Loading...
HomeMy WebLinkAbout17050100 Building PlansDie Repair Power Box LAB 40' X 24' MAINT 41' X 42' Paint Office Rest Room 9'4" X 8' Rest Room 6'9" X 8' 7'3" X 8' Paint Line 81' X 11' Chemicals 48" X 40" 277/480VAC POWER LATHE FAB TABLE MILL DRILL STEEL RACK CABINET S. GRINDER BOLT BINS CABINET BOLT BINS WOMEN'S LOCKER / RR 8'-0" ACT 103 MEN'S LOCKER 8'-0" ACT 104 FINANCE OFFICE 8'-0" ACT 105 CAFETERIA 10'-0" DECK 106 RR 8'-0" 107 RR 8'-0" 108 VESTIBULE 100 CORRIDOR 8'-0" ACT 109 MEN RR 8'-0" GYP 111 OFFICE 8'-0" ACT 113 OFFICE 8'-0" ACT 114 VESTIBULE 10'-2" GYP 120 OPEN OFFICE Die Repair 7'5""X3' Power Box 14'X5' LAB 40' X 24' MAINT 41' X 42' Paint Office 9'4" X 8' Rest Room Rest Room 6'9" X 8' 7'3" X 8' Paint Line 81' X 11' Chemicals 48" X 40" 277/480VAC POWER LATHE FAB TABLE MILL DRILL STEEL RACK CABINET S. GRINDER BOLT BINS CABINET BOLT BINS WOMEN'S LOCKER / RR 8'-0" ACT 103 MEN'S LOCKER 8'-0" ACT 104 FINANCE OFFICE 8'-0" ACT 105 CAFETERIA 10'-0" DECK 106 RR 8'-0" 107 RR 8'-0" 108 VESTIBULE 100 CORRIDOR 8'-0" ACT 109 MEN RR 8'-0" GYP 111 OFFICE 8'-0" ACT 113 OFFICE 8'-0" ACT 114 VESTIBULE 10'-2" GYP 120 31'-23 8" Second Floor Demolition Plan 1/8" = 1'-0" DEMOLITION PLAN NOTES DEMOLISH EXISTING WALL CONSTRUCTION COMPLETE. DEMOLISH PORTION OF EXISTING WALL AS REQUIRED TO ACCOMMODATE NEW CONSTRUCTION. PATCH AND REPAIR ALL EXISTING SURFACES TO REMAIN. SHORE UP EXISTING STRUCTURE AS REQUIRED. REMOVE EXISTING DOOR, FRAME, AND HARDWARE COMPLETE. PROTECT EXISTING COLUMN DURING ALL PHASES OF CONSTRUCTION. REMOVE EXISTING PLUMBING FIXTURE COMPLETE. PREPARE EXISTING SUPPLY AND DRAIN LINES TO RECEIVE NEW PLUMBING FIXTURE. COORDINATE WITH PLUMBING DRAWINGS. NEW OPENING IN EXISTING MASONRY WALL. REFER TO PLAN AND ELEVATIONS AS REQUIRED. SHORE STRUCTURE DURING DEMOLITION. NOT USED. REMOVE ALL EXISTING SUSPENDED CEIILING GRID, ACOUSTICAL TILE, AND /OR LIGHT FIXTURES. RETAIN LIGHT FIXTURES FOR REUSE. REFERENCE CEILING PLAN. REMOVE EXISTING CASEWORK. REMOVE EXISTING FLOORING. PREPARE FOR NEW FINISHES. DEMOLISH EXISTING STAIR. SAWCUT AND REMOVE CONCRETE AS REQUIRED FOR ELEVATOR PIT. SEE SECTIONS A400. REMOVE EXISTING PLUMBING FIXTURE COMPLETE. REMOVE EXISTING WINDOW COMPLETE. First Floor Demolition Plan 1/8" = 1'-0" DASHED LINES INDICATE DEMOLITION WORK THIS AREA TAKE CARE DEMOLISHING CHASE DURING DEMOLITION. CONTACT ARCHITECT IF IMPEDIMENTS AFFECTING DESIGN ARE DICOVERED. 4'-8" 15'-0" 35 8" 14'-3" 4'-5" 37'-11 1 8" 8'-8" 14'-10" 21'-3" 17'-23 8" 8'-31 8" 3'-0" 1'-6" CONFERENCE VARIES ACT 201 OPEN OFFICE 1 8'-0" ACT 202 IT OFFICE 8'-0" ACT 203 MECH 8'-0" ACT 204 WOMEN 8'-0" ACT 205 MEN 8'-0" ACT 206 OPEN OFFICE 2 8'-0" ACT 207 TRAINING 7'-5" ACT 208 STORAGE 8'-0" ACT 209 MECH 8'-0" ACT 210 MECH 8'-0" ACT 211 4'-3" 5'-9" 7'-9" HOISTWAY 8" 8" 35 8" 3 5 8" 8'-0" ACT 103 8'-0" ACT 104 8'-0" ACT 105 10'-0" DECK 106 8'-0" 107 8'-0" 108 100 8'-0" ACT 109 8'-0" GYP 111 8'-0" ACT 113 8'-0" ACT 114 10'-2" GYP 120 11'-6" ACT 116 8'-0" ACT 117 122 8'-0" ACT 112 8'-0" ACT 115 8'-0" ACT 114A 31'-23 8" 8'-0" ACT 102B 8'-0" ACT 102 8'-0" ACT 101 D D D D D D D D D D D VARIES ACT 201 8'-0" ACT 202 8'-0" ACT 203 8'-0" ACT 204 8'-0" ACT 205 8'-0" ACT 206 8'-0" ACT 207 7'-5" ACT CONFERENCE 201 OPEN OFFICE 1 202 IT OFFICE 203 MECH 204 WOMEN 205 MEN 206 OPEN OFFICE 2 207 TRAINING 208 STORAGE 209 MECH 210 MECH 211 4'-3" OFFICE 212 OFFICE 213 OFFICE 214 OFFICE 215 OFFICE 216 OFFICE 217 CORRIDOR 218 7'-2" 9'-6" 6'-5" 5'-9" 7'-9" HOISTWAY 31'-23 8" 8" 8" 8" 8" Second Floor Finish Plan 1/8" = 1'-0" TBD JOHNSONITE GENERAL FINISH PLAN NOTES FINISH PLAN NOTES FINISH LEGEND CEILING FINISH WALL FINISH FLOOR FINISH REMARKS COLUMN - 5'-0" 45 8" 1. COORDINATE EXACT MANUFACTURER, TYPE, AND COLOR WITH OWNER/ TENANT. 2. USE ALL UPPERCASE CHARACTERS. 