HomeMy WebLinkAbout03070201.3POWER & COMMUNICATIONS PLAN 3/A1.1 1/8' =1'-V Ie..11 ■ 0 ELECTRICAL LEGEND NOT ALL MAY APPLY. REFER TO ELECTRICAL PLAN FOR ADDITIONAL NOTES AND ELECTRICAL INFO. p BUILDING STANDARD FLOOR MOUNTED R INDICATES EXISTING ITEM TO BE RE - MANUFACTURER DUPLEX ELECTRICAL OUTLET. FLUORESCENT LIGHT FIXTURE LOCATED. ALL OTHER OUTLETS SHOWN NUMBER / COLOR REMARKS NO. ARE TO BE NEW. SEE NOTE BELOW. ® BUILDING STANDARD FLOOR MOUNTED WALL MOUNTED LIGHT SWITCH. COVER INDICATES NEW ITEM LOCATION REFER TO INDEX SHEET FOR TYPICAL WALL TYPES WALLS TO DECK, RATED WALLS, ETC AND ADDITIONAL ) DATA AND OR TELEPHONE LINE N AS SHOWN. SEE NOTE BELOW. PLATE COLOR TO MATCH EXISTING OUTLET. WALL -TO -CEILING DESIGN CONDITIONS AND CONSIDERATIONS. 100 RECEPTION / WAITING CPT -1 ADJACENT COVER PLATES. ("3" DENOTES INDICATES GROUND FAULT INTERRUPT C) BUILDING STANDARD ELECTRICAL GFI OUTLET. BUILDING STANDARD 2X2 JUNCTION BOX. -WAY SWITCH.) ("D" DENOTES DIMMER 2 PROVIDE NIGHT LIGHT CIRCUITS AS REQUIRED; G.C. TO COORDINATE WITH ELEC. ENGINEER. BROADLOOM CARPET VINYL COMPOSITION TILE Fil IRECT CONNECTIONFOR =0 BUILDING STANDARD WALL MOUNTED SWITCH.) ADND COMMUNICATIONS FOARIONSTEEMSPOWER CEILING GRID AND TILE SHALL BE BUILDING STANDARD. DUPLEX OUTLET. SEE TYP 2X4 NOTES ABOVE. FURNITURE PANELS. =0 220 220 OUTLET wmOwl ACT -1 -- BUILDING STANDARD 2X4 PP INDICATES POWER POLE LOCATION. 12"x12" TILE BUILDING STANDARD WALL MOUNTED LAN RM VCT -1 FLUORESCENT LIGHT FIXTURE FOUR-PLEX ELECTRKAL OUTLET. OTHERWISE NOTED) P-1 THAT DIFFER FROM WHAT IS SHOWN ON THESE PLANS. 9'-0" (1) THERMOSTAT -- BUILDING STANDARD WALL MOUNTED SIZES OF MECHANICAL EQUIPMENT (IF SHOWN HERE) ARE SHOWN FOR REFERENCE ONLY. COORDINATE RESILIENT BASE JOHNSONITE DEDICATED DUPLEX OUTLET. SPEAKER ACTUAL SIZES WITH MECHANICAL ENGINEER. _ _ --- -- - 103 SPECIAL MOUNTING HEIGHT INDICATION b WALL MOUNTED TELEPHONE AND +42" FOR WALL. OUTLETS. TAKEN TO EXISTING CEILING GRID TO REMAIN. OR DATA LINE SHARED OUTLET. BUILDING STANDARD ILLUMINATED EXIT LIGHT BOTTOM OF PLATE. FOR REFERENCE ONLY. COORDINATE ACTUAL SIZES WITH ELECTRICAL ENGINEER. "PLUG MOLD" POWER STRIP (RE: NOTE: UNLESS NOTED WITH AN "R" OR AN "N' SOLID DENOTES DIRECTION OF FACEPLATE. KEYED NOTES). ALL ITEMS WILL BE EXISTING TO REMAIN. 1/8' =1'-V Ie..11 ■ 0 �: CEILING LEGEND WALLS REFLECTED CEILING PLAN GENERAL NOTES MILLWORK BUILDING STANDARD 2X4 NOT ALL MAY APPLY. -77011 NOT ALL MAY APPLY. REFER TO REEL. CEILING PLAN FOR ADDITIONAL NOTES AND CEILING INFO. MANUFACTURER PATTERN FLUORESCENT LIGHT FIXTURE 3'-0" x NUMBER / COLOR REMARKS NO. NAME THREE$ LAMP ELECTRONIC BALLAST BASE WALL MOUNTED LIGHT SWITCH. COVER 1. REFER TO INDEX SHEET FOR TYPICAL WALL TYPES WALLS TO DECK, RATED WALLS, ETC AND ADDITIONAL ) WEST 18 C CELL PARABOLIC FIXTURE $3 PLATE COLOR TO MATCH EXISTING CTR. TOP WALL -TO -CEILING DESIGN CONDITIONS AND CONSIDERATIONS. 