Loading...
HomeMy WebLinkAbout03080109.3FUTURE====________________ II CORRIDOR II 403 II I� II I I I I I I �I )OR II II II II CONSTRUCTION PLAN SCALE: 1/8" = 1'-0" NORTH GENERAL CONSTRUCTION NOTES.- A. OTES: A. DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY DESIGNER- DO NOT SCALE DRAWINGS. B. REFER TO CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES. C. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL. D. ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE PATCHED, REPAIRED AND SANDED SMOOTH IN PREPARTION FOR NEW FINISHES. E. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. F. ALL NEW AND EXISTING FIRE EXTINGUISHER CABINETS TO BE INSTALLED ACCORDING TO CODE. LIFSAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER LOCATIONS ARE NEEDED A PLAN MUST BE SUBMITTED TO THE DESIGNER FOR REVIEW OF AESTHETIC PURPOSES ONLY. x WALL LEGEND: NOTES: EXISTING PARTITION TO REMAIN NEW WALL PARTITION W1 2-1/2- 25 GAUGE METAL STUDS @24-O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. W2 2-1/2" 25 GAUGE METAL STUDS @24"O.C. WITH 5/8" GYPSUM WALL BOARD EACH r) T SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. PROVIDE 2 1/2" SOUND INSULATION IN HORIZONTAL SURFACE ABOVE CEILING AND INSIDE WALL. INSULATION TO EXTEND 2'-0" IN BOTH DIRECTIONS FROM CENTER LINE OF WALL. DENOTES AREA NOT IN CONTRACT DENOTES NEW MILLWORK o NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE IF FUTURE CORRIDOR �) 403 I I I I I I I II I I I I )OR II II II II REFLECTED CEILING PLAN SCALE: I/8" = 1'-0" NORTH CONSTRUCTION PLAN NOTES: FP1 ALIGN FINISHED FACES. FP2 CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS USE SEALANT AT MULLIONS FOR SOUND INSULATION. VERIFY DIMENSION FROM MULLION TO MULLION AND REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING WITH CONSTRUCTION. REFERENCE DETAIL 1/4A201. FP3 NEW RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION WITH TOP OF CABINET AT 54" AFF. FP4 PROVIDE 1/4" COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED ICE MAKER/REFRIGERATOR AND COFFEEMAKER. VERIFY EXACT LOCATION OF ALL APPLIANCES, REQUIRING A WATER SOURCE WITH TENANT. FPs PROVIDE COAT ROD AND SHELF; REFERENCE DETAIL 2/4A201. FPs COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MFG. MANUAL. UNDERCOUNTER GARBAGE DISPOSAL TO BE PROVIDED AND INSTALLED BY G.C. G.C. TO PROVIDE POWER SOURCE FPR GARBAGE DISPOSAL. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURERS MANUAL. OREFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER GENERAL CEILING NOTES: REFLECTED CEILING LEGEND: A. ALL WALLS GO TO BOTTOM OF CEILING UNLESS OTHERWISE NOTED. ]= B. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO NEW 2' X 4' FLUORESCENT FIXTURE, TO MATCH BUILDING STANDARD ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY ARE TO BE CONSOLODATED TO A GANG PLATE CONDITION. C. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY �'_*i NEW DOWNLIGHT FIXTURE, DESCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. D. MECHANICAL AND ELECTRICAL IS DESIGN -BUILD. DESIGN -BUILD CONTRACTOR 1-� NEW WALL WASHER FIXTURE TO BE BUILDING STANDARD u � TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, NEW CEILING MTD. EXIT LIGHT W1 DIRECTION INDICATION EMERGENCY NIGHT LIGHTS AND THERMOSTATS. DESIGN -BUILD CONTRACTOR TO 1*E DUAL-LITE, SEE XXXXX FOR SPECIFICATION COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR EXISTING 2 X 2 LAY -IN GRID SUSPENSION SYSTEM TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. � E. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL NEW TWO WAY SWITCH SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT $ NEW DIMMER SWITCH OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY D CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND $3 NEW THREE-WAY SWITCH OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW AND COORDINATION NL NIGHTLIGHT LOCATION OF LOCATION OF DEVICES. CSO INTERIORS REVIEW IS FOR ASTHETIC REVIEW ONLY. F. REPLACE ANY DAMAGED OR MISSING CEILING TILES. NEW TILES TO MATCH EXISTING. GENERAL CONTRACTOR TO VERIFY EXISTING GRID LAYOUT AND CONDITION. G. PATCH, REPAIR, AND/OR REPLACE CEILING GRID SYSTEM WHERE WALLS, LIGHT FIXTURES, OR PARTITIONS HAVE BEEN REMOVED. CEILING GRID SYSTEM TO BE RESTORED TO MATCH EXISTING ADJACENT CONDITION AS TO NOT SHOW LINE OF DEMOLITION. H. RE -USE EXISTING LIGHT FIXTURES WHERE SHOWN. STORE SALVAGED LIGHT FIXTURES DURING THE CONSTRUCTION PHASE. STORAGE OF SALVAGED FIXTURES TO BE COORDINATED WITH OWNER, FIXTURES TO BE CLEANED, RELAMPED, AND INSTALLED UPON COMPLETION OF CONSTRUCTION. I. CEILING HEIGHT IS 9'-0" A.F.F. UNLESS OTHERWISE NOTED. I ,r CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Six Parkwood Office 600 East 96th Street, Suite 550 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 01(-pv69ht 2001 0 0 nm cm N ms V (/ O o U z a J a 0 z J W V 0 W Q Q V Q J 0 = o �:0z W W W q�d L — CC cc V Q W J 06 O a�a z (� V) z 0 Q � r�� V Z W — F— z 0 0 w 0 0 0 U Certified By: `�,.%```N R. T I �•,,�� 4�� Q• P��IST e $ No. Z AR00910036 STATE OF CHII r Drawing Number: 4A202 Of Sheets Duke Job Number: A/E Job Number: 23087 I ,r