3. WALL MOUNTED SIGNAGE TO BE LOCATED ON LATCH SIDE OF DOOR SWING. MOUNT AT 60" TO CENTERLINE OF SIGN FROM FLOOR. REVIEW SPECIFIC REQUIREMENTS W/ SIGNAGE CONSULTANT. NOTE: 24 36" 42 48" CLEAR C 18" 30" 60" CLEAR L L C 54" MIN 39"-41" 32" CLEAR 5/8" 10" 6" 5/8" 10" 6" Second Floor Kitchenette 1/4" = 1'-0" A B15 SB36 REFRIGERATOR BY TENANT 18"x 18" STAINLESS STEEL DROP IN SINK, GOOSENECK FAUCET, LEVER CONTROLS PL2 COUNTER AND BACKSPLASH PL1 PL1 WIRE PULLS MICROWAVE BY TENANT SATIN FINISH 30 GFCI GFCI 30 15 36 TENANT FURN. CONTRACTOR INSTALLED Conference 201, IT 203 1/4" = 1'-0" Women's Restroom 205 1/4" = 1'-0" FINISH FLOOR +7'-0" A.F.F. ROUGH OPENING +10'-2" A.F.F. FINISH FLOOR +8'-0" A.F.F. FINISH CEILING +23'-4" A.F.F. TOP OF MASONRY 4'-0 3/4" FINISH FLOOR +10'-2" A.F.F. FINISH FLOOR +8'-0" A.F.F. FINISH CEILING +23'-4" A.F.F. TOP OF MASONRY Elevator Section Scale: 1 2" = 1'-0" Elevator Section Scale: 1 2" = 1'-0" 1 HOUR RATED CONCRETE MASONRY UNIT WALL ASSEMBLY, SEE PLANS AND WALLTYPES FOR FURTHER INFORMATION ELEVATOR SUMP PIT AND COVER, SEE PLUMBING AND STRUCTURAL DRAWINGS STEEL PIT LADDER, PAINTED. PROVIDE FLAT BAR RAILS AND FLAT BAR STEPS. SILL ANGLE AT EACH HOISTWAY OPENING, CONFIRM FINAL SIZE AND LOCATION WITH SELECTED ELEVATOR MANUFACTURER LIGHT SWITCH, SEE ELECTRICAL DRAWINGS PROVIDE FLUID APPLIED WATERPROOFING AT ALL ELEVATOR PIT FOUNDATION WALLS. PROVIDE WATERSTOP AT CONCRETE POUR JOINTS, SEE STRUCTURAL ELEVATOR HOIST BEAM, SEE STRUCTURAL DRAWINGS. CONFIRM SIZE WITH ELEVATOR MANUFACTURER. CONCRETE ELEVATOR PIT FOUNDATION; REFER TO 4" CONCRETE SLAB W/ VAPOR STRUCT. DWGS. BARRIER OVER GRANULAR FILL - REFER TO STRUCT. DWGS. EXISTING STEEL BEAM AT ROOF EXISTING "Z" PURLIN METAL ROOF ASSEMBLY 3'-6" 2'-10" 21'-3" 5'-8" 4'-8" Stair Section Scale: 1 2" = 1'-0" STEEL STAIR WITH GRATING AT TREADS AND LANDINGS HAND RAIL AT BOTH SIDES OF STAIR RUNS GUARDRAIL MOUNTED TO TOPS OF STRINGERS REMOVEABLE GUARDRAIL AREA (MINIMUM 3' WIDE) SUBMIT STRUCTURAL DRAWINGS FOR REVIEW. ALL DIMENSIONS ARE NOMINAL. GLAZING CONTRACTOR TO SUBMIT HARDWARE SUPPLIER TO VERIFY HARDWARE SCHEDULE W/ TENANT. HARDWARE FINISH TO MATCH EXISTING; COORDINATE WITH TENANT. PROVIDE BEST LOCKING SYSTEM OR APPROVED EQUAL. PROVIDE HARDWARE IN SETS ACCORDING TO THE FOLLOWING SCHEDULE: WD T S AL PL P HM GL WOOD TEMPERED STEEL PLASTIC LAMINATE HOLLOW METAL ALUMINUM PLASTIC GLASS SHOP DRAWINGS FOR REVIEW BY ARCHITECT. B. A. NO. MAT'L ELEV. ROOM SIZE NAME DOOR GLASS LOUV. MAT'L ELEV. FRAME RATING HEAD JAMB SILL DETAIL UL HARDWARE TYPE REMARKS 3 HINGES 1 LEVER LATCHSET (OFFICE) 1 LEVER LOCKSET (PRIVACY) 1 LEVER LOCKSET (STOREROOM) HARDWARE SET 1 EACH TO HAVE: 3 HINGES 1 DOOR CLOSER 1 WALL STOP 3 HINGES EACH TO HAVE: HARDWARE SET 4 1 WALL STOP EACH TO HAVE: HARDWARE SET 3 3 HINGES 1 LEVER LATCHSET (PASSAGE) 1 WALL STOP EACH TO HAVE: HARDWARE SET 2 1 WALL STOPS TO DOOR CLEARANCE A. THIS SHALL BE A DESIGN / BUILD PROJECT. HVAC SUBCONTRACTOR WILL COORDINATE FINAL DESIGN FOR ARCHITECT'S REVIEW. B. THE MECHANICAL SYSTEMS SHALL BE TESTED, ADJUSTED, AND BALANCED BY THE MECHANICAL CONTRACTOR. TESTS SHALL DETERMINE QUANTITATIVE PERFORMANCE OF EQUIPMENT; BALANCING SHALL PROPORTION FLOWS WITHIN THE DISTRIBUTION SYSTEM ACCORDING TO SPECIFIED QUANTITIES. C. ALL WORK SHALL MEET ASHRAE 90.1 (2007), THE CURRENT INDIANA ENERGY CODE. D. HVAC SYSTEM SHALL BE DESIGNED TO MAINTAIN A MINIMUM INDOOR AIR TEMPERATURE OF 72 DEGREES IN THE HEATING SEASON AND A MAXIMUM OF 72 DEGREES IN THE COOLING SEASON. E. DISCONNECTS SHALL BE PROVIDED FOR ALL EXTERIOR HVAC EQUIPMENT, LOCAETD WITHIN LINE OF SIGHT OF PERMANENT EQUIPMENT. F. WATHERPROOF RATED CONVENIENCE OUTLET WITHIN 25 FEET OF PERMANENT EXTERIOR HVAC EQUIPMENT. RECEPTACLES SHALL HAVE WEATHER-PROOF COVER IN WET LOCATIONS SO THAT RECEPTACLE REMAINS WATERTIGHT WHILE A CORD IS PLUGGED IN. G. VENTILATION