HomeMy WebLinkAbout44-98 ADLS Blockbuster Large Format.18G�N�R4L CON57RIUC71 ON SPEC I f22 I CA71 ONS - BUILDING SHELL
2.02 TRAPS ON CAST IRON PIPE 5HALL BE SERVICE KEE64T CAST IRON.
TRAPS ON 'TRADED PiPE SHALL BE CAST IRON DRAINAGE PATTERN
TYPE. TRAP' ON COPPER PIPE SHALL BE CAST BRONZE. ALL
TRAPS ACCESSIBLE SHALL #AVE CLEAN OUT PLU65.
2.03 CLEANOUT5
A. CLEANOUTS LOCATED IN FLOOR SHALL BE SET BELOW FLOOR
SLAB AND BE COVERED WITH A SEPARATE SCREW FASTENED PLATE AND
FRAME SET FLUSH WITH FINISHED FLOOR SLAB; PLATE AND FRAME SHALL
HAVE NICKEL BRONZE FINISH WITH SOMATEED TOP LIKE WADE MODEL
A --logo. INSTALL CARPET RINGS IN CARPETED AREAS.
PART 3: INSTALLATION
3.01 HORIZONTAL 501L AND WASTE PIPIN6 SHALL BE INSTALLED AT A
UNIFORM &RADE AS NOTED ON PLANS OR NOT LE55 THAN ALLOWABLE BY
INDIANA PWM51% CODE FOR CORRE5PONDI% PIPE 51ZE5, VENT PIPIN6
SHALL BE 6RADED TO PROVIDE VIENTiN6 OF THE PL01-,6N6 AND TO BE
FREE OF CONIX3eATiON.
3.02 CLEANOUTS SHALL BE INSTALLED IN SEWER AND WASTE LINES
WHERE SROM ON THE DRAWIN65 AND A5 REGUJIRED BY THE PLUM BIN& CODE
AND/OR FIELD CONDITIONS. CLEANOUTS SHALL BE PROVIDED AT THE
BASE OF EACH SOIL AND WASTE STACK, AT INTERVALS OF 50' MAXIMUM
IN STIRA16HT RUNS, AT EACH 04AN6E IN DIRECTION AND AT THE END OF
ALL BRANCHES.
A. CLEANOUT5 SHALL CONSIST OF PROPER DRAINAGE FITTING
COMPONENTS TERMINATED WITH FERRULE AND BRASS COUNNTEER5 W SGRE N
PLUG. CLEANOUT5 IN WALLS OF FINISHED SPACE5 AND FLOORS SHALL BE
CONTANED WITHIN A FLUSH NICKEEL. BRONZE FINISH CLEANOUT BOX AND
THOSE IN FLOOR SHALL HAVE SC.ORATEED SURFACE. INSTALL CARPET
RIN65 IN CARPET® AREAS.
B. CLEANOUTS SHALL BE OF THE SAME SIZE A5 THE PIPE UP TO
4'. ALL CLEANOUTS SHALL BE 50 LOCATED AS TO PROVIDE EASY
RODDING. CLEANCUIM N41014 ASI£ ABOVE INACCE55I511LE CEILW75 OR
OTHER INAGGESSIBL E AREAS SHALL BE INSTALLED BEHNO ACCESS
PANELS. ALL CLEANOUTS SHALL BE ACCESSIBLE.
3.03 ALL PLUMBiN6 VENTS SHALL BE INCREASED ONE PIPE SIZE BEFORE
PASSING THROUGH THE ROOF. EXTEND 12' MINIMUM ABOVE ROOF. VENT5
THROUGH ROOF SHALL BE FLASHED AND WITH 4 POUND
9-EET LEAD TURNO DOWN IN51DE VENT AND EXTENDING AT LEAST IS'
UNDER ROOFING. ALL SEAMS SHALL BE SEALED WITH PURE LEAD.
MINIMUM SIZE= OF 5" THRU ROOF.
5.04 EACH FIXTURE AND PIECE OF EQUIPMENT REQUIRING CONC)CoTiON5
TO THE SOIL AND WASTE SYSTEM SHALL BE EQUIPPED WITH A CODE
APPROVED TRAP. THE TRAP SHALL BE PLACED AS, NEAR TO THE FIXTURE
AS POSSIBLE AND NO FIXTURE SHALL BE DOUBLE TRAPPED.
3A5 PIPE PA551N6 THROUGH BUILDING WALL SHALL BE CAULKED WATER-Ti6HT,
3.06 EXTEND INSIDE PiPE MATERIAL AT LEAST 5' FROM BUILDING
BEFORE CHANGING TO OUTSIDE PIPE MATERIAL.
3A? SOIL AND WASTE PIPING SHALL BE PLU66M AND SUBJCCTED TO A
TEST OF MINIMUM 10 EBT WATER HEAD PRESSURE AND MAINTAINED FOR
FOUR HOURS WITH NO LEAGA6E,
SECTION 16004
R aA REMENTS OF 'I - E ELEGTRI GAL 6-eciNTRACTOR
PART I: GENERAL
1.01 SAMPLES
A. CONTRACTOR SHALL SUBMIT SAMPLES OF ANY MATERIAL OR
EQUIPMENT HEMN 50 REWE;STEED BY THE ENSIMEEER
B. EACH SAMPLE SHALL BE LABELED TO INDICATE NAME OF
PROJECT, NAME OF CONTRACTOR MANUFACTURER, BRAND, JOB NUMBER
AND FEDERAL SPECIFICATION OR ASTM NAMiBER WHERE REQUIRED.