100 RECEPTION / WAITING CPT -1 ADJACENT COVER PLATES. ("3" DENOTES P-1 P-5 P-1 P-2 9'-0' BUILDING STANDARD 2X2 $� 3 -WAY SWITCH.) ("D" DENOTES DIMMER 2 PROVIDE NIGHT LIGHT CIRCUITS AS REQUIRED; G.C. TO COORDINATE WITH ELEC. ENGINEER. BROADLOOM CARPET VINYL COMPOSITION TILE Fil SNEAK PREVIEW, 2690 MULTICOLOR STD EXCELON FLUORESCENT LIGHT FIXTURE 26 OZ., DENSE PATTERENED LOOP SWITCH.) 3. CEILING GRID AND TILE SHALL BE BUILDING STANDARD. B-1 SEE TYP 2X4 NOTES ABOVE. P-1 P-1 4. wmOwl ACT -1 -- BUILDING STANDARD 2X4 0 SPRINKLER HEAD (EXISTING UNLESS 12"x12" TILE AND/OR PENETRATIONS. COORDINATE WITH ARCHITECT ANY FIELD VERIFIED OR AS -BUILT CONDITIONS LAN RM VCT -1 FLUORESCENT LIGHT FIXTURE P-1 OTHERWISE NOTED) P-1 THAT DIFFER FROM WHAT IS SHOWN ON THESE PLANS. 9'-0" ON NIGHT LIGHT CIRCUIT (U.O.N.) -- -- 5. SIZES OF MECHANICAL EQUIPMENT (IF SHOWN HERE) ARE SHOWN FOR REFERENCE ONLY. COORDINATE RESILIENT BASE JOHNSONITE O SPEAKER ACTUAL SIZES WITH MECHANICAL ENGINEER. _ _ --- -- - 103 OFFICE CPT -1 6. SIZES AND SHAPES OF LIGHTING AND OTHER MISC ELECTRICAL EQUIPMENT (IF SHOWN HERE) ARE SHOWN -" -- -- -- EXISTING CEILING GRID TO REMAIN. P-2 BUILDING STANDARD ILLUMINATED EXIT LIGHT ACT -1 FOR REFERENCE ONLY. COORDINATE ACTUAL SIZES WITH ELECTRICAL ENGINEER. ' - `C7 SOLID DENOTES DIRECTION OF FACEPLATE. SHERWIN WILLIAMS -- -- FLAT FINISH 104 OFFICE 7 UNLESS OTHERWISE NOTED INSTALL SUSPENDED CEILING GRID WITH EQUAL SIZE PANELS AT EACH SIDE P-1 P-1 P-1 P-2 9'-0' OR ENDS OF ROOMS. NO PANELS SHOULD BE LESS THAN 1'-0" WIDE. -- -- - P-2 P-3 PAINT EMERGENCY LIGHT FIXTURE W/ EMERGENCY EXIT LIGHTING PACK & BATTERY BACK UP. 8, �.•.� FLAT FINISH FLAT FINISH o v BREAK RM �i�iii®i B-1 P-1 INDICATES NEW CEILING GRID TO BE ••• P-1 9'-0" CENTERED IN CEILING PANELS. MW PL -1 - INSTALLED. SHERWIN WILLIAMS "E" INCICATES EXISTING TO REMAIN. 9• WHERE EXISTING CEILING GRID IS REMODELED TO MEET NEW CONSTRUCTION THE CONTRACTOR SHALL: OPEN OFFICE CPT -1 B-1 P-1 P-1 "R" INCICATES EXISTING TO BE RELOCATED. P-1 A. REPLACE ALL DAMAGED OR UNREPAIRABLE PORTIONS OF EXISTING GRID WITH NEW GRID TO ACT -1 -- INDICATES NEW GYPSUM BOARD - UNLESS NOTED WITH AN "E" OR AN "R" ALL PAINT MATCH EXISTING BUILDING STANDARDS. -- BULKHEAD TO BE INSTALLED. SW6674, "JONQUIL" ITEMS SHOWN WILL BE NEW. 107 B. REMOVE PORTIONS OF EXISTING GRID OR PROVIDE NEW GRID AS REQUIRED BY NEW CONSTRUCTION. CPT -1 B-1 P-1 P-4 P-1 ALL NEW GRID MUST MATCH EXISTING TO REMAIN, OR BE BUILDING STANDARD. 