AND TEMPERATURE CONTROL SHALL CONSIST OF A 7 DAY WALL MOUNTED PROGRAMMABLE THERMOSTAT. H. INSTALL IN DUCT SMOKE DETECTORS PER CODE. THEY SHALL INTERLOCK THE DX UNIT TO SHUT DOWN UPON DUCT DETECTOR ACTIVATION. PROVIDE A VISIBLE AND AUDIBLE SIGNAL AT A CONSTANTLY ATTENDED LOCATION WHICH INDICATES ACTIVATION OF THE SMOKE DETECTOR. VERIFY IF LANDLORD REQUIRES A CONNECTION TO THE EXISTING BUILDING FIRE ALARM SYSTEM. I. ALL EQUIPMENT SHALL BE INSTALLED STRICTLY ACCORDING TO MANUFACTURER'S INSTRUCTIONS. J. SUPPORTS FOR ALL EQUIPMENT AND PIPING SHALL PROVIDE ADEQUATE SLOPE AND ANCHORAGE, CONTRACTOR SHALL USE HANGARS, RODS, AND INSERTS INSTALLED, CONSTRUCTED, AND SPACED PER MSS REQUIREMENTS. ROOF MOUNTED EQUIPMENT SHALL BE LOCATED IN AREAS HAVING SUFFICIENT STRUCTURAL SUPPORT. K. SEAL ALL PENETRATIONS THRU WALLS, FLOORS, AND CEILINGS AIR, WATER, AND FIRE TIGHT. L. PROVIDE ACCESS PANEL FOR ALL CONCEALED EQUIPMENT, FIRE DAMPERS, ETC. M. INSTALL ALL PIPEWORK AND DUCTING AS HIGH AS POSSIBLE. ROUTE DUCTS AND PIPES PARALLEL AND PERPENDICULAR TO WALLS UNLESS OTHERWISE NOTED. PERFORMANCE REQUIREMENTS FOR HVAC 7'-4" HOISTWAY PROPOSED ELEVATOR CONFERENCE VARIES ACT 201 OPEN OFFICE 1 8'-0" ACT 202 IT OFFICE 8'-0" ACT 203 MECH 8'-0" ACT 204 WOMEN 8'-0" ACT 205 MEN 8'-0" ACT 206 OPEN OFFICE 2 8'-0" ACT 207 TRAINING 7'-5" ACT 208 STORAGE 8'-0" ACT 209 MECH 8'-0" ACT 210 MECH 8'-0" ACT 211 4'-3" 5'-9" HOISTWAY 7'-9" 8" 8" 10'-2" OFFICE 7'-5" ACT 212 OFFICE 7'-5" ACT 213 OFFICE 7'-5" ACT 214 OFFICE 7'-5" ACT 215 OFFICE 7'-5" ACT 216 OFFICE 7'-5" ACT 217 CONFERENCE VARIES ACT 201 OPEN OFFICE 1 8'-0" ACT 202 IT OFFICE 8'-0" ACT 203 MECH 8'-0" ACT 204 WOMEN 8'-0" ACT 205 MEN 8'-0" ACT 206 OPEN OFFICE 2 8'-0" ACT 207 TRAINING 7'-5" ACT 208 STORAGE 8'-0" ACT 209 MECH 8'-0" ACT 210 MECH 8'-0" ACT 211 4'-3" OFFICE 7'-5" ACT 212 OFFICE 7'-5" ACT 213 OFFICE 7'-5" ACT 214 OFFICE 7'-5" ACT 215 OFFICE 7'-5" ACT 216 OFFICE 7'-5" ACT 217 CORRIDOR 7'-5" ACT 218 31'-2 6'-5" 3 8" Provide (2) 120v circuits for elevator lights and recptacles 4'-3" Plumbing Plan 1/8" = 1'-0" GENERAL PLUMBING NOTES PLUMBING CONTRACTOR SHALL CONFIRM OR ESTABLISH SIZES OF WASTE, VENT, AND SUPPLY AS REQUIRED TO MAKE A COMPLETE AND WORKING SYSTEM. ALL WORK SHALL COMPLY WITH 2012 INDIANA PLUMBING CODE (2006 INTERNATIONAL PLUMBING CODE WITH INDIANA AMENDMENTS) THE SCOPE OF PLUMBING WORK INCLUDES FURNISHING, INSTALLING, TESTING AND WARRANTY OF ALL PLUMBING WORK SHOWN ON THE PLUMBING DRAWINGS. THIS PROJECT SHALL BE COMPLETE, OPERATIONAL AND MEET CURRENT STATE AND LOCAL CODES AND ORDINANCES IN EVERY WAY. COORDINATE WORK WITH OTHER TRADES AND CONFIRM THAT CLEARANCES AND FITTING REQUIREMENTS ARE KEPT. MATERIALS AND WORKMANSHIP: ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED AND SUPPORTED IN A FIRST CLASS AND WORKMANLIKE MANNER BY MECHANICS SKILLED IN THEIR PARTICULAR TRADES. A LICENSED PLUMBING CONTRACTOR SHALL PERFORM WORK. SANITARY SEWER SYSTEMS: PROVIDE CLEANOUTS WHERE REQUIRED, WHETHER SHOWN ON DRAWINGS OR NOT. PIPE IN GRADE BELOW FLOOR SLABS SHALL BE RIGID PVC SCHEDULE 40, TYPE 1, GRADE 1, COMPLYING WITH ASTM D2665 AND D-1784. PRESSURE TEST AND REPLACE DEFECTIVE MATERIALS AND CONNECTIONS. WASTE AND VENTS: SOIL WASTE AND VENT LINES SHALL BE PVC SCHEDULE 40, ASTM D1 795 WITH ASTM D2665 DWV SOCKET FITTINGS; OR, SERVICE WEIGHT CAST IRON, OR, AS REQUIRED BY LOCAL CODES. PROVIDE "STUDOR" AIR ADMITTANCE VALVES ON ALL REQUIRED BAR SINK EQUIPMENT. SLOPE WASTE PIPING UNIFORMLY 1 8" PER FOOT MINIMUM. SLOPE VENT PIPING TO P[REVENT CONDENSATION FROM SYSTEM. TEST SOIL, WASTE, AND VENT PIPING SHALL BE TESTED TO A MINIMUM 10 FEET OF HEAD MAINTAINED FOR A MINIMUM OF 15 MINUTES. REPLACE DEFECTIVE PIPE AND JOINTS AT NO ADDITIONAL COST TO OWNER. FLOOR DRAINS SHALL BE EQUAL TO SMITH 2010-A. FLOOR CLEANOUTS SHALL BE EQUAL