G. IN THE EVENT THE SAMPLE 15 OF SUCH A NATURE THAT IT I5
MORE PRUDENT TO INSPECT SAME AT THE MANUFACTURERS FACILITY OR
AT AN EXISTING INSTALLATION, SIGH DISPLAY SHALL BE MADE AT NO
ADDITIONAL EXPENSE TO THE OWNER OR EN61NEHt
1.02 CODES, LAMS, ORDINAW-ES, PERMITS, i FEES
A. ALL INSTALLATIONS SHALL COMPLY WITH THE LATEST
EDITIONS, 15SUIE2 OR SUPPLEMENTS OF ALL APPLICABLE CODES,
ORDINANCES, RESULATIOMS AND REQUIREMENTS WITHOUT INCREASE IN
CONTRACT PRICE. THIS SHALL INCLUDE RULES AND REGULATIONS OF
FIRE PREVENTION AND BUILDING SAFETY COUNCIL OF INDIANA, INDIANA
STATE FIRE MARSHAL, ELECTRIC SAFETY ORDERS OF THE STATE OF
INDIANA; ALL FEDERAL, STATE, AND LOCAL AND MUNICIPAL ORDINANCES.
SUCH PROVISIONS, RHES, REOUL.ATION5 AND ORDINANCES ARE TO BE
CONSIDERED AS MUCH A PART OF THESE SPECIFICATIONS A5 IF REPEATED
HEREIN OR ATTACHED HERETO. ALL CHANGES OR MODIFICATIONS
REQUIRED TO CONFORM TO SUCH CODES, REGM ATION5 OR REWIREMENT5
MUST BE APPROVED, THE SAME AS SHOP Di MN&S, BY THE EEN&INER
B. THE NATIONAL. ELECTRICAL CODE SHALL BE THE MINIMUM
REQUIREMENT FOR ALL ELEGTRCAL INSTALLATIONS UNLESS AMENDED BY
LOCAL CODES, REGULATIONS, AND ORDINANACES OF ALL OTHER
AUTHORITIES HAVING JURISDICTION SHALL ALSO APPLY TO THIS CONTRACT.
G. THIS CONTRACTOR SHALL GIVE ALL NECZ55ARY NOTICES,
OBTAIN AND PAY FOR ALL PERMITS AND PAY ALL 6OVERMhENTAL TAXES,
FES FOR STREET CUTS, AND OTHER COSTS IN CONNECTION NTH HIS
WORK, AND HE SHALL MAINTAIN AND PAY ANY SPECIAL CHARSES,
OVERTIME, OR PROVIDE ANY SPECIAL PROTECTION, BARRICADES, LIGHTS,
F SONMEL AS MAY BE REQUIRED BY THE CITY AND/OR STATE IN THE
OF THE CONTRACT REQUIFdD-V'NT5 AS NE LL A5 PROVIDING
THE NECESSARY EQUIPMENT TO V16 OR DRIVE OR BY MEANS OM16NATIED
50 A5 TO COMPLY KITH THE 60VERMINS BODIES' PROCEDURES.
D. ALL MATERIALS F9URN15HEeD AND ALL WORK INSTALLED SHALL_
COMPLY KITH THE RULES AND RECOMMENDATIONS OF THE NATIONAL BOARD
OF FIRE LWERKRITER5, WITH A1. RBZIRV-eM OF THE LOCAL UTILITY
COMPANIES, WITH THHE REG�DATIONS OF THE FIRE INSURANCE RATING
ORGANIZATION HAVING JURISDICTION, AND KITH THE REQUIREMENTS OF
ALL 6OVERNMENTAL DEPARTMENTS HAVING .JURISDICTION.
E. THE RULES AND REGULATIONS OF THE OCCUPATiONA. SAFETY
AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR SHALL BE
C0NSID9RED AS MUCH A PART OF THESE SPECIFICATIONS A5 IF REPEATED
HEREIN OR ATTACHED HERETO.
F. THE NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION
'STANDARD OF INSTALLATION' SHALL. BE THE MINIMUM KORKMANSHEP STANDARD.
6. THE ELECTRICAL CONTRACTOR AT COMPLETION OF THE
PROJECT, SHALL FURNISH A FINAL INSPECTION CERTIFICATE FROM THE
LOCAL ENSPEGTIN6 AITHORITY.
IAL ROYALTIES AND PATENTS
A. THE GONTTRAGTOR SHALL PAY ALL ROYALTIES AND SHALL
Dl�ENO ALL SUITS OR CLAMS FOR INIFRiN&EMENT5 OF ANY PATENT
RI&HT5 AND SHALL SAVE THE OA ER AND EeN61NEER HARMLESS, FROM LASS
ON ACCOUNT.
1.04 V151TIN6 THE PREMISES
A\ THE CONTRACTORS ARE DIRECTED TO V151T THE PREMISES AND
MAKE THEMSELVES THHOROU6HILY FAMILIAR WITH THE 6ENERAL LAYOUT OF
THE BUILDING SITE AND THE LOCATION OF PRESENT LINES TO AHICH
CONNECTIONS SHALL BE MADE.
B. HE SHALL ALSO CHECK PRESENT GRADIS, DITCI`IES,
PAVEMENTS, 56"ERS, AND/OR ALL OTHER CONDITIONS AFFECTI146 THE
SERVICE INSTALLATIONS CONTEMPLATED UNDER THE CONTRACT.
C. .SUCH OFFSETS A5 MAYBE REQUIRED TO LEAVE NEW WORK
CLEAR ETC„ MUST BE INCLUDED IN THE CONTRACTORS PROPOSAL, AND
THE CONTRACTOR MUST A-cejME THE FULL RESPONSIBILITY FOR HAVING
MADE A PROPER AND THOROU614 INVE5T16ATION OF THESE REQUIREMENT5.
105 THE CONTRACTOR SHALL PROVIDE A MINIMUM OF 46 HOURS
ADVANCED NOTICE TO ARGHITiECT/ENGINER OF ANY REQUIRED TE5TIN&.
