Burgess Mechanical Corporation �urgifess
12220 Southeastern Ave.
Indianapolis, IN 46259
(317)862-4395
jb@burgessmechanical.com
www.burgessmechanical.com
INVOICE
BILL TO INVOICE# 17-093
City of Carmel Utilities DATE 07/10/2017
9609 Hazel Dell Parkway DUE DATE 07/10/2017
Indianapolis, IN 46280 TERMS Due on receipt
DATE ACTIVITY AMOUNT
02/28/2017 Service Work T&M 445.00
Service call on boiler down at Waste Water Treatment Plant. Checked
Burnham boiler for cause of flame failure. Found gas continues to burn
around burner head causing Honeywell Flame Controller to lock out on flame
detected when main valves are shut. Removed part of the gas train for
inspection and found pile of rust, etc in burner head. Will need to remove the
rest of the piping at burner head for more cleaning and inspection.
02/28/2017 Trip Charge 80.00
Truck/Fuel Charge
03/01/2017 Service Work T&M 267.00
Removed all wiring and burner controls from burner housing. Removed
housing and burner head from boiler for cleaning and inspection. Found
burner head gas ring was stopped up with debris. Removed and cleaned all
dirt from inside burner head. May also want to replace high gas pressure
switch. Will return to start putting the burner back together.
03/01/2017 Materials for Jobs 31.86
Furnace/Boiler Cement
03/01/2017 Trip Charge 80.00
Truck/Fuel Charge
03/22/2017 Service Work T&M 445.00
Started putting Burnham boiler back together. Noted gas train has no hand
shutoff valves. Will return to finish after valves are installed. Cannot safely
restart burner without the valves being replaced.
03/22/2017 Trip Charge 80.00
Truck/Fuel Charge
04/06/2017 Service Work T&M 356.00
Put burner, gas train and wiring all back together. Will return on Tuesday to
fire boiler up and place back in service.
04/06/2017 Trip Charge 80.00
Truck/Fuel Charge
04/11/2017 Service Work T&M 400.50
Tried to fire burner on methane gas and found no gas pressure going into gas
train. Will return to fire after problem is found and corrected.
DATE ACTIVITY AMOUNT
04/11/2017 Trip Charge 80.00
Truck/Fuel Charge
04/20/2017 Service Work T&M 356.00
Arrived to start Burnham boiler back up on methane gas after gas supply line
was cleaned out. Found one of the main fuel valves stuck 100%open.
Recommend installing new valves. Will return to fire burner after valves are
installed.
04/20/2017 Trip Charge 80.00
Truck/Fuel Charge
06/06/2017 Service Work T&M 712.00
Started burner back up after both fuel valves were replaced. Ran low through
high fire with minor combustion adjustments. Also test fired on natural gas.
06/06/2017 Equipment/Tool Charge 75.00
Analyzer
06/06/2017 Trip Charge 80.00
Truck/Fuel Charge
06/07/2017 Service Work T&M 623.00
Started boiler up on methane gas and placed back on line. Verified operating
and safety controls are working properly.
06/07/2017 Trip Charge 80.00
Truck/Fuel Charge