Loading...
HomeMy WebLinkAbout17080001 Building Plans ARCHITECTS FORUM SUB ZERO ICE CREAM 301 PENNSYLVANIA PARKWAY, SUITE 155 1719 N. UNIVERSITY PKWY, SUITE 201 INDIANAPOLIS, IN 46280 PROVO, UT 84606 \[P\] 317.842.8500 \[P\] 385.208.4353 \[F\] 317.842.8877 SEATING 100 10"-0" CODE REQUIREMENTSSHEET INDEX 9'-4" ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE 9'-0" COVER TITLESHEET / CODE REQUIREMENTS PROVISIONS OF THE SPECIFICATIONS & DRAWINGS AND SHALL SATISFY ALL APPLICABLE CODES, ORDINANCES, A.D.A., AND CIVIL REGULATIONS OF ALL GOVERNING BODIES INVOLVED. SERVICE 101 NOT REQUIRED 10'-0" ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE CONTRACTOR INVOLVED. STRUCTURAL NOT REQUIRED THE FOLLOWING CODES AND REGULATIONS ARE CURRENTLY PREP 102 ADOPTED BY THE STATE OF INDIANA AT THE TIME A BUILDING 10'-0" ARCHITECTURAL A100 DEMOLITION PLAN & FLOOR PLAN BUILDING CODE: INDIANA BUILDING CODE 2008 A200 REFLECTED CEILING PLAN & FINISH PLAN (INTERNATIONAL BUILDING CODE 2006 A300 EQUIPMENT PLAN & ENLARGED PLAN WITH INDIANA AMENDMENTS) A400 INTERIOR ELEVATIONS & DETAILS FE PREP MECHANICAL CODE: INDIANA MECHANICAL CODE 2008 E100 ELECTRICAL PLAN 103 10'-0" (INTERNATIONAL MECHANICAL CODE 2006 WITH INDIANA AMENDMENTS) PREP RESTROOM 104 105 10'-0" 9'-0" ELECTRICAL CODE: INDIANA ELECTRICAL CODE 2009 (NATIONAL ELECTRICAL CODE 2008 WITH INDIANA AMENDMENTS) PLUMBING CODE: INDIANA PLUMBING CODE 1999 (UNIFORM PLUMBING CODE 1997) FIRE CODE: INDIANA FIRE CODE 2008 (INTERNATIONAL FIRE CODE 2006 WITH INDIANA AMENDMENTS) ENERGY CODE: INDIANA ENERGY CONSERVATION CODE 2010 (ASHRAE 90.1-2007 WITH INDIANA AMENDMENTS) FUEL GAS CODE: INDIANA FUEL GAS CODE 2008 (INTERNATIONAL FUEL GAS CODE 2006 WITH INDIANA AMENDMENTS) ACCESSIBILITY CODE: INDIANA BUILDING CODE, CHAPTER 11 ICC/ANSI A117.1-1998 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES AND N.J.A.C. 5:23-7 BARRIER FREE SUBCODE CODE SUMMARYPROJECT LOCATION TYPE II-B EXISTING FULLY SPRINKLERED 1,330 SQ. FT. LIFE SAFETY FLOOR PLAN MIXED USE OCCUPANCY: SCALE = 3/32" = 1'-0" GROUP A-2 ASSEMBLY & GROUP S-2 STORAGE OCCUPANT LOAD CALCULATION EXISTING GROUP A2 ASSEMBLY = 600 SF / 15 = 40 EXISTING GROUP S2 STORAGE = 730 SF / 200 = 4 TOTAL OCCUPANTS = 44 REQUIREDPROVIDED TENANT 44 OCCUPANTS X .15" 6.6" 72" MAP N NOT TO SCALE GENERAL PLAN NOTESGENERAL DEMOLITION NOTES ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH A. A.COORDINATE EXTENT OF DEMOLITION WORK WITH ALL NEW ALL APPLICABLE CODES, LAWS AND ORDINANCES. CONSTRUCTION, AS INDICATED IN CONTRACT DOCUMENTS. ALL DIMENSIONS ARE FROM FACE OF STUD, OR COLUMN CENTERLINE. B. B.THESE DEMOLITION NOTES REPRESENT SURVEYED SPACES ANY DIMENSIONS NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BEFORE DEMOLITION WORK. LOCATION OF CASEWORK, BE