PART 2: PRODUCTS
2.01 MATERIALS
A ALL MATERIALS SHALL BE NEW AND BEAR THE MANUFACTURERS
NAME, TRADE NAME AND THE UL LA3E1. IN EVERY CASE WEREA STANDARD
HAS BEEN ESTABLISHED FOR THE MATERIAL.
S. MATERIALS SHALL BE DELIVER TO THE SITE AND STORED IN
ORIGINAL CONTAINERS SUITABLY SHELTERED FROM THE ELEMENTS, BUT
READILY ACCESSIBLE FOR INSPECTION BY THE EN61NEER UNTIL
INSTALLED. ALL ITEMS SUBJECT TO MOISTURE DAMAGE SHALL BE STORED
IN DRY, HEATED SPACES.
C. MATERIALS OF THE SANE 6EN RAL TYPE 5HALI- BE OF THE
SAME MAKE THRou6HOVT THE WORK TO PROVIDE UNIFORM APPEARANCE,
OPERATION AND MAINTENANCE.
2.02 PROTECTION OF PROPERTY, MATERIALS, AND WORK
A THIS CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING
ALL PROPERTIES OF WHATEVER DESCRIPTION LYIN6 WITHIN THE SCOPE OF
THE PROJECT FROM DAMAGE RESULTING FROM, OR INCIDENTAL TO, THE
PROSECUTION OF THIS CONTRACT. LIKENISE, THIS CONTRACTOR SHALL
BE OBL16® TO PAY FOR ALL SUCH DAMAGE OR A5 MAY BE CAUSED BY THE
NECESSARY REMOVAL OF E.XI5TIN6 OBSTRUCTIONS WHICH MAY OCCUR
DLIKINoS THE F'ROvRE55 OF THE WORK.
B. ALL PiPE ENDS, AND PARTS OF EQUIPMENT LEFT UNCOVERED
SHALL BE GAPPED, PL UeeED, OR OTHERWISE PROPERLY PROTECTED TO
PREVENT DAMAGE OR THE IWRL51ON OF FOREI6N MATTER,
C. DAMA6E OR DEFECTS DEVELOPime BEFORE AC.CEPTANGE OF THE
WORK SHALL BE MADE GOOD AT THE CONTRACTORS EXPENSE.
D. MANUFACTURERS DIRECTIONS SHALL BE FOLLOWED COMPLETELY
IN THE DELIVERY, STORA6E, PROTECTION, AND INSTALLATION OF ALL
EQUIPMENT AND MATERIALS.
E MATERIALS STORED SHALL BE DISTRIBUTED TO AVOID
OVERLOADING OF THE STRUCTURAL. FRAME, AND SHALL NEVER BE
CONCENTRATED IN SUCH A MAfR A5 TO EXCEED THE EQUIVALENT OF
FIFTY (50) POUNDS PER SQUARE FOOT UNIFORMLY DISTRIBUTED LOADING.
F. STORED MATERIALS SHALL BE MOVED AT THE CONTRACTORS
ZXPENSE I F THEY INTERFERE WITH THE PROGRESS OF THE WORK
PART 3: INSTALLATION
LAi AL" 1=RNATE EWIPME NT
A CONTRACTORS ARE HEREBY ADVISED THAT ALTERNATE LIGHTING
"IXTURE PAGKA6m, OTHER THAN THOSE SPECIFIED ON CONTRACT
DOCUMENTS, MAY BE BID. NOTICE 15 HEREBY GIVEN THAT SHOULD ANY
FIXTURE SUBMITTED A5 SHOP DRAWINGS, BE REJECTED A5 NOT EQUAL IN
PERFOF44ANC,E, APPEARANCE, ETC., THE CONTRACTOR KILL BE REWIRED
TO PROVIDE THE EXACT FIXTURE AS SPECIFIED IN THE CONTRACT DOCUMENTS.
B. WHERE EQUIPMENT REQL)IRIN6 DIFFERENT ARRAN&e EENT OR
CONNECTIONS FROM THOSE SHOH N 15 APPROVED, IT SHAH BE THE
RESPONSIBILITY OF THE CONTRACTOR TO INSTALL THE EQUIPMENT TO
OPERATE PROPERLY AND IN HARMONY KITH ALL TRADES WITH THE INTENT
OF THE DRAWINGS AND SPECIFICATIONS.
C. IF THE PROP05M INSTALLATION 15 APPROVED, THE
CONTRACTOR SHALL MAKE ALL INCIDENTAL 0HAN6E5 IN PIPING,
DUGTNORK, SUPPORTS, INSULATION, NIRIN6, HEATERS, PANELBOARD5,
ETC. HE SHALL PROVIDE ALL ADDITIONAL MOTORS, GONTROLLEiR5,
VALVES, FIT7iN65, AND OTHER ADDITIONAL EQUIPMENT AND LABOR
REQUIRED FOR THE PROPER INSTALLATION AND OPERATION OF THE SYSTEMS
RESULTING m;to I THE SELEGTiON OF ALTERNATE EQUIPMENT ,
GUUIPM NT, INGLUDIN:S
ALL REWIRED CHANGES IN AFFECTED TRADES.
D. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER
LOCATION OF ROU6HIN& IN AND COWECTiOML BY OTHER TRADES. AL
CHANGES SHALL BE MADE AT NO INCREASE IN THE CONTRACT AMOUNT OR
ADDITIONAL COST TO THE OTHER TRADES.
3.02 CONTRACTOR RESPONSIBILITIES
A. EXPEDITE WORK OF INSTALLIN6 MAIN SERVICE AND OTHER
WORK NECESSARY 50 THAT THE HEATING SYSTEM MAY BE OPERATED WHEN
REQUIRED AS DIRECTED BY THE OMER.
