HomeMy WebLinkAbout03110049.8— --- L S ------- -- —--- 2'—O// To face of chair base suction seperetor, developing tank/processor, gas s air valves and nitrous oridI-/ oxygen valves. Manufacturer's specification templates for all dental eouic,rrent Nil[ be prodded by the Potterson Dental Suoply representative. The representative will also supervise the location of said templates. DENTAL UNIT – Install 1/2" FAPT cola Hater, 1/2" 'APT air (and 1-1/2" waste and/ ;D.i.i.i or 5/8" OD suction, ONLY WHERE SPECIFIED') pipes above finished floor or out from, gall. See ,nor.ufacturer's specification, template for positioning. These dimensions are CRITICAL and must comply ,with measurements of manufacturer's templates. Adopters and valves, where indicated, must be rigidly conformed to. Install acc- essible woter & air salves for each unit. Provide Nater pressure regulator, if the pressure exceeds 150 PSI. AIR COMPRESSOR – Starting f-om air compressor location, run 1/2" copper air ( �. fine dna tee off to dPntai units and all other areas that require air. Reduce the size of line to conform to manufacturer's specifications. (Example: Dental units, well outlets, etc.) Compressor air intake shall be from outside building, if practical, or shall be stored in location with neither vocuum system discharge or chemical based materiai storage. Compressor supplied by doctor and connected by plumber. See compressor mcinufacture•' s specifications for pre–installation details. p AIR OUTLET – Redu.e to 3/8" FPT flange flush with +raft. Comply with man,ufoct– urer's valve adaptation to line. install 44" aoove floor jq GAS OUTLET – Some specifications as air outlet for gas outlet_ Q DEVELOPING TANK – Recess tank.. into counter top. Supply woste with trap 12" above floor. Run hot and cold water lines to Thermostatic Mixing Valve 60" above floor. Rur: tempered nater line from thermostatic mixing valve to bottom of developing tank. All exposed piping, above counter top, to be chrome. Doctor to Drovide Thermostatic Mixing Valve and Developing Tank, plumber to install. See manufacturer's specifications for rough–in. MODULAR CABINET SINK AND SINGLE LEVER FAUCET – install waste, hot and cold water lines 18" above floor. Supplied by doctor and installed by plumber. I LAB & STERILIZATION SINKS & FAUCETS – Supplied and installed by the plumber. L S `, Install rough–in lines at 18" above floor. 3 PLASTER TRAP – Install for lab sink and model trimmer. Supplied by the doctor P T - and installed by plumber. Brace trap to support .weight of full trap and to simplify the removal of connister for cleaning. IAODEL TRIMMER – Install cold Ovate line :with a 1/4" chrome angle stop above the iA T counter top. Model trimmer has a 1" male nipple for flexible waste pipe connection. Plumber to run waste line from tr'mmer to sink tailpipe/plaster trap with tee into sink strainer tailpiece connection. Provided by doctor and installed by plumber. SO SUCTION OUTLET – Incorporated into dental unit plumbing ("D.U.") as designated on pian. Reduce riser to 5/8" O.D. through floor (or wall) with 1" stub out. SD SUCTION UNIT – DRY SYSTEM – Run 2" Main line in rigid copper or 3 schadule 40 PVC piping (80 ps minimum) reduce to 3/4" below and through the floor, or wail, in the treatment rooms, as indicated on the plan. At power unit terminate 2" main line with o 2" FPT fit– ting. Plumber to install 45's and avoid 90 degree angles, where possible. See Manufacturer's specifications. #2 DRAIN – Vented drain reduced to 3/4" to be provided in EACH TREATMENT ROOM, at suction outlet, at 6" above the floor. #3 EXTERNAL VENT – For exhaust air – Plumber to install external vent. Exhaust shall be located remote from any door, window, intake or discharge. Follow manufacturer's specifications for installation. -u4 WATER – Provide e valved 1/2" FPT cold water line within 3' of suction unit. rr COMMODE – Plumber to supply and install quiet flush commode. Color to be 0 selected by doctor. Handicapped fixtures and tail to be supplied for handicapped designated restroom. VANITY SINK – Plumber to supply and install vanity cabinet, sink and faucet, where designated. Handicapped fixtures to be supplied for handicapped designated restroom. THESE DIAGRAMS ARE NOT AN ARCHITECTURAL PLAN. THESE OIAGR.'.MS ARE NOTORAYM TO ARCHITECTURAL SCALE. NOR DO THEY INCLUDE ALL OF THE REQUIREMENTS THAT MAY REQUIRED FOR AN ARCHITECT TO PROVIDE YOU MATH COMPLETE ARCHITECTURAL PLANS. PATTERSON'S DIAGRAMS MAY NOT BE SUBMITTED AS FINISHED ARCHITECTURAL. DRAMANGS FOR THE PURPOSE OF OBTAINING A BUILDING PERMIT. IF YOU SHOULD CHOOSE TO USE PATTERSON's DIAGRAM IN THE PLACEMENT OF YOU EQUIPMENT. YOU SHOULD RETAIN A: REGISTERED ARCHITECT TO CONVERT THE DIAGRAM INTO PROPER AND COMPLETE ARCHITECTURAL PLANS. PATTERSON 'NILL WORK WITH THE ARCHITECT YOU SELECT TO DEVELOP C01.11PLETE ARCHITECTURAL PLANS. Z Orr V^^! 00 -C'\ f I I 0 00� 7 7v ~ o0 l 0 o0oo 00 Cl.r N >— ^' V7 CIO Drawn By: ear. � raY? Z aFin ��Q >: a=xe ZDO =car 0 U V) 0LJ � d Z.m N a Q W X Z Q w Q a 3 V z a I- @ Z� 00 p ~ 7Jw� z o�a�s�D O ZZ Z 2 2 0 W WNwU ¢ tnmQ w< SN0`�� CL :DZUa W 0wd < w o�ZX 0X�g Z_j ��0 (rM _� a�ZD o0ow EQ wr� L41 5Z w� w.0m0 w�U �'oa a Z.Q IXW <W JN WO Wy V U afi �ila1-40 0 W U Ld>. J.N- Ir0� Y = <0P:In <,00ED 0 va U z w"Fj5.o Q;= y O aa20z W� alma o m– z Nn�vvjNo� M< 0 Z U N-7 ��+dfTf'a OU 0W X Za 40¢ W Q W aCX � Z 0 U U d O <W LLWZ 250 �ZC, 6 Ixa0 o�0�'WaZowUU< oa: =ww� �Qi=IQ f� a� a,> a� W DATE: 07/31/03 DWG.: Lund -00 REVISED DATE: Q Q 4 of 5. I N