Loading...
HomeMy WebLinkAbout03040103.5O r - PER 12 MANUFACTURED TRU55E5 @ 2'-0" O.G. ELEVF— OR RAFTERS PER PLAN FIBER6LA55 SHINGLE I5# FELT 7/16" WAFER BOARD R-38 BLOWN INSULATION I"x6" FASCIA BOA 1/2" DRYWALL 2"xb" GUTTER BOAR 2x4 DBL. TOP PLATE 3/8" R/5 PLYWOOD 2x4 STUD ® 16" O.G. SOFFIT BOARD R-13 FIBERGLASS INSULATION 2"x4" BLOGK 1/2" DRYWALL 1/2" RIGID INSULATION SIDING PER SPEC. BAND BOARD 2"x6" GGA SILL PLATE TUFF -N -DRY R1610 INSULATION 4" PERFERATED DRAIN PIPE VAPOR BARRIER COMPOSITE R -VALUE = Iq (TYP.) 2"x4" 50LE PLATE —3/4" PLYWOOD, SLUED a NAILED q 1/2" I -JOIST #2 5.Y.P. KD 24" O.G. SUPPLY ANCHOR STRAP ® 32" O.G. 8" THICK POURED GONG. FOUNDATION WALL (HEIGHT PER SPECS) W/ STEEL VERTICAL REINFORCEMENT; N. (SIZE d SPACING PER IRG TABLE R404.1.1(2) 4" GONG. SLAB GRANULAR FILL Q22MED "x16" CONT. POURED FOOTING WALL DETAIL W/E3ASEMENT • COMPOSITE R VALUE FOR TYPIGAL WALL GONSTRUGTION Inside Air Film .68 1/2" Drywall .45 Insulation 15.0 R -Board 5.5 Siding .-7 Airspace Btwn R -Board and Sidnig 5 Outside Air Film .I-7 TOTAL Iq.O (2) 2x8 HE, Lu kti NW q) [L UJ Z FIRE j 7 MA HE, 8" CLEARANCE METAL FLUE 8" CLEARANCE METAL FIREPLACE ;OMB. AIR FROM OUTSIDE • FIBERGLASS SHINGLE 15# FELT -7/16" WAFER BOARD MANUFACTURED TRUSSES @ 2'-0" O.G. PER 12OF,RAFTERS PER PLAN ELEVF- 1"xb" FASCIA BOARD R-38 B OWN INSULATION 2 x6 GUTTER BOARD 1/JD YWA 3/8" R/S PLYWOOD 2xL. OP PLATE 2x4 STUD ® 16" O.G. SOFFIT BOARD R-13 FIBERGLASS INSULATION Ix4 FRIEZE BOARD 2x4 BLOC 1/2" DRYWALL VAPOR BARRIER 1/2" RI61D INSULATION SEMI -PERMEABLE AIR INFILTRATION BARRIER BEHIND BRICK NOTE: WEEPHOLES SHALL BE PROVIDED IMMEDIATELY ABOVE FLASHING UNDER STONE OR BRICK WINDOW SILLS; MAX. 32" O.G.; AIR SPACE MIN. 3116" DIA. BRICK VENEER 2x4 GGA SILL PLATE z \ CD SOLE PLATE K 07 ILI2"x4" 3/4" PLYWOOD, GLUED d NAILED FLASHING C) Q 6 WEEPHOLE; MAX. 33" O.G.; q 1/2" I-JO15T #2 S.Y.P. KD 24" O.G. MIN. 3116" DIA. (1) COURSE OF 8x16 "L" BLOCK BAND BOARD GRADE SUPPLY ANCHOR STRAP (p 32" O.G. RII BATT INSULATION (3) COURSES OF 8"x16" GONG. BLOCK OR POURED CONCRETE 8"x16" POURED GONG. FOOTING GRANULAR FILL d3 Cv HALL SECTION ON GRAWL FIBERGLASS SHINGLE 15# FELT i/16" WAFER BOARD • 1"x6" FASCIA BOARD 2"xb" GUTTER BOARD - 3/8" R/S PLYWOOD _ SOFFIT BOARD 1"x4" FRIEZE BOARD - 2x4 BLOCK - SEMI -PERMEABLE AIR INFILTRATION BARRIER BEHIND BRICK 12 MANUFACTURED TRUSSES o 2'-0" O.G. PER F— OR RAFTERS PER PLAN ELE -38 LOWN INSULATION .I/2" DR WA L 2x4 DBL. OP PLATE 2x4 STUD ® I6" O.G. R-13 FIBERGLA55 INSULATION 1/2" DRYWALL VAPOR BARRIER NOTE: WEEPHOLES SHALL BE PROVIDED AIR SPACE IMMEDIATELY ABOVE FLASHING UNDER STONE OR BRICK WINDOW SILLS; MAX. 32" O.G.; MIN. 3/16" DIA. 1/2" R161D INSULATION BRICK VENEER GGA BOTTOM PLATE FLA5HIN6 WEEPHOLE; MAX. 33" O.G.; MIN. 3/16" DIA. SUPPLY ANCHOR STRAP ® 32" O.G. WOOD BASEBOARD 4" GONG. SLAB (b MIL. VAPOR BARRIER -R1610 INSULATION 2"x 48" CONT. -GRANULAR FILL 8" GONG. BLOCK OR POURED CONCRETE 12"x24" POURED GONG. FOOTING / z \ CD Qz� K 07 Q/ ks) C) Q 6