B. THE EL. SHALL STUDY ALL ARCHITECTURAL, STRLUGTURAL,
MECHANICAL, PLUIM11BIN6 DRAWINGS, SHOP DRANIN65, CATA06 CIT5, ETC.,
TO DETERMINE HON EQUIPMENT, FIXTiJRES, PIPING, DUCTWORK, ETC.,
ARE TO BE SUPPORTED, FIT THE SPACE AVAILABLE WITH PROPER ACCE55
MOUNTED OR SUSPENDED AND SHALL PROVIDE EXTRA 5TESL BOLTS, BEAMS,
INSERTS, PIPE STANDS, BRA0Z 15 AND ACC.E 5 ORIELS FOR PROPER
SUPPORT H-EiH132 OR NOT SHOWN ON DRAKIN65.
3.03 CUTTIN6 AND PATCHING
A. THE E.G. SHALL BE RE51*0N515LE FOR ALL GUTTING,
FITTING, OR PATCHING OF H15 WORK WHICH MAY BE REQUIRED TO MAKE
ITS SEVERAL. PARTS COME T06ETKR PROPERLY AND FIT IT TO RECEIVE
OR BE RECEIVED BY WORK OF OTHER CONTRACTORS.
B. PATCHIN6 OF ALL OPEENIN66 FOR NEIN INSTALLATIONS AND ALL
OPENINGS RAE LTEN6 FROM THE REMOVAL OR RJ:LOCATION OF ANY
INSTALLATION OF EQUIPMENT SHALL BE DONE NTH MATERIALS OF LIKE
TYPE ADJOINING OPENIN65 AND AS APPROVED BY THE ARCHITECT.
5.04 EXCAVATION ADN BACKFILL
A. THE E.G. SHALL BE RESPONSIBLE FOR ALL EXCAVATION
(INCLJUDIN6 SAFETY BRACING, ETCj AND BAGKFILLINN6 REQUIRED FOR
THE INSTALLATION OF HIS WORK.
B. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMA6E TO
51DEKALKS, PAVING, DRIVES, LA 4K TOPSOIL, ETC., CAUSED BY THE
E)WnON OF THIS CONTRACT. DAMAGED ITEMS SHALL BE REPAIRED OR
RESTORED TO ORIGINAL CONDITION.
3.05 OPE AT10N AND MAINTENANCE MANUALS
A. GONRACTOR SHALL DELIVER TO EN61N ER FOUR (4) COMPLETE
SETS OF MAINTENANCE AND OPERATIN6 INSTRUCTIONS PERTAININ6 TO HIS
EQUIPMENT, IN THE REAR OF THESE BOOKS, HE SHALL INCLUDE A
COMPLETE COPY OF ALL SHOP DRAWIN65. EACH OF THE FOUR SETS SHALL
BE BOUND IN HARD COVER BOOKS AND INDEXED AS TO ITE M5.
3.06 SHOP PRAHM66
A. THI5 CONTRACTOR SHALL SUBMIT TO EN61NEM FOR APPROVAL
ELECTRICAL ITEMS INTENDED TO BE USED ON PROJECT; SE SCHEDULE IN
SECTION 16005.
3.01 EACH CONtRACTOR SHALL MAINTAIN A SET OF DRAWIN&S IN HIS
JOB 51TE OFFICE OR SHED, ON WHICH HE SHALL RECORD LOCATIONS OF
ALL WORK INSTALLED. ALL WORK ADDED OR REVISED SHALL BE
RECORDED. DRAAKIN65 SHALL BE USED EXCLUSIVELY FOR THIS PURPOSE
AND KEPT UP-TO-DATE WITH PR06RESS OF NORK AT THE COMPLETION OF
THE PROJECT EACH CONTRACTOR SHALL FURNISH TO THE ENGINEER A
COMPLETE SET OF 'A5 BUILT' PRANN66 ON REPRODUCIBLE 'HYLAR'.
MYLAR TO BE PROVIDED BY CONTRACTOR
5EGTION 16040
PAINTING, LABELING AND IDENTIFICATION
PART 1: GENERAL
1.01 DESCRIPTION
A LABELING AND IDENTIFICATION OF ELECTRICAL WORK SHALL
BE FLRN15HED AND INSTALLED COMPLETE AS 5HOWN ON DRAININGS AND
SPECIFIED HEREIN.
B. FIELD PAINTING OF ELECTRICAL WORK 15 IN THI5 CONTRACT,
INGLIUDIN& REPAINTING OF FACTORY FIN15HE5 WHERE REQUIRED.
C. ITEMS TO BE LABELED BUT NOT LIMITED TO THE FOLLOWING:
ALL PANELS SHALL BE IDENTIFIED AS SHOWN ON PLANS.
EQUIPMENT DISCONNECT SWITCHES SHALL BE LABELED.
ALL EQUIPMENT SHALL HAVE TA6 IDENTIFYIN6 SAME.
ALL COVER PLATE BACKS TO HAVE OIRCA)IT NUMBERS.
ALL CIRCUITS IN PANELS.
ALL WIRING WITHIN PANELS SHALL HAVE NJMIXR TA65.
PART 2: PRODUCTS
2.01 MATERIALS
A. BRADY IDENTIFICATION SYSTEM.
B. NAME PLATES SHALL BE WHITE CORE BLACK LAMINATED
PLASTIC HAVING EN&RAVEED LETTERS. LETTER 51ZE AND NOMENCLATURE
SHALL BE AS DIRECTED BY EN61MEER
PART 3: INSTALLATION
3.01 E>MOUTION
A WHEN ALL TRADES HAVE COMPLETED THEIR WORK IN ANY 61VEN
AREA, ALL FACTORY PRIME PANTED SURFACES THAT HAVE BEEN MARRED
OR DEFACED SHALL BE TOUGHED UP AND THE ENTIRE WORK SHALL BE
RESTORED FREE FROM BLEMISHES.
B. PROTECT ADJACENT WORK AND MATERIALS BY SUITABLE
FLOOR, &LASS AND OTHER SURFACES. LEAVE NORK IN A CLEAN,
ORDERLY, ACCEPTABLE CONDITION.
