HomeMy WebLinkAbout03080109.1ARCHITECT:
cso
600 E. 96TH STREET, SUITE 550
INDIANAPOLIS, INDIANA 46240
1317) 848.7800 (317) 574.1889 FAX
CONTRACTOR:
`.
Duke
REALTY CORPORATION
600 E. 96th STREET
SUITE 100
INDIANAPOLIS, IN 46240
PHONE: (317)808-6000
INDEX OF DRAWINGS
• COVER
CONTRACT CONDITIONS
• 4A201
CONSTRUCTION &REFLECTED CEILING PLAN
• 4A202
CORRIDOR CONSTRUCTION &REFLECTED CEILING PLAN
• 0801
FINISH &ELECTRICAL PLAN
• SM -1
HVAC PLAN
APPROVED AS SUBIAITTED APPROVED AS NOTED � P.EJECTED
SIGNATURE - DATE
COMPANY
KEYPLAN
SCALE: NTS
N
EIGHT PARKWOOD
SPECIFICATIONS AND GENERAL NOTES
SUITE 450
0
CONTRACT CONDITIONS
1.11
PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL
6.7 MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH
F
N.
CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION
PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS.
0.1
THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1987 EDITION,
EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE
6.8 DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING,
ENTITLED "GENERAL CONDITIONS OF THE CONTRACT FOR
PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED
CONSTRUCTION". THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF
1.12
PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION
WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY
THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE
NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND
OPERATING FOR TEN DAYS.
RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED
w N
MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN
6.9 INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND
AS FOLLOWS:
THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE
STRAIGHT WITH NO DISTORTIONS.
INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL
6.10 JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM
3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND
PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD.
WIDTH NOT TO EXCEED 1/8 U.O.N.
zg
FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE
6.11 GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL
PROCEEDING WITH CONSTRUCTION.
2
DEMOLITION
OUTLETS.
3.3 SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE
RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS,
2.1
COORDINATE DEMOLITION WITH CONSTRUCTION PLANS TO DETERMINE
METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES.
EXTENT OF WORK, PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE
7 JOINT SEALERS
3.7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY
�
BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW
• �i.l s
GOVERNMENTAL FEES, LICENSES AND INSPECTIONS.
. �
WORK.
7.1 ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS
3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING
2.2
WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR
AND FIXTURES:
ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND
EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT,
.1 "DOW CORNING 786'; DOW CORNING CORP.
WORKMANSHIP.
OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION
.2 "SCS 1702 SANITARY"; GENERAL ELECTRIC CO.
10.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY
TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND
.3 "863 #345 WHITE"; PECORA CORP.
U
PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE
SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING
.4 "PROGLAZE WHITE"; TREMCO CORP.
v v
g �oyv
CONTRACTOR'S RESPONSIBILITY.
ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND
.5 "OMNIPLUS"; SONNEBORN BUILDING PRODUCTS
y
WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED
0.2
WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES,
TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR
7.2 ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING
RULES AND REGULATIONS.
E
ADDITIONAL WORK RELATED TO SUCH ACTIVITIES.
SURFACES:
0.3
ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD
2.3
WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED
.1 "CHEM -CALK 6D0"; BOSTIK CONSTRUCTION PRODUCTS DIV.
QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF
MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS ShALL
.2 7AC-20"; PECORA CORP.
THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION
BE INCLUDED.
.3 "SONOLAC"; SONNEBORN BUILDING PRODUCTS
IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED
2.4
REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE
.4 "TREMCO ACRYLIC LATEX 834"; TREMCO, INC.
PROJECT.
DRAWINGS.
0.4
WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE
2.5
ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE
8 DOORS AND WINDOWS
SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND
ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED
WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE
FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND
8.1 INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS
SPECIFIED CAPACITIES OF THE EQUIPMENT.
METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW
NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER.
0.5
WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS
FINISHES.
8.2 INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED
ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING
2.6
EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL
OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH.
JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL
REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR
8.3 DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH
GOVERN THE WORK.
NOTED TO BE REPAIRED.
AND LOCKSETS.
0.6
NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE
2.7
SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS.
