HomeMy WebLinkAbout03030112.9EXISTING BUILDING COPING
MTL, COPING TO REMAIN
2X TREATED
BLOCKING
AT EXISTING BUILDING
PRE-ENGINEERED MTL.
BUILDING FRAME
r,vvuNl IVr,� VL11-1�\V
3-5/8' MTL. STUD LUALL
STUDS AT 16' OL. FACE
'6 BAR AT 48' O.G. LU/ 5/8' GYP. BD.
VERT. RErNF. °
GROUT FULL >i
{ 10RT. JOINT
REINF. AT 16' O.G.
/` I^ CI AC
SECOND FLOOR
ELEv. III' -6'
8' C.M.U. WALL JOISTS BY
BUILDING SUPPLIER
8' C.M.U. WALL
(BEYOND)
3-5/8' MTL. STUD LUALL
STUDS AT 16' O.C. FACE
LU/5/8' GYP. BD.
(2) 4' PRECAST
CONC. LINTELS
LU/ (2)'5 EA.
ALUM. STOREFRONT
DOOR AND SIDELITE
ASSEMBLY
WALL SECTION
EXPANSION JOINT ' SCALE: 3/4" = I' -O"
CONC. STOOP
CONC. SLAB
CONC. PIER
(BEYOND)
8' GMU
FOUNDATION IUALL
2'-f>EREIMETER
INSULATION
-- CONC. FOOTING
SEEFOUNDATION DUJ35