C. ALL. FACTORY FINISHED EQUIPMENT THAT HAS BEEN DAMASED
SHALL BE REPAJNTED IN ITS ENTIRETY AND NOT MERE3LY 'TOiJCHHE:D UP'.
SUCH STEEL OR IRON SURFACES SHALL BE PAINTED TWO COATS OF LEAD
AND OIL SEMI -61-055 ENAMEL OVER PRIME COAT IN COLOR TO MATCH
ORIGINAL.. THE EN61NEER SHALL HAVE THE FINAL DHCINON ON ANY
DAMA6ED EQUIPMENT WHETTER IT SHOULD BE F011 ACED OR REPAIRED.
SECTION 16103
EQUIPMENT CONNECTIONS
PART I: GENERAL
1.01 1 -GU I PMENT
STARTERS
DISCONNECT 5NETCHES
PART 2: PRODUCTS
2.01 STARTERS
A. MOTOR STARTERS FURNISHED BY EELECTRICAL CONTRACTOR ON
THIS PROJECT SHALL BE OF A TYPE AS GALLED FOR IN OTHER SECTIONS
OF THESE SPECIFICATIONS.
2.02 EQUIPMENT DISCONNECT SI ITCES
A. DISCONNECT SWITCHES SHALL BE FURN15HIED AND IN5TALLEED
BY THE ELECTRIOAL CONTRACTOR FOR ALL EQUIPMENT NOT FURNISHED
WITH INTEGRAL DISCONNECTS.
PART 3: INSTALLATION
3.01 PROCEDURE
A. THE E.G. SHALL FURNISH AND INSTALL ALL NECESSARY
CONDUIT, WIRE, OUTLETS, DISCONNECT SWITCHES, STARTERS, RELAYS,
AND OTHER A ZS50RIES TO WIRE -IN COMPLETELY ALL MECHANICAL
EQUIPMENT OPERATING ELECTRICALLY. THE AIRING -IN OF ALL
THERMOSTATS, CONTROL. SYSTEMS AND INTERLOCKINS OF A550CIATM
EQUIPMENT SHALL BE A PART OF THE ELECTRICAL CONTRACT.
B. THE E.G. SHALL FLIRNI514 AND INSTALL ALL STARTERS AND
CONTROLS AS SHONN ON THE DRAWINGS AND/OR REQUIRED AND WIRE -IN
COMPLETE UNLESS OTHERWI5E NOTED ON THE DRAWINGS.
Co. EQUIPMENT/CONTROL WIRING DIA6RAM5 SHALL BE PROVIDED TO
THE E.G. BY THE MECHANICAL CONTRACTOR AND/OR OTHER RESPECTIVE
CONTRACTORS FURMNISHiNG EQUIPMENT TO BE AIRED -IN.
D. ALL ROTATING EQUIPMENT AND ASSOCIATED VIBRATING BASES,
ENCLOSURES, ETC., SHALL BE ISOLATED I" THE CONDUIT SYSTEM BY
USE OF FLEXIBLE CONDUIT. THE LBd6TH OF THE FLEXIBLE CONDUIT
SHALL BE LIMITED TO 60' OR LESS.
E. ON ALL MECHANICAL EQUIPMENT LOCATED IN FALSE CEILING
SPACES, THE DISCONNECT SWITCHES SHALL 13E MOUNTED SEPARATE FROM
THE UNITS AND CONNECTED VIA FLEXIBLE CONDUIT.
F. WHERE ITEBMiS OF EQUIPMENT ARE YEAT'HERPROOF, VAPORPROOF,
OR SIMLAR SPECIAL CONSTRUCTION, ALL CONDUITS, BOXES, FITTIN65,
ETC., EXPOSED TO THESE SAME CONDITIONS SHALL BE COMPATIBLE IN
CONSTRUCTION AND INSTALLATION WITH ITEMS OF EQUIPMENT.
SECTION 16110
CONDUIT 4 RACEWAY SYSTEMS
PART I: GENERAL.
1.01 DESCRIPTION
RJ61D STEEL (HEAVY WALLED) CONDUIT
INTERMEDIATE METAL CONDUIT
THIN WALL CONDUIT (EMT)
FLEXIBLE CONDUIT
NON-METALLIC CONDUIT
PART 2: PRODUCTS
2.01 RI61D STEEL CONDUIT (HEAVY WALU
A. RI61D STEEL CONDUITS SHALL BE INSTALLED IN THE
FOLLONIN6 LOCATIONS UNLESS HEAVY WALLED RI61D PLASTIC CONDUIT 15
INSTALLED A5 PER PARAGRAPH 2.04 OF THIS SECTION:
I. SERVICE ENTRY CONDUITS
2. UNDERGROUND CONDUITS
3. CONDUITS BELOW CONCRE'T'E ON GRADE
4. CONDUITS IN DAM' OR WET LOCATIONS
S. CONDUITS IN CORROSIVE ATMiOSPFERE
6. CONDUITS WHERE EXP05W TO WEATHER
B. CONDUIT SHALL NOT CRACK OR SPLIT NOR SHALL THE ENAMEL
OR GALVANIZING CRACK OR FLAKE NiEN BENT AT RIGHT ANS E5 TO THE
SMALLEST RADIUS ALLOYS $Y THE NATIONAL iLECTRIC,& CODE.
C. IN AREAS AIEHRE CONDUITS ARE USED TINDER CONCRETE SLABS
ON 6RADE, NO 51ZE SMALLER THAN I' TRADE 51ZE SHALL BE ALLOWED.
CONDUITS 5HALL NOT CROSS OR OVERLAY ONE ANOTHER IN THE SLAB. IN
AREM INHERE CONDUITS LAR6ER THAN I' ARE USED, THE CONDUIT SHALL
BE INSTALLED IN A 6RANULAR FILL BELON THE CONCRETE SLAB.