8.4 GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048
SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN
2.8
REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS
REQUIREMENTS FOR HEAT -STRENGTHENED GLASS.
DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT
REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK
CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY
IN SCOPE OF CONTRACT.
9 FINISHES
OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S
2.9
PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING
INTERPRETATION.
DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS
9.1 GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645.
0.7
INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH
ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS
MANUFACTURER'S RECOMMENDATIONS.
SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT
.1 INSTALL "ELIMINATOR" TYPE HEAD TRACK AT WALLS TERMINATING
THROUGH THE BASE BUILDING PREMISES AND ELEVATOR M.
AT CEILING. USE PREFORMED OUTSIDE CORNERS.
1
GENERAL REQUIREMENTS
2.10
CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES
AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY
9.2 GYPSUM BOARD: PROVIDE 5/8' THICK REGULAR AND TYPE 'X" TAPERED
1.1
WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS
SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE-
EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND
WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR
OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED
JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE
BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT.
CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO
WITH ASTM 0840 TO THE HIGHEST QUALITY STANDARDS.
1.2
THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK 8Y OTHERS
DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS
DATA, SECURELY, FURNITURE
INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA,
PLUMBING, HVAC, ELECTRICAL, AND FIRE PROTECTION SYSTEMS.
.1 DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED
AND "FURNISHED AND/OR INSTALLED" ITEMS. CONTRACTOR SHALL
CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A
INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH
COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING,
RECORD SEPIA TO SERVE AS PART OF THE AS -BUILT' SET.
MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA -
AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE
2,11
PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT,
216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND
WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR
SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE
FINISHING OF GYPSUM BOARD.
REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS.
DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN,
1.3
CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING
9.4 CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM
ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND
5
METAL FABRICATIONS
DAMAGED OR SOILED TILES.
WORKMANSHIP.
1.4
SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE
5.1
PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED
.1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS
FOLLOWING ITEMS:
OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS
IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL
REQUIRED TO COMPLETE WORK.
REFLECTED CEILING PLAN SHALL GOVERN.
1 METAL FABRICATIONS.
.2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN
.2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS.
6
WOOD AND PLASTIC
LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS
.3 DOORS, FRAMES AND HARDWARE.
UNLESS NOTED OTHERWISE.
.4 SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6' X 6' ACOUSTICAL
6.1
CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE "CONSTRUCTION
PANEL )•
GRADE" LUMBER OF ANY SPECIES WITH MAXIMUM 197. MOISTURE
9.5 INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR
.5 VCT FLOORING AND BASE ( COLOR SAMPLES ).
CONTENT.
CASED OPENING UNLESS NOTED OTHERWISE.
.6 CARPET ( DYE LOT CUTTING AND SEAMING DIAGRAMS ).
6.2
PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE
.7 PAINT (6" X 6" ON ACTUAL SURFACE ).
EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA
.1 INSTALL JOHNSONITE TRIM STRIPS AT DOOR WHERE CARPET
.8 ALINGS (9" X 9" DYE LOT CUTTING }.
C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32".
MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH
.9 SIGNAGE ( SAMPLE SIGN ).
LIGHT FIXTURES (CATALOG CUTS ).
6.3
FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND
CARPET.
.10
PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA
1.5
TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES,
C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH
9.6 RESILIENT FLOORING:
TEMPORARY ENCLOSURES, FIRE PROTECTION, HEAT AND POWER
CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING
JURISDICTION.
.1 UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS
WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR
6.4
FINISH CARPENTRY AND MILLWORK: COMPLY WITH "PREMIUM GRADE" AWI
ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT
THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING
STANDARDS.
OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO
CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S
AVOID USE OF CUT WIDTHS LESS THAN 3" AT ROOM PERIMETER.
AGENT.
PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR
•2 BASE: FIT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID
1.6
THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND
.1
TO FABRICATION OF MULTIPLE UNITS.
BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING
OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR
ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS.
SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS,
6.5
COUNTERS: NIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH
TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT
NEMA LD 3 AND GP -50 (0.050" NOMINAL THICKNESS).
9.7 USE AN APPROVED CEMENTITIOUS FILLER TO PATCH CRACKS, SMALL
EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE.
HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM
THE CONTRACT OR SHALL BE HELD RESPONSIBLE FOR DAMAGES
O
EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL
SURFACE VARIATION OF %" IN 10 FEET, NON -CUMULATIVE.
ATTRIBUTABLE HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT
.1
SURFACES.
ADDITIONAL CHARGE TO THE PARTY AFFECTED.
2 PROVIDE 2" DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE
1.7
THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS
CONTRACT EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES AND ALARMS
.
ELECTRICAL OR DATA OUTLET LOCATIONS.
9.8 CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING
TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS.
6.6
CABINETS: COMPLY WITH AWI SECTION 400 AND ITS DIVISION 4008 FOR
STANDARDS:
1.8
SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT
PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS.
FLAMMABILITY: ASTM 2859
PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED,
SUBMIT THE FOLLOWING INFORMATION:
SURFACE
SURFACE BURNING: ASTM E84
1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS:
SMOKE DENSITY: ASTM E662
PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF
GP -50 (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP -28
SOUND ABSORPTION: ASTM C423
.1
PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES.
(0.028" NOMINAL THICKNESS); EDGES: GP -28 (0.028" NOMINAL
FADE RESISTANCE: AATCC 16E
PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED.
THICKNESS).
STATIC RESISTANCE: AATCC 134
.2
PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL
.2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28.
WARRANTY: 10 YEARS
.3
CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO
.3 CABINET HARDWARE SCHEDULE:
ACCOMMODATE THE SUBSTITUTION.
1 HINGES: FULLY CONCEALED, SELF-CLOSING "1000 SERIES'
.1 INSTALL BROADLOOM CARPET BY DIRECT GLUE.
4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL
BY GRASS OR EQUAL.
AFFECT THE CONTRACT SUM AND CONTRACT TIME.
.2 PULLS: WIRE PROJECTING TYPE, DRILLING 4" ON CENTER,
1.9
STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TfME
#4483 OR EQUAL AS MANUFACTURED BY `TANLEY.
FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING.
.3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH
1.10
THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR
MINIMUM 8 LBS. PULL; # SP 45 OR SP 46 OR EQUAL AS
HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE
MANUFACTURED BY STANLEY.
BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN
.4 DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES
REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS.
WITH POSITIVE STOP AND LOCKOUT POSITION, WITH
HEAVY-DUTY FULL EXTENSION; #1429 OR EQUAL AS
MANUFACTURED BY KNAPE & VOGT.
.5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF
SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION
MOLDED NYLON AND WITH HEAVY DUTY TW4N SLOTTED
SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT
OR EQUAL.
INDIANAPOLIS, INDIANA
9.10 PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR
PROTECT HARDWARE, PLATES AND SIMILAR TRIM, AFTER PAINT IS DRY,
REINSTALL SUCH ITEMS.
.1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT
SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD
FOR THE VARIOUS SUBSTRATES, AS INDICATED.
1. FERROUS METAL:
A. ACRYLIC SEMI -GLOSS ENAMEL FINISH:
1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC
LATEX PRIMER.
2. FINISH: 2 COATS #83XX MfRROLAC-WB ACRYLIC
SEMI -GLOSS ENAMEL.
2. NON-FERROUS METAL:
A. ACRYLIC SEMI -GLOSS ENAMEL FINISH:
1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC
LATEX PRIMER.
2. FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC
SEMI -GLOSS FINISH
3. FERROUS STRUCTURE:
A. ACRYLIC DRY FOG FLAT FINISH:
1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER
REDUCIBLE ACRYLIC DtY FOG COATING
4. NON-FERROUS STRUCTURE:
A. ACRYLIC DRY FOG FLAT FINISH:
1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER
REDUCIBLE ACRYLIC DRY FOG COATING.
8. WOOD:
A. ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH:
1. PRIMER: 1 COAT #51701 WONDER -PRIME LATEX
PRIMER -SEALER.
2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC
SEMI -GLOSS ENAMEL.
B. STAIN -VARNISH RUBBED FINISH:
1. FILLER: 1 COAT #4800 WONDER WOODSTAIN
PASTE WOOD FILLER (OPEN GRAIN WOODS).