VERIFIED BY ARCHITECT. DO NOT SCALE DRAWINGS. COUNTERS, ETC. WITHIN THESE DOCUMENTS MAY NOT BE COMPLETELY ACCURATE. C.CONTACT RESPECTIVE UTILITY COMPANY FOR EXACT LOCATION OF SERVICES PRIOR TO START OF CONSTRUCTION. PROTECT ANY C.FIELD VERIFY EXACT SIZES AND LOCATION OF ALL EXISTING WORK EXISTING SERVICE DURING CONSTRUCTION. PRIOR TO CONSTRUCTION. CONTACT THE ARCHITECT IN THE COORDINATE WORK OF THIS TRADE WITH OTHER TRADES. D. EVENT OF CONFLICTS. E.REFERENCE MEP DRAWINGS FOR ALL MECHANICAL, D.CONTRACTOR SHALL PROVIDE ALL TEMPORARY PARTITIONS AND PLUMBING AND ELECTRICAL REQUIREMENTS. DOORS AS DEEMED NECESSARY BY ARCHITECT AND OWNER TO AVOID MIGRATION OF DUST INTO ADJOINING AND OCCUPIED SEE WALL TYPE LEGEND FOR WALL CONSTRUCTION. F. AREAS. 01 G.PROVIDE FIRE TREATED WOOD BLOCKING SUPPORT AT ALL SURFACE 14 E.MAKE ALL DEMOLITION CLEAN AND COMPLETE AND IN A MANNER A400 MOUNTED ITEMS AS REQUIRED. SUITABLE TO ACCEPT NEW FINISHES AND/OR SURFACES. DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. H. F.ALL DEMOLITION ITEMS SHALL BE CONSIDERED PROPERTY OF THE WHERE MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX 19 E X OWNER UNTIL VERIFICATION HAS BEEN MADE AS TO ITEMS TO BE I S HAS BEEN ADDED (I.E. 1000A). REFERENCE DOOR SCHEDULE. T I N RETAINED, PRIOR TO REMOVAL FROM THE SITE. ALL ITEMS NOT TO G CAULK ALL JUNCTURES BETWEEN DIFFERENT MATERIALS - TYPICAL. J. BE RETAINED SHALL BE REMOVED FROM THE SITE BY THE (I.E. STOREFRONT AND GYPSUM WALLBOARD). CONTRACTOR. 2 ALL STEEL STUDS ARE TO BE BRACED ACCORDING TO K. G.WHEN DEMOLITION CAUSES OR EXPOSES DAMAGE TO EXISTING MANUFACTURER'S LIMITING HEIGHT L/ OVER 240. SLAB, FLOOR, WALL OR CEILING SURFACES WHICH WILL REMAIN EXPOSED IN THE FINISHED WORK, THE CONTRACTOR SHALL ALL METAL STUD WALLS WHICH EXTEND TO DECK SHALL BE L. REPAIR AND LEVEL SUCH CONDITIONS AS REQUIRED. CONSTRUCTED WITH A CONTINUOUS SLIP TRACK AT TOP OF WALL. TRACK SHALL BE SIZED TO ALLOW FOR MINIMUM DECK DEFLECTION H.REMOVE EXISTING FLOOR, WALL AND CEILING FINISHES WHERE 15 OF 1/2". INDICATED. PROTECT ALL EXISTING INTERIOR FINISHES TO 8 REMAIN. M. EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES, ETC. AS REQUIRED BY LAW, CODE OR ORDINANCE AND AS OTHERWISE I.WHERE ANY EXISTING PIPING OR DUCTWORK IN FLOORS, WALLS REQUIRED. OR CEILINGS IS TO BE REMOVED OR RELOCATED, FILL IN N. REMOVE ALL TRASH AND DEBRIS FROM THE JOB SITE DAILY. PENETRATION OPENINGS FLUSH WITH AND OF THE SAME MATERIALS. O. PROVIDE WALL MOUNTED FIRE EXTINGUISHERS AND/OR CABINETS AS REQUIRED BY LOCAL CODE. J.REMOVAL OF ANY ASBESTOS IS THE RESPONSIBILITY OF THE OWNER. NOTIFY THE ARCHITECT IF SUCH MATERIAL IS P. ALL EQUIPMENT SHOWN FOR REFERENCE ONLY. EQUIPMENT TO BE DISCOVERED DURING DEMOLITION OPERATIONS. 15 PROVIDED BY TENANT. 