D. ALUMINUM CONDUIT SHALL NOT BE BURIED IN CONCRETE.
E CONDUITS INSTALLED EXPOSED ON THE SURFACE IN DAMP OR
NET LOCATIONS SHALL BE PROVIDED KITH CLAMP BACKS UNDER EACH
CONDUIT CLAMP TO PREVENT ACCUMULATION OF MOISTURE AROUND THE CONDUIT.
F. WHERE RI61D STEEL CONDUIT 15 RUN UNDERGROUND THEY
SHALL BE IN CORRO 014 RESISTANT STEL CONDUIT, ALUMINUM CONDUIT
AND/OR CORROSION RESISTANT NON-FERROUS ALLOY M61D CONDUIT AND
SHALL BE COATED KITH ASPHALT PAINT OR EPDXY GOATED. ALUMINUM
CONDUIT, WEEN BURIED IN SOIL, SHALL BE COATED KITH BITUMINOUS OR
ASPHALT BASE PAINT. ALUMINUM CONDUIT SHALL NOT BE USED IN OR
UNDER CINDER FILL.
6. UNDi R6ROLM CONDUIT RIM SHALL BE INSTALLED AT LEAST
30' BELOW GRADE. UNDE RMPOUND CONDUIT INSTALLED UNDER PAVEMENT
(PARKINS EAT) SHALL BE BACKFILLED WITH &RANULAR FILL TO A POINT
5 FET BEYOND PAVEMENT.
H. UNDERGROUND CONDUITS UNDER DRIVES AND/OR HEAVY TRAFFIC
AREAS SHALL AL50 BE ENCASED WITH 5' ENVELOPE OF CONCRETE.
2.02 THIN WALL CONDUIT (EDIT)
A. IMT OR THINKALL CONDUIT JOINTS SHALL BE GUT SQUARE
REAMED SMOOTH To R6MIOVE BURRS AND CONNECTED WITH APPROVED TYPE
COUPLING, CONNECTORS AND FITT7N65 SPECIFICALLY DESI6MED AND
MANUFACTURED FOR THE PURPOSE.
B. THIN HALL CONDUIT MAY BE USED FOR ALL BRANCH CIRCUIT
L16HTiN6 AND AUXILIARY POKER CONGEALED ABOVE CEILING, EXPOSED
HHE RE MECHANICAL INJURY 15 NOT A PROBLEM, BURIED WITHIN CONCRETE
AND IN VERTICAL WALLS ABOVE GRADE. THE CONDUIT SHALL BE UL
APPROVED ELECTRICAL METAL TUBING WITH CONCRETE T16 4T TONIC, OR
APPROVED THREADLESS FITTIN65. THIN WALL CONDUIT SHALL NOT BE
USED OVER 2' TRADE SiZE.
G. THIN WALL CONDUIT SHALL NOT BE USED UNDER CONCRETE
SLABS ON GRADE.
2.03 FLEXIBLE CONDUIT
A. FLEXIBLE CONDUIT SHALL BE RUN AT EACH MOTOR,
TRANSFORMER, OR OTHER MECHANICAL ROTATING OR VIBRATING DEVICE
RE QUIRIN6 501-E MOVEMENT. THE USE OF FLEXIBLE CONDUIT SHALL BE
LIMITED TO 60' OR LESS.
B. AHERE MOTORS ARE MOUNTED ON SLIDING BASTES, THE
FLEXIBLE CONNECTIONS SHALL BE OF SUFFICIENT LENGTH (MINIMUM 12')
TO ALLOW FILL. TRAVEL OF MOTOR ON BASE.
G. FLEXIBLE CONDUIT SHALL BE USED FOR CONNECTION OF
CONTROL EQUIPMENT REQUIRINkS PIPING, SUCH AS SOLENOID VALVES,
PR 55URE CONTROLS, AQUA5TAT5, PNEUMATiG-ELEGTRIG RELAYS , ETC.
D. IN M015T LOCATIONS OR EXP05M TO WEATHER THE FLEXIBLE
CONDUIT SHALL HAVE NEOPRENE JACKET, OR AS APPROVED BY THE
V*INEER. FLEXIBLE CONDUIT SHALL BE SEALTIGHT, OR APPROVED EQUAL.
E AT ALL LOCATIONS A ERE FLEXIBLE CONDUIT 15 USED, A
GROUND WIRE (BARE OR KITH 6REN INSULATION? SHALL BE INSTALLED
IN THE FLEXIBLE CONDUIT AND TEMRINATEED AT BOTH ENDS KiTH
APPROVED GROUNDING METHODS TO ASSURE ELEECTRGAL CONTINUITY
THROUGH THE FLEXIBLE CONDUIT. THE SIZE OF THE 6ROUNDIN6
CONDUCTOR SMALL BE IN ACCORDANCE KITH THE TABLE 250-44 OF THE MEG.
F. ALL EXCESS FLEXIBLE CONDUIT SHALL BE SUPPORTED 5UCHH
THAT IT DOES NOT LAY ON CEILINGS, EQUIPMENT, M.
2.04 NON-METALLIC, PLASTIC CONDUIT
A. NON-METALLIC PLASTIC CONDUIT MAY BE INSTALLED IN THE
FOLLOHIN6 AREAS:
I. 51ERVICE ENTRANCE BELOW 6RADE.
2. UNDERGROUND, BELOW 5LAB5, PAVED AREAS, BACKFILL TO
BE 6RANULAR
3. NHEN UNDER DRIVES, OR HEAVY TRAFFIC, AREAS, ENCASE
IN 5' ENVELOPE OF CONCRETE.
4. IN5TALL WITH &ROUND WIRE.
B. NON-METALLIC PLASTIC MAY BE INSTALLED IN HEAVY
CORROSION AREAS, iF; UNDERGROUND OR ANIMAL HOLDING AREAS.