2. STAIN: 1 COAT 196XX WONDER WOODSTAIN
ALKYD STAIN.
3. SEALER: 1 COAT #4900 WONDER WOODSEALER
QUICK DRY SEALER.
4. FINISH: 2 COATS #4600 WONDER WOODSTAIN
ALKYD SATIN VARNISH.
10. GYPSUM WALLBOARD:
A. ACRYLIC LATEX SATIN ENAMEL FINISH:
1. PRIMER: 1 COAT #50801 WONDER TONES LATEX
PRIMER -SEALER.
2. FINISH: 2 COATS #35XX WONDER TONE ACRYLIC
LATEX SATIN ENAMEL.
13. PRECAST CONCRETE:
A. LATEX TEXTURE COATING -SAND FINISH (WET AREAS)
1, PRIMER: 1 COAT #1502 WONDER -SHIELD ACRYLIC
LATEX HOUSE PAINT TRIMER.
2. FINISH: 1 COAT #44101 DEV-VO-TEX LATEX
TEXTURE COATING.
9.11 WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTLI, CLEAN AND
WITHOUT WRINKLES, GAPS OR OVERLAPS.
.1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT
ACCEPTABLE
.2 SEAMS MUST BE AT LEAST 2" FROM INSIDE CORNERS AND 6' FROM
OUTSIDE CORNERS.
10 SPECIALTIES
10.1 FIRE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO
BUILDING STANDARD, PROVIDE JL INDUSTRIES "AMBASSADOR" SERIES,
SEMI RECESSED, DUO -PANEL, FIELD PAINTED.
12 FURNISHINGS
12.1 CASEWORK:
.1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE
FOLLOWING:
.1 IMPERIAL CABINET CO., INC.
.2 MERILLAT INDUSTRIES, INC.
.3 YORKTOWNE CABINETS
15/16 MECHANICAL AND ELECTRICAL z `"
15/16.1 MECHANICAL (INCLUDING PLUMBING, FIRE PROTECTION AND HVAC) AND
ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE < 3 Q x72
RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS
ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC
CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL
BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE,
INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND
ELECTRICAL SYSTEMS.
15/16.2 GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF
DESIGN/BUILD DRAWINGS FOR FIRE PROTECTION, MECHANICAL, AND
PLUMBING, SIGNET} AND STAMPED FOR STATE FILING PROCESS BY A
CERTIFIED ENGINEER.
15/16.3 IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S
DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS
DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) ��d0
AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL CF-
DRAWINGS
eDRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AN1
OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH W
15/16.4 SUBMIT FIRE SPRINKLER LAYOUT FOR COORDINATION/APP No &5�a
OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKL O 4
SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND LL .t c G44
COORDINATE WITH OTHER CEILING COMPONENTS.
15/16.5 DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS
SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR, ���'
OWNERS AGENT.
15/16.6 OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED, •.
WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED.
VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED
EQUIPMENT.
15/16.7 SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE
GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER.
15/16.8 DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND
INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL
COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND
TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE
INSTALLATION SHALL OCCUR.
15/16.9 DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF
OUTLETS, UNLESS OTHERWISE NOTED.
15/16.10 ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD
COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE
IVORY.
15/16.11 WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY
SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL
PROVIDING PROPER ACCESS TO RECEPTACLES.
15/16.12 IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL
FOR SPECIFIC LOCATION.
15/16.13 CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET
LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO
OBSERVE PRIOR TO ANY COMMENCEMENT OF 'ROUGH -IN"
CONSTRUCTION.
GN GENERAL NOTES
GN.1 CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND
REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO
PROCEEDING WITH CONSTRUCTION.
GN.2 DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED:
A TO FINISHED FACE OF GYPSUM BOARD,
B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS.
C. TO TOP OF FINISHED FLOORS.
D. TO BOTTOM OF FINISHED CEILINGS.
GN.3 SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION,
EXISTING CONSTRUCTION AND WALL TYPES.
GNA TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED
OTHERWISE.
GN.5 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION
LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS
SHALL BE AS SHOWN ON CONSTRUCTION PLAN, IN CASE OF CONFLICT,
NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING
WITH CONSTRUCTION.
