EXISTING METER PIT
3/4" CW
CD 6"CO
(IE 94'-6") — —�
6"CO
3 (4J C5 6
NEW METER PIT BY 7
OTHERS, METER BY MP 7 MPMP MP MP
UTILITY COMPANY Q OTQ Q
� I
t
I I
4"CO
4"CO
CO (IE 96'-6") v I I "' i 0 CO (IE 96'-6") i
I
GENERAL NOTES:
1.
CONTRACTOR SHALL CONTACT AND COORDINATE WITH ALL APPLICABLE UTILITIES, VERIFY AND BE RESPONSIBLE
GALLON
FOR ANY AND ALL FEES ASSOCIATED WITH INSTALLATION OF PLUMBING SYSTEMS.
2.
CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND EXISTING UTILITY SERVICE LOCATIONS PRIOR TO
MARK
COMMENCING WORK. NOTIFY CONSTRUCTION MANAGER OF ANY INCONSISTENCIES WITH THE PLANS AND
QTY; MANUFACTURER
SPECIFICATIONS.
3•
PLUMBING AND PIPING SYSTEMS SHALL BE INSTALLED COMPLETE PER ALL APPLICABLE STATE AND LOCAL
CAPACITY
CODES. ALL MATERIALS, FIXTURES, DEVICES SHALL BE SUBMITTED FOR APPROVAL TO ADMINISTRATIVE AUTHORITY
AMPS
AND SHALL CONFORM TO APPLICABLE STANDARDS AND BE FREE FROM DEFECTS PER INDIANA IPC 301.1.1.
NOTES
TEST SYSTEM PER 2012 IPC IAC 16-1.4
4.
UNDERSLAB SANITARY & STORM PIPING SHALL BE SCH. 40 PVC & PITCHED MINIMUM OF 1/8" PER FOOT.
VENT
WASTE, VENT, DRAIN PIPE SHALL COMPLY WITH 2012 IPC 675 IAC 16-1.4 701.0 TO 706.0
5.
WATER PIPING SHALL BE "L" HARD DRAWN COPPER PER 2012 IPC 16-1.4 604.0 TO 608.0
1 AMERICAN STANDARD
PIPING SIZED PER 2012 IPC 16-1.4
6.
TEST WATER SYSTEM UNDER 150 PSIG HYDROSTATIC PRESSURE FOR A MIN. OF 4 HOURS.
7.
PROVIDE CLEANOUTS AT ENDS OF ALL HORZ. RUNS AND AT BASE OF VERTICAL WASTE STACKS. CLEANOUTS SAME SIZE AS PIPE
1-1/2'
THEY SERVE. PROVIDE SUITABLE WALL OR FLOOR CLEANOUT AND COVER APPROPRIATE FOR THE SUBSTRATE
8.
ALL STORM DRAIN FIXTURES, LEADERS AND PIPING SHALL BE SIZED AND INSTALLED PER STATE CODE 2012 IPC IAC 16-14.1
(OR APPROVED EQUAL)
CHAPTER 11
9.
PROVIDE SCH. 40 BLACK PIPE, GAS VALVE, UNION AND DRIP LEG FOR ALL NEW GAS FIRED EQUIPMENT. INSTALL PER NFPA-54
-
& LOCAL CODES. NEW GAS PIPE ON ROOF SHALL BE SUPPORTED ON MANUFACTURED PIPE SUPPORTS.
10,
COORDINATE HVAC ELECTRICAL REQUIREMENTS \AITH ELECTRICAL CONTRACTOR PRIOR TO ORDERING EQUIP. OR INSTALLATION.
-
VERIFY VOLTAGE AND PHASE PRIOR TO ORDERING EQUIPMENT.
11.
PROVIDE RETURN AIR DUCT SMOKE DETECTION DEVICE IN HVAC UNITS OVER 2000 CFM.
PLAN KEY NOTES:
OCONTINUATION OF PIPING AFTER CLEANOUT BY SITE UTILITIES CONTRACTOR.
2O 4" HUB DRAIN AND TRAP AT SPRINKLER RISER, COORDINATED EXACT LOCATION WITH SPRINKLER CONTRACTOR.
OPROVIDE LOOSE THERMOSTAT WITH 100' LOOPED WIRE FOR FUTURE TENANT. INSULATED SA/RA DROP FROM CURB
GAS METER BANK. COORDINATE EXACT LOCATION ON WALL WITH UTILITY.