PART 3: INSTALLATION
LAI CONDUIT INSTALLATION
A. METALLIC CONDUIT SYSTEM SHALL EE INSTALLED FOR THE
CONNECTiONLS OF ALL OUTLET BOXES, JUNCTION BOXES, PANELBOARDS,
CABINETS, DISCONNECT 5WIT04!5S, MOTOR STARTERS, TRANSFORMERS,
LIGHT FIXTURES, AUXILIARY SYSTEMS, ELECTRICALLY OPEEiRATED
EQUIPMENT, ETC„ AS INDICATED ON THE DRANN65 AND HEREIN SPECIFIED.
B. INSTALLATION OF METALLIC CONDUIT SHALL BE DONE
EXPERTLY TO PROVIDE A FIRM MECHANICAL ASSEMBLY AND ELEGTRGAL
CONDUOTI V 1TY.
G. ALL CONDUIT SHALL BE RUN CONGEALED CONTINUOUS FROM
OUTLET TO OUTLET, FROM OUTLET TO CABINETS, PULL OR JUNCTION
BOXES, ETC., KITH A MINIMUM NUMBER OF BENDS.
D. THE NUMBER OF BENDS PER RUN SHALL CONFORM TO THE
NATIONAL ELECTRICAL CODE LIMITATIONS.
E. BENDS OR OFFSETS SHALL BE MADE NTH STANDARD CONDUIT
ELLS, HUB TYPE, CONDUIT FITTIN65 OR BY FIELD FORMIN6 THE CONDUIT.
ALL FIELD BENDS 5 4ALL 13E MADE KITH STANDARD TOOTS AND EQUIPMENT
MANUFACTURED ESPECIALLY FOR THIS PURPOSE.
MEGH./LEG.
F. CONDUITS SHALL BE OF SIZES NOTED ON PLANS OR R XIRE D
BY THE NATIONAL ELECTRICAL CODE FOR THE NUMBER AND SIZES OF
CONDUCTORS INDICATED. EXCEPT AS NOTED OTHERWISE, OR INLUDED
HEREIN, THE MINIMUM SIZE SHALL BE I/2' TRADE SIZE CONDUIT
PROVIDED THERE WILL BE SPARE CAPAOITY REMAININ6 TO
INSTALL TWO M12 TW WIRES.
6. CONCEALED CONDUITS SHALL BE RUN IN A DIRECT LINE K1TH
LONG SWEEP BE05 AND OFFSETS.
H. CONDUITS INSTALLED UNDER FLOOR SLABS AND UNDER&ROUND
CONSTRUCTION SHALL BE FIRMLY SECURED IN PLACE BEFORE THE POURING
OF THE CONORETE SLAB OR CONDUIT ENCA5EMENTS.
I. CONDUIT ENDS 54ALL BE CAPPED TO PREVENT ENTRANCE OF
FOREIGN MATERIALS DURING CONSTRUCTION.
J. EXP05M CONDUIT SHALL BE RUN PARALLEL TO AND AT RIGHT
ANGLES TO BUILDING LINES.
K. WHERE OUTLETS ARE SPECIFICALLY CALLED TO BE EXPOSED ON
WALLS, 9" OUTLETS SHALL BE FED VERTICALLY FROM THE CONDUIT
INSTALLED IN THE CEILING SPACE. IF ANOTHER OUTLET 15 TO BE FED
FROM THIS CONDUIT FEED, A JUNCTION OR PULL BOX SHALL BE INSTALLED
iN CEILING SPACE AND A SIN6LE CONDUIT SHALL BE FED DOWN TO THE
EEXPO5ED OUTLET.
L. CONDUIT SHALL BE SEGUREL.Y FASTENED IN PLACE ON NOT
MORE THAN V INTERVALS BY USE OF APPROVED 5UPPORTIN6 DEVICES.
M. ALL CONDUIT AND OUTLET SUPPORTING DEVICES SHALL BE A
TRADE PRODUCT MANUFACTURED AND DE516NED FOR THE 5PECIFIC
APPLICATION SUCH AS CADDY CLIPS, RODS, OLAMP5, STRAPS, U14I5TRLUT,
ETC. WIRE ADN BENT -NAIL TYPE INSTALLATIONS SHALL NOT BE AN
ACCEPTABLE METHOD FOR SUPPORTING CONDUIT AND OUTLET.
N. EACH CONDUIT SYSTEM SHALL BE INSTALLED COMPLETE BEFORE
CONDUCTORS ARE PULLED IN.
0. WHERE FIELD CONDIT1ON5 REQUIRE INDICATED CONGEALED
CONDUIT TO BE RUN EXPOSED, APPROVAL OF THE ENGINEER MUST BE
SECURED BEFORE INSTALLATION. NO CHANNFLIN& OR CUTTING OF FACE
OF BLOCK TYPE WALL5 WILL BE PERMITTED FOR THE INSTALLATION OF
CONDUIT'S.
P. AREAS WARE IT 15 OBVIOUSLY NECESSARY FOR CONDUITS AND
DUCTWORK TO OCCUPY THE SAME AREA, THIS CONTRACTOR SHALL
COORDINATE HIS CONDUIT AND OUTLET INSTALLATION WITH THAT OF THE
MECHANICAL CONTRACTOR
SECTION 16121
WIRING DEVICES
PART 1: 6ENERAL
1.01 DESCRIPTION
SPECIAL OUTLETS
FART 2: PRODUCTS
01 9- Mr.IAL lJljn,-FTS
A. SINGLE PHASE 30 TO 50 AMPERE OUTLETS AND 20 TO 50
AMPERE 3 PHASE OUTLETS AS NOTED ON SYMBOL LEGEND OR ON THE PIANS
SHALL BE DETAILED BY A SPECIFIC, TYPE OR MEMBER. WEHRE 2 OR 3
PHASE CONNEGT10N5 ARE 5HOM TO AN OUTLET LOCATION THE OUTLET
SHALL MATCH THE CAPACITY OF THE CIRCUIT. IF NO NJNIBER or-
SPECIFIC
FSPECIFIC DEVICE 15 SHOWN, THE CONTRACTOR SHALL NOTIFY THE
ENSINEEER FOR A DECISION.