88 K.DASHED LINES INDICATE TO REMOVE WALLS, DOORS, FRAMES AND Q. EXISTING HVAC UNIT AND DUCTWORK ABOVE TO BE REUSED. ASSOCIATED ITEMS COMPLETE. R. REFER TO EQUIPMENT PLAN 1/A300 FOR EQUIPMENT LOCATIONS AND INFORMATION. 17 5 4 SEATING 20 100 DEMOLITION PLAN NOTES PLAN NOTES 10"-0" REMOVE EXISTING WALL CONSTRUCTION COMPLETE.PATCH AND 1 SERVICE COUNTER TO BE INSTALLED AT 36" AFF. BLACK GRANITE 1 REPAIR ALL EXISTING SURFACES TO REMAIN AS REQUIRED. COUNTERTOP WITH S.S. FRAM AND SHELVING BELOW. REFER TO 8/A400 FOR MORE INFORMATION. 2 EXISTING DOOR AND FRAME TO REMAIN. PROTECT DURING ALL PHASES OF CONSTRUCTION. 24" D. BACK S.S. COUNTER WITH S.S. 4"BACKSPLASH AND S.S. BASE 2 CABINET. 02 3 EXISTNG PLUMBING FIXTURES TO REMAIN. PROTECT DURING ALL A400 PHASES OF CONSTRUCTION. 3 NOT USED. 54 4 REMOVE EXISTING FLOOR MATERIAL AND WALL BASE COMPLETE. 3'-6" 4 LN2 S.S. TANK PROVIDED BY TENANT, INSTALLED BY G.C. 5 EXISTING ACOUSTICAL CEILING TILE, GRID SYSTEM, LIGHT FIXTURES COORDINATE WITH TENANT AS REQUIRED. AND DIFFUSERS TO REMAIN. PROTECT DURING ALL PHASES OF CONSTRUCTION. 5 PROVIDE S.S. PLATE AT FLOOR OF STAINLESS STEEL TANK AS 8 1 REQUIRED. 6 EXISTING ELECTRICAL PANEL TO REMAIN. PROTECT DURING ALL 3'-6" PHASES OF CONSTRUCTION. PROVIDE WATER SUPPLY VALVES AND DRAINS AT DIPPING WELLS 6 AS REQUIRED TO ACCOMMODATE EQUIPMENT. REFER TO 7 EXISTING MOP SINK TO BE REMOVED. PATCH AND REPAIR EXISTING ENLARGED COUNTERTOP PLAN 2/A300. SURFACES TO REMAIN AS REQUIRED. 7 PROVIDE WATER LINE AND DRAIN AT ICE MACHINE AS REQUIRED. 8 EXISTING CASEWORK TO REMAIN. PROTECT DURING ALL PHASES OF COORDINATE WITH TENANT. CONSTRUCTION. 8 SERVICE COUNTER POS SECTION AT 34" AFF. REFER TO INTERIOR SERVICE ELEVATIONS. 6 101 0403 9 EXISTING STAFF RESTROOM AND FIXTURES TO REMAIN. 10'-0" A400A400 COORDINATE WITH TENANT. 11 7 2 10 EXISTING DOOR TO REMAIN. 1 4'-2" 11 4'-0"1 2 FLOOR DRAIN, FIELD VERIFY LOCATION AND PROVIDE NEW AS REQUIRED FOR NEW EQUIPMENT. COORDINATE WITH TENANT. 12 PROVIDE MOP SINK WITH WATER HEATER INSTALLED ON SHELF ABOVE. 1313 W2 13 BULKHEAD ABOVE. REFER TO REFLECTED CEILING PLAN FOR MORE INFORMATION. 14 EXISTING STOREFRONT TO REMAIN. 06 16 " F.V. A400 1 2 PREP 15 EXISTING COUNTERTOP TO REMAIN. FIELD VERIFY LOCATION AND 9'-0 COORDINATE WITH TENANT. 102 05 10'-0" A400 30" D S.S. COUNTERTOP AND BASE CABINET WITH 4" S.S. 16 3 BACKSPLASH. 17 EXISTING BANQUETTE TO REMAIN. COORDINATE WITH TENANT AS REQUIRED. 2 E X WALL-MOUNTED FIRE EXTINGUISHER LOCATION. PROVIDE 18 I S 1'-6" T I N G EXTINGUISHER, BRACKET AND REQUIRED SIGNAGE. EXACT CLEAR LOCATION & NUMBER TO BE VERIFIED BY FIRE MARSHALL AND TENANT. 10 3 19 COORDINATE AND PROVIDE POWER FOR TENANT FURNISHED EXTERIOR SIGN ABOVE STOREFRONT. 