HomeMy WebLinkAbout03030112.13POWER PLAN - SECOND FLOOR
SCALE: 1/8' = 1'-0'
SYMBOLS LEGEND
EMERGENCY LIGHT WITH LIGHTED EXIT SIGN MOUNTED 18- BELOW
FINISHED CEILING LEVEL, UNLESS OTHERWISE NOTED.
EMERSENCY LIGHT WITH BATTERY BACK-UP. VERIFY FINAL LOCATION
WITH OWNER (TYPICAL)
0 I EXIT LIGHT
® I SUPPLY AIR DIFUSER REFER TO MECHANICAL DRAWNG5 FOR SIZE
AND LOCATION. (TYPICAL)
IRETURN AIR GRILL. REFER TO MECHANICAL DRAWINGS FOR SIZE
AND LOCATION. (TYPICAL)
ICEILING MOUNTED EXHAUST FAN.
I SINGLE POLE SWITCH 20A -120V s 4'-0' AFF.
TO I THERMOSTAT 9 60' AFF.
Q TELEPHONE JACK is 14' AFF. UNLESS NOTED OTHERWISE. J -BOX
4 RACEWAY ABOVE CEILING:
- DATA DROP s 14' AFF. UNLESS NOTED OTHERWISE. J -BOX 4 RACEWAY
ABOVE CEILING.
o I EXISTING ELECTRICAL PANEL
E)— SINGLE OUTLET AND T.Y. CABLE JACK s 2' BELOW CEILING.
5 4.5 4 3 2 1.3 1 DUPLEX OUTLET 2OA-120v s 14' AFF, UNLESS NOTED OTHERWISE.
3-04 CONDUITS W/
4-500 MCM EA.
I POWER PLAN -FIRST FLOOR
\-� I SCALE: 1/8' = I'-0'
I' CONDUIT
W/ 3-%
RI I R
m *2
2-1/2' CONDUIT
W/ 4-3/0
2-1/2' CONDUIT
W/ 4-3/0
A B
UTILITY MDP 200 AMP 200 AMP EXISTING:
TRANSFORMER CT 1200 AMP 3P4W 31=4W 800 AMP
CABINET O 3P4W 120/208V 120/208V 3P4W
F-7 120/208V 120/206V
UTILITY METERING
3 -1'4 CONDUIT
BY UTILITY
ELECTRICA
NO SCALE
GROUND INCs
PER NEC:
2002
L RISER
2-04 CONDUITS
W/ 4-500MCM EA -
DIAGRAM
�GFI I DUPLEX OUTLET W/ GROUND FAULT INTERRUPTER
I COUNTER HEIGHT DUPLEX OUTLET
�1G I DUPLEX OUTLET W/ ISOLATED GROUND
:0220V 1 220V DUPLEX CONVENIENCE OUTLET o 14' AFF. UNLESS NOTED OTHERWISE
® I DUPLEX OUTLET W/ WEATHERPROOF COVER AND GROUND FAULT
NTERRUPTER s 14' AFF.
0 I QUADRAPLEX OUTLET - 14' A.F.F. UNLESS NOTED OTHERWISE
Q I JUNCTION BOX
I TIME CLOCK
NOTES
THIS DRAWING REPRESENTS THE GENERAL SCOPE OF THE PROJECT BUT DOES NOT NECESSARILY
INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF
THE REQUIREMENTS OF THE CONTRACT. THE TRADE CONTRACTORS SHALL PERFORM SUCH
SERVICES ABC) FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION OF THE PROJECT.
ANY DEVICES NOT 5HOl1N (I.E. FANS OR SPEAKERS) SHALL BE CENTERED N CEILING TILES AND
BETWEEN LIGHTS N EACH DIRECTION.
FOR SYMBOLS 54� IN THE LEGEND BUT DO NOT SHOW ON THE DRAWING MAY BE RELATED TO
OTHER D151PLINES AND MAY SHOW UP ON OTHER DRAWINGS. REFER TO THE MECHANICAL AND
ELECTRICAL DRAWINGS.
O
Z
O
Q
wMATTINGL
C0RP0RAT10
10150 LANTERN ROAD, SUM 10C
FISHERS, INDIANA 46038
317-577-9688
U
z
CONSTRUCTION DRAIUIr
OCTOBER Il, 2002
REVISIONS
REVISION
1 DATE
jj'REVISION
2 DATE
0 RRETF N
4 RDAEVt�SION
QRREEV✓ISON
PLOT DATE:
DRAWN BY:
CHECK BY D PETE
PROJECT MJMBER: 02 -
ELECTRICAL
POWER PLAN
E101
THESE DRAWING5 ARE GIVEN IN CONFID,
AND SHALL 5E U5ED ONLY IN PURSUANT
AGREEMENT WITH
PETERSCIN ARCHITECTURE, RC
NO OTHER U5E OR DUPLICATION MAY hE
WITHOUT THE PRIOR WRITTEN CON5ENT
PETERSON ARCHITECTURE, RC
ALL OTHER COPYRIGHT AND COI'1t'"ON
RIGHTS ARE HEREBY 5PECIFICALLY RESE