Loading...
HomeMy WebLinkAbout03100149.16EXIT/ SERVICE ENTRY SYMBOLS LIST ® SUPPLY AIR DIFFUSER O DRAWING NOTE zRETURN AIR GRILLE (RE615TER) 511 CUBIC FEET PER MINUTE (CFM) ® EXHAUST AIR GRILLE (RE615TER) r},i SANITARY PIPE 1311 FLEXIBLE DUGTWORK -----sj VENT PIPE (SAME SIZE AS THERM05TAT 1111 " DIFFUSER NECK SUPPLY AIR DIFFUSER 4-- — --� GOLD WATER PIPE I�rt REVERSE ACTIN& THERM05TAT 4-- — — --� HOT WATER PIPE 'E vv SIZE) MAXIMUM 8'-0" WITH (24"x24" MODULE) PERMIT, L.L. RVIEA # SID DATE VOLUME DAMPER ` r ` BALL VALVE NOTED ON PLANS CARMEL, IN 0--� PIPE UP —+� DIRECTION OF AIR FLOW FLEXIBLE DUCT CONNECTED #0382 INDICATED ON PLANS. TO ELBOW. CONNECT WITH TO C—� PIPE DOWN Z CONNECT TO EXISTIN6 SYMBOL MINIMUM 6 SGREWS (EVERY (o0°) BUFFL.Y UNION DI US Y UNDERCUT DOOR DIFFUSER NECK DUGT51 ZE CONNECTION RING DIAMETER (INCHES b"-200¢ TOTAL AIR QUANTITY 511 511 GUBIG FEET PER MINUTE (GFM) PROVIDE 90 ° ELBOW (o,1 r},i (ADJUSTABLE) ON TOP OF 1311 FLEXIBLE DUGTWORK DIFFUSER CONNECTION NECK 1111 (SAME SIZE AS 811 1111 " DIFFUSER NECK SUPPLY AIR DIFFUSER 4 SIZE) MAXIMUM 8'-0" WITH (24"x24" MODULE) PERMIT, L.L. RVIEA # SID DATE UNLESS OTHERWISE lin ne NOTED ON PLANS CARMEL, IN AIR PATTERN FLOW. FLOW HVAC PLAN ANDNOTE5 SHALL BE 4 WAY UNLESS FLEXIBLE DUCT CONNECTED #0382 INDICATED ON PLANS. TO ELBOW. CONNECT WITH TO #332 I" METAL BAND AND PROVIDE MINIMUM 6 SGREWS (EVERY (o0°) BUFFL.Y Alii DI US Y NO SCALE 1�i G A�lIGA1. �=L CCR FLAN SCALE: 1/5' I'-0" rn;p bwlkIl,"� Sien-r;= C=� OI OUTLINE OF EX 1 STING LANDLORD PROV I DED ROOF MOUNTED 6A5 FIRED HVAG UNIT WITH ROOF CURB, ECONOMIZER AND RELIEF. O EXI5TIN6 FULL 51ZE SUPPLY AND RETURN AIR DUCTS UP TO ROOF MOUNTED HVAC: UNIT. O3 EXI5TIN6 SUPPLY AIR DUGTWORK MOUNTED TIGHT TO STRUCTURE. CONTRACTOR SHALL PROVIDE OFFSETS (MAXIMUM 30 DEGREE ANGLE) TO MAINTAIN DUGTWORK HIGH AS P0551 BLE. O EXI5TIN6 EXHAUST AIR DUGTWORK MOUNTED. TIGHT TO STRUCTURE. O EXI5TIN6 AIR DEVICE TO BE REMOVED. OEXI5TIN6 DUCT MOUNTED SMOKE DETECTOR (TYPIGAL). PROVIDE A MINIMUM 12" x 12" DUCT AGGE55 DOOR FOR DETECTOR TUBE INSPECTION. ON DUCTS OVER 3611 WIDE, PROVIDE TWO ACCESS DOORS. OEXISTIN6 SUPPLY AIR REGISTER MOUNTED ON 51DE OF DUCT OR AT EDGE OF GEILIN6 BULKHEAD. ALL DIFFUSER BLADES SHALL BE ADJUSTED TO PROVIDE EQUAL AIR DISTRIBUTION DOWN TO FLOOR. F I NAL COORD I NAT I ON/APPROVAL BY ARCHITECT (TYPICAL). O8 EXI5TIN6 SUPPLY AIR DIFFUSER WITH 24"x2411 MODULE AND TRM PLASTER FRAME (TYP.). O EXI5TIN6 SUPPLY AIR DIFFUSER WITH 12"x12" MODULE AND TRM PLASTER FRAME (TYP.). 