HomeMy WebLinkAbout03030112.1ADDITION TOS
VALUE FABRICS INC.
401 WE5T CARMEL DRIVE
CARMEL, INDIANA 4632
CARMEL DRIVE
t—
W
T
ARCHITECTURAL SITE PLAN
NOT TO SCALE
NORTH
GENERAL REQUIREMENTS
ALL WORK 15 TO BE DONE IN ACCORDANCE WITH ALL
GOVERNING CODES AND REGULATING AGENCIES.
THIS PROJECT IS DESIGNED AND DOCUMENTED PER THE ARCHITECT'S
INTERPRETATION OF THE CODE REQUIREMENTS. VARIOUS GOVERNING
AGENCIES SOMETIMES NTERF'RET THE CODES, LAWS AND ORDINANCES
DIFFERENTLY. THESE AGENCIES HAVE JURISDICTION TO REQUIRE
CHANGES N DESIGN AND CONSTRUCTION INCLUDING THOSE
AGENCIES INVOLVED WITH THE 'AMERICAN'S WITH D15A5ILITIE5 ACT'
GENERAL CONTRACTOR AND EACH SUBCONTRACTOR SHALL
SCRUTINIZE ALL DRAWING SHEETS TO DETERMINE THE FULL
EXTENT OF THE RE5PON51BIL[TIES FOR EACH TRADE.
GENERAL CONTRACTOR AND EACH 51.15CONTRACTOR SHALL
BECOME FAMILIAR WITH THE PROJECT AND BRING ANY
DISCREPANCIES BETWEEN DRAWINGS AND FIELD
CONDITION TO THE IMMEDIATE ATTENTION OF THE ARCHITECT.
CONTACT RESPECTIVE UTILITY COMPANIES FOR EXACT
LOCATION OF APPLICABLE UTILITIES AND TAKE NECE55ARY
PRECAUTIONS TO PROTECT UTILITIES BELOW GROUND AND
ABOVE GROUND AND TO NOT INTERRUPT SERVICE TO TENANT.
THE CONTRACTOR SHALL MAKE ADVANCE ARRANGEMENTS
WITH THE PROPERTY OLPtER/LANDLORD FOR ANY WORK
WHICH WILL AFFECT THE OPERATIONS OF NEARBY TENANTS.
THE CONTRACTOR SHALL MAKE ADVANCE ARRANGEMENTS
WITH THE PROPERTY OIJNER/LANDLORD FOR ANY WORK
NOT DURING NORMAL BUSINESS HOURS AND SHALL BE
RESPONSIBLE FOR SECURING THE PREMISES AT ALL TIMES.
ALL DIMENSIONS ARE NOMINAL UNLESS OTHERWISE NOTED
AND SHALL BE FROM FACE OF STUD TO FACE OF STUD
OR FACE OF MASONRY TO FACE OF MA50NRY
FOR NEW CONSTRUCTION AND FACE OF FINISH FOR
EXISTNG CONSTRUCTION. DO NOT SCALE DRAWINGS,
CONTACT ARCHITECT FOR DISPUTED DIMENSIONS.
ALL INTERIOR PARTITIONS SHALL HAVE A STC OF 48
UNLESS OTHERWISE INDICATED • PROVIDE ACOUSTIC
BATT INSULATION AND SOUND 5EALANT AT ALL INTERIOR
GYP, BD. PARTITIONS UNLESS OTHERWISE INDICATED.
ALL MATERIALS 5TORED WITHIN THE BUILDING SHALL BE
NEATLY STACKED AND SHALL NOT INTERFERE WITH
OPERATION OF THE FACILITY OR NEARBY TENANTS.
DO NOT STORE COM5U5TI5LE MATERIALS ON THE PREMISES
FOR A PERIOD LONGER THAN NECESSARY FOR EXECUTION
REMOVE AND LEGALLY DISPOSE OFF-SITE ALL
DEBRIS RESULTING FROM THE DEMOLITION AND EXECUTION
OF THE WORK.
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
OBTAINING ALL PERMITS.
THESE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT N
TERMS OF ARCHITECTURAL DESIGN CONCEPT, THE DIMENSIONS OF THE
BUILDING, THE MAJOR ARCHITECTURAL ELEMENTS, AND THE TYPE OF
STRUCTURAL SYSTEM. THE DRAWINGS DO NOT NECESSARILY INDICATE
OR DESCRIBE ALL WORK REQUIRED FOR FULL PERFORMANCE AND
COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. THE TRADE
CONTRACTORS SHALL PERFORM SUCH SERVICES, AND FURNISH ALL
ITEMS REQUIRED FOR THE PROPER EXECUTION OF THE PROJECT.
ALL OR PART OF THESE DOCUMENTS WERE GENERATED BY ELECTRONIC
MEANS. THE ARCHITECT 15 RELYING ON THE ACCURACY OF THE
SOFTWARE EMPLOYED. THE ARCHITECT'S LIABILITY 15 THEREFORE
LIMITED TO THE EXTENT CUSTOMARY IN THE INDUSTRY.
THE ERROR AND OMISSIONS DE51GN LIABILITY 15 LIMITED TO THE
COST OF CORRECTING THE DEFICIENCY.