18 5 4 07 2'-6" 20 FURNITURE BY TENANT. A400 W1 FE 21 EXISTING ELECTRICAL PANEL LOCATION TO REMAIN. PREP 103 22 PROVIDE AND INSTALL NEW 18" ADA COMPLIANT VERTICAL GRAB BAR IN STAFF RESTROOM. 2'-5" 10'-0" 12 10 WALL TYPE LEGEND 3 PREP 1 11 RESTROOM 104 2 3-5/8" X 25 GA. METAL STUDS AT 16" O.C. W1 105 G N I 9 T WITH 5/8" TYPE "X" GYPSUM WALLBOARD S I 10'-0" 6 X E 9'-0" EACH SIDE. 21 1'-0" 22 7 CLEAR 3-5/8" X 22 GA. METAL STUDS AT 16" O.C. W2 WITH 5/8" TYPE "X" GYPSUM WALLBOARD EACH SIDE AND SOUND ATTENUATION 2 E X BLANKETS IN EACH STUD CAVITY. I S T I N G EX EXISTING WALL CONSTRUCTION TO REMAIN. MAINTAIN WALL RATING WHERE 10 APPLICABLE. * ALL WALL TYPES SHALL BE EXISTING UNLESS NOTED OTHERWISE. * FOR WALL HEIGHTS, REFERENCE REFLECTED CEILING PLANS. * PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT ALL "WET" LOCATIONS. GENERAL FINISH PLAN NOTESGENERAL CEILING NOTES REFER TO REFLECTED CEILING PLAN FOR NOTES REGARDINGALL WALLS EXTEND TO 6" ABOVE CEILING UNLESS NOTED AS FOLLOWS: A.A. ACOUSTICAL CEILING GRID AND TILES. NOTE: REFER TO EQUIPMENT PLAN 1/A300 48" WALLS TO 4'-0" ABOVE CEILING HEIGHT BOTTOM SIDE OF ALL HARD CEILINGS TO BE PAINTED WHITE UNLESS B. J OTHERWISE NOTED. WALLS TO JOISTS ABOVE D HOLLOW METAL INTERIOR DOOR FRAMES TO BE PAINTED C. WALLS TO DECK ABOVE TO MATCH ADJACENT WALL. LIGHT FIXTURE AND DIFFUSERS ON DRAWINGS SHOWN FOR LOCATION B. ALL FLOORING TRANSITIONS SHALL OCCUR BENEATH THE CLOSED D. ONLY. COORDINATE WITH MECHANICAL AND ELECTRICAL DOOR. PROVIDE TRANSITION STRIPS PER MANUFACTURER'S DRAWINGS FOR EXACT SPECIFICATIONS AND VERIFICATION STANDARDS IN COLOR SELECTED BY ARCHITECT. OF QUANTITY. E. PROVIDE SHOP DRAWINGS ON ALL FINISHES PRIOR TO ORDERING ALL CEILINGS ARE TO BE INSTALLED AT +10'-0" A.F.F. OR ABOVE C. MATERIALS AND COORDINATE WITH ARCHITECT AND TENANT. EXTERIOR WINDOW HEAD, WHICHEVER IS GREATER, UNLESS NOTED OTHERWISE. D.CENTER ACOUSTICAL CEILING PANELS IN EACH DIRECTION WITHIN THE MAIN PORTION OF ANY ROOM OR SPACE, UNLESS NOTED OTHERWISE. D.EXISTING CEILING PANELS, CEILING GRID, LIGHT FIXTURES, AND DIFFUSERS TO REMAIN. PROTECT DURING ALL PHASES OF FINISH PLAN NOTES CONSTRUCTION. MODIFY AS REQUIRED TO ACCOMMODATE NEW FLOOR PLAN. ALL WALLS SHALL BE PREPARED AS REQUIRED TO RECIEVE WALL 1 FINISH AS SPECIFIED, VERIFY FINAL PAINT LOCATIONS WITH TENANT CEILING PLAN NOTES PRIOR TO COMMENCEMENT OF WORK. EXISTING CEILING PANELS, CEILING GRID, LIGHT FIXTURES, AND 1 2 COORDINATE TENANT SUPPLIED GRAPHICS TO BE INSTALLED. DIFFUSERS TO REMAIN. PROTECT DURING ALL PHASES OF P1 F2 PROVIDE BLOCKING AS REQUIRED FOR EQUIPMENT AND GRAPHICS. CONSTRUCTION. 3 PROVIDE STAINLESS STEEL BASE SSB1 THROUGHOUT UNLESS 2 EXISTING HVAC DUCTWORK ABOVE TO REMAIN. PROTECT DURING NOTED OTHERWISE. F1F1F1 ALL PHASES OF CONSTRUCTION. 