HomeMy WebLinkAbout03080117.8zz LJwr.1 W W W li LA- t Ix W Q Q Q w11 x WWW N c� L)o Z C7 p ZLAJ a.oa_ A B 6 ( 7 1 LIGHTING FIXTURE NOTES 81 NEW OR EXISTING THREE (3) LAMP DEEP CELL PARABOLIC 2 X 4 LIGHTING FIXTURE. NEW LIGHTING FIXTURE EQUAL TO LITHONIA #2PM3G6-332-18-277. LAMPS EQUAL TO GE# F32T8/SPX35. BALLAST EQUAL. TO SPECIFICATIONS. REFER TO GENERAL NOTE B THIS SHEET FOR EXISTING FIXTURE SPECIFICATIONS. PROVIDE TWO (2) BALLAST IN FIXTURE AS NOTED ON THE PLANS FOR MULTI-LEVEL LIGHTING, B2 NEW THREE (3) LAMP DEEP CELL PARABOLIC 2 X 4 LIGHTING FIXTURE. NEW LIGHTING FIXTURE EQUAL TO LITHONIA #2PM3GB-332- 18-277 WITH EMERGENCY BATTERY BALLAST EQUAL TO SPECIFICATIONS. LAMPS EQUAL TO GE# F32T8/SPX35. BALLAST EQUAL TO SPECIFICATIONS. B3 NEW OR EXISTING TWO (2) LAMP DEEP CELL PARABOLIC 2 X 2 LIGHTING FIXTURE. NEW LIGHTING FIXTURE EQUAL TO LITHONIA B #2PM3N-GB-2-U316-9-277. LAMPS EQUAL TO N2T SX3/U/6. BALLAST EQUAL TO SPECIFICATIONS. REFER TO GENERAL NOTE B THIS SHEET FOR EXISTING FIXTURE SPECIFICATIONS. B3 NEW TWO (2) LAMP DEEP CELL PARABOLIC 2 X 2 LIGHTING FIXTURE. NEW LIGHTING FIXTURE EQUAL TO LITHONIA #2PM3N—GB-2—U316-9— FOURTH FLOOR PARTIAL FLOOR PLAN_ SCALE: 1/$ = 1'-0" GENERAL NOTES A REMOVE ALL LIGHTING FIXTURES IN AREAS OF ALTERATION. LIGHTING FIXTURES ARE TO BE REUSED WHERE AS NOTED ON THE PLANS, AND IN THE LIGHTING FIXTURE NOTES. B LIGHTING FIXTURES BEING REUSED: THE ELECTRICAL CONTRACTOR SHALL CLEAN AND RELAMP FIXTURE PRIOR TO INSTALLATION. MAINTAIN LIGHTING FIXTURES INTEGRITY DURING DEMOLITION WORK AND NEW WORK. LIGHTING FIXTURES NOT BEING RELOCATED BECOME PROPERTY OF THE OWNER, VERIFY WITH THE OWNER PRIOR TO DISCARDING OF ANY LIGHTING FIXTURE. C REFER TO LIGHTING FIXTURE NOTES FOR ADDITIONAL DIRECTION OF EXISTING FIXTURES. D MAINTAIN EXISTING CIRCUITRY WHEN EXISTING LIGHTING FIXTURES ARE REMOVED, EXISTING CIRCUITRY SHALL BE REUSED FOR NEW LIGHTING FIXTURE LAYOUT. E WHERE NEW LIGHTING CIRCUITS ARE REQUIRED HOMERUN CIRCUITS TO EXISTING BRANCH CIRCUIT PANELBOARDS. PROVIDE A NEW 20 AMP CIRCUIT BREAKER TO MATCH EXISTING PANEL MANUFACTURE AND AIC RATING (2-#12 THHN AND 1-#12 THHN CRD. IN .5" CONDUIT MINIMUM WIRE SIZE). F THE ELECTRICAL CONTRACTOR SHALL FIELD ASSESS THE EXISTING FACILITY PRIOR TO THE START OF WORK THE ELECTRICAL CONTRACTOR a 0 NOTES 1 EXISTING LIGHTING FIXTURE TO BE RELOCATED, REFER TO GENERAL NOTE B THIS SHEET. 2 EXTEND WIRE AND CONDUIT TO THE RESPECTIVE LIGHTING FIXTURE FROM THE WALL SWITCH. LOWER CASE LETTER DENOTES SWITCHING ARRANGEMENT. 3 WIRE NIGHT LIGHT / EMERGENCY CIRCUIT AHEAD OF ALL LOCAL SWITCHING. 4 WIRE NEW NIGHT LIGHT INTO EXISTING NIGHT LIGHT / EMERGENCY LIGHTING FIXTURE. WIRE NEW LIGHTING FIXTURES AHEAD OF ALL LOCAL SWITCHING. 