1" LOW PRESSURE (6"-19") PIPING FROM METER UP WALL CAVITY TO EACH ROOFTOP HVAC UNIT.
5O 4" VERTICAL STORM LEADER DOWN COLUMN, TIE—IN TO UNDERGROUND STORM MAIN. SEE DETAIL THIS SHEET.
O4" SANITARY AND GREASE WASTE LATERAL STUB UP TO GRADE WITH CAP FOR EACH FUTURE TENANT
ODOMESTIC WATER METER PIT. P.C. TO PROVIDE PIT, METER YOKE AND 1" WATER STUB IN FOR EACH FUTURE TENANT.
WATER HEATER SCHEDULE
PLUMBING FIXTURE SCHEDULE
TYPE
GALLON
RECOVEPY
HEATING
DELTA "T"
MARK
ADA
QTY; MANUFACTURER
MODELM
DESCRIPTION
TRIM PACKAGE
CAPACITY
ROUGH -IN
AMPS
REMARKS:
NOTES
CW
HW
WASTE
VENT
MOUNTINGHEIGHT
PIH
NO
1 AMERICAN STANDARD
-
LAVATORY, WALL MOUNTED
AMERICAN STANDARD - COLONY
SOFT - 02175.SO4
1/2"
7/2"
1-1/2'
1-1/2"
34 70 RIMADULT,
WALL CARRIER
(OR APPROVED EQUAL)
P2H
NO
1 AMERICAN STANDARD
-
TANK -STYLE WATER CLOSET, WHITE, ELONGATED TOILET,
LOW CONSUMPTION
N/A
1/2'
-
4'
2"
16.5" TO RIM
ADULT, 1.28 GAL/FLUSH, GRAVITY FLUSH,
PROVIDE SEAT
(OR APPROVED EQUAL)
NOTES:
PLAN KEY NOTES:
OCONTINUATION OF PIPING AFTER CLEANOUT BY SITE UTILITIES CONTRACTOR.
2O 4" HUB DRAIN AND TRAP AT SPRINKLER RISER, COORDINATED EXACT LOCATION WITH SPRINKLER CONTRACTOR.
OPROVIDE LOOSE THERMOSTAT WITH 100' LOOPED WIRE FOR FUTURE TENANT. INSULATED SA/RA DROP FROM CURB
GAS METER BANK. COORDINATE EXACT LOCATION ON WALL WITH UTILITY.
1" LOW PRESSURE (6"-19") PIPING FROM METER UP WALL CAVITY TO EACH ROOFTOP HVAC UNIT.
5O 4" VERTICAL STORM LEADER DOWN COLUMN, TIE—IN TO UNDERGROUND STORM MAIN. SEE DETAIL THIS SHEET.
O4" SANITARY AND GREASE WASTE LATERAL STUB UP TO GRADE WITH CAP FOR EACH FUTURE TENANT
ODOMESTIC WATER METER PIT. P.C. TO PROVIDE PIT, METER YOKE AND 1" WATER STUB IN FOR EACH FUTURE TENANT.
WATER HEATER SCHEDULE
MARK
TYPE
GALLON
RECOVEPY
HEATING
DELTA "T"
VOLT/PHASE
REMARKS
CAPACITY
GPH
CAPACITY
'F
AMPS
WH -2
ELEC
I N STAHOT
--
3.5 KW
90
120/1
0.5 GPM, 1/2" HW/CW CONN.
LOCATED UNDER P2H (SINK)
J L 3"VTR
2"
TYPICAL TOILET
METER OR AS INDICT
BY
'OKE/SHUT-OFF/CI'
ASSEMBLY BY
1 " K-COPI
TAP BY PC TO CITY I
❑ O
0
rnon (' -z
T LID W/EXP. RING
'ROVED BY CITY
1 " K -COPPER
INCOMING WATER SERVICE DETAIL
T C�
P
TANK& PIPING CONTRACTORS, INC.
350 Gradle Drive
P.O. Box 3160 • Carmel,IN 46032
PH 317-846-4768
FAX 317-846-4788
HOOSIER AAA, SUITE #105
CLASSIC CLEANER, SUITE #106
1438 WEST MAIN STREET
CARMEL, INDIANA 46032
PLUMBING PLAN
PROJECT NO.:
DATE: 05/04/2017
SCALE:1 /8"=1 '-0"
DRAWN: JS
CHECKED: TW
P=l