THE GENERAL CONDITIONS FOR THIS PROJECT ARE THE GENERAL
CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, AIA DOCUMENT
A201, CURRENT EDITION, A COPY OF WHICH 15 ON FILE AND
MAY BE EXAMINED N THE OFFICE OF THE ARCHITECT.
PROJECT LOCATION
NORTH
NT5
DRAWING INDEX
TITLE SHEET / CODE INFO.
A001 GENERAL INFORMATION
STRUCTURAL DRAWINGS
F101 FOUNDATION PLAN
S101 FRAMING PLAN EXIST. BLDG.
ARCHITECTURAL DRAWINGS
A101
FIRST FLOOR PLAN
A102
SECOND FLOOR PLAN
A103
REFLECTED CEILING PLANS
A201
BUILDING ELEVATIONS
A301
BUILDING SECTION
A302
WALL SECTION
A401
INTERIOR ELEVATIONS
A601
ROOM FINISH SCHEDULE
A602
DOOR SCHEDULE
ELECTRICAL DRAWINGS
E101 ELECTRICAL POWER PLAN
E102 ELECTRICAL LIGHTING PLAN
MECHANICAL DRAWINGS
M101 MECHANICAL PLAN
PLUMB.3,?N a DRAWINGS
P101 PLUMBING PLAN
CITY OF CARMEL/CLAY TOWNSHIP
Dept. of Community Services -- Building & Code Enforcement
One Civic Square I" Floor; Carmel, IN 46032
PLAN AUTHENTICATION CERTIFICATIONS AND AGREEMENT
As the authorized agent responsible for obtaining a permit or permits', I certify that these plans
are IDENTICAL to those released for construction by the Indiana Dept. of Fire & Iluilding
Services. I also understand that if it is determined that these plans are not identical, a STOP
=z7n�;AZd
er the Ordinances referenced below.
—7ti cl i th C Toru Nt no PrP
,authorized Signature Printed Name
'Required under Chapter 7, Section 10 of the Carmel City Code, entitled "Building Code" and Scction 29.42
and Section '9.4.3 entitled "Administration Required by Carmel / Clay Township Zoning Ordinance, Section
31.1 entitled -Violations and Penalties". - _ —7 /t
S Permits/Forms,' AuthentStickerll-01 Date
CODE SUMMARY
ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS
OF THE SPECIFICATIONS 4 DRAWINGS AND SHALL SATISFY ALL
APPLICABLE CODES, ORDINANCES, ADA, AND REGULATIONS OF ALL
GOVERNING BODIES INVOLVED. ANY MODIFICATIONS TO THE CONTRACT
WORK REQUIRED BY SUCH AUTHORITIES SHALL BE AT THE EXPENSE OF THE
TENANT, SUBJECT TO THE RECEIPT OF AN AFFIDAVIT OR LETTER FROM THE
GOVERNING BODY AND TENANT'S PRIOR APPROVAL OF ANY ADDITIONAL
TIC7N COST TO BE INCURRED. ALL PERMITS AND LICENSES NECESSARY FOR
EST CARI'•1£L DRIVE FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED AND PAID
IEL., INDIANA FOR BY THE CONTRACTOR INVOLVED.
APPLICABLE CODES INCLUDE, BUT ARE NOT LIMITED TO THE FOLLOWING:
FIRE CODE 1991 UFC WINDIANA AMENDMENTS - 1998 IFC
BUILDING CODE 1991 UBC W/NDIANA AMENDMENTS - 1998 IBC
PLUMBING CODE 1991 UPC W/INDIANA AMENDMENTS - 1999 IPC
MECHANICAL CODE 1996 INTERNATIONAL MECHANICAL CODE - 1998 IMC
ELECTRICAL CODE 1999 NFPA 10 WINDIANA AMENDMENTS - 1998 IEC
ADA CODE
CHAP 11 OF 1991 UBC W/NDIANA AMENDMENTS - 19W IBC CHAP II
CONSTRUCTION TYPE
OCCUPANCY TYPE
AREA OF EXISTING FIRST FLOOR 12,826 SQ FT
AREA OF EXISTING SECOND FLOOR 1,459 50 FT
AREA OF ADDITION PER FLOOR 2,981 50 FT
TOTAL SQUARE FOOTAGE OF ADDITION 5,914 5Q FT
```111111111/4
•�`� N PEl
��p15TEREh',
o:
* AR195001
sMIE v
/',�����ili1►��
P E T E R
ARCHITEC
984 Logan Street Suite 10 Nobler
t e 1 3 1 7 7 7
f a x 3 1 7 7 7
email alndio0peIeraona
0
z
0
Q
wMATTIN
CORPORA
10150 LANTERN ROAD,
FISHERS, INDIANA
317-577-96E
CC
L
a:
01
Q
LL
LL
on"MEMO
CONSTRUCTION
FEBURARY
REVISIONS
QRDAE
BION
REVISION
2
DATE
REVISION
3
DATE
DATE
ZL
A5REVISIO
DATE
PLOT DATE:
DRAWN BY:
CHECKED BY:
PROJECT NUMBER:
TITLE S
d CODS Sl
AO
THE5E DRAWINGS ARE GI'
AND SHALL BE USED ONLY
AGREEi" IEN'
PETERSON ARCHI'
NO OTHER U5E OR DUPLIC
WITHOUT THE PRIOR WRI
PETERSON AIRC41'
ALL OTHER COPYRIGHT
RIGHTS ARE HEREBY SPEC