HomeMy WebLinkAbout17080023.3DEMOLITION LEGEND
EXISTING TO BE REMOVED EXISTING TO REMAIN
------ WALL
WALL
=----= PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL
DOOR AND FRAME
WINDOW/ SIDELIGHT
'- CEILING GRID AND
TILES, 2'x4'
CEILING GRID AND
TILES, 2'x2'
�y SUPPLY AIR DIFFUSERS
c=sac3
rf— -- LIGHT FIXTURE,
L FLUORESCENT, 2'x4'
r 1 LIGHT FIXTURE,
11 11
L.J FLUORESCENT, 2'x2'
LIGHT FIXTURE, CAN
-----1 LIGHT FIXTURE, LINEAR
PENDANT
rN LIGHT FIXTURE, SCONCE';
LIGHT FIXTURE,
PENDANT
LIGHT SWITCH
Q`^ EXIT LIGHT
:�t -q° ELECTRIC OUTLET(S)
r
lb" rpit J"
DATA OR
(� COMMUNICATION
OUTLET
DOOR AND FRAME
—7 -� - {-
}� WINDOW / SIDELIGHT
NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN
GOOD CONDITION.
DEMOLITION PLAN NOTES
D01 REMOVE EXISTING RECEPTACLE AS SHOWN. PATCH WALL AND
PREPARE FOR NEW FINISHES AS REQUIRED.
D02 REMOVE EXISTING FLOOR CORE AND INFILL AS REQUIRED TO
MAINTAIN BUILDING CONSTRUCTION TYPE. PREPARE FLOOR FOR
NEW FINISHES AS REQUIRED.
AREA NOT IN CONTRACT
❑ AREA OF WORK
DEMOLITION PLAN
0 2' 4' 8' 16
WALL TYPES
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE W2 UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN
RESTROOM AND/OR SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
W1 STANDARD WALL
3%8 " METAL STUDS AT 16" O.C.;
ONE LAYER OF V8" TYPE "X" GYPSUM BOARD - =
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING
WALL WITH INSULATION
3%8 " METAL STUDS AT 16" O.C.;
ONE LAYER OF %8" TYPE "X" GYPSUM BOARD = ---------
EACH SIDE,-
EXTEND
IDE;EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
W3 DEMISING WALL TO DECK WITH INSULATION
3%" METAL STUDS AT 16" O.C.; -
-I
ONE LAYER OF %" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF DECK;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" SOUND BATT INSULATION EACH
SIDE OF WALL ABOVE CEILING.
TYPICAL WAL
METAL STUD
EXISTING WIN
MULLION
WALL
THICKNESS
7�_
PRE -FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
LINE OF EXISTING WINDOW
SILL COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
LVx Q-1
1 WALL AT MULLION DETAIL
-- A' NOT TO SCALE
ARCHITECTURAL LEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
W?
WALL
N
PARTIAL HEIGHT WALL
®
WINDOW / SIDELIGHT
WALL
® PARTIAL HEIGHT WALL
�Q WINDOW / SIDELIGHT
5DOOR AND FRAME
## (SEE DOOR SCHEDULE) ## DOOR AND FRAME
NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS.
GENERAL NOTES
1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.
PLAN NOTES
ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
A01 STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS.
PROVIDE PLYWOOD PHONE BOARD, 4'x8'x4", PAINTED WITH FIRE
A02 RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY
LOCATION WITH TENANT PRIOR TO INSTALLATION.
A03 NEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY
CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED
ACCORDING TO NFPA 10.
E
OFFICE FRONT WALL TO EXTEND TO 8'-4" A.F.F. DESIGN INTENT IS
4 FOR THIS WALL TO EXTEND TO UNDERSIDE OF CEILING GRID IN THIS
AREA. SEE SHEET A 121 FOR MORE INFORMATION.
A05 OFFICE DIVIDING WALL TO EXTEND TO 8'-0" A.F.F. DESIGN INTENT IS
FOR THIS WALL TO EXTEND TO UNDERSIDE OF CEILING GRID IN THIS
AREA. SEE SHEET A 121 FOR MORE INFORMATION.
A06 CONFIRM IF EXISTING WALL CONSTRUCTION MATCHES WALL TYPE
W3. IF NOT, ALTER WALL AS REQUIRED SO THAT IT MATCHES WALL
TYPE W3.
PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE
P01 AND VENT PIPING FOR SINKS.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING.
PROVIDE WATER LINE FOR COFFEE AND REFRIGERATOR. CONFIRM
P02 LOCATION WITH TENANT.
AREA NOT IN CONTRACT
❑ AREA OF WORK
ARCHITECTURAL PLAN
0 2' 4' 8' 16'
moi•
C) F
_ O
N '0 O U
(D -,,I- o
v> Z
ViCo70
0` Q O
U
CD C N
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINE
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOT
DESIGN, INC.. AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, C
IN PART: WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
N
0
0
�Z
W
H
�O
v)
�
�
Z<
QIn
Q
Z
N
Lu
z
O
I-
Uz
.Qo
-ry
p
Lu
UJ
Z
o
0.1
ISSUE
DATE DESCRIPTION_
07.24.17 REVIEW SET
07.27.17 PERMIT SET
REVISIONS
MARK DATE DB IDESCRIPTIC
�`,`,11N1111111f/I�j��
O JAN r e aDy���i
No
1 =� AR10700017�
n ?,� STATE OF
TY P.
'•.FRED A�� �►��
PROJECT NUMBER
2017.245
PROJ. MGR DRAWN B'
ACM SLF
6TH FLOOR
DEMOLITION PLAN
ARCHITECTURAL
FLOOR PLAN
A111