4 PROVIDE FRP1 AT ALL WALLS LOCATED IN PREP AREA. FRP TO 3 EXISTING GYPSUM BOARD BULKHEAD TO RECIEVE WASHABLE SATIN EXTEND FROM FLOOR TO CEILING. FINISH PAINT. PREPARE CEILING SURFACE AS REQUIRED TO ACCEPT NEW FINISH. REFER TO 2/A200 FOR MORE INFORMATION. 5 NOT USED. PROVIDE LIGHTING IN STEEL CHANNELS AT SNEEZE GUARD. 4 6 GYPSUM BOARD CEILINGS SHALL BE PREPARED AS REQUIRED TO LIGHTING SHALL PROVIDE 120 LUMENS CONTINUOUS TASK LIGHT F2 RECIEVE PAINT FINISH P3. SATIN PAINT FINISH. LEVEL AT THE COUNTER SURFACE. REFER TO 8/A400 FOR MORE INFORMATION. 7 SERVICE COUNTER TO BE GRANITE COUNTERTOP WITH S.S. OPEN 2 1 F1F1F1 SHELVING/LEGS AND GRANITE TILE WITH METAL ACCENT STRIPS AT LINE OF GYPSUM BOARD BULKHEAD AT 8'-0" AFF AS REQUIRED. 5 FRONT FACE AS INDICATED. REFER TO INTERIOR ELEVATIONS FOR MORE INFORMATION. 11 SEATINGSEATING 1 8 BACK COUNTER/BASE CABINET SHALL BE STAINLESS STEEL DOOR 6EXISTING LIGHT FIXTURES TO BE RELOCATED TO ACCOMMODATE R 100100 PANELS ON S.S. FRAME WITH S.S. COUNTERTOP AND BACKSPLASH. 3 12 NEW STORE LAYOUT. E 123 M 9 I 10"-0" R 9 PROVIDE PRIMER PAINT FINISH AT WALL TO RECIEVE GRAPHICS, 2 PROVIDE AND INSTALL NEW 9 HEAD TRACK LIGHT FIXTURE 7 P COORDINATE WITH TENANT. CENTERED ABOVE CASE BELOW. COORDINATE FINAL LOCATION WITH 6 SC1 F2F2 TENANT PRIOR TO INSTALLATION. -- 10 PROVIDE ACCENT WALL PAINT P1 AS INDICATED. 8 EXISTING RESTROOM EXHAUST FAN TO REMAIN. PROTECT DURING P33 F1 11 PROVIDE 36" H. WAINSCOT TREATMENT -WP1, S.S. CHAIR RAIL, ALL PHASES OF CONSTRUCTION. WOOD PANEL AND STAINLESS STEEL BASE. REFER TO 3/A300 FOR MORE INFORMATION. 9'-4" 12 IMPACT WALL, WALL PLANK PANELS WITH TENANT SUPPLIED GRAPHICS, COORDINATE AS REQUIRED. CEILING LEGEND 12 F2F2F2 F2 EXTEND WALL TO DECK GYPSUM BOARD 9'-0" FINISH REMARKS 2x4 SUSPENDED ACOUSTICAL PANEL CEILING (SEE FINISH SCHEDULE FOR TYPE) SC1 FLOOR FINISH MATERIAL OR PATTERN VARIES. 1. CEILING FINISH VARIES. REFER TO REFLECTED CEILING PLANS. 2. EXISTING 2 x 4 FLUORESCENT WALL FINISH MATERIAL VARIES. 3. 2 BULB PARABOLIC LENS 7 7 PC1 PROVIDE 6"H WALL BASE IN TOILET ROOMS AND WET AREAS. 4. EXISTING 12 x 12" RETURN AIR GRILLE F3 EPOXY PAINT TO BE USED IN TOILET ROOMS AND WET AREAS. 5. F4 PROVIDE STAINLESS STEEL WALL BASE SSB1. 6. EXISTING 12 x 12" HVAC DIFFUSER PROVIDE TILE BASE TB1 IN ALL TILE LOCATIONS. 7. SERVICESERVICE EXISTING 1/2" X 1/2" PLASTIC EGGCRATE AIR RETURN 101101 ACT - ACOUSTICAL CEILING TILE PC16 47 24X48 FOR T-BAR LAY-IN CEILING TO BE REUSED FINISH LEGEND PC - POLISHED CONCRETE F3F3 -- 10'-0" 36 8 EXISTING 2 x 2 HVAC DIFFUSER TO BE SC - STAINED CONCRETE ROOM RELOCATED TO ACCOMMODATE NEW LAYOUT P33 QT - QUARRY TILE ENTRYNAME TB - TILE BASE 101 ROOM 2 1 EXISTING RECESSED CAN LIGHT FIXTURE 10 TS - TRANSITION STRIP FLOOR FINISH-- NUMBER SSB - SOLID SURFACE BASE CEILING FINISH -- 55 EXISTING EXIT LIGHT FIXTURE. SINGLE FACE