9'-0" NEW INCANDESCENT DOWNLIGHT. -- -- - C. REPLACE ALL DAMAGED CEILING TILES WI1H NEW TILES TO MATCH EXISTING TO REMAIN, OR PAINT SHERWIN WILLIAMS -- SW6594, "POINSETTIA" 108 TO MATCH EXISTING BUILDING STANDARDS. CPT -1 B-1 -- P-1 -- P-1 9'-0" ACT -1 -- -- - PAINT SHERWIN WILLIAMS -- SW6544, "MESMERIZE" 109 STORAGE CPT -1 B-1 P-1 P-1 P-1 P-1 9'-0' ACT -1 -- -- - PLASTIC LAMINATE FORMICA -- 7711-58, "METALLIC GAUZE" ACOUSTICAL CEILING TILE ARMSTRONG GEORGIAN 2x2 WHITE USE WITH BUILDING STANDARD GRID SYSTEM. W/ BRITE CHROME WIRE PULLS MW MILLWORK MERILLAT AVIA WHITE REFLECTED CEILING PLAN GENERAL ELECTRICAL NOTES NOT ALL MAY APPLY. REFER TO ELECTRICAL PLAN FOR ADDITIONAL NOTES AND ELECTRICAL INFO. 1. THIS DRAWING IS INTENDED TO PROVIDE INFORMATION RELATING TO THE LOCATION OF WIRING DEVICES AND OUTLETS ONLY. IT IS THE RESPONSIBILITY OF THE ELECTRICAL DESIGN/BUILD CONTRACTOR TO PROVIDE NECESSARY DOCUMENTS RELATING TO THE ACTUAL ELECTRICAL INSTALLATION AND TO INSTALL ALL WIRING DEVICES IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES. 2. ALL DIMENSIONS ARE FROM FINISHED WALL SURFACE OR COLUMN CENTERLINE TO CENTERLINE OF OUTLETS OR CENTERLINE OF PAIRS OF OUTLETS. 3. ALL WALL MOUNTED WIRING DEVICES AND RECEPTACLES SHOWN BACK TO BACK SHALL BE OFFSET A MINIMUM OF 8" AND ACOUSTICALLY SEALED. 4. WHERE DIRECT CONNECTION TO PREWIRED FURNITURE PANELS OCCURS, PROVIDE POWER AND TELECOMMUNICATION FEEDS TO INDICATED PANEL LOCATION FROM WALL, COLUMN OR FLOOR SOURCE DIRECTLY ADJACENT TO THIS LOCATION. 5. ALL EXISTING FLOOR MOUNTED ELECTRICAL/TELECOMMUNICATION LOCATIONS WHICH ARE NOT REUSED ARE TO BE REMOVED. REMOVE ALL ASSOCIATED CABLE, WIRE AND CONDUIT BACK TO SOURCE. PROPERLY PATCH AND REPAIR AFFECTED WALL, FLOOR AND/OR CEILING CONSTRUCTION. 6. UNLESS OTHERWISE NOTED ALL DEVICE ELEVATIONS REFER TO BOTTOM OF OUTLET BOX. 7. REFER TO REFLECTED CEILING PLANS FOR LOCATIONS OF LIGHT SWITCHES. 8. ALL OUTLETS THAT ARE IN THE VICINITY OF ANY WET AREAS (KITCHENS, BREAK ROOMS, RESTROOMS, JANITORIAL ROOMS WITH FLOOR SINKS, LAUNDRY ROOMS, STAND ALONE WALL MOUNTED SINKS, ELECTRIC WATER FOUNTAINS,ETC.) GROUND FAULT INTERRUPT (G.F.I.) TYPE. SEE ELECTRICAL LEGEND. 2/A1.1 1/8' = 11-0" NORTH FLOOR PLAN 1/A1.1 ROOM FINISH SCHEDULE REFLECTED CEILING LEGEND WALLS REFLECTED CEILING PLAN GENERAL NOTES MILLWORK BUILDING STANDARD 2X4 NOT ALL MAY APPLY. CODE NOT ALL MAY APPLY. REFER TO REEL. CEILING PLAN FOR ADDITIONAL NOTES AND CEILING INFO. MANUFACTURER PATTERN FLUORESCENT LIGHT FIXTURE 3'-0" x NUMBER / COLOR REMARKS NO. NAME THREE$ LAMP ELECTRONIC BALLAST BASE WALL MOUNTED LIGHT SWITCH. COVER 1. REFER TO INDEX SHEET FOR TYPICAL WALL TYPES WALLS TO DECK, RATED WALLS, ETC AND ADDITIONAL ) WEST 18 C CELL PARABOLIC FIXTURE $3 PLATE COLOR TO MATCH EXISTING CTR. TOP WALL -TO -CEILING DESIGN CONDITIONS AND CONSIDERATIONS. 