HomeMy WebLinkAbout17070018.221 SECOND FLOOR PLAN - HVAC "M101 1/8" = V-0" 7 I= 0' 4' 8' 16' GENERAL PLAN NOTES 1. BRANCH DUCTS TO SUPPLY REGISTERS AND DIFFUSERS SHALL BE SAME SIZE AS REGISTER AND DIFFUSER NECK/DUCT CONNECTION UNLESS OTHERWISE NOTED. 2. DIFFUSERS AND GRILLES SHALL BE UNIFORMLY MOUNTED NO LOWER THAN THE BOTTOM ELEVATION OF THE LAY -IN CEILING CLOUDS. 3. ALL EXPOSED DUCTWORK, DIFFUSERS, GRILLES, ETC. IN AREAS WITHOUT CEILING SHALL BE PAINTED BLACK. COORDINATE WITH ARCHITECTURAL CEILING DRAWINGS. 4. ALL EXPOSED DUCTWORK SHALL BE SHEET METAL. NO FLEXIBLE DUCTWORK SHALL BE ALLOWED IN EXPOSED AREAS. FLEXIBLE DUCTWORK SHALL ONLY BE USED ABOVE LAY -IN CEILING AREAS WHERE DUCTWORK WILL NOT BE EXPOSED. 5. COORDINATE EXACT LOCATION OF CEILING DIFFUSERS, REGISTERS AND GRILLES WITH LIGHTING INSTALLATION. ADJUST EXACT LOCATIONS AS NECESSARY. PLAN NOTES 0 REMOVE EXPANDED METAL GRILLE FROM OF EXISTING LINED 60 x 18 (VERIFY SIZE) RETURN DUCT AND EXTEND INTO NEW COMMONS AREA AS NECESSARY TO ACCOMMODATE NEW CONSTRUCTION. COVER OPEN END WITH EXPANDED METAL GRILLE. O2 RESET MAXIMUM AIRFLOW SETTING ON TERMINAL VAV UNIT FROM 340 CFM TO 440 CFM. MINIMUM/HEATING SETTING SHALL REMAIN UNCHANGED OCONNECT NEW 10 x 10 RETURN AIR BRANCH DUCT TO EXISTING 60 x 18 (VERIFY SIZE) RETURN MAIN AND EXTEND INTO NEW ELEVATOR LOBBY AREA. PROVIDE VOLUME DAMPER AND FIRE DAMPER IN BRANCH DUCT. COVER OPEN END WITH EXPANDED METAL GRILLE. BALANCE TO 400 CFM. OLINED 12 x 12 TRANSFER DUCT BETWEEN TRANFER GRILLES. OLINED 8 x 8 TRANSFER DUCT BETWEEN TRANFER GRILLES. 1�6 RELOCATE EXISTING THERMOSTAT SERVING EXISTING VAV TERMINAL UNIT LISTED TO THIS LOCATION. EXTEND WIRING AS NECESSARY, ALL WIRING SHALL BE CONCEALED IN WALL/CHASE OR ABOVE CEILINGS. OEXTEND EXISTING LINED DUCTWORK TO COMMON AREA AS SHOWN. FIELD MEASURE DUCT SIZE. COVER OPEN EXPOSED END WITH EXPANDED METAL GRILLE. OEXTEND EXISTING LINED TRANSFER DUCTWORK WITH LINED ELBOW AS SHOWN. FIELD MEASURE DUCT SIZE. COVER OPEN EXPOSED END WITH EXPANDED METAL GRILLE. O9 INSTALL LINED ELBOW TRANSFER DUCT AS SHOWN BETWEEN MEETING ROOM AND ADJACENT COMMON AREA. DUCT SHALL BE SAME SIZE AS EXISTING LINED TRANSFER DUCT THROUGH WEST WALL (SEE NOTE #8), FIELD VERIFY. COVER OPEN EXPOSED ENDS WITH EXPANDED METAL GRILLE. 10 EXTEND EXISTING LINED TRANSFER DUCTWORK WITH LINED ELBOW AS SHOWN. TRANSITION TO LINE 14 x 14 AND EXTEND TO COMMON AREA. FIELD MEASURE EXISTING DUCT SIZE. COVER OPEN EXPOSED END WITH EXPANDED METAL GRILLE. 11 RESET MAXIMUM AIRFLOW SETTING ON TERMINAL VAV UNIT FROM 250 CFM TO 300 CFM. MINIMUM/HEATING SETTING SHALL REMAIN UNCHANGED ?2 RESET MAXIMUM AIRFLOW SETTING ON TERMINAL VAV UNIT FROM 350 CFM TO 440 CFM. MINIMUM/HEATING SETTING SHALL REMAIN UNCHANGED DIFFUSER, REGISTER AND GRILLE SCHEDULE EXAMPLE MARK MANUFACTURER MODEL NO. CORE STYLE SIZE L"x W" MATERIAL FRAME ROUND NECK SIZE REMARKS SD1 TITUS TDC 4 -WAY 24 x 24 ALUMINUM LAY -IN 6" DIA. SQUARE CEILING DIFFUSER SD2 TITUS TDC 4 -WAY 24 x 24 ALUMINUM LAY -IN 8" DIA. SQUARE CEILING DIFFUSER SD3 TITUS TDC 4 -WAY 24 x 24 ALUMINUM LAY -IN 10" DIA. SQUARE CEILING DIFFUSER SR1 TITUS 30OF LOUVERED 8 x 6 ALUMINUM SURFACE MOUNT DOUBLE DEFLECTION, 3/4" SPACING, OPPOSED BLADE DAMPER SR2 TITUS 30OF LOUVERED 12 x 6 ALUMINUM SURFACE MOUNT - DOUBLE DEFLECTION, 3/4" SPACING, OPPOSED BLADE DAMPER TG1 TITUS 35OF LOUVERED 8 x 8 ALUMINUM SURFACE MOUNT 35' DEFLECTION, 3/4" SPACING TG2 TITUS 350F LOUVERED 12 x 12 ALUMINUM SURFACE MOUNT 35' DEFLECTION, 3/4" SPACING GENERAL NOTES: 1. ALL DIFFUSERS, GRILLES AND REGISTERS WITHIN LAY -IN CEILING GRID SHALL HAVE WHITE FINISH UNLESS OTHERWISE NOTED. WOOL Architecture I Eng 7635 Interacti Suite 100 Indianapolis, 317.299.7500 e A Pubh( Partr � I Q v City 0i Inc V) J Z 0 !W v! W LL 0/ ry L.L. w Q W LL Cl)o REV DATE DE 02/28/2017 160% O 1 1 03/13/2017 175% PI 1 1 04/04/2017 1 BID AN ww A ME 00%■Oft n 10%rmwRM■SNIP Arm Proj. No.: Date: 61 M►Framm SECONE HVAC Q