Loading...
HomeMy WebLinkAbout03080117.3LL 0 Z W — �O LU Z F- _ VU Z F— Z O U DOOR ELEVATION General Notes- Doors 1, Furnish hardware items in the amount indicated unless additional hardware is required for a complete and operable facility. Ensure completeness, proper function, and proper application of hardware for each door. Provide complete hardware for each and every door shown on the drawings irrespective of its inclusion in this schedule or the door schedule shown on the specifications. 2. All finish hardware shall comply with the American Disabilities Act Accessibility Guidelines (ADAAG) and the Ohio Basic Building Code (OBBC), 3. All door latch handles to be the lever type. 4. Glazing in hazardous locations indicated as tempered glazing shall Conform to the requirements of the CPSC 16.1201 and bear a manufacturers designation. 5. All door jambs to be set off the perpendicular wall 4", unless noted otherwise. HARDWARE NOTES HARDWARE SET A A. 11/2 PR BUTT HINGES DOOR FRAME HARDWARE CLOSER REMARKS DOOR NUMBER Lu X x LLI Z Z Q CL LU Z uJ Q LUJ ty- SIZE g j J Lu co J 0 � �- j J Lu DETAIL HARDWARE SET C HINGES BEST 73K (MEDIUM 3 PR BUTT HINGES WIDTH HEIGHT HEAD JAMB 100A 1 FLUSH BOLT & HINGES: STANLEY 41/2, 2 PER DUSTPROOF STRIKE 0 8'-0" GLASS 2 • HM 3 2 1 EXIST'G --�_--- --- 100B� • _e'-0" 6'-0" 8'-0" WD 2 HM 3 2 1 D 102A • 3'-0" 8'-0" WD 1 HM 2 2 1 EXIST'G •-- 102B • • T-0" 8'-0" WD 1 HM 2 2 1 EXIST'G • --^ 103A • 3'-0" 8'-0" WD 1 HM 1 2 1 EXIST'G _ -- 104A • 3'-0" 8'-0" WD 1 HM 1 2 1 1 EXIST'G 105A 61 T-0" 8'-0" WD 1 HM EXIST'G EXIST'G EXIST'G EXIST'G 106A 01 3'-0" 8'-0" WD 1 HM EXIST'G EXIST'G EXIST'G EXIST'G _ �107A 01 3'-0" 8'-0" WD 1 HM EXIST'G EXIST'G EXIST'G EXIST'G 108A • 3'-0" 8'-0" 1 HM EXIST'G EXIST'G EXIST'G EXIST'G 109A • 3'-0" 8'-0" _WD WD 1 HM EXIST'G EXIST'G EXIST'G EXIST'G v 110A • 3'-0" 8'-0" WD 1 HM EXIST'G EXIST'G EXIST'G EXIST'G 111A • 3'-0" 8'-0" WD 1 HM EXIST'G EXIST'G EXISTG EXIST'G _ 114A • 3'-0" 8'-0" WD 1 • HM EXIST'G EXISTG EXISTG EXIST'G _ 115A • 3'-0" 8'-0" WD 1 HM 2 2 1 _ B 116A • 3'-0" 8'-0" WD 1 HM 2 2 1 B 117A • 3'-0" 8'-0" WD 1 HM 2 2 1 B 119A • 3'-0" 8'-0" WD 1 H9 2 2 1 EXIST'G 120A _ • 3'-0" 8'-0" WD 1 HM 2 2 1 EXIST'G — ---- 1_21 A 8'-0" WD 1 • HM 1 2 1 A -- — 122A •8'-0" Lai WD 1 2 HM 3 2 1 C _ — ---- 123A 8'-0" 1 WD 2 HM 3 2 1 1 1 EXIST'G General Notes- Doors 1, Furnish hardware items in the amount indicated unless additional hardware is required for a complete and operable facility. Ensure completeness, proper function, and proper application of hardware for each door. Provide complete hardware for each and every door shown on the drawings irrespective of its inclusion in this schedule or the door schedule shown on the specifications. 2. All finish hardware shall comply with the American Disabilities Act Accessibility Guidelines (ADAAG) and the Ohio Basic Building Code (OBBC), 3. All door latch handles to be the lever type. 4. Glazing in hazardous locations indicated as tempered glazing shall Conform to the requirements of the CPSC 16.1201 and bear a manufacturers designation. 