100 RECEPTION / WAITING CPT -1 ADJACENT COVER PLATES. ("3" DENOTES P-1 P-5 P-1 P-2 9'-0' BUILDING STANDARD 2X2 $� 3 -WAY SWITCH.) ("D" DENOTES DIMMER 2 PROVIDE NIGHT LIGHT CIRCUITS AS REQUIRED; G.C. TO COORDINATE WITH ELEC. ENGINEER. BROADLOOM CARPET VINYL COMPOSITION TILE Fil SNEAK PREVIEW, 2690 MULTICOLOR STD EXCELON FLUORESCENT LIGHT FIXTURE 26 OZ., DENSE PATTERENED LOOP SWITCH.) 3. CEILING GRID AND TILE SHALL BE BUILDING STANDARD. B-1 SEE TYP 2X4 NOTES ABOVE. P-1 P-1 4. THE ARCHITECTURAL REFLECTED CEIUNG PLANS SHALL GOVERN THE LAYOUT OF ALL CEILING ELEMENTS ACT -1 -- BUILDING STANDARD 2X4 0 SPRINKLER HEAD (EXISTING UNLESS 12"x12" TILE AND/OR PENETRATIONS. COORDINATE WITH ARCHITECT ANY FIELD VERIFIED OR AS -BUILT CONDITIONS LAN RM VCT -1 FLUORESCENT LIGHT FIXTURE P-1 OTHERWISE NOTED) P-1 THAT DIFFER FROM WHAT IS SHOWN ON THESE PLANS. 9'-0" ON NIGHT LIGHT CIRCUIT (U.O.N.) -- -- 5. SIZES OF MECHANICAL EQUIPMENT (IF SHOWN HERE) ARE SHOWN FOR REFERENCE ONLY. COORDINATE RESILIENT BASE JOHNSONITE O SPEAKER ACTUAL SIZES WITH MECHANICAL ENGINEER. _ _ --- -- - 103 OFFICE CPT -1 6. SIZES AND SHAPES OF LIGHTING AND OTHER MISC ELECTRICAL EQUIPMENT (IF SHOWN HERE) ARE SHOWN -" -- -- -- EXISTING CEILING GRID TO REMAIN. P-2 BUILDING STANDARD ILLUMINATED EXIT LIGHT ACT -1 FOR REFERENCE ONLY. COORDINATE ACTUAL SIZES WITH ELECTRICAL ENGINEER. ' - `C7 SOLID DENOTES DIRECTION OF FACEPLATE. SHERWIN WILLIAMS -- -- FLAT FINISH 104 OFFICE 7 UNLESS OTHERWISE NOTED INSTALL SUSPENDED CEILING GRID WITH EQUAL SIZE PANELS AT EACH SIDE P-1 P-1 P-1 P-2 9'-0' OR ENDS OF ROOMS. NO PANELS SHOULD BE LESS THAN 1'-0" WIDE. -- -- - P-2 P-3 PAINT EMERGENCY LIGHT FIXTURE W/ EMERGENCY EXIT LIGHTING PACK & BATTERY BACK UP. 8, IF POSSIBLE ANY CEILING MOUNTED ITEMS (SPRINKLER HEADS, MOUNTING MECHANISMS, ETC) SHOULD BE FLAT FINISH FLAT FINISH 105 BREAK RM CPT -1 B-1 P-1 INDICATES NEW CEILING GRID TO BE P-3 P-1 9'-0" CENTERED IN CEILING PANELS. MW PL -1 - INSTALLED. SHERWIN WILLIAMS "E" INCICATES EXISTING TO REMAIN. 9• WHERE EXISTING CEILING GRID IS REMODELED TO MEET NEW CONSTRUCTION THE CONTRACTOR SHALL: OPEN OFFICE CPT -1 B-1 P-1 P-1 "R" INCICATES EXISTING TO BE RELOCATED. P-1 A. REPLACE ALL DAMAGED OR UNREPAIRABLE PORTIONS OF EXISTING GRID WITH NEW GRID TO ACT -1 -- INDICATES NEW GYPSUM BOARD - UNLESS NOTED WITH AN "E" OR AN "R" ALL PAINT MATCH EXISTING BUILDING STANDARDS. -- BULKHEAD TO BE INSTALLED. SW6674, "JONQUIL" ITEMS SHOWN WILL BE NEW. 107 B. REMOVE PORTIONS OF EXISTING GRID OR PROVIDE NEW GRID AS REQUIRED BY NEW CONSTRUCTION. CPT -1 B-1 P-1 P-4 P-1 ALL NEW GRID MUST MATCH EXISTING TO REMAIN, OR BE BUILDING STANDARD. 