Loading...
HomeMy WebLinkAbout03080152.1TACTE �Y, 1 N C SEVEN PARKWOOD SPECIFICATIONS AND GENERAL NOTES 0 0.1 ARCHITECT: kkamcso 600 E. 96TH STREET, SUITE 550 i LPA INDIANAPOLIS, INDIANA 46240 (317) 848.7800 (317) 574.1869 FAX 0.2 CONTRACTOR: 0.3 44WA Duke RNWTION 4225 NAPERVILLE ROAD SUITE 150 LSILE, IL 60532 PHONE: (630)577-7900 C1 moo °O� h�0R f p7' pFstwe ana ancc_ S�R�IJ OP .;01 P INDEX OF DRAWINGS ❑ ,wvw�n ks sue�rtrhn ❑ ,aPawtn a raim ❑cim KEYPLAN SCALE: NOT TO SCALE NORTH 0.4 0.5 0.6 0.7 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 CONTRACT CONDITIONS THE GENERAL CONDMONS SHALL BE AIA DOCUMENT A201 - 1987 EDITION, ENTITLED "GENERAL CONDMONS OF THE CONTRACT FOR CONSTRUCTION'. THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE RESPONS181LMES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED AS FOLLOWS: 3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE PROCEEDING WITH CONSTRUCTION. 3.3 SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. 3.7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY GOVERNMENTAL FEES, LICENSES AND INSPECTIONS. 3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND WORKMANSHIP. 10.1 INMATE, MAINTAIN AND SUPERVISE PROJECT SAFETY PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES, RULES AND REGULATIONS. ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED PROJECT. WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE SPECIFIED CAPACITIES OF THE EQUIPMENT. WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL GOVERN THE WORK. NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S INTERPRETATION. INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. GENERAL REQUIREMENTS WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT. THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURITY, FURNITURE AND 'FURNISHED AND/OR INSTALLED' ITEMS. CONTRACTOR SHALL COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING, AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS. CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP. SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE FOLLOWING ITEMS: .1 METAL FABRICATIONS. .2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS. .3 DOORS, FRAMES AND HARDWARE. .4 SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6' X 6' ACOUSTICAL PANEL ). .5 VCT FLOORING AND BASE ( COLOR SAMPLES ). .6 CARPET ( DYE LOT CUTTING AND SEAMING DIAGRAMS ). .7 PAINT ( 6' X 6' ON ACTUAL SURFACE ). .8 WALLCOVERINGS ( 9' X 9' DYE LOT CUTTING ). .9 SIGNAGE ( SAMPLE SIGN ). .10 LIGHT FIXTURES ( CATALOG CUTS ). TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES, TEMPORARY ENCLOSURES, FIRE PROTECTION, HEAT AND POWER WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING CONSTRUCTION RULES PUBUSHED BY THE OWNER OR THE OWNER'S AGENT. THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS, TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT ADDITIONAL CHARGE TO THE PARTY AFFECTED. THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS CONTRACT EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES AND ALARMS TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS. SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED, SUBMIT THE FOLLOWING INFORMATION: .1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES. .2 PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED. .3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO ACCOMMODATE THE SUBSTITUTION. .4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTMAON WILL AFFECT THE CONTRACT SUM AND CONTRACT TIME. STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELUNG. THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS. 1.12 2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 5 5.1 6 6.1 6.2 6.3 6.4 6.5 6.6 SUITE 175 PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD. COORDINATE DEMOLITION WITH CONSTRUCTION PLANS TO DETERMINE EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW WORK. WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLPCEMENT, OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR ADDITIONAL WORK RELATED TO SUCH ACTIVITIES. WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL BE INCLUDED. REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE DRAWINGS. ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW FINISHES. EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR NOTED TO BE REPAIRED. SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS. REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK IN SCOPE OF CONTRACT. PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC, CARPET MATS SHALL BE LARGE ENOUGH TO PREVENT THE HAUUNG/SPREADING OF DIRT THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS. CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE - OFF LMUTY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS PLUMBING, HVAC, ELECTRICAL, AND FIRE PROTECTION SYSTEMS. CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A RECORD SEPIA TO SERVE AS PART OF THE "AS -BUILT' SET. PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT, SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN. METAL