TO SMITH 4021 OR 4021Y. WALL CLEANOUTS SHALL BE EQUAL TO SMITH 4710. PROVIDE AND INSTALL ALL REQUIRED OR SHOWN BACK-FLOW PREVENTERS. PLUMBING CONTRACTOR TO PROVIDE PIT FOR METER TO BE PROVIDED BY UTILITY. METER PIT TO BE LOCATED AS SHOWN ON DRAWINGS. CONTRACTOR TO PAY ANY AND ALL FEES TO TAP INTO CITY. DOMESTIC WATER SYSTEM: WATER SUPPLY LINES SHALL BE OF TYPE "L" OR"K" COPPER AS REQUIRED BY LOCAL PLUMBING CODES. ALL WATER SUPPLY LINES SHALL BE RUN UNDER FLOOR SLAB AND UP PLUMBING WALLS. SIZE WATER SUPPLY AS REQUIRED FOR BUILDING USAGE. WATER SERVICE OF 2" OR SMALLER SHALL BE OF TYPE "K" COPPER, ALL PIPING LARGER THAN 2" SHALL BE OF DUCTILE IRON PIPING WITH MECHANICAL JOINTS. BACKFLOW PREVENTERS SHALL BE INSTALLED BY STATE AND LOCAL ORDINANCES. INSTALL WATER LINES ON WARM SIDE OF CEILING INSULATION. DOMESTIC WATER DISTRIBUTION REQUIREMENTS PIPING SHALL BE SIZED TO PROVIDE A VELOCITY NOT EXCEEDING SIX FEET PER SECOND (FPS) FOR COLD AND HOT WATER SYSTEMS. INSULATION: INTERIOR COLD WATER PIPING SHALL BE INSULATED TO PREVENT CONDENSATION. INTERIOR HOT WATER PIPING SHALL BE INSULATED AS REQUIRED BY CODE AND PER THE LATEST ASHRAE STANDARD A90.1 TABLE 7.2.3 DOMESTIC WATER LINES SHALL BE OF TYPE "L" COPPER PIPING WITH ALL NECESSARY COPPER FITTINGS AND BALL VALVES. ALL PIPING BELOW GRADE SHALL PENETRATE FLOOR THRU A SLEEVE TO ISOLATE PIPING FROM CONCRETE. ALL COPPER PIPING ABOVE GRADE SHALL BE WRAPPED WITH 1 2" "ARMAFLEX" INSULATION. PROVIDE ALL NECESSARY FITTINGS, VALVES, WATER STOPS, ANCHORS, HANGARS, AND MISC. FOR A COMPLETE SYSTEM. INSTALLATION OF ALL PIPING SHALL CONFORM TO ALL APPLICABLE STATE AND LOCAL CODES. CHLORINATE ENTIRE DOMESTIC WATER SYSTEM PRIOR TO USE OF POTABLE WATER. VALVES: PROVIDE ACCESSIBLE CHECK VALVES IN THE INDIVIDUAL COLD AND HOT WATER FIXTURE SUPPLY LINES SERVING MIXING VALVE TYPE FAUCETS OR ASSEMBLIES HAVING HOSE CONNECTION OUTLETS THAT ARE NOT EQUIPPED WITH INTEGRAL CHECK STOPS. PROVIDE LINE SHUT-OFF VALVES AT LOCATIONS REQUIRED FOR PROPER OPERATION, SERVICING, AND TROUBLESHOOTING OF THE DOMESTIC WATER DISTRIBUTION SYSTEM AND CONNECTED COMPONENTS. LOCATIONS SHALL INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING: AT EACH FIXTURE AND PIECE EQUIPMENT, AT EACH BRANCH TAKE-OFF FROM MAINS, AT THE BASE OF EACH RISER, AT EACH BATTERY OF FIXTURES, WHERE RECOMMENDED BY EQUIPMENT MANUFACTURERS AND AT STRATEGIC LOCATIONS TO ALLOW FOR SECTIONAL ISOLATION WHILE LIMITING DISRUPTION OF SERVICES. ALL VALVES SHALL BE ACCESSIBLE FOR OPERATION AND SERVICING. TRAP PRIMING DEVICES THAT REPLY UPON LINE PRESSURE DIFFERENTIAL FOR ACTIVATION ARE NOT ALLOWED. DOMESTIC HOT WATER SYSTEMS: DOMESTIC HOT WATER SYSTEMS SHALL BE INSTALLED TO REASONABLY ASSURE THE EXPEDITIOUS FLOW OF HOT WATER TO ALL OUTLETS WITHIN 10 SECONDS. WATER SHALL BE 110 DEGREES MAXIMUM AT OUTLETS. CONTAMINATION PROTECTION: INSTALLATION OF DOMESTIC WATER SYSTEMS SHALL AVOID ALL CROSS CONNECTIONS AND ELIMINATE THE POSSIBILITY OF WATER CONTAMINATION. ON EACH WATER SUPPLY SERVING A FIXTURE WHERE A DISCHARGE LINE PROVIDES AN OPPORTUNITY WHERE CROSS CONTAMINATION COULD OCCUR, PROVIDE A VACUUM BREAKER OR BACKFLOW PREVENTER. CONNECT HW SUPPLY TO EXTG. W.H. PLUMBING CONTRACTOR TO VERIFY EXTG. SIZE IS SUFFICIENT. PROVIDE LOCAL DISCONNECT WITHIN LINE OF SIGHT. 