10 EXI5TIN6 THERMOSTAT MOUNTED ON WALL fbO" A.F.F. WITH LOCKABLE COVER. COVER SHALL BE METAL AND PAINTED A5 DIRECTED BY ARCHITECT (TYPICAL). II EXI5TIN6 BALANGIN6 DAMPER (TYP). 12 EXI5TIN6 EXHAUST DUCT UP TO GOOSENECK. 13 EX15TINO EXHAUST FAN SUSPENDED FROM STRUCTURE AND INTERLOCKED WITH L 16HT SW I TGH BY THE ELECTRICAL CONTRACTOR. N07 1 CF TO C0N7RAC70R5 : ALL CONTRACTORS PRIOR TO BID SUBMISSION PROCESS SHALL VISIT PROPOSED WORK 51TE AND FIELD VERIFY ALL EXISTIN6 CONDITIONS. ANY GONDITIONS THAT DIFFERS FROM THAT SHOWN ON THIS PLAN SHALL BE REPORTED TO ARGHITEGT/ENGINEER 50 THAT NEW AND REVISED BID DRAWIN65 OR INFORMATION MAY BE ISSUED. MODIFIGATIONS TO SCOPE OF WORK WHICH RESULTS FROM CONTRACTORS NE:6LEGT TO VISIT THE 51TE PRIOR TO SUBMITTING BID, SHALL BE THIS GONTRACTORS SOLE RESPONSIBILITY. 14 EXI5TIN6 THERMOSTAT MOUNTED ON WALL/MILLWORK PANEL (TYP.). 15 EXISTING FLEXIBLE DUCT CONNECTION (TYP.). I6 EXI5TIN6 LINED RETURN AIR DUCT WITH FULL SIZE ELBOW. PROVIDE A 1/2" x 1/2" WIRE MESH ON END OF DUGT/ELBOW TO KEEP OUT DEBRIS FROM GEILIN6 PLENUM. 17 EXISTING I" DOOR UNDERCUT. COORDINATE WITH ARCHITECT. IB EXI5TIN6 SUPPLY AIR RE615TER MOUNTED IN BOTTOM OF DUCT. Iq EXISTING AIRTITE FITTING WITH DAMPER AND ADHESIVE 6A5KET. ® EXISTING AIR DEVICE TO BE REMOVED AND RELOCATED. 21 EXISTING CARRIER MODEL ZD -6 El EGTRONIG SLAVE DAMPER. © EXI5TIN6 DUCT MOUNTED "TYPE B" FIRE DAMPER. ©3 EXI5TIN6 12"x12" RETURN AIR GRILLE WITH TRM PANEL. ® EXISTIN6 GEILIN6 MOUNTED AIR CURTAIN W/ ELECTRIC HEAT. CURTAIN SHALL BE MARS MODEL 72G WITH 12 KW ELECTRIC HEAT, (2) 1/2 HP MOTORS, 3400 GFM ® 2275 FPM, 140 LBS, 480\1/3 PHASE, 15 AMPS. EXISTING DUGTWORK TO BE REMOVED. EX15TINO DUGTWORK TO BE GAPPED AND SEALED. RELOCATED AIR DEVICE. ® RELOCATED THERMOSTAT. 36"x12" AIR TRANSFER GRILLE WITH F.D. IN WALL. ® 36"x12" AIR TRANSFER GRILLE. MOUNT GRILLES ON BOTH SIDES AND INSTALL BLADES UPWARD TO AVOID LI&HT TRANSFER. 