HomeMy WebLinkAboutAddendum 2RATIO ARCHITECTS, INC. ADDENDUM NO. 2 – PAGE 1 BUSEY BANK TENANT IMPROVEMENT INDY 04/11/2017 BUSEY BANK TENANT IMPROVEMENT INDY 16071.000 ADDENDUM NO. 1 DATE: April 11, 2017 PROJECT: BUSEY BANK TENANT IMPROVEMENT INDY RATIO PROJECT NUMBER: 16071.000 OWNER: First Busey Corporation ARCHITECT: RATIO ARCHITECTS, INC. 301 N. Neil Street Suite 102 Champaign, IL 61820 217-352-7696 KBSO Consulting 1344 S. Rangeline Road Suite 202 Carmel, IN 46031 317-344-8046 This Addendum is issued in accordance with the provisions of The General Conditions of the Contract for Construction, Article 1 Contract Documents, and becomes a part of the Contract Documents as provided therein. The information contained herein modifies the original Bidding Documents dated 03.13.2017. Requirements of the original Bidding Documents and previous Addenda remain in effect except as modified by this Addendum. Acknowledge receipt of this Addendum in the space provided on the Bid Form. Failure to do so may subject the Bidder to disqualification. PART 1 – PROJECT MANUAL CHANGES 1. n/a PART 2 – DRAWING CHANGES 1. SHEET E-601 – ELECTRICAL SCHEDULES a. Light fixture schedule has been revised. Replace existing sheet with new attached sheet. PART 3 – CLARIFICATIONS 1. n/a PART 4 – ATTACHMENTS 1. Drawing E-601 – ELECTRICAL SCHEDULES. END OF ADDENDUM NO. 2 CHECKED BY APPROVED BY COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO ARCHITECTS, INC. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO ARCHITECTS, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. SHEET TITLE SHEET NUMBER First Busey Corporation 201 W. Main St. Urbana, Illinois 61801 (217) 365-4500 Owner RATIO Architects, Inc. Architect 301 North Neil Street, Suite 102 Champaign, Illinois 61820 (217) 352-7696 Mech / Elec / Plumbing / FP Engineer KBSO Consulting, Inc. 1344 S. Rangeline Rd. Indianapolis, Indiana 46032 (317) 973 0874 PROJECT NO. REISSUE ISSUE FOR REVIEW / BID 03.13.2017 4/11/2017 11:00:17 AME-601 ELECTRICAL SCHEDULES 16071.001 SJB JAS Busey Bank Tenant Improvement Indy 11550 N. Meridian Street Carmel, IN 46032 LIGHT SOURCE DRIVER/BALLAST INSTALLATION LIGHTING FIXTURE SCHEDULE FIXTURE TYPE DESCRIPTION LUMENS COLOR LAMP TYPE EFFICACY WATTS BALLAST VOLTS MOUNTING MANUFACTURER EQUAL MANUFACTURER Count L1 2'x4' PARABOLIC (EXISTING TO BE RE-USED) 8256 lm 3500 K T8 86 lm/W 96 W N/A 120V GRID N/A 60 L2 4" RECESSED CAN LIGHT 1189 lm 3500 K LED 93 lm/W 13 W ELECTRONIC (0-10V DIM.) 120V RECESSED GOTHAM (EVO R 4) PORTFOLIO (LD4B), VANTAGE (A4VOCLED) 33 L3 6" PENDANT CAN LIGHT 1573 lm 3500 K LED 85 lm/W 19 W ELECTRONIC (0-10V DIM.) 120V SUSPENDED GOTHAM (EVO CYL 6) PORTFOLIO (LSR6B 15), VANTAGE (VP614LED) 4 L4 COVE STRIP LIGHT 1156 lm 3500 K LED 76 lm/W 15 W ELECTRONIC (0-10V DIM.) 120V WALL LUMINII (KENDO S) ACCLAIM (ACE) 25 L5 LINEAR WALL WASH 1219 lm 3500 K LED 53 lm/W 23 W ELECTRONIC (0-10V DIM.) 120V WALL FOCAL POINT (FOCUS) ALW (HYMGR), MARK (SPR LED) 4 L6 LED STRIP LIGHT 2151 lm 3500 K LED 115 lm/W 19 W ELECTRONIC (0-10V DIM.) 120V SURFACE LITHONIA (WL4) METALUX SW LED, CREE (LS) 1 X1 DIECAST LED EXIT SIGN (GREEN)LED 120V CEILING LITHONIA (LE) SURE-LITES (CX), MULE (MD B U) 4 X2 DIECAST