9'-0" NEW INCANDESCENT DOWNLIGHT. -- -- - C. REPLACE ALL DAMAGED CEILING TILES WI1H NEW TILES TO MATCH EXISTING TO REMAIN, OR PAINT SHERWIN WILLIAMS -- SW6594, "POINSETTIA" 108 TO MATCH EXISTING BUILDING STANDARDS. ROOM FINISH SCHEDULE ROOM FINISH LEGEND ROOM FLOOR WALLS CEILING MILLWORK REMARKS CODE MATERIAL MANUFACTURER PATTERN 1 3'-0" x NUMBER / COLOR REMARKS NO. NAME FLOOR BASE NORTH EAST SOUTH WEST HEIGHT MATERIAL CABINETS CTR. TOP CASED OPEN'G 100 RECEPTION / WAITING CPT -1 B-1 P-1 P-5 P-1 P-2 9'-0' ACT -1 -- -- - CPT -1 VCT -1 BROADLOOM CARPET VINYL COMPOSITION TILE J & J COMMERCIAL ARMSTRONG SNEAK PREVIEW, 2690 MULTICOLOR STD EXCELON 6458, "WORLD PRIEMERE" 26 OZ., DENSE PATTERENED LOOP 101 STUDIO CPT -1 B-1 P-3 P-1 P-1 P-3 9'-0" ACT -1 -- -- - 52514, "JUBILEE' 12"x12" TILE 102 LAN RM VCT -1 B-1 P-1 P-1 P-1 P-1 9'-0" ACT -1 -- -- - B-1 RESILIENT BASE JOHNSONITE -- 14, "TROPICAL STORM" 4" VINYL COVE BASE 103 OFFICE CPT -1 B-1 P-1 P-1 P-1 P-2 T-0" ACT -1 -- -- - P-1 PAINT SHERWIN WILLIAMS -- SW7015, "REPOSE GRAY" FLAT FINISH 104 OFFICE VCT -1 B-1 P-1 P-1 P-1 P-2 9'-0' ACT -1 -- -- - P-2 P-3 PAINT SHERWIN WILLIAMS -- SW6832, "IMPULSIVE PURPLE" FLAT FINISH FLAT FINISH 105 BREAK RM CPT -1 B-1 P-1 P-1 P-3 P-1 9'-0" ACT -1 MW PL -1 - PAINT SHERWIN WILLIAMS -- SW6962, "DAllLE" 106 OPEN OFFICE CPT -1 B-1 P-1 P-1 P-4 P-1 9'-0' ACT -1 -- -- - P-4 PAINT SHERWIN WILLIAMS -- SW6674, "JONQUIL" FLAT FINISH FLAT FINISH SEMI -GLOSS FINISH MATTE FINISH; BREAK ROOM COUNTER TOP ONLY 107 OPEN OFFICE CPT -1 B-1 P-1 P-4 P-1 -- 9'-0" ACT -1 -- -- - P-5 P-6 PL -1 ACT -1 PAINT SHERWIN WILLIAMS -- SW6594, "POINSETTIA" 108 OPEN OFFICE CPT -1 B-1 -- P-1 -- P-1 9'-0" ACT -1 -- -- - PAINT SHERWIN WILLIAMS -- SW6544, "MESMERIZE" 109 STORAGE CPT -1 B-1 P-1 P-1 P-1 P-1 9'-0' ACT -1 -- -- - PLASTIC LAMINATE FORMICA -- 7711-58, "METALLIC GAUZE" ACOUSTICAL CEILING TILE ARMSTRONG GEORGIAN 2x2 WHITE USE WITH BUILDING STANDARD GRID SYSTEM. W/ BRITE CHROME WIRE PULLS MW MILLWORK MERILLAT AVIA WHITE m ELEVATION :4 6/A1.l 1/2'= 1'-T N i r-------------� I /TENANT SUPPLIED BUILDING STANDARD DOUBLE REFRIGERATOR COMPARTMENT STAINLESS STEEL SINK WITH GOOSENECK FAUCET AND LEVER HANDLES In I------------ 2'- 6' 1 3' 1 3' 1 3' NOTE: PROVIDE AND INSTALL 1/4" COPPER WATER LINE TO TENANT SUPPLIED REFRIGERATOR AND COFFEE MAKER. G.C. TO COORDINATE WATERLINE HOOK-UP TO ICEMAKER IN REF. ELEVATION 5/Al A 1iI =T -T SECTION TYPICAL UPPER CABINET. SEE ROOM FINISH SCHEDULE. HARDWARE TO BE WIRE PULLS. 3/4" PARTICLE BOARD COVERED WITH PLASTIC LAMINATE. SEE ROOM FINISH SCHEDULE. PROVIDE 4" HIGH BACKSPLASH. HARDWARE TO BE WIRE PULLS. TYPICAL BASE CABINET. SEE ROOM FINISH SCHEDULE. NOTE: 1. PROVIDE WOOD BLOCKING AS REQUIRED. 