GREEN P1 P - PAINT WALL FINISH --REMARKS LETTERS FRP - FIBER REINFORCED PANEL COLUMN EXISTING EMERGENCY WALL PACK WITH BATTERY BACKUP FINISH MATERIALS SCHEDULE D HALOGEN TRACK LIGHTING FIXTURE DESIGNATIONMANUFACTURERCOLOR NUMBERCOLOR NAME FLOOR FIXTURE RESPONSIBLITY LEGEND PC.1 --- 2 1 C.F.C.I.T.F.C.I.V.F.C.I. 666 SC.1 --- 8 3 PC16 PREPPREP DAL-TILE QT.1 TBDTBD 12"X12" QUARRY TILE ACT- 102102 4 TS.1 JOHNSONITECE 20 CBLACK FRP- F3F3F3 LIGHT FIXTURE SCHEDULE 10'-0" DESIGNATIONDESCRIPTIONMODEL NUMBER RESP. WALLS PC1 F1EXISTING-- SSB.1 BY VENDOR DAL-TILE -- F2EXISTING TB.1 TO MATCH QT.1 QUARRY TILE BASE QT1 -- F3EXISTING P1SHERWIN WILLIAMS SW6871POSITIVE RED C.F.C.I F49 HEAD TRACK LIGHT FIXTURE-TBD P2NOT USED P3SHERWIN WILLIAMS SW7557SUMMER WHITE P4 2 SHERWIN WILLIAMSSW6506VAST SKY 1 MARLITE FRP1 P100WHITE STYLE-PEEBLE WAINSOT : 2" FLAT S.S. CHAIR RAIL AT 36" AFF WITH CLEAR WP1 SEALED 36" MAPLE WOOD PANELS BELOW AND SSB.1 BASE. CHAIR RAIL AND BASE SUPPLIED BY SUBZERO VENDOR F3F3F3 48" QT17 PREP MILLWORK PREP - ACT1 4 103103 PLASTIC LAMINATE : WILSONART, BLACK 1595 MATTE FINISH PLAM1 FRP- OR APPROVED EQUAL AT WORK COUNTER 10'-0" MS INTERNATIONAL, METRO GRIS INTERLOCKING 12X12 GLASS TILE STONE MESH MOUNTED MOSAIC TILE AT FACE OF SERVICE COUNTER, THIN SET INSTALLATION. 1 PREPPREP RESTROOMRESTROOM 104104 105105 2 10'-0" F3 9'-0" F3 8 - EXIST - EXIST - P4 NOTE: COORDINATE ALL GRAPHIC ARTWORK AND FURNITURE AND EQUIPMENT SCHEDULE SIGNAGE WITH SUBZERO CORPORATE. NOTE: G.C. IS TO COORDINATE, VERIFY, MATCH, E1TABLE TOP WITH BASE 6VARIES COORDINATE WITH TENANT SEATING AREA - EXISTING? AND PROVIDE THE CORRECT STYLE/COLOR/TYPE 22 OF THE APPROVED CORPORATE SUB ZERO ICE E2 TABLE CHAIR SEATING AREA COORDINATE WITH TENANT - EXISTING? CREAM AND YOGURT SERVICE COUNTER AND SNEEZE QUARD, AS APPROVED BY SUBZERO COORDINATE WITH TENANT SEATING AREA E3 - SINGLE PLAIN BACK BOOTH 1 EXISTING? TEXAS, AND SUBZERO CORPORATE, UTAH E4 LOCKERS PREP AREA 0 -- COORDINATE WITH TENANT 0 E5COORDINATE WITH TENANT SEATING AREA E LOUNGE CHAIR MODERN LINE FURNITURE9049-B-CH X I S T I N G 0 E6COORDINATE WITH TENANT SEATING AREA SOFA MODERN LINE FURNITURE 9049B-S COORDINATE WITH TENANT E7 SEATING AREA 0 COFFEE TABLES CT72ROUND-BLK MODERN LINE FURNITURE COORDINATE WITH TENANT E8SERVICE/PREP S.S. TANK 1-- SERVICE MAIN COUNTER/BASE E91-- SERVICE AREA POS SERVICE COUNTER/BASE E101-- SERVICE AREA BACK COUNTER/BASE CABINETSERVICE AREA E112 24-30" DEEP VARIES - 1 WALL MOUNT HAND SINK E12EXSTING SERVICE/PREP AREA -COORDINATE WITH TENANT AS REQUIRED PREP AREA E13 30" X 72" S.S. WORK TABLE COORDINATE WITH TENANT AS REQUIRED 0-- 15" D X 36" W S.S. SHELFPREP AREA E144 ADVANCE TABCO WS15-48 SHELF OVER WORK TABLE & 3 COMP SINK. PROVIDE BLOCKING IN WALL 2 CMEP1848-NDG 18" D X 48" W SHELVINGPREP AREAEPOXY COATED, PROVIDE WALL BRACKET AS REQ'D. E15THUNDER GROUP REACH IN REFRIGERATORPREP AREAOR APPROVED EQUAL E161 T-49-HC 54" TRUE FOOD SERVICE EQUIP. REACH IN FREEZERTS-49F-HC 54"PREP AREAOR APPROVED EQUAL E171 TRUE FOOD SERVICE EQUIP. EXISTINGPREP E18 7' LONG, COORDINATE WITH TENANT S.S. 3-COMPART. SINK 1- SEATING 100 PREP E19 VERIFY WATER HEATER 1RELOCATED EXIST.