PART 3: INSTALLATION
A. OUTLET LOCATIONS ARE SHOWN ON THE PLANS FOR THE
VARIOUS SYSTEMS, AND SHALL BE INSTALLED APPROXIMATELY AS 5HOKN
ON THE PLANS. THE E NSINE E R RESERVES THE R16HT TO CHANE THE
LOCATION OF ANY OUTLET V -O" IN ANY D"MOTION KITHiOUT EXTRA COST
TO THE OWNER, PROVIDING THE CHANGE I5 155UED PRIOR TO THE
INSTALLATION OF THE OUTLET.
B. THIS CONTRACTOR SHALL CONSULT THE ARCHITECTURAL.
DRAWING DETAILS, ELEVATIONS, SECTIONS, ETC. IN ORDER TO SECURE
FULL KNONLED&E AND INTENT OF THE DRANIN65, AND OBTAIN
INSTRUCTIONS FOR HEI&HTY'.
G. THIS CONTRACTOR SHALL VERIFY THE LOCATION OF KALL
PARTITIONS AND THTC QeSS FROM ARCHITECTURAL. PLANS, AND EXE94I5E
EVERY PRECAUTION TO AVOID CONFLICT M14T OTHER OUTLETS AT SAME
LOCATION ON OPPOSITE SIDE OF WALL BY MEANS OF OFF5ETTiNG, OR AS
DIRECTED. ALSO, VERIFY THE DOOR 5KIN65 AND OTHER CONSTRUCTION
THAT WILL AFFECT IN ANY WAY THE PROPER LOCATION OF S^ITGHES OR
CENTERING OF OUTI..ET5 IN PANELING, ETC.
D. IN THE EVENT OF CONFLICT BETKEENN PRAMN66 REGARDING
LOCATIONS OR ELECTRICAL OUTLETS, THE ELECTRICAL CONTRACTOR SHALL
NOTIFY THE E%IM !M
SECTION 16151
CONDUIT F I TTI NGS, BOXES, ETC.
PART I: GENERAL
1.01 DESCRIPTION
CONDUIT FITTIN(9,5, BUSHINC75, LOCKNUT'S
OUTLET BOXES
JUNCTION OR PULL. BOXES
PART 2: PRODUCTS
2.01 CONDUIT FITTINGS, BUSHINGS, LOOKNJTS
A. ALJ.. CONDUITS V:iERE THEY UTTER PAMt£LBOARDS, PULL BOXES,
OR OUTLET BOXES SHALL BE SECURED IN PLACE BY 6ALVANIZED LOC40M
AND BUSHHIN55. THE LOGKN)T5 SHALL BE T6HTENED A&AIN5T THE BOX
WITHOUT DEFORMING THE BOX,
B. 81,51411465 SHALL BE INSTALLED AT ALL CONDUIT
TERMINATIONS TO FURNISH PROTECTION FOR WIRE INSULATION FROM ABRASION.
G. THE USE OF SINGLE LACKNUTS AND MALLEABLE OR STEEL
BUSHINGS SHALL BE LIMITED TO THIN HAZED CONDUIT (EMT) In OR
UNDER IN SIZE. CONDUITS 1-1/2' AND LARGER SHALL BE EQUIPPED
KITH INSULATED TYPE BU5HIN6 AND L.00HWTr INSIDE AND OUTSIDE THE
ENGL05URE.
D. IN HAZARDOUS L.OGATION5, 5EALIN6 FrMN55 SHAT BE
PROPERLY INSTALLED AT ALL REQUIRED LOCATIONS IN ACCORDANCE WITH
THE NATIONAL ELECTRICAL GORE AND LOCAL CODE REOULAT10N5.
2.02 OUTLET BOXES
A. OUTLET BOXES OF STANDARD PLASTIC OR CAST ALUMINUM OR
OF A PATTERN ADAPTED TO THE SPECIAL REQUIR ! ENT5 OF THE OUTLET
SHALL BE INSTALLED AT CONVENIENCE OUTLETS, OR OTHER ITEMS SHOWN
ON THE PIANS AND REEQUIRIN6 AN OUTLET BOX FOR TERMINATION.
B. ALL BOXES 54ALL HAVE MOUNTING LU&S OR EARS FOR COVERS.
RECEPTACLE OUTLETS SHALL BE PROVIDED WITH BOXES AND COVERS,
ADAPTED TO THE SPECIAL REQUIREMENTS OF THE PARTICULAR OUTLET.
G. ALL BOXES SHALL BE AT LEAST 1-1/2' DEEP, BUT 46T
CONFORM IN VOLUME TO NEC, REQUIREMENTS.
D. OUTLET BOXES FDR WIRING DEVICES IN FINISHED KALLS
SHALL BE ONE PiECE STANDARD 6AN6 TYPE OF SIZE TO ACCOMMODATE THE
NUMBER OF DEVICES NOTED.
,4RIaE4001:
STATE OP
' R
%,,CH+I T*w
C45"FIED SY:
DRAWBIG REV"
ZL MAY 4, IG48
z
3 �
*
BULDNG AGENCY S
CONS1 muc, �i a
REVISIONS
-- -------------------- -- - -
3
-- - - ---- ---- ------- - - -
-- - --- --- -----
4
FELE - DATE - T1
"16" c
FWT SCALE
V& a I'4
tie
Q
is
Z
w
Oda
Genera
Specifica'
001
PROJWT M