2. PROVIDE 1/4" CHAMFER ALONG FRONT EDGE OF COUNTER TOP. 3. SECTION SHOWN FOR REFERENCE ONLY. 4/A1.1 3l4' =1'-0' DOOR PROVIDE 6'-0"W. X 5'-0"H. X Y"TH. TEMPERED CLEAR GLASS PANEL W/ FINISH NO. TYPE SIZE JAMB 100 1 3'-0" x FULL HT. 101 1 3'-0" x 8'-O"H. 102 1 3'-0" x 8'-0' 103 1 S-0" x 8'-0' 104 1 3'-0" x 8'-0" 105 CASED OPEN'G 3'-0" X 8'-0" 109 1 3'-0" x 8'-0" POOR TYPE -- HOLLOW MTL (4) LAN DROPS SEE -- (4) TELEPHONE LINES -- SCHEDULE � AUDIO VAULT POTS SEMI -GLOSS FINISH W J PRIZE LINE POTS -- HOLLOW MTL 0 w 1 -- HOUSE PHONE CONNECTED TO SYSTEM U 3 EACH WALL TO RECEIVE (1) DUPLEX OUTLET SEMI -GLOSS FINISH cn -- HOLLOW MTL w w cn 1 -- -- TYPE 1 MATERIAL FINISH SOLID WOOD STAINE SOLID WOOD STAINE SOLID WOOD -- SOLID WOOD -- SOLID WOOD -- SOLID WOOD -- FRAME TYPE DOOR(S) WIDTH H 2 2 c c C TYPE 1 GENERAL FLOOR PLAN NOTES NOT ALL MAY APPLY. REFER TO PLANS FOR ADDITIONAL NOTES AND INFORMATION. 1. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL DIMENSIONS, JOB CONDITIONS, ETC. 2. ALL DIMENSIONS ON PLANS ARE TO FINISHED FACE OF MTL STUD WALL, CONCRETE MASONRY UNIT OR BRICK. 3. WHERE DISSIMILAR FLOOR MATERIALS MEET THEY SHALL DO SO UNDER THE CENTERLINE OF THE DOOR, UNLESS NOTED OTHERWISE. 4. PROVIDE DEEP LEG TRACKS AT ALL METAL STUD CONNECTIONS TO STRUCTURE ABOVE. UNLESS NOTED OTHERWISE, 5. HINGE SIDE OF DOOR JAMBS IN METAL STUD WALLS WILL TYPICALLY BE LOCATED 4" FROM ADJACENT WALL. UNLESS NOTED OTHERWISE. SEE TYPICAL DETAILS ON INDEX SHEET FOR ADDITIONAL INFORMATION. 6. PROVIDE BLOCKING IN NEW METAL STUD WALLS FOR ALL WALL SUPPORTED ITEMS. 7. PROVIDE FIRE STOPPING AT PENETRATIONS OF ALL RATED WALLS. 8. SEE REFLECTED CEILING PLANS FOR BULKHEAD LOCATIONS AND ASSOCIATED DETAIL REFERENCES. 9. REFER TO DEMOLITION PLAN FOR ALL REQUIRED DEMOLITION WORK. 10. REFER TO ROOM FINISH SCHEDULE FOR ALL REQUIRED FINISH INFORMATION. 11. REFER TO DOOR SCHEDULE FOR ALL DOOR AND FRAME TYPES, HARDWARE INFORMATION AND ALL OTHER DOOR INFORMATION. 12. WHERE NEW WALL CONSTRUCTION IS SHOWN ABUTTING WINDOW MULLIONS, CENTER WALL CONSTRUCTION ON MULLION REFER TO TYPICAL DETAILS ON INDEX SHEET FOR ADDITIONAL CONSTRUCTION INFORMATION. 13. WHERE NEW WALL CONSTRUCTION IS REQUIRED ADJACENT TO OR ABUTTING EXISTING CONSTRUCTION ALIGN FACE OF NEW CONST. WITH FACE OF EXISTING CONST. SEE TYPICAL DETAILS ON INDEX SHEET FOR ADDITIONAL INFORMATION. 14. ALL FINISHES SHALL CONFORM TO CHAPTER 8 OF THE 2000 INTERNATIONAL BUILDING CODE AND THE INDIANA FIRE CODE 15. WHERE POSSIBLE LEAVE 1'-6" OF UNOBSTRUCTED SPACE ON LATCH/PULL SIDE OF ALL DOORS AND 1'-0" OF UNOBSTRUCTED SPACE ON LATCH/PUSH SIDE OF DOORS FOR A.D.A. COMPLIANCE. 