5 EXTEND WIRE AND CONDUIT TO EXISTING CIRCUIT. WHERE NEW CIRCUIT IS REQUIRED, RUN A NEW 277 VOLT CIRCUIT FROM EXISTING 480/277Y PANEL. LIGHTING CIRCUITS SHALL NOT EXCEED CODE MINIMUMS FOR A 20 AMP CIRCUIT BREAKER (3500 MAX WATTS), 6 EXISTING GRAPHIC EYE LIGHTING CONTROL PANEL RELOCATED. 7 EXISTING GRAPHIC EYE REMOTE LIGHTING CONTROLLER RELOCATED. MOUNT EXISTING CONTROL AT 48" AFF. 8 EXTEND WIRE AND CONDUIT VIA EXISTING RELOCATED GRAPHIC EYE LIGHTING CONTROL PANEL. MAINTAIN EXISTING LIGHTING CONTROL FOR MPR ROOM. WIRE UGHTING CONTROL PANEL PER MANUFACTURER'S WIRING PROJECT NO 2032118 HEAPY ENGINEERING MECHANICAL ELECTRICAL CONSULTANTS DAYTON, OHIO (937)224-0861 COLUMBUS, OHIO (614)457-2696 This drawing is copyrighted and is the sole property of Meyers -Welsh Arch itectu re+ Design, LLC It is produced for use by the property owner Reproduction or other use of this drawing or the information contained herein without the written permission of the architect is strictly prohibited All rights reserved Copyright 2003 REVISIONS DATF Q07/21/M A O.. ................... PROJECT TITLE MICROS -OFT Tenant Improvements 500 East 96th Street Indianapolis, Indiana 46240 SHEET TITLE SCALE AS NOTED DATE: July 10, 2003 MEYERS-WELSH PROJECT NUMBER: 2003-22 SHEETNUMBER io 277 WITH EMERGENCY BATTER BALLAST EQUAL TO SPECIFICATIONS. IS HELD RESPONSIBLE TO MAKE ALL FINAL CONNECTIONS TO THE DIAGRAM. MAINTAIN EXISTING CIRCUITRY FOR POWER WIRING. U� q LAMPS EQUAL TO GE# F32T8/SPX35/U/6. BALLAST EQUAL TO NEW, RELOCATED, AND EXISTING. ELECTRICAL DEVICES FOR A SPCIFICATIO COMPLETE AND OPERATIONAL SYSTEM AS SHOWN ON THE ELECTRICAL 9 WIRE INSIDE LAMP BALLAST SEPARATE FROM OUTSIDE LAMP BALLAST " DOCUMENTS AND SPECIFIED HEREIN. FOR MULTI LEVEL LIGHTING. F1 NEW RETRACTABLE 6 DOWNLIGHT. NEW LIGHTING FIXTURE EQUAL cz):D TO PRESCOLITE #1586-800. LAMP EQUAL TO GE# 100PAR/HIR/FL. 10 EXTEND WIRE AND CONDUIT FROM EXISTING 208/120V BRANCH Za rn ROUGH -IN SIZE: 8.625 D X 12.75 H. CIRCUIT PANEL FOR NEW INCANDESCENT LIGHTING FIXTURES. - �� F2 TECH LIGHTING 700FJRDWC24. LAMP EQUAL TO GE #Q50MR16C. 1 1 PROVIDE LIGHTING FIXTURE WITH A SWITCHABLE EMERGENCY 0 W W 6 a CABLE MOUNT 8'-0' AFF ABOVE DESK. BALLAST EQUAL TO BODINE. WIRE BALLAST INTO FIXTURE PER ZaVi SIG EQUAL TO DUAL- MANUFACTURES WIRING DIAGRAMS SUCH THAT UPON LOSS OF POWER X1 NEW THERMOPLASTIC LED N. EXIT THE FIXTURE WILL AUTOMATICALLY ILLUMINATE, 0w m UTE #LXURWE CEILING SURFACE MOUNT OR WALL MOUNT ABOVE DOOR, =-J :2 12 EXISTING BRANCH CIRCUIT PANELBOAROS. VERIFY EXACT LOCATIONS o W AND VOLTAGES PRIOR TO CONSTRUCTION. THE ELECTRICAL zCONTRACTOR IS HELD RESPONSIBLE TO MAKE ALL FINAL CONNECTIONS �- P I O.. TO THE NEW, RELOCATED, AND EXISTING ELECTRICAL DEVICES AS REQUIRED SYSTEM. w a z FOR A COMPLETE AND OPERATIONAL wr CL E-1 22 east gay street, suite 301 columbus, Ohio 43216 t: 614.221.9433 f: 614.221.9441