LED EXIT SIGN (GREEN)LED 120V WALL LITHONIA (LE) SURE-LITES (CX), MULE (MD B U) 3 CONTRACTOR TO FIELD VERIFY ALL EXISTING CIRCUITS TO REMAIN AND BALANCE PANEL ACCORDINGLY. PROVIDE NEW PRINTED PANEL SCHEDULE FOR PANEL DOOR UPON COMPLETION OF WORK. Notes: R 0 VA 0.00% 0 VA Total Est. Demand:80 A Other 26940 VA 100.00% 26940 VA Total Conn.:80 A Heating 54 VA 100.00% 54 VA Total Est. Demand:28644 VA HVAC 0 VA 0.00% 0 VA Total Conn. Load:28644 VA Appliance - Dwelling Unit 1650 VA 100.00% 1650 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps:92 A 66 A 85 A Total Load:10768 VA 7978 VA 9898 VA 41 42 39 40 37 38 35 ---- --18 VA 36 33 ---- -- 18 VA 34 31 COIL HEATER EDC-1 20 A 3 18 VA 32 29 114 RADIANT PANEL 20 A 1 380 VA 380 VA 1 20 A 115 RADIANT PANEL 30 27 RESTROOM EXHAUST FAN 20 A 1 0 VA 380 VA 1 20 A 117 RADIANT PANEL 28 25 GARBAGE DISPOSAL 20 A 1 1000... 1650...1 30 A WATER HEATER 26 23 OFFICE 105 & WRR RECEPTACLES 20 A 1 1660... 1440... 1 20 A SUPPLIES & MRR RECEPTACLES 24 21 IT EQUIPMENT 20 A 1 180 VA 1260... 1 20 A IT ROOM RECEPTACLES 22 19 LOBBY RECEPTACLES 20 A 1 720 VA 1440...1 20 A WORK ROOM RECEPTACLES 20 17 LOUNGE REFRIGERATOR 20 A 1 180 VA 1080... 1 20 A LOUNGE RECEPTACLES 18 15 LOUNGE MICROWAVE 20 A 1 1000... 1000... 1 20 A LOUNGE DISHWASHER 16 13 TELLER RECEPTACLES 20 A 1 1880... 1000...1 20 A LOUGE MICROWAVE 14 11 OFFICE 117 RECEPTACLES 20 A 1 720 VA 1520... 1 20 A OFFICE 103&104 RECEPTACLES 12 9 STOR. 113 COPIER 20 A 1 180 VA 1260... 1 20 A OFFICE 118&121 RECEPTACLES 10 7 VESTIBUILE 100 & OFFICE 120 RECEPTACLES 20 A 1 720 VA 180 VA 1 20 A STORAGE 101A COPIER 8 5 CUBICLE 101F&WALL RECEPTACLES 20 A 1 1440... 1080... 1 20 A CUBICLE 101H&101G RECEPTACLES 6 3 OFFICE 123&124 RECEPTACLES 20 A 1 1440... 1260... 1 20 A OFFICE 119&122 RECEPTACLES 4 1 OFFICE 114 & 115 RECEPTACLES 20 A 1 1080... 1080...1 20 A CONFERENCE ROOM RECEPTACLES 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: Enclosure:Type 1 MCB Rating: Mounting:Recessed Wires:4 Mains Rating:100 A Supply From:Phases:3 Mains Type: Location:EXISTING BLDG. PHONE 191 Volts:120/208 Wye A.I.C. Rating: Branch Panel: LP1 CONTRACTOR TO FIELD VERIFY ALL EXISTING CIRCUITS TO REMAIN AND BALANCE PANEL ACCORDINGLY. PROVIDE NEW PRINTED PANEL SCHEDULE FOR PANEL DOOR UPON COMPLETION OF WORK. Notes: Total Est. Demand:22 A Total Conn.:18 A L 0 VA 0.00% 0 VA Total Est. Demand:7998 VA Other 0 VA 100.00% 0 VA Total Conn. Load:6398 VA Lighting 6398 VA 125.00% 7998 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps:15 A 22 A 16 A Total Load:1834 VA 2607 VA 1957 VA 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 LOBBY, CORRIDOR, RECEPTION LIGHITNG 20 A 1 394 VA 8 5 101B, 102, 105, 108-111 LIGHTS 20 A 1 1416... 541 VA 1 20 A CORRIDOR LIGHITING 6 3 ROOMS 101D, 114-118, AND 121 LIGHTS 20 A 1 1440... 1167... 1 20 A ROOMS 103, 104, 106, 107 LIGHTS 4 1 EMERGENCY LIGHTING 20 A 1 288 VA 1152...1 20 A 101A, 119-124 LIGHTING 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: Enclosure:Type 1 MCB Rating: Mounting:Recessed Wires:4 Mains Rating:100 A Supply From:Phases:3 Mains Type: Location:EXISTING BLDG. PHONE 191 Volts:120/208 Wye A.I.C. Rating: Branch Panel: LP2 1 ADDENDUM NO. 2 4-11-17 1