GN.6 CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT
FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT.
DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS
OBSERVATION,
GN.7 FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT
LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT
FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4" IN 20'-0' NON-
CUMULATIVE, NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED.
GN.8 CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO
CLOSE -IN OF WALLS,
GNA SOUND INSULATED AND FIRE RATED PARTITIONING SHALL BE CAULKED AT
PERIMETER WITH ACOUSTICAL OR FIRE RATED SEALANT AS APPLICABLE.
PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE.
PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED
TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL
JUNCTION BOXES ARE NOT PERMITTED.
GN.10 ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY
CONTRACTOR.
.�``'N R. TU fo
c .F•p
f No.
AR00910036
�. STATE OF
!.� H` I! oq
�0
X" `r
M��
W
06/20/03
CSO #23087 �,
C
F
N.
Z
w N
Q
15
zg
7�
�
C r' C
• �i.l s
U
. �
v
Ri � u
o =
a
z
U
° j
�•
Ute;.
z
v v
g �oyv
Y
40_�
y
E
>
15/16 MECHANICAL AND ELECTRICAL z `"
15/16.1 MECHANICAL (INCLUDING PLUMBING, FIRE PROTECTION AND HVAC) AND
ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE < 3 Q x72
RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS
ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC
CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL
BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE,
INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND
ELECTRICAL SYSTEMS.
15/16.2 GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF
DESIGN/BUILD DRAWINGS FOR FIRE PROTECTION, MECHANICAL, AND
PLUMBING, SIGNET} AND STAMPED FOR STATE FILING PROCESS BY A
CERTIFIED ENGINEER.
15/16.3 IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S
DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS
DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) ��d0
AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL CF-
DRAWINGS
eDRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AN1
OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH W
15/16.4 SUBMIT FIRE SPRINKLER LAYOUT FOR COORDINATION/APP No &5�a
OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKL O 4
SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND LL .t c G44
COORDINATE WITH OTHER CEILING COMPONENTS.
15/16.5 DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS
SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR, ���'
OWNERS AGENT.
15/16.6 OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED, •.
WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED.
VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED
EQUIPMENT.
15/16.7 SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE
GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER.
15/16.8 DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND
INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL
COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND
TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE
INSTALLATION SHALL OCCUR.
15/16.9 DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF
OUTLETS, UNLESS OTHERWISE NOTED.
15/16.10 ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD
COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE
IVORY.
15/16.11 WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY
SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL
PROVIDING PROPER ACCESS TO RECEPTACLES.
15/16.12 IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL
FOR SPECIFIC LOCATION.
15/16.13 CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET
LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO
OBSERVE PRIOR TO ANY COMMENCEMENT OF 'ROUGH -IN"
CONSTRUCTION.
GN GENERAL NOTES
GN.1 CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND
REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO
PROCEEDING WITH CONSTRUCTION.
GN.2 DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED:
A TO FINISHED FACE OF GYPSUM BOARD,
B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS.
C. TO TOP OF FINISHED FLOORS.
D. TO BOTTOM OF FINISHED CEILINGS.
GN.3 SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION,
EXISTING CONSTRUCTION AND WALL TYPES.
GNA TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED
OTHERWISE.
GN.5 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION
LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS
SHALL BE AS SHOWN ON CONSTRUCTION PLAN, IN CASE OF CONFLICT,
NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING
WITH CONSTRUCTION.
GN.6 CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT
FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT.
DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS
OBSERVATION,
GN.7 FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT
LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT
FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4" IN 20'-0' NON-
CUMULATIVE, NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED.
GN.8 CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO
CLOSE -IN OF WALLS,
GNA SOUND INSULATED AND FIRE RATED PARTITIONING SHALL BE CAULKED AT
PERIMETER WITH ACOUSTICAL OR FIRE RATED SEALANT AS APPLICABLE.
PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE.
PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED
TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL
JUNCTION BOXES ARE NOT PERMITTED.
GN.10 ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY
CONTRACTOR.
.�``'N R. TU fo
c .F•p
f No.
AR00910036
�. STATE OF
!.� H` I! oq
�0
X" `r
M��
W
06/20/03
CSO #23087 �,