Loading...
HomeMy WebLinkAbout314774 08/15/17 9'y'� ��'`'� CITY OF CARMEL, INDIANA VENDOR: 00351470 ONE CIVIC SQUARE BURGESS MECHANICAL CHECK AMOUNT: $*****4,351.36* =q CARMEL, INDIANA 46032 12220 SOUTHEASTERN AVE CHECK NUMBER: 314774 ,yiroN. INDIANAPOLIS IN 46259 CHECK DATE: 08/15/17 DEPARTMENT ACCOUNT PO NUMBER INVOICE NUMBER AMOUNT DESCRIPTION 651 5023990 17-093 4,351.36 OTHER EXPENSES f i 3 yd Wmm 7, O W W P a # Q aq N M O .1 4A- M M 4A- 4A, Q O } N M u i a ro s J z N O O tD C = O O > f ^i W � ul chi � Q Zicpp Ln N O a >° co � S S Burgess Mechanical Corporation �urgifess 12220 Southeastern Ave. Indianapolis, IN 46259 (317)862-4395 jb@burgessmechanical.com www.burgessmechanical.com INVOICE BILL TO INVOICE# 17-093 City of Carmel Utilities DATE 07/10/2017 9609 Hazel Dell Parkway DUE DATE 07/10/2017 Indianapolis, IN 46280 TERMS Due on receipt DATE ACTIVITY AMOUNT 02/28/2017 Service Work T&M 445.00 Service call on boiler down at Waste Water Treatment Plant. Checked Burnham boiler for cause of flame failure. Found gas continues to burn around burner head causing Honeywell Flame Controller to lock out on flame detected when main valves are shut. Removed part of the gas train for inspection and found pile of rust, etc in burner head. Will need to remove the rest of the piping at burner head for more cleaning and inspection. 02/28/2017 Trip Charge 80.00 Truck/Fuel Charge 03/01/2017 Service Work T&M 267.00 Removed all wiring and burner controls from burner housing. Removed housing and burner head from boiler for cleaning and inspection. Found burner head gas ring was stopped up with debris. Removed and cleaned all dirt from inside burner head. May also want to replace high gas pressure switch. Will return to start putting the burner back together. 03/01/2017 Materials for Jobs 31.86 Furnace/Boiler Cement 03/01/2017 Trip Charge 80.00 Truck/Fuel Charge 03/22/2017 Service Work T&M 445.00 Started putting Burnham boiler back together. Noted gas train has no hand shutoff valves. Will return to finish after valves are installed. Cannot safely restart burner without the valves being replaced. 03/22/2017 Trip Charge 80.00 Truck/Fuel Charge 04/06/2017 Service Work T&M 356.00 Put burner, gas train and wiring all back together. Will return on Tuesday to fire boiler up and place back in service. 04/06/2017 Trip Charge 80.00 Truck/Fuel Charge 04/11/2017 Service Work T&M 400.50 Tried to fire burner on methane gas and found no gas pressure going into gas train. Will return to fire after problem is found and corrected. DATE ACTIVITY AMOUNT 04/11/2017 Trip Charge 80.00 Truck/Fuel Charge 04/20/2017 Service Work T&M 356.00 Arrived to start Burnham boiler back up on methane gas after gas supply line was cleaned out. Found one of the main fuel valves stuck 100%open. Recommend installing new valves. Will return to fire burner after valves are installed. 04/20/2017 Trip Charge 80.00 Truck/Fuel Charge 06/06/2017 Service Work T&M 712.00 Started burner back up after both fuel valves were replaced. Ran low through high fire with minor combustion adjustments. Also test fired on natural gas. 06/06/2017 Equipment/Tool Charge 75.00 Analyzer 06/06/2017 Trip Charge 80.00 Truck/Fuel Charge 06/07/2017 Service Work T&M 623.00 Started boiler up on methane gas and placed back on line. Verified operating and safety controls are working properly. 06/07/2017 Trip Charge 80.00 Truck/Fuel Charge Delinquent accounts are subject to reasonable legal and collection BALANCE DUE $4,351 .36 fees.