2" Sanitary Riser Diagram NTS HW HW HW HW HW HW HW HW HW HW HW HW HW HW HW HW HW HW HW RESTROOM PLUMBING FIXTURE SCHEDULE 4" 4" 2" 2" 2" CONNECT TO EXISTING VENT Provide GFCI Recpectacle, W/P light and Switch in elevator pit DPS‘Y fed from MDP Second Floor Power Plan 1/8" = 1'-0" First Floor Power Plan 1/8" = 1'-0" AREA OF WORK SYMBOL LEGEND CORRIDOR 7'-5" ACT 218 3 8'-0" ACT 103 8'-0" ACT 104 8'-0" ACT 105 10'-0" DECK 106 8'-0" 107 8'-0" 108 100 8'-0" ACT 109 8'-0" GYP 111 8'-0" ACT 113 8'-0" ACT 114 10'-2" GYP 120 11'-6" ACT 116 8'-0" ACT 117 6'-5" 122 8'-0" ACT 112 8'-0" ACT 115 8'-0" ACT 114A 31'-23 8" 8'-0" ACT 102B 8'-0" ACT 102 8'-0" ACT 101 D D D D D D D D D D D Second Floor Lighting Plan 1/8" = 1'-0" First Floor Lighting Plan 1/8" = 1'-0" AREA OF WORK FIXTURE SCHEDULE 2'x2' LED Lay In 1'X4' Surface Mounted LED Recessed LED Down Light Exit /EM Two Head Combo Exterior Egress Light 2'x4' LED Lay In Highbay Lithonia IBH1800LM GENERAL ELECTRICAL NOTES TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE COMCHECK Track Lighting WAC Terminator II Model 1014, white Axis LED Pendant Mount 3' White or Equal Exit with Battery Backup 12" MINIMUM 18" MINIMUM CLEARANCE TO DOOR 4" MINIMUM CLEARANCE TO DOOR F1 F2 ALUMINUM FRAME A D2 A WELDED FRAME D1 F3 COMMON AREA D3 F4 HOLLOW METAL DOOR FRAME - PAINTED. REFERENCE SCHEDULES DOUBLE METAL STUD @ EACH HEAD & JAMB SEALANT CONTINUOUS @ PERIMETER, EACH SIDE STUD ANCHORS (2) SCREWS MINIMUM, EACH ANCHOR 3/4" FIRE TREATED PLYWOOD ROOFING MEMBRANE HM DOOR SHOWN REFERENCE DOOR SCHEDULE SEALANT CONTINUOUS @ PERIMETER, EACH SIDE BATT INSULATION REFERENCE PLAN STUD ANCHORS (2) SCREWS MINIMUM, EACH ANCHOR HOLLOW METAL DOOR FRAME - PAINTED. DOUBLE METAL STUDS @ EACH HEAD & JAMB HM DOOR SHOWN REFERENCE DOOR SCHEDULE REFERENCE SCHEDULES HOLLOW METAL DOOR FRAME SEALANT DOOR ANCHORS (3) PER HEAD VERIFY W/ MANUFACTURER GROUT HEAD SOLID SEALANT CONT. METAL DRIP EDGE CONTINUOUS NOMINAL HOLLOW METAL DOOR FRAME SEALANT DOOR JAMB ANCHORS (3) PER JAMB VERIFY W/ MANUFACTURER SEALANT C.M.U. BOND BEAM NOMINAL 8 X 8 16 1 1/2" GROUT JAMBS SOLID 8 X 8 16 FLASHING PER MANUFACT. RECOMENDATIONS C.M.U. BOND BEAM REFERENCE FLOOR PLAN FOR STUD SIZE REFERENCE FLOOR PLAN FOR STUD SIZE REFERENCE PLANS MOLDED POLYSTYRENE INSERT FOR C.M.U. - R4 INSULATION 5/8" GYPSUM BOARD TYPICAL, EACH SIDE REFERENCE PLAN 5/8" GYPSUM BOARD REFERENCE PLAN PRE-FINISHED METAL SHIELD ROOF FLASHING OVER SHIELD WOOD WHERE OCCURS F5 D4 NO. TYPE OF GLASS DESCRIPTION GL3 CLEAR GLASS 1/4" CLEAR TEMPERED GLASS SCHEDULE DOOR - REFER TO INTERIOR FRAMES HOLLOW METAL SCHEDULE STEEL FULLY WELDED - PAINTED GL3 2'-0" 6" 6'-6" 2" 2" FLASHING TIE-IN BETWEEN WALL AND METAL ROOF ROOFING MEMBRANE OVER TOP OF ELEVATOR DOG HOUSE AND DOWN SIDES - TIE IN WITH METAL ROOFING FLASHING ROOFING MEMBRANE OVER TAPERED INSULATION OVER 3 1 2" POLYISO INSULATION ON METAL DECK SUPPORTED BY STEEL BEAMS EXISTING STEEL BEAMS AND JOISTS LAY-IN CEILING PROVIDE BENT PLATE AND METAL DECK AT FLOOR - INFILL CONCRETE FLOOR HOISTWAY ENTRANCE DOOR AND FRAME SILL ASSEMBLY BY ELEVATOR MANUFACTURER STEEL ANGLE 4" x 5" x 3 8" REFER TO STRUCT. DWGS. 8" BOND BEAM AT HEAD OF HOISTWAY ENTRANCE ELEVATOR SUMP PIT AND COVER, SEE PLUMBING AND STRUCTURAL DRAWINGS EXISTING 8" CMU WALL CONSTRUCTION EXISTING PRECAST FLOOR/STRUCTURE 1 HOUR RATED CONCRETE MASONRY UNIT WALL ASSEMBLY, SEE PLANS AND WALLTYPES FOR FURTHER INFORMATION EXISTING STEEL BEAM AND CONCRETE FLOOR ASSEMBLY LAY-IN CEILING 1 HOUR RATED CONCRETE MASONRY UNIT WALL ASSEMBLY, SEE PLANS AND WALLTYPES FOR FURTHER INFORMATION STEEL PIT LADDER, PAINTED. PROVIDE FLAT BAR RAILS AND FLAT BAR STEPS. 4" CONCRETE SLAB W/ VAPOR BARRIER OVER GRANULAR FILL - REFER TO STRUCT. DWGS. ELEVATOR HOIST BEAM, SEE STRUCTURAL DRAWINGS. CONFIRM SIZE WITH ELEVATOR MANUFACTURER. METAL ROOF ASSEMBLY FLASHING TIE-IN BETWEEN WALL AND METAL ROOF ROOFING MEMBRANE OVER TOP OF ELEVATOR DOG HOUSE AND DOWN SIDES - TIE IN WITH METAL ROOFING FLASHING ROOFING MEMBRANE OVER TAPERED INSULATION OVER 3 1 2" POLYISO INSULATION ON METAL DECK SUPPORTED BY STEEL BEAMS EXISTING CONCRETE FLOOR - REMOVE AND REPLACE AS REQUIRED EXISTING WALL FOOTING - CUT TO ALLOW INSTALLATION OF ELEVATOR PIT AND FOUNDATION SUPPORT CONCRETE FOUNDATION AND HELICAL ANCHORS REFER TO STRUCTURAL DRAWINGS Not Used Detail at Masonry Opening 1 