31 SUPPLY AIR DIFFUSER WITH 12"x12" MODULE AND TRM PLASTER FRAME (TYP.). © THERMOSTAT MOUNTED ON WALL t60" A.F.F. WITH LOCKABLE COVER. COVER SHALL BE METAL AND PAINTED AS DIRECTED BY ARCHITECT (TYPICAL). ®3 THERM05TAT MOUNTED ON WALL/MILLWORK PANEL (TYP). ®4 LINED RETURN AIR DUCT WITH FULL 51ZE ELBOW. PROVIDE A 1/2" x 1/2" WIRE MESH ON END OF DUGT/ELBOW TO KEEP OUT DEBRIS FROM GEILIN6 PLENUM. 35 DUCT MOUNTED "Tl'PE B" FIRE DAMPER. 206/ METAL GONNE STRUG SUPPL DUCT OPPO� DANA=LI— SUi�PLY NO SCALE DOUBLE DEFLECTION SUPPLY A I R RE615TER SHEET METAL COLLAR WITH INSIDE FLANGE AND I" SOUND L I N I N6 ,41R RESISTER =�ETAIL AIR TITS FITTING. PROVIDE SGREWS IN EACH PRE -PUNCHED SGREW HOLES IN CONNECTION RING TO SUPPORT F I TTI N6 LOW PRE55URE - SUPPLY AIRDUGT 1/8" NEOPRENE 6A5KET BALANG I N6 DAMPER - FLEXIBLE INSULATED DUCTWORK (MAXIMUM 81-019 FLEXIBLE DUCT CONNECTED TO AIR TITE. CONNECT WITH I" METAL BAND AND PROVIDE MINIMUM 6 SGREWS (EVERY 60°) AIR TITS SITTING I7E7AIL NO SCALE Alii TITS 51ZE Ci1lllll4AR7 DUGT51 ZE CONNECTION RING DUGT51 ZE CONNECTION RING 511 511 3000 HK*HWAY 314 SUITE IM ORAPEVPK TEXAS 79061 1211 (o,1 r},i loll 1311 711 1011 1111 1511 811 1111 12" 1111 NOTE: 1) WHERE CONNECTION RING 51ZE 15 LARGER THAN SUPPLY DUCT, THEN CONNECTION RING SHALL BE CRIMPED OVER DUCT AND CONNECTED, SCREWED 4 SEALED ON TOP AND BOTTOM OF SUPPLY DUCT. 20 6AU6E X I" METAL STRAP CONNECTED TO STRUCTURE ABOVE (TYPICAL) THRU BOLT INSULATION ROUND DUC MAX. 5A6 1/2" PER FOOT OF SUPPORT SPAG I N6. 7 -LEX I BLE DUCT RJN-OUT SJFFOR7 DETA I L NO SCALE NOTES: 1) FLEXIBLE DUCT SHOULD EXTEND 5TRA16HT FOR SEVERAL INGHES FROM REGTAN6ULAR DUCT CONNECTION BEFORE BENDIN6. 2) FLEXIBLE DUCT SHOULD NOT EXCEED 6-O" IN LENGTH. U5E RI61D ROUND DUGTWORK WHEN RUNOUTS EXCEED 61-011. dzi O 4 8 16 24 m 5GALE:1/8"= I' -O" AM 1/®M DWA1'NE A. MANN, ARCHITEC 3801 5 CAPITAL OF TEXAS Hi SUITE 550 AUSTIN TX ?870, TEL: 512."112.'1"1"14 FAX: 512."112.7"1"15 DON PENN CONSULTING ENGINEER 3000 HK*HWAY 314 SUITE IM ORAPEVPK TEXAS 79061 89-410400 FAX W-26NMIl 2$m 9. PE196005 TE OF SS/pti� a1 1/ 06.26.03 PERMIT, L.L. RVIEA # SID DATE 155UED FOR lin ne MERCHANT'S SQUARE CARMEL, IN SPACE #R� HVAC PLAN ANDNOTE5 MAMA #0382 FINL STORE #332 C