- PREP E20 24X24 MOP SINK1RELOCATED EXIST. E21 SERVICE AREA 1-- POINT OF SALE UNIT SERVICE AREA E22 3-- 10" DIAM SCO0PER BOWL REFER TO DETAIL 8/ID4 SERVICE AREA E23 - SNEEZE GUARD2- SERVICE AREA E24 21"X63" WITH (3) DIPPER WELLS AND LN2 LINES 1SMS- FREEZE RELEASE PAN 9'-4" SERVICE AREA E25 1-21X29 NON REF. DRY MIX DROP IN SERVICE AREA E26 REF. WET MIX DROP IN 1-21X29 9'-0" SERVICE AREA E27 ON TOP OF SODA DISPENSER -24X24 ICE MAKER1 0 E28 SERVICE AREA - DROP N SS SINGLE SINK - UNDERCOUNTER REFSERVICE AREA E291-28X24 -SERVICE AREA PROVIDE MOUNTING DREAM MD2377 TV WALL BRACKETS E30 ELECTRIC MENU MONITORS5 MOUNTED VERTICALLY - SERVICE AREA E31 1SPACEWELL 10" ICE CREAM DIPPER STATION - SERVICE AREA E32 SERVICE 2- 42" SS SPEED RAIL 101 PREP AREA E33 TUC-72 3 DOOR UC REFRIGERATORS2 TRUE FOOD SERVICE EQUIP. -COORDINATE LOCATION WITH TENANT SEATING AREA E34 0 - FLAT SCREEN TV - S.S. SHELVING 24" D X 60 WPREP AREA E35 3 COORDINATE WITH TENANT - - PREP AREA E36 4 S.S. SHELVING 24 D X 36" / 48" W SIZE AS INDICATED COORDINATE WITH TENANT - E37SODA DISPENSERAS SELECTED BY TENANT - SUBMIT FOR APPROVAL 1SERVICE AREA - - E38TRASH CANAS SELECTED BY TENANT 1 SEATING AREA - - AS SELECTED BY TENANT E39STAFF LOCKER 1 PREP 104 - - E4018"L X 1-1/4" DIA GRAB BAR ADA COMPLIANT VERTICAL GRAB BAR WITH REQUIRED WALL ANCHORS 1 RESTROOM 105 - PREP 102 PROVIDE NOTCH OUT AT BASE CABINET AS E REQUIRED DUE TO X I S T I N TANK VALVE/LINE G 3'-0"15'-4 1/2" WALL PAINT FINISH AS SCHEDULED FE PREP 103 2" S.S. STRAIGHT CHAIRAIL PREP RESTROOM 3'-0" 104 105 G N I T S I X E E X I S T I N G CLEAR SEAL MAPLE WOOD PANEL LN2 LINE TAP, VERIFY 3'-0" QUANTITY WITH 3'-8 1/2" TENANT AND EXACT LOCATION WITH EQUIPMENT 2'-0" 4" S.S. STRAIGHT BASE GENRAL NOTE: SNEEZE GUARD LIGHT REQUIREMENT: THE LIGHT STRIP IN THE STEEL CHANNEL IS TO PROVIDE 120 LUMEN TASK LIGHT LEVEL AT THE COUNTER SURFACE. 9" FIELD VERIFY 1" DIAM. STAINLESS STEEL GLASS CONNECTOR SNEEZE GUARD REFER: DTL 10/A4 3'-0" 1 " TEMPERED GLASS 2 GRANITE COUNTERTOP 1 " TEMPERED GLASS ST. STEEL CHANNEL WITH 4 MINI-FLOURESCENT LIGHT "C" CHANNEL WELL INSERT AS SCHEDULED 1-1/2" STAINLESS STEEL SQUARE TUBE 1 " PLYWOOD SHEATHING 2 1 1-1/4" X " STAINLESS STEEL FLAT BAR CURVED AS 4 "C" CHANNEL REQUIRED TO ACCOMMODATE GLASS TOP AND WITH METAL PANEL 1'-5"-1/2" TABS TO ACCOMMODATE GLASS FACE WITH S.S. GLASS CONNECTORS FIELD VERIFY "BLACK" TILE - THIN SET INSTALL. 