1 2"" = 1'-0" PLATE 3 8" X 6" X 8" EXISTING CONCRETE MASONRY UNITS (STACKED BOND) (2) 3 8" DIAMETER EPOXY BOLTS W 8 X 18 W/ 3 8" X 7 1 2" PLATE x CONTINUOUS TOP (FOR OPENINGS UP TO 6'-0") W 8 X 24 W/ 3 8" X 7 1 2" PLATE X CONTINUOUS TOP (FOR OPENINGS UP TO 8'-0") FILL WITH GROUT NOTE: CONTRACTOR TO PROVIDE TEMPORARY SHORING OF WALL DURING CONSTRUCTION. REBAR DOWELED INTO SOLID CORE OF EXISTING PLANK FLOORING - IF NOT SOLID GROUT SOLID GRAB BAR- 42"L X 1 1/4" DIA 3700 X 42 ASI OR EQUAL C 34" A.F.F. DOUBLE ROLL DISPENSER AUTOMATIC HAND DRYER ASI 20199 SEMI RECESSED OR EQ. 18" TO DISPENSOR 48" A.F.F. TO TOP OF UNIT L ACCESSORY SCHEDULE GRAB BAR- 36"L X 1 1/4" DIA MIRROR SOAP DISPENSER 3700 X 36 ASI OR EQUAL ASI OR EQUAL 9343 42" AFF CL 34" A.F.F. COAT HOOKS CL 4'-6" A.F.F. ASI OR EQUAL 0620 24 X 36 GRAB BAR- 18"L X 1 1/4" DIA 3700 X 18 ASI OR EQUAL VERTICAL ASI OR EQUAL 20031 SEMI REC. ASI OR EQUAL 8425 40" MAX TO BOTTOM Men's Restroom 206 1/4" = 1'-0" Conference Room Kitchenette 1/4" = 1'-0" B15 SB36 REFRIGERATOR BY TENANT 18"x 18" STAINLESS STEEL DROP IN SINK, GOOSENECK FAUCET, LEVER CONTROLS PL2 COUNTER AND BACKSPLASH PL1 PL1 WIRE PULLS SATIN FINISH MICROWAVE BY TENANT 30 GFCI GFCI 30 36 B15 B30 30 30 B24 - - - ROOM NAME ROOM NUMBER ENTRY - 101 - FINISH REMARKS 1. FLOOR FINISH VARIES. FINISH MATERIALS SCHEDULE DESIGNATION MANUFACTURER COLOR NAME CPT1 COLOR NUMBER NOTES P1 P2 VB1 1 EXISTING FINISHES TO REMAIN P3 A. ALL FLOORING TRANSITIONS SHALL OCCUR BENEATH THE CLOSED DOOR. PROVIDE TRANSITION STRIPS PER MANUFACTURER'S STANDARDS. B. ALL PAINT TO BE SHERWIN WILLIAMS EMERALD OR EQUIVILANT ZERO VOC INTERIOR LATEX. SATIN FINISH UNLESS OTHERWISE NOTED. C. HOLLOW METAL DOOR AND FRAMES TO BE PAINTED - P4 D. ALL FLOORING LOCATIONS TO RECEIVE VINYL BASE - VB1 ACT1 2 E-1 SEALED CONCRETE TBD AS NOTED 4" BASE CARPET TILE TBD TBD SHERWIN WILLIAMS SHERWIN WILLIAMS SHERWIN WILLIAMS TBD E-2 EPOXY PAINT NOTE: FINISHES SHALL MEET ALL CLASS A FIRE RATINGS AND COMPLY WITH CHAPTER 8 OF THE INTERNATIONAL BUILDING CODE. CPT2 TBD CARPET TILE CPT2 TBD CARPET TILE P4 SHERWIN WILLIAMS TBD P5 SHERWIN WILLIAMS TBD 2 X 4 COMMODITY GWB HARD LID T-1 CERAMIC TILE VCT-1 VINYL TILE TBD TBD First Floor Finish Plan 1/8" = 1'-0" CPT-1 ACT1 P1 CPT-2 ON EXISTING STAIR ETR - - ETR - ETR CPT-1 ACT1 P1 - - - CPT-1 ACT1 P1 - - - CPT-1 ACT1 P1 - - - ETR - - ETR - ETR VCT-1 ACT1 P1 - - - ETR - - ETR - ETR T-1 ACT1 P1 - - - FIRST FLOOR FINISHES TO MATCH EXISTING CPT-2 ACT1 P1 - - - CPT-2 ACT1 P1 - - - - - - T-1 CPT-1 CPT-1 VCT-1 ETR - - ETR - ETR ETR - - ETR - ETR ETR - - ETR - ETR ETR - - ETR - ETR ETR - - ETR - ETR ETR - - ETR - ETR ETR - - ETR - ETR T-1 CPT-1 208 8'-0" ACT 209 8'-0" ACT 210 8'-0" ACT 211 4'-3" 7'-5" ACT 212 7'-5" ACT 213 7'-5" ACT 214 7'-5" ACT 215 7'-5" ACT 216 7'-5" ACT 217 7'-5" ACT 218 NOTE: ALL NEW LIGHTING TO BE LED. SEE E200 FOR LIGHTING INFORMATION GENERAL CEILING NOTES B. E. A. ALL WALLS EXTEND TO 6" ABOVE CEILING UNLESS NOTED AS FOLLOWS: DRAWINGS FOR EXACT SPECIFICATIONS AND VERIFICATION LIGHT FIXTURE AND DIFFUSERS ON DRAWINGS SHOWN FOR LOCATION ONLY. COORDINATE WITH MECHANICAL AND ELECTRICAL THE MAIN PORTION OF ANY ROOM OR SPACE, UNLESS NOTED CENTER ACOUSTICAL CEILING PANELS IN EACH DIRECTION WITHIN OTHERWISE. OF QUANTITY. WALLS TO CEILING GRID WALLS TO JOISTS ABOVE WALLS TO DECK ABOVE G J D C. PROVIDE LIKE CEILING TILES IN EACH ROOM TO CREATE UNIFORM LOOK D. PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLANS ARE FOR REFERENCE F. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT LAY-OUT LIGHTING PLACEMENT AND QUANTITIES ARE FOR REFERENCE ONLY. AND TOTAL WATTAGE MEETS ASHRAE 90.1 STANDARDS G. ASHRAE 90.1. TENANT TO APPROVE TYPE. ALL SWITCHES ARE TO BE MOTION SENSOR CONTROL PER INDEPENDENTLY AT EACH CORNER OR ATTACHED TO THE CEILING GRID GRID MOUNTED TROFFERS ARE TO BE SUPPORTED DIRECTLY AND USING RATED GRID CLIPS AT EACH CORNER. H. G G D GYPSUM BOARD BULKHEAD @ 7'-0" Second Floor Plan 1/8" = 1'-0" First Floor Reflected CeilingPlan 1/8" = 1'-0" Second Floor Plan 1/8" = 1'-0" G G D G WORK THIS AREA ETR ETR ETR D D D D ETR ETR ETR ETR ETR ETR ETR GYPSUM BOARD BULKHEAD @ 7'-0" 16'-41 4" 12'-0 1 2" 21'-6 5 8" 47'-8 1 2" 35 8" 21'-10 3 8" 23'-117 8" 47 8" 14'-75 8" 47 8" OFFICE 7'-5" ACT 212 OFFICE 7'-5" ACT 213 OFFICE 7'-5" ACT 214 OFFICE 7'-5" ACT 215 OFFICE 7'-5" ACT 216 OFFICE 7'-5" ACT 217 CORRIDOR 7'-5" ACT 218 8'-51 2" 35 6'-6" 8" 3 5 8" 8'-4" 35 8" 6" 6'-6" 26'-11" 1'-21 2" 7'-2" 9'-6" 6'-5" 5'-9" 7'-9" HOISTWAY 31'-23 8" 8" 8" 8" 8" Second Floor Plan 1/8" = 1'-0" WALL TYPE LEGEND W3 W2 W1 3-5/8" X 20 GA. METAL STUDS AT 16" O.C. WITH 5/8" GYPSUM WALLBOARD EACH SIDE AND SOUND ATTENUATION BLANKETS IN EACH STUD CAVITY. USE MOISTURE RESISTANT TYPE ON TOILET ROOM SIDE OF WALLS TYP. NOT USED. 3-5/8" X 20 GA. METAL STUDS AT 16" O.C. WITH 5/8" GYPSUM WALLBOARD ONE (1) SIDE . USE MOISTURE RESISTANT TYPE ON TOILET ROOM SIDE OF WALL. 6" X 20 GA. METAL STUDS AT 16" O.C. WITH 5/8" GYPSUM WALLBOARD EACH SIDE AND SOUND ATTENUATION BLANKETS IN EACH STUD CAVITY. 8" CONCRETE MASONRY WALL SEE STRUCTURAL DRAWINGS FOR VERTICAL REINFORCING FURR OUT WALL WITH 2 1 2" METAL STUDS AND 5 8" GYPSUM WALLBOARD EXISTING WALL CONSTRUCTION TO REMAIN. W4 W5 W6 * PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT ALL "WET" LOCATIONS. * ALL WALL TYPES EXISTING UNLESS NOTED. PLAN NOTES 1 ALIGN NEW WALL CONSTRUCTION WITH EXISTING. NEW CASEWORK. SEE 01, 04 /A300. PROVIDE NEW PLUMBING FIXTURES. REFERENCE 3,5/A300. PROVIDE NEW TOILET ROOM ACCESSORIES. SEE 3,5/A300. REFER TO 4/A400 FOR DETAILS AT MASONRY OPENING. NEW ELEVATOR. SEE SECTIONS 1,2/A400. REFER TO STRUCTURAL DRAWINGS S1.1, S2.1, S2.2 SHAFT OPEN TO STORAGE ROOM BELOW. NEW DOOR ON EXISTING FRAME. NEW METAL STAIR SEE 1 /A401. PROTECT EXISTING STRUCTURE DURING ALL PHASES OF CONSTRUCTION. NOT USED. EXISTING STAIR AND HANDRAIL TO REMAIN. NOT USED. NO WORK THIS ROOM. 2 3 4 5 6 7 8 9 10 EX 11 12 13 14 First Floor Plan 1/8" = 1'-0" DN UP 2 1 W1 W1 W1 EX W4 W1 W1 W1 W1 W1 W6 HATCHED WALLS = NEW CONSTRUCTION 1 5 6 6 7 8 8 8 9 9 10 W1 3 4 DN 12 AREA OF WORK W6 W6 W1 W6 W4 W4 W1 W6 W6 EX 1 W5 W5 W6 2 EX EX EX EX EX EX EX EX EX EX EX EX EX EX EX 14 14 14 14 14 14 14 8 EX 10 10 OPEN OFFICE 11'-6" ACT 116 PHONE 8'-0" ACT 117 PHONE 8'-0" ACT 118 PHONE 8'-0" ACT 119 MANUFACTURING 23'-5" DECK 121 MANUFACTURING 26'-4" DECK 118 RECEIVING 26'-4" DECK 119 6'-5" STORAGE 122 STOCK 8'-0" ACT 112 CONFERENCE 8'-0" ACT 115 CLOSET 8'-0" ACT 114A 5'-9" 7'-9" HOISTWAY 31'-23 8" 8" 8" 8" 8" CONFERENCE RM 8'-0" ACT 102B DISPLAY AREA 8'-0" ACT 102 LOBBY 8'-0" ACT 101 CONFERENCE VARIES ACT 201 OPEN OFFICE 1 8'-0" ACT 202 IT OFFICE 8'-0" ACT 203 MECH 8'-0" ACT 204 WOMEN 8'-0" ACT 205 MEN 8'-0" ACT 206 OPEN OFFICE 2 8'-0" ACT 207 TRAINING 7'-5" ACT 208 STORAGE 8'-0" ACT 209 MECH 8'-0" ACT 210 MECH 8'-0" ACT 211 4'-3" 5'-9" 7'-9" HOISTWAY 8" 8" OFFICE 7'-5" ACT 212 OFFICE 7'-5" ACT 213 OFFICE 7'-5" ACT 214 OFFICE 7'-5" ACT 215 OFFICE 7'-5" ACT 216 OFFICE 7'-5" ACT 217 CORRIDOR 7'-5" ACT 218 8'-51 2" 35 6'-6" 8" 3 5 8" 8'-4" 35 8" 6" 6'-6" 26'-11" 1'-0" CODE SUMMARY 1 SCOPE OF WORK REMODEL OF EXISTING OFFICE SPACE - DEMOLITION OF WALLS - 2 OCCUPANCY CLASSIFICATION F 1- FACTORY, B - BUSINESS 3 CHANGE OF OCCUPANCY CLASS? NO 7 BUILDING AREAS (SF) 8 TOTAL PROJECT AREA 5,832 SF REMODELING 9 OCCUPANCY CALCULATIONS B OCCUPANCY SPACE AREA SF PER OCCUPANT OCCUPANT LOAD FIRST FLOOR 5776 SF 100 58 10 EGRESS WIDTHS 12 SPRINKLER SYSTEM (YES/NO) YES - EXISTING TO REMAIN SECOND FLOOR 5,237 SF 100 LIFE SAFETY NOTES 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORN/STROBES) EMERGENCY SPEAKERS, SMOKE DETECTORS, FORE PULLS, AND ANY OTHER REQUIRED ALARM AND DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). 