16. USE ONLY PLENUM RATED CABLE. 17. THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN HIS SCOPE OF WORK TO DISCONNECT AND RECONNECT TENANT'S EXISTING POWERED SYSTEMS FURNITURE. IF TENANT IS INSTALLING NEW POWERED SYSTEMS FURNITURE ELECTRICAL CONTRACTOR SHALL INCLUDE PRICE TO CONNECT. 18. UNLESS OTHERWISE NOTED ALL INTERIOR WALLS WILL BE TYPE #1. SEE WALL TYPES ON INDEX SHEET FOR ADDITIONAL INFO. 19. PROVIDE CONTROL JOINTS IN ALL RUNS OF METAL STUD/GYP BD WALLS OVER 30' IN LENGTH. COORDINATE LOCATIONS WITH CARSON DESIGN ASSOCIATES PRIOR TO INSTALLATION FOR COMPLIANCE WITH DESIGN INTENT. NOTE: HVAC CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING ADEQUATE HEATING, COOLING AND HUMIDITY CONTROL (AS APPLICABLE) IN ALL SPACES FORMED BY NEW CONSTRUCTION AS WELL AS ANY EXISTING SPACES RECONFIGURED BY NEW CONSTRUCTION. REFER TO MECHANICAL DRAWINGS FOR ALL LOCATIONS OF HVAC EQUIPMENT, EITHER SHOWN HERE OR NOT SHOWN HERE, AND COORDINATE WITH ARCHITECT OR ARCHITECT'S FIELD REPRESENTATIVE ANY CONFLICTS DISCOVERED BETWEEN ARCHITECT'S AND MECHANICAL ENGINEER'S DRAWINGS. NOTE: SPRINKLER CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING ADEQUATE SPRINKLER LAYOUT IN ALL SPACES FORMED BY NEW CONSTRUCTION AS WELL AS ANY EXISTING SPACES RECONFIGURED BY NEW CONSTRUCTION. LAYOUT MUST MEET ALL APPLICABLE LOCAL AND STATE CODES. REFER TO SPRINKLER DRAWINGS FOR ALL LOCATIONS OF THAT EQUIPMENT, EITHER SHOWN OR NOT SHOWN HERE, AND COORDINATE WITH ARCHITECT OR ARCHITECT'S FIELD REPRESENTATIVE, AND MECHANICAL ENGINEER ANY CONFLICTS DISCOVERED BETWEEN SPRINKLER CONTRACTOR'S DRAWINGS AND ARCHITECT'S OR MECHANICAL ENGINEER'S DRAWINGS. NOTE: ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR THE REWIRING AND/OR RE -SWITCHING OF ALL LIGHT FIXTURES AND/OR LIGHT SWITCHES AS REQUIRED BY NEW CONSTRUCTION. COORDINATE WITH ARCHITECT ANY ADDITIONAL REQUIRED WORK NOT SHOWN HERE. ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER OTHER TRADES' DRAWINGS WHEN CONFLICTS ARISE. BRING CONFLICTS OR INCONSISTENCIES BETWEEN ARCHITECTURAL DRAWINGS AND DRAWINGS OF OTHER DISCIPLINES TO THE ATTENTION OF THE ARCHITECT. KEYNOTES O PROVIDE 6'-0"W. X 5'-0"H. X Y"TH. TEMPERED CLEAR GLASS PANEL W/ FINISH 'HOLLOW METAL FRAME TO MATCH BLDG. STANDARD DOOR FRAMES. SEE RATING ELEV. 6/A1.1 FOR ADDITIONAL INFORMATION. JAMB 2O PROVIDE WALL -MOUNTED 8'-0"W. X 4'-O"H., 3/" TH. PLYWOOD BACKER. Q PAINT TO MATCH ADJACENT WALL. O PROVIDE 24"D. COUNTERTOP AND BASE CABINETS BELOW W/ 12"D. UPPER 0 CABINETS. SEE ELEV. 5/A1.1. Q O PROVIDE 3 %" METAL STUD CONSTRUCTION, THIS WALL ONLY. O PROVIDE 24/7 AIR-CONDITIONING IN THIS ROOM ONLY. O G.C. TO COORDINATE WITH TENANT FOR SPECIFIC SYSTEMS FURNITURE -- POWER REQUIREMENTS. -- O PROVIDE THE FOLLOWING FOR ROOM 101: SPLIT FINISH 2E (3) DEDICATED, 110V., 20 AMP OUTLETS -- HOLLOW MTL (4) LAN DROPS 1 -- (4) TELEPHONE LINES -- 2 AUDIO VAULT POTS SEMI -GLOSS FINISH PRIZE LINE POTS -- HOLLOW MTL HYBRID POTS 1 -- HOUSE PHONE CONNECTED TO SYSTEM -- -- -- 3 EACH WALL TO RECEIVE (1) DUPLEX OUTLET SEMI -GLOSS FINISH DOOR SCHEDULE FRAME CARSON DESIGN ASSOCIATES TEL 317.8435979 FAX 317.843.5975 11590 N. MERIDIAN SUITE 104 CARMEL INDIANA 46032 TEL 512.977.0520 FAX 512.977.0384 12301 RESEARCH BLVD. BUILDING IV, SUIrM 104 AUSTIN TEXAS 78759 www.carsondesign.com "HIS DRAWING AND THE IDEAS, CONCEPTS AND DESIGNS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CARSON DESIGN ASSOCIATES, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CARSON DESIGN ASSOCIATES. 0 COPYRIGHT 2003 CARSON DESIGN ASSOCIATES STAMP :01M RATING MATERIAL FINISH TYPE RATING HEAD JAMB HDWRE. REMARKS Q COD 0 Q C/)Co o D -- HOLLOW MTL BLDG. STD./P-3 1 -- -- -- 1 z SPLIT FINISH 2E D -- HOLLOW MTL P-6 1 -- -- -- 2 SEMI -GLOSS FINISH -- HOLLOW MTL P-6 1 -- -- -- -- -- 3 SEMI -GLOSS FINISH -- HOLLOW MTL P-6 1 -- -- 2 SEMI -GLOSS FINfSH -- HOLLOW MTL P-2 1 -- -- 2 SEMI -GLOSS FINISH -- HOLLOW MTL P-6 1 -- -- -- 3 SEMI -GLOSS FINISH HARDWARE LEGEND GENERAL DOOR NOTES: 1. DOOR STOPS TO BE WALL MOUNTED UNLESS NOTED OTHERWISE IN DOOR HARDWARE SET 11 HARDWARE SET #2 HARDWARE SET #3 SCHEDULE REMARKS. PROVIDE BLOCKING INSIDE WALL FOR STOPS. 4 HINGES 4 HINGES 1 ENTRANCE LOCK 4 HINGES 2. ALL NEW DOORS TO RECEIVE BUILDING STANDARD LEVER HANDLES. 1 DOOR STOP 1 ENTRANCE/ 1 STOREROOM LOCK 3. ALL DOORS, (EXCEPT DOOR 100), TO BE SOLID CORE CHERRY DOORS 3 MUTES 1 CLOSER CLOSERDEADBOLT OFFICE LOCK 1 1 DOOR STOP 3 DOOR STOP MUTES WITH A BUILDING STANDARD FINISH AND HOLLOW METAL KNOCK 1 3 MUTES 1 CLOSER DOWN FRAMES, BUILDING STANDARD. 1 ASTRAGAL SET FINISH: BLDG. STD. 1 DOOR HOLDER 4. ALL LOCKS AND LATCHES TO BE BUILDING STANDARD "BEST ACCESS SYSTEMS" FINISH: BLDG. STD. FINISH: BLDG. STD. CARSON DESIGN ASSOCIATES TEL 317.8435979 FAX 317.843.5975 11590 N. MERIDIAN SUITE 104 CARMEL INDIANA 46032 TEL 512.977.0520 FAX 512.977.0384 12301 RESEARCH BLVD. BUILDING IV, SUIrM 104 AUSTIN TEXAS 78759 www.carsondesign.com "HIS DRAWING AND THE IDEAS, CONCEPTS AND DESIGNS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CARSON DESIGN ASSOCIATES, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CARSON DESIGN ASSOCIATES. 0 COPYRIGHT 2003 CARSON DESIGN ASSOCIATES STAMP :01M WLu Q COD 0 Q C/)Co o 0 Li -i T -Lu z W s z Cly 2E ca O Q Q U ISSUE: STATE REVIEW 2 JULY 03 FOR CONSTRUCTION 8 JULY 03 SQUARE FOOTAGE: DRAWING .LE LANS SCHEDULES AND DETAILS JOB NO. DATE: SHEET NUMBER: Al A