Loading...
HomeMy WebLinkAbout17080023.3DEMOLITION LEGEND EXISTING TO BE REMOVED EXISTING TO REMAIN ------ WALL WALL =----= PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL DOOR AND FRAME WINDOW/ SIDELIGHT '- CEILING GRID AND TILES, 2'x4' CEILING GRID AND TILES, 2'x2' �y SUPPLY AIR DIFFUSERS c=sac3 rf— -- LIGHT FIXTURE, L FLUORESCENT, 2'x4' r 1 LIGHT FIXTURE, 11 11 L.J FLUORESCENT, 2'x2' LIGHT FIXTURE, CAN -----1 LIGHT FIXTURE, LINEAR PENDANT rN LIGHT FIXTURE, SCONCE'; LIGHT FIXTURE, PENDANT LIGHT SWITCH Q`^ EXIT LIGHT :�t -q° ELECTRIC OUTLET(S) r lb" rpit J" DATA OR (� COMMUNICATION OUTLET DOOR AND FRAME —7 -� - {- }� WINDOW / SIDELIGHT NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN GOOD CONDITION. DEMOLITION PLAN NOTES D01 REMOVE EXISTING RECEPTACLE AS SHOWN. PATCH WALL AND PREPARE FOR NEW FINISHES AS REQUIRED. D02 REMOVE EXISTING FLOOR CORE AND INFILL AS REQUIRED TO MAINTAIN BUILDING CONSTRUCTION TYPE. PREPARE FLOOR FOR NEW FINISHES AS REQUIRED. AREA NOT IN CONTRACT ❑ AREA OF WORK DEMOLITION PLAN 0 2' 4' 8' 16 WALL TYPES NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE W2 UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. W1 STANDARD WALL 3%8 " METAL STUDS AT 16" O.C.; ONE LAYER OF V8" TYPE "X" GYPSUM BOARD - = EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING WALL WITH INSULATION 3%8 " METAL STUDS AT 16" O.C.; ONE LAYER OF %8" TYPE "X" GYPSUM BOARD = --------- EACH SIDE,- EXTEND IDE;EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W3 DEMISING WALL TO DECK WITH INSULATION 3%" METAL STUDS AT 16" O.C.; - -I ONE LAYER OF %" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" SOUND BATT INSULATION EACH SIDE OF WALL ABOVE CEILING. TYPICAL WAL METAL STUD EXISTING WIN MULLION WALL THICKNESS 7�_ PRE -FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT LVx Q-1 1 WALL AT MULLION DETAIL -- A' NOT TO SCALE ARCHITECTURAL LEGEND NEW CONSTRUCTION EXISTING TO REMAIN W? WALL N PARTIAL HEIGHT WALL ® WINDOW / SIDELIGHT WALL ® PARTIAL HEIGHT WALL �Q WINDOW / SIDELIGHT 5DOOR AND FRAME ## (SEE DOOR SCHEDULE) ## DOOR AND FRAME NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. GENERAL NOTES 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. PLAN NOTES ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS A01 STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. PROVIDE PLYWOOD PHONE BOARD, 4'x8'x4", PAINTED WITH FIRE A02 RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. A03 NEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. E OFFICE FRONT WALL TO EXTEND TO 8'-4" A.F.F. DESIGN INTENT IS 4 FOR THIS WALL TO EXTEND TO UNDERSIDE OF CEILING GRID IN THIS AREA. SEE SHEET A 121 FOR MORE INFORMATION. A05 OFFICE DIVIDING WALL TO EXTEND TO 8'-0" A.F.F. DESIGN INTENT IS FOR THIS WALL TO EXTEND TO UNDERSIDE OF CEILING GRID IN THIS AREA. SEE SHEET A 121 FOR MORE INFORMATION. A06 CONFIRM IF EXISTING WALL CONSTRUCTION MATCHES WALL TYPE W3. IF NOT, ALTER WALL AS REQUIRED SO THAT IT MATCHES WALL TYPE W3. PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE P01 AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. PROVIDE WATER LINE FOR COFFEE AND REFRIGERATOR. CONFIRM P02 LOCATION WITH TENANT. AREA NOT IN CONTRACT ❑ AREA OF WORK ARCHITECTURAL PLAN 0 2' 4' 8' 16' moi• C) F _ O N '0 O U (D -,,I- o v> Z ViCo70 0` Q O U CD C N THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINE HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOT DESIGN, INC.. AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, C IN PART: WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. N 0 0 �Z W H �O v) � � Z< QIn Q Z N Lu z O I- Uz .Qo -ry p Lu UJ Z o 0.1 ISSUE DATE DESCRIPTION_ 07.24.17 REVIEW SET 07.27.17 PERMIT SET REVISIONS MARK DATE DB IDESCRIPTIC �`,`,11N1111111f/I�j�� O JAN r e aDy���i No 1 =� AR10700017� n ?,� STATE OF TY P. '•.FRED A�� �►�� PROJECT NUMBER 2017.245 PROJ. MGR DRAWN B' ACM SLF 6TH FLOOR DEMOLITION PLAN ARCHITECTURAL FLOOR PLAN A111