3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE WORKING SYSTEM. SODA IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING.MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO VISIBLE EXTINGUISHER. GENERAL NOTES REFER TO SHEET A200 FOR WALL TYPE . APPLICABLE BUILDING CODES ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE SPECIFICATIONS & DRAWINGS AND SHALL SATISFY ALL APPLICABLE CODES, ORDINANCES, A.D.A., AND REGULATIONS OF ALL GOVERNING BODIES INVOLVED. ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE CONTRACTOR INVOLVED. THE FOLLOWING CODES AND REGULATIONS ARE CURRENTLY ADOPTED BY THE STATE OF INDIANA AT THE TIME THE BUILDING PERMIT IS APPLIED FOR: BUILDING CODE: INDIANA BUILDING CODE 2014 (INTERNATIONAL BUILDING CODE 2012 WITH INDIANA AMENDMENTS) MECHANICAL CODE: INDIANA MECHANICAL CODE 2014 (INTERNATIONAL MECHANICAL CODE 2012 WITH INDIANA AMENDMENTS) ELECTRICAL CODE: INDIANA ELECTRICAL CODE 2009 (NATIONAL ELECTRICAL CODE 2008 WITH INDIANA AMENDMENTS) PLUMBING CODE: INDIANA PLUMBING CODE 2012 (INTERNATIONAL PLUMBING CODE 2006) FIRE CODE: INDIANA FIRE CODE 2014 (INTERNATIONAL FIRE CODE 2012 WITH INDIANA AMENDMENTS) ENERGY CODE: INDIANA ENERGY CONSERVATION CODE 2010 (ASHRAE 90.1-2007 WITH INDIANA AMENDMENTS) FUEL GAS CODE: INDIANA FUEL GAS CODE 2014 (INTERNATIONAL FUEL GAS CODE 2006 WITH INDIANA AMENDMENTS) ACCESSIBILITY CODE: INDIANA BUILDING CODE 2014, CHAPTER 11 ICC A117.1 ACCESSIBLE USABLE BUILDINGS AND FACILITIES, 2009 EDITION. INDIANA ADMINISTRATIVE CODE 675 IAC 13-2.6-13 CATEGORY STRUCTURAL FRAME EXTERIOR BEARING WALLS EXTERIOR NON-BEARING WALLS INTERIOR BEARING WALLS INTERIOR NON-BEARING WALLS (PARTITIONS) FLOOR / FLOOR-CEILING ASSEMBLY ROOFS / ROOF-CEILING ASSEMBLY EXIT ACCESS CORRIDORS EXIT STAIR ENCLOSURES SHAFT ENCLOSURES (ELEVATOR / MECHANICAL) MIN. FIRE RESISTANCE 0 HOUR - TABLE 601 0 HOUR - TABLE 601 / 602 0 HOUR - TABLE 601 / 602 0 HOUR - TABLE 601 0 HOUR - TABLE 601 0 HOUR - TABLE 601 0 HOUR - TABLE 601 0 HOUR - TABLE 1017.1 (WITH SPRINKLER) 0 HOUR - SECTION 1020.1 (LESS THAN 4 STORIES) 0 HOUR - SECTION 707.4 (LESS THAN 4 STORIES) EXISTING BUILDING B OCC. FIRST TOTAL SECOND EXISTING BUILDING F1 OCC. 5,776 5,237 11,013 68,751 -- 68,751 NUMBER OF REQ. EXITS 2 11 CONSTRUCTION TYPE II-B (FULLY SPRINKLERED) 52 2 SPACE INCHES PER OCCUPANT INCHES REQUIRED FIRST FLOOR .15 18 SECOND FLOOR .15 INCHES PROVIDED 540 (EXCEED) 5 72 (EXCEED) OCCUPANT LOAD 120 31 FIRE RESISTIVE REQUIREMENTS - TYPE II-B F1 OCCUPANCY FIRST FLOOR 68,751 SF 300 229 2 B OCCUPANCY FIRST FLOOR 38 .15 6 108 (EXCEED) F1 OCCUPANCY S1 OCCUPANCY FIRST FLOOR 15 .15 2 108 (EXCEED) 4 GROSS BUILDING AREA 79,764 SF 5 REMODEL AREA (INC. IN GROSS) 5,237 SF SECOND FLOOR + 595 SF FIRST FLOOR = 5,832 SF 6 ALLOWABLE AREA ALLOWABLE AREA CALCULATIONS NOT REQUIRED, NO ADDITIONAL SQUARE FOOTAGE ADDED FIRE EXTINGUISHER KEY EXISTING FIRE EXTINGUISHERS TO REMAIN PER 2012 IFC WITH 2014 INDIANA AMENDMENTS Life Safety Second Floor Plan 1/32" = 1'-0" EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT Life Safety First Floor Plan 1/32" = 1'-0" SHADED AREA = AREA OF NO WORK EXIT EXIT FIRST FLOOR AREA OF WORK 11'-6" ACT 116 PHONE 8'-0" ACT 117 PHONE 8'-0" ACT 118 PHONE 8'-0" ACT 119 MANUFACTURING 23'-5" DECK 121 MANUFACTURING 26'-4" DECK 118 RECEIVING 26'-4" DECK 119 STORAGE 122 STOCK 8'-0" ACT 112 CONFERENCE 8'-0" ACT 115 CLOSET 8'-0" ACT 114A 5'-9" 7'-9" HOISTWAY 31'-2 3 8" 8" 8" 8" 8" CONFERENCE RM 8'-0" ACT 102B DISPLAY AREA 8'-0" ACT 102 LOBBY 8'-0" ACT 101 HORTON, INC. second floor remodel / elevator 201 WEST CARMEL DRIVE CARMEL, indiana GENERAL PROJECT NOTES VICINITY MAP DRAWING INDEX PROJECT PARTICIPANTS KEY PLAN NTS AREA OF WORK PROJECT SCOPE