5. All door jambs to be set off the perpendicular wall 4", unless noted otherwise. HARDWARE NOTES HARDWARE SET A A. 11/2 PR BUTT HINGES O O D 1 LOCKSET HARDWARE SET D 1 FLOOR STOP 3 PR BUTT HINGES E C 2 DUMMY HANDLES HARDWARE SET B 2 OVERHEAD STOPS 11/2 PR BUTT HINGES COLUMBUS, 1 LATCHSET BUILDING STANDARD HARDWARE 1 FLOOR STOP HANDSETS: BEST 93K (HEAVY 4— 4 6 1 DUTY) W/ CLOSERS AND BB HARDWARE SET C HINGES BEST 73K (MEDIUM 3 PR BUTT HINGES DUTY) 1 LATCHSET CLOSERS: NORTON 1 FLUSH BOLT & HINGES: STANLEY 41/2, 2 PER DUSTPROOF STRIKE FINISH: POLISHED CHROME, US26D, LINO 5/8" GYPSUM BOARD — SEALANT 3 5/8 MTL. STUD ONE-WAY VISION GLASS HOLLOW MTL. FRAME SEALANT 3 5/8 MTL. STUD 5/8" GYPSUM BOARD 64, 3 DETAIL 1 1/2"=1'-0" 6, 0„ 3 FRAME ELEVATION 3'-0" 3'-0" L �. DOOR ELEVATION 2 1/4"=l. -O" 5/8" GYPSUM BOARD — SEALANT 25 GAUGE METAL TRACK HOLLOW METAL FRAME 2 HEAD 1 1/2"=1'-0" *- 3.4" r-2- 3 p^ r 2 FRAME ELEVATION 1/4"=I' -O" b L 3,'a" L DOOR ELEVATION 1/4"= 1 1-01, Floor Plan 4 ao EXTENT OF ��_ NOT IN WORK CONTRACT AREA NOT IN CONTRACT HOLLOW METAL FRAM SEALANT —� 5/8" GYPSUM BOARD ---� DOUBLE 25 GAUGE METAL STUDS OR SINGLE 20 GAUGE METAL STUD SEALANT IDJAMB 1 1/2"=1'-0" T-2' 2" 2'-0' CLEAR TEMPERED GLASS SIDELITE FRAME E—LE—VATION 1/4"=l' -O" W WINDOW ELEVATION < > 1 1/4"=1'-0" DPA David rontla Arohltooturo and Plonaloo Yi I .&W Pt v Cnv*M . Mo 4=1 5 a 7 t 4 2937 te. 614.064.0646 ntlu�OpOatC tlpuplt9cty r0. c om GENERAL NOTES 1 POST SUITABLY DESIGNED PLACARD IN A FORM DESIGNATED BY THE BUILDING OFFICIAL. IT SHALL BE SECURELY FASTENED TO THE STRUCTURE IN A READILY VISIBLE PLACE STATING, THE USE GROUP TYPE OF CONSTRUCTION, LIVE LOADS AND OCCUPANT LOADS, 2. PORTABLE FIRE EXTINGUISHERS SHALL BEAR THE LABEL OF AN APPROVED AGENCY, AND BE 10# ABC TYPE, PER SECTION 9211 AND BE INSTALLED AS INDICATED ON PLANS AND SHALL COMPLY WITH NFPA 10, 3, ALL DIMENSIONS ARE WITNESSED TO FACE OF STUD UNLESS NOTED OTHERWISE, 4, ANY DAMAGE TO EXISTING CONDITIONS THAT OCCURS DURING DEMOLITION SHALL BE REPAIRED/REPLACED 5. INDICATES NEW WALL CONSTRUCTION 8.INDICATES MEANS OF EGRESS AND OCCUPANCY LOAD 7. SEE PLUMBING FOR ALL FLOOR DRAIN LOCATIONS, 8. REFER TO EQUIPMENT PLAN FOR ALL KITCHEN EQUIPMENT SPECIFICATIONS AND LOCATIONS. 0 CODED NOTES 1. CENTER WALL ON WINDOW MULLION OR COLUMN. 2, FULL SOUND ATTENUATION INSULATION TO BE APPLIED 4' EITHER SIDE ON LAY -IN CLG, 3. ALIGN NEW WALL WITH EXISTG ADJACENT REVISIONS DATE AJuly 20, 2003 ............................. A - .... ............... PROJECT TITLE Nkrawwct Tenant Improvements 500 East 96th Street Indianapolis, Indiana 46240 SHEET TITLE Floor Plan, Door and Window Schedule, Elevations and Details SCALE AS NOTED DATE: July 3, 2003 PROJECT NUMBER: 2003-22 rrM14r FtTH(/'9 Qom.: Na A 1 00 26 L,STTE 6 3 ,ti l � �RrHIT F R E D R I C A. G O O D M A N A R C H I T E C T S 182 EAST LONG ST. — SUITE 100 COLUMBUS, OHIO 43215 6 1 4— 4 6 1 — 1 3 0 0 SHEET NUMBER A-100 eyerswe s architecture+ciesign 22 east gay street, suite 301 Columbus, ohio 43215 t: 614.221.9433 f: 614.221.9441 N