE TO THE UL LISTING TO THE ARCHITECT, SUCH DRAWINGS SHALL BE AVAILABLE TO ANY CITY INSPECTORS. THE DRAWINGS SHALL BE SPECIFIC FOR EACH PENETRATION WITH ALL VARIABLES DEFINED. WOOLPERT Architecture I Engineering I Geospatial 7635 Interactive Way Suite 100 Indianapolis, IN 46278 317.299.7500 WASHINGTON PRIME GROUP" 180 East Broad Street Columbus, OH 43215 washingtonprime.com x.40"' M. Arte a . G\STFR�9�� * AR 19600170 STATE OF j 0 (D w � W a V z � O � ~w z � z >= <U) � � U J REV DATE DESCRIPTION 02/23/2017 PERMIT SET Pro= 077287 01/30/2017 Sheet Name: Sheet Name; PROJECT SPECIFICATIONS G-002 J � a O U Y J L.L m O� v vJ n CY) tY UJ N H O CO >. J Z N O o, Q N Q M J REV DATE DESCRIPTION 02/23/2017 PERMIT SET Pro= 077287 01/30/2017 Sheet Name: Sheet Name; PROJECT SPECIFICATIONS G-002