1-1/2" DIAM. S.S. POST PROVIDE COLORED ROPE LIGHT IN FRONT STEEL METAL PANEL CHANNEL GRANITE COUNTERTOP 3'-0" A.F.F. OPEN S.S. SHELF 1 2" X " STAINLESS STEEL FLAT 2 GENRAL NOTE: G.C. TO FIELD VERIFY EXISTING SERVING BAR COUNTER AT SUBZERO NEAREST LOCATION FOR COMPANY STANDARD REQUIREMENTS, FIELD VERIFY AND MATCH EXISTING STYLE/COLOR/TYPE 2" BREAK METAL KICK 2-1/2" BASE AS SCHEDULED FIELD VERIFY 1'-2" FIELD VERIFY CLG. AS SCHED. CLG. AS SCHED. CLG. AS SCHED. CLG. AS SCHED. E14E14 E30E30E30E30E30 E27 E14E14E35 E15 E35E35 E15 E37 10'-0"10'-0" E11 OPENINGOPENING E11 E12 OPENINGOPENING E18 EXISTING EXISTING DOOR DOOR E29 E16 E17 E33E33 6'-2-1/4" 4'-0" SSB1SSB1 TB1 PRIMER PRIMER 08 A400 E8 0303 E30E30E30E30E30 E9 E19 A300A300 E10 REST.SEATING E23E23 E23 E23 E9 PREPPREP SERVICE 10'-0" 1OO 105 E10 103 101 102 E21 E1E1E1 E25E31 E24 E31E32 E26 E20 3'-0" 2'-10" E2 E8E2E2 E2 E2 TB1 SSB1 SSB1 POWER AND TELEPHONE PLAN NOTES: 1CONTRACTOR TO CONFIRM ALL OUTLET LOCATIONS WITH TENANT PRIOR TO INSTALLATION. VERIFY EXISTING TO ENSURE ADEQUATE SUPPLY. 23/4" THICK 4X4 PLYWOOD PANEL INSTALLED 4'-0" A.F.F. FOR TELEPHONE EQUIPMENT, VIF. COORD. WITH TENANT FOR EXACT REQUIREMENTS. 3PROVIDE POWER AS REQUIRED FOR ALL TENANT PROVIDED EQUIPMENT AT SERVICE 101 AND PREP 102-104, COORDINATE WITH TENANT 4PROVIDE POWER FOR "OPEN" SIGN AND ANY OTHER TENANT PROVIDED SIGNAGE AS REQUIRED, COORDINATE AND CONFIRM WITH TENANT. 5PROVIDE DATA JACK, CONDUIT ABOVE CEILING AND PULL STRING AS REQUIRED TO ELECTRIC MENU BOARDS, COORDINATE WITH TENANT FOR MENU MONITOR SIZE AND EXACT LOCATION, PROVIDE ELECTRICAL AT HT. AS REQUIRED. 6PROVIDE (2) QUAD OUTLETS AT POS, COORDINATE WITH TENANT AS REQUIRED 7PROVIDE ELECTRICAL OUTLET AS REQUIRED FOR AIR QUALITY MONITOR AT TANK AREA, COORDINATE WITH TENANT 8PROVIDE ELECTRICAL OUTLET FOR LN2 LEVEL MONITOR AT TANK AREA. COORDINATE WITH TENANT. 9VERIFY NUMBER OF BOWLS AND LN2 TAPS WITH TENANT, PROVIDE OUTLETS AS REQUIRED FOR EACH BOWL AND FOOT PEDALS AT BOWLS AND LN2 TAPS. COORDINATE WITH TENANT AS REQUIRED. 10PROVIDE ELECTRICAL OUTLET AT REFRIGERATED DROP IN WELL. COORDINATE WITH TENANT AS REQUIRED. 11PROVIDE AND INSTALL 3" DIAM. GROMMET AT POS COUNTERTOP - COORDINATE ACTUAL LOCATION WITH SEATING TENANT EQUIPMENT. 100 12COORDINATE W/ TENANT FOR ANY ELECTRICAL REQUIREMENTS FOR TENANT PROVIDED TV MONITORS AT 84", I.E., CABLE, EXACT HEIGHT AND LOCATION OF OUTLETS. 13PROVIDE JBOX AT SNEEZE GUARD FOR LIGHTING, REFER TO SHEET A3, COORDINATE WITH TENANT AS REQUIRED 14PROVIDE ELECTRICAL AS REQUIRED TO ACCOMMODATE ICE MACHINE, SODA DISPENSER AND U.C. REF, COORDINATE WITH TENANT. 9'-4" 15VERIFY LOCATION OF ELECTRICAL PANELS TO REMAIN POWER & TELEPHONE PLAN LEGEND 9'-0" SERVICE 101 PREP 102 FE PREP 103 PREP RESTROOM 104 105