FABRICATIONS PROVIDE STEEL FRAMING AND SUPPORTS FOR APPUCATIONS INDICATED OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS REQUIRED TO COMPLETE WORK. WOOD AND PLASTIC CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE 'CONSTRUCTION GRADE" LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE CONTENT. PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32'. FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. FINISH CARPENTRY AND MILLWORK: COMPLY WITH 'PREMIUM GRADE' AWI STANDARDS. .1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR TO FABRICATION OF MULTIPLE UNITS. COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH NEMA LD 3 AND GP -50 (0.050" NOMINAL THICKNESS). .1 EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL SURFACES. .2 PROVIDE 2' DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE ELECTRICAL OR DATA OUTLET LOCATIONS. CABINETS: COMPLY WITH AWI SECTION 400 AND ITS DIVISION 400B FOR PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS. .1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS: GP -50 (0.050' NOMINAL THICKNESS); VERTICAL SURFACES: GP -28 (0.028' NOMINAL THICKNESS); EDGES: GP -28 (0.028' NOMINAL THICKNESS). .2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28. .3 CABINET HARDWARE SCHEDULE: .1 HINGES: FULLY CONCEALED, SELF-CLOSING '1000 SERIES' BY GRASS OR EQUAL .2 PULLS: WIRE PROJECTING TYPE, DRILLING 4' ON CENTER, 14483 OR EQUAL AS MANUFACTURED BY STANLEY. .3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WMH MINIMUM 8 LBS. PULL; # SP 45 OR SP 46 OR EQUAL AS MANUFACTURED BY STANLEY. .4 DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES WITH POSITIVE STOP AND LOCKOUT POSITION, WITH HEAVY-DUTY FULL EXTENSION; 11429 OR EQUAL AS MANUFACTURED BY KNAPE & VOGT. .5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT OR EQUAL INDIANAPOLIS, INDIANA 6.7 MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDMONS. 6.8 DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING, WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY OPERATING FOR TEN DAYS. 6.9 INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS. 6.10 JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM WIDTH NOT TO EXCEED 1/8 U.O.N. 6.11 GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL OUTLETS. 7 JOINT SEALERS 7.1 ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS AND FIXTURES: .1 'DOW CORNING 786'; DOW CORNING CORP. .2 'SCS 1702 SANITARY'; GENERAL ELECTRIC CO. .3 '863 1345 WHITE"; PECORA CORP. .4 "PROGLAZE WHITE"; TREMCO CORP. .5 'OMNIPLUS'; SONNEBORN BUILDING PRODUCTS 7.2 ACRYUC-EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING SURFACES: .1 'CHEM -CALK 600"; BOSTIK CONSTRUCTION PRODUCTS DIV, .2 'AC -20'; PECORA CORP. .3 'SONOLAC'; SONNEBORN BUILDING PRODUCTS .4 'TREMCO ACRYLIC LATEX 834"; TREMCO, INC. 8 DOORS AND WINDOWS 8.1 INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER. 8.2 INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH. 8.3 DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH AND LOCKSETS. 8.4 GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 REQUIREMENTS FOR HEAT -STRENGTHENED GLASS. 9 FINISHES 9.1 GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645. ,1 INSTALL 'EUMINATOR' TYPE HEAD TRACK AT WALLS TERMINATING AT CEILING. USE PREFORMED OUTSIDE CORNERS. 9.2 GYPSUM BOARD: PROVIDE 5/8" THICK REGULAR AND TYPE 'X' TAPERED EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS. .1 DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA - 216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND FINISHING OF GYPSUM BOARD. 9.4 CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM DAMAGED OR SOILED TILES. .1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL REFLECTED CEIUNG PLAN SHALL GOVERN. .2 CENTER CEIUNG ELEMENTS IN CEILING TILE, INCLUDING DOWN LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS UNLESS NOTED OTHERWISE. 9.5 INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR CASED OPENING UNLESS NOTED OTHERWISE. .1 INSTALL JOHNSONITE TRIM STRIPS AT DOOR WHERE CARPET MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH CARPET. 9.6 RESILIENT FLOORING: .1 UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO AVOID USE OF CUT WIDTHS LESS THAN 3' AT ROOM PERIMETER. .2 BASE: FIT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. 9.7 USE AN APPROVED CEMENTMOUS FILLER TO PATCH CRACKS, SMALL HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM SURFACE VARIATION OF V IN 10 FEET, NON -CUMULATIVE. 9.8 CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING STANDARDS: FLAMMABILITY: ASTM 2859 SURFACE BURNING: ASTM E84 SMOKE DENSITY: ASTM E662 SOUND ABSORPTION: ASTM C423 FADE RESISTANCE: AATCC 16E STATIC RESISTANCE: AATCC 134 WARRANTY: 10 YEARS .1 INSTALL BROADLOOM CARPET BY DIRECT GLUE. 9.10 PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY, REINSTALL SUCH ITEMS. .1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD FOR THE VARIOUS SUBSTRATES, AS INDICATED. 1. FERROUS METAL A ACRYUC SEMI -GLOSS ENAMEL FINISH: 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC LATEX PRIMER. 2. FINISH: 2 COATS 183XX MIRROLAC-WB ACRYLIC SEMI -GLOSS ENAMEL. 2. NON-FERROUS METAL A ACRYLIC SEMI -GLOSS ENAMEL FINISH: 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC LATEX PRIMER. 2. FINISH: 2 COATS 183XX MIRROLACE-WB ACRYUC SEMI -GLOSS FINISH 3. FERROUS STRUCTURE: A. ACRYLIC DRY FOG FLAT FINISH: 1. FINISH: 2 COATS 157601 UNI -GRIP -WB WATER REDUCIBLE ACRYLIC DRY FOG COATING 4. NON-FERROUS STRUCTURE: A. ACRYLIC DRY FOG FLAT FINISH: 1. FINISH: 2 COATS 157601 UNI -GRIP -WB WATER REDUCIBLE ACRYLIC DRY FOG COATING. 8. WOOD: A. ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH: 1. PRIMER: 1 COAT #51701 WONDER -PRIME LATEX PRIMER -SEALER. 2. FINISH: 2 COATS 183XX MIRROLAC-WB ACRYLIC SEMI -GLOSS ENAMEL B. STAIN -VARNISH RUBBED FINISH: 1. FILLER: 1 COAT 14800 WONDER WOODSTAIN PASTE WOOD FILLER (OPEN GRAIN WOODS). 2. STAIN: 1 COAT #96XX WONDER WOODSTAIN ALKYD STAIN. 3. SEALER: 1 COAT #4900 WONDER WOODSEALER QUICK DRY SEALER. 4. FINISH: 2 COATS #4660 WONDER WOODSTAIN ALKYD SATIN VARNISH. 10. GYPSUM WALLBOARD: A ACRYLIC LATEX SATIN ENAMEL FINISH: 1. PRIMER: 1 COAT #50801 WONDER TONES LATEX PRIMER -SEALER. 2. FINISH: 2 COATS #35XX WONDER TONE ACRYLIC LATE( SATIN ENAMEL 13, PRECAST CONCRETE: A. LATEX TEXTURE COATING -SAND FINISH (WET AREAS) 1. PRIMER: 1 COAT 11502 WONDER -SHIELD ACRYLIC LATEX HOUSE PAINT PRIMER. 2. FINISH: 1 COAT #44101 DEV-VO-TEX LATEX TEXTURE COATING. 9.11 WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, CLEAN AND WITHOUT WRINKLES, GAPS OR OVERLAPS. .1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT ACCEPTABLE. 2 SEAMS MUST BE AT LEAST 2' FROM INSIDE CORNERS AND 6' FROM OUTSIDE CORNERS. 10 SPECIALTIES 10.1 FIRE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO BUILDING STANDARD, PROVIDE JL INDUSTRIES "AMBASSADOR' SERIES, SEMI RECESSED, DUO -PANEL, FIELD PAINTED. 12 FURNISHINGS 12.1 CASEWORK: 1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: .1 IMPERIAL CABINET CO., INC. .2 MERILLAT INDUSTRIES, INC. .3 YORKTOWNE CABINETS 15/16 MECHANICAL AND ELECTRICAL 15/16.1 MECHANICAL (INCLUDING PLUMBING, FIRE PROTECTION AND HVAC) AND ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND ELECTRICAL SYSTEMS. 15/16.2 GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF DESIGN/BUILD DRAWINGS FOR FIRE PROTECTION, MECHANICAL, AND PLUMBING, SIGNED AND STAMPED FOR STATE RUNG PROCESS BY A CERTIFIED ENGINEER. 15/16.3 IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK. 15/16.4 SUBMIT FIRE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL COORDINATE WITH OTHER CEIUNG COMPONENTS. 15/16.5 DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR OWNER'S AGENT. 15/16.6 OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED. VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED EQUIPMENT. 15/16.7 SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. 15/16.8 DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE INSTALLATION SHALL OCCUR. 15/16.9 DIMENSIONS, IF IDENTIFIED, ARE TO CENTERUNE OF OUTLET OR GANG OF OUTLETS, UNLESS OTHERWISE NOTED. 15/16.10 ALL SWITCHES AND SWTTCHPLATES SHALL BE BUILDING STANDARD COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE IVORY. 15/16.11 WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL PROVIDING PROPER ACCESS TO RECEPTACLES. 15/16.12 IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL FOR SPECIFIC LOCATION. 15/16.13 CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO OBSERVE PRIOR TO ANY COMMENCEMENT OF 'ROUGH -IN' CONSTRUCTION. GN GENERAL NOTES GN.1 CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDMONS AND REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO PROCEEDING WITH CONSTRUCTION. GN.2 DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: A. TO FINISHED FACE OF GYPSUM BOARD. B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS, C. TO TOP OF FINISHED FLOORS. D. TO BOTTOM OF FINISHED CEIUNGS. GN.3 SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION, EXISTING CONSTRUCTION AND WALL TYPES. GNA TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED OTHERWISE. GN.5 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS SHALL BE AS SHOWN ON CONSTRUCTION PLAN, IN CASE OF CONFLICT, NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH CONSTRUCTION. GN.6 CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT. DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS OBSERVATION. GN.7 FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4" IN 20'-0' NON- CUMULATVE, NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED. GN.8 CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO CLOSE -IN OF WALLS. GN.9 SOUND INSULATED AND FIRE RATED PARTITIONING SHALL BE CAULKED AT PERIMETER WITH ACOUSTICAL OR ARE RATED SEALANT AS APPLICABLE. PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL JUNCTION BOXES ARE NOT PERMITTED. GN.10 ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY CONTRACTOR. S`yg39? ir R. T�7��� ^ll O �b ti's' •�Gis t �R. `.�.) f✓ No